NOTES: ALL OUTLETS IN THE BASEMENT MUST BE GFCI

· · ·

TW2036

TW2036

·

TW2036

BASEMENT

TW2036

TW2036

TW2036

· ·

ALL EXTERIOR OUTLETS MUST BE GFCI AND WATERPROOFED ALL OUTLETS IN BATHROOMS MUST BE GFCI ALL OUTLETS IN KITCHENS MUST BE GFCI CABLE/WIFI MUST BE RAN SEPERATE FROM ELECTRIC LINES TO AVOID INTERFENCE/RECEPTION ISSUES STOVE REQUIRES A DESIGNATED 220V LINE SMOKE/CARBON MONOXIDE COMBO DETECTORS MUST BE HARD WIRED TOGETHER IN A SERIES CONNECTION


ALL EXTERIOR OUTLETS MUST BE GFCI AND IN WATER PROOF CASING

BATH

BATH

KITCHEN

TW2640

TW2640

TW2636

· · · ·

· ·

CLOSET CLOSET

220 VOLT DESIGNATED CIRCUIT

CLOSET

BEDROOM BEDROOM

TW2646

TW2046

TW2646 150 AMP ELECTRIC PANEL ALL EXTERIOR OUTLETS MUST BE GFCI AND IN WATER PROOF CASING

TW2646 TW2646

TW3046

TW3046

LIVING ROOM

ALL EXTERIOR OUTLETS MUST BE GFCI AND WATERPROOFED ALL OUTLETS IN BATHROOMS MUST BE GFCI ALL OUTLETS IN KITCHENS MUST BE GFCI CABLE/WIFI MUST BE RAN SEPERATE FROM ELECTRIC LINES TO AVOID INTERFENCE/RECEPTION ISSUES STOVE REQUIRES A DESIGNATED 220V LINE SMOKE/CARBON MONOXIDE COMBO DETECTORS MUST BE HARD WIRED TOGETHER IN A SERIES CONNECTION


BATH

BATH

KITCHEN

TW2640

TW2640

TW2636

CLOSET CLOSET

CLOSET

BEDROOM BEDROOM

TW2646

TW2646

TW2046

TW2646 TW2646

TW3046

TW3046

LIVING ROOM


2 X 10 JOIST @ 16" O.C.

2 X 10 JOIST @ 16" O.C.

2 X 10 JOIST @ 16" O.C.

2 X 10 JOIST @ 16" O.C.

2 X 10 JOIST @ 16" O.C.

TW2036

TW2036

TW2036

TW2036

2 X 10 JOIST @ 16" O.C.

BASEMENT

(2) 2X12 GIRDER

2 X 10 JOIST @ 16" O.C.

(2) 2X12 GIRDER

2 X 10 JOIST @ 16" O.C.

TW2036

TW2036

2 X 10 JOIST @ 16" O.C.

2 X 10 JOIST @ 16" O.C.

2 X 10 JOIST @ 16" O.C. DBL JOIST


TYPICAL ROOF: ARCH. ASPHALT SHINGLES 15# FELT PAPER 5 8"

CDX PLYWOOD SHEATHING 2 X 10 R.R @ 16 O.C.

MIN.

WATER & ICE SHEILD (TYP)

TYPICAL WALL:

VENTED SOFFIT

HORIZONTAL SIDING RIGID INSULATION TYVEK BLDG. WRAP

1 2"

CDX PLYWOOD SHEATHING 2X6 STUDS @ 24" O.C. 5 21 " R-19 BATT INSULATION 5 8

PLATE H.T.

1 2"

2" CORNER TRIM

GYPSUM BOARD VINYL SIDING (TYPICAL)


left

12X12 LOVRE

MIN.

TYPICAL ROOF: ARCH. ASPHALT SHINGLES 15# FELT PAPER

1X FASCIA BD.

TYPICAL WALL:

5 8"

CDX PLYWOOD SHEATHING 2 X 10 R.R @ 16 O.C. VENTED SOFFIT

HORIZONTAL SIDING 1 2" 1 2"

CDX PLYWOOD SHEATHING 2X6 STUDS @ 24" O.C. 5 21 " R-19 BATT INSULATION 5 8

2" CORNER TRIM PLATE H.T.

RIGID INSULATION TYVEK BLDG. WRAP

GYPSUM BOARD VINYL SIDING (TYPICAL)


TYPICAL ROOF: ARCH. ASPHALT SHINGLES 15# FELT PAPER 5 8"

CDX PLYWOOD SHEATHING 2 X 10 R.R @ 16 O.C.

