Excel Power Distribution Section 9

In this Section: Power Distribution Units Efficiency Measurements Excel Modular PDU Range Excel Standard PDUs Excel Intelligent PDU Family Excel Desktop Power Distribution Units

Pages 160 160 161 162 164 171

S9

159


Excel Power Distribution

Power Distribution Units Power Distribution Units (PDUs) are an important and often overlooked part of an infrastructure design and installation. At their simplest they deliver the power required for the equipment within the rack, more advanced units can provide management information on power consumption and local environmental conditions such as temperature and humidity. It is important to consider the PDU requirement at the rack installation stage rather than as an afterthought at the equipment installation stage. Making sufficient provision for the power will ensure the longevity and best use of the rack. PDUs can be fitted in various different ways within the rack: front; rear; horizontal rack mount; vertical side mount. This may be dependent on – l Available space in the rack l Position of equipment l Position of the power input for specific equipment

What capacity and how many PDUs should there be? For a rack that will be dedicated for equipment consideration should be made for dual power supply. In this case at least two PDUs will be required to provide the primary and secondary power supplies. This is typical for data centre and high importance communication rooms. Where racks are used to serve smaller locations and house a mixture of equipment and cabling then the requirement may be less. However, as networks and installations evolve over time the requirements change. There are a variety of types of sockets including IEC C13 & C19 type used throughout the world. Additionally there are country specific types, such as the UK (BS1363), Schuko and NFC French styles. Excel has Standard, Modular, Monitored and Managed PDUs to suit all requirements.

S9

Efficiency Measurements The more energy that is used in a data centre (or other facility) results in higher bills. These account for major ongoing costs in operation. Efficiency measurements are required to establish the performance of the data centre. Depending on the organisation or current trends these can be carried out in many different ways. The following two make the same comparison, just expressed in different ways.

Power Usage Effectiveness Power Usage Effectiveness (PUE) compares the energy used directly for the computer equipment with the total power used in the facility. The calculation is a simple formula:

PUE =

Total Facility Energy IT Equipment Energy

Total Facility Energy is a measure of all energy used including that consumed by the IT equipment. This includes, measuring the energy consumed as electricity, gas etc. IT Equipment Energy only relates to the energy used for the direction operation of the equipment. All energy measurements must be in the same units (or converted), for example kWh (kilowatt hours). The resulting number does not have units. The aim is to reduce the PUE, with a PUE of 1 meaning only the IT Equipment uses energy. The typical PUE is difficult to quantify. However, the aim should always to be below 2.

Data Centre Infrastructure Efficiency Data Centre Infrastructure Efficiency (DCIE) is the inverse of PUE and is expressed as a percentage. Therefore the formula is:

DCIE =

IT Equipment Energy Total Facility Energy

Using and recording the information that is supplied from the Excel Intelligent PDUs can help calculate the IT Equipment Energy usage, which in turn allows the PUE or DCIE to be calculated. Once the baseline figure is calculated steps can be put in place and the improvements may be measured.

160


www.excel-networking.com

Excel Modular PDU Range The Excel range of modular PDU’s introduce flexibility and design options to suit your power requirements. A range of socket modules are available which snap into the housing quickly, easily and securely without the need for tooling. 1. First choose the empty housing hardware:

No. of Modules Input Output Voltage Housed Connectivity Connectivity

Part Number 555-050

6

Optional

250V

Current Rating (Amps) 32A

2. Pick your choice of power modules to go into your chosen housing. You can mix and match socket styles to suit your requirements and be safe in the knowledge that you can change them at a future date with the ‘snap in’ connectivity. The Excel power modules may be added or removed safely without turning the power off. Installations of modular housing with empty positions is safe and makes provision for future power requirements without having to commit to the socket connectivity.

S9

See below for the list of modules available:

Part No. of Number Sockets

Feature

Output Voltage Connectivity

555-060

3

Fused

250V

16A

555-061

5

Fused

250V

555-062

4

Fused

250V

CONNECTIVITY KEY

Total Current Rating (Amps)

3 pin - BS1363

“Commando Style” IEC 60309

10A

C13 - IEC60320

16A

C19 - IEC60320

161


Excel Power Distribution

Excel Standard PDUs The Excel Standard PDUs are available in a variety of sizes and socket types. The horizontal PDUs have the mounting brackets at the front to allow attachment to the 19” profiles. The vertical PDUs have the mounting brackets at the rear to allow mounting to single 19” profile, side supports or flat surface. Note that vertical PDUs are sometimes referred to as Zero U, due to mounting outside of the vertical equipment mounting rails. A range of input connectivity plugs are available to support different installation environments. The IEC 60309 “Commando style” plugs are utilised in Data Centres and other locations where the total current load for the PDU will exceed the standard domestic plug rating (UK BS1363, Schuko, French NFC. etc). It is becoming more common in rack installations to use either the C13 or C19 IEC output sockets. Within the range there are also PDUs with C14 and C20 Input Plugs so that a PDU may be connected direct to a rack mounted UPS (Uninterruptible power supply).

