Page 1


INDEX PROFILE............................................................................................................... 03 TEMPERATURE CONTROL UNITS................................................................ 04 WATER CIRCULATION 120℃, 140℃, 160℃, 180℃........................... 06 OIL CIRCULATION 200℃, 250℃, 300℃................................................. 08 CHILLERS............................................................................................................ 10




PROFILE EXIST WITH THE AMBITITON TO BECOME A LEADING COMOANY WITHIN THE FILED OF THE TEMPERATURE-CONTROLLED FOR MORE THAN 20 YEARS’EXPERIENCE IN THIS FIELD. HAS BEEN DEVELOPING SPECIFIC SKILLS TO MAKE SURE OUR CUSTOMERS IMPROVE PERFORMANCE AND INCREASE THE QUALITY OF THEIR PRODUCTS, AS WELL AS THE EFFECTIVENESS OF THEIR PROCESSES. TO ACHIEVE THIS GOAL,

, CONTINUES & FOCUS ON:

“CUSTOMER-IMPORTANT, PROFESSIONAL-SERVICE, TECHNOLOGY-INNOVATED, HIGH-END QUALITY”




TEMPERATURE CONTROL UNITS FEATURES 1.

ELECTRICAL CONTROL CABINET AND MACHINE BODY ARE SEPARATED, GOOD EFFECTIVE ISOLATION. 2. START-UP, FLUID-REFILLED AND AIR-DRAINED OF THE PIPING AUTOMATICALLY, AVOID OUT OF ORDER OF HEATER & PUMP. 3. PINPING IS MADE AS STAINLESS STEEL ONE STRUCTRE FORMATION, AVOID LEAKAGE. 4. BUILT-IN 4×4 MATERIAL SELECTORS, COMPACT DIMENSIONS. 5. JAPAN MADE“OMRON, YAMATAKE”P.I.D. INTERIOR COUNTED, ACCURACY:±0.5℃ (T/TS SERIES) ACCURACY:±0.1℃ (T/TAS SERIES/WATER TYPE ONLY) 6. MAJOR ELECTRIC PARTS ARE IMPORTED FROM JAPAN, EUROPE, SUCH AS: ”FUJI, OMRON, YAMATAKE, O.D.E.” 7. PUMP COMES FROM “SPECK, CALPEDA. TECO” 8. COMPLETE WITH SAFETY PROTECTION AND BREAK DOWN INDICATION SYSTEM, USER-FRIENDLY OPERATION. 9. TEMP. RANGE:120℃, 140℃, 160℃, 180℃ ⋯⋯⋯⋯⋯⋯ WATER CIRCULATION 200℃, 250℃, 300℃ ⋯⋯⋯⋯⋯⋯⋯⋯⋯ OIL CIRCULATION 10. MULTI-FUNCTION TEMPERATURE CONTROL UNITS (PATENT NO. TAIWAN 212252, M247811, CHINA ZL 02201464.0 ZL 200420006901.3) THE ADDITIONAL FUNCTIONS AS FOLLOW: A. STRONG POINT FOR TEMPERATURE DEVIATION WARNING WHEN THE DEVIATION BETWEEN TEMPERATURE OF SET-POINT AND ACTUAL VALUES IS OVER 2℃~4℃ (DEVIATION COULD SET BY USERS), WILL BE REVEALED BY ALARM & LAMP. B. STRONG POINT FOR COMPULSION COOLING BEFORE SHUT-DOWN, PUSH THE BUTTON, FLUID WILL BE COOLING COMPULSORY AUTOMATICALLY. MERIT:1. NO NEED TO SET TEMP. CONTROLLER WHILE START-UP UNDER THE SAME CONDITION. 2. NO NEED TO TURN OFF HEATER MANUALLY. C. STRONG POINT FOR DRAINING-FLUID AUTOMATICALLY MERIT:1. NO NEED TO ADJUST BALL VALVES MANUALLY, DRAINING-FLUID FROM MOULD DIRECTLY. 2. SAFE AND EASY TO OPERATE, NO FLUID-SPILLED WHILE TAKING OFF THE EXTERNAL PIPES.




