Page 1

Spot Check

HBP-T105S


Spot Check HBP-T105S

Simplicity and Comfort! Innovative and original, the new spot check HBP-T105S has been designed to provide Ease of use for you and Comfort for the patient, along with quality and measurement reliability. Fitting closely to your needs Available with NIBP, SPO2 and temperature, specifically designed for bed to bed checks

Easy to use One button operation to take blood pressure

Faster Measurement New COLIN blood pressure module equipped with High-Speed function

Highly Ergonomic Innovative 40 degrees angled display for easy viewing, without any effort

Backlit function buttons Suitable for reduced light conditions, such as a night time ward

With the new T105S Spot Check device, make your daily work easy and gain on comfort!

Nurses check the patient vital signs twice or three times per day and record results. The number of patients per nurse is increasing, meaning that the improvement of operation efficiency is required. That is why comfort and simplicity are really the guideline concepts of this new device.


The “high-speed” blood pressure function of the spot check HBP-T105S saves time for staff, reduces stress and improves patient’s comfort.

Colour leds and backlight reinforce the screen high visibility even in reduced light conditions

One main button to activate NIBP measurement

Ergonomic trolley A brand new ergonomic trolley made of composite material. This new device offers lightness and is very easy to handle while guaranteeing high shock-resistance. Optional storage accessories are available.

Ergonomic display Ergonomic position of the display reinforces the screen high visibility to read the measurements.


Technical Specifications Spot check HBP-T105S

Non-invasive Blood Pressure (NIBP)

Model MDD Classification Alarm Interval Display type Dimension Weight

Degree of protection (enclosures) Type of protection Protection class Safety Standards

HBP-T105S Class IIa No(*) No(*) LED display Main unit: 239 (W) x 239(D) x 150(H) [mm] AC adaptor : 150 (W) x 47(D) x 75(H) [mm] Main Unit (w/o Recorder) : 1.9 [kg] AC adaptor:0.5 [kg] Internal battery:1.5[kg] IP21 Type BF – Applied part Class I IEC60601-1: 1998 + A1: 1991 + A2: 1995

Measurement Technology Measurement method Measurement Time Memory Pressure display range Pressure display accuracy NIBP Measurement range Adult/pediatric mode SYS MAP DIA Pulse rate Neonatal mode SYS MAP DIA Pulse rate NIBP accuracy Pulse rate accuracy Standards

(*) No physiological alarm. All configurations are equipped with technical alarm, alerting of measurement or operational error.

Recorder (Optional) Weight Print type Paper width

200g Thermal 58 mm

Power requirement AC power supply Battery Power supply Standard type Operating time

Charging time Battery saving mode function

100-240V ~ 50/60Hz 12V Lead acid battery 6 hours, when fully charged, no printing, NIBP measurement every 15minutes, in-power saving mode, at 25°C 6 hours, from fully empty to fully charged Yes

60 to 250mmHg 45 to 235mmHg 40 to 200mmHg 40 to 200bpm 40 to 120mmHg 30 to 100mmHg 20 to 90mmHg 40 to 240bpm ANSI / AAMI SP-10 ± 2% or ± 2 beats IEC60601-2-30:1999, EN 1060-1:1995+A1:2002 EN 1060-3 :1997

SpO2 option - Nellcor (Pulse oximeter) Measurement method Measurement range Measurement accuracy

2 wavelength pulse wave type (OxiMax® technology) 70 to 100% SpO2 ± 2 % SpO2 (70 - 100 %SpO2 when using SpO2 disposable MAX-A)

± 3 % SpO2 (70 - 100 %SpO2 when using SpO2 disposable sensor DS-100A)

Pulse Rate Measurement range 20 to 250bpm Pulse Rate Measurement accuracy ± 3bpm Display update Less than 10 sec. Standards ISO9919:2005

Environmental conditions Operating Temperature Storage Temperature Operating Humidity

Oscillometric method Linear deflation Normal / High speed selectabl 400 measurements 0 to 299 mmHg ± 3mmHg

0 - 40°C -20 to 60°C 30 to 85% (not condensed)

SpO2 option - Masimo (Pulse oximeter) 2 wavelength pulse wave type (Masimo SET® technology) Measurement range 70 to 100% SpO2 Measurement accuracy ± 2 %SpO2 (75 -100 %SpO2.DCI) ± 3 % SpO2 (50- 74 %SpO2.Neo) Pulse Rate Measurement range 25 to 240bpm Pulse Rate Measurement accuracy ± 3 bpm Display update Less than 10 sec. Standards ISO9919:2005

1 pc 1 pc 1 pc 1 pc 1 pc 1 pc (w/ Nellcor SpO2 option only) 1 pc (w/ Nellcor SpO2 option only) 1 pc (w/ Masimo SpO2 option only) 1 pc (w/ Masimo SpO2 option only) 1pc (w Alaris Temp option only) 1pc (w/ Alaris Temp option only) 1 pc 2 rolls (w/Printer option only)

Temperature (BT) Option – Alaris

Optional accessories Roll stand Cuffs

Roll stand specifically designed for general wards! Latex free full range of reusable adult cuffs (small, regular, large, extra large) and disposable cuffs for newborn / infant

Measurement method Measurement site Probe Type Measurement range Measurement accuracy Standard

Complete accessory list available from your supplier.

Turbo Temp™ Electronic Predictive Thermometer Sub lingua, Axilla IVAC® 2887 A (Produced by Alaris) 35.6 °C – 41.1°C (Calculated method) 26.7 °C - 41.1°C (Actual method) ± 0.1°C (Actual method) EN12470-4:2000

HBP- T105S

Model

Function

Spot only

Official model name per configuration

NIBP

SpO2

HBP-T 105 S N

HBP-T 105 S NX ne / ma

HBP-T 105 S NXT ne / ma

HBP-T105 S NP

HBP-T 105 S NXP ne / ma

HBP-T 105 S NXTP ne / ma

Temp

Printer

Alarm

Interval

123/1007

Configurations

BC Consultants 01 34 22 05 05

AC adaptor AC adaptor cable Internal battery CUFF HOSE (Adult, 3.5m) CUFF (Adult, regular size) SpO2 cable (DOC-10) SpO2 sensor (DS-100A) SpO2 cable (LNC-10) SpO2 sensor (LNCS DCI) Temperature probe (IVAC 2887) Probe cover (IVAC P850A) Operation manual Printer paper (No.17)

Photos non contractuelles

Measurement method

Standard Accessories

0197

● ● ● ●

ne = Nellcor technology ma = Masimo technology

Distributed by MSH nv/sa Torenstraat 20, B-3384 Glabbeek Tel.: +32(0)16 77 89 31 www.msh.be - info@msh.be

www.omron-healthcare.com

PM-HBP-T105S-01-10/07

http://www.msh.be/var/media/d4cdb1aea376ac019f1d3a47ab08bf11  

http://www.msh.be/var/media/d4cdb1aea376ac019f1d3a47ab08bf11.pdf