Voltage

Current Rating (Amps)

Horizontal

250V

13A

ü

Horizontal

250V

13A

6

ü

Vertical

250V

13A

D13-6H-EXL

6

ü

Horizontal

250V

13A

D13-8-EXL

8

ü

Vertical

250V

13A

D13-10-EXL

10

ü

Vertical

250V

13A

D13-12-EXL

12

ü

Vertical

250V

13A

D13-6HF-EXL

6

ü

ü

Horizontal

250V

13A

D13-7HF-EXL

7

ü

ü

Horizontal

250V

13A

D13-8F-EXL

8

ü

ü

Vertical

250V

13A

D13-10F-EXL

10

ü

ü

Vertical

250V

13A

D13-12F-EXL

12

ü

ü

Vertical

250V

13A

D16-6H-EXL

6

ü

Horizontal

250V

16A

D16-8-EXL

8

ü

Vertical

250V

16A

D16-10-EXL

10

ü

Vertical

250V

16A

D16-12-EXL

12

ü

Vertical

250V

16A

D32-8-EXL

8

ü

Vertical

250V

32A

D32-10-EXL

10

ü

Vertical

250V

32A

D32-12-EXL

12

ü

Vertical

250V

32A

555-230

16

ü

Vertical

12

&4

250V

32A

555-231

20

ü

Vertical

16

&4

250V

32A

555-232

24

ü

Vertical

20

&4

250V

32A

D13-6HIEC-EXL

6

250V

13A

No. of Sockets

Switched

D13-4H-EXL

4

ü

D13-5H-EXL

5

D13-6-EXL

Part Number

S9

162

Filtered

Mounting Orientation

Horizontal

Input Connectivity

Output Connectivity


www.excel-networking.com

Voltage

Current Rating (Amps)

Horizontal

250V

13A

Vertical

250V

13A

10

Vertical

250V

13A

D13-12IEC-EXL

12

Horizontal

250V

13A

555-240

6

ü

Horizontal

250V

10A

555-241

8

ü

Vertical

250V

10A

555-242

10

ü

Vertical

250V

10A

555-243

12

ü

Vertical

250V

10A

555-245

6

ü

Horizontal

250V

16A

555-246

8

ü

Vertical

250V

16A

555-247

10

ü

Vertical

250V

16A

555-250

6

ü

Horizontal

250V

10A

555-251

8

ü

Vertical

250V

10A

555-252

10

ü

Vertical

250V

10A

555-253

12

ü

Vertical

250V

10A

555-083

8

Horizontal

250V

16A

555-084

9

Horizontal

250V

16A

555-092

6

ü

Horizontal

250V

16A

555-093

8

ü

Horizontal

250V

16A

555-097

6

Horizontal

250V

16A

555-098

8

Horizontal

250V

16A

Part Number

No. of Sockets

D13-6HIECF-EXL

6

ü

D13-8IECF-EXL

8

ü

D13-10IEC-EXL

Click here to view the full range

Switched

Filtered

Mounting Orientation

Input Connectivity

Output Connectivity

S9

CONNECTIVITY KEY

3 pin - BS1363

“Commando Style” IEC 60309

C13 - IEC60320

C19 - IEC60320

Universal - GST18

Schuko

French

IEC 60884

163


Excel Power Distribution

Excel Intelligent PDU Family The Excel Intelligent PDU Family offers a high specification portfolio of power distribution units that are designed to suit any environment, where monitoring or managing of information is required. Excel is able to offer a PDU with up to 48 sockets with any combination of socket type including UK, Schuko, C13, C19 etc. We design and build everything in the UK, and have developed a wide range of products that cover the whole scale from overall monitored products to individual socket monitoring and individual socket switching. With a turnaround of approx 10-14 days from order to manufacture and delivery, the Excel Intelligent PDU range provides total flexibility to allow you to build a solution that fits your individual requirement. From our experience there isn’t an Intelligent PDU’ of one size fits all’ so we provide you with a simple build configuration to get exactly what you need. however we can offer the Lite version off the shelf. Our range of intelligent products has been developed so they can work as individual masters or run as a master and slave system. We can have one master with up to 31 slaves, all from one IP address, reducing the requirement for multiple IP addresses. The Excel Intelligent PDU range also comes with free software making it a highly competitive solution allowing the user to monitor and report on up to 50 IP addresses with the software. In theory it is possible to have up to 1600 PDU’s each with up to 48 outlets per PDU, all from one free software licence. The Excel Intelligent PDU range provides billing quality accuracy to better than 1%, allowing the unit to be used in co-location centres for the monitoring and charging of power used.

