Control panels

Electric control panels and protections for pumps and motors

English Catalogue

PRODUCTION CONTROL OF ENERGY PRODUZIONE EAND CONTROLLO DELL’ENERGIA


Control panels

Electric control panels and protections for pumps and motors


“..we feel positive, look at our results...”


WHO WE ARE: • We a re a yo u n g, d y n a m i c a n d p ro g re s s i ve g ro u p o f p e o p l e a l wa y s s t r i v i n g f o r b e t t e r solutions • We h a ve m o re t h a n 4 0 ye a rs ex p e r i e n c e i n t h i s f i e l d a n d we c o n t i n u e t o g row • We a re m a r ke t l e a d e rs i n t h i s field in Italy • We a re a t t h e f o re f ro n t o f t h e wo r l d m a r ke t s a n d ex p o r t t o ove r 3 0 c o u n t r i e s W H AT W E D O : • Pa n e l s f o r e l e c t r i c p u m p s , b o o s t e r s e t s , s ewa ge wa t e r, f i re - f i g h t i n g / c o n s t a n t p re s s u re systems • P h o t ovo l t a i c a n d s o l a r s y s t e m s f o r wa r m wa t e r A DVA N TAG E S F O R O U R C U S TO M E R S : • S o l u t i o n s a n d p ro d u c t s a re completely client focused • Q u i c k s o l u t i o n s e r v i c e, q u i c k a n swe rs t o c l i e n t n e e d s , q u e r i e s , and enquiries • H i g h q u a l i t y a n d re l i a b i l i t y i n t h e u s e a n d m a i n t e n a n c e o f o u r p ro d u c t s , g u a ra n t e e d b y c o m p l i a n c e t o a l l t h e a p p l i c a b l e s t a n d a rd s c u r re n t l y i n f o rc e.


INDEX

Control panels Electric control panels and protections for pumps and motors

MANIERO'S CONTROL PANELS

2

SINGLE PHASE CONTROL PANELS Panels for 1 pump Panels for 2 pumps

3-12 13-16

THREEPHASE CONTROL PANELS Panels for 1 pump direct start Panels for 2 pumps direct start Panels for 3 pumps direct start Panels for 1 pump Star / Delta start starting Panels for 2 pumps Star / Delta start starting Panels for 3 pumps Star / Delta start starting Panels for 1 pump reactance starting Panels for 1 pump soft-start starting

23 24-28 29-30 31 32 33 34 35

DRY-CHECK CONTROL PANELS Presentation and general characteristics Panels for 1 pump Single-Phase Panels for 1 pump Three-Phase Panels for 1 pump Three-Phase Star / Delta start Starting Panels for 1 pump Three-Phase Reactance Starting

36 38 39 40 41

THREE-PHASE FIRE FIGHTING CONTROL PANELS ACCORDING TO UNI EN 12845

Presentation and general characteristics Service control panels Direct start control panels Star / Delta start control panel Motor pump control panel

43 44 45 46 47

COMPLEMENTARY DEVICES Accessories for alarm systems Phases control with alarm Electronic timers Exchangers and electronic modules Complementary devices and alarm modules Control level relays Exchangers for electric pumps Level sensors Float switches Electronic and mechanic pressure switches

49-50 51 52 53-54 55 56-57 58 59 62 60-61

ACCESSORIES FOR PANELS Timers and run hour meters Capacitors Voltmeters and ammeters Accessories

64-65 66 67 68

www.manieroelettronica.it

1


M AN I ER O ' S CO N T R O L PA N E L S

Maniero Elettronica is one of very few companies in the world that can supply more than 1100 models of panels, designed and realized upon this specific needs of the customers. We produce control panels with a power range from 0,37kW up to more than 132kW for 1 - 6 pumps or motors. Control panels with frequency inverter are the top of our range of products. The kind of control panels are presented in a specific catalogue. Every model of electronic panel with ammetric protection replaces the equivalent of 5-6 models of electromechanic panels thanks to the wide possibility of setting the ammetric protection. This allows to reduce the stock of about 60%. From page n. 36 you can find the Dry Check panels for the control of dry running without probes. All our panels are marked CE and are realized according to the ISO 9001:2000 certificate.

2


SINGLE PHASE PANELS

“...our objective is to meet the aspirations of our customers...”

www.manieroelettronica.it

3


THERMAL PROTECTION FOR 1 SINGLE-PHASE ELETRIC PUMP WITH THERMAL RELAY, CAPACITOR AND ILLUMINATED SWITCH

PM10/...kW-C-T-IL-2 Thermal Proctection for 1 single-phase eletric pump with Capacitor and Illuminated Switch

The thermal protections we propose are normally used to resolve the problem of singlephase submersed electric pumps that need, besides thermal protection, also a specific start-up capacitor and probably even an ON/OFF switch. Of course mains protection (circuit breaker etc.) is at installer's care.

A

RUN

COM

START

CONNECTION DIAGRAM

P B GENERAL CHARACTERISTICS:

ATTENTION: – Power supply ~ 50/60Hz 230V±10%; – External push-button for thermal protection reset; – Start up capacitor; – Illuminated switch; – Thermoplastic box; – Output with cable holder; – Protected to IP 55.

Only the following models are made in this version: - 231.33 - 231.34 - 231.35

A

P

B

PROTECTED TO IP55 (OPTIONAL):

OPERATING CONDITIONS:

– Switch cover, code 670.102; – Thermal relay cover, code 879.276.

– Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CAPACITOR

THERMAL PROTECTION

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

PM10/0,37kW-16C-4T-IL- 2

231.81

0,37

0,5

16μF

4A

0,5

210

115

70

PM10/0,37kW-20C-4T-IL- 2

231.82

0,37

0,5

20μF

4A

0,5

210

115

70

PM10/0,55kW-20C-6T-IL- 2

231.83

0,55

0,75

20μF

6A

0,5

210

115

70

PM10/0,55kW-25C-6T-IL- 2

231.84

0,55

0,75

25μF

6A

0,5

210

115

70

PM10/0,75kW-25C-7T-IL- 2

231.85

0,75

1

25μF

7A

0,5

210

115

70

PM10/0,75kW-30C-7T-IL- 2

231.86

0,75

1

30μF

7A

0,5

210

115

70

PM10/0,75kW-35C-7T-IL- 2

231.87

0.75

1

35μF

7A

0,5

210

115

70

PM10/1,1kW-35C-10T-IL- 2

231.88

1,1

1,5

35μF

10A

0,5

210

115

70

PM10/1,1kW-40C-10T-IL- 2

231.89

1,1

1,5

40μF

10A

0,5

210

115

70

PM10/1,1kW-40C-12T-IL- 2

231.90

1,1

1,5

40μF

12A

0,5

210

115

70

PM10/1,5kW-40C-13T-IL- 2

231.91

1,5

2

40μF

13A

0,5

210

115

70

PM10/1,5kW-45C-13T-IL- 2

231.92

1,5

2

45μF

13A

0,7

210

115

70

PM10/1,5kW-50C-13T-IL- 2

231.93

1,5

2

50μF

13A

0,7

210

115

70

PM10/2,2kW-70C-18T-IL

231.33

2,2

3

70μF

18A

0,9

175

200

95

PM10/2,2kW-75C-18T-IL

231.34

2,2

3

75μF

18A

0,9

175

200

95

PM10/2,2kW-80C-18T-IL

231.35

2,2

3

80μF

18A

0,9

175

200

95

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/marketing office. --- Maniero Elettronica reserves the right to improve its products without prior notice.

4

www.manieroelettronica.it


PROTECTIONS FOR 1 SINGLE-PHASE ELECTRIC PUMP WITH THERMAL RELAY, CAPACITOR AND CAM SWITCH

PM10/...kW-C-T-IC Thermal Protection for 1 singlephase electric pump with Capacitor and Cam Switch

P

START

A

RUN

COM

CONNECTION DIAGRAM

B

GENERAL CHARACTERISTICS: OPERATING CONDITIONS: – Power supply ~ 50/60Hz 230V±10%; – External push-button for thermal protection reset; – Start up capacitor; – Bipolar cam switch; – Operating motor light; – Thermoplastic box; – Protected to IP 50.

– Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CAPACITOR

THERMAL PROTECTION

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

PM10/0,37kW-16C-4T-IC

231.61

0,37

0,5

16μF

4A

0,7

175

200

110

PM10/0,37kW-20C-4T-IC

231.62

0,37

0,5

20μF

4A

0,7

175

200

110

PM10/0,55kW-20C-6T-IC

231.63

0,55

0,75

20μF

6A

0,7

175

200

110

PM10/0,55kW-25C-6T-IC

231.64

0,55

0,75

25μF

6A

0,7

175

200

110

PM10/0,75kW-25C-7T-IC

231.65

0,75

1

25μF

7A

0,7

175

200

110

PM10/0,75kW-30C-7T-IC

231.66

0,75

1

30μF

7A

0,7

175

200

110

PM10/0,75kW-35C-7T-IC

231.67

0,75

1

35μF

7A

0,8

175

200

110

PM10/1,1kW-35C-10T-IC

231.68

1,1

1,5

35μF

10A

0,8

175

200

110

PM10/1,1kW-40C-10T-IC

231.69

1,1

1,5

40μF

10A

0,8

175

200

110

PM10/1,1kW-40C-12T-IC

231.76

1,1

1,5

40μF

12A

0,8

175

200

110

PM10/1,5kW-40C-13T-IC

231.70

1,5

2

40μF

13A

0,8

175

200

110

PM10/1,5kW-45C-13T-IC

231.71

1,5

2

45μF

13A

0,8

175

200

110

PM10/1,5kW-50C-13T-IC

231.72

1,5

2

50μF

13A

0,8

175

200

110

PM10/2,2kW-70C-18T-IC

231.73

2,2

3

70μF

18A

1

175

200

110

PM10/2,2kW-75C-18T-IC

231.74

2,2

3

75μF

18A

1

175

200

110

PM10/2,2kW-80C-18T-IC

231.75

2,2

3

80μF

18A

1

175

200

110

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/marketing office. --- Maniero Elettronica reserves the right to improve its products without prior notice.

www.manieroelettronica.it

5


CONTROL PANELS AND STARTERS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH THERMAL PROTECTION

QMD10/...kW-T Direct start control panel for 1 single-phase electric pump with thermal protection

Single-phase panels for control of electric pumps are proposed with thermal or ammetric protection. Ammetric protection allows with a single model to cover a wider range with power from 0,37 kW to 2,2 kW. N.B: For more than one pump please contact our technical/ sales service

P

COM

A

RUN

START

CONNECTION DIAGRAM

B

GENERAL CHARACTERISTICS:

– Control panel with electronic components; – Power supply ~ 50/60Hz 230V ±10%; – Very low voltage input for external control from pressure or float switch; – Very low voltage input for pressure switch or minimum level float against dry run or too full; – Selector for pressure or minimum level float (contacts N.C.) or (contacts N.O.); – Mains pilot light; – Operating motor light; – Min-max water level alarm light; Selector for automatic-off-manual operation (the last control is not latched);

– General disconnecting switch with door lock; – External push-button for thermal protection reset; – Motor protection fuse; – Thermoplastic box – Protected to IP 50.

ELECTRONIC SPARE PARTS: – Mother board SMM1T, code 223.31; – Synoptic panel for IP55, code 316.06.

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

PROTECTED TO IP55 (OPTIONAL): – Switch cover, code 644.344; – Thermal relay cover, code 879.276.

TECHNICAL DATA AND OPERATING POWERS DIMENSIONS mm A

CODE

APPROX POWER AT 230V kW

QMD10/0,37kW-4T

232.21

0,37

0,5

4A

1,5

225

255

130

QMD10/0,55kW-6T

232.22

0,55

0,75

6A

1,5

225

255

130

QMD10/0,75kW-7T

232.23

0,75

1

7A

1,5

225

255

130

QMD10/1,1kW-10T

232.24

1,1

1,5

10A

1,5

225

255

130

QMD10/1,5kW-13T

232.25

1,5

2

13A

1,5

225

255

130

QMD10/2,2kW-18T

232.26

2,2

3

18A

1,5

225

255

130

* AMD10/0,37kW-4T

232.01

0,37

0,5

4A

0,8

180

200

100

* AMD10/0,55kW-6T

232.02

0,55

0,75

6A

0,8

180

200

100

* AMD10/0,75kW-7T

232.03

0,75

1

7A

0,8

180

200

100

* AMD10/1,1kW-10T

232.04

1,1

1,5

10A

0,8

180

200

100

* AMD10/1,5kW-13T

232.05

1,5

2

13A

0,8

180

200

100

* AMD10/2,2kW-18T

232.06

2,2

3

18A

0,8

180

200

100

MODEL

APPROX POWER AT 230V Hp

THERMAL PROTECTION

WEIGHT kg

DIMENSIONS mm B

DIMENSIONS mm P

* GENERAL CHARACTERISTICS: characteristics preset and operating conditions are the same as QMD10/...kW-T, but without “general disconnecting switch with door lock”.

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value.

6

www.manieroelettronica.it


CONTROL PANELS AND STARTERS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH THERMAL PROTECTION AND CAPACITOR

CONNECTION DIAGRAM

GENERAL CHARACTERISTICS:

A

P

START

– Power supply ~50/60Hz 230V ± 10%; – External push-button for thermal protection reset; – Start up capacitor dimensioned according to the motor power; – General disconnecting switch with door lock; – Operating motor light; – Thermoplastic box; – Protected to IP 50.

COM

Direct Start Control Panel for 1 single-phase electric pump with capacitor and thermal protection

RUN

QMD10/...kW-C-T

B

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

THERMAL PROTECTION

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

DIMENSIONS mm P

QMD10/0,37kW-16C-4T

232.61

0,37

0,5

16μF

4A

1,6

225

255

130

QMD10/0,37kW-20C-4T

232.62

0,37

0,5

20μF

4A

1,6

225

255

130

QMD10/0,55kW-20C-6T

232.63

0,55

0,75

20μF

6A

1,6

225

255

130

QMD10/0,55kW-25C-6T

232.64

0,55

0,75

25μF

6A

1,6

225

255

130

QMD10/0,75kW-25C-7T

232.65

0,75

1

25μF

7A

1,6

225

255

130

QMD10/0,75kW-30C-7T

232.66

0,75

1

30μF

7A

1,6

225

255

130

QMD10/0,75kW-35C-7T

232.67

0,75

1

35μF

7A

1,6

225

255

130

QMD10/1,1kW-35C-10T

232.68

1,1

1,5

35μF

10A

1,6

225

255

130

QMD10/1,1kW-40C-10T

232.69

1,1

1,5

40μF

10A

1,6

225

255

130

QMD10/1,5kW-40C-13T

232.70

1,5

2

40μF

13A

1,6

225

255

130

QMD10/1,5kW-45C-13T

232.71

1,5

2

45μF

13A

1,6

225

255

130

QMD10/1,5kW-50C-13T

232.72

1,5

2

50μF

13A

1,6

225

255

130

QMD10/2,2kW-70C-18T

232.73

2,2

3

70μF

18A

1,8

225

255

130

QMD10/2,2kW-75C-18T

232.74

2,2

3

75μF

18A

1,8

225

255

130

QMD10/2,2kW-80C-18T

232.75

2,2

3

80μF

18A

1,8

225

255

130

* AMD10/0,37kW-16C-4T

232.41

0,37

0,5

16μF

4A

1

180

200

100

* AMD10/0,37kW-20C-4T

232.42

0,37

0,5

20μF

4A

1

180

200

100

* AMD10/0,55kW-20C-6T

232.43

0,55

0,75

20μF

6A

1

180

200

100

* AMD10/0,55kW-25C-6T

232.44

0,55

0,75

25μF

6A

1

180

200

100

* AMD10/0,75kW-25C-7T

232.45

0,75

1

25μF

7A

1

180

200

100

* AMD10/0,75kW-30C-7T

232.46

0,75

1

30μF

7A

1

180

200

100

* AMD10/0,75kW-35C-7T

232.47

0,75

1

35μF

7A

1

180

200

100

* AMD10/1,1kW-35C-10T

232.48

1,1

1,5

35μF

10A

1

180

200

100

* AMD10/1,1kW-40C-10T

232.49

1,1

1,5

40μF

10A

1

180

200

100

* AMD10/1,5kW-40C-13T

232.50

1,5

2

40μF

13A

1

180

200

100

* AMD10/1,5kW-45C-13T

232.51

1,5

2

45μF

13A

1

180

200

100

* AMD10/1,5kW-50C-13T

232.52

1,5

2

50μF

13A

1

180

200

100

* AMD10/2,2kW-70C-18T

232.53

2,2

3

70μF

18A

1,5

225

255

115

* AMD10/2,2kW-75C-18T

232.54

2,2

3

75μF

18A

1,5

225

255

115

* AMD10/2,2kW-80C-18T

232.55

2,2

3

80μF

18A

1,5

225

255

115

* GENERAL CHARACTERISTICS: characteristics preset and operating conditions are the same as QMD10/...kW-T, but without “general disconnecting switch with door lock” and the addition of the “Start up capacitor”.

www.manieroelettronica.it

7


CONTROL PANELS AND STARTERS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH OVERLOAD CURRENT PROTECTION AND LEVEL CONTROL

QA/50B Direct Start Control Panel for 1 Single-Phase electric pump up to 2,2kW with Overload Current Protection

COM

A

RUN

START

CONNECTION DIAGRAM

B

P

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: - Electronic control panel; - Power supply ~ 50/60Hz 230V ±10%; - Very low voltage inputs for external control from pressure switch or float switch; - Very low voltage inputs for external control level from probes or pressure switch against dry running or too full - Selector for pressure switch or minimum level float (N.C. or N.O.) or in case of level sensor for filling or emptying; - Operating light (ON), or motor protected (flashing); - Selector for automatic-off-manual operation (the last control is not latched); - Electronic protection with adjustable current; – Delay cut-in the time about 3”; – Motor protection fuses; - General disconnecting switch with door lock; – Thermoplastic box; - Protected to IP50.

– KCC/...: capacitor connection kit (upon request according to the motor); see last IIIpages

ELECTRONIC SPARE PARTS: – Mother board 313.16 – Synoptic: QA/50B code 316.04; AA/50B code 316.14.

– MIC/1E-..V-2U in 3 versions: interface module for control from an external device having power supply 12V~ or 24V~ or 230V~ output free contacts. see last pages

OPERATING CONDITIONS:

NOTE: 2 floating switches can be used in place of the sensors 1 OFF and 1 ON.

– Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

PROTECTED TO IP55 (OPTIONAL): – Switch cover, code 644.344; –Thermal relay cover, code 644.345. (for model AA/50B).

TECHNICAL DATA AND OPERATING POWERS CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QA/50B

233.13

0,37 - 2,2

0,5 - 3

2

18

1,5

220

255

130

* AA/50B

233.03

0,37 - 2,2

0,5 - 3

2

18

1,5

220

255

115

MODEL

* GENERAL CHARACTERISTICS: characteristics preset and operating conditions are the same as QA/50B, but without “general disconnecting switch with door lock”.

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere. For possible variations to normal system, please contact our technical/ marketing office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

8

www.manieroelettronica.it


CONTROL PANELS AND STARTERS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH AMMETRIC PROTECTION

QMD10/2,2kW-A Direct start control panel for 1 single-phase electric pump up to 2,2kW with Ammetric protection

COM

START

A

P

RUN

CONNECTION DIAGRAM

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electronic control panel; - Power supply ~ 50/60Hz 230V ±10%; - Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage inputs for pressure switch or min. level float against dry run or too full; – Selector for pressure switch or minimum level float (contacts N.C. or N.O.); – Mains pilot light; – Operating motor light; – Protected motor light; – Min-max water level alarm light; – Selectors for automatic-off-manual operation (the last control is not latched); – Electronic protection with adjustable current and cut-in time; – Motor protection fuse; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box; – Output with cable holder; – Protected to IP 50.

– MCL/3S-90mm, code 221.30 (see last pages) level control module for 3 level sensor or 2 floats (filling or emptying); – MCL/2ST-90mm, code 221.02 (see last pages) level control module for 2 timed level sensor (filling or emptying);

PROTECTED TO IP55 (OPTIONAL):

N.B.: the modules MCL/3S and MCL/2ST have the function of replacing the pressure switch or the minimun level float.

ELECTRONIC SPARE PARTS:

– Switch cover, code 644.344; – Push button cover, code 644.345 (for models AMD10).

– Mother board, code 223.32 – Synoptic: QMD10/...,Code 316.09 AMD10/...,code 316.03.

– MIC/1E-…V-2U, (see last pages) interface module for control from an external device having power supply 12V~ or 24V~ or 220V~ output dry contacts (ex. electronic irrigation device) available in three models; – KCC/…: capacitor connection kit (on request depending on the chosen motor) (see last IIIpages).

