COLLECTOR M A G I C S U N EKA2 81

2005

2005

1010

Solar Collector Description

gross dimensions (L x B x H) heater gross area absorber area total mass of collector without fluid fluid content maximum temperature of operation maximum operation pressure absorbation emition yearly energy output of the collector casing material cover material insulation number of tubes and tube diameter connection certificate

2005 mm x 1010 mm x 81 mm 1080 mm 2,025 m² 2,40 m² 38,10 kg 1,920 l 160,3 °C 11 bar 95% ± 2% 5% ± 2% 560 kW/m² / yearly* aluminum 4 mm security prismatic glass 40 mm glasswool 10 x Ø 10 mm 4 x Ø 22 mm EN12975-2 / ISO9806-1 / ISO9806 / Solar Keymark * for the area of Würzburg - Germany


COLLECTOR M A G I C S U N EKA2

heavy-duty-flat collector for on-In and flat roof installation solid aluminum frame ten (10) year warranty

installation system sponsers a quick and easy installation newly developed ventilation system guaranteed mist-free

attractiv design of the collector (all arial colours avalible) vertical and horizontaly use combinible with all commen heating-systems and pools


Laboratory of testing solar and other energy systems ''DEMOKRITOS'' solar Collector Description (EN 12975-2 / ISO 9806-1 / ISO 9806) 1. basic data -sales rep: -manufacturer: -collector model:

Exhellios – E. Bellos & M. Mokas O.C Iliotechnothermiki O.C MAGICSUN EKA2

2. collector -gross area: -gross dimensions: -aperture dimensions (a1 x b2): -absorber area (a2 x b2): -typ of collector: -total mass of collector without fluid: -fluid content: -maximum operating pressure: -maximum temperature of operation:

2,02 m² 2005x1010x81 mm 1925 x 935 mm x mm 2,40 m² flat plate 38,1 kg 1,920 kg 11 bar 160,3 °C

3. aperture -number of covers: -cover thickness (Lc): -cover materials: -optical efficiency (τ):

one (1) 4 prismatic security glass 88,5%

mm τ

4.absorber -absorber type: -absorber material: -constraction type: -absorber thickness (δ): -surface treatment:

one piece aluminum sheet copper tubes omega 0,40 high selective coating

mm


-absorbation (α): -emition (ε): -material of tubes: -number of tubes: -tube diameter (outside) (da): -tube diameter (inside) (di): -tupe pitch (W): -heater diameter (outside) (da): -heater diameter (inside) (di):

0,95 ± 0,02 at 100 °C 0,05 ± 0,02 at 100 °C copper (ten) 10 10,8 mm 10,0 mm 97 mm 22 mm 20,4 mm

5. thermal insulation and casing

-insulation material, back: thermal insulation density: thermal insulation thickness (Li1, Li2): Thermal condutivity (λb)*(in 10 °C): -insulation material, sides: thermal insulation density: thermal insulation thickness (Li1, Li2): Thermal condutivity (λb)*(in 10 °C): -casing material, sides: -casing material, back: -sealing material:

glasswool 50kg/m³ 4 cm 0,032 W/m.K glasswool 30kg/m³ 3 cm 0,33 W/m.K aluminum 1,2 mm aluminum 0,5 mm EPDM rubber strip and silicone


6. sketch of the collector

heater

tubes

absorber

cover

aperture

insulation, sides

casing

insulation, back

casing, back


101

a/a 1

number 1

2

4 4 1 1 1 10 1 2 1 1 4

3 4 5

6 7

description galvanized steel sheet aluminum plastic-corner silicone glasswool absorber heat exchanger pipe absorber surface heater cover plastic-frame plastic-rosettes


INSTALLATION - SET MONTAGE-SET B2 B2B2 Montage-Set

vertikal rod 40x40x200

horizontal rod 40x40x200 x2

roof hook 40x5 x4


Installation of two collectors MAGICSUN EKA2 step 1

step 2


Technical specification single coil floor standing boiler BLC-1 Material: steel sheet Welding: automatic metal welding Protection coating: high quality glass – enamel coating and protection anode Maximum working pressure: 10 bar Maximum working test pressure: 16 bar Maximum operating temperature: 95°C Insulation: polyurethane foam of 50mm thickness, density 40kg/m³ Coil: steel tube Maximum coil test pressure: 25 bar Electric heater: by order Flange: diameter Ø170mm & Ø140mm

Volume L

150

200

250

300

500

600

Code

BLC-1-A

BLC-1-B

BLC-1-C

BLC-1-D

BLC-1-E

BLC-1-F

Coil S input / outlet

1''

1''

1''

1''

1''

1''

Coil surface / m²

0,72

0,986

0,986

1,55

1,55

1,55

R ecirculation

3/4''(1/2'')

3/4''(1/2'')

3/4''(1/2'')

3/4''(1/2'')

1''

1''

Cold water input

1'' 1''

1'' 1''

1'' 1''

1'' 1''

1'' 1''

1 ½''

Hot water outlet Anode - flange

Ø140

Ø140

Ø140

Ø140

Ø140

Ø140

For connection to a boiler with 90°C and water 10/45°C KW/L/h

36 859

41,5 1018

41,5 1018

62,2 1528

62,2 1528

62,2 1528

1 ½''

