MIS Warranty: MIS exercises great care and effort in maintaining a superior quality of products. All MIS' products are guaranteed to be clear from defects in material and workmanship. However, should a customer find fault with any MIS product while using it according to the instructions, the defective product will be replaced. Warning: MIS' products should be used by licensed dentists only.


Table of contents. Introduction Advantages Implant range Narrow Platform Ø3.30mm Implants Implant range Standard Platform Ø3.75mm Implants Ø4.20mm Implants Implant range Wide Platform Ø5mm Implants Ø6mm Implants Drilling Procedures Surgical Kit Success Delivery keys Insertion Options. Packaging


4.

Always dedicated to the development of innovative products and technologies, MIS' scientists and engineers conduct continuous laboratory and field studies in collaboration with prestigious universities and dental research institutes. SEVEN is the innovative result of an extensive research and development process, offering a unique combination of surgical and restorative benefits.

Š MIS Corporation. All rights reserved.


4.


6.

Advantages.

Screw type implant standard platform Ă˜ 4.20mm.


Internal hex. MIS SEVEN implants feature an internal hex. connection, assuring proper implant abutment seating, anti-rotational engagement, resistance to lateral forces, excellent esthetic results and more.

Micro rings Micro rings on the implant’s neck improve BIC (Bone To Implant Contact) at the crestal zone.

Dual thread A dual thread design increases BIC (Bone to Implant Contact), reinforcing osseointegration for long lasting clinical success. The overall insertion rate of SEVEN is 2.4mm per revolution.

Conical shape Conical, root-shaped geometry and a unique thread design ensure superior primary stability offering the ultimate choice for a wide range of clinical cases and loading protocols.

Surface The surface roughness and micro-morphology is a result of sand blasting and acid etching. MIS' established surface technology has provided millions of patients and clinicians with excellent osseointegration results and long lasting clinical success.

Three spiral channels Three spiral channels at the apical end of the implant support its self tapping properties. The channels also collect and amass bone chips in the course of insertion, supporting efficient osseointegration and long-term stability.

Domed apex The dome shaped apex prevents over-insertion for safer implant placement procedures.


8.

NARROW ®

Screw type implants range

Narrow Platform Length

6mm

8mm

10mm

11.50mm

13mm

16mm

MF7-13330

MF7-16330

Type MF7-10330

MF7-11330

Ø3.30 mm

Surgical tools

MT-HLI10

Long insertion tool, int. hex. connection

MT-HSI10

Short insertion tool, int. hex. connection

MT-SRA10

Square connection to ratchet adapter

MT-SHA10

Hand wrench square connection

MT-NRH20

Hex. ratchet long adapter for int. hex. connection, NP

Implant cover screws and healing caps Available for heights: 2,3,4mm

MC1-00330

Ø 4mm 2/3/4mm

MH-N2330 MH-N3330 MH-N4330


®

Catalog No.No .Catalog

Dimensions Dimensions

MF7-10330

Ø3.30mm length 10mm

NARROW

Ø3.30mm Narrow Platform

Titanium Alloy Ti 6Al 4V ELI Sand Blasted and Acid-Etched

MF7-11330

Ø3.30mm length 11.50mm

MF7-13330

Ø3.30mm length 13mm

MF7-16330

Ø3.30mm length 16mm 2.10

Ø 3.30

Ø 3.20

L

Final Drill Ø 2.20

Ø 2.40

Each implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.

Ø3.30mm Implant Procedure

Drilling Speed (RPM)

12001500

9001200

Diameter

Ø1.90

Ø2.40

Ø2.40

200400

15-25

Ø2.20 Ø3.20

Ø3.30

Final drill For bone type 1&2

Do not use the final drill for bone type 3&4 The drilling sequence is demonstrated by a 13mm implant. Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.


10.

STANDARD ®

Screw type implants range

Standard Platform 6mm

Length

8mm

10mm

MF7-08375

MF7-10375

11.50mm

13mm

16mm

MF7-13375

MF7-16375

Surgical tools

Type MF7-11375

MT-HLI10

Ø 3.75 mm

Long insertion tool, int. hex. Connection

MT-HSI10

MF7-06420

MF7-08420

MF7-10420

Ø 4.20 mm

MF7-11420

MF7-13420

MF7-16420

Short insertion tool, int. hex. Connection

MT-SRA10 Square connection to ratchet adapter

MT-SHA10 Hand wrench square connection

Implant cover screws and healing caps Available for heights: 3,4,5,6mm

MC1-00375

Ø 4mm 3/4/5/6mm

Ø 5.5mm 3/4/5/6mm

MH-03375 MH-04375 MH-05375 MH-06375

MH-53375 MH-54375 MH-55375 MH-56375


®

Catalog No.No .Catalog

Dimensions Dimensions

MF7-08375

Ø3.75mm length 8mm

STANDARD

Ø3.75mm

Standard Platform

Titanium Alloy Ti 6Al 4V ELI Sand Blasted and Acid-Etched

MF7-10375

Ø3.75mm length 10mm

MF7-11375

Ø3.75mm length 11.50mm

MF7-13375

Ø3.75mm length 13mm

2.45

Ø3.75mm length 16mm

MF7-16375

Ø 3.60

Ø 3.75

L

Final Drill Ø 2.80

Each implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.

