Page 1

Communication Solutions for Schneider Electric Users

A S I A

P A C I F I C

|

A F R I C A

|

E U R O P E

|

M I D D L E

E A S T

|

L A T I N

A M E R I C A

|

N O R T H

A M E R I C A


ProSoft Technology®

Tech Support ProSoft Technology is one of the few privately held companies with an exclusive focus on industrial communication. Our flexibility and speed in developing new, quality products as well as our technical support are unparalleled in the industry.

Asia Pacific

Malaysia Office Phone: +603.7724.2080 asiapc@prosoft-technology.com Languages spoken: Chinese, English

Who we are... At ProSoft Technology® our primary focus is to provide connectivity solutions that link dissimilar automation products. In everything we do, the products we develop and the services we offer, we consider quality a priority. Unlike other companies, we don’t just sell products. We sell tested, field-proven solutions. Our goal is to support our customers from pre-sales through the entire life-cycle of the application. We provide total solutions with quality products developed with customers in mind, a well-respected brand and industry-leading technical support. For years, ProSoft Technology products have been used worldwide in nearly every industry. Our product lines have grown to over 400 communication modules supporting more than 60 different industrial communication protocols. ProSoft Technology has regional offices around the globe along with worldwide distribution to meet all your industrial application needs.

China Office Phone: +86.21.5187.7337 asiapc@prosoft-technology.com Languages spoken: Chinese, English

Europe, Middle East, Africa France Office

Phone: +33 (0)5.34.36.87.20 europe@prosoft-technology.com Languages spoken: French, English

Middle East and Africa Phone: +971.(0)4.214.6911 mea@prosoft-technology.com Languages spoken: English, Hindi

North America

Corporate Headquarters Phone: +1 661.716.5100 support@prosoft-technology.com Languages spoken: English, Spanish

Latin America Brazil Office

Phone: +55.11.5083.3776 brasil@prosoft-technology.com Languages spoken: Portuguese, English

Mexico and Central America Office Phone: +52.222.3.99.6565 soporte@prosoft-technology.com Languages spoken: Spanish, English

Regional Office Phone: +1.281.298.9109 latinam@prosoft-technology.com Languages spoken: Spanish, English

We don’t just sell products. We sell tested, field-proven solutions.

To continue our world-class technical support, we have opened offices in most time zones in an effort to support our customers at a local level. See back cover for more contact information.


ProSoft Technology®

PROFIBUS Solutions PROFIBUS DPV1

PROFIBUS DP Slave

Features

Features

• Acts as input/output module between the PROFIBUS network and processor

• Supports PROFIBUS DPV0 Slave implementation • Up to 244 bytes of Input and Output data, for a maximum of 400 bytes total.

• Includes software to intereface between any compliant FDT device DTM and applicable PROFIBUS slave devices.

• Ability to connect to a PC for configuration and troubleshooting

• Hot Standby features support for SE 140 671 CPU • Configuration over Ethernet • Supports up to 125 slave devices with repeaters

Quantum PLC with PTQ-PDPS

PROFIBUS Compatible Processor

HSBY Link

PROFIBUS DP Master

Hot-Standby Quantum controllers with PTQ-PDPMV1

DP Field Devices DP/PA third-party coupler or link module

PROFIBUS Distributed IO PROFIBUS DP

PROFIBUS Drive

DP Field Devices

DP/PA third-party coupler or link module

PA Field Devices

PA Field Devices

Typical Applications for In-Chassis Interface Modules Modbus

Interface with Modbus-compatible devices found in nearly every industry

DF1

Connect legacy Allen-Bradley PLCs

DNP IEC 60870-5 IEC 61850

Connect RTUs, Intelligent Electronic Devices and protection equipment in substation automation applications to controllers

PROFIBUS

Power generation & distribution, oil and gas, water/wastewater and packaging

HART

Devices commonly supporting the protocol include pressure, temperature, flow transmitters, as well as other similar instruments commonly found in the process and other industries.

www.prosoft-technology.com | For a complete list of in-chassis solutions and part numbers, see page 10.