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QMD10/2,2kW-A

233.15

0,37 - 2,2

0,5 - 3

2

18

1,5

220

255

130

* AMD10/2,2kW-A

233.05

0,37 - 2,2

0,5 - 3

2

18

1,5

220

255

115

* GENERAL CHARACTERISTICS: characteristics preset and operating conditions are the same as QMD10/2,2kW-A, but without “general disconnecting switch with door lock”.

www.manieroelettronica.it

9


ELECTROMECHANIC CONTROL PANELS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH THERMAL PROTECTION

QMDE10/...kW-T Direct Start Control Panel for 1 single-phase electric pump with Thermal protection

START

COM

A

P

RUN

CONNECTION DIAGRAM

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electromechanic control panel; – Power supply ~ 50/60Hz 230V±10%; – 24V input for external control from pressure or float switch; – Selector for automatic-off-manual operating; – Mains pilot light; – Operating motor light; – Protected motor light; – Contactor with thermal relay internally resetable; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 55.

– CLU2/3S-24V code 632.311 (see last pages): undecal base level control for 3 probes, and undecal base wired ZUC/CLU-3S code 225.23 (see page 71) it always must be bound together to the level control; – KCC/...: capacitor connection kit (as per request depending on the chosen motor, see page 69).

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

N.B: The addition of the level control module may require the change of the box, please consider an extra charge of Euro 20,00 price list.

TECHNICAL DATA AND OPERATING POWERS CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,5

2

4,5

4

340

235

160

0,75

4,5

5,8

4

340

235

160

6

8

4

340

235

160

APPROX POWER AT 230V Hp

MODEL

CODE

APPROX POWER AT 230V kW

QMDE10/0,37kW-T

232.81

0,37

QMDE10/0,55kW-T

232.82

0,55

QMDE10/0,75kW-T

232.83

0,75

1

QMDE10/1,5kW-T

232.85

1,1÷1,5

1,5÷2

9

13,5

4

340

235

160

QMDE10/2,2kW-T

232.86

2,2

3

14

16,5

4

340

235

160

NOTES: in general the value of the power rating is indicative. For a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/sales office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

10

www.manieroelettronica.it


QMD10/2,2kW-A-SMP Direct start Control panel for 1 single-phase electric pump up to 2,2kW with Ammetric protection and Preset Mother Board

CONTROL PANELS FOR 1 230V SINGLE-PHASE ELECTRIC PUMP WITH AMMETRIC PROTECTION AND PRESET MOTHERBOARD The panels equipped with pre-configured motherboards offer maximum application flexibility, not only for present requirements, but for future needs too, as the standard board is already configured for use with the modules included in the catalogue (alarms, level gauges, exchangers, etc.). The addition of modules is already envisaged at the motherboard design stage and the modules are powered by the same board. This means several modules can be combined, with considerable financial savings and a much more compact design than when different items of complementary, self-powered equipment are used together

CONNECTION DIAGRAM

P

COM

RUN

START

A

B

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply ~ 50/60Hz 230V±10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage inputs for pressure switch or min. level float against dry run or too full; – Selector for pressure switch or minimum level float (contacts N.C. or N.O.); – Mains pilot light; – Operating motor light; – Protected motor light; – Min-max water level alarm light; – Selectors for automatic-off-manual operation (the last control is not latched); – External push button for overload current protection reset; – Electronic protection with adjustable current and cut-in time; – Motor protection fuse; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

DESIGNED FOR FITTING OF: – MA/1-300 code 221.24 (see last pages): IIIexternal alarm control module for lack of IIIwater or motor protection cut-in; – MCL/3S-300 code 221.05 (see last pages): IIIlevel control module for 3 level sensor or 2 IIIfloats (filling or emptying); – MCL/2ST-300 code 221.04 (see last pages); control module for 2 timed level sensors (filling or emptying); – KCC/…: capacitor connection kit (on request depending on the chosen motor see last IIIpages); – MR/ED-120”-400 code 221.12 (see last IIIpages): delayed module for switch on and switch off of the electric pump adjustable from 0 to 120”.

PROTECTED TO IP55 (OPTIONAL): – Switch cover, code 644.344; – Push button cover, code 644.345.

ELECTRONIC SPARE PARTS – Mother board SMPM1A, code 223.36; – Synoptic panel for IP55, code 316.03.

N.B.: The modules MCL/3S and MCL/2ST have substitutional function of the pressure switch or minimum level float.

OPERATING CONDITIONS – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QMD10/2,2kW-A-SMP

233.25

0,37 - 2,2

0,5 - 3

2

18

1,7

280

200

130

www.manieroelettronica.it

11


SINGLE-PHASE CONTROL PANELS FOR SEWAGE WATER

QMD10/...kW-A-AR Single-phase direct start control panel for 1 electric pump with ammetric protection for sewage water

In the specific case of the waste-water drainage sector, we offer control panels for singlephase electric pumps which can operate with either sensors or bulb floating switches, or with normal floating switches. As usual, please feel free to contact our technical/sales assistance if you have any questions.

RUN

CONNECTION DIAGRAM

A

ALARM

P

B

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply ~ 50/60Hz 230V±10%; – Very low voltage input from n°3 bulb float IIIswitches (stop, start, level alarm); – N°1 very low voltage input for motor thermal switch or N.C.. sensor; – Selector for pressure switch or minimum level float (contacts N.C. or N.O.); – Main pilot light ; – Operating motor light; – Protected motor light; – Min/Max water level alarm light; – Selector for automatic-off-manual operation (the last control is not latched ); – External push button for overload current protection reset; – Electronic protection with adjustable current and cut-in time; – Motor protection fuse; – Auxiliary protection fuse; – 24Vac output alarm. Alarm is active in case of intervention of overload or max level protection; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP50.

DESIGNED FOR FITTING OF:

PROTECTED TO IP55 OPTIONAL:

– KCC/…: Wired capacitor kit (on request, depending on the chosen motor); – MR/ED-120”-400 code 221.12 (see last pages) module for switch on and switch off of the electric pump adjustable from 0 to 120”.

– Switch cover, code 644.344; – Push button cover, code 644.345.

ELECTRONIC SPARE PARTS: – Mother board, code 223.36; – Synoptic, code 316.03.

OPTIONAL: – KIT/DS10M code 272.53 KIT Sensor device kit for 1 motor: detects the presence of water in the oil chamber, with motor shutdown in the event of detection. Supplied with relative warning lamp and alarm output;

OPERATING CONDITIONS:

N.B: the addition of this module requires the change of the box with an increase in price, ask to our technical / sales office.

- Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

QMD10/2,2kW-A-AR

12

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

272.30

0,37 - 2,2

0,5 - 3

2

18

1,7

265

200

130

www.manieroelettronica.it


ELECTROMECHANIC CONTROL PANELS FOR 2 230V SINGLE-PHASE ELECTRIC PUMPS WITH THERMAL PROTECTION

QMDE20/...kW-T Single-phase electromechanic control panel for 2 electric pumps with thermal protection

START

RUN

COM

START

A

RUN

COM

CONNECTION DIAGRAM

MIN

P

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electromechanic control panel; – Power ~ 50/60Hz 230V ± 10%; – Very low voltage inputs for external control iiiifrom pressure switches or float switches; – Very low voltage inputs for minimum pressure switch or float switch to prevent dry running or too full; – Selectors for automatic-off-manual modes; – Power signal lamp; – 2 motor running signal lamps; – 2 motor thermal overload protection signal lamps; – Contactors with internal reset thermal relays; – Protection fuses for each motor; – Protection fuses for auxiliary circuits; – Main disconnecting switch with door lock; – Thermoplastic enclosure; – Protected to IP 55.

– SU2/24V code 251.72 (see last pages): exchanger on undecal base for 2 electric pumps, plus wired undecal base; – ZUC/SU2 code 225.22 (see last pages) which IIImust always be fitted in conjunction with the exchanger.

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,5

3

4,5

6

430

315

160

0,75

4,5

5,8

6

430

315

160

6

8

6

430

315

160

1,5÷2

9

13,5

6

430

315

160

3

14

16,5

6

430

315

160

APPROX POWER AT 230V Hp

MODEL

CODE

APPROX POWER AT 230V kW

QMDE20/0,37kW-T

232.91

0,37

QMDE20/0,55kW-T

232.92

0,55

QMDE20/0,75kW-T

232.93

0,75

1

QMDE20/1,5kW-T

232.94

1,1÷1,5

QMDE20/2,2kW-T

232.95

2,2

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/marketing office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

www.manieroelettronica.it

13


QMD20/...kW-T-SI-2 Direct Start Control Panel for 2 single-phase electric pumps with Thermal protection and integrated Exchanger

CONTROL PANELS AND STARTERS FOR 2 SINGLEPHASE ELECTRIC PUMPS WITH THERMAL PROTECTION AND INTEGRATED EXCHANGER

COM

RUN

A

COM

RUN

CONNECTION DIAGRAM

MIN

P

B

GENERAL CHARACTERISTICS:

– Control panel with electronic components; – Power supply ~ 50/60Hz 230...240Vca ±10%; – Very low voltage inputs for external control from pressure switches or float switches; – Very low voltage input for external control by float or pressure switch for “minimum level control” against dry running or too full; – Micro selector for float or pressure switch for minimum level control (contacts NC or contacts NO); – Delayed SL/SP2 triggering from 0 to 4 seconds regulated by micro switches; – 0,5s delay to avoid repeated switchovers caused by the fluctuation of the floating switches;

– Sequence exchanger for motor starting integrated on the electronic card (possibility to exclude with selectors); – Sequential start-up of the motors; – Main pilot light; – Min-max level alarm light; – N. 2 operating motor lights; – Selector for automatic-off-manual operation (the last control is not latched); – External push-button for thermal protection reset for each motor; – Auxiliary circuits protection fuse; – Motor protection fuses; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

DESIGNED FOR FITTING OF: To increase the characteristics of the QMD20/.. kW-T-SI-2 control panel – MSM/Q20-SI-2 code 221.80 (see bottom of the page); – MA/1-100 code 221.23 (see page 55) if MSM/ Q20-SI-2 is present. PROTECTED TO IP55 OPTIONAL: – Switch cover, code 644.344; – Thermal relay cover, code 879.276. ELECTRONIC SPARE PARTS: – Mother board SM/QMD20-SI-2 code 219.66 – Synoptic panel for IP55, code 316.12.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 230V Hp

THERMAL PROTECTION

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,37

0,5

4A

1,6

265

200

130

0,55

0,75

6A

1,6

265

200

130

245.33

0,75

1

7A

1,6

265

200

130

QMD20/1,1kW-10T-SI-2

245.34

1,1

1,5

10A

1,6

265

200

130

QMD20/1,5kW-13T-SI-2

245.35

1,5

2

13A

1,6

265

200

130

QMD20/2,2kW-18T-SI-2

245.36

2,2

3

18A

1,6

265

200

130

MODEL

CODE

APPROX POWER AT 230V kW

QMD20/0,37kW-4T-SI-2

245.31

QMD20/0,55kW-6T-SI-2

245.32

QMD20/0,75kW-7T-SI-2

MSM/Q20-SI-2

Motherboard module for control panels with 2 electric pumps with integrated exchanger

The module allows to wide the range of functions as described here below: GENERAL CHARACTERISTICS:

– Controlled drop out of the SL/SP1 and SL/SP2 from 3 to 60s by means of micro switches located on the motherboard; – Enable selector for bulb float switches (SL1 and SL2 start the motors SL min

14

switches them off); – Recording of the thermal overload protection cutting in (only with the exchange function switched on); – Intervention of the second motor if the working motor stops because of the www.manieroelettronica.it

thermal overload protection cutting in; – Supplied with a mounting support; MSM/Q20-SI-2 cod .221.80.


QMD20/...kW-A-SMP Direct start Control panel for 2 single-phase electric pumps up to 2,2kW with Ammetric protection and Preset Mother Board

CONTROL PANELS FOR 2 SINGLE-PHASE 230V ELECTRIC PUPS WITH AMMETRIC PROTECTION AND PRESET MOTHERBOARD Pre-configured motherboards offer maximum application flexibility, not only for present requirements, but for future needs too, as the standard board is already set up for use with the modules included in the catalogue (alarms, level gauges, exchangers, etc.). The addition of modules is already envisaged at the motherboard design stage and the modules are powered by the same board. The use of several modules means considerable financial savings and a much more compact design when different items of complementary, self-powered equipment are used together.

CONNECTION DIAGRAM

P

RUN

COM

START

RUN

COM

START

A

B MIN

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply ~ 50/60Hz 230V±10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage inputs for external control from float or pressure switch against dry IIIrunning or too full; – Selector for pressure switch or minimum level float (contacts N.C. or N.O.); – Mains pilot light; – N°2 operating motor lights; – N°2 Protected motor lights; – Min-max water level alarm light; – Selectors for automatic-off-manual operation (the last control is not latched); – External pushbutton for overload current protection reset; – Electronic protection with adjustable current and cut-in time; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

DESIGNED FOR FITTING OF: – MS20/R code 221.39 (see last pages): IIIexchanger module for 2 electric pumps (2ND IIIdelayed); – MA/1-300 code 221.24 (see last pages): IIIexternal alarm control module for lack of IIIwater or motor protection cut-in; – MCL/3S-300 code 221.05 (see last pages): IIIlevel control module for 3 level sensor or 2 IIIfloats (filling or emptying); – MCL/2ST-300 code 221.04 (see last pages); control module for 2 timed level sensors (filling or emptying).

PROTECTED TO IP55 (OPTIONAL): – Switch cover, code 644.344; – Push button cover, code 644.345.

ELECTRONIC SPARE PARTS – Mother board, code 223.46; – Synoptic, code 224.80.

N.B.: The modules MCL/3S and MCL/2ST have substitutional function of the pressure switch or minimum level float.

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

– KCC/…: capacitor connection kit (on request IIIdepending on the chosen motor see last IIIpages); – MR/ED-120”-400 code 221.12 (see last page): n° 2 delayed modules for switch on and switch off of the electric pump adjustable from 0 to 120”.

TECHNICAL DATA AND OPERATING POWERS MODEL

QMD20/2,2kW-A-SMP

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

233.96

0,37 - 2,2

0,5 - 3

2

18

3,8

420

315

160

www.manieroelettronica.it

15


CONTROL PANELS FOR 2 230V ELECTRIC PUMPS FOR SEWAGE WATER

QMD20/...kW-A-AR Single-phase Direct start-up Control panel for 2 electric pumps with Ammetric protection for Sewage water

Especially designed for the waste water drainage sector, the series of control panels for single-phase and three-phase electric pumps can work with probes, bulb floats and normal floats. For any special requirements, please contact our technical/sales service as usual.

ALARM

MIN

P

MAX 1

RUN

COM

START

RUN

A

COM

START

CONNECTION DIAGRAM

ALARM

MAX 2

B IT IS POSSIBLE TO CONNECT LEVEL SENSORS IN PLACE OF THE FLOAT SWITCHES

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply input ~50/60Hz 230V±10%; – Very low voltage inputs for external controls from probes, bulb floats or float/pressure switches; – Functioning with: a) 4 bulb floats: pumps stop, pump 1 start-up, pump 2 start-up, alarm; b) or 5 probes: common, pumps stop, pump 1 start-up, pump 2 start-up, alarm; c) or 3 float switches: pump 1 start-up, pump 2 start-up, alarm; – Very low voltage inputs for external control from probe or alarm switch; – Internal selector for probes, bulb floats or float switches. – Very low voltage inputs for the thermal button or N.C. contact temperature probes.

– N° 4 trimmers to set the level probes IIIsensibility; – Main pilot light; – N° 2 motor running lights; – N° 2 protection cut in lights (ammetric); – Max level alarm light; – Selectors for automatic-off-manual operation (the last position is not latched); – Adjustable current and cut in delay electronic protection circuits; – Push-button for protection reset; – Internal selector to disable max alarm signal; – 24V~1A fuse protected alarm output; – Exchanger supplied standard on the 2 electric pumps (the 2nd pump is 2 seconds delayed); – Motor protection fuses; – Auxiliary circuits protection fuse; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP50.

OPTIONAL: – KIT/DS20M code 272.54 KIT Sensor device kit for 2 motors: it detects the presence of water in the oil chamber, with motor shutdown in the event of detection. Supplied with relative warning lamp and alarm output. N.B: the addition of this module requires the change of the box with an increase in price, ask to our technical / sales office.

ELECTRONIC SPARE PARTS: – Mother board, code 219.15; – Synoptic, code 224.80.

PROTECTED TO IP55 OPTIONAL:

OPERATING CONDITIONS:

– n. 2 switches cover, code 644.344; – n. 1 push button cover, code 644.345.

– Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

QMD20/2,2kW-A-AR

16

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

245.97

0,37 - 2,2

0,5 - 3

2

18

6

420

315

160

www.manieroelettronica.it


THREEPHASE PANELS

“...even if the problem seems impossible to solve , we always seek out a solution for our customers...”

www.manieroelettronica.it

17


PROTECTIONS FOR 1 THREEPHASE 400 V ELECTRIC PUMP

PT10/...kW-T-IMA Thermal Protection for 1 Three-Phase electric pump with Switch On-Switch Off

Three-phase protection is proposed for all the requirements of motor-driven pumps and motors with start/stop push button and, if required, connecting the neutral to a 230 V remote control. The mains protection (circuit breaker etc.) is at installer's care.

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Power supply 3~ 50/60Hz 400V±10%; – 400V contactor coil; – Switch on-switch off; – Contactor with thermal protection externally resetable; – Thermoplastic box; – Protected to IP 65.

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,37

0,5

0,9

1,3

0,8

200

90

155

0,55

0,75

1,4

1,9

0,8

200

90

155

244.43

0,75 - 1,1

1 - 1,5

2

3

0,8

200

90

155

PT10/1,5kW-T-IMA

244.44

1,5

2

3

4,5

0,8

200

90

155

PT10/2,2kW-T-IMA

244.45

1,8 - 2,2

2,5 - 3

4,5

5,8

0,8

200

90

155

PT10/3,7kW-T-IMA

244.46

3 - 3,7

4-5

6

8

0,8

200

90

155

PT10/5,5kW-T-IMA

244.47

4 - 5,5

5,5 - 7,5

9

13,5

0,8

200

90

155

PT10/7kW-T-IMA

244.48

6-7

8 - 9,5

13

16,5

0,8

200

90

155

PT10/10kW-T-IMA

244.49

7,5 - 10

10 - 14

17

22

0,8

235

110

170

PT10/13,5kW-T-IMA

244.50

11 - 13,5

15 - 18

24

29

0,8

235

110

170

CODE

APPROX POWER AT 230V kW

PT10/0,37kW-T-IMA

244.41

PT10/0,55kW-T-IMA

244.42

PT10/1,1kW-T-IMA

MODEL

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/sales office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

18

www.manieroelettronica.it


CONTROL PANELS FOR 1 THREEPHASE ELECTRIC PUMP WITH THERMAL PROTECTION

QTDE10/...kW-T Electromechanic Direct start Control panel for 1 Three-phase electric pump with Thermal protection

Three-phase panels for control of 1-4 electric pumps are proposed with thermal or ammetric protection. Ammetric protection allows with a single model to cover 50/60% of the range of the correspondent thermal protection panels with power from 0,37 kW to 22 kW .

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electromechanic control panel; – Power supply 3~ 50/60Hz 400V ±10%; – 24V voltage inputs for external control from pressure switch or float switch; – Cam switch for automatic-off-manual working; – Main pilot light; – Motor operator light; – Protected motor light; – Motor protection fuses; – Contactor with thermal relay internally resetable; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box (up to 16kW) or metal box (from 18,5kW to 22kWHp); – Protected to IP 55.