Ø 3.10

Ø3.75mm Implant Procedure

Drilling Speed (RPM)

12001500

9001200

Diameter

Ø1.90

Ø2.40

500700 Ø2.40

Ø2.80

Ø2.80

200400

200500

Ø2.8 Ø3.60

Ø3.75

15-25 Ø3.75

OR

Final drill For bone type 1&2

(MT-GDN33) Countersink For bone type 3&4

Do not use the final drill for bone type 3&4 The drilling sequence is demonstrated by a 13mm implant. Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.


12. ®

STANDARD

Ø4.20mm Standard Platform

Catalog No.

Dimensions

MF7-06420

Ø4.20mm length 6mm

Titanium Alloy Ti 6Al 4V ELI Sand Blasted and Acid-Etched

MF7-08420

Ø4.20mm length 8mm

MF7-10420

Ø4.20mm length 10mm

MF7-11420

Ø4.20mm length 11.50mm

2.45

Ø4.20

Ø4.10

MF7-13420

Ø4.20mm length 13mm

MF7-16420

Ø4.20mm length 16mm

Ø 3.75 0.4mm

L

Final Drill Ø3.30

Each implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.

Ø 3.70

Ø4.20mm Implant Procedure

Drilling Speed (RPM)

12001500

9001200

Diameter

Ø1.90

Ø2.40

Ø2.40

500700

400700

Ø2.80

Ø3.20

Ø3.20

200400

200500

Ø3.30 Ø4.10

Ø3.30 Ø4.20

15-25 Ø4.20

OR

Final drill For bone type 1&2

(MT-GDN33) Countersink For bone type 3& 4

Do not use the final drill for bone type 3&4 The drilling sequence is demonstrated by a 13mm implant. Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.


WIDE ®

Screw type implants range

Wide Platform Length

6mm

8mm

10mm

MF7-08500

MF7-10500

11.50mm

13mm

16mm

MF7-13500

MF7-16500

Surgical tools

Type MF7-06500

MF7-11500

MT-HLI10

Ø5 mm

Long insertion tool, int. hex. Connection

MT-HSI10

MF7-06600

MF7-08600

MF7-10600

Ø6 mm

MF7-11600

MF7-13600

Short insertion tool, int. hex. Connection

MT-SRA10

Square connection to ratchet adapter

MT-SHA10

Hand wrench square connection

Implant cover screws and healing caps Available for heights: 3,4,5mm

MC1-00470

Ø 5mm

MH-W3500 MH-W4500 MH-W5500

3/4/5mm

Ø 6.5mm 3/4/5mm

MH-W3630 MH-W4630 MH-W5630


14. ®

Catalog No.

Dimensions

MF7-06500

Ø5mm length 6mm

WIDE

Ø5mm

Wide Platform

Titanium Alloy Ti 6Al 4V ELI Sand Blasted and Acid-Etched

MF7-08500

Ø5mm length 8mm

MF7-10500

Ø5mm length 10mm

MF7-11500

Ø5mm length 11.50mm 2.45

Ø 4.90

Ø5 Ø 4.50

Ø5mm length 13mm

MF7-13500

0.4mm

L

Ø5mm length 16mm

MF7-16500

Final Drill Each implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.

Ø 4.50

Ø 4.10

Ø5mm Implant Procedure

Drilling Speed (RPM)

12001500

9001200

Diameter

Ø1.90

Ø2.40

Ø2.40

500700

400700

400600

Ø2.80

Ø3.20

Ø4

Ø4

200400

200500

Ø4.10 Ø 4.90

Ø5

15-25 Ø5

OR

Final drill For bone type 1&2

Countersink MT-GDN50 For bone type 3&4

Do not use the final drill for bone type 3&4 The drilling sequence is demonstrated by a 13mm implant. Procedure recommended by MIS cannot replace the judgment and professional experience of the surgeon.


®

WIDE

Ø6mm Catalog No.

