Page 1

Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold

Rosemount Conventional Manifolds ROSEMOUNT 304 FEATURES AND BENEFITS • Factory assembled, seal-tested and calibrated • Flange by Flange, Flange by NPT, and Wafer styles in 2, 3, and 5-valve configurations • Reduce total installed cost • Easy in-process calibration

Content Rosemount 304 Conventional Manifolds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3 Traditional Style Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 Wafer Style Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7

www.rosemount.com


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold

Rosemount 304 Conventional Manifolds Transmitter Transmitter

Test (Plugged)

Test/Vent Test/ Vent

Isolate

Test/ Vent

Equalize

Isolate

Isolate Process

Process

FIVE-VALVE TWO-VALVE Two-valve manifold is used with Rosemount 1151 and 3051 gage and absolute pressure transmitters. The first valve provides process isolation. The second valve allows capture of vented or drained process, and simplifies in-process calibration.

5–valve manifolds are used with 3051 and 1151 differential pressure transmitters providing two isolation valves, one equalization valve, and two test/vent valves. The two vent valves allow for 100% capture of vented or drained process and simplified process calibration capability. Transmitter

Transmitter

Test (Plugged)

Test (Plugged) Equalize

Isolate

Test (Plugged)

Equalize

Equalize

Isolate Isolate

Process

Test (Plugged)

Isolate

Test/Vent

Process

Process

FIVE-VALVE NATURAL GAS THREE-VALVE (TRADITIONAL STYLE) Three-valve (traditional style) manifolds are used with 3051 and 1151 differential pressure transmitters providing two isolation valves, two plugged test ports, and one equalization valve.

5-valve natural gas manifolds are used with 3051 and 1151 differential pressure transmitters providing two isolation valves, two equalization valves, anad one test/vent valve. The dual equalization valves ensure DP signal integrity.

Transmitter

NOTE Test/Vents receive plastic caps to protect threaded connections unless otherwise noted. Equalize

Isolate

Isolate Process

THREE-VALVE (WAFER STYLE) Three-valve (wafer style) manifolds are used with 3051 and 1151 differential pressure transmitters providing two isolation valves and one equalization valve.

2

NOTE Test (Plugged) connections receive 1/4-in. NPT plug.


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold Specifications

Process Connection

Estimated Weight

Flange by Pipe: 1/2–14 Female NPT process connection

5.0 lbs (2.3 kg) for 2-valve traditional pipe by flange 5.5 lbs (2.5 kg) for 2-valve traditional flange by flange 5.2 lbs (2.4 kg) for 3-valve traditional pipe by flange 5.7 lbs (2.6 kg) for 3-valve traditional flange by flange 4.0 lbs (1.8 kg) for 3-valve wafer thread by flange 5.7 lbs (2.6 kg) for 5-valve wafer thread by flange 5.7 lbs (2.6 kg) for 5-valve traditional thread by flange 5.7 lbs (2.6 kg) for 5-valve traditional flange by flange

Flange by Flange: 21/8-in. (54 mm) center to center connection; Rosemount flange adapters required for 1/2–14 Female NPT. Wafer: 1/2–14 Female NPT process connection

Instrument Connection Direct mounted to transmitter flange, 21/8 in. (54 mm) center to center connection per IEC 61518, Type B shut-off device (without SPIGOT).

Test and Vent Connections 1

/4–18 Female NPT

FIGURE 1. Conventional Manifolds - Pressure vs. Temperature PTFE Packed, Integral Seat Graphite Packed, Integral Seal

ISOLATION VALVE

Pressure psig (bar)

6000 (414) 5000 (345)

Bonnet 4000 (276)

Stem Body

3000 (207)

Packing

2000 (138)

Ball / TIP

1000 (69)

Note: “Typical” Valve 0 0 (-18)

100 (38)

200 (93)

300 (149)

400 (204)

500 (260)

600 (316)

700 (371)

800 (427)

900 (482)

1000 (538)

Temperature °F (°C) CONVENTIONAL MANIFOLDS - PRESSURE AND TEMPERATURE RATINGS Packing

Seat

Pressure and Temperature Ratings

PTFE

Integral

Graphite

Integral

6000 psi @ 200°F (414 bar @ 93°C) 4000 psi @ 400°F (276 bar @ 204°C) 6000 psi @ 200°F (414 bar @ 93°C) 1500 psi @ 750°F (103 bar @ 399°C)

PROCESS WETTED MATERIALS OF CONSTRUCTION- TYPICAL Component

316SST

CS

Body Ball / Tip Stem Packing Bonnet Pipe Plug

316 SST 316 SST /316Ti SST 316 SST PTFE / Graphite 316 SST 316 SST

CS A108(1) Tungsten Carbide 316 SST PTFE 316 SST CS A108

(1) Not available with Wafer Style.

3


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold

Traditional Style Dimensional Drawings Rosemount 304 Two-Valve Flange X NPT Conventional Manifold INSTRUMENT SIDE

φ0.281 Mounting

2.12 (54)

1/4 NPT

Vent

Holes (2) 1

/4 NPT Test 3.75 (95)

6.24 (158) Max Open

1.13 (29)

3.50 (89) Max Open

1 /2 NPT Process Connection on 2.125 (54) Centers (2)

PROCESS SIDE Dimensions are in inches (millimeters)

Rosemount 304 Two-Valve Flange X Flange Conventional Manifold INSTRUMENT SIDE

φ0.281 Mounting Holes (2)

2.12 (54)

1/4 NPT

Vent

1

/4 NPT Test 3.75 (95)

1.13 (29)

3.50 (89) Max Open

6.24 (158) Max Open

7 /16–20–UNF Mounting Holes (4) on a 2.125 x 1.625–in. Hole Pattern

PROCESS SIDE Dimensions are in inches (millimeters)