3


ProSoft Technology®

Modbus Communication Module

DF1 Interface Module Features • Configurable as a Master or Slave

Features

• Two serial ports supporting the DF1 protocol

• Emulates Modbus Master or Slave devices

• Asynchronous data transfer to the DF1 network

• Adds two additional Modbus Serial ports to existing platform

Quantum PLC with PTQ-DFCM

• Compatible with all Quantum programming packages

SLC

• Suitable for SCADA and field device interface applications

RTU 5/05 RUN FL FLT BATT

FORCE DH485 Modbus

RUN

PROG

Allen-Bradley

Modbus

DF1

Quantum PLC with PTQ-MCM IN POWER RUN FAULT FORCE OUT

IED Transmitter

MicroLogix

SCADA DCS Station

SCADAPack

IED

HART Multi-drop Modules

330

SCADA RTU

Features

• Supports four Master channels with each channel configured independently to emulate a HART Master

Integrated Flow Computers

• Each Master is completely user-configurable • Supports up to 15 HART devices per channel • Supports the HART Multi-drop implementation of the protocol

Features • Supports data archiving and event logging • Measurement standards supported: AGA 3, 7, 8 and API 2540

Quantum PLC with PTQ-HART

• Module is recognized as an Options modules and has access to PLC memory for data transfer

• Calculates flow rates, accumulated volumes, accumulated mass and accumulated energy • Supports 8-16 meter runs with 4 streams per meter run for the measurement of hydrocarbon gases and liquids using currently accepted industry standards

4

HART Multi-drop

Up to 15 Field Devices per channel

For a complete list of in-chassis solutions and part numbers, see page 10. | www.prosoft-technology.com


ProSoft Technology®

Smart Energy Solutions Modbus TCP/IP to IEC 61850 Gateway

Server Features

Quantum PLC

IEDs n

Modbus TCP/IP

IEC 60870-5-104 Solutions

3

SCADA System

• One TCP server socket • Supports unsolicited messages, either cyclic or spontaneous

IEC 61850

ETHERNET LINK/ ACT

• Functions as a Server on the network supporting data read/write commands from an IEC 60870-5-104 client

Quantum PLC with PTQ-104S

SCADAPack

330

SCADA RTU IED IED Relay

E 1

100 Mbit MS

NS RESET

ERR

CFG

FLT

PWR

1

2

IEC 60870-5-104 Networks

Client Features

PLX81-MNET-61850

Quantum PLC with PTQ-104C

• 104C module supports up to 4 clients

IEDs

Features

• Event timestamping configurable by type

• Configuration Utility integrates tightly with Unity Pro • Polls up to 20 IEC-61850 server devices or 45 clients • Gateway configuration is stored on an industrial SD card for rapid disaster recovery • Modbus TCP/IP Client/server support enables multiple Modbus TCP/IP devices to interface with IEC-61850 devices simultaneously

• Hot Standby mode allows module to be controlled by a secondary Quantum processor in the event of main processor failure • Event timestamping configurable by type

IEDs/RTUs

DNP3 Solutions Serial Features

Ethernet Features

• Supports highly configurable support of both DNP3 Master and slave implementations

• Acts as a Server on a DNP Ethernet network • Allows user to set on-line/off-line quality flag that is reported to the DNP host.

• Recognized as an Options module and has access to PLC memory for data transfer

• Module supports DNP Subset Level 2 features and some Level 3 features allowing SCADA systems supporting DNP protocol to be integrated into the Quantum platform

• Two DNP protocol ports can be configured to operate in a Master/Slave or Slave/Slave redundant port configuration • Master port supports up to 40 slave devices Quantum PLC with PTQ-DNPQ

Quantum PLC with PTQ-DNPSNET-Q

Power Relay Substation Controller

IED Relay

IED Control SCADAPack

330

SCADA System

DNP3

www.prosoft-technology.com | For a complete list of in-chassis solutions and part numbers, see page 10.