S9

Our system is designed for use in both single and 3 phase systems and to that end is designed with one monitoring board, but with a meter board at the beginning where the input power flows through, allowing them to sample the power 4000 times per second. This enables the units to measure the power at every point on the sine wave providing a very accurate result. Most Intelligent PDUs available only sample between 200 and 250 volts, so results are not as accurate, particularly with RMS voltages. The meter board allows the unit to economically meter a 3 phase system, as it uses 3 meter boards, one per phase. If required the PDU can be split into 3 separate sections (for use in co-location facilities) and group the results for 3 separate users on the same power strip. Other possibilities are to measure both A and B feeds through one monitoring system. The Lite range are produced using a Neutrik connector, for the power cord, allowing the PDU to be adaptable for any environment.

164


www.excel-networking.com The Excel Intelligent PDU range is a highly flexible solution. All versions have a built-in Environmental centre which covers a series of functions. As standard the units have a local display which can be supplemented by an additional remote display that can be mounted on the front of a rack for easy reading.

IINT1 (Overall Monitoring)

INT 2 (Overall + Individual Socket Monitoring)

INT3 (Overall + Individual Socket Monitoring + Switching)

Rack Mount Vertical (0U)

ü

ü

ü

ü

Rack Mount Horizontal (1U+)

ü

ü

ü

ü

Mild Steel

Mild Steel

Mild Steel

Mild Steel

Powder Coated

Powder Coated

Powder Coated

Powder Coated

Mains Lead

HO7

HO7

HO7

HO7

Lead Length

3 Mtr

3 Mtr

3 Mtr

3 Mtr

-

48

48

42

IPLite

PDU Info

Construction Finish

Maximum Number of Sockets Socket Types

C13, C18, Uk, Schuko, Plus Other

C13 & C19

Electrical Characteristics Both

Both

Both

Single Phase Only

Main Input

85 - 265 VAC

85 - 265 VAC

85 - 265 VAC

85 - 265 VAC

Frequency

50 - 60 Hz

50 - 60 Hz

50 - 60 Hz

50 - 60 Hz

0 - 63 Amps

0 - 63 Amps

0 - 63 Amps

0 - 63 Amps

-

0 - 16 Amps

0 - 16 Amps

-

+/- 1% Typical

+/- 1% Typical

+/- 1% Typical

+/- 1% Typical

RMS Volts

ü

ü

ü

ü

RMS Amps

ü

ü

ü

ü

Kilowatts

ü

ü

ü

ü

Frequency

ü

ü

ü

ü

Power Factor

ü

ü

ü

ü

Internal PDU Temperature

ü

ü

ü

ü

Peak Voltage

ü

ü

ü

ü

Peak Current

ü

ü

ü

ü

kVA

ü

ü

ü

ü

kWh (Cumulative)

ü

ü

ü

ü

Kg/CO2 (Cumulative)

ü

ü

ü

ü

BTU/h (Cumulative)

ü

ü

ü

ü

KJ/h (Cumulative

ü

ü

ü

ü

Cost (Cumulative)

ü

ü

ü

ü

Single / Three Phase Options

Overall Meter Current Range Socket Current Range Overall Meter Accuracy

S9

Overall Meter Accuracy

165


Excel Power Distribution

IINT1 (Overall Monitoring)

INT 2 (Overall + Individual Socket Monitoring)

INT3 (Overall + Individual Socket Monitoring + Switching)

Class II

ü

ü

ü

ü

Billing Quality

ü

ü

ü

ü

Sampling Rate 4000 times a second

ü

ü

ü

ü

Amps

-

ü

ü

-

Watts -

-

ü

ü

-

VA

-

ü

ü

-

kWh (Cumulative)

-

ü

ü

-

Single / Three Phase Options

-

-

ü

-

Main Input

-

-

ü

-

SNMP v1, 2, 3.