SAFETY AND INDICATION ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆ ◆

MAIN POWER, NON-FUSE BREAKER. POWER, PHASE LACK & REVERSE PROTECTION. PROTECTION SWITCH FOR PROVE THE ELECTRIC LEAKAGE. (OIL TYPE) PUMP REVERSAL PROTECTING AND INDICATING LAMP. PUMP OVERLOAD PROTECTING AND INDICATING LAMP. FLUID SHORTAGE PROTECTING AND INDICATING LAMP. OVERHEAT PROTECTING AND INDICATING LAMP. BY-PASS CIRCULATION. BUZZER. COOLING COMPULSORY. (TS, TAS SERIES) TEMPERATURE DEVIATION ALARM AND INDICATING LAMP. (TS, TAS SERIES) SSR CONTROL. (TA, TAS SERIES) AFTER SHUT-DOWN, FLUID-DRANED AUTOMATICALLY. (TS SERIES)

OPTIONS AVAILABLE ◆ ◆ ◆ ◆ ◆ ◆ ◆

TIMER EXTERNAL THERMOCOUPLE FILTER ELECTRIC LEAKAGE CIRCUIT BREAKER INLET TEMPERATURE DIGITAL DISPLAY METER 3-PHASE VOLTAGE REALY (APR-3) TEFLON HOSE




WATER CIRCULATION 120℃ BYW-1210 Pump Characteristics

BYW-1220 Pump Characteristics

SPECIFICATION MODEL POWER SUPPLY (V/HZ/3Ø) MAX. TEMPERATURE (℃) MIN. TEMPERATURE (℃) TRANSFER MEDIUM HEATING CAPACITY (kW) COOLING CAPACITY (Kcal/hr) COOLING MODE ACCURACY OF TEMP. CONTROL (℃) PUMP NOMINAL POWER (kW) FLOW RATE MAX. (L/min) 50 HZ 60 HZ PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ MAX. POWER CONSUMPTION (kW) WATER SUPPLY PRESSURE (kg) COOLING WATER MAINS (Inch) OUTLET/INLET MAINS (Inch) DIMENSIONS L×W×H (mm) WEIGHT (kg)

BYW-1210T BYW-1220T BYW-1210TS BYW-1220TS AC220~440 50/60 120 40 WATER 9 6,000 DIRECT ±0.5 0.75 1.5 130 150 170 200 2.3 2.8 2.8 3.8 9.75 10.5 2.0 1/2 4×4 , 3/8 OR 1×1 , 3/4 690×300×530 46 50

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS. ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.



BYW-1210 TS BYW-1220 TS


WATER CIRCULATION 140℃ 160℃ 180℃ BYW-1410 Pump Characteristics

BYW-1615 Pump Characteristics BYW-1815 Pump Characteristics (2 in 1)

SPECIFICATION BYW-1410T BYW-1615T BYW-1815T BYW-1410TS BYW-1615TS BYW-1815T POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60 MAX. TEMPERATURE (℃) 140 160 180 MIN. TEMPERATURE (℃) 40 TRANSFER MEDIUM WATER HEATING CAPACITY (kW) 9 COOLING CAPACITY (Kcal/hr) 6,000 7,200 7,200 COOLING MODE DIRECT ACCURACY OF TEMP. CONTROL (℃) ±0.5 PUMP NOMINAL POWER (kW) 0.75 1.1 1.1 FLOW RATE MAX. (L/min) 50 HZ 130 50 50 60 HZ 170 60 60 PRESSURE MAX. (kg/cm2) 50 HZ 2.3 5.5 5.5 60 HZ 2.8 6.5 6.5 MAX. POWER CONSUMPTION (kW) 9.75 10.1 10.1 WATER SUPPLY PRESSURE (kg) 1.0 1.0 1.0 COOLING WATER MAINS (Inch) 1/2 OUTLET/INLET MAINS (Inch) 4×4 , 3/8 OR 1×1 , 3/4 DIMENSIONS L×W×H (mm) 690×300×530 730×300×750 730×300×750 WEIGHT (kg) 55 80 80

MODEL

BYW-1410 BYW-1615

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS. ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.




OIL CIRCULATION 200℃ BYO-2010 Pump Characteristics

BYO-2020 Pump Characteristics

(2 in 1)

SPECIFICATION MODEL POWER SUPPLY (V/HZ/3Ø) MAX. TEMPERATURE (℃) MIN. TEMPERATURE (℃) TRANSFER MEDIUM HEATING CAPACITY (kW) COOLING CAPACITY (Kcal/hr) COOLING MODE ACCURACY OF TEMP. CONTROL (℃) PUMP NOMINAL POWER (kW) FLOW RATE MAX. (L/min) 50 HZ 60 HZ PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ MAX. POWER CONSUMPTION (kW) WATER SUPPLY PRESSURE (kg) COOLING WATER MAINS (Inch) OUTLET/INLET MAINS (Inch) DIMENSIONS L×W×H (mm) WEIGHT (kg)

BYO-2010T BYO-2010TS

BYO-2020T BYO-2020TS

AC220~440 50/60 200 60 OIL 9 3,000 INDIRECT ±0.5 0.75 1.5 45 110 55 110 3.2 5.0 4.0 5.0 9.75 10.5 1.0 1/2 4×4 , 3/8 OR 1×1 , 3/4 730×300×750 70 75

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS. ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.