DNP3 Ethernet

5


ProSoft Technology®

Building Automation Gateways ProSoft Technology’s Building Automation Gateways connect Schneider Electric PLCs to building automation systems and devices such as HVAC controls, VFD, generators, VAV, boiler controls, chillers, air conditioners, fume hoods, among others. The gateways enable communication between common building automation protocols, like BACnetTM MS/TP, BACnet™/IP LonWorksTM and JCI Metasys® N2 networks, with several of the more pervasive serial and Ethernet protocols, including Modbus and Modbus TCP/IP. These stand-alone alternatives serve applications where an in-chassis solution is not available.

Features • Ability to interface up to 250 or 500 BAS points • BACnet COV support for fast data communication while reducing traffic on the BACnet network • DIP switches to select Baud rate or Node ID • Common interfaces include Modbus Serial, Modbus TCP/IP, BACnet/IP, BACnet, LonWorks and Johnson Controls Metasys N2

6

For a complete list of in-chassis solutions and part numbers, see page 10. | www.prosoft-technology.com


ProSoft Technology®

Industrial Stand-Alone Gateways Modbus Gateways Features • Serial ports on the gateway can be individually configured to support the Modbus protocol (Master or slave, RTU, Baud Rate, etc.) Modbus Master/Slave to EtherNet/IP Gateway

• Provides access to 4,000 registers • Up to 100 commands per Master port

Modbus Master/Slave to IEC 60870-5-101 Slave Gateway

Modbus Master/Slave to HART Multi-drop 4 or 8 Channel Gateways

• Supports floating point data transactions

Premium PLC

Modbus Master/Slave to DNP3 Slave Gateway

Modbus Master/Slave to IEC 60870-5-104 Server 1 or 4 Port Gateways

Modbus

D E B U G ERR

E T H E R N E T

ERR

LINK

ERR

-

+ -

EtherNet/IP

-

-

E T H E R N E T

DATA

CFG

ERR

POWER

FAULT

+

LINK

DATA

ERR

-

CH4

CH2

CH1

CH4

CH3

HART Analog

-

+ -

E T H E R N E T

ERR

CFG

E T H E R N E T

24 VDC +

GND +

ACT

LINK

LINK

+ -

CH1

-

+

24 VDC -

GND + -

CH2

+

CH3

+

CH4

+

GND

-

-

CH1 CH2 CH3 CH4

GND

24 VDC

GND

+ -

+ -

+ -

+ -

CH1 CH2 CH3 CH4

GND

CH2

CH6 CH1

CH5

RESET RESET CH4 CH3CH4

CH8 CH3

CH7

ERR

CH2

HART

HART

+

ACT

+

DATA

CFG

DATA

HART Multi-drop

CFG

FAULT FAULT POWER POWER

POWER

5107-MCM-HART (4 channel)

EtherNet/IP Controller

HART

D E B U G ERR

CH1 CH2 CH3

GND

RESET

D E B U G

24 VDC

GND

+

5201-DFNT-MCM

M340 PAC

+

ACT

+

RESET

FAULT

HART

D E B U G

ACT

5127-MCM-HART (8 channel)

1 Field Device Up to 15 Field Devices on each channel

Modbus

D E B U G ERR

D E B U G

PORT 1 ACT

P O R T

ERR ERR ACT

PORT 2

0 ERR

ACT

INACTIVE PORT

ERR ACT

IEC 60870-5-101

PORT 3

FAULT

CFG

ERR

0 ACT

E T H E R N E T

RESET ERR

D E B U G ACT

P O R T

ERR

LINK

0

ERR FAULT

POWER

5102-MCM3-101S

LINK

IEC 60870-5-104

DATA RESET

ERR

CFG POWER

5102-DNPS-MCM3

ACT

E T H E R N E T

DATA RESET

ERR ACT

ACT

P O R T

DNP3

ERR

FAULT

CFG POWER

5102-104S-MCM

Substation Controller Power Relay

SCADA System

www.prosoft-technology.com | For a complete list of in-chassis solutions and part numbers, see page 10.