Dimensions

MF7-06600

Ø6mm length 6mm

Wide Platform

Titanium Alloy Ti 6Al 4V ELI Sand Blasted and Acid-Etched

MF7-08600

Ø6mm length 8mm

MF7-10600

Ø6mm length 10mm

MF7-11600

Ø6mm length 11.50mm 2.45

Ø6 Ø 5.90 Ø 4.50

Ø6mm length 13mm

MF7-13600

0.4mm

L

Final Drill Ø 5.10

Each implant is supplied with a single use final drill corresponding to its diameter and length, allowing a short and safe drilling procedure.

Ø 5.50

Ø6mm Implant Procedure

Drilling Speed (RPM)

12001500

9001200

Diameter

Ø1.90

Ø2.40

Ø2.40

500700

400700

400600

300500

300500

Ø2.80

Ø3.20

Ø4

Ø4.50

Ø5

Ø5

200400

200500

Ø5.10 Ø 5.90

Ø6 OR

Final drill For bone type 1&2

Countersink MT-GDN50 For bone type 3&4

15-25 Ø6


16.

Drilling Procedures.

0 Ø3.3

SP

LL Ø3 .20 TR Ø 2.8 Y IN 0 DR Ø2 ILL .40 KI Ø2 NG DR .40 ILL Ø1 .90

DR

ILL

IN

K IN RS T E NT DY D COU BO IST TW T IS TW RI

UN CO

FIN AL Ø3 DR I L .20 L

NT Implant IM PLA DRILL FINAL

RY

TRY IN Ø5 BODY

TWIST DRILL Ø4.50 TWIST DRILL Ø5

TWIST DRILL Ø4

TWIST DRILL Ø3.20

TWIST DRILL Ø2.80

BODY TRY IN Ø2.40

COU NTER SINK

DY

T LO R PI A M E D A SP

ILL DR AL FIN

BO

Ø 4 .20

TE RS IN K BO F I NA L DRILL DY TRY IN Ø4 TW IST DR I TW LL Ø4 IST DR TW ILL Ø 3.20 IST DR BO ILL Ø DY 2.80 TRY PI L I N Ø2.40 OT SP DR AD ILL Ø EM 2.40 AR KIN G DR ILL Ø1 .90

Ø5

ARKING DRILL Ø SPADE M 1.90 PILOT DRILL Ø2.40

NK SI

Ø6

0 Ø1.9 ILL DR ING 2.40 RK Ø LL .40 MA 2 RI E NØ TD AD YI .80 LO TR Ø2 PI ILL DY 2.80 DR BO NØ L DRILL IST YI FINA TW TR

B

R

Y OD

CO UN TE

.75 Ø3

G DRILL Ø1.90 ARKIN M E D L Ø2.40 SPA T DRIL PILO IN Ø2.40 Y TRY BOD L DRILL FINA


Ø2.80

Ø2.80

Ø3.20

Ø3.20

E

OW RR Ø2.40

D WI

RD DA AN ST

NA Ø2.40

Ø4

Ø4

Ø4.50

Ø5

Ø5

Fin al dr ill

Co un ter sin Bo k dy t ry Tw in ist Ø5 d Tw rill m ist m Ø dr 5m Bo ill m dy Ø4 try Tw .50 ist in m Ø d m Bo rill 4m dy Ø4 m try m Tw m i n ist Ø3 dr Bo .20 ill dy m Ø3 m try .20 Tw in m ist Ø2 m dr .80 ill Bo m Ø2 dy m .80 try m Pil i n m ot Ø2 dr .40 Sp ill Ø m ad 2.4 m e/ 0m m m ar kin g dr ill Ø 1.9 0m m


18.

MT-BTT24

MT-TDT28

MT-BTT28

Advanced Surgical Instrument Kit. MK-EI48

With external irrigation drills

MT-TDN19

MT-SMD10

MT-P2416

MT-P2413

MT-P2411

MT-P2410

MT-P2408

MT-P2406

MT-NRH20

MT-PP240

MT-RI030


MT-TDT32

MT-BTT32

MT-TDN40

MT-BTT40

MT-TDT45

MT-BTT45

MT-TDN50

MT-BTT50

MT-GDN33

MT-GDN50

MT-SHA10

MT-DE001

MT-HLI10

MT-HSI10

MT-LM005

MT-SM005

MT-SRA10

MT-HMR10

MT-DI001


20.

Success. SEVEN implants' high success rate is guaranteed by a combination of advanced geometric design and a cutting-edge surface technology.

Micro Structure - Surface Morphology The surface roughness and microgeometry is achieved by blasting particles and acid-etching. As a result, a larger surface area increases bone-to-implant contact, for long lasting osseointegration.The micro mechanical fixation increases implant stability.