Rosemount 304 Three-Valve Flange X NPT Conventional Manifold INSTRUMENT SIDE

φ0.281 Mounting

2.12 (54)

Holes (2) 1/4 NPT

Test (2) 3.75 (95)

1.13 (29) 9.11 (231) Max Open

1

3.50 (89) Max Open

PROCESS SIDE Dimensions are in inches (millimeters)

4

/2 NPT Process Connection on 2.125 (54) Centers (2)


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold

Rosemount 304 Three-Valve Flange X Flange Conventional Manifold INSTRUMENT SIDE

φ0.281 Mounting Holes (2)

2.13 (54)

1

/4 NPT Test (2) 3.75 (95)

1.13 (29) 9.11 (231) Max Open

7

3.50 (89) Max Open

/16–20–UNF Mounting Holes (4) on a 2.125 x 1.625–in. Hole Pattern

PROCESS SIDE Dimensions are in inches (millimeters)

Rosemount 304 Five-Valve Flange X NPT Conventional Manifold INSTRUMENT SIDE

φ0.281 Mounting Holes (2)

2.13 (54) 1 /4 NPT Test (2)

3.75 (95)

1/4 NPT

Vent

1.13 (29)

3.5 (89) Max Open

9.11 (231) Max Open

PROCESS SIDE

1 /2 NPT Process Connection on 2.125 (54) Centers (2)

Dimensions are in inches (millimeters)

Rosemount 304 Five-Valve Flange X Flange Conventional Manifold INSTRUMENT SIDE

φ0.281 Mounting

2.13 (54)

Holes (2)

1

/4 NPT Test (2) 3.75 (95) 1/4 NPT

1.13 (29)

9.11 (231) Max Open

3.5 (89) Max Open

Vent

7 /16–20–UNF Mounting Holes (4) on a 2.125 x 1.625–in. Hole Pattern

PROCESS SIDE Dimensions are in inches (millimeters)

5


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold

Wafer Style Dimensional Drawings Rosemount 304 Three-Valve Wafer Manifold INSTRUMENT SIDE

9.00 (229) Max Open

5.00 (127) Max Open

1/2–14

NPT Process Connection (2)

1.25 (32)

PROCESS SIDE 3

/8–16 UNC Mounting Holes (2)

1.50 (38) 3.35 (85)

Dimensions are in inches (millimeters)

Rosemount 304 Five-Valve Wafer Manifold INSTRUMENT SIDE 5.00 (127) Max Open

1.25 (32)

10.63 (270) Max Open 1/4–18

NPT Test/Vent Connection (2)

PROCESS SIDE 3

/8–16 UNC Mounting Holes (2) Dimensions are in inches (millimeters)

6

1.50 (38) 3.35 (85)

1/2–14 NPT Process

Connection (2)


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold Ordering Information

TABLE 1. Rosemount 304 Ordering Information Model

Product Description

0304

Conventional Manifold

Code

Manufacturer

R

Rosemount Inc.

Code

Manifold Style

T W(1)

Traditional (Flange x Flange or Flange x NPT) Wafer

Code

Manifold Type

2(2) 3 5(3) 6(2)

2-valve 3-valve 5-valve 5-valve Natural Gas Metering Pattern

Code

Materials of Construction

1 2

Body CS A108 316 SST

Code B F(2)

Bonnet 316 SST 316 SST

Stem 316 SST 316 SST

Tip Tungsten Carbide 316 SST

Process Connection 1

/2-14 NPT Flanged

Code

Packing Material

1 2(1)

Teflon Graphite-based

Code

Transmitter Type

1 2 4

For assembly to 3051 Traditional Flange For assembly to 3051/3095 DIN Compliant Traditional Flange For assembly to 1151 range 3 - 5

Code

Options

Mounting Bracket Manifold Heavy Duty Mounting Bracket, CS for Traditional Style Manifold Heavy Duty Mounting Bracket, SST for Traditional Style Manifold SST Mounting Bracket for 2-in. pipe mount with series 300 SST bolts for wafer style Transmitter Bracket for 2-in. pipe mounting, CS bolts Transmitter Flat Bracket for 2-in. pipe mounting, CS bolts Transmitter B1 Bracket with series 300 SST bolts Transmitter B3 Bracket with series 300 SST bolts Transmitter SST B1 Bracket with series 300 SST bolts Transmitter SST B3 Bracket with series 300 SST bolts Adapters Flange Adapters DF(4) Bolts L4 Austentic 316 SST Bolts L5 ASTM A 193, Grade B7M Bolts Typical Conventional Manifold Model Number: 0304RT32B11VS VC(2) VS(2) B4 B1 B3 B7 B9 BA BC

(1) Not available with Material of Construction code 1. (2) Not available with Manifold Style code W. (3) Not available with Manifold Style code T. (4) Only allowed with both Manifold Style code T and Process Connection code F. Not allowed with Packing Code 2 (Graphite-based).

7


Product Data Sheet 00813-0100-4839, Rev BA November 2006

Rosemount 304 Manifold

Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. Teflon is a registered trademark of E.I. du Pont de Nemours & Co. All other marks are the property of their respective owners.

Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001

Emerson Process Management Heath Place Bognor Regis West Sussex PO22 9SH England T 44 (0) 1243 863121 F 44 (0) 1243 867554

www.rosemount.com

¢00813-0100-4839w¤ © 2006 Rosemount Inc. All rights reserved.

Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com

Rosemount Conventional Manifolds - November 2006  

• Flange by Flange, Flange by NPT, and Wafer styles in 2, 3, and 5-valve configurations Rosemount 304 Conventional Manifolds. . . . . . . ....

Read more
Read more
Similar to