Page 1

Eduard Lehmann GmbH & Co. KG Poststrasse 109 D-73054 Eislingen Tel.: +49-(0)7161-85 04 60 Fax: +49-(0)7161-85 04 65 E-Mail: info@lehmann-it.de Web: http://www.lehmann-it.de


POWER CONTROLLING DISTRIBUTION SYSTEM

1. PCDS Introduction

2

2. Product Code Instruction

3

2.1. PGDS: Power Generatrix Distribution System

3

2.2. PCSM: Power Controlling System Module

3

2.3. PDUM: Power Distribution Unit Module

4

3. Input Style

4

4. PCSM Introduction

5

4.1. No PCSM

5

4.2. Master Circuit Breaker Module

5

4.3. NPM Module Introduction

6

4.4. CPDU Module Introduction

7

4.5. Digital AC Amperemeter Module Introduction

8

5. PDUM Introduction

8

6. Installation Chart

11

7. Wire Terminal Connection Box Chart

11

8. Main Specifications Introduction

12

PDUM

PCDS

CATALOGUE

PDUM

PCSM PGDS

PCDS - Power Controlling Distribution System

All Clever,s PCDS products are manufactured by environmental protection materials and components, accord with the regulations of European Union RoHS directive, and we had passed test of S G S . All rights reserved. Contents are subject to change without prior notice. The pictures are for indication only, subject to the final product.

1


PCDS 1. PCDS Introduction Power Controlling Distribution System, PCDS for short, was designed and developed by Clever company in 2001. PCDS is formed by Power Generatrix Distribution System (PGDS), Power Controlling System Module (PCSM) and Power Distribution Unit Module (PDUM). PCDS Characteristics 1. PGDS general wiring, the max load can reach 3 32A; 2. PCSM has master air circuit breaker function, can automatically alarm when overload, CPDU (Computer Monitor Power Distribute Unit) and NPM (Network Power Manager) function, etc. 3. PDUM has different standard sockets all over the world; 4. PCDS can change and add the PDUM in uninterrupted operation; 5. PCDS can be matched with different PCSM and PDUM according to customers' different technical requirement; 6. Each PCDS can be configured 6 group PDUM at most according to customers' technical requirement; 7. Power input connecting terminal box is convenient for customers to mount and debug on job site; 8. PCDS is vertically mounted in cabinet and the mounting method is very easy, which can save space to the utmost extent.

2


POWER CONTROLLING DISTRIBUTION SYSTEM 2. Product Code Instruction 2.1. PGDS: Power Generatrix Distribution System Code:

PCDS

PG A 1 2 B 2 A 0 6 W case color (W: white) output quantity (6: 6 groups PDUM) controlling function (0: no PCSM) output current (A: 16A) output voltage (2: 220V) input current (B: 32A) input voltage (2: 220V) input method (1: wire terminal connection box input) output standard (A: standard configuration) module type (PG: power generatrix distribution system )

2.2. PCSM: Power Controlling System Module Code:

PC A 1 2 A 2 A 2 0 B case color (B: black) output (0: multi-type) controlling function (2: circuit breaker & CPDU) output current (A: 32A) output voltage (2: 220V) input current (A: 32A) input voltage (2: 220V) input method (1: single input) output standard (A: standard configuration) module type (PC: power controlling system module)

3


PCDS 2.3. PDUM: Power Distribution Unit Module Code:

PD A 1 2 A 2 A 2 5 B case color (B: black) output quantity (5: 5 output units) controlling function (2: fuse & indicator) output current (A: 16A) output voltage (2: 220V) input current (A: 16A) input voltage (2: 220V) input method (1: single input) output standard (A: IEC320 C13) module type (PD: power controlling system module)

3. Input Style

Single input

4

Double input

Wire terminal connection box input


POWER CONTROLLING DISTRIBUTION SYSTEM 4. PCSM Introduction

PCDS

4.1. No PCSM

No PCSM

No PCSM

4.2. Master Circuit Breaker Module

No PCSM Master Circuit Breaker Module

5


PCDS 4.3. NPM Module Introduction Network Power Manager (NPM) which is developed and produced by Clever, is the world-advance new generation network managing power distribution and monitoring device. The governor can monitor, control and manage many pieces of equipments through LAN or WAN in the cabinet of data room located all over the world.