7


ProSoft Technology®

Industrial Stand-Alone Gateways Modbus TCP/IP Gateways Features • Supports up to five independent server connections • Supports one client connection on the TCP/IP network, able to connect up to 100 servers/devices with 100 commands

Modbus TCP/IP to DNP3 Slave Gateway

• No configuration of the gateway is required to implement Server functionality other than setting up the network and database parameters in the user configuration file

Modbus TCP/IP to HART Multi-drop Gateways (4 or 8 channels)

Quantum PLC

Modbus TCP/IP to HART Analog Gateways (4 or 8 channels)

Modbus TCP/IP to EtherNet/IP Gateway

Modbus TCP/IP to IEC 60870-5-101 Slave Gateway

Modbus TCP/IP to IEC 60870-5-104 Server Gateway

Modbus TCP/IP

D E B U G

D E B U G ERR

LINK

DNP3

ERR

LINK

FAULT

Premium PLC

+

+ -

-

ERR FAULT

+

LINK

24 VDC

CH1 CH2 CH3 CH4

GND

DATA

RESET

CFG POWER

5201-MNET-DFNT

5201-MNET-DNPS

-

GND

+ E T H E R N E T

RESET ERR

CFG POWER

+

ACT

-

EtherNet/IP

DATA

RESET ERR FAULT

ACT

E T H E R N E T

DATA

HART

D E B U G

ERR

ACT

E T H E R N E T

CH2

CH1

CH4

CH3

HART Analog

CFG POWER

5207-MNET-HART (4 channel)

EtherNet/IP Controller

1 Field Device

SCADA System

Modbus TCP/IP

D E B U G ERR

HART

D E B U G ERR

-

-

ERR

ERR

24 VDC +

GND +

ACT

+

E T H E R N E T

LINK

LINK

+ -

CH1

-

+

24 VDC -

GND + -

CH2

+

CH3

+

CH4

+

GND

CH2

HART

HART

+

ACT

+

E T H E R N E T

-

-

CH1 CH2 CH3 CH4

GND

-

+ -

+ -

+ -

CH2 CH3 CH4

GND

CH6 CH1

CH5

RESET RESET CH4 CH3CH4

CH8 CH3

CH7

CFG

DATA

ERR

CH1

CH2

DATA

D E B U G

24 VDC

GND

+

HART Multi-drop

D E B U G ACT

ERR

P O R T 0 ERR

ACT

E T H E R N E T

LINK

IEC 60870-5-101

DATA RESET

CFG

ERR

FAULT FAULT POWER POWER

FAULT

LINK

IEC 60870-5-104

DATA RESET

CFG

ERR

POWER

FAULT

5201-MNET-101S

5228-MNET-HART (8 channel)

ACT

E T H E R N E T

CFG POWER

5201-MNET-104S

Substation Controller Power Relay

Up to 15 Field Devices on each channel

8

For a complete list of in-chassis solutions and part numbers, see page 10. | www.prosoft-technology.com


ProSoft Technology®

Industrial Stand-Alone Gateways Modbus Plus Gateways Features • True Peer-to-Peer connectivity with the Modbus Plus network • Actively exchanges Global In and Out Data with Modbus Plus network • Supports Master Read/Write commands

Modbus Plus to IEC v-5-101 Slave Gateway

Modbus Plus to IEC 60870-5-104 Slave Gateway

Modbus Plus to Modbus Master/Slave Gateways (1 or 4 Ports)