– CLU/3S-24V code 632.311 (see last pages): undecal base level control for 3 probes, more undecal base wired ZUC/CLU-3S code 225.23 (see page 71) it always must be bound together to the level control.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

N.B: The addition of the level control module from 7kW to 10kW requires the change of the box. Please consider an increase of Euro 20,00 price list. For panels over 10 kW contact our technical / sales dep.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,37

0,5

0,9

1,3

4

340

235

160

0,55

0,75

1,4

1,9

4

340

235

160

0,75 - 1,1

1 - 1,5

2

3

4

340

235

160

2

3

4,5

4

340

235

160

2,5 - 3

4,5

5,8

4

340

235

160

6

8

4

340

235

160

5,5 - 7,5

9

13,5

4,2

340

235

160

8 - 9,5

14

18

4,2

340

235

160

7,5 - 10

10 - 14

17

22

4,2

340

235

160

11 - 13,5

15 - 18

20

29

5,5

430

315

165

35

5,5

430

315

165

45

11,5

450

340

185

11,8

450

340

185

MODEL

CODE

APPROX POWER AT 230V kW

QTDE10/0,37kW-T

235.21

QTDE10/0,55kW-T

235.22

QTDE10/1,1kW-T

235.23

QTDE10/1,5kW-T

235.24

1,5

QTDE10/2,2kW-T

235.25

1,8 - 2,2

QTDE10/3,7kW-T

235.26

3 - 3,7

4-5

QTDE10/5,5kW-T

235.27

4 - 5,5

QTDE10/7kW-T

235.28

6-7

QTDE10/10kW-T

235.29

QTDE10/13,5kW-T

235.30

QTDE10/16kW-T

235.33

15 - 16

20 - 22

28

QTDE10/18,5kW-T

235.31

18,5

25

35

QTDE10/22kW-T

235.32

22

30

46

56

For QTDE10/ from 30kW to 132kW contact our technical/sales office

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/sales office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

www.manieroelettronica.it

19


CONTROL PANELS AND STARTERS FOR 1 THREE-PHASE ELECTRIC PUMP DIRECT STARTWITH AMMETRIC PROTECTION AND LEVEL CONTROL

QA/60C Direct Start Control Panel for 1 Three-Phase electric pump with Overload Current Protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS: PROTECTED TO IP55 (OPTIONAL): – Electronic control panel; – Power supply 3~ 50/60Hz 400V ±10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage inputs for external control for level sensors float or pressure switch for minimum level control against dry run or too full; – Selector for level probes (contacts N.C. for emptying, N.O. for filling); – Selector switches for the full scale of the sensor cut-in threshold adjustment trimmer (2-20k ; 10-100K); – Trimmer for sensor cut-in threshold adjustment; – Trimmer to regulate the delay of the ammetric protection (overload): the delay in triggering time is approximately 3 s; – Selector for automatic-off-manual operation (the last control is not latched); – Operating motor light (on), or motor protected (flashing);

– Motor protection fuses; – Auxiliary protection fuses – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

– Switch cover, code 644.344; – Push button cover, code 644.345 (for models AA). ELECTRONIC SPARE PARTS: – For model QA/60C, QA/61C, QA/62C: • Mother board SM/QA60C code 223.51;

DESIGNED FOR FITTING OF:

– For model QA/63C, QA/64C, QA/65C: • Mother board SM/QA63C code 223.61;

– MIC/1E-..V-2U in 3 versions (see last pages): interface module for control from an external device having power supply 12V~ or 24V~ or 230V~ output free contacts; For models QA/60C and QA/61C the change iiiiof box is required

– Synoptic panel for IP55 code 316.04. OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

NOTE: 2 float switches can be used in place of the floats 1 of OFF and 1 of ON.

TECHNICAL DATA AND OPERATING POWERS

20

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

2

8

1,8

200

255

130

2

11

1,9

200

255

130

MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

QA/60C

235.75

0,55 - 3,7

0,75 - 5

QA/61C

235.76

0,55 - 5

0,75 - 7

QA/62C

235.77

0,55 - 7

0,75 - 9,5

2

16

2,7

240

315

160

QA/63C

235.78

7,5 - 10

10 - 14

16

22

2,8

240

315

160

QA/64C

235.79

7,5 - 13,5

10 - 18

16

29

2,8

240

315

160

QA/65C

235.80

7,5 - 16

10 - 22

16

34

4

400

315

165

www.manieroelettronica.it


CONTROL PANELS AND STARTERS FOR 1 THREE-PHASE ELECTRIC PUMP WITH AMMETRIC PROTECTION

QTD10/...kW-A Direct start control panel for 1 electric pump with ammetric protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electronic panel; – Power supply 3~ 50/60Hz 400V ± 10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage input for pressure switch or minimum level float against dry run or too full; – Selector for pressure switch or minimum level float (NC or NO contacts); – Mains pilot light; – Motor operating light; – Motor protected light; – Min/Max water level alarm light; – Selector for operation in automatic-off-manual (the last control is not latched); – Electronic protection with adjustable current and cut-in time; – Motor protection fuses; – Auxiliary protection fuse; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

DESIGNED FOR FITTING OF:

PROTECTED TO IP55 (OPTIONAL):

– MCL/3S-90 code 221.30 (see last pages): level control module, for 3 probes or 2 float switches (filling or emptying); – MCL/2ST-90 code 221.02 (see last pages): IIIlevel control module for 2 timed probes (filling IIIor emptying).

– Switch cover, code 644.344; – Push button cover, code 644.345 (for models ATD10).

ELECTRONIC SPARE PARTS:

N.B.: the modules MCL/3S and MCL/2ST have the function of replacing the pressure switch or the minimun level float;

– For models QTD10/3,7kW÷7kW-A • Mother board, Code 223.62; • Synoptic Code 316.09

– MIC/1E-..V-2U available in 3 versions (see iiiilast pages): interface module for control from iiiian external device with power supply 12V~ iiiior 24V~ or 230V~ output dry contacts. – MA/1-100 code 221.23 (see last pages): alarm signalling module for lack of water or motor protection cut-in.

– For models QTD10/10kW÷16kW-A QTD10/13,5kW-A, QTD10/16kW-A: • Mother board, Code 223.63; • Synoptic Code 316.07.

OPERATING CONDITIONS: – Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

8

1,8

230

255

130

11

2.6

230

255

130

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

QTD10/3,7kW-A

235,91

0,55 - 3,7

0,75 - 5

2

QTD10/5kW-A

235,92

0,55 - 5

0,75 - 7

2

QTD10/7kW-A

235,93

0,55 - 7

0,75 - 9,5

2

16

2,7

260

315

160

QTD10/10kW-A

235,94

7,5 - 10

10 - 14

16

22

2,8

260

315

160

QTD10/13,5kW-A

235,95

7,5 - 13,5

10 - 18

16

29

2,8

260

315

160

QTD10/16kW-A

235,96

7,5 - 16

10 - 22

16

34

4

430

315

165

MODEL

www.manieroelettronica.it

21


CONTROL PANELS FOR 1 THREE-PHASE ELECTRIC PUMP WITH AMMETRIC PROTECTION AND PRESET MOTHERBOARD

QTD10/...kW-A-SMP Direct start Control panel for 1 Three-phase electric pump with Ammetric protection and Preset Mother Board

Pre-configured motherboards offer maximum application flexibility, not only for present requirements, but for future needs too, as the standard board is already set up for use with the modules included in the catalogue (alarms, level gauges, exchangers, etc.). The addition of modules is already envisaged at the motherboard design stage and the modules are powered by the same board. The use of several modules means considerable financial savings and a much more compact design than when different items of complementary, self-powered equipment are used together.

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electronic panel; – Three-phase power supply 3~ 50/60Hz 400V ± 10%; – Very low voltage inputs for external control from pressure switch and float switch; – Very low voltage input for pressure switch or minimum level float switch against dry run or too full; – Selector for pressure switch or minimum level float (NC or NO contacts); – Mains pilot light; – Motor operating light; – Motor protected light; – Min/Max water level alarm light; – Selector for operation in automatic-off-manual (the last control is not latched); – Electronic protection with adjustable current and cut-in time; – Motor protection fuses; – Auxiliary protection fuse; – General disconnecting switch with door lock; – External push-button for overload current protection reset; – Thermoplastic box; – Protected to IP 50.

DESIGNED FOR FITTING OF: PROTECTED TO IP55 (OPTIONAL):

– MA/1-300 code 221.24 (see last pages): IIIalarm signalling module for lack of water or IIImotor protection cut-in; – MCL/3S-300 code 221.05 (see last pages): IIIlevel control module, for 3 probes or 2 IIIfloats (filling or emptying); – MCL/2ST-300 code 221.04 (see last pages): IIIlevel control module, for 2 timed probes (filling or emptying).

– Switch cover, code 644.344; – Push button cover, code 644.345.

ELECTRONIC SPARE PARTS: – Mother board, Code 223.67; – Synoptic, Code 316.03; – Ammetric protection module: • model up to 7kW MPA10/2-18-20 Code 221.55; • model from 10 to 16kW MPA10/16-36-20 Code 221.56.

N.B.: the modules MCL/3S and MCL/2ST have the function of replacing of pressure switch or minimun level float. – MR/ED-120”-400 code 221.12 (see last pages): n° 2 timed modules for IIIdelay in motor switch-on or switch-off IIIadjustable from 0-120”; – MTS/7 code 221.15 (see last pages): weekly IItimer module. N.B: The addition of this last module may require the change of the box.

TECHNICAL DATA AND OPERATING POWERS

22

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

DIMENSIONS mm A

CODE

APPROX POWER AT 230V kW

QTD10/3,7kW-A-SMP

236.11

0,55 - 3,7

0,75 - 5

2

8

3,6

350

235

160

QTD10/5kW-A-SMP

236.12

0,55 - 5

0,75 - 7

2

11

3,6

350

235

160

QTD10/7kW-A-SMP

236.13

0,55 - 7

0,75 - 9,5

2

16

3,7

350

235

160

QTD10/10kW-A-SMP

236.14

7,5 - 10

10 - 14

16

22

3,7

350

235

160

QTD10/13,5kW-A-SMP

236.15

7,5 - 13,5

10 - 18

16

29

4

350

235

160

QTD10/16kW-A-SMP

236.18

7,5 - 16

10 - 22

16

34

5

430

315

160

MODEL

www.manieroelettronica.it

WEIGHT kg

DIMENSIONS mm B

DIMENSIONS mm P


CONTROL PANELS FOR 1 THREE-PHASE ELECTRIC PUMP FOR SEWAGE WATER

QTD10/...kW-A-AR Direct start control panel for 1 electric pump with ammetric protection for sewage water

CONNECTION DIAGRAM

A

ALARM ALARM RUN

P

STOP

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electronic panel; – Power supply 3~ 50/60Hz 400V ± 10%; – Very low voltage inputs for external control from n°3 bulb floats (stop, start-up, level alarm ); – N°1 very low voltage input for the thermal button or N.C. contact temperature probes; – Selector for pressure switch or minimum level float (NC or NO contacts); – Mains pilot light; – Motor operating light; – Motor protected light; – Min/Max water level alarm light; – Selector for operation in automatic-off-manual (the last control is not latched); – External push-button for overload current protection reset; – Electronic protection with adjustable current and cut-in time; – Motor protection fuses; – Auxiliary protection fuses; – Alarm output 24V~. Alarm will activate in case of overload protection or max. level; – General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

ELECTRONIC SPARE PARTS: – MR/ED-120”-400 Code 221.12 (see last pages) module for delay in motor switch-on or switch-off adjustable from 0-120”.

– Mother board, Code223.67; – Synoptic, Code 316.03.

OPTIONAL :

OPERATING CONDITIONS:

– KIT/DS10T Code 272.50 Sensor device kit for 1 motor detects the presence of water in the oil chamber, with motor shutdown in the event of detection. it is supplied with relative warning lamp and alarm output.

– Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

PROTECTED TO IP55 (OPTIONAL): – Switch cover, code 644.344; – Push button cover, code 644.345.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTD10/3,7kW-A-AR

272.01

0,55 - 3,7

0,75 - 5

QTD10/5kW-A-AR

272.02

0,55 - 5

0,75 - 7

2

8

3,6

430

315

170

2

11

3,6

430

315

QTD10/7kW-A-AR

272.03

0,55 - 7

170

0,75 - 9,5

2

16

3,7

430

315

QTD10/10kW-A-AR

272.04

7,5 - 10

170

10 - 14

16

22

4,5

430

315

170

QTD10/13,5kW-A-AR

272.05

7,5 - 13,5

10 - 18

QTD10/16kW-A-AR

272.06

7,5 - 16

10 - 22

16

29

4,5

430

315

170

16

34

12

550

400

230

www.manieroelettronica.it

23


CONTROL PANELS AND STARTERS FOR 2 THREE-PHASE ELECTRIC PUMPS DIRECT START WITH THERMAL PROTECTION

QTDE20/...kW-T Electromechanic Direct start Control panel for 2 Three-phase electric pumps with thermal protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electromechanic control panel; – Power supply 3~ 50/60Hz 400V±10%; – Very low voltage inputs for external controls from pressure switches or float switches; – Very low voltage voltage inputs for pressure IIIswitch or minimum level float switch against iiidry running or too full; – Cam switch for automatic-off-manual IIIoperation; – Contactors with thermal relay internally IIIresetable; – Main pilot light; – N°2 operating motor lights; – N°2 protection motor lights; – Motors protection fuses;

– Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box (up to 10kW) or metal box (for other models); – Protected to IP 55.

DESIGNED FOR FITTING OF: – SU2/24V code 251.72 (see last pages): IIIexchanger on undecal base for 2 electric IIIpumps, more undecal base wired; – ZUC/SU2 code 225.22 (see last pages) it always IIImust be bound together to the exchanger.

N.B.: For filling operation with n. 3 bulb floats (n.1 stop and n.2 start-up) contact our technical/sales office for the specific wiring. OPERATING CONDITIONS – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,37

0,5

0,9

1,3

7

430

315

160

0,55

0,75

1,4

1,9

7

430

315

160

236.73

0,75 - 1,1

1 - 1,5

2

3

7

430

315

160

QTDE20/1,5kW-T

236.74

1,5

2

3

4,5

7

430

315

160

QTDE20/2,2kW-T

236.75

1,8 - 2,2

2,5 - 3

4,5

5,8

7

430

315

160

QTDE20/3,7kW-T

236.76

3 - 3,7

4-5

6

8

7

430

315

160

QTDE20/5,5kW-T

236.77

4 - 5,5

5,5 - 7,5

9

13,5

7

430

315

160

QTDE20/7kW-T

236.78

6-7

8 - 9,5

14

18

8

430

315

165

QTDE20/10kW-T

236.79

7,5 - 10

10 - 14

17

22

8

430

315

165

QTDE20/13,5kW-T

236.80

11 - 13,5

15 - 18

20

29

14,5

550

400

230

QTDE20/16kW-T

236.56

15 - 16

20 - 22

28

35

14,5

550

400

230

QTDE20/18,5kW-T

236.57

15 - 18,5

20 - 25

35

45

14,5

750

500

260

QTDE20/22kW-T

236.58

22

30

46

56

14,5

750

500

260

MODEL

CODE

APPROX POWER AT 230V kW

QTDE20/0,37kW-T

236.71

QTDE20/0,55kW-T

236.72

QTDE20/1,1kW-T

For QTDE20/ from 30kW to 132kW contact our technical/sales office NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/marketing office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

24

www.manieroelettronica.it


CONTROL PANELS AND STARTERS FOR 2 THREE-PHASE ELECTRIC PUMPS DIRECT START WITH THERMAL PROTECTION AND INTEGRATED EXCHANGER

QTD20/...kW-T-SI Direct Start control panel for 2 three-phase electric pumps with thermal protection and integrated exchanger

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply 3 ~ 50/60Hz 400V ± 10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage input for external control from pressure or float switches (N.O. contact) for minimum level control against dry run or too full; – Sequence exchanger for motor starting inside the electronic mother board; – N° 2 operating motor lights; – N° 2 protected motor lights; – Selectors for automatic-off-manual operation (the last control is not latched); – Contactors with thermal relay internally resetable; – Motors protection fuses; – Auxiliary protection fuses;

– General disconnecting switch with door lock; – Thermoplastic box; – Protected to IP 50.

ELECTRONIC SPARE PARTS:

PROTECTED TO IP55 (OPTIONAL):

OPERATING CONDITIONS:

– n. 2 switches cover, code 644.344.

– Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

– Mother board Code 223.71; – Synoptic, Code 316.11.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,37

0,5

0,9

1,3

4

340

235

160

0,55

0,75

1,4

1,9

4

340

235

160

0,75 - 1,1

1 - 1,5

2

3

4

340

235

160

2

3

4,5

4

340

235

160

2,5 - 3

4,5

5,8

4

340

235

160

6

8

4

340

235

160

5,5 - 7,5

9

13,5

4

340

235

160

8 - 9,5

14

18

4,5

420

315

165

7,5 - 10

10 - 14

17

22

5,5

420

315

165

11 - 13,5

15 - 18

20

29

5,5

420

315

230

20 - 22

28

35

5,5

550

400

230

MODEL

CODE

APPROX POWER AT 230V kW

QTD20/0,37kW-T-SI

245.81

QTD20/0,55kW-T-SI

245.82

QTD20/1,1kW-T-SI

245.83

QTD20/1,5kW-T-SI

245.84

1,5

QTD20/2,2kW-T-SI

245.85

1,8 - 2,2

QTD20/3,7kW-T-SI

245.86

3 - 3,7

4-5

QTD20/5,5kW-T-SI

245.87

4 - 5,5

QTD20/7kW-T-SI

245.88

6-7

QTD20/10kW-T-SI

245.89

QTD20/13,5kW-T-SI

245.90

QTD20/16kW-T-SI

245.91

15 - 16

www.manieroelettronica.it

25


CONTROL PANELS AND STARTERS FOR 2 THREE-PHASE ELECTRIC PUMPS DIRECT START WITH AMMETRIC PROTECTION

QTD20/...kW-A-2F Direct Start control panel for 2 three-phase pumps with Ammetric protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electronic control panel; – Power supply 3~ 50/60Hz 400V ± 10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage input for pressure switch or minimum level float against dry run or too full; – Selector for pressure or minimum level float (contacts N.C.) or (contacts N.O.); – Mains pilot light; – N° 2 operating motor lights; – N° 2 protected motor lights; – Min-max water level alarm light; – Selectors for automatic-off-manual operation (the last control is not latched); – External push-botton for ammetric protection reset; – Electronic protections with adjustable current and cut-in time; – Motors protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box (up to 7 kW) or metal box (from 10 kW to 16 kW); – Protected to IP 50.

ELECTRONIC SPARE PARTS:

– MA/1-100mm code 221.23(see last pages): external alarm control module for lack of motor protection cut-in; – MS20/R code 221.39 (see last pages): exchanger module for 2 electric pumps (2nd delayed).

– For model from 3,7kW to 7kW: • Mother board SM/QTD20-10-A, code 219.12; – For model from 10kW to16kW: • Mother board SM/QTD20-20A, code 219.13; – Synoptic, code224.78.

PROTECTED TO IP55 (OPTIONAL):

OPERATING CONDITIONS:

– n. 2 switches cover, code 644.344; – Push button cover, code 644.345.

– Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

26

CODE

APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR )

(FOR EACH MOTOR)

MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

kW

Hp

MIN

QTD20/3,7kW-A-2F

237.31

0,55 - 3,7

0,75 - 5

2

8

4,2

430

315

170

QTD20/5kW-A-2F

237.32

0,55 - 5

0,75 - 7

2

11

4,4

430

315

170

QTD20/7kW-A-2F

237.33

0,55 - 7

0,75 - 9,5

2

16

5,2

430

315

170

QTD20/10kW-A-2F

237.34

7,5 - 10

10 - 14

16

22

12

550

400

230

QTD20/13,5kW-A-2F

237.35

7,5 - 13,5

10 - 18

16

29

12

550

400

230

QTD20/16kW-A-2F

237.36

7,5 - 16

10 - 22

16

34

12

550

400

230

www.manieroelettronica.it


CONTROL PANELS AND STARTERS FOR 2 THREE-PHASE ELECTRIC PUMPS DIRECT START WITH AMMETRIC PROTECTION AND PRESET MOTHERBOARD

QTD20/...kW-A-SMP Direct Start control panel for 2 three-phase electric pumps with Ammetric protection and preset mother board

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electronic control panel; – Power supply 3~ 50/60Hz 230/400V ± 10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage input for pressure switch or minimum level float against dry run or too full; – Selector for pressure or minimum level float (contacts N.C.) or (contacts N.O.); – Mains pilot light; – N° 2 operating motor lights; – N° 2 protected motor lights; – Min-max water level alarm light; – Selectors for automatic-off-manual operation (the last control is not latched); – External push-botton for ammetric protection reset; – Electronic protection with adjustable current and cut-in time; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Thermoplastic box (until 5 kW), or metal box (from 7 to 16 kW); – Protected to IP 50.

PROTECTED TO IP55 (OPTIONAL): – MS20/R code 221.39 (see last pages): exchanger module for 2 electric pumps (2ND delayed); – MCL/3S-300 code 221.05 (see last pages): IIIlevel control module for 3 level sensors or 2 IIIfloats (filling or emptying); – MCL/2ST-300 code 221.04 (see last pages): level control module for 2 timed level sensor (filling or emptying). N.B.: the modules MCL/3S and MCL/2ST have the function of replacing the pressure switch or minimun level float. – MA/1-300 code 221.24 (see last pages): external alarm control module for lack of water or motor protection cut-in; – MR/ED-120”-400 code 221.12 (see last IIIpages): n° 2 timed modules for delay in motor switch-on or switch-off adjustable from III0III120”; – MTS/7 code 221.15 (see last pages): weekly timer module.

