EN XR 4.0 expert unit –X-ray physics for medical education

Page 2

Product Information

X-ray dosimetry Incidental X-radiation ionises the air molecules in the plate capacitor. The ion dose and the ion dose rate can be calculated based on the ionisation current and on the irradiated air mass.

Radiography The length and position of an invisible metal object can be determined with the aid of two X-ray images that are taken perpendicularly with regard to each other.

Effects of contrast media A blood vessel model that is not visible from the outside is visualised on a fluoroscent screen with the aid of a liquid contrast medium and X-rays.

Absorption of X-rays The absorption of X-rays is determined as a function of the absorber thickness and material.

Computer Tomography An object is rotated vertically and subjected to X-rays. An X-ray sensor records the resulting X-ray images (direct, digital imaging). A software program calculates the sectional images and creates a 3-dimensional reconstruction.

Products XRE 4.0 expert set (basic set) Areas of application: fundamental principles and use of X-rays, absorption, and irradiation experiments Core components: XR 4.0 expert unit (X-ray unit), tungsten tube (W), XR measure 4.0 software, optical bench with slides, TESS expert handbook, fluoroscent screen, USB cable, mains power cable + adapter, and much more.

XRE 4.0 expert set

09110-88

XRI 4.0 X-ray imaging (upgrade set) Areas of application: fundamental principles of X-ray imaging, radiography, radiology, and non-destructive testing (NDT) Core components: camera, irradiation object, model blood vessel, implant model, external optical bench, and much more.

XRI 4.0 X-ray imaging - available as of February 2012

09150-88

XRD 4.0 dosimetry and radiation damage (upgrade set) Areas of application: dosimetry, degradation, damage, and ionisation of air Core components: plate capacitor, 600 V power supply unit, DC measuring amplifier, camera, digital multimeter, and much more.

XRD 4.0 dosimetry and radiation damage - available as of February 2012

09170-88

XRCT 4.0 Computer Tomography (upgrade set) Areas of application: 3-dimensional reconstruction, sectional images in the respective position, direct, and digital imaging Core components: direct, digital X-ray image sensor, vertical rotation unit, software package for computed tomography, and much more.

XRCT 4.0 Computer Tomography - available as of February 2012

09180-88

XRW 4.0 wireless demonstration (upgrade set)

© 2011 - Copyright by PHYWE Systeme GmbH & Co. KG. Subjects to alteration, errors and omissions excepted.

Brief description of the experiments:

XRW 4.0 wireless demonstration

PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen / Germany

09115-88

P. +49 (0) 551 604 - 0 F. +49 (0) 551 604 - 107 info@phywe.com www.phywe.com

00254-02

Areas of application: demonstration experiments (operation without a computer), eye-catching representation of measurement values/parameters Core components: digital large-scale display, Cobra4 Display-Connect, transmitter and receiver, and much more.