Kuroda Hi-Rotor

Page 170

AIR MOTOR INDIVIDUAL INSTRUCTION僡 Be sure to read them before use. Also refer to Par. "For Safety Use" and Common instructions.

QUALITY OF AIR

LUBRICATION

CAUTION

CAUTION 䮡

Oil Supply to lubricated air motors Set an air lubricator in the pneumatic circuit and supply Class 1 turbine oil ISO VG32 (containing no additive). Do not use other oils (spindle oil, machine oil, etc.), otherwise causing a damage to the sealed part. Oil Supply to Non-lubricated air motors The non-lubricated air cylinder can be used without lubrication, but can be used with lubrication. When using it with lubrcation, do not discontinus supplying oil. Otherwise, the applide lubricant may run off, somtimes resulting in an operation failure. When using a lubrcant, Class 1 turbine oil ISO VG32 (containing no additive) is recommended.

OPERATING ENVIRONMENT

Fit an air filter with filtration of 5༁ or fine.

Install an air dryer. Compressed air containing much drainage causese the operation failure of pneumatic equipment. install an air dryer, lower the temperature and reduce drainage.

Take proper countermeasures against sludge. If sludge produced in compressor oil enters pneumatic equipment, it will cause the operation failure of pneumatic equipment. It is recommendable to use compressor oil (NISSEKI FAIRCALL A68, IDEMITSU DAPHUNY SUPER CS68) featuring minimized sludge production or use a sludge filter or mist cleaner to prevint sludge from entering the pneumatic equipment.

Use at low temperature. When using pneumatic equipment at temperature of 5 ... or below, install an air dryer or take other countermeasures to prevent drainage and moisture in compressed air from freezing or solidifying.

DANGER 䮡

Do not use air motors in a exploseve environment.

WARNING 䮡

TAV3 Series TAV3䮝 -10

Do not use air motors in a corrosive environment. When using air mortors in a place attended with much dust, water drops or oil drops, tif bellows or other proper means to the piston rod. Foruse in a dusty plsace , use an air mortors with powerful scraper.

QUALITY OF AIR

TAV3䮝 -20 䮡

Screw for mounting accessories is left-handed screw. Special cautions shall be taken for mounting and removing.

Mounting accessores shall be fastened with forque of 20~24N.M for use.

WARNING 䮡

Using pure air. Compressed air containing corrosive fases, chemicals, salt, etc. causes a breakdown or operation failure, So do not use such air.

Bolt with hexagonal hole shall be fastened with torque of 1㨪1.6N.m for use.

TAV3䮝 -45 Screw for mounting accessories is right-handed screw. It shall be fastened with torque of 30㨪38N.m for use. 䮡 For mounting Foot type(L Type) attachment, the type with deceleration ratio Foot type of 1/1, 1/3, 1/5 interferes with manifold. After loosening a set screw of M5 manifold, it shall be mounted while manifold is Foot type rotated. 䮡

mounting bracket

640


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.