– n. 2 switches cover, code 644.344; – Push button cover, code 644.345. ELECTRONIC SPARE PARTS: – Mother board, code 223.78; – Synoptic panel, code 224.78; – Ammetric protection module: • models up to 7kW MPA20/2-18-15 code 221.57; • models from 10 to 16kW MPA20/16-36-15 code 221.58.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

N.B.: for some models, the addition of this last module may require the change of the box.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

kW

Hp

MIN

QTD20/3,7kW-A-SMP

237.51

0,55 - 3,7

0,75 - 5

2

8

5,1

430

315

170

QTD20/5kW-A-SMP

237.52

0,55 - 5

0,75 - 7

2

11

5,1

430

315

170

QTD20/7kW-A-SMP

237.53

0,55 - 7

0,75 - 9,5

2

16

14

550

400

230

QTD20/10kW-A-SMP

237.54

7,5 - 10

10 - 14

16

22

14

550

400

230

QTD20/13,5kW-A-SMP

237.55

7,5 - 13,5

10 - 18

16

29

14

550

400

230

QTD20/16kW-A-SMP

237.56

7,5 - 16

10 - 22

16

34

14

550

400

230

www.manieroelettronica.it

27


CONTROL PANELS FOR 2 THREE-PHASE ELECTRIC PUMPS FOR SEWAGE WATER

QTD20/...kW-A-AR Three-phase Direct start-up Control panel for 2 electric pumps with Overload Current protection for Sewage

Especially designed for the waste water drainage sector, the series of control panels for single-phase and three-phase electric pumps can work with probes, bulb floats and normal floats. For any special requirements, please contact our technical/sales service

CONNECTION DIAGRAM

A ALARM

ALARM 2 1

1

2

STOP

P

B

GENERAL CHARACTERISTICS:

– Electronic control panel; – Power supply 3~50/60Hz 230/400V±10%; – Very low voltage inputs for external controls from probes, bulb floats or float/pressure switches; – Functioning with: a) 4 bulb floats: pumps stop, pump 1 start-up, pump 2 start-up, alarm; b) or 5 probes: common, pumps stop, pump 1 start-up, pump 2 start-up, alarm; c) or 3 float/pressure switches: pump 1 start-up, pump 2 startup, alarm; – Very low voltage input for external alarm probe or float; – Internal selectors for probes, bulb floats or float/pressure switches; – very low voltage inputs for the thermal button or N.C. contact temperature probes; – N° 4 trimmers to set the level probes sensibility; – Main pilot light; – N° 2 motor running lights; – N° 2 protection cut in lights (ammetric); – Min-max level alarm light; – Selectors for automatic-off-manual operation (the last position is not latched); – Adjustable current and cut in delay electronic protection circuits; – Push-button for protection reset;

– Internal selector to disable min-max alarm signal; – 24V ~1A fuse protected alarm output; – Exchanger supplied standard on the 2 electric pumps (the 2nd pump is 2 seconds delayed); – Motors protection fuses; – Auxiliary circuits protection fuse; – General disconnecting switch with door lock; – Thermoplastic box (up to 7kW) or metal box (from 10 to 16kW); – Protected to IP50.

OPTIONAL: – KIT/DS20T code 272.51 KIT Sensor device kit for 1 motor detects the presence of water in the oil chamber, with motor shutdown in the event of detection. It is supplied with relative warning lamp and alarm output. N.B: the addition of this module requires the change of the box with an increase in price, ask to our technical / sales office.

ELECTRONIC SPARE PARTS: – Synoptic panel, code 224.78. – Level control module MCL/5S-AR, code 221.72; – For models from 3,7kW to 7 kW: • mother board SM/QTD20-10A-230V, code 219.14; – For models from 10kW to 16 kW: • mother board SM/QTD20-20A-230V, code 219.21.

PROTECTED TO IP55 (OPTIONAL):

– n. 2 switches cover, code 644.344; – Push button cover, code 644.345.

TECHNICAL DATA AND OPERATING POWERS MODEL

28

CODE

APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

kW

Hp

MIN

MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTD20/3,7kW-A-AR

236.41

0,55 - 3,7

0,75 - 5

2

8

5,1

430

315

170

QTD20/5kW-A-AR

236.42

0,55 - 5

0,75 - 7

2

11

5,1

430

315

170

QTD20/7kW-A-AR

236.43

0,55 - 7

0,75 - 9,5

2

16

5,6

430

315

170

QTD20/10kW-A-AR

236.44

7,5 - 10

10 - 14

16

22

14

550

400

230

QTD20/13,5kW-A-AR

236.45

7,5 - 13,5

10 - 18

16

29

14

550

400

230

QTD20/16kW-A-AR

236.46

7,5 - 16

10 - 22

16

34

14

550

400

230

www.manieroelettronica.it


CONTROL PANELS FOR 3 THREE-PHASE ELECTRIC PUMP WITH THERMAL PROTECTION

QTDE30/...kW-T Electromechanic Direct start Control panel for 3 Three-phase electric pumps with thermal protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electromechanic control panel; – Power supply 3~ 50/60Hz 400V±10%; – Very low voltage inputs from pressure switches or iiifloat switches; – Very low voltage inputs for external controls iiifrom pressure switch or minimum level float iiiswitch against dry running or too full; – Cam switches for automatic-off-manual working; – Contactors with thermal relay internally resetable; – Main pilot light; – N°3 operating motor lights; – N°3 protection motor lights; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Metal box; – Protected to IP 55.

floats (n.1 stop and n.3 start-up) contact our technical/sales office for the specific wiring.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

DESIGNED FOR FITTING OF: – SG4/230-400V code 251.77 (see last pages): Sequential exchanger for 3 electric pumps, wired on the control panels. – SU2/24V code 251.72 (see last pages): IIIexchanger on undecal base for 2 electric pumps, more undecal base wired ZUC/SU2 code 225.22 (see last pages) IIIit always must be bound together to the IIIexchanger;

For panels with more than 3 electric pumps contact our technical/sales office

N.B. For emptying operation with n. 4 bulb

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

kW

Hp

MIN

MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTDE30/0,37kW-T

237.91

0,37

0,5

0,9

1,3

13

550

400

230

QTDE30/0,55kW-T

237.92

0,55

0,75

1,4

1,9

13

550

400

230

QTDE30/1,1kW-T

237.93

0,75 - 1,1

1 - 1,5

2

3

13

550

400

230

QTDE30/1,5kW-T

237.94

1,5

2

3

4,5

13

550

400

230

QTDE30/2,2kW-T

237.95

1,8 - 2,2

2,5 - 3

4,5

5,8

13

550

400

230

QTDE30/3,7kW-T

237.96

3 - 3,7

4-5

6

8

13

550

400

230

QTDE30/5,5kW-T

237.97

4 - 5,5

5,5 - 7,5

9

13,5

13

550

400

230

QTDE30/7kW-T

237.98

6-7

8 - 9,5

14

18

13

550

400

230

QTDE30/10kW-T

237.99

7,5 - 10

10 - 14

17

22

13

550

400

230

QTDE30/13,5kW-T

237.89

11 - 13,5

15 - 18

20

29

16

750

500

260

QTDE30/16kW-T

237.90

15 - 16

20 - 22

28

35

16

750

500

260

QTDE30/18,5kW-T

237.88

18,5

25

35

45

40

850

600

260

For QTDE30/ from 22kW to 132kW contact our technical/sales office NOTES: The value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/marketing office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

www.manieroelettronica.it

29


CONTROL PANELS FOR 3 THREE-PHASE ELECTRIC PUMP WITH AMMETRIC PROTECTION

QTD30/...kW-A Direct start Control panel for 3 Three-phase electric pumps with ammetric protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS: DESIGNED FOR FITTING OF: – Electronic control panel; – Power supply 3~ 50/60Hz 400V±10%; – Very low voltage inputs for external controls from floats or pressure switches; – Very low voltage input for pressure switch or minimum level float against dry running or too IIIfull; – Selector for pressure or minimum level float (contacts N.C.) or (contacts N.O.); – Selector for the exclusion from the min. level float IIIswitch of any float; – Main pilot light; – N°3 operating motor lights; – N°3 protection motor lights; – Min-max level alarm light; – Selector for automatic-off-manual operation (the last position is not latched); – Adjustable current and cut in delay electronic protection circuits; – Push-button for protection reset; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Metal box; – Protected to IP 50.

– MS20/R code 221.39 (see last pages): IIIexchanger module of 2 electric pumps (2nd IIIdelayed); – MS40 code 221.40 (see last pages): exchanger module of 3 electric pumps (3nd delayed); – MA/1-300 code 221.24 (see last pages): IIIexternal alarm control module for lack of IIIwater or motor protection cut-in.

ELECTRONIC SPARE PARTS: – Mother board, code 223.53; – Synoptic panel, code 224.33; – Ammetric protection modules: • models up to 7kW: - MPA10/2-18-40 code 221.41; - MPA20/2-18-30 code 221.51; • models from 10 to 16kW: - MPA10/16-36-40 code 221.42; - MPA20/16-36-30 code 221.52.

PROTECTED TO IP55 (OPTIONAL): – N. 3 switches cover, code 644.344; – N. 1 push button cover, code 644.345.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

8

12,3

550

400

230

11

12,3

550

400

230

MODEL

CODE

kW

Hp

MIN

QTD30/3,7kW-A

238.11

0,55 - 3,7

0,75 - 5

2

QTD30/5kW-A

238.12

0,55 - 5

0,75 - 7

2

QTD30/7kW-A

238.13

0,55 - 7

0,75 - 9,5

2

16

12,3

550

400

230

QTD30/10kW-A

238.14

7,5 - 10

10 - 14

16

22

12,3

550

400

230

QTD30/13,5kW-A

238.15

7,5 - 13,5

10 - 18

16

29

13

750

500

260

QTD30/16kW-A

238.16

7,5 - 16

10 - 22

16

34

13

750

500

260

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/sales office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

30

www.manieroelettronica.it


QTSE10/...kW-T

CONTROL PANELS FOR 1 THREE-PHASE ELECTRIC PUMP STAR DELTA START WITH THERMAL PROTECTION

Electromechanic star-delta control panel for 1 three-phase electric pump with thermal protection

Control panels with star-delta and reactance start up are used when there are problems of high inrush current and limited installed power, or in certain cases where, above certain powers, direct start up is impossible. For this reason we offer standard control panels and star-delta and reactance starters (statoric) with a two step start. In this way, the electric pump is started gradually. With the first step the motor is started, supplying partial voltage, with the second mains voltage is supplied directly to the motor. N.B. For loads with a strong starting inertia (e.g.: fans, compressors, pumps, mills, crushers, etc.) contact our technical/ sales office.

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electromechanic control panel star-delta start ; – Power supply 3 ~ 50/60Hz 230/400V ± 10%; – Very low voltage input for external control from IIIpressure or float switch; – Cam switch for automatic/off/manual working; – Main pilot light; – Motor operating lights; – Protected motor light; – Contactors with thermal relay internally IIIresetable; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Star-delta exchange timer adjustable from 0 to 30”; – Thermoplastic box (up to 11kW) or metal box (from 15 to 135 kW); – Protected to IP 55.

DESIGNED FOR FITTING OF: – CLU2/3S-24V code 632.311 (see last pages): undecal base level control with III3 electrodes, plus undecal base wired; – ZUC/CLU-3S code 225.23 (see last pages) that must be always combined with this module.

ADDITIONAL VOLTMETER AND AMMETER KIT: K-V-A/2,2-5,5kW code 225.82 for models from 2,2 to 5,5 kW; K-V-A/7-10kW code 225.83 for models for 7,5 kW; K-V-A/11-22kW code 225.84 for models from 11 to 22 kW; K-V-A/30-55kW code 225.85 for models from 30 to 55 kW; K-V-A/59-75kW code 225.86 for models from 66 and 75 kW; K-V-A/90-150kW code 225.87 for models from 90 to 150 kW; (see last pages).

TECHNICAL DATA AND OPERATING POWERS CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

3

5

5,5

6

420

315

160

5,5

7,8

9

6

420

315

160

7,5

10

14

6

420

315

160

10

15

18

6

420

315

160

11

15

18

23

6

420

315

160

15

20

24

35

16

550

400

230

18,5

25

35

45

16

550

400

230

18,5 - 22

25 - 30

35

52

16

550

400

230

30

40

49

66

20

740

500

260

238.40

37

50

75

85

30

740

500

260

238.41

45

60

80

98

30

740

500

260

QTSE10/55kW-T

238.43

51 - 59

70 - 80

100

125

40

740

500

260

QTSE10/75kW-T

238.46

66 - 75

90 - 100

120

148

40

840

600

280

QTSE10/90kW-T

238.47

75 - 90

100 - 125

130

170

65

1050

600

320

QTSE10/110kW-T

238.48

90 - 110

125 - 150

155

220

65

1050

600

320

QTSE10/132kW-T

238.49

110 - 132

150 - 180

205

270

70

1250

600

320

CODE

APPROX POWER AT 400V kW

QTSE10/2,2kW-T

238.31

2,2

QTSE10/4kW-T

238.32

4

QTSE10/5,5kW-T

238.33

5,5

QTSE10/7,5kW-T

238.34

7,5

QTSE10/11kW-T

238.35

QTSE10/15kW-T

238.36

QTSE10/18,5kW-T

238.37

QTSE10/22kW-T

238.38

QTSE10/30kW-T

238.39

QTSE10/37kW-T QTSE10/45kW-T

MODEL

APPROX POWER AT 400V Hp

www.manieroelettronica.it

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

31


CONTROL PANELS FOR 2 THREE-PHASE ELECTRIC PUMPS STAR DELTA START WITH THERMAL PROTECTION

QTSE20/...kW-T Electromechanic Star-Delta Control panel for 2 Three-phase electric pumps with Thermal protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electromechanic control panel star-delta start; – Power supply 3~ 50/60Hz 400V±10%; – Very low voltage inputs for external controls from pressure switches or float switches; – Very low voltage inputs for pressure switch or minimum level float switch against dry running or too full; – Cam switches for automatic-off-manual iiiworking; – Contactors with thermal relay internally iiiresetable; – Main pilot light; – N°2 operating motor lights; – N°2 protection motor lights; – Motor protection fuses;

– Auxiliary protection fuses; – General disconnecting switch with door lock; – Star-delta exchange timer adjustable from 0 to 30”; – Metal box; – Protected to IP 55. N.B.: For emptying use with 3 bulb float switches (n.1 of stop and n.2 of run) contact our technical sales office.

DESIGNED FOR FITTING OF: – SU2/24V code 251.72 (see last pages): IIIexchanger on undecal base for 2 electric IIIpumps, plus undecal base wired ZUC/SU2 IIIcode 225.22 (see last pages) it always must be IIIbound together to the exchanger.

For the addition of VOLTMETER/AMMETER KIT, contact our technical/sales office (see last pages).

OPERATING CONDITIONS: – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

kW

Hp

MIN

MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTSE20/2,2kW-T

239.51

2,2

3

5

5,5

24

740

500

230

QTSE20/4kW-T

239.52

4

5,5

7,8

9

24

740

500

230

QTSE20/5,5kW-T

239.53

5,5

7,5

10

14

24

740

500

230

QTSE20/7,5kW-T

239.54

7,5

10

15

18

26

740

500

235

QTSE20/11kW-T

239.55

11

15

18

23

26

740

500

235

QTSE20/15kW-T

239.56

15

20

24

35

32

740

500

235

QTSE20/18,5kW-T

239.57

18,5

25

35

45

40

850

600

260

QTSE20/22kW-T

239.58

18,5 - 22

25 - 30

35

52

40

850

600

260

QTSE20/30kW-T

239.59

30

40

49

66

70

1050

600

320

QTSE20/37kW-T

239.60

37

50

75

85

80

1050

800

320

QTSE20/45kW-T

239.61

45

60

80

98

85

1050

800

320

For QTSE20/ from 55kW to 132kW contact our technical/sales office

32

www.manieroelettronica.it


CONTROL PANELS FOR 3 THREE-PHASE ELECTRIC PUMPS STAR DELTA START WITH THERMAL PROTECTION

QTSE30/...kW-T Electromechanic Star-Delta Control panel for 3 Three-phase electric pumps with Thermal protection

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electromechanic control panel star-delta start; – Power supply 3~ 50/60Hz 400V±10%; – Very low voltage inputs for external controls from pressure switches or float switches; – Very low voltage inputs for pressure switch or minimum level float switch against dry running or too full; – Cam switches for automatic-off-manual working; – Contactors with thermal relay internally resetable; – Main pilot light; – N°3 operating motor lights; – N°3 protection motor lights; – Motors protection fuses;

DESIGNED FOR FITTING OF:

– Auxiliary protection fuses; – General disconnecting switch with door lock; – Star-delta exchange timer adjustable from 0 to 30”; – Metal box; – Protected to IP 55.

– SG4/230-400V code 251.77 (see last pages): Sequential exchanger for 3 electric pumps, wired on the control panels. For the addition of VOLTMETER/AMMETER KIT, contact our technical/sales office (see last pages).

N.B.: For emptying use with 4 bulb float switches (n.1 of stop and n.3 of run) contact our technical sales office.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 400V

APPROX POWER AT 400V

CURRENT ABSORPTION (A)

CURRENT ABSORPTION (A)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

(FOR EACH MOTOR)

kW

Hp

MIN

MAX

2,2

3

5

5,5

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

51

850

600

235

QTSE30/2,2kW-T

240.11

QTSE30/4kW-T

240.12

4

5,5

7,8

9

51

850

600

235

QTSE30/5,5kW-T

240.13

5,5

7,5

10

14

51

850

600

235

QTSE30/7,5kW-T

240.14

7,5

10

15

18

51

850

600

235

QTSE30/11kW-T

240.15

11

15

18

23

51

850

600

235

QTSE30/15kW-T

240.16

15

20

24

35

51

850

600

235

QTSE30/18,5kW-T

240.17

18,5

25

35

45

58

1050

800

320

QTSE30/22kW-T

240.18

18,5 - 22

25 - 30

35

52

60

1050

800

320

QTSE30/30kW-T

240.19

30

40

49

66

90

1450

800

460

QTSE30/37kW-T

240.20

37

50

75

85

95

1650

800

560

For QTSE30/ from 45kW to 132kW contact our technical/sales office

www.manieroelettronica.it

33


CONTROL PANELS FOR 1 THREE-PHASE ELECTRIC PUMP REACTANCE START WITH THERMAL PROTECTION

QTRE10/...kW-T Electromechanic reactance control panel for 1 three-phase electric pump with thermal protection

Control panels with reactance start are used to limit the starting power of the motor up to 30% compared to a direct start starting, they are very useful when direct start is not accepted. .

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS:

– Electromechanic reactance start control panel; – Power supply 3 ~ 50/60Hz 400V ± 10%; – Very low voltage input for external control from iiipressure or float switch; – Cam switch for automatic/off/manual working; – Main pilot light; – Motor operating light; – Protected motor light; – Contactors with thermal relay internally resetable; – Motor protection fuses; – Auxiliary protection fuses; – General disconnecting switch with door lock; – Timed reactance start adjustable from 0 to 30”; – Metal box; – Protected to IP 55.

DESIGNED FOR FITTING OF:

OPERATING CONDITIONS:

– CLU2/3S-24V code 632.311 (see last pages): undecal base level control with 3 electrodes, plus undecal base wired ZUC/ CLU-3S code 225.23 (see last pages) it IIImust be always bound together to the level control.

– Acceleration time 15 seconds max.; – Starting/hour frequency: a maximum of 4 of which not more than 2 consecutively; – The calibration of the timer needs be to set in relation to the electric pump (0- 15 sec.); – Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

ADDITIONAL VOLTMETER AND AMMETER KIT: K-V-A/2,2-5,5kW code 225.82 for models for 4 and 5,5kW; K-V-A/7-10kW code 225.83 for models of 7,5 kW; K-V-A/11-22kW code 225.84 for models from 11 to 22 kW; K-V-A/30-55kW code 225.85 for models from 30 to 55 kW; K-V-A/59-75kW code 225.86 for models from 66 and 75 kW; K-V-A/90-150kW code 225.87 for models from 90 to 150 kW; (see last pages).

N.B.: it is possible to supply customized control panels with reduced impedance based on the exact cheracteristics of the electricpump in use, in this case the price of the control panel will be lower. Contact our technical/sales department for details.

