Issuu on Google+

HANGZHOU PERFECT TECHNOLOGY CO., LTD.

Catalogue MODEL BST-10AD

DC HYSTERESISGRAPH

FUNDAMENTAL P ERFORMANCE PARAMETER

1. SOFTWARE FEATURES..... 1 2. SOFTWARE SCREEN..... 2 3. TECHNICAL DATA..... 3 4. PRODUCT FAMILY..... 4

Copyright © 2010 Hangzhou Perfect Technology Co.,Ltd.


-operating systems, Chinese/English or pure English interface optional, conform to Windows software specification, visual and simple operation. ·Full automatic control, intelligent identification, minimize manual operation. Sampling waveform and instrument status under real-time monitoring, and can be stopped at any time.

SOFTWARE FEATURES

·Automatic completion of data calculation, and temperature conversion of test result. File system adopts database format, can directly print or output test result to Excel form. ·Powerful file management functions: data saving and deleting and remove all the date, etc. ·Data files contain complete sampled data, sample parameters, instrument parameters and testing schemes, adopt text format, can be conveniently typed into other software. ·Display B(H) and J(H) magnetic hysteresis loop or demagnetization curve and B(BH) magnetic energy-product curves, it can display the coordinate information of every data point on curve. ·Simultaneously Display of several testing data’s curve diagram, for example: Demagnetization curve or magnetic hysteresis cycle of same sample under different temperatures, demagnetization curve or magnetic hysteresis cycle of different samples, etc. ·Support various models of printers, test report accurately match printer sheet. ·Print preview function, can conveniently regulate the size and edge distance of test report.Test report can be directly printed, or generate JPG image file.JPG image file can be sent directly through E-mail, or saved into disk. ·Test reports contain complete curve diagrams, test results, test conditions and sample parameters. Both Chinese and English format can be adopted to facilitate adding user mark and enterprise name.


SOFTWARE SCREEN


TECHNICAL DATA

System Specifications

Test AlNiCo standard sample, measuring error on entire magnetic hysteresis cycle estimated: B: 1%, H: 1% Parameters measured

Br (%)

HcB (%)

HcJ (%)

(BH)max (%)

Uncertainty (k = 2)

1

1

1

2

Repeatability (constant temperature)

± 0.3

± 0.3

± 0.3

±1

BST-10AD Test Power Supply

DCT130 Electromagnet

Output Voltage: 0 ~ ±100 V Output Current: ±20 A (maximum value) Stability: superior to 0.05% Output protection: overvoltage, overflowing, short-circuits protection

Head Diameter: 130 mm Head Spacing: 0 ~ 50 mm (continual adjustable) Maximal Magnetic Field: 1.5 T (head spacing 10 mm, coil current 20 A)

BST-10AD Test Power Supply

DCT150 Electromagnet

Supply Voltage: single phase, 220V 50Hz Output Voltage: 0 ~ ±120 V Output Current: ±30 A (maximum value) Output protection: overvoltage, overflowing, short-circuits prote

Head Diameter: 150 mm shrink to 80 mm Head Spacing: 0 ~ 50 mm (continual adjustable) Maximal Magnetic Field: 2.4 T (head spacing 10 mm,coil current 30 A)


BST-10AD Test Power Supply

DCT200 Electromagnet

Supply Voltage: single phase, 220V 50Hz Output Voltage: 0 ~ ±200 V Output Current: ±60 A (maximum value) Output protection: overvoltage, overflowing, short-circuits protection

Head Diameter: 200 mm shrink to 80 mm Head Spacing: 0 ~ 50 mm (continual adjustable) Maximal Magnetic Field: 2.7 T (head spacing 10 mm, coil current 60 A)

BST-10AD Test Power Supply

DCT250 Electromagnet

Supply Voltage: three phase, 380V 50Hz Output Voltage: 0 ~ ±300 V Output Current: ±60 A (maximum value) Output protection: overvoltage, overflowing, short-circuits protection