ü

ü

ü

ü

HTML, HTTP, HTTPs

ü

ü

ü

ü

XML

ü

ü

ü

ü

Email Alerts

ü

ü

ü

ü

ü

ü

ü

ü

Fitted within PDU

ü

ü

ü

ü

Remote Display Option

ü

ü

ü

ü

IPLite

Overall Meter Accuracy

Individual Socket Measurement

Socket Control

S9

Connectivity

Daisy Chaining RS485 Modbus - 1 Master Upto 31 Slaves

Local RGB Display

Capability Only, Sensors Available separately

Environmental Sensor Temperature Sensor Port (Up to 8

ü

ü

ü

ü

Humidity / Temperature Sensor

ü

ü

ü

ü

Volt Free Contacts (3 Sets)

ü

ü

ü

-

Door Contacts

ü

ü

ü

-

Electronic Door Handle

ü

ü

ü

-

Card Reader / Pin Pads

ü

ü

ü

-

Sensors)

Cabinet Security Ports

166


www.excel-networking.com

Communications Protocols iPower PDUs can communicate using multiple methods, via web browser utilising the embedded web pages, these give you full access to all PDU functionality, enable the setup and configuring of the PDU, enable the user to view live data, set thresholds, and view alerts on Single and Multiple PDUs, SNMP, using our MiB file a customer can upload onto their own or third party software, this can be used to gather information, view live data, control PDUs and collate information and histrionics.

Linking iPDUs PDU’s can be linked together with RJ22 to RJ45 communication cables by simple daisy-chain interconnections through 3-way splitters utilising 2 wire RS485 interface. This allows the construction of a network of PDU’s, where the 1st PDU becomes the master and subsequent PDU’s are set to “slave” mode, up to a maximum of 1600.

When daisy chaining the units the following items are needed: IPT-500-553 (3 metre cable RJ45 to RJ22) or IPT-500-555 (5 metre cable RJ45 to RJ22)

S9

And:- IPT-500-500 (RJ45/RJ22 3 way connector)

Std Cat 5e Patch cable from Ethernet port to PC or ther device

Central Management Our own Application software SNMP PDU Agent is a free to use application software aimed at a small to medium installations where a full DCiM platform is not required, it can be installed on a local PC, this can talk to up to 50 IP Addresses, 1600 PDUs (Daisy Chained), and provide Full control and Monitoring, Creation of Thresholds and Alerts, Data and Event Logging, Graphical Information and a complete user interface. The PDUs also have the ability to communicate using XML and Telnet, Telnet again offers full control over the PDUs functionality and is ideally suited to the home automation market.

167


Excel Power Distribution Sensors To complement the PDU’s and create an environmental solution, there is a host of sensor options available for the system*. Some of these items:l Temperature Sensor – Up to 8 Temperature sensors can be connected to the PDU, via a dedicated Port. l Humidity / Temperature Sensor – A single combined Temperature and Humidity sensor can be connected to the PDU via

a dedicated port.

l Smoke, Fire, Water, Heat, + Any type of Sensor with a normally closed relay output can be connected to the any one of

the 3 sets of Voltage free contacts on the PDU (Not IPLite)

l Remote Display – A slave / remote display can be connected to the PDU for mounting elsewhere within the cabinet,

Door, Plinth etc. for ease of viewing cabinet status.

l Door Locks – Electronic Door Handles with a 12 VDC operating mechanism can be connected to the PDU, other voltages

can be connected but require additional hardware. (Not IPLite)

l Door Contacts – Door contacts can be connected to the PDU to provide alerts when a cabinet door is opened. (Not IPLite) l Keypads / Readers – The PDU also has a dedicated port for Wiegand 26 capable readers / pin pads. (Not IPLite)

*Some of these items are 3rd party technology, and this section is designed to show the capabilities available.

S9 Billing Quality The Intelligent PDUs provide a high level of accuracy to help plan capacity and also provide accurate costs for billing purposes, the Class II billing quality meter circuitry utilises a calibrated resistor, this is more accurate than current transformers used by some manufacturers and due to the current being drawn directly through the resister means that we can accurately measure the full AC waveform from Peak to Peak providing extremely accurate measurement of RMS Volts, RMS Amps, Power Factor, the accurate measurement of Power factor means we can correctly report values for Kilowatts and Kilowatt Hours, making billing and capacity planning straightforward, this along with other values of Peak Volts, Peak Amps, kVA, BTUs, Energy Cost and Kilograms of CO2. The unit can also be calibrated onsite to further improve accuracy, subject to extra costs and availability.

