FEATURE GENERATORS

Product Description

Running/Rated Power

Additional Starting

In Watts

Power In Watts

Total Power Required From Generator To Start And Run Product In Watts

WORK/DIY USAGE

Rotary Drill - 550W

550

770

1320

Electric motors that use brushes will

Impact Drill - 850W

850

1190

2040

Multi Sander - 160W

160

224

384

must be multiplied by the coefficient. For

Orbital Sander - 200W

200

280

480

example, a 500W power drill will require an

Belt Sander - 710W

710

994

1704

the total required power to operate the

Angle Grinder - 850W

850

1190

2040

drill is 500W + 700W = 1200W.

Angle Griner - 2200W

2200

3080

5280

Mitre Saw - 2000W

2000

2800

4800

Planer - 500W

500

700

1200

Jigsaw - 620W

620

868

1488

have a coefficient of approximately 1.4. This means that the start-up power

additional 700W start up power therefore

OTHER USAGE

HELPFUL FORMULAS

Asynchronous motors (squirrel cage type) will have a co-efficient of approximately two.

General guideline per model:

This means that the start-up power must be multiplied by the co-efficient. For example a

This is a guideline to selecting the appropriate generator for

2200W air compressor will require an additional 4400W start up power therefore the total

your requirements.

required power to operate the air compressor is 2200W + 4400W = 6600W.

Air Compressors

Office

Air Compressor 200LT - 2200W

2200

4400

6600

Air Compressor 24LT - 1100W

1100

2200

3300

Computer Monitor

300-500

0

300 -500

Copy Machine

1500 - 2000 0

1500 - 2000

Laser Printer

800 -1200

800 - 1200

0

Wattage = AMPS x Voltage

Ampere = Wattage Voltage

Ampsperphase = kVA x 1000 658

SERVICE, MAINTENANCE AND RUNNING TIPS • Always read the instruction

manual carefully • Before starting the generator, always

starting the generator, once started, switch the choke to the ‘off’ position • Never connect appliances before

ensure that there is sufficient oil and fuel

starting your generator, always start the

in the machine. Generators generally do

generator first, and then connect one

not come with oil already filled. Only use

appliance at a time

SAE30 graded oil and unleaded petrol (for petrol models) and low sulphur diesel (for diesel models). • Do not use dirty fuel or oil in the

generator • Always place the generator on a flat

surface when pouring in the oil and fuel

• Disconnect appliances before switching

off your generator • Switch off the fuel tap prior to turning

off the generator, to allow the fuel in the carburettor to be used • It is recommended that the first service

should be done after 20 running hours

• If you have an electric start generator,

and thereafter at 50-hour intervals

check that the battery is fully charged

• Always operate your generator in a

before starting • Ensure that the choke is on when MAY 2019 DIY & INDUSTRIAL TRADE NEWS

well-ventilated area, as toxic fumes are emitted from the generator.

For more information on Agrinet's Power Master range contact: Samrand Call: 012-657-2222 Email: enquiries@agrinet.co.za Bellville Call: 021-959-5420 Email: belbestel@agrinet.co.za