Head Diameter: 250 mm shrink to 80 mm Head Spacing: 0 ~ 80 mm (continual adjustable) Maximal Magnetic Field: 2.8 T (head spacing 10 mm, coil current 60 A)

LZ-210B Fluxmeter

PC6023 A/D D/A card

Range: 2.5, 5, 10, 20 mWb Full Range Precision: 0.5% Zero Shift: 2 μWb / 30 seconds (2.5 mWb)

LZ-210H Magnetometer Range: 0.5, 1, 1.5, 3 T Full Range Precision: 0.5% Non-Linearity: ±0.2% (software correction)

A/D Conversion: 12 bits, 32 channels Conversion Time: < 10 μs Conversion Accuracy: 0.1% (full range) D/A Conversion: 12 bits, 2 channels Conversion Accuracy: 0.1% (full range) PC6616 A/D D/A card A/D Conversion: 16 bits, 8 channels differential input Conversion Time: < 10 μs Conversion Accuracy: 0.02% (full range) D/A Conversion: 12 bits, 2 channels Conversion Accuracy: 0.1% (full range)

Test


PRODUC FAMILY

STANDARD EQUIPMENT

Serial No. 1

Product Model

BST-10AD 130

BST-10AD 150

BST-10AD 200

BST-10AD 250

Electromagnet Model

DCT130

DCT150

DCT200

DCT250

2

Test Power Supply

2 kW

3 kW

12 kW

18 kW

3

Fluxmeter Configuration

One LZ-210B

4

Magnetometer

LZ-210H

5

Data Acquisition Card

PC6023

6

Measurement Software

7

Computer and Printer

Dell Dimension E-520n computer + HP1020 laser printer

8

Standard Specimen

One AlNiCo standard sample

9

Fixed Coil

One B coil

One J coil

Test Specimen Category

AlNiCo Ferrite

AlNiCo Ferrite NdFeB

10

11

Specimen Size (with round sample as an example)

HMTest partial functions

Diameter 3 ~ 100 mm Thickness 3 ~ 50 mm Ø < 130 - 1.2 H

Two LZ-210B

HMTest all functions

General permanent magnetic: Ø 3 ~ 60 mm H 3 ~ 50 mm Rare earth permanent magnetic: Ø 5 ~ 20 mm H 5 ~ 15 mm

J coil + H coil AlNiCo Ferrite NdFeB SmCo General permanent magnetic: Ø 3 ~ 90 mm H 3 ~ 50 mm Rare earth permanent magnetic: Ø 5 ~ 30 mm H 5 ~ 20 mm

J coil + H coil AlNiCo Ferrite NdFeB SmCo General permanent magnetic: Ø 3 ~ 120 mm H 3 ~ 50 mm Rare earth permanent magnetic: Ø 5 ~ 50 mm H 5 ~ 30 mm


OPTIONS Serial No.

Options Name

Functional Description

1

B Coil

Direct measurement on sample magnetic induction density, winding unnecessary

2

J Coil

Direct measurement on sample magnetical polarization, winding unnecessary

3

Common Head

Work with electromagnet to generate uniform magnetic field

4

Horn Head

Generate larger uniform magnetic field

5

Shrinkage Head

Applies to improve maximal magnetic field of electromagnet

6

Iron Cobalt Head

Can improve maximal magnetic field for about 0.3 T

7

Heat Head

8

9

TCS-200 Temperature Controller Tile Jig

Applies to measure high temperature property of permanent-magnet material Applies to control temperature of heat head, control range: 50 ~ 250째C Applies to measure magnetic shoe

Remark Customized, adaptable to the measurement of general permanent-magnet material Customized, adaptable to the measurement of all permanent-magnet materials DCT130 standard configuration, other models optional All models of electromagnet optional DCT130 optional, other models with standard configuration Only DCT200 and DCT250 optional All models of electromagnet optional Optional, can match with various heat heads Optional parts, customize according to magnetic shoe size, to match electromagnet with corresponding size


10AD DC Hysteresisgraph