TECHNICAL DATA AND OPERATING POWERS MODEL

34

CODE

APPROX POWER AT 400V kW

APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTRE10/4kW-T

241.01

4

5,5

9

11

19

550

400

230

QTRE10/5,5kW-T

241.02

5,5

7,5

13

14,5

19

550

400

230

QTRE10/7,5kW-T

241.03

7,5

10

14

21

21

550

400

230

QTRE10/11kW-T

241.04

11

15

20

29

22

550

400

230

QTRE10/15kW-T

241.05

15

20

28

35

36

750

500

235

QTRE10/18,5kW-T

241.06

18,5

25

35

45

36

750

500

235

QTRE10/22kW-T

241.07

22

30

46

58

41

750

500

235

QTRE10/30kW-T

241.08

30

40

60

68

41

750

500

235

QTRE10/37kW-T

241.09

37

50

70

86

52

750

500

260

QTRE10/45kW-T

241.10

45

60

85

100

78

850

600

310

QTRE10/55kW-T

241.12

55

75

105

130

78

850

600

310

QTRE10/66kW-T

241.14

66

90

120

145

114

1050

800

360

QTRE10/75kW-T

241.15

75

100

120

162

120

1050

800

360

QTRE10/90kW-T

241.16

90

125

150

200

120

1250

800

460

QTRE10/110kW-T

241.17

110

150

180

240

140

1250

800

460

QTRE10/132kW-T

241.18

132

180

220

285

150

1250

1000

460

www.manieroelettronica.it


SOFT-START CONTROL PANELS FOR 1 THREE-PHASE ELECTRIC PUMP WITH THERMAL PROTECTION

QTSS10/...kW-T Three-Phase Soft-Start Control Panel for 1 electric pump with thermal protection

After star-delta and reactance starting, we propose the soft-start control panels with static converters, which are especially suitable for the starting of electric pumps for which is necessary to avoid acceleration and/or deceleration jolting. Acceleration and deceleration times can be adjusted independently as required; after the starting phase has terminated, the motor is connected to the line.

CONNECTION DIAGRAM

A

P

B

GENERAL CHARACTERISTICS: For the addition of VOLTMETER/AMMETER KIT, contact our technical/sales office (see last pages).

– Control panel with electronic components; – Power supply input 3 ~ 50/60Hz 400V ± 10%; – Very low voltage inputs for external control from pressure switch or float switch; – Very low voltage input for external control by float or pressure switch for “minimum level control”; – Selector for automatic-off-manual operation; – Adjusters: a) initial voltage; b) acceleration time; c) deceleration time; – Main pilot light; – Operating motor light; – Protected motor light; – Soft-starter with internal by-pass; – Contactor with thermal relay internally resetable; – Motor protection fuses; – Auxiliary circuits protection fuses; – General disconnecting switch with door lock; – Metal box; – Protected to IP 55.

N.B.: For emptying use with 2 bulb float switches (n.1 of stop and n.1 of run) contact our technical sales office.

OPERATING CONDITIONS:

N.B.: For loads with a strong starting inertia (e.g.: fans, compressors, pumps, mills, crushers, etc.) contact our technical/ sales office.

– Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

N.B.: In order to select the correct model make sure the electrical input of the motor in Amp is included in the two operating power values of the panel.

TECHNICAL DATA AND OPERATING POWERS APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A)MIN

2,2

3

4,5

6

17

550

400

230

4

5,5

6

9

19

550

400

230

242.32

5,5

7,5

9

12

19

550

400

230

242.33

7,5

10

14

18

21

550

400

230

QTSS10/11kW-T

242.34

11

15

17

22

22

550

400

230

QTSS10/15kW-T

242.35

15

20

26

32

36

550

400

230

QTSS10/18,5kW-T

242.36

18,5

25

28

36

36

750

500

235

QTSS10/22kW-T

242.37

18,5 - 22

25 - 30

35

44

41

750

500

235

QTSS10/30kW-T

242.38

30

40

46

59

41

750

500

235

QTSS10/37kW-T

242.39

37

50

60

72

52

750

500

235

QTSS10/45kW-T

242.40

45

60

70

85

65

850

600

280

CODE

APPROX POWER AT 400V kW

QTSS10/2,2kW-T

242.30

QTSS10/4kW-T

242.31

QTSS10/5,5kW-T QTSS10/7,5kW-T

MODEL

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

For QTSS10/ from 55kW to 132kW contact our technical/sales office

www.manieroelettronica.it

35


INTELLIGENT DRY CHECK MICROPROCESSOR-BASED CONTROL PANELS FOR DRY RUN PROTECTION

Maniero Elettronica, continuing its policy of launching state-of-the-art products, has now incorporated microprocessor controlled systems (intelligent) into its standard boards for protecting and controlling motors and electric pumps.

DRY CHECK Second generation ...easier to calibrate, more flexible, a greater variety of functions available.

These versatile systems can be personalised at any time as they are fitted with programmable software that can be changed to satisfy just one single requirement. The DRY CHECK function is a special feature of this new series of intelligent control panels that concentrate in a single control panel not just an extremely attractive price but also all the controls and protections that installers would normally require for their customers’ pumps. Controls and protections are clearly illustrated in the general characteristics. On the DRY CHECK series probes are not required as this control is carried out by measuring the cos  (power factor) absorbed by the motor. – QMD10/...kW-A-CMS2 Single-phase Direct Start Control Panel page 38 – QTD10/...kW-A-CMS2 Three-phase Direct Start Control Panel page 39 – QTS10/...kW-A-CMS Star-delta Start Control Panel page 40 – QTR10/...kW-A-CMS Three-phase Reactance Start Control Panel page 41

GENERAL CHARACTERISTICS OF ALL “DRY CHECK” SERIES CONTROL PANELS: – Electronic microprocessor panel; – Very low voltage input for external control from pressure switch or float switch; – Mains indicator and over-voltage or under-voltage alarm LED; – Automatic-off-manual operating LED; – Motor running LED; – Dry running and/or min/max level alarm LED; – Overload protection or out of order C.T. activated Led; – Automatic/off/manual operating Led; – Push button to select the automatic-off-manual functioning modes and to reset alarm conditions (OPTIONAL: automatic/off/manual operating on selector); – Protection against phase failure or C.T. damage, with alarm visualisation displayed in case of intervention; – 4 second delay in the triggering of the protection against phase failure or C.T. damage; – Phase overload protection with power micro

36

switches (dipswitch) and visual alarm display in the event of its triggering; – 4 second triggering delay of the overload protection; – Protection against mains over-voltage and under-voltage (excludable), power voltage is regulated by micro switches; – One minute delay before the triggering and re-setting of the overvoltage and undervoltage protection; – Protection against dry running based on a cos  power factor (COS-FI) with micro switch cos  from 0,15 to 0,9 and protection deactivation switch; – Delayed operation of dry running protection with microswitches with settings of 1s, 5s, 10s, 20s; – Selectable additional 5 second delay before the triggering of the dry running protection; – Micro switches for activating the external alarm in the event of the dry running alarm

www.manieroelettronica.it

triggering (OPTIONAL); – Micro switches for activating the external alarm in the event of the min/max level alarm triggering (OPTIONAL); – Automatic reset of dry start-up protection device with 4 attempts in 90’ (after 5 /20/40/90 minutes), with enable selector; – Automatic resetting of the dry running protection with further attempts after the previous 4, with activating switch and micro switches for the enable and resetting interval regulating 1h, 2h,4h, 8h; – Motor protection fuses; – Auxiliary circuits protection fuses; – General disconnecting switch with door-lock; – Control panel protected to IP55.


DRY-CHECK CONTROL PANELS

"We feel positive, look at our results"

www.manieroelettronica.it

37


INTELLIGENT DRY CHECK SINGLE-PHASE CONTROL PANELS

QMD10/...kW-A-CMS2 Single-Phase Direct Start Control Panel for 1 Electric Pump with Ammetric Protection and Dry Check Protection (cos)

P

COM

START

A

RUN

CONNECTION DIAGRAM

B

SPECIFIC CHARACTERISTICS: DESIGNED FOR FITTING OF: for general characteristics see page 36 – Power supply 1~ 50/60Hz 230...240Vca ±10%; – Threshold voltage for alarms regulated via micro switches (dipswitch): a) 230V-11% from to 240V+11% b) 240V ±11% c) 230V ±11% d) 220V ±11% – Very low voltage input for external control from pressure switch or float switch of min/max level; – Thermoplastic box.

ELECTRONIC SPARE PARTS:

– MA/1-100mm, code 221.23 (see last pages) external alarm command module for dry running or floats triggering min/max; – KCC/...: wired capacitor kit (depending on the chosen motor see last pages); – MIC/1E-..V-2U in 3 versions (see last pages): interface module for control from an external device with 12V~ or 24V~ voltage or 230V~ dry contacts output.

– Mother board, Code 219.59; – Synoptic, Code 224.99.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS

38

MODEL

CODE

APPROX POWER AT 230V kW

APPROX POWER AT 230V Hp

CURRENT ABSORPTION (A)MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QMD10/2,2kW-A-CMS2

234.32

0,37 - 2,2

0,5 - 3

0,8

18

1,8

265

200

130

www.manieroelettronica.it


INTELLIGENT DRY CHECK THREE-PHASE DIRECT START CONTROL PANELS

QTD10/...kW-A-CMS2 Three-Phase Direct Start Control Panel for 1 Electric Pump with Ammetric Protection and Dry Check Protection (cos)

CONNECTION DIAGRAM

A

P

B

SPECIFIC CHARACTERISTICS:

for general characteristics see page 36 – Control panel direct start; – Power supply 3~50/60Hz 400...415Vca ±10%; – Threshold voltage for alarms regulated via micro switches (dipswitch): a) 400V-11% from to 415V+11% b) 415V ±11% c) 400V ±11% d) 380V ±11% – Very low voltage input for external control from pressure switch or float switch of min/max level; – Thermoplastic box.

DESIGNED FOR FITTING OF:

ELECTRONIC SPARE PARTS:

– MA/1-100mm, code 221.23 (see last pages) IIIexternal alarm command module IIIfor dry running or floats triggering min/max; – MIC/1E-..V-2U in 3 versions (see last pages): interface module for control from an external device with 12V~ or 24V~ voltage or 230V~ dry IIIcontacts output.

– Mother board for models till 7kW IIICode 219.60; – Mother board for models from 10kW to III16kW Code 219.61; – Synoptic Code 224.99.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS CURRENT ABSORPTION (A) MAX

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

CODE

APPROX POWER AT 400V kW

APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A)MIN

QTD10/3,7kW-A-CMS2

236.21

0,37 - 3,7

0,5 - 5

0,8

8

1,8

265

200

130

QTD10/5kW-A-CMS2

236.22

0,37 - 5

0,5 - 7

0,8

11

1,9

265

200

130

QTD10/7kW-A-CMS2

236.23

0,37 - 7

0,5 - 9,5

0,8

16

2,7

315

240

160

QTD10/10kW-A-CMS2

236.24

0,75 - 10

1 - 14

1,5

22

2,8

315

240

160

QTD10/13,5kW-A-CMS2

236.25

0,75 - 13,5

1 - 18

1,5

29

2,8

315

240

160

QTD10/16kW-A-CMS2

236.26

0,75 - 16

1 - 22

1,5

34

4

430

315

165

MODEL

www.manieroelettronica.it

WEIGHT kg

39


INTELLIGENT DRY CHECK THREE-PHASE STAR-DELTA START CONTROL PANEL FOR 1 ELECTRIC PUMP

QTS10/...kW-A-CMS Star-delta start control panel for 1 three-phase electric pump with overload current protection and Dry Check (cos)

CONNECTION DIAGRAM

A

B

P

SPECIFIC CHARACTERISTICS:

DESIGNED ESIGNED FOR FITTING OF:

for general characteristics see page 36 – Star-delta start control panel; – Power supply 3~50/60Hz 400...415Vca ±10%; – Threshold voltage for alarms regulated via micro switches (dipswitch): a) 400V-11% up to 415V+11% b) 415V ±11% c) 400V ±11% d) 380V ±11% – 15s control switchover protection on start up; – Metal box.

– MA/1-100mm, code 221.23 (see last pages) external alarm command module for dry running or floats triggering min/max; – MIC/1E-..V-2U in 3 versions (see last pages): interface module for control from an external device with 12V~ or 24V~ voltage or 230V~ dry contacts output.

ELECTRONIC SPARE PARTS: – Mother board: given that there are different power values for these electronic spare-parts check the Ampere value on the printed circuit board, marked under the word “SIZE” and inform our technical/sales office; – Synoptic Code 224.99. OPERATING CONDITIONS: – Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 400V kW

APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A)MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTS10/4kW-A-CMS

238.62

1,1 - 4

1,5 - 5,5

3,6

9

16

550

400

230

QTS10/5,5kW-A-CMS

238.63

1,1 - 5,5

1,5 - 7,5

3,6

14

16

550

400

230

QTS10/7,5kW-A-CMS

238.64

1,1 - 7,5

1,5 - 10

3,6

18

16

550

400

230

QTS10/11kW-A-CMS

238.65

1,1 - 11

1,5 - 15

3,6

23

16

550

400

230

QTS10/15kW-A-CMS

238.66

1,1 - 15

1,5 - 20

3,6

35

16

550

400

230

QTS10/18,5kW-A-CMS

238.67

1,5 - 18,5

2 - 25

5

45

20

740

500

260

QTS10/22kW-A-CMS

238.68

1,5 - 22

2 - 30

5

52

20

740

500

260

QTS10/30kW-A-CMS

238.69

2,2 - 30

3 - 40

10

66

25

740

500

260

QTS10/37kW-A-CMS

238.70

2,2 - 37

3 - 50

10

85

35

740

500

260

QTS10/45kW-A-CMS

238.71

2,2 - 45

3 - 60

10

98

40

840

600

280

QTS10/55kW-A-CMS

238.73

5 - 55

6,5 - 70

20

125

45

840

600

280

QTS10/75kW-A-CMS

238.76

5 - 75

6,5 - 100

20

148

60

1050

600

320

QTS10/90kW-A-CMS

238.77

5 - 90

6,5 - 125

20

170

65

1050

800

320

QTS10/110kW-A-CMS

238.78

7 - 110

9,5 - 150

40

220

65

1050

800

320

QTS10/132kW-A-CMS

238.79

7 - 132

9,5 - 180

40

270

70

1250

600

420

NOTES: the value of the power rating is indicative, for a correct choice of the model, pls-check that motor ampere absorption is within thermal protection value. For possible variations to normal system, please contact our technical/sales office. MANIERO ELETTRONICA reserves the right to improve its products without prior notice. The addition of modules can lead to variations in the size of the box and the overall cost of the control panel.

40

www.manieroelettronica.it


INTELLIGENT DRY CHECK THREE-PHASE REACTANCE START CONTROL PANEL FOR 1 ELECTRIC PUMP

QTR10/...kW-A-CMS Three-Phase Reactance Start Control Panel for 1 Electric Pump with overload current protection and Dry Check Protection (cos)

CONNECTION DIAGRAM

A

P

B

SPECIFIC CHARACTERISTICS: DESIGNED FOR FITTING OF: for general characteristics see page 36 – Reactance start control panel; – Power supply 3~50/60Hz 400...415Vca ±10%; – Threshold voltage for alarms regulated via micro switches (dipswitch): a) 400V-11% up to 415V+11% b) 415V ±11% c) 400V ±11% d) 380V ±11% – 15s control switchover protection on start up; – Metal box;

ELECTRONIC SPARE PARTS:

– MA/1-100mm, code 221.23 (see last pages) external alarm command module for dry running or floats triggering min/max; – MIC/1E-..V-2U in 3 versions (see last pages): interface module for control from an external device with 12V~ or 24V~ voltage or 230V~ dry contacts output.

– Mother board: given that there are different power values for these electronic spare-parts check the Ampere value on the printed circuit board, marked under the word “SIZE” and inform our technical/sales office; – Synoptic Code224.99.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

APPROX POWER AT 400V kW

APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A) MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTR10/4kW-A-CMS

240.82

1,1 - 4

1,5 - 5,5

3,6

11

19

550

400

230

QTR10/5,5kW-A-CMS

240.83

1,1 - 5,5

1,5 - 7,5

3,6

14,5

19

550

400

230

QTR10/7,5kW-A-CMS

240.84

1,1 - 7,5

1,5 - 10

3,6

21

21

550

400

230

QTR10/11kW-A-CMS

240.85

1,1 - 11

1,5 - 15

3,6

29

22

550

400

230

QTR10/15kW-A-CMS

240.86

1,1 - 15

1,5 - 20

3,6

35

36

750

500

240

QTR10/18,5kW-A-CMS

240.87

1,5 - 18,5

2 - 25

5

45

36

750

500

240

QTR10/22kW-A-CMS

240.88

1,5 - 22

2 - 30

10

58

41

750

500

240

QTR10/30kW-A-CMS

240.89

2,2 - 30

3 - 40

10

68

41

750

500

240

QTR10/37kW-A-CMS

240.90

2,2 - 37

3 - 50

10

86

52

750

500

260

QTR10/45kW-A-CMS

240.91

2,2 - 45

3 - 60

10

100

78

850

600

310

QTR10/55kW-A-CMS

240.92

5 - 55

6,5 - 75

20

130

78

850

600

310

QTR10/66kW-A-CMS

240.93

5 - 66

6,5 - 90

20

145

114

1050

800

360

QTR10/75kW-A-CMS

240.94

5 - 75

6,5 - 100

20

162

120

1050

800

360 460

QTR10/90kW-A-CMS

240.95

9 - 90

9,5 - 125

20

200

120

1250

800

QTR10/110kW-A-CMS

240.96

7 - 110

9,5 - 150

40

240

140

1250

800

460

QTR10/132kW-A-CMS

240.97

7 - 132

9,5 - 180

40

285

150

150

1000

460

www.manieroelettronica.it

41


THREEPHASE FIRE FIGHTING CONTROL PANELS UNI EN 12845

42

www.manieroelettronica.it


UNI EN 12845 FIRE FIGHTING SYSTEM CONTROL PANELS

The new series of fire fighting control panels is in compliance with UNI EN 12845. We offer as standard production a full range of panels for electric pumps till 132kW featuring several type of starters, as well as service panels and alarm systems.

OUR PRODUCTS Our UNI 12845-compliant direct, star-delta and reactance start control panels are built in conformity with general EEC standards and they have the following technical features: • power or phase failure detection alarm systems; alarm system for signalisation of phase sequence error • all signal lamps are LEDs for signalling of: - phase presence of input power supply - phase presence of motor power supply - start request - pump running - starting failure • dry contacts outputs for signalling of: - power supply not available - start request pump running - starting failure • key-operated selector for Automatic – Off - Manual modes; • start and stop buttons and panel status signal lamps. • input for 2 pressure switches for pump control; • input for priming float switch • input for “pump running” signal pressure switch; • ammeter; • voltmeter with selector for phase voltage monitoring.

ADDITIONAL FUNCTIONS AND FEATURES Our panels also include other features as standard which, although not required by UNI12845, are often extremely important and useful to complete a fire-fighting system: • Phase failure signalling • All the outputs are available as switch contacts, but three of them also supply a signal when the relay is idle (“Power alarm” “Start request” and “start failure” ), and the fourth function likewise when the relay is energised (“Pump running”). • If used appropriately, the outputs also signal failures in the connection between the main panel and the signalling system in the unit monitored. • Timer for automatic stop of the electric pump for the application in the systems regulated by UNI 10779:2007 (appendix A) relative to the fuel pumps in the hydrant network: “Fuel pumps in a hydrant network must have automatic start and manual stop features, as envisaged by UNI 12845. Wherever deemed necessary, for all activity which is not constantly monitored, the automatic stop feature is permitted as long as the pump system is used solely by thehydrant network. In this case, the unit can stop automatically when the pressure has been maintained above pump start-up pressure constantly for at least 20 minutes ”. This function is featured as standard and is activated by microselector.

www.manieroelettronica.it

43


THREE-PHASE SERVICE PANELS FOR FIRE-FIGHTING SYSTEMS

QTDAS10/...kW-A-2 Fire prevention service direct start Control panel for 1 Three-phase compensation pump with Ammetric protection and Preset Mother Board

Service panels are not required by UNI EN 12845 but they are useful and sometimes even essential for the makeup pump’s operation and to house all those accessories which, although not envisaged by the standard, are often useful in a fire-fighting system.

CONNECTION DIAGRAM

CONNECTION DIAGRAM A

N.C. INPUTS N.C. OUTPUT OUTPUT PUMP ALARM CONTACTS FOR SIREN WORKING

P

POWER SUPPLY INPUT 3~ 50/60Hz 400V ±10%

FLOAT OR PRESSURE SWITCHES

B

MOTOR

GENERAL CHARACTERISTICS:

– Control panel with electronic components; – Power supply 3~ 50/60Hz 230/400V ±10%; – Very low voltage input for external control from pressure or float switch; – Very low voltage inputs for external control by float or pressure switch for minimum level control against dry running or too much full; – Selector for pressure switch or minimum level float (contacts NC or NO); – Main pilot light; – Operating motor light; – Protected motor light; – Min/Max water level alarm light; – Selector for automatic-of-manual operation (the last control is not latched); – Electronic protection with adjustable current and cut-in time; – External push-button for ammetric protection reset; – Motor protection fuses; – Auxiliary circuits protection fuses; – General disconnecting switch with door lock;

– Metal box; – Protected to IP 55.

ELECTRONIC SPARE PARTS: – Mother board Code 223.62; – Synoptic Code 316.03.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

DESIGNED FOR FITTING OF: – MCL/3S-300 code 221.05 level control module for 3 level sensors or 2 floats (filling or emptying); – MCL/2ST-300 code 221.04 level control module for 2 timed level sensor (filling or emptying); N.B.: the modules MCL/3S and MCL/2ST have the function to replace the pressure switch or the minimun level float.