Modbus Plus

D E B U G ERR

D E B U G

P1

ACT

P O R T 0 ERR

ACT

M O P D L B U U S S

ERR

Modbus

P1 ERR P2 ERR MBP ACT P2

INACTIVE PORT RESET ERR FAULT

M O P D L B U U S S

LINK

DATA

RESET

CFG

ERR

POWER

FAULT

5301-MBP-MCM

D E B U G

P1

ACT

M O P D L B U U S S

P1 ERR P2 ERR MBP ACT E T H E R N E T

P2 M O P D L B U U S S

ERR

P1

ACT

P O R T

IEC 60870-5-104

0 ERR

ACT

M O P D L B U U S S

P1 ERR P2 ERR MBP ACT P2

INACTIVE PORT RESET ERR

CFG

FAULT

POWER

5303-MBP-104S

M O P D L B U U S S

IEC 60870-5-101

CFG POWER

5301-MBP-101S

Quantum PLC

Power Relay

SCADA System

SCADA System

HART Gateways HART Analog Features • Creates a powerful connection between HART analog field instruments and Modbus TCP, EtherNet/IP or DF1 networks • Independent HART Channels

HART

D E B U G

+ -

ERR

+ + -

+ -

+

LINK

E T H E R N E T

24 VDC

GND

ACT

-

Modbus TCP

CH1

HART Analog

CH2 CH3 CH4

GND

DATA

RESET ERR

CH2

CH1

CH4

CH3

POWER

HART

D E B U G

+ -

ERR

Modbus TCP/IP to HART Analog Gateways (4 or 8 channels)

Premium PLC

+

DATA

RESET

• Supports up to 15 devices on each HART channel

HART

D E B U G ERR

Modbus TCP

CH1

HART Analog

CH2 CH3 CH4

CH4

CH3

1 Field Device

POWER

HART + -

-

+ -

+

LINK

-

-

24 VDC

GND -

+

CH2

-

+

CH3

-

+

CH4

CH2

+

+

CH1

-

GND

CH1

HART Multi-drop

CH2 CH3 CH4

GND

CH6

CH5

CH8

CH7

DATA

RESET

FAULT

24 VDC

GND +

ACT

+

E T H E R N E T

ERR

CH4

CH3

CFG POWER

HART

D E B U G ERR

HART + -

24 VDC

GND +

ACT

-

+ -

E T H E R N E T

ERR

-

-

24 VDC

GND -

-

+

CH3

-

+

CH4

CH2

+

+

CH2

-

GND

CH1 CH2 CH3 CH4

GND

CH6

CH5

CH8

CH7

HART Multi-drop

DATA

RESET

FAULT

+

LINK

+

CH1

Modbus TCP 5228-MNET-HART (8 channel) +

Quantum PLC

-

+

CH1

5208-MNET-HART (4 channel)

HART Multi-Drop Features

Quantum PLC

-

+

GND

CH2

CFG

FAULT

Premium PLC

-

+

LINK

E T H E R N E T

24 VDC

GND

ACT

Modbus TCP 5208-MNET-HART (4 channel) ERR

• Available with 4 or 8 channel implementations

1 Field Device

CFG

FAULT

CH4

CH3

CFG

POWER

5228-MNET-HART (8 channel)

Up to 15 Field Devices on each channel Up to 15 Field Devices on each channel

Modbus TCP/IP to HART Multi-drop Gateways (4 or 8 channels) www.prosoft-technology.com | For a complete list of in-chassis solutions and part numbers, see page 10.

9


In-Chassis Product Selection Chart

ProSoft Technology® 3 easy steps to find your in-chassis solution

1) Find your specific network protocol from the “Protocol/Connectivity” column of the chart. 2) In the row for that protocol you’ll find the part number, product features and protocol features for the solution you need. 3) For pricing, distributor location or additional product information, datasheets and user manuals, please visit www.prosoft-technology.com.

Protocol / Connectivity

Part Number

Product Features

Protocol Features

‘C’ Programmable

PTQ-ADM

Allows user-developed ‘C’ applications to operate on the Quantum platform. A great way to speed up custom ASCII data communications or to protect a proprietary algorithm.

Typical applications requiring ‘C’ program development are printer drivers, barcode scanner interface or where Intellectual Property concerns for proprietary customized logic or program code must be utilized in a secure environment.

‘C’ Programmable over Ethernet

PTQ-ADMNET

Allows user-developed ‘C’ applications to operate on the Quantum platform. Supports Ethernet-compatible devices and hosts.