BYO-2010 BYO-2020


OIL CIRCULATION 250℃ 300℃ BYO-2520 Pump Characteristics

BYO-3015 Pump Characteristics

SPECIFICATION MODEL POWER SUPPLY (V/HZ/3Ø) MAX. TEMPERATURE (℃) MIN. TEMPERATURE (℃) TRANSFER MEDIUM HEATING CAPACITY (kW) COOLING CAPACITY (Kcal/hr) COOLING MODE ACCURACY OF TEMP. CONTROL (℃) PUMP NOMINAL POWER (kW) FLOW RATE MAX. (L/min) 50 HZ 60 HZ PRESSURE MAX. (kg/cm2) 50 HZ 60 HZ MAX. POWER CONSUMPTION (kW) WATER SUPPLY PRESSURE (kg) COOLING WATER MAINS (Inch) OUTLET/INLET MAINS (Inch) DIMENSIONS L×W×H (mm) WEIGHT (kg)

BYO-2520T BYO-3015T BYO-2520TS BYO-3015TS AC220~440 50/60 250 300 80 OIL 9 6,000 INDIRECT ±0.5 1.5 1.1 450 50 500 60 2.2 5.5 2.3 6.5 10.50 10.10 1.0 1/2 4×4 , 3/8 OR 1×1 , 3/4 890×400×850 80

BYO-2520 BYO-3015

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS. ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.




CHILLERS-WATER/AIR COOLING FEATURES

SAFETY AND INDICATION

1. JAPAN MADE“OMRON, YAMATAKE”P.I.D

◆ MAIN POWER, NON-FUSE BREAKER

INTERIOR COUNTED, ACCURACY AND STABILITY.

◆ POWER, PHASE LACK & REVERSE PROTECTION.

2. MAJOR ELECTRIC PARTS FROM JAPAN“FUJI,

◆ COMPRESSOR OVERLOAD PROTECTING AND

OMRON, YAMATAKE”

INDICATING LAMP

3. COMPRESSOR, FROM USA “COPELAND”

◆ PUMP REVERSAL PROTECTING AND

4. SHELL-AND-TUBE TYPE CONDENSER, EVAPORATOR ARE PASSED ISO 9001 CERTIFICATION HIGH

INDICATING LAMP ◆ PUMP OVERLOAD PROTECTING AND

EFFICIENCY, BOTTOM PROBLEM, SAVING 30% MORE OF ELECTRICITY.

INDICATING LAMP ◆ COOLING WATER OVERHEAT PROTECTING

5. SAME/LARGER THAN MODEL BYC-10 ARE ASSEMBLED 2 SETS OR 4 SETS OF COMPRESSORS, UTILIZING

AND INDICATING LAMP ◆ ANTI-FREEZING PROTECTING AND

INDEPENDENT OR TOGETHER.

INDICATING LAMP

6. COMPLETE WITH SAFETY PROTECTION AND BREAK DOWN INDICATION SYSTEMS, USER-FRIENDLY OPERATION. 7. THE COPPER TUBE IS TO USE THE WAY OF OXYGEN

◆ REFRIGERANT SHORTAGE PROTECTING AND INDICATING LAMP ◆ REFRIGERANT HIGH-PRESSURE PROTECTION

FREE WELDING, REDUCING IMPURITY, INCREASING

◆ ICE WATER BY-PASS CIRCULATION

EFFICIEN, EXTENDING THE LIFE OF COMPRESSOR.