TECHNICAL DATA AND OPERATING POWERS

44

APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A)MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

0,55 - 3,7

0,75 - 5

0,55 - 5

0,75 - 7

2

8

15

450

300

165

2

11

15

450

300

246.13

0,55 - 7

165

0,75 - 9,5

2

16

15

450

300

QTDAS10/10kW-A-2

246.14

165

7,5 - 10

10 - 14

16

22

16

450

300

165

QTDAS10/13,5kW-A-2

246.15

7,5 - 13,5

10 - 18

16

29

16

450

300

165

MODEL

CODE

APPROX POWER AT 400V kW

QTDAS10/3,7kW-A-2

246.11

QTDAS10/5kW-A-2

246.12

QTDAS10/7kW-A-2

www.manieroelettronica.it


UNI EN 12845 FIRE PREVENTION DIRECT START CONTROL PANEL

QTDA10/...kW-F-3 UNI EN 12845 rules fire prevention direct start control panel for 1 surpress pump with fuses protection

CONNECTION DIAGRAM CONNECTION DIAGRAM

A START UP FAILURE

PRIMING PRESSURE FLOAT SWITCH SWITCH PUMP WORKING

SL/SP 1

SL/SP 2

POWER SUPPLY NOT AVAILABLE

OUTPUT CONTACTS CALL FOR START

OUTPUT CONTACTS PUMP WORKING

POWER SUPPLY INPUT 3N~ 50/60Hz 400V ±10%

FLOAT OR PRESSURE SWITCHES MOTOR

P

B

GENERAL CHARACTERISTICS:

– Electronic control panel with microprocessor control module; – Power supply 3N~ 50/60Hz 400V ± 10%; – n. 4 Very low voltage inputs for external control from pressure switches and float switches; - No. 4 relay outputs 1 switch contact N.O. / N.C. (contact capacity max. 250V~ 3A resistive or weakly inductive load) for signalling: • Pump running; • Pump start-up request; • No power; • Pump start-up failure; - Key-operated selector for “manual / Off / automatic” operation - No. 2 pushbuttons for motor “start” and “stop” and “lamp test”; - No. 11 indicator lights with LED for display: • input power phases (power presence and

phases sequence); • motor power output phases (power presence); • Pump start-up request; • Pump running; • Pump start-up failure; • Status of “Start” pushbutton; • Status of “stop” pushbutton; - Phases sequence error protection; - Motor protection fuses; - Auxiliary circuit protection fuses ; - Ammeter; - Voltmeter with voltage selector; - General disconnecting switch with door lock; - Metal box; - Protected to IP55. N.B.: Start and stop buttons and all signalling leds are protected by a IP55 membrane.

ACCESSORIES NECESSARY FOR UNI EN 12845 FIRE PREVENTION RULES: – SAL/6I, code 252.28: self powered 24h acoustic and visual siren.

ELECTRONIC SPARE PARTS: – Control level module, Code 250.13; – Synoptic, Code 316.16. OPERATING CONDITIONS: – Ambient temperature -5/+40°C; – Relative moisture 50% with a max temperature of 40°C.

ION VERS W E N

TECHNICAL DATA AND OPERATING POWERS CURRENT ABSORPTION (A)MIN

CURRENT ABSORPTION (A) MAX

DIMENSIONS mm A

0,5 - 2

1

4,5

14,5

550

400

230

3-7

4,2

11

14,5

550

400

230

DIMENSIONS mm B

DIMENSIONS mm P

CODE

APPROX POWER AT 400V kW

APPROX POWER AT 400V Hp

QTDA10/1,5kW-F-3

246.80

0,37 - 1,5

QTDA10/5kW-F-3

246.81

2,2 - 5

QTDA10/7kW-F-3

246.82

4-7

5,5 - 9,5

8,5

18

14,5

550

400

230

QTDA10/10kW-F-3

246.83

4 - 10

5,5 - 14

8,5

22

15,5

550

400

230

QTDA10/13,5kW-F-3

246.84

4 - 13,5

5,5 - 18

8,5

29

15,5

550

400

230

QTDA10/16kW-F-3

246.85

11 - 16

15 - 22

22

35

16,5

550

400

230

QTDA10/18,5kW-F-3

246.86

11 - 18,5

15 - 25

22

45

18

650

400

230

QTDA10/22kW-F-3

246.87

11 - 22

15 - 30

22

56

18

650

400

230

MODEL

www.manieroelettronica.it

WEIGHT kg

45


UNI EN 12845 FIRE PREVENTION STAR DELTA START CONTROL PANEL

QTSA10/...kW-F-3 UNI EN 12845 rules fire prevention star-delta start control panel for 1 surpress pump with fuses protection

CONNECTION DIAGRAM CONNECTION DIAGRAM

A START UP FAILURE

PRIMING FLOAT SWITCH

PRESSURE SWITCH PUMP WORKING

SL/SP 1

SL/SP 2

POWER SUPPLY NOT AVAILABLE

OUTPUT CONTACTS CALL FOR START

OUTPUT CONTACTS PUMP WORKING

POWER SUPPLY INPUT 3N~ 50/60Hz 400V ±10%

FLOAT OR PRESSURE SWITCHES

P

MOTOR

B

GENERAL CHARACTERISTICS:

– Electronic control panel with microprocessor control module; – Power supply 3N~ 50/60Hz 400V ± 10%; – No. 4 Very low voltage inputs for external control from pressure switches and float switches; No. 4 relay outputs 1 switch contact N.O. / N.C. (contact capacity max. 250V~ 3A resistive or weakly inductive load) for signalling: • Pump running; • Pump start-up request; • No power; • Pump start-up failure; - Key-operated selector for “manual / Off / automatic” operation; - No. 2 pushbuttons for motor “start” and “stop” and “lamp test”; - Star delta exchange timer - No. 11 indicator lights with LED for display:

• Input power phases (power presence and phases sequence); • Motor power output phases (power presence); • Pump start-up request; • Pump running; • Pump start-up failure; • Status of “Start” pushbutton; • Status of “stop” pushbutton; - Phases sequence error protection; - Motor protection fuses; - Auxiliary circuit protection fuses ; - Ammeter; - Voltmeter with voltage selector; - General disconnecting switch with door lock; - Metal box; - Protected to IP55. N.B.: Start and stop buttons and all signalling leds are protected by a IP55 membrane.

ACCESSORIES NECESSARY FOR UNI EN 12845 FIRE PREVENTION RULES: – SAL/6I, code 252.28: self powered 24h acoustic and visual siren.

ELECTRONIC SPARE PARTS: – Control module, Code 250.13; – Synoptic, Code 316.16.

OPERATING CONDITIONS: – Ambient temperature -5/+40°C; – Relative moisture 50% with a max IIItemperature of 40°C.

N ERSIO V W NE TECHNICAL DATA AND OPERATING POWERS CODE

APPROX POWER AT 400V kW

APPROX POWER AT 400V Hp

CURRENT ABSORPTION (A)MIN

CURRENT ABSORPTION (A) MAX

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

QTSA10/5,5kW-F-3

247.00

2,2 - 5,5

3 - 7,5

4

14

23

640

400

230

QTSA10/7,5kW-F-3

247.01

4 - 7,5

5,5 - 10

8

18

23

640

400

230

QTSA10/11kW-F-3

247.02

4 - 11

5,5 - 15

8

23

23

640

400

230

QTSA10/15kW-F-3

247.03

4 - 15

5,5 - 20

8

35

30

640

400

230

QTSA10/18,5kW-F-3

247.04

11 - 18,5

15 - 25

18

45

30

640

400

230

QTSA10/22kW-F-3

247.05

11 - 22

15 - 30

18

52

32

740

500

230

QTSA10/30kW-F-3

247.06

22 - 30

30 - 40

35

66

34

740

500

230

QTSA10/37kW-F-3

247.07

22 - 37

30 - 50

35

85

40

740

500

230

QTSA10/45kW-F-3

247.08

22 - 45

30 - 60

35

98

45

840

600

310

QTSA10/55kW-F-3

247.09

22 - 55

30 - 75

35

125

52

840

600

310

QTSA10/75kW-F-3

247.10

45 - 75

60 - 100

80

148

65

1050

600

360

QTSA10/90kW-F-3

247.11

75 - 90

100 - 125

120

170

70

1050

600

360

QTSA10/110kW-F-3

247.12

75 - 110

100 - 150

120

220

75

1050

800

360

QTSA10/132kW-F-3

247.13

75 - 132

100 - 180

120

270

80

1050

800

360

MODEL

46

www.manieroelettronica.it


QMA/1230-U12V-3

SINGLE PHASE CONTROL PANELS FOR MOTORISED PUMPS

ION VERS W E N

A

Maniero Elettronica offers tailor-made solutions on panels for motorised pumps to meet your specific requirements. Contact our technical-sales office for all relevant information

B

P GENERAL CHARACTERISTICS:

- Panel with microprocessor control module for start-up of a motorised pump with diesel engine; - Power supply 1N~50/60Hz 230V±10% for battery charging; - Power supply for motor start-up from two external batteries; - 2 battery chargers; - Inputs for control pressure switches and priming tank float; - Inputs for motor status detection sensors; - Outputs for motor start-up and shutdown; - Output for heater; - 5 relay outputs for alarm signal: • automatic mode excluded; • start-up failure; • Pump running; • Control panel fault; • Low fuel level; - Key switch for automatic start-up block; 2 emergency start-up pushbuttons under breakable cover; Microprocessor control unit for management of electrical panel with: - Led display, to show: • Battery voltage (2 volt meters); • Battery current (2 ammeters); • Motor rev counter; • Total and partial working hour counter;

• Total and partial working hour counter; • Start-up counter for the two batteries; • Fuel level; • Water and oil temperature; • Oil pressure; - Pushbuttons for control of: • Shutdown; • Manual start-up; • Test; • Commissioning; • Alarm reset; - Microswitches for programming of: • Times for duration and pauses of start-ups and other control parameters; • Language (Italian, English, French, Spanish, German); • Automatic shutdown function according to the standard UNI 10779; Auxiliary circuit protection fuses; General disconnect switch with door lock; Metal housing. OPERATING CONDITIONS: - Ambient temperature -5/+40°C; - Relative humidity 50% with maximum temperature +40°C;

TECHNICAL SPECIFICATIONS AND OPERATING POWER WEIGHT

APPLICABLE BATTERY * MODEL

Qty

QMA/I230-U12V-3

DIMENSIONS mm

CODE

242.94

2

V

Ah

kg

A

B

P

12

100

15

550

400

240

* Battery not supplied as standard

www.manieroelettronica.it

47


ACOUSTIC AND VISUAL WARNING SIGNALS FOR ALARM SYSTEMS IN COMPLIANCE WITH STANDARD UNI EN 12845

“..the entire team here at Maniero is proud to be involved in the success of the company..”

CONNECTION DIAGRAM POWER SUPPLY INPUT

CONTACT OUTPUTS

DIGITAL INPUTS

A 230

0

400

C

NO

NC

ALARM

C

NO

NC

C

IN1

IN2

C

NO

NC

IN3

IN4

IN5

IN6

M

POWER SUPPLY

AUXILIARY OUTPUTS

P

B

GENERAL CHARACTERISTICS:

- Acoustic and visual electronic signal; - AC power supply: 2~ 50/60Hz 24V / 220-240V / 380-415 ± 10%; - DC power supply; 11,5-30Vdc; - Power supply from internal sealed buffer battery Pb 6V; - Acoustic warning signal 82dB(A)1m; - Flashing led indicator (on some models only); - Modular configuration in groups of 6 low voltage contact iiiiinputs: • 1 voltage 12-24Vac / 9-30Vdc / 220-240Vac or NC/NO type iiiiIIcontact; • 3 NC/NO contact type configurable individually via iiii IIIIIImicroswitch; • 1 NC contact type; • 1 NO contact type; - 1 low voltage NO contact type input for temporary or iiiipermanent shutoff of the acoustic signal; - 3 contact outputs with NO / NC changeover (max. contact iiiicapacity 250V~ 5A resistive load) for alarm signal, external iiiipower supply presence, IN6 input closed;

48

- Commands and signals for each module: • Synoptic panel under membrane; • 2 pushbuttons for manual reset from alarm and lights and outputs test/ iiiiIIacoustic signal shutoff; • 10 display leds; Power present, buffer battery level, input status, alarm, iiiiIIacoustic signal shut off; - Communication port with RS485 MODBUS-RTU serial line for slave connection, iiiimaximum connection distance iiii500m, speed 300 / 9600 / 19200 / 38400 bit/s. - Operation setting microswitches: • NC/NO polarity selection of 4 alarm contact inputs; • Alarm duration unlimited / 5 / 30 / 60 minutes; • Ring type continuous / intermittent (30s on - 30s off); • Reset automatic / manual; - Communication setting microswitches: • Termination resistance activation; • Speed, master / slave operation (for Local communication only); • Node address; - Thermoplastic casing; - IP55 protection rating;

www.manieroelettronica.it

C


SALB/6I SA/6I SAL/6I SAL/12I SAL/18I

The range SA.../...I includes various models according to the number of inputs and the presence of a visual flashing signal. All products in the range are modular: this enables customisation of the system according to specific requirements, with up to 8 connected modules

W NE CTS DU RO

P

TECHNICAL SPECIFICATIONS AND OPERATING POWER MODEL

SALB/6I SA/6I SAL/6I SAL/12I SAL/18I

CODE

252.22 252.27 252.28 252.37 252.38

FLASHING N째 MODULES/ LIGHT N째 INPUTS

LED LED LED LED

1/6 1/6 1/6 2/12 3/18

BATTERY AUTONOMY h in alarm

at reset

8 8 8 4 8

18 18 18 7 18

NOMINAL WEIGHT kg POWER (MAX)

3W 3W 3W 6W 9W

1,5 2 2 3 4

www.manieroelettronica.it

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

190 250 250 375 550

240 250 250 250 350

90 180 180 180 180

NOTES

VERSION ON BOX VERSION WITH ACOUSTIC WARNING ONLY VERSION WITH 6 INPUTS VERSION WITH 12 INPUTS VERSION WITH 18 INPUTS

49


S/...V

SL/...V

Acoustic signalling device

Acoustic and Flashing signalling device

ACOUSTIC AND VISUAL WARNING DEVICES AND ACCESSORIES FOR ALARM SYSTEM

A

P

B

GENERAL CHARACTERISTICS:

OPTIONAL:

• Tests of LEDS and outputs; • Acoustic alarm switching off; • Acoustic signaller with sound pressure 82 iiii IIIIdB (A) 1 M with selector for continuous or IIIIintermittent mode; • Led flashing (only model SL/…V) - Type of sound: continuous or intermittent iiiisound (30s ON – 30X OFF): • Thermoplastic box; • Protected to IP55

- Electronic acoustic and visual signaller - Power supply: • 2~ 50/60Hz 220-240V / 380-415 V±10%; • 2~ 50/60Hz 24 V / 18…30 Vdc; • Very low voltage inputs for alarm contacts NO/ iiii NC - Main Pilot light - Led for alarm – Push button for:

- Contact output settable for signalling the iiialarm or “OK” status or acoustic signaller iiicontrol - Output for external acoustic and visual iiisignalling devices (only version 24V).

TECHNICAL DATA AND OPERATING POWERS CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

S82/24V

253.37

2

0,6

180

120

75

VERSIONE SU BOX

S82/230-400V

253.38

2

0,8

180

120

75

VERSIONE SU BOX

SL82/24V

253.39

2

0,8

180

120

170

VERSIONE SU BOX

SL82/230-400V

253.40

2

1

180

120

170

VERSIONE SU BOX

MODEL

NOTE

Red/yellow flashing light 3W to 230V Red/yellow flashing light 3W to 12 or 24V

LL../10-230V LL../3-12-24V

GENERAL CHARACTERISTICS:

– Electronic flash-lamp; – Power supply 1~50/60Hz ...V±10%: • 12/24V (model LLR/3-12Vcc or 24V and LLG/3-12Vcc or 24V); • 230V~ (model LLR/3-230V and LLG/3-230V); – Yellow or red light scattering globe; – Thermoplastic box; – Protected to IP 55.

A

P

• Only version 230V: – Trimmer to regulate lamp flashing frequency, from 1 to 6 flashes/sec; – Double power input for either a fixed or a IIIflashing light source; – Mother board protection fuse.

B TECHNICAL DATA AND OPERATING POWERS

50

MODEL

CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

LLR/10-230V

251.66

10

0,18

90

90

65

RED, BOX VERSION

LLG/10-230V

251.67

10

0,18

90

90

65

YELLOW, BOX VERSION

LLR/3-24Vac

251.68

3

0,17

90

90

65

RED, BOX VERSION

LLG/3-24Vac

251.69

3

0,17

90

90

65

YELLOW, BOX VERSION

LLR/3-12Vcc

251.84

3

0,17

90

90

65

RED, BOX VERSION

LLG/3-12Vcc

251.85

3

0,17

90

90

65

YELLOW, BOX VERSION

www.manieroelettronica.it

NOTE


COMPLEMENTARY PHASE MONITORING EQUIPMENT WITH ALARM

CSFA2/M-...V Phase sequence monitoring device with alarm (modular unit)

All items of complementary equipment for monitoring phase presence and unbalance are equipped with lower and upper voltage threshold monitoring devices and alarm outputs. These can be fitted onto any apparatus where the power line is unbalanced and subject to considerable voltage surges and drops but operation continuity and safety is essential.

P

It is also indispensable in situations where the equipment is continually powered by different lines and so phase sequence might be incorrect or unbalanced voltages could be experienced. For other requirements, please contact our technical/sales department.

CONNECTION DIAGRAM

A B RELAY OUTPUT

GENERAL CHARACTERISTICS:

– Electronic phase sequence monitoring; – Power: 3~ 50/60Hz ....V ±10%: – 230 V~ (model: CSFA2/M-230 V); – 400 V~ (model: CSFA2/M-400 V); – Power signal LED; – Relay active LED (normally energised); – Alarm trigger trimmer in the event of a phase decrease in the power voltage;

– Alarm output relay, 1 switch (capacity: 5A 250V ~ resistive load); – Alarm triggered in the following cases: - phase failure; - phase reduction; - phase sequence error; – Enclosure for 1 DIN module made of thermoplastic material; – Protection class IP20.

RCSFA2/M-...V

Phase sequence monitoring control with alarm, modular unit, 8th relay output

P CONNECTION DIAGRAM

A RELAY OUTPUT

B GENERAL CHARACTERISTICS:

– Alarm trigger trimmer, range: +2% to +22% (upper voltage threshold); – Trigger delay trimmer, range: 0.1 – 30 s; – Alarm output relay, 1 switch (capacity: 8A 250V ~ resistive load); – Alarm triggered in the following cases: - phase failure; - power voltage increase/decrease; - phase sequence error; - phase voltage unbalance;

– Electronic phase sequence monitoring; – Power: 3~ 50/60Hz ....V ±10%: – 230 V~ (model: RCSFA2/M-230 V); – 400 V~ (model: RCSFA2/M-400 V); – Power signal LED; – Relay active LED (normally energised); – Alarm signal LED; – Settable start delay (1 s or 6 s); – Alarm trigger trimmer, range: -2% to -22% (lower voltage threshold);

– DIN modular enclosure made of thermoplastic material; – Protection class IP20.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

NOTE

CSFA2/M-230V

838.251

7

0,08

82

17,5

67

CSFA2/M-400V

838.252

13

0,08

82

17,5

67

FROM 320 TO 480 VCA

KCSFA2/M-400V

225.99

2

0,5

90

52

70

WIRED VERSION

RCSFA2/M-230V

838.253

13

0,12

80

22,5

100

DIN MODULAR VERSION

RCSFA2/M-400V

838.254

13

0,12

80

22,5

100

DIN MODULAR VERSION

www.manieroelettronica.it

FROM 160 TO 240 VCA

51


MULTIFUNCTION ELECTRONIC TIMERS, STAR-DELTA AND REACTANCE STARTS

TM1/MFT-24-240V Modular timer, 1 output, Multi Function and Multi-Time

CONNECTION DIAGRAM

P

A POWER SUPPLY

B

ALARM RELAY OUTPUT

GENERAL CHARACTERISTICS: – Relay active LED; – Output relay, 1 switch (capacity: 8A 250V ~ resistive load) – Enclosure for 1 DIN module made of thermoplastic material; – Protection class IP20.