NPM Controlling Module

Monitoring Function The total load current; The operating state of NPM system; The state of temperature/humidity; The state of smog or water logging; The state of cabinet door.

Alarming Function 1. User-defined alarm The Min/Max limiting value of total load current; The Min/Max limiting value of temperature /humidity. 2. System default alarm The total load current exceeds rating value; System goes wrong; Smog; Water-logging; Door opening. 3. Alarming method The indicator of NPM controlling panel flashes and the buzzer alarms. The indicator on the Web interface flashes and the buzzer alarms. Automatically send E-mail to system administrator. SNMP sends alarm information.

6

Daisy-chain Function Support NPM daisy-chain and daisy-chain 10pcs NPM at most by radial link method.

Log Record Record and save the operation information of NPM, provide the query and output of records.

User Management Setting the user rights.

Accessing method Web, access through IE; SNMP (V1/V2C/V3), access to control through standard network working station; Telnet, SSH, access to control through command controlling station.

System Support Multi-user operation system, support software upgrade.


POWER CONTROLLING DISTRIBUTION SYSTEM 4.4. CPDU Module Introduction

PCDS

Computer Monitored Power Distribution Unit - CPDU CPDU module is a kind of PCSM (Power Controlling System Module) which can timely monitor the total load current of the PCDS through PC's hyper terminal when the PC (or other equipments with serial port) is connected with RJ45 port based on the telecom technology of the computer's serial port.

Circuit Breaker+CPDU Controlling Module

Contents Be Monitored And Displayed Main Functions 1. Through PC, timely monitors the total load current of PCDS by visiting the hyper terminal. 2. Timely displays the total load current of PCDS through The digital alternating current ammeter. 3. Timely monitor the load current of 32 pcs CPDU at most. 4. Rating voltage: 125/250VAC 50/60HZ; Rating load current: 16A, 32A.

Monitoring Methods 1. The governor can monitor the total load current of the PCDS through the digital alternating current ammeter on CPDU panel. 2. The governor can monitor the load current of PCDS on the PC's interface through the hyper terminal.

1. Address code (can be set by the governor) 2. Load current value (display the timely load current) 3. State of the load current (Normal or Abnormal) 4. Date (can be modified) 5. Time (can be modified) 6. The overload alarm value (can be modified)

Connection 1. CPDU can be connected to PC with RS-232 or RS485 serial port. 2. When the load current of several CPDU is to be monitored through a PC at the same time, a hub can be applied. 3. Please refer to the above connecting method when CPDU is connected with other equipments with serial port.

7


PCDS 4.5. Digital AC Amperemeter Module Introduction

MB3306A

MB3307A

Max. Input

AC 16A/32A

AC 3 16/32A

Full measurement

AC 16A/32A

Performance index

Accuracy Resolution

AC 16A/32A 1.0%+1Digit

100mA (<10A)

Frequency range

50/60Hz

Digit display

2

Display Overload alarm Power supply

Red LED alarm, LED flashes

alarm, LED flashes L1, L2 and L3 light

125/250VAC

3-Phase Electricity

Circuit Breaker+Digital AC Amperemeter Controlling Module

5. PDUM Introduction

PDA12A2A25B

8

PDC12A2A24B

PDB12A2A23W


PCDS

POWER CONTROLLING DISTRIBUTION SYSTEM

PDF11A1A15W

PDG11A1A25W

PDL12A2A24B

PDM12A2A24B

PDH12A2A24B

PDI12A2A24B

9


PCDS

10

PDJ12A2A24B

PDE12A2A24B

PDD12A2A14B

PDN12A2A23B

PDK12A2A23B

PDB12A2A23W


POWER CONTROLLING DISTRIBUTION SYSTEM

PCDS

6. Installation Chart

1

2

3

4

7. Wire Terminal Connection Box Chart

11


PCDS 8. Main Specifications Introduction

12


PCDS

POWER CONTROLLING DISTRIBUTION SYSTEM

13


http://www.pressebox.de/attachments/263045/2010 PCDS Lehmann_sz  