DF1

PTQ-DFCM

Master/Slave Communication Module allows Modicon Quantum processors to easily interface with DF1 protocol compatible devices and hosts.

Devices commonly supporting the DF1 protocol include Rockwell Automation PLCs and power monitoring equipment.

DH-485

PTQ-DH485

Allows Modicon Quantum processors to easily interface with DH-485 protocol compatible devices.

Compatible devices include not only Rockwell Automation PLCs but also a wide assortment of end devices.

DNP3 Slave

PTQ-DNPS

Allows Modicon Quantum processors to easily interface with DNP protocol compatible devices. Allows user to set on-line/off-line, restart, forced, communication lost quality flags.

The DNP protocol was developed for the Power Utility industry and is recommended by the IEEE for RTU-IED communication applications. It can also be found in water/wastewater and oil and gas applications.

DNP3 Quality Flag

PTQ-DNPQ

Allows user to set on-line/off-line quality flag that is reported to the DNP host.

DNP over Ethernet with Quality Flag

PTQ-DNPSNET-Q

Allows user to set on-line/off-line quality flag that is reported to the DNP host.

Flow Computer

PTQ-AFC

The ProTalk Liquid & Gas Flow Computer allows Quantum processors to easily support flow applications performing measurement of hydrocarbon gases or liquids using AGA 3, 7, 8 and API 2540 measurement standards.

Typically used in the oil and gas industry in the transfer of hydrocarbon gas or liquid from a seller to a buyer.

HART Multi-drop

PTQ-HART

Allows Quantum processors to easily interface with HART compatible devices.

HART compatible devices include pressure, temperature, and flow transmitters as well as other similar instrument commonly found in the process industry.

IEC 60870-5-101 Master

PTQ-101M

Allows Quantum I/O compatible processors to interface with IEC 60870-5-101 slave (controlled unit) devices.

Originally developed for the Power Utility industry, compatible devices include relays, breakers, and sub-station communication modules.

IEC 60870-5-101 Slave

PTQ-101S

Allows Quantum processors to interface easily with IEC 60870-5-101 protocol compatible hosts.

IEC 60870-5-103 Master

PTQ-103M

Allows Quantum I/O compatible processors interface with IEC 60870-5-103 compatible devices.

IEC 60870-5-104 Client

PTQ-104C

Allows compatible processors to interface easily with other IEC 60870-5-104 protocol-compatible servers such as RTU’s and IED devices.

IEC 60870-5-104 Server

PTQ-104S

Allows Quantum I/O compatible processors to interface with IEC 60870-5-104 compatible hosts.

Modbus Master/Slave

PTQ-MCM

Adds additional Modbus Master And/Or Slave communication ports to Quantum processors. Supports RS-232, RS-422 or RS-485 network types.

Common protocol used globally in a variety of industries.

PROFIBUS DP-V1 Master

PTQ-PDPMV1

Allows Quantum processors to easily interface with a PROFIBUS DP slave devices.

Industries that use PROFIBUS technology include power and distribution applications, petrochemical, water and gas, SCADA and DCS.

PROFIBUS DP Slave

PTQ-PDPS

Allows Quantum processors to easily interface with a PROFIBUS DP Master device.

Scan here to view our Schneider Electric in-chassis solutions

10

Scan here to view our gateway selection guide


Stand-Alone Gateways Product Selection Chart

ProSoft Technology® 3 easy steps to find your gateway solution

1) Find your specific network protocol from the green row of one of the charts. 2) Follow that column down until it intersects with the required application protocol you wish to connect to. 3) For pricing, distributor location or additional product information, datasheets and user manuals, please visit www.prosoft-technology.com.