Warranty Excel offers a 5 year return to base guarantee on all there main line products, whereby the product will either be repaired or replaced at the manufacturers discretion. On being notified of a problem of an apparently defective product Excel reserves the right to send an engineer to site (if economically viable to evaluate the problem.) prior to the return. Products containing surge suppression items are limited to a 2 year return to base warranty. Products which have been abused, damaged or not used for their designated purpose are excluded from any warranty.

168


www.excel-networking.com Building your Excel Intelligent PDU

Excelthese Intelligent Structure Follow basic steps PDU to buildPart yourNumber Excel Intelligent PDU. Management Level

Outlets: quantity and type

INT1 = Local and remote overall powering INT2 = Local and remote overall and per socket monitoring INT3 = Local and remote overall and per socket monitoring and switching INT4 = Local and remote overall and per socket switching INT5 = Local and remote overall power monitoring to existing passive power units

UKL = UK 13A Left* UKR = UK 13A Right* SCH = Schuco C13 = 10A C19 = 16A C13L = 13A Locking C19L = 16A Locking

Length of lead and (T)op or (B)ottom – (just length for Horizontal)

555-1V-C14-INT1-xUKL-xxx-3T Phase and Orientation

Input & Power

1V = Single Phase Vertical 3V = 3 Phase Vertical 1H = Single Phase Horizontal 3H = 3 Phase Horizontal

C14 C20 UK SCH Com16 Com32 X

*Selecting Right - this it will mean the Earth Pin on the 3 pin plug is to the Right and the lead will be to the left, and if you choose Left the pin will be to the left and the lead will be to the right

= = = = = = =

10A 16A 13A 16A 16A (Commando) 32A (Commando) Open Ended

2nd outlet option, if a3rd and a 4th required, just insert additional requirements as before

S9

C13 - IEC60320 C19 - IEC60320

3 Pin - BS1363

BS1363 & C13 - IEC60320

Schuko

169


Excel Power Distribution

IntelligentPDU PDUs Available Local & remote overall power monitoring Local & remote overall and per socket monitoring Local & remote overall and per socket monitoring, and power switching

S9

Socket Types Any socket combination: C13, C19 and Schuko Locking Single or three phase 16 – 63 Amp Up to 48 sockets on one PDU

Features UK design and manufacturer Short leads times Daisy chain up to 32 units together - 1 IP address Environmental ports - 8 temperature sensors and humidity sensor 3 volt free contacts Door control for up to 2 doors Remote LCD display Accuracy

Control Web browser SNMP Mod-Bus Software (Free) Optional card reader port

170

www

1IP


www.excel-networking.com

Excel Desktop Power Distribution Units

Excel Desktop Power Distribution Units offer a convenient addition to the work place. Available with either UK or Schuko power sockets and options for 6c apertures to accept data outlets and USB power in a stylish anodised aluminium finish, the PDUs are easily fitted to the desktop with the supplied clamps.

S9

The Excel Desktop PDUs eliminate the need to scramble under the desk to connect up laptop and other power supplies. With the option of the 6c Apertures and the USB power points it increases the flexibility of any work area for the resident or casual occupant. The USB outlets supply up to 2.1 amps permitting phones and tablets to be charged. An illuminated master power switch is fitted to each PDU. The power leads are supplied separately to ensure that the correct length is selected. Features l Desktop mounting

l UK or Schuko Power Sockets

l USB Power Option

l Removable Power Cord

l Optional 6c Apertures

l Illuminated Master Power Switch

Part Number

UK Sockets

Schuko Sockets

USB Power

6c Apertures

Length

Height

Depth

166 mm

78 mm

91 mm

555-270

2

555-271

2

2

222 mm

78 mm

91 mm

555-272

2

4

282 mm

78 mm

91 mm

555-273

4

2

325 mm

78 mm

91 mm

555-274

4

4

386 mm

78 mm

91 mm

555-275

2

2

4

332 mm

78 mm

91 mm

555-276

4

2

4

436 mm

78 mm

91 mm

152 mm

78 mm

91 mm

555-280

2

555-281

2

2

208 mm

78 mm

91 mm

555-283

4

2

296 mm

78 mm

91 mm

555-284

4

4

348.5 mm

78 mm

91 mm

555-286

4

4

398 mm

78 mm

91 mm

2

171


Excel Power Distribution

S9

When compromised performance is not an option our rack solutions deliver style, flexibility and specification options each and every time. With integral cable management, doors to encourage maximum ventilation, up to1300kg load bearing, free next day UK delivery and 25 year warranty, you can be sure you are getting the best in performance when you choose an Environ rack from Excel.

Visit Environ: excel-networking.com/environ-racks 172

Section9 powerdistribution  
Section9 powerdistribution