Function Index

Transformer Protection

PCS-978 Transformer Protection The PCS-978 provides a full-scheme protection and control solution for any type of transformer as well as shunt reactor applications. The PCS-978 can be implemented across a variety of transformers including, two-winding, three-winding, and autotransformers.

PCS-974 Mechanical Protection The PCS-974 mechanical protection provides sixteen high-power-pickup binary inputs dedicated to the mechanical relays in field, so as to realize the mechanical tripping/alarm with or without time delay.

PCS-9671 Transformer Current Differential Protection The PCS-9671 is a numerical relay designed for the protection of two-winding or threewinding transformers with a maximum of three CT inputs. It also can be used to protect reactors or implemented as a stub current differential protection in a one-and-a-half breaker arrangement.

Function

PCS-974

PCS-9671

Transformer restrained current differential protection

87PT

87UT

Transformer DPFC differential protection

87DT

Reactor restrained current differential protection

87PR

Reactor unrestrained current differential protection

87UR

Reactor DPFC differential protection

87DR

Inrush blocking

CT saturation blocking

Overexcitation blocking

CT failure blocking

Amplitude compensation

Phase angle compensation

√ √

Restricted earth fault protection

REF

Winding differential protection

87W/87N

Inter-turn fault protection for reactor

32G/21G

Overexcitation protection

24

Four stage underfrequency protection

81U

Four stage overfrequency protection

81O

Mechanical protection based on high-power-pickup binary inputs

MR

Temperature protection

26

Phase-to-phase impedance protection

21P

Phase-to-ground impedance protection

21G

68

Phase overcurrent protection

67P, 50/51P

Neutral overcurrent protection

67NP, 50/51N

Power swing blocking

50/51Q

Phase overvoltage protection

59P

Ground overvoltage protection

59G

Positive-sequence undervoltage protection

27P

49

Breaker failure protection

50BF

Pole discrepancy protection

62PD

Phase overcurrent alarm element

50PAlm

Ground overvoltage alarm element

59GAlm

Thermal protection

Read more on the web www.nrelect.com

PCS-978

Transformer unrestrained current differential protection

Negative sequence overcurrent protection

66

Functional Code

Voltage and current drift auto adjustment

Frequency tracking

IDMT characteristic for overcurrent

CT failure supervision

VT failure supervision

Fault recorder

GPS clock synchronization (IRIG-B, SNTP, PPS, PPM)

Configurable I/O and LED

Programmable logic

Up to four Ethernet ports using IEC 61850, DNP 3.0 or IEC 60870-5103 over TCP/IP

Up to two serial ports using IEC 60870-5-103

Optional sampling Value & GOOSE module with six optical Ethernet ports using IEC 61850-9-2 and IEC 61850-8-1 GOOSE

Read more on the web www.nrelect.com