Application / Protocol

DNP3 Master

DNP3 Slave

DNP over Ethernet

EtherNet/IP™

BACnet/IP

PS-QS-1010-0780 (250 Point) PS-QS-1510-0780 (500 Point)

BACnet MS/TP

PS-QS-1010-0780 (250 Point PS-QS-1510-0780 (500 Point)

DNP3 Master

5201-DFNT-DNPM

DNP3 Slave

5201-DFNT-DNPM

5201-DFNT-DNPS

5201-DFNT-DNPSNET

5205-DFNT-PDPS 5201-DFNT-103M

IEC 60870-5-104 Server

5201-DFNT-104S 5201-DFNT-104C

IEC 61850

PLX81-EIP-61850

LonWorks

PS-QS-1011-0783 (250 Point) PS-QS-1511-0783 (500 Point)

Metasys N2

PS-QS-1010-0782 (250 Point) PS-QS-1510-0782 (500 Point) 5102-DNPM-MCM3

5102-DNPS-MCM3

5201-DNPSNET-MCM 5202-DNPSNET-MCM4

Modbus Plus

5301-MBP-DNPM

5301-MBP-DNPS

5303-MBP-DNPSNET

Modbus TCP/IP

5201-MNET-DNPM

5201-MNET-DNPS

5201-MNET-DNPSNET

PROFIBUS DP Slave

Application / Protocol

5201-DFNT-101S

5107-MCM-HART 5303-MBP-DFNT

5127-MCM-HART

5102-MCM3-101S

5307-MBP-HART

5301-MBP-101S

5207-MNET-HART

5201-MNET-101S

5205-DFNT-PDPS

IEC 60870-5-103 Master

IEC 60870-5-104 Server

Modbus Master/Slave

Modbus Plus

Modbus TCP/IP

BACnet/IP

PS-QS-1010-0757 (250 Point) PS-QS-1510-0757 (500 Point)

PS-QS-1010-0757 (250 Point) PS-QS-1510-0757 (500 Point)

BACnet MS/TP

PS-QS-1010-0757 (250 Point) PS-QS-1510-0757 (500 Point)

PS-QS-1010-0757 (250 Point) PS-QS-1510-0757 (500 Point)

DNP3 Master

5102-DNPM-MCM3

5301-MBP-DNPM

5201-MNET-DNPM

5102-DNPS-MCM3

5301-MBP-DNPS

5201-MNET-DNPS

5201-DNPSNET-MCM 5202-DNPSNET-MCM4

5303-MBP-DNPSNET

5201-MNET-DNPSNET

DNP3 Slave DNP over Ethernet EtherNet/IP™

IEC 60870-5-101 Slave

5201-DFNT-DNPSNET

IEC 60870-5-103 Master

Modbus Master/Slave

HART Multi-drop (8 channels)

5201-DFNT-DNPS

DNP over Ethernet EtherNet/IP™

HART Multi-drop (4 channels)

5201-DFNT-103M

5201-DFNT-104S

PROFIBUS DP Master

5303-MBP-DFNT

5205-DFNT-PDPS

HART Analog (4 channels)

5208-MNET-HART

HART Analog (8 channels)

5228-MNET-HART

HART Multi-drop (4 channels)

5107-MCM-HART

HART Multi-drop (8 channels)

5127-MCM-HART

5307-MBP-HART

PROFIBUS DP Slave

5207-MNET-HART

5507-PDPS-HART

IEC 60870-5-101 Slave

5102-MCM3-101S

5301-MBP-101S

5201-MNET-101S

5105-101S-PDPS

IEC 60870-5-103 Master

5102-MCM3-103M

5301-MBP-103M

5201-MNET-103M

5105-103M-PDPS

IEC 60870-5-104 Server

5201-104S-MCM 5202-104S-MCM4

5303-MBP-104S

5201-MNET-104S

5205-TS-104S-PDPS

PLX81-MNET-61850 PLX82-MNET-61850

IEC 61850 LonWorks

PS-QS-1011-0154 (250 Point) PS-QS-1511-0154 (500 Point)

PS-QS-1011-0154 (250 Point) PS-QS-1511-0154 (500 Point)

Metasys N2

PS-QS-1010-0117 (250 Point) PS-QS-1510-0117 (500 Point)

PS-QS-1010-0117 (250 Point) PS-QS-1510-0117 (500 Point)