◆ ICE WATER OUTLET-PRESSURE GAUGE ◆ REFRIGERANT LOW-PRESSURE GAUGE ◆ BUZZER

SPECIFICATION AIR COOLING MODEL

BYC-02A

BYC-05A

BYC-07A

BYC-10A

BYC-15A

BYC-20A

REFRIGERANT R407 or R22 POWER SUPPLY (V/HZ/3Ø) AC220~440 50/60 TEMP. RANGE (℃) 8 - 30 ACCURACY OF TEMP. CONTROL (℃) ±4 COMPRESSOR (kW) 1.50 3.75 5.50 3.75 × 2 5.5 × 2 7.50 × 2 COOLING CAPACITY (Kcal/hr) 50 HZ 4,838 12,096 18,144 24,192 36,288 48,384 60 HZ 6,048 15,120 22,680 30,240 45,360 60,480 PUMP NOMINAL POWER ((kW) 0.375 0.75 0.75 1.50 1.50 1.50 FLOW RATE MAX. (L/min) 50 HZ 90 130 130 270 270 440 108 170 170 308 308 490 60 HZ 50 HZ PRESSURE MAX. (kg/cm2) 2.0 2.2 2.2 2.3 2.3 2.2 2.2 2.8 2.8 2.3 2.3 2.2 60 HZ MAX. POWER CONSUMPTION (kW) 2.25 4.50 6.25 9.00 12.50 16.50 TANK CAPACITY (L) 40 80 100 120 150 150 ICE WATER MAINS (Inch) 3/4 1-1/4 1-1/4 1-1/2 1-1/2 2 COOLING WATER MAINS (Inch) 3/4 1-1/4 1-1/4 1-1/2 1-1/2 2 DRAINING WATER MAINS (Inch) 1/2 1100×500×1380 1400×740×1280 1700×900×1380 1900×900×1380 2450×1000×1380 2600×1100×1860 DIMENSIONS L× W × H (mm) WEIGHT (kg) 170 350 450 750 950 1,100 DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS. ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES.

10


BYC-05

OPTIONS AVAILABLE ◆ ◆ ◆ ◆ ◆

TIMER FILTER ELECTRIC LEAKAGE CIRCUIT BREAKER COOLING TOWER 3-PHASE VOLTAGE REALY (APR-3)

SPECIFICATION WATER COOLING MODEL REFRIGERANT POWER SUPPLY (V/HZ/3Ø) TEMP. RANGE (℃) ACCURACY OF TEMP. CONTROL (℃) COMPRESSOR (kW) COOLING CAPACITY (Kcal/hr) 50 HZ 60 HZ PUMP NOMINAL POWER (kW) FLOW RATE MAX. (L/min) 50 HZ 60 HZ 50 HZ PRESSURE MAX. (kg/cm2) 60 HZ MAX. POWER CONSUMPTION (kW) TANK CAPACITY (L) ICE WATER MAINS (Inch) COOLING WATER MAINS (Inch) DRAINING WATER MAINS (Inch) DIMENSIONS L× W × H (mm) WEIGHT (kg)

BYC-02W BYC-03W

BYC-05W

BYC-07W

BYC-10W

BYC-15W

BYC-20W BYC-25W

BYC-30W

BYC-40W

BYC-50W

R407 or R22 AC220~440 50/60 8 - 30 ±4 1.50

2.25

3.75×2

5.5×2 7.50×2 9.38×2 11.25×2 7.5×4 18.75×2

4,838

7,257

12,096 18,144

3.75

5.50

24,192

36,288 48,384 60,480 72,576 96,768 120,960

6,048

9,072

15,120 22,680

30,240

45,360 60,480 75,600 90,720 120,960 151,200

0.375

0.75

0.75

0.75

1.50

1.50

1.50

2.25

2.25

3.75

90

100

130

130

270

270

440

580

580

910

910

108

130

170

170

300

300

490

650

650

1,013

1,013

2.0

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.2

2.6

2.6

3.75

2.2

2.8

2.8

2.8

2.8

2.2

2.2

2.2

2.2

2.6

2.6

1.875

3.00

4.50

6.25

9.00

12.50

16.50

21.01

24.75

33.75

41.25

40

40

80

80

120

120

160

200

200

250

250

3/4

3/4

1-1/4

1-1/4

1-1/2

1-1/2

2

2-1/2

2-1/2

3

3

3/4

3/4

1-1/4

1-1/4

1-1/2

1-1/2

2

2-1/2

2-1/2

3

3

1/2 950×480×980

170

220

1200×600×1110 1500×700×1460 1900×900×1500 2200×900×1560 2400×1000×1800

300

350

700

800

1,000

1,150

1,300

1,500

1,700

DESIGN & PRODUCTION ARE AVAILABLE FOR SPECIAL SPECIFICATIONS. ANY NEW MODIFIED SPECIFICATIONS SHOULD BE REFERRED TO EXISTING MACHINES. 11


BYYOUNG INTERNATIONAL CO., LTD. No.13, Lane 642, Chung Jeng Rd, Shu Lin City, Taipei Hsien, Taiwan. Tel : 886-2-8688-1955 (Rep.) Fax : 886-2-8688-2027 E-mail : byyoung@ms69.hinet.net Http://www.byyoung.com.tw

BYOUNG  

TEMPERATURE CONTROL UNITS