Page 1

Pressure Reducing Valve RMG 210

Technical Description

210.00 edition 09/2004

Serving the Gas Industry - WORLDWIDE


Pressure Reducing Valve RMG 210 Application • for industrial and laboratory applications; also suitable for small flowrate regulating lines within large volume gas pressure regulating stations • suitable for natural gas and all non-corrosive gaseous media; special version on demand

Advantages • only small setpoint deviations due to inlet pressure variations • easy operation and maintenance • electric remote control of outlet pressure as a special and optional feature • can be provided with internal or external measuring impulse connection

1. Technical Data

2

max. inlet pressure pe max

100 bar

pressure range Wh (see table page 3) - outlet pressure stage - intermediate pressure stage

0.010 bar to 3.5 bar 0.1 bar to 5.0 bar

valve seat diameter

6 mm

flow rate coefficient KG (for natural gas ρn = 0.83 kg/m3)

18 m3/h

connections

screw connection without brazing with compression fitting acc. to DIN 2353 inlet pressure line for pipe outside dia. 12 mm outlet pressure line for pipe outside dia. 16 mm ext. measuring line for pipe outside dia. 12 mm

function and strength

acc. to EN 334

CE-Registration, DIN-DVGW reg. no.

approved

temperature class 2

-20°C to +60°C

weight

measuring unit MN approx. 9 kg, measuring unit MM approx. 5 kg

materials

body internal parts diaphragms and gaskets

filter

RMG 905 (see leaflet 905.00)

special version

single stage version

aluminium alloy brass, stainless steel NBR


Pressure Reducing Valve RMG 210 intermediate pressure stage measuring unit type

pressure range Wa (bar)

outlet pressure control stage spring wire dia. (mm)

0.1 to 0.5

3.3

0.5 to 5.0

4.7

measuring unit type

pressure range Wa (bar)

spring wire dia. (mm)

N

0.010 to 0.040 0.020 to 0.060 0.040 to 0.120 0.080 to 0.200 0.150 to 0.500

2.5 3.0 3.5 4.0 5.0

M

0.3 to 1.5 1.0 to 2.5 2.0 to 3.5

3.3 4.0 4.5

M

Remark:

Flowrate:

For qn > 9 • pa a separate outlet pressure measuring impulse line has to be connected to the pipe section expansion downstream of the regulator (external measuring impulse connection) A supercritical pressure drop is reached at pa ≤ 0.5 pe flowrate calculation at supercritical pressure drop: pz qn = KG • (m3/h) 2

A subcritical pressure drop is reached at pa pe

> 0.5

flowrate calculation at subcritical pressure drop: qn = KG •

pa (pz - pa)

(m3/h)

Attention! Pressures for the above formulas to be inserted in absolute values (bar absolute). pz = chosen intermediate pressure

3


Pressure Reducing Valve RMG 210 2. Dimensions

B

65

135

A

300

c max

Ø Ø aa

e max

inlet without filter

190

inlet with filter RMG 905 90

100

section A-B outlet

inlet

Dimensions in mm measuring unit

Øa

c max

N

200

95

M

125

70

e max

130

4


Pressure Reducing Valve RMG 210 3. Design and operation

outlet pressure control stage setpoint adjusting screw setpoint spring measuring diaphragm breathing line connection for outlet press. stage

intermediate pressure stage lever system measuring diaphragm setpoint spring setpoint adjuster securing cap breathing line connection of the intermediate pressure stage

This two-stage regulator was designed to keep the outlet pressure of a gaseous medium constant in the main and independent of disturbing influences like inlet pressure or flowrate changes. Due to the intermediate pressure unit integrated into this spring-loaded regulator the negative influence of inlet pressure changes upon the regulating accuracy is reduced to a negligible minimum and practically excluded. The regulator assembly consists of a intermediate pressure unit and an outlet pressure control unit. The pressures to be monitored for operation (intermediate pressure, outlet pressure) can be read from gauges. As the measuring point of the outlet pressure is situated within

connection for outlet pressure gauge connection for outlet main orifice and piston of outlet pressure stage orifice and piston of the intermediate pressure stage connection for inlet line or filter RMG 905

the regulator, it is not necessary to provide for connecting a separate measuring line. We recommend, however, to mount the fine-mesh filter RMG 905 into the inlet line, in order to protect the regulator from contamination. The outlet pressure to be controlled is taken by the diaphragm sensing system and compared to the setpoint value given by the setpoint spring. Any control deviation resulting from this comparison is followed by a corresponding (proportional) change of the valve position thus causing a change of flowrate and restoring the outlet pressure to the setpoint. The regulator gives tight shut-off on zero flow.