Modbus Master/Slave

5102-MCM-103M

5201-104S-MCM 5202-104S-MCM4

5102-MBS3-MBM 5102-MCM4-DFCM4 5301-MBP-MCM 5302-MBP-MCM4

Modbus Plus

5301-MBP-103M

5303-MBP-104S

Modbus TCP/IP

5201-MNET-103M

5201-MNET-104S

5303-MBP-MNET 5303-MBP-MNET

PROFIBUS DP Master PROFIBUS DP Slave

5301-MBP-MCM 5302-MBP-MCM4

5104-MCM-PDPM

5105-MCM-PDPS

5304-MBP-PDPM

5305-MBP-PDPS 5205-MNET-PDPS

5304-MBP-PDPMV1 5105-MCM-PDPS

5305-MBP-PDPS

5205-MNET-PDPS

11


Sales Offices Around the World Asia Pacific

Europe / Middle East / Africa

Latin America

Malaysia Regional Office

France Regional Office

Regional Office

Phone: +603.7724.2080 Fax: +603.7724.2090 asiapc@prosoft-technology.com Languages spoken: Chinese, Japanese, Korean, English

Phone: +33.(0)5.34.36.87.20 Fax: +33.(0)5.61.78.40.52 europe@prosoft-technology.com Languages spoken: French, English, German

Phone: +1.281.298.9109 Fax: +1.281.298.9336 latinam@prosoft-technology.com Languages spoken: Spanish, English

Middle East & Africa

Brazil

Phone: +971.4.214.6911 mea@prosoft-technology.com Languages spoken: Hindi, English

Phone: +55.11.5084.5178 brasil@prosoft-technology.com Languages spoken: Portuguese, English

North Western Europe (UK, IE, IS, DK, NO, SE)

Mexico & Central America

North Asia (China, Hong Kong) Phone: +86.21.5187.7337 Fax: +86.21.5109.6776 asiapc@prosoft-technology.com Languages spoken: Chinese, English

Southwest Asia (India, Pakistan)

Phone:+44.(0)7415.864.902 nweurope@prosoft-technology.com Language spoken: English

Phone: +91.98.1063.7873 india@prosoft-technology.com Languages spoken: English

Central & Eastern Europe, Russia, CIS, Finland

Northeast Asia (Japan, Korea, Taiwan)

Phone: +48.22.250.2546 centraleurope@prosoft-technology.com Languages spoken: Polish, English

Phone: +603.7724.2080 asiapc@prosoft-technology.com Languages spoken: Japanese, Korean, Chinese, English

Southeast Asia (Singapore, Vietnam, Philippines, Thailand, Indonesia, Malaysia) Phone: +603.7724.2080 asiapc@prosoft-technology.com Languages spoken: English

Pacific Rim Phone: +603.7724.2080 asiapc@prosoft-technology.com Languages spoken: English

Phone : +52.222.264.1814 mexico@prosoft-technology.com Languages spoken: Spanish, English

Andean Countries (Venezuela, Colombia, Peru, & Ecuador) Phone: +58.414.653.99.69 Andean@prosoft-technology.com Languages spoken: Spanish, English

Austria, BeNeLux, France, Germany, Switzerland

Southern Cone (Argentina, Bolivia , Chile, Paraguay & Uruguay)

Phone: +33.(0)5.34.36.87.20 germany@prosoft-technology.com Languages spoken: French, English, German

Phone: +54.911 4565.8119 argentina@prosoft-technology.com Languages spoken: Spanish, English

Mediterranean Countries

North America

Phone: +39.342.8651.595 italy@prosoft-technology.com Languages spoken: Italian, English

Regional Office Phone : +1.661.716.5100 Fax: +1.661.716.5101 support@prosoft-technology.com Languages spoken: English, Spanish

www.prosoft-technology.com

© 2001–2013 by ProSoft Technology, Inc. All rights reserved.

SCHNEIDER_33_2013_EN APR 2013

ProSoft Technology Schneider Catalog  