– Multifunction electronic timer; – Multifunction electronic timer; – Power options : • ~ 50/60 Hz 24÷240V ac ±10%; • 24V dc ±10%; – Work function selection trimmer: • Delay on energisation; •Delay on de-energisation;

• Interval; • Control contact opening interval; • Double interval; • Symmetrical cyclical (start with ON or OFF IIIIIIstatus); – Time range selection trimmer (0.1 s – 100 h); – Delay time selection trimmer; – Power signal LED;

TASR/MT-24-240V

Multi Time, Star-delta or reactance start timer

CONNECTION DIAGRAM

P

A DELTA POWER SUPPLY

B

STAR

ALARM RELAY OUTPUT

GENERAL CHARACTERISTICS: WORKING DIAGRAM – Relay active LED; – Output relay, 1 switch with neutral in centre (capacity: 5A 250V ~ resistive load) – Enclosure for 1 DIN module made of thermoplastic material; – Protection class IP20.

– Multifunction electronic timer; – Power ~ 50/60Hz 24÷240Vac ±10%: – Time range selection trimmer; – Star or reactance time selection trimmer (T1=0.1 – 600 s); – Direct reactance or star-delta time selection trimmer (T2=50 – 130 ms); – Power signal LED;

Power Supply

Relay 1

Relay 2

TECHNICAL DATA AND OPERATING POWERS

52

MODEL

CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

TM1/MFT-24-240V

838.255

4

0,08

82

17,5

67

DIN MODULAR VERSION

TASR/MT-24-240V

838.256

4

0,08

82

17,5

67

DIN MODULAR VERSION

KTM1/MFT-24-240V

225.98

4

0,08

82

17,5

67

WIRED VERSION

www.manieroelettronica.it

NOTE


EXCHANGERS AND ELECTRONIC MODULES FOR PANELS

MS20/R Exchanger module for 2 electric pumps (2nd delayed);

WORKING DIAGRAM

GENERAL CHARACTERISTICS:

– Start sequence exchanger for two electric pumps; – Module equipped with connector for link up to all our panels configured for 2 or 3 electric pumps; – The MS20/R module delays pump 2 iiistart by approximately 4” on closure of float iiiswitch 2.

A

PUMP 1 PUMP 2

B

MS40

Exchanger module for 2/3 or 4 electric pumps WORKING DIAGRAM

GENERAL CHARACTERISTICS:

– Start sequence exchanger for 2 - 3 or 4 electric pumps; – Module equipped with connector for link up to all our panels configured for 3 or 4 electric pumps; – Start delay selector for pumps 3 and 4; – Selector for operation with 2 - 3 or 4 electric pumps to allow start sequence switching.

A

PUMP 1 PUMP 2 PUMP 3 PUMP 4 R = 3 seconds

B

MA/1

Alarm module with 1 changeover relay GENERAL CHARACTERISTICS:

– Alarm signal module; – Module equipped with connector for link up to all our pre-configured panels; – This module signals when either the MIN/MAX WATER LEVEL or the overload protection has been triggered; – External output for alarm operation via pressure switch or floating switch (NO contact); – Relay output 1A 250V (resistive load) NO-NC contacts for external alarm control; – Available with flat conductor (100 and 300 mm).

A

B

TECHNICAL DATA AND OPERATING POWERS CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

MS20/R

221.39

0,5

0,03

45

47

15

MS40

221.40

0,5

0,06

50

100

25

OPEN VERSION

MA/1-100mm

221.23

0,5

0,04

50

30

30

OPEN VERSION

MA/1-100mm

221.70

0,5

0,04

50

30

30

VERSION FOR QMD20/SI-2

MA/1-300mm

221.24

0,5

0,04

50

30

30

OPEN VERSION

MODEL

www.manieroelettronica.it

NOTE

OPEN VERSION

53


MCL/2ST

ELECTRONIC MODULES FOR CONTROL PANELS

Timed 2-sensor level control module

The application of electronic modules to our pre-configured panels allow users to extend the system’s range of functions as desired. Great financial savings can be made thanks to our forward thinking at the design stage, which means no labour is required for additional wiring and the power supply is already integrated into the panel’s circuit.

GENERAL CHARACTERISTICS:

– Electronic level control module; – Module equipped with connector for link up to all IIIour preconfigured panels; – 2-sensor input for timed operation control; – Sensor sensing trimmer; – Trigger delay trimmer, range: approx. 5 – 20 min; – FILLING or DRAINING operation mode selectors; – Voltage at sensor ends: approx. 10 V~; – Module suitable for non-inflammable conductive iiiliquids; – Available with flat conductor (90 or 300 mm).

A

B

MCL/3S

3-sensor level control module GENERAL CHARACTERISTICS:

– Electronic level control module; – Module equipped with connector for link up to all iiiour preconfigured panels; – Input for 3 sensors or 2 float switches; – Sensor sensing trimmer; – FILLING or DRAINING operation mode selectors; – Voltage at sensor ends: approx. 10 V~; – Module suitable for non-inflammable conductive iiiliquids; – Available with flat conductor (90 or 300 mm).

A

B

MR/ED-120"

Energisation/de-energisation delay module - 120” GENERAL CHARACTERISTICS:

– Electronic module for timed on/off function; – Module equipped with connector for link up to all iiiour preconfigured panels; – Trigger delay trimmer (approx. 0 - 120”) for iiienergising or de-energising electric pump after, iiirespectively, closure or opening of external control iiicontact (pressure switch/float switch); – Selectors for operation in energised or deiiienergised mode; – Available with 400 mm flat conductor.

A

B

TECHNICAL DATA AND OPERATING POWERS MODEL

54

CODE

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

NOTE

MCL/2ST-300mm

221.04

0,04

50

45

30

OPEN VERSION

MCL/2ST-90mm

221.02

0,04

50

45

30

OPEN VERSION

MCL/3S-300mm

221.05

0,04

50

45

30

OPEN VERSION

MCL/3S-90mm

221.30

0,04

50

45

30

OPEN VERSION

MR/ED-120”-400mm

221.12

0,04

50

45

30

OPEN VERSION

www.manieroelettronica.it


COMPLEMENTARY EQUIPMENT AND ALARM MODULES

MIC/1E-...V-2U Control Interface Module 1 Input - 2 Outputs

GENERAL CHARACTERISTICS: – Module equipped with connector for link up to all our pre-configured panels/ equipment (e.g. self-powered sirens).

– Electronic module with signal-controlled input with power options as below: • 1~ 50/60Hz 12V dc and 12V ac (model: MIC/1E-12V-2U); • 1~ 50/60Hz 24V dc and 12V ac (model: MIC/1E-24V-2U); • 1~ 50/60Hz 230V ac (model: MIC/1E-230V-2U); for interface with relay and switch output (contact capacity: 5A 250V~ resistive load) 1 switch on terminal board and 1 switch on connector;

A

B

GENERAL CHARACTERISTICS:

– Ambient temperature -5/+40°C; – relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

MIC/1E-12V-2U

221.25

1

0,05

45

40

40

OPEN VERSION

MIC/1E-24V-2U

221.26

1

0,05

45

40

40

OPEN VERSION

MIC/1E230V-2U

221.27

1

0,05

45

40

40

OPEN VERSION

MODEL

CTIM/...V

NOTE

Motor Seepage Temperature Check

P

CTIM is an electronic detector for signalling over temperature and seepage of water into the oil chamber of an electric motor. The CTIM is ideal not only for submersible electric pumps but also for all electric pumps provided with bimetal temperature sensor (N.C. contact) and water seepage probes.

A

GENERAL CHARACTERISTICS:

- module with electronic control for temperature probe and seepage for electric pumps - power supply : ~ 50/60Hz 220-240V/24 Vac ±10% ~ 50/60Hz 24 V ±10% - n. 2 low voltage inputs for: • Temperature probes of micro thermostat or thermistor PTC types • Probes for seepage type with steel electrode - Contact input for alarms visualisation memory - n. 3 contact outputs NC (250V ~ 5A resistive load for: • stop of the motor • alarm motor over temperature • alarm seepage of water inside the motor - Internal LEDS for signalling: • power supply and regular functioning • alarm motor over temperature • alarm seepage of water inside the motor - n. 4 microswitches for setting of:

B

NEW CT DU PRO

• stop of the motor for alarm over IIIIIItemperature • stop of the motor for alarm seepage of IIIIIIwater inside the motor • manual resetting for restart of the IIIIIImotor in case of normal functions • intermittent output for lighting of the IIIIIILED for seepage alarm - Thermoplastic box - Protection degree IP20. Upon request: - 2 wires seepage sensor – Ambient temperature -5/+40°C; – relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

NOMINAL POWER W

WEIGHT

DIMENSIONS mm B

DIMENSIONS mm P

NOTE

kg

DIMENSIONS mm A

CTIM/24V

253.61

2

0,4

86

49

35

MODULAR DIN VERSION

CTIM/230V

253.62

2

0,4

86

49

35

MODULAR DIN VERSION

www.manieroelettronica.it

55


CL../3S

ELECTRONIC LEVEL CONTROLS

Level control for 3 level sensors on Undecal or Octal base

The level controls for use in numerous applications (such as tanks, reservoirs, protection against electric pumps dry running and for various drinking liquids, water, flammable liquids, etc.) are available for all the most common voltages and in 23 different models but you can also ask for models with other functions you do not find in the catalogue and at no extra charge.

CONNECTION DIAGRAM 130#&4

A 3&-": 065165

P

B

108&3 4611-: */165

GENERAL CHARACTERISTICS: – Main pilot light; – Level sensors sensitivity adjustment trimmer; – Power contacts output relay: 1 exchange 5A 250V~ (resistive load).

– Electronic level control; – Power supply 1~ 50/60Hz 230±10%; – Very low voltage input for external control from level sensors or float/pressure switch; – Voltage at level sensors ends approx 10V ~; – Suitable for non conductive and non flammable liquids;

OPTIONAL: – Octal base version female code 913.025 (see last pages); – Undecal base version female code 913.027 (see last pages).

CLM/3S... CLM/2ST...

Modular level control for 3 level sensors Level control for 2 timed level sensor

P

WORKING DIAGRAM CLM/2ST

WORKING DIAGRAM CLM/3S

A

130#&4$0.."9 034-41."9

108&34611-:

130#&4$0..*/ 034-41.*/

130#&44-4-

&.15:*/(

3&-":065165/0

3&-":065165/$ '*--*/(

B

130#&44-4- 3&-":065165/0

GENERAL CHARACTERISTICS:

– Level sensors sensitivity adjustment trimmer; – Power contacts output relay: 1 exchange 5A 250V~ (resistive load); – Thermoplastic box; – Protection degree IP 20.

– Electronic level control; – Power supply 1~ 50/60Hz ...V ±10%: • 24/48V~ (model CLM/3S-24-48V); • 110/230V~ (model CLM/3S-110-230V); • 230V~(model CLM/2ST-230V); – Voltage at level sensors ends approx: 10V ~; – Suitable for not conductive and not flammable liquids; – Main pilot light;

CHARACTERISTICS CLM/3S: – Very low voltage input for external control from level sensors or float/pressure switch.

54&5%&-":'30.4&$0/%450.*/65&4

CHARACTERISTICS CLM/2ST: – 2 level sensors input for timed operation.

TECHNICAL DATA AND OPERATING POWERS CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

CLU2/3S-230V

632.310

1,5

0,2

80

33

75

UNDECAL BASE VERSION

CLU2/3S-24V

632.311

1,5

0,2

80

33

75

UNDECAL BASE VERSION

CLO/3S-230V

251.86

2

0,23

105

45

60

OCTAL BASE VERSION

CLB/3S-230V

251.41

2

0,4

130

110

65

BOX VERSION

CLB/3S-400V

251.42

2

0,4

130

110

65

BOX VERSION

CLM/2ST-230V

253.27

2

0,50

90

105

70

DIN MODULAR VERSION

MODEL

56

www.manieroelettronica.it

NOTE


ELECTRONIC LEVEL CONTROLS

CLM2/3S-24V Level control for 3 level sensors on Undecal or Octal base

A

P

B

GENERAL CHARACTERISTICS: GENERAL CHARACTERISTICS: - Electronic level control - Power supply 50/50 Hz 24V +- 10% - Voltage at level sensors ends approx. 7,5V - Level control for conductive inflammable liquids - Main pilot light

- Level sensors sensitivity adjustment trimmer - Power contacts output relay: 1 exchange 8A 250V (resistive load) - Thermoplastic box - Protected to IP20

CLM2/3S-24-230V P

A

B GENERAL CHARACTERISTICS: GENERAL CHARACTERISTICS: -

Electronic level control Power supply 24-240 Vac/Vcc Voltage at level sensors ends approx. 7,5V Level control for conductive inflammable liquids Main pilot light

-

Level sensors sensitivity adjustment trimmer Filling and emptying function Power contacts output relay: 1 exchange 8A 250V (resistive load) Thermoplastic box Protected to IP20

TECHNICAL DATA AND OPERATING POWERS CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

CLM2/3S-24V

632.315

1,8

0,22

CLM2/3S-24-230V

632.316

1,2

0,22

MODEL

DIMENSIONS mm B

DIMENSIONS mm P

100

36

55

DIN MODULAR VERSION

100

17,5

55

DIN MODULAR VERSION

www.manieroelettronica.it

NOTE

57


SM2R/24V SM2R/240V

ELECTRONIC EXCHANGERS AND SEQUENCER

Exchanger for 2 pumps

Whenever it is necessary to switch a sequence from 2 to 4 loads (motors, lamps, electric pumps, etc.) we propose, for all the most common voltages, a range of 17 models of electronic switches-sequencers with the possibility, at no extra charge, to ask for other models with different characteristics.

WORKING DIAGRAM

A RELAY 1 RELAY 1

B

P

GENERAL CHARACTERISTICS:

GENERAL CHARACTERISTICS:

- Electronic Exchanger - Power supply 50/50 Hz … +- 10% • 24V (model SM2R/24V) • 240V (model SM2R/240V) - the module delays the start up of the 2 pump of III4” at the closure of all the floats - Main pilot light

-

S..4/...V

Exchanger - sequencer (in 2 versions) for 4 electric pumps

Main pilot light Red LED of output status relays Very low voltage for external control from pressure or float switches Contact capacity n. 2 output relays: 1 NO 8 A 250V (resistive load) 3 DIN modules thermoplastic box Protected to IP20

WORKING DIAGRAM on off on off on off on off

A PUMP 1

on off

PUMP 2

on off

PUMP 3 PUMP 4

P

B

R = 3 seconds

on off on off on off

GENERAL CHARACTERISTICS:

BOX VERSION SB4/230-400V: pumps; – Power contacts of N° 4 output relays: 1 (NO) 10A 250V~ (resistive load); – Selector for delayed start for 3rd and 4th pumps.

– Electronic exchanger-sequencer; – Power supply 1~ 50/60Hz 230/400V±10%; – Very low voltage inputs for external control from pressure or float switch; – Main pilot light; – N° 4 motor control lights; – Selector for exchange to 2, 3 or 4 electric

– Output with cable holder; – Protection degree IP 55. OPEN VERSION: SG4/230-400V: – Electronic card equipped with fastening distance brackets.

TECHNICAL DATA AND OPERATING POWERS CODE

NOMINAL POWER W

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

SM2R/24V

632.317

2

0,25

90

53,5

60

SM2R/240V

632.318

2

0,25

90

53,5

60

DIN MODULAR VERSION

SU2/24V

251.72

2

0,14

105

45

60

UNDECAL BASE VERSION

SU2/230V

251.74

2

0,24

105

45

60

UNDECAL BASE VERSION

SB4/230-400V

251.78

4

1,00

150

200

80

BOX VERSION

SG4/230-400V

251.77

4

0,50

105

145

70

OPEN VERSION

MODEL

58

www.manieroelettronica.it

NOTE

DIN MODULAR VERSION


ELECTRONIC PROBES FOR CONTROL LEVEL

SL1/... Level sensors 1 electrode with and without cable

B

GENERAL CHARACTERISTICS:

B

A

– Unipolar level sensor; – Inox steel 70mm electrode; – PVC covering; – In level sensors without cable, the terminal input is equipped with a goble gland; – In level sensors with cable the terminal is immersed in resin; – Working temperature: max 40°C; – On request level sensors with cable can be IIIsupplied in different cable lenghts.

A

Code 851.049

Code 220.26-27

SL1/1/2" GAS - 6B - 60°C

Level sensors 1 electrode fitting 1/2" Gas - 6 Bar - 60°C GENERAL CHARACTERISTICS:

– Unipolar level sensor; – Inox steel 250mm electrode; – PVC covering; – Gas nickel plated brass connection 1/2”; – Connection by connector; – Working pressure max 6 bar; – Working temperature max 60°C; – IP 65.

B

A

Code 220.30

SL2/2,5M - 1/2" GAS

Level Sensor with 2 electrods with 2,5m cable, 2,5M , 1/2" Gas connection GENERAL CHARACTERISTICS:

– Bipolar level sensor; – Inox steel AISI 303 electrodes; – PVC covering; – Connection 1/2” Gas M. (with O ring); – Output cable 2,5 m PVC; – Working pressure max 4 bar 50’ C; – Protected to IP 67.

B

A

Note: This sensor is for level sensoring only.

Code 220.81

TECHNICAL DATA AND OPERATING POWERS DIMENSIONS mm A

DIMENSIONS mm B

0,06

95

20

PROBE WITHOUT CABLE

0,08

110

16

PROBE WITH 1m CABLE

220.26

0,15

110

16

PROBE WITH 5m CABLE

SL1/10m

220.27

0,20

110

16

PROBE WITH 10m CABLE

SL1/1/2” Gas6B-60°C

220.30

0,12

335

32

PROBE WITHOUT CABLE

SL2/2,5m - 1/2” Gas

220.81

0,25

80

32

BIPOLAR PROBE WITH 2,5 M CABLE

UNIPOLAR CABLE S1

704.188

---

---

---

SILICON CABLE FOR PROBES

MODEL

CODE

WEIGHT kg

SL1/00

851.049

SL1/1m

220.31

SL1/5m

www.manieroelettronica.it

NOTE

59 59


CONTROLPRES/M2,2kW-230V

ELECTRONIC AND ELECTROMECHANICAL PRESSURE SWITCHES Controlpres and Presscontrol are new concept devices which guarantee excellent control of slave pumps in water systems. By-products of a hydraulics and electronic logics project, these units simultaneously detect pressure and flow rate, as well as providing automatic pump operation management. They are designed to replace the traditional expansion tank system. No air charging is required, and troublesome pressure and flow variations are eliminated. The device also protects the pump from dry running. No adjustments or maintenance of any kind required. Far more compact than traditional systems, they are totally reliable, resistant, and easy to install.

CONTROLPRES single-phase 2,2kW 230V~

DIAGRAM OF PRESSURE LOSSES IMPUT PRESSURE

A

P

B

GENERAL CHARACTERISTICS: HYDRAULIC SECTION CONSTRUCTION FEATURES:

– Power ~ 50/60Hz 230 V±10%;: – Pump start and stop feature regulated by opening or closure of user device contacts; – Constant pressure reduction and maintenance during use; – Pump shutdown in the event of water shortage; – Reduced water hammer effects; – Enclosure made of self-extinguishing plastic; – Max operating pressure:12 bar; – Restart pressure: 3 bar (factory setting); – Pressure adjustment range: 2.5 - 7 bar; – Male coupling Gc 1” 1/4; – Pressure gauge coupling Gc 1/4; – Relay output with special contact and electrical life of over 300, 000 cycles non-stop with max. load: 2.2 kW; – Supplied complete with pressure gauge; – Protection class IP 65.

OPERATING CONDITIONS:

– Flow-sensitive valve; – Check valve; – Internal system pressure reduction valve; – External pressure adjustment dial; – Pressure-sensitive diaphragm and spring.

– Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C. ELECTRONIC SPARE PARTS: –Mother board, Code 851.059.

ELECTRONIC SECTION CONSTRUCTION FEATURES: Sealed enclosure made of self-extinguishing plastic; – Individually tested electronic circuit board with tracks protected by insulating film; – Varistor for protection against voltage peaks.

TECHNICAL DATA AND OPERATING POWERS MODEL

CONTROLPRESS/M-2,2kW-230V

60

CODE

OPERATING CURRENT (A)

WORKING MAX PRESSURE (BAR)

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

851.068

16

12

2,7

205

211

297

www.manieroelettronica.it


ELECTRONIC PRESSURE SWITCHES

PRESS/M-1,1kW-230V PRESScontrol Singlephase 1,1kW 230V~

– Starts and stops the pump when the service is opened or closed, activated or deactivated; – Maintains pressure at a constant level during operations; – Shuts off the pump in the event of water failing to reach the inlet; – Fluid tight box moulded in self-extinguishing plastic material; – Restart pressure of 1,5 BAR non-adjustable; – One-inch attachments; – Protection degree IP 65.

A

P

B

CONSTRUCTION CHARACTERISTICS OF THE HYDRAULIC PARTS:

GENERAL CHARACTERISTICS:

– Valve responsive to variations in flow; – Check valve; – Safety valve preventing any leakage of water in the event of the membrane breaking down; – Membrane and spring responsive to variations in pressure.