TYPICAL WALL:

MIN.

1X FASCIA BD.

WATER & ICE SHEILD (TYP)

VENTED SOFFIT

1 2"

RIGID INSULATION TYVEK BLDG. WRAP

1 2"

CDX PLYWOOD SHEATHING 2X6 STUDS @ 24" O.C. 1 2

5 " R-19 BATT INSULATION 5 8

GYPSUM BOARD

PLATE H.T.

HORIZONTAL SIDING

2" CORNER TRIM VINYL SIDING (TYPICAL)


right

12X12 LOVRE

WATER & ICE SHEILD (TYP) 1X FASCIA BD.

TYPICAL WALL:

MIN.

TYPICAL ROOF: ARCH. ASPHALT SHINGLES 15# FELT PAPER 5 8"

CDX PLYWOOD SHEATHING 2 X 10 R.R @ 16 O.C. VENTED SOFFIT

1 2"

RIGID INSULATION TYVEK BLDG. WRAP

1 2"

CDX PLYWOOD SHEATHING 2X6 STUDS @ 24" O.C. 5 21 " R-19 BATT INSULATION 5 8

PLATE H.T.

PLATE H.T.

HORIZONTAL SIDING

2" CORNER TRIM

GYPSUM BOARD VINYL SIDING (TYPICAL)


R-VALUE OF BUILDING MATERIALS BUILDING MATERIAL INTERIOR TEMPERATURE INTERIOR AIR FILM 1/2" GYUPSUM BD/ PAPER OF BATT CDX PLYWOOD/EXTERIOR FACE OF BATT 3/8" POLYURETHANE INSULATION WRAP VINYL SIDING AIR FILM EXTERIOR TEMPERATURE TOTAL

R-VALUE 0 0.70 0.50 19.00 0.60 2.25 0.61 0.20 23.86

TOTAL CHANGE IN )°F(TEMPERATURE 70 0 70.00

TEMPERATURE )° F(CHANGE OF MATERIAL 0.00 2.05 3.52 59.26 61.02 67.62 69.41324392 70.00 N/A

ACTUAL TEMPERATURE (°F) 70 67.95 66.48 10.74 8.98 2.38 0.59 70.00 N/A


67.26


CONTINUOUS RIDGE VENT 2 X 12 RIDGE 12

7

2 X 6 COLLAR TIES @ 32" O.C.

TYPICAL ROOF: WATER & ICE SHEILD (TYP)

ATTIC

MIN.

TYPICAL CEILING

ARCH. ASPHALT SHINGLES 15# FELT PAPER

2X8 C.J. @ 16' O.C 6" R-19 BATT INSULATION 1 2"

1X FASCIA BD.

5 8"

CDX PLYWOOD SHEATHING 2 X 10 R.R @ 16 O.C.

GYPSUM BOARD

VENTED SOFFIT

PLATE H.T.

HORIZONTAL SIDING 1 2"

RIGID INSULATION TYVEK BLDG. WRAP

1 2"

CDX PLYWOOD SHEATHING 2X6 STUDS @ 24" O.C.

PLATE H.T.

TYPICAL WALL:

LIVING ROOM

KITCHEN

5 21 " R-19 BATT INSULATION 5 8

2 X 10 BOX BEAM

GYPSUM BOARD (2) 2 X 6 SILL PLATE 1 2"

MIN.

GRADE

TYPICAL FLOOR: 3 4" 3 4"

PLYWOOD SUBFLOOR

HARDWOOD FLOOR 2X10 F.J. @ 16" O.C. 6" R-19 BATT INSULATION

(2) 2 X 12 GIRDER BOILER AND HW ROOM: 5 8

CONTINUOUS DBL. GYPSUM BOARD AND FIRE BLANKET INSULATION IN CEILING

3 21 " Ø STD. STL. LALLY COLUMN ON 2'-0" X 2'-0" X 1'-0" D. CONCRETE FOOTING

Ø ANCHOR BOLT @ 4'-0" O.C.

TYPICAL CEILING 1 2"

GYPSUM BOARD

8" POURED CONCRETE FOUNDATION WALL ON 16" X 8" D CONCRETE FOOTING

BASEMENT EXPANSION JOINT (CONTINUOUS) 4" CONCRETE SLAB APPLIED WATERPROOFING 4 MILL POLY VAPOR BARRIER

4" GRAVEL & SAND MIX ON COMPACTED EARTH


Mep portfolio  