5


Pressure Reducing Valve RMG 210 special feature

filter

M

measuring impulse connection

measuring unit M

measuring unit of outlet pressure control stage

intermediate pressure stage

measuring unit of intermed. pressure stage

outlet pressure line

type

inlet pressure line

RMG 210 - 12 / 16 - M / N - 1 - 905 - So

4. Type Description (Example)

outlet pressure control stage measuring unit N spec. outlet pressure range Wa (bar)

N 0.010 to 0.040 0.020 to 0.060 0.040 to 0.120 0.080 to 0.200 0.150 to 0.500 M

measuring unit M spec. outlet pressure range Wa (bar)

0.3 to 1.5 1.0 to 2.5 2.0 to 3.5

measuring impulse connection internal connection external connection

1 2

filter without filter in inlet line with filter RMG 905 in inlet line special feature (to be specified in detail)

0 905 So

7


We supply you with products for gas pressure regulation: RMG REGEL + MESSTECHNIK GMBH Osterholzstrasse 45, D-34123 Kassel, Germany Telephone (++49) 561 5007-0 • Fax (++49) 561 5007-107 gas pressure regulators and safety devices

RMG-GASELAN Regel + Meßtechnik GmbH Julius-Pintsch-Ring 3, D-15517 Fürstenwalde, Germany Telephone (++49) 3361 356-60 • Fax (++49) 3361 356-836 gas pressure regulating equipment, displacement meters, complete stations

Bryan Donkin RMG Gas Controls Ltd. Enterprise Drive, Holmewood, Chesterfield S42 5UZ, England Telephone (++44) 1246 501-501 • Fax (++44) 1246 501-500 gas pressure regulating equipment, below ground gas control modules

Bryan Donkin RMG Co. of Canada Ltd. 50 Clarke Street South, Woodstock, Ontario N4S 7Y5, Canada Telephone (++1) 519 5398531 • Fax (++1) 519 5373339 domestic regulators and safety devices

The other RMG Companies: RMG Messtechnik GmbH Otto-Hahn-Strasse 5, D-35510 Butzbach, Germany Telephone (++49) 6033 897-0 • Fax (++49) 6033 897-130 turbine meters, vortex meters, correctors, flow computers, odorizers

Karl Wieser GmbH Anzinger Strasse 14, D-85560 Ebersberg, Germany Telephone (++49) 8092 2097-0 • Fax (++49) 8092 2097-10

works Beindersheim Heinrich-Lanz-Strasse 9, D-67259 Beindersheim/Pfalz, Germany Telephone (++49) 6233 3762-0 • Fax (++49) 6233 3762-40 data logging, monitor systems, danger alarm systems

WÄGA Wärme-Gastechnik GmbH Osterholzstrasse 45, D-34123 Kassel, Germany Telephone (++49) 561 5007-0 • Fax (++49) 561 5007-207 design and assembly of gas pressure regulating and metering stations

ZUG GAZOMET Sp. z o.o. ul. Sarnowska 2, 63-900 Rawicz, Poland Telephone (++48) 65 546 24 01 • Fax (++48) 65 546 24 08 ball valves, accessories, gas pressure regulating and meterign stations

The RMG Group of Companies on the internet: http://www.rmg.de

Serving the Gas Industry - WORLDWIDE

We reserve the right for technical changes

http://www.rmg.com/uploads/myth_download/210_00_gb_0409  

http://www.rmg.com/uploads/myth_download/210_00_gb_0409.pdf