Adsorption of Serum Protein to Modified Titanium Surfaces M.N. Sela, L.Badihi, G.Rosen, D.Kohavi and D. Steinberg

The use of Titanium (Ti) implants is a novel clinical procedure in dentistry. The adsorption of biological molecules to the implant’s surface triggers a sequence of events that may determine the outcome of this procedure. Clinical data suggests that modified Ti surfaces play an important role in the success or failure of the implant. Objective: the purpose of this study was to investigate the interaction between Ti implants with different surface properties and serum proteins, in order to find the optimal implant surfaces which may improve the Osseointegration process and implant intake. Materials & Methods: Six mm in diameter Ti disks with two types of surface modifications were compared: Machined and Sandblast plus Acid-Etched. The disks were coated with mixtures of Human Serum Albumin conjugated with fluorescein (HAS-FITC). Following incubation, the coat was removed from the disks by SDS. A Confocal Scanning Laser Microscope was used to visualize and measure the HAS-FITC coat and the degree of protein removal from the Ti surfaces.

Albumin IGG Fibronectin Fibrinogen

Mi

Conclusions: Absorption of albumin to the rough treated Ti surface is both qualitatively and quantitatively far more intense, as compared with the machined surfaces. Further studies of the chemical and physical characterization of the modified Ti surfaces are underway. Moreover, additional serum proteins, as well as oral microorganisms, are being examined for their interactions with the modified Ti surfaces.

20

cro

Results: The Confocal Microscope images revealed a significantly higher amount of HAS-FITC coat on the rough disks, as compared with the machined disks. Furthermore, under similar experimental conditions, less HAS-FITC could be removed from the rough disks than from the machined disks.

gra

m 15

10

Hebrew University Jerusalem, Israel, IADR August 03, 2004

5

0

Ma ch ine

Im

pla

nt

MI SS urf ac e


22.20.

Short insertion tool, int. hex. Connection

Available within MIS' advanced surgical kit, the SEVEN key system is designed to facilitate quick and reliable implants procedures.

Hand wrench square connection

Square connection to ratchet adapter

The new keys are suitable for use with SEVEN NARROW connectors.

Long insertion tool, int. hex. Connection

Delivery keys.

MT-SRA10 MT-HLI10

MT-SHA10

MT-HSI10


20.

2 1

3

Insertion Options. The unique "3 in One" key system minimizes the number of tools, and maximizes flexibility.

Please note: In order to assure their efficient operation, keys should be fully inserted into the implants. A complete insertion of the key optimizes the transfer of force during implant placement and enables simple .release of the key from the hex. whenever necessary Please note: Key will not hold implant unless it is complety forced into the hex.

1. Insertion tool in hand key adapter 2. Insertion tool for motor 3. Insertion tool in ratchet adapter

The improved insertion tool allows the delivery of a cover screw or a healing cap onto the implant after its insertion.


24.

Package Content.

Each SEVEN implant comes with a large range of sterilized components for any clinical scenario.

Outside Tube

Inside Tube

Final Drill

Implant

Cover Screw

Following the “Make It Simple� philosophy, MIS is proud to be the first to include a sterile single use final drill with every SEVEN implant, to ensure safe and precise surgical procedure.


Advantages.

Prosthetic platform indication Prosthetic components are marked by specific colors, representing their platforms.

Packaging. A double packing system ensures sterilization and safety. Packages are designed for ease of use during surgery and for use with surgical gloves.

Implant diameter & platform indication The outer tube is color-coded, indicating the implant's platform. The numeric indication specifies implant's diameter and length.

Implant identification A sticker on top of the box, specifies implant's diameter, length and platform size.

Easy pull tab The easily identified pull tab facilitates quick and easy opening during surgery.


All rights reserved. No part of this publication may be reproduced, transcribed, stored in an electronic retrieval system, translated into any language or computer language, or be transmitted in any form whatsoever, without the prior written consent of the publisher.


MC-UNO08 Rev.1 MC-SEVEN Rev.11

MIS’ Quality System complies with ®

international quality standards: ISO 13485:2003 - Quality Management System for Medical Devices, ISO 9001: 2008 - Quality Management System and CE Directive for

MIS Implants Technologies Ltd. www.mis-implants.com MIS Implants Technologies Ltd www.mis-implants.com

Medical Devices 93/42/EEC. MIS’ products

0483

ISO 9001:2000 ISO 13485:2003

are cleared for marketing in the USA and CE approved.

Authorized European Representative: MIS Germany, Paulinenstraße 12a, 32427 Minden, GERMANY

© MIS Corporation. All rights reserved. © MIS Corporation. All Rights Reserved.

Seven Catalog  

Seven Catalog

Read more
Read more
Similar to
Popular now
Just for you