– Power supply 1~ 50/60Hz 230V±10%; – Relay with special contacts and an electrical life expectancy of over 300.000 cycles continuous rating at maximum load of 1,1 kW;

CONSTRUCTION CHARACTERISTICS OF THE ELECTRONIC PARTS: – Fluid tight box moulded in self-extinguishing plastic material; – Electronic circuit boards individually tested and checked with tracks protected by insulated film, cabled on the relative section of the box. ELECTRONIC SPARE PARTS: Box electronic mother board for PRESS control BSE/PRESS-1,1kW-230V code 851.065. OPERATING CONDITIONS: Ambient temperature –5 to +40°C; – Relative moisture 50% with a max temperature of 40°C.

TECHNICAL DATA AND OPERATING POWERS CODE

OPERATING CURRENT (A)

WORKING MAX PRESSURE (BAR)

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

PRESS/M-1,1kW-230V

851.064

16

10

1,4

170

170

230

BSE/PRESS-1,1kW-230V

851.065

-

-

0,4

111

170

50

MODEL

IPE/...BAR-...V

Electromechanic pressure switch GENERAL CHARACTERISTICS:

Power supply 1~ 50/60 Hz 230 ±10%; – 1/4” screwed gas flange, female; – Polyester box; – 1,5kW maximum load; – Ambient temperature -30/+80°C; – Fluid max temperature 70°C; – Maximum operating frequency: 600 manoeuvre cycles per hour; – Protection degree IP 20.

A

P

B

TECHNICAL DATA AND OPERATING POWERS CODE

PRESSURE (BAR)

POWER (W)

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

IPE/5BAR-230V

851.120

1,4 ÷ 4,6

1,5

0,35

102

72

96

IPE/7BAR-230V

851.121

2,8 ÷ 7

1,5

0,35

102

72

96

IPE/10BAR-230V

851.122

5,6 ÷ 10,5

1,5

0,35

102

72

96

MODEL

www.manieroelettronica.it

61


FLOAT SWITCHES

IGS/...m Watertight float switches

Our electromechanical floating and pressure switches are offered for all hydraulic systems, in particular, for our overflow protection kits. The cable available for the floating switches comes in a variety of types and lengths.

GENERAL CHARACTERISTICS:

– Silver contacts; – Contacts capacity 10(4) A at 250V~; – Microswitch: 1 exchange contact; – Thermoplastic box; – Max temperature: 40°C; – Protection degree IP 67.

B

A P

A N.B.: the counterweight should be ordered separately.

B TECHNICAL DATA AND OPERATING POWERS CODE

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

IGS/5m

851.102

0,60

160

90

45

FLOAT SWITCH WITH 5m PVC CABLE

IGS/10m

851.103

1,20

160

90

45

FLOAT SWITCH WITH 10m PVC CABLE

IGS/20m

851.104

2

160

90

45

FLOAT SWITCH WITH 20m PVC CABLE

CGS (a richiesta)

851.100

0,12

70

58

-

IGS/CN-5m

851.106

0,60

160

90

45

FLOAT SWITCH WITH 5m NEOPRENE CABLE

IGS/CN10m

851.107

1,20

160

90

45

FLOAT SWITCH WITH 10m NEOPRENE CABLE

IGS/CN-20m

851.108

2,20

160

90

45

FLOAT SWITCH WITH 20m NEOPRENE CABLE

MODEL

IGS-.../10m-AR

NOTE

COUNTERWEIGHT FOR FLOAT SWITCHES

Watertight mechanical float switch for sewage GENERAL CHARACTERISTICS: WORKING: – Watertight to a depth of 100m, resistant to humidity and condensation; – External box in a single piece of blowmolded polyethylene; – Internal counterweight to adjust the centre of gravity towards the cable entry point and to determine the rotation point; - it is built with innovative electrical contacts made up of a 10A 250Vca change-over switch with self-cleaning contacts and a high opening distance. – Protection degree IP68.

A

– Regulation for particularly turbulent industrial water with suspended binding residues or ii water laden with sewage waste; – Where there is a deep and narrow sump pit controlling the flow on two different levels.

OPERATING CONDITIONS: – max working temperature 55°C.

B

N.B.: the counterweight should be ordered separately.

TECHNICAL DATA AND OPERATING POWERS MODEL

CODE

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

IGS-MC/10m-AR

851.079

1,30

175

80

-

MECHANICAL SWITCH WITH 10m CABLE

CGS (on request)

851.100

0,12

70

58

-

COUNTERWEIGHT FOR WATERTIGHT FLOAT SWITCH

62

www.manieroelettronica.it

NOTE


ACCESSORIES FOR PANELS

www.manieroelettronica.it

63


ACCESSORIES FOR PANELS: TIMER, RUN HOUR METERS

MTG/P-1-96 Mechanical daily timer module for panel, 1 output, 96 commutations, wired into panel.

The daily, weekly and hourly timers are available either individually or already wired into the panels; in the latter case, the cost includes parts and labour. Equipment of this kind is useful for special cyclical requirements involving switching electric pumps, solenoid, valves etc. on or off. GENERAL CHARACTERISTICS:

P

– Power: 1~ 50/60Hz 230V ± 15%; – Output switch contact: 10A 250 V~ (resistive load); – Reserve charge: 100 h after 48 h non-stop charging; – 96 commutations (48 on and 48 off) with unlosable tappets; – Minimum manoeuvre time: 15 minutes; – Can be wall- or panel-mounted ; – Wiring cable kit; – Standard size dial (72x72).

A

B Code 670.083

MTG/M-1

Mechanical daily timer module for panel, wired into panel.

P

GENERAL CHARACTERISTICS:

– Power: 1~ 45/60Hz 230V ±15%; – Output switch contact: 16A 250 V~ (resistive load); – Reserve charge: 100 h after 48 h non-stop charging; – 96 commutations (48 on and 48 off) with unlosable tappets; – Minimum manoeuvre time: 15 minutes; – Enclosure: 2 DIN modules, made of selfextinguishing thermoplastic material; – Wiring cable kit; – Protection class IP 20.

A

B Code 670.103

MTG/1-1U

Mechanical daily timer module, 1 module with 1 output, wired into panel.

P

GENERAL CHARACTERISTICS:

– Power: 230V~ ±15% 45/60Hz: – N.O. output contact 10A 250V~ resistive load; – Reserve charge: 100 h after 48 h non-stop charging; – 96 commutations (48 on and 48 off) with unlosable tappets; – Minimum manoeuvre time: 15 minutes; – Enclosure: Enclosure for 1 DIN module made of self-extinguishing thermoplastic material; – Wiring cable kit; – Protection class IP 20.

A

B Code 670.093

TECHNICAL DATA AND OPERATING POWERS CODE

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

NOTE

DAILY TIMER FOR PANEL

670.083

0,20

94

72

65

WALL FIXING OR PANEL VERSION

MTG/P-1-96 TIMER (WIRED*)

221.18

0,25

94

72

65

WALL FIXING OR PANEL VERSION

MODULAR DAILY TIMER

670.103

0,11

80

35

59

DIN MODULAR VERSION

MTG/M-1 TIMER (WIRED*)

221-14

0,16

80

35

59

DIN MODULAR VERSION

MODULAR DAILY TIMER

670.093

0,07

90

17,5

60

DIN MODULAR VERSION

MTG/1M-1U TIMER (WIRED*)

221.11

0,08

90

17,5

60

DIN MODULAR VERSION

MODEL

* All the parts and accessories described as “wired” are supplied pre-wired into the equipment ordered and are priced accordingly (labour included). For all other parts and accessories, the price quoted refers to the loose item.

64

www.manieroelettronica.it


ACCESSORIES FOR PANELS:

MTS/P-1-84 Mechanical weekly timer module for panel, 1 output, 84 commutations, wired into panel

TIMER, RUN HOUR METERS

GENERAL CHARACTERISTICS:

P

– Power: 1~ 50/60Hz 230V ± 15%; – Output switch contact: 10A 250 V~ (resistive load); – Reserve charge: 100 h after 48 h non-stop charging; – 96 commutations (48 on and 48 off) with unlosable tappets; – Minimum manoeuvre time: 15 minutes; – Can be wall- or panel-mounted ; – Wiring cable kit; – Standard size dial (72x72).

A

B Code 670.086

MTS/7

Mechanical weekly timer module, 7-day, wired into panel.

P

GENERAL CHARACTERISTICS:

A

B Code 670.106

KCO/...-V

– Programmable weekly/daily timer module; – Power: 1~ 50/60Hz 230V ± 10%; – Output switch contact: 16A 250 V~ (resistive load); – Reserve charge: 5 years after 24 h charging; – 1440 commutations (720 on and 720 off), repeatable in blocks of days; – Minimum settable interval and hourly resolution: 1 second; – Wiring cable kit; – Enclosure: 2 DIN modules, made of selfextinguishing thermoplastic material; – Protection class IP20.

Kit for run hour meter wired into panels

P

GENERAL CHARACTERISTICS:

– – – – –

A

B

Analog run hour meter; Power: 24V~ 0 230V; Operating frequency: 50 Hz; Resolution: 36 seconds or 6 minutes; Capacity: 5 digits (analog hourly timer).

Code 670.094-069

TECHNICAL DATA AND OPERATING POWERS MODEL

MTS/P-1-84 TIMER (WIRED*)

CODE

WEIGHT kg

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

NOTE

221.19

0,25

94

72

65

WALL FIXING OR PANEL VERSION

670-086

0,20

94

72

65

WALL FIXING OR PANEL VERSION

MTS/7 TIMER (WIRED*)

221.15

0,18

85

35

57

DIN MODULAR VERSION

MODULAR WEEKLY TIMER

670.106

0,13

85

35

57

DIN MODULAR VERSION

KCO/MP-5-230V (WIRED*)

225.32

0,18

52

52

70

PANEL VERSION

KCO/MP-5-24V (WIRED*)

225.34

0,18

52

52

70

PANEL VERSION

MECHANIC RUN HOUR METER 24V

670.094

0,17

52

52

70

PANEL VERSION

MECHANIC RUN HOUR METER 230V

670.096

0,14

52

52

70

PANEL VERSION

PANEL WEEKLY TIMER

* All the parts and accessories described as “wired” are supplied pre-wired into the equipment ordered and are priced accordingly (labour included). For all other parts and accessories, the price quoted refers to the loose item.

www.manieroelettronica.it

65


ACCESSORIES FOR PANELS: CAPACITORS

CAPACITORS FOR MOTOR STARTING MODEL

CODE

CAPACITY μF

NOTE

COND/2 μF

643.291

2

DOUBLE FASTON WITHOUT BOLT

COND/2,5 μF

643.292

2,5

DOUBLE FASTON WITHOUT BOLT

COND/3,15 μF

643.293

3,15

DOUBLE FASTON WITHOUT BOLT

COND/4 μF

643.299

4

DOUBLE FASTON WITHOUT BOLT

COND/6 μF

643.294

6

DOUBLE FASTON WITHOUT BOLT

COND/8 μF

643.295

8

DOUBLE FASTON WITHOUT BOLT

COND/10 μF

643.297

10

DOUBLE FASTON WITHOUT BOLT

COND/12,5 μF

643.298

12,5

DOUBLE FASTON WITHOUT BOLT

COND/16 μF

643.300

16

DOUBLE FASTON WITHOUT BOLT

COND/20 μF

643.302

20

DOUBLE FASTON WITHOUT BOLT

COND/25 μF

643.303

25

DOUBLE FASTON WITHOUT BOLT

COND/30 μF

643.304

30

DOUBLE FASTON WITHOUT BOLT

COND/35 μF

643.305

35

DOUBLE FASTON WITHOUT BOLT

COND/40 μF

643.306

40

DOUBLE FASTON WITHOUT BOLT

COND/45 μF

643.308

45

DOUBLE FASTON WITHOUT BOLT

COND/50 μF

643.309

50

DOUBLE FASTON WITHOUT BOLT

COND/60 μF

643.310

60

DOUBLE FASTON WITHOUT BOLT

COND/70 μF

643.311

70

DOUBLE FASTON WITHOUT BOLT

COND/75 μF

643.313

75

DOUBLE FASTON WITHOUT BOLT

COND/80 μF

643.312

80

DOUBLE FASTON WITHOUT BOLT

CAPACITOR KIT COMPLETE WITH WIRING MODEL

CODE

CAPACITY μF

NOTE

KCC/16

226.16

16

Wired capacitor kit*

KCC/20

226.20

20

Wired capacitor kit*

KCC/25

226.25

25

Wired capacitor kit*

KCC/30

226.30

30

Wired capacitor kit*

KCC/35

226.35

35

Wired capacitor kit*

KCC/40

226.40

40

Wired capacitor kit*

KCC/45

226.45

45

Wired capacitor kit*

KCC/50

226.50

50

Wired capacitor kit*

KCC/60

226.60

60

Wired capacitor kit*

KCC/70

226.70

70

Wired capacitor kit*

KCC/75

226.75

75

Wired capacitor kit*

KCC/80

226.80

80

Wired capacitor kit*

SWITCHES AND COMMUTATORS MODEL

CODE

ISOLATING VOLTAGE

NOTE

SWITCH 12A

670.120

660

CAM SWITCH (0-1) 12A 1POLE

SWITCH 16A

670.124

660

CAM SWITCH (0-1) 16A 1POLE

SWITCH 20A

670.239

660

CAM SWITCH (0-1) 20A 2POLES

COMMUTATOR 12A

670.134

660

CAM COMMUTATOR (1-0-2) 12A 1POLE

GASKET

670.133

-

RUBBER GASKET FOR IP 54

CV/FF (WIRED*)

225.60

660

CAM VOLTMETRIC COMMUTATOR

HD1216+F112

670.252

660

CAM VOLTMETRIC COMMUTATOR

* All the parts and accessories described as “wired” are supplied pre-wired into the equipment ordered and are priced accordingly (labour included). For all other parts and accessories, the price quoted refers to the loose item.

Code 670.134

66

www.manieroelettronica.it


ACCESSORIES FOR PANELS: VOLTMETERS, AMMETERS ALSO WIRED We offer voltmeters and ammeters which can be fitted, on request, on all our panels. We supply the instrument either alone or wired into the panels; in the latter case, the cost includes cables and wiring, which means, once you have chosen the panel, simply add on the price of the ‘wired kit’ to find out the total cost of the product. In some rare cases it may be necessary (for reasons of space) to upgrade to a larger enclosure. Our sales department will let you know how much this will cost when they receive your order (if not agreed beforehand). To choose the right voltmeter, see the voltage specified in the model column, while for the ammeter, you will need to check the capacity (in kW) of the panel you intend to fit the instrument onto. Example: for a three-phase 5 kW panel, you will need the Voltmeter/ Ammeter Kit mod. K-V-A/2,2-5,5kW code 225.82.

VOLTMETERS/AMMETERS ANALOG FOR BOXES CODE

TYPE OF CURRENT MEASURED

NOTE

30V

850.052

DC

PANEL MOUNTED 48x48x62

300V

850.005

AC

PANEL MOUNTED 72x72x76

500V

850.004

AC

PANEL MOUNTED 72x72x76

CAPACITY OF AMMETER

CODE

TYPE OF CURRENT MEASURED

NOTE

10A

850.053

DC

PANEL MOUNTED 48x48x62

5A (2xIn)

850.014

DC

PANEL MOUNTED 72x72x80

15A (2xIn)

850.021

DC

PANEL MOUNTED 72x72x80

25A (2xIn)

850.019

DC

PANEL MOUNTED 72x72x80

40A (2xIn)

850.020

DC

PANEL MOUNTED 72x72x80

(2xIn) (2xIn)

850.150

AC WITH T.A.

PANEL MOUNTED 72x72x80

60A (2xIn)

850.018

AC WITH T.A.

PANEL MOUNTED 72x72x80

150A (2xIn)

850.032

AC WITH T.A..

PANEL MOUNTED 72x72x80

250 (2xIn)

850.030

AC WITH T.A..

PANEL MOUNTED 72x72x80

CAPACITY OF VOLTMETER

VOLTMETERS/AMMETERS ANALOG FOR BOXES MODEL

CODE

TYPE VOLTMETER

NOTE

KV/300V

225.78

Voltmeter 300V

f. s. for single phase panels

KV/500V

225.79

Voltmeter 500V

f. s. for three phase panels

MODEL

CODE

TYPE AMMETER

NOTE

KA/0,37-2,2kW

225.70

Ammeter 25A(2xIn)

f. s. for single phase panels

KA/0,37-1,5kW

255.71

Ammeter 5A(2xIn)

f. s. for three phase panels

KA/2,2-5,5kW

225.72

Ammeter 15A(2xIn)

f. s. for three phase panels

KA/7-10kW

225.73

Ammeter 40A(2xIn)

f. s. for three phase panels

KA/11-22kW

225.74

Ammeter 60A(2xIn)

f. s. for three phase panels

KA/30-55kW

225.75

Ammeter 150A(2xIn)

f. s. for three phase panels

KA/59-75kW

225.76

Ammeter 250A(2xIn)

f. s. for three phase panels

KA/90-150kW

225.77

Ammeter 400A(2xIn)

f. s. for three phase panels

MODEL

CODE

NOTE

K-V-AM/0,37-2,2kW

225.80

Voltmeter 300V f. s., Ammeter 25A (2xIn) f. s. for single phase panels

K-V-A/0,37-1,5kW

225.81

Voltmeter 500V f. s., Ammeter 5A(2xIn) f. s. for three phase panels

K-V-A/2,2-5,5kW

225.82

Voltmeter 500V f. s., Ammeter 15A (2xIn) f. s. for three phase panels

K-V-A/7-10kW

225.83

Voltmeter 500V f. s., Ammeter 40A (2xIn) f. s. for three phase panels

K-V-A/11-22kW

225.84

Voltmeter 500V f. s., Ammeter 60A (2xIn) f f. s. for three phase panels

K-V-A/30-55kW

225.85

Voltmeter 500V f. s., Ammeter 150A (2xIn) f. s. for three phase panels

K-V-A/59-75kW

225.86

Voltmeter 500V f. s., Ammeter 250A (2xIn) f. s. for three phase panels

K-V-A/90-150kW

225.87

Voltmeter 500V f. s., Ammeter 400A (2xIn) f. s. for three phase panels

www.manieroelettronica.it

67


ACCESSORIES FOR PANELS When choosing an ammeter (see table above), certain capacity A C models may need a current transformer, in this case, this accessory should be selected from the table below.

AMMETRIC TRANSFORMER FOR ALTERNATE CURRENT CODE

TO COUPLE WITH AMMETER

TA/40

850.009

40A

TA/60

850.008

60A

TA/150

850.011

150A

TA/250

850.031

250A

MODEL

NOTE

BASES OCTAL/UNDECAL WIRED INTO THE CONTROL PANELS MODEL

CODE

NOTE

ZUC/CLU

225.23

ZUC/SU2

225.22

BASE UNDECAL VERSION WIRED* FOR SU2/…V

ZUC/CLO

225.25

BASE OCTAL VERSION WIRED* FOR CLO/3S-…V

BASE 11

913.027

UNDECAL BASE VERSION FEMALE

BASE 8

913.025

OCTAL BASE VERSION FEMALE

BASE UNDECAL VERSION WIRED* FOR CLU2/3S-…V

SINGLE-PHASE THERMAL RELAYS, ILLUMINATED SWITCH AND COVERS FOR IP55

A

P B

MODEL

CODE

WEIGHT

DIMENSIONS mm A

DIMENSIONS mm B

DIMENSIONS mm P

T/4A

879.002

0,01

43

35

15

T/5A

879.024

0,01

43

35

15

T/6A

879.004

0,01

43

35

15

T/7A

879.006

0,01

43

35

15

T/8A

879.025

0,01

43

35

15

T/9A

879.026

0,01

43

35

15

T/10A

879.021

0,01

43

35

15

T/12A

879.022

0,01

43

35

15

T/13A

879.023

0,01

43

35

15

T/14A

879.027

0,01

43

35

15

T/15A

879.012

0,01

43

35

15

T/16A

879.028

0,01

43

35

15

T/18A

879.029

0,01

43

35

15

T/20

879.030

0,01

43

35

15

MODEL

68

CODE

NOTE

THERMAL RELAY COVER

879.276

IP55 PROTECTION COVER FOR THERMAL RELAYS

ILLUMINATED SWITCH

670.101

RED BIPOLAR LIGHT SWITCH RANGE CONT. 16A

ILLUMINATED SWITCH COVER

670.102

IP55 PROTECTION COVER FOR SWITCH

COVER SWITCH

644.344

IP55 COVER FOR SYNOPTIC PANEL SWITCHES

PUSH BUTTON COVER

644.345

IP55 COVER FOR SYNOPTIC PANELS PUSH BUTTON

www.manieroelettronica.it


www.manieroelettronica.it


quota-adv.it PRODUZIONE EAND CONTROLLO DELL’ENERGIA PRODUCTION CONTROL OF ENERGY