A

cold water input

212

192

230

260

260

270

J

hot water outlet

884

1128

1235

1265

1265

1590

A

coil input

212

192

230

260

260

270

C

coil outlet

602

682

720

750

750

960

B

recirculation

472

532

570

600

600

610

F

electric resistance

400

400

400

400

400

400

H

total height

1070

1340

1480

1480

1480

1810

E

thermostat

818

1027

1070

1100

1100

1256 1590

K

thermometer

874

1138

1235

1265

1265

G

electrical resistance / socket

-

-

795

825

825

1011

D

diameter

Ø560

Ø560

Ø600

Ø600

Ø750

Ø750

Operation pressure / bar

10

10

10

10

10

10

Weight / kg

60

86

93

128

162

184

The electric resistance is an extra accessory and is being placed at the cleaning flange


Technical specification single coil floor standing boiler BLC-1 Material: steel sheet Welding: automatic metal welding Protection coating: high quality glass – enamel coating and protection anode Maximum working pressure: 10 bar Maximum working test pressure: 16 bar Maximum operating temperature: 95°C Insulation: polyurethane foam of 100mm thickness, density 40kg/m³ Coil: steel tube Maximum coil test pressure: 25 bar Electric heater: by order Flange: diameter Ø278mm

Volume L

750

1000

1500

Code

BLC-1-G

BLC-1-H

BLC-1-J

Coil S input / outlet

1''

1''

1''

Coil surface / m²

1,4 / 2,0

1,9 / 2,7

3

recirculation

Tap - anode

1'' 11/2''' 11/2''' 3/4''

1'' 11/2''' 11/2''' 3/4''

1'' 2 x 1 ½'' 2 x 1 ½'' 2 x 1 ½''

For connection to a boiler of S1 and water 10/45°C KW/L/h

50 1218

62 1534

122 1997

Cold water input Hot water outlet

A

cold water input

300

330

310

L N

hot water outlet

1630

1710

1965

B

sensor

535

530

510

A

coil input

300

330

310

C

coil outlet

970

1080

1160

E

recirculation

1405

1497

1477

F

electric resistance

450

470

450

H

total height

1990

2030

2310

E

thermometer

1560

1670

1477

K K

thermometer 2nd electric resistance socket

1405

1497

1210

M

anode

1435

1580

1640

D

diameter

Ø950

Ø1050

Ø1050

F

boiler cleaning hole

450

470

450

Operation pressure / bar

10

10

10

Weight / kg

190

230

540

The electric resistance is an extra accessory and is being placed at the cleaning flange


Technical specification double coil floor standing boiler BLC-2 Material: steel sheet Welding: automatic metal welding Protection coating: high quality glass – enamel coating and protection anode Maximum working pressure: 10 bar Maximum working test pressure: 16 bar Maximum operating temperature: 95°C Insulation: polyurethane foam of 50mm thickness, density 40kg/m³ Coil: steel tube Maximum coil test pressure: 25 bar Electric heater: by order Flange: diameter Ø170mm & Ø140

Volumen L

150

200

250

300

500

600

Code

BLC-2-A

BLC-2-B

BLC-2-C

BLC-2-D

BLC-2-E

BLC-2-F

Coil S1 & S2 input / outlet

1''

1''

1''

1''

1''

1''

Coil S1 & S2 surface / m²

0,53/0,72

0,78/0,99

0,78/0,99

0,99/1,55

0,99/1,55

1,55/1,55

Recirculation

3/4''(1/2'')

3/4''(1/2'')

3/4''(1/2'')

3/4''(1/2'')

1''

1''

Cold water input

1'' 1''

1'' 1''

1'' 1''

1'' 1''

1 ½''

Hot water outlet

1'' 1''

Anode - flange

Ø140

Ø140

Ø140

Ø140

Ø140

Ø140

For connection to a boiler with S1 in boiler with 90°C and water 10/45°C KW/L/h

16.3 254

19.7 338

19.7 340

22.5 394.2

22.5 394.2

42.5 977.5

For connection to a boiler with S2 in boiler with 90°C and water 10/45°C KW/L/h

18.2 450

22.5 552.8

22.5 542

31.25 542

31.25 767.5

35.7 1106.7

1 ½''

A

cold water input

212

192

230

260

260

270

N

hot water outlet

884

1128

1235

1265

1265

1590

C

coil S1 outlet

602

682

720

750

750

960

M

coil S2 outlet

884

1102

1170

1200

1200

1450

A

coil S1 input

212

192

230

260

260

270

J

coil S2 input

684

802

870

900

900

1062

K

recirculation

798

977

1070

1100

1100

1256

H

total height

1070

1340

1480

1480

1480

1810

E

sensor

631

742

795

825

825

1011

B

sensor

362

292

370

400

400

450 1256

L

thermostat

818

1027

1070

1100

1100

O

thermometer

874

1138

1235

1265

1265

1590

D

diameter

Ø560

Ø560

Ø600

Ø600

Ø750

Ø750

F

boiler cleaning hole

400

400

400

400

400

400

Operation pressure / bar

10

10

10

10

10

10

Weight / kg

69

100

107

149

175

202

The electric resistance is an extra accessory and is being placed at the cleaning flange


Technical specification double coil floor standing boiler BLC-2 Material: steel sheet Welding: automatic metal welding Protection coating: high quality glass – enamel coating and protection anode Maximum working pressure: 10 bar Maximum working test pressure: 16 bar Maximum operating temperature: 95°C Insulation: polyurethane foam of 100mm thickness, density 40kg/m³ Coil: steel tube Maximum coil test pressure: 25 bar Electric heater: by order Flange: diameter Ø278mm

Volume L

750

1000

1500

Code

BLC-2-G

BLC-2-H

BLC-2-J

Coil S1 & S2 input / outlet

1''

1''

1''

Coil S1 & S2 surface / m²

1,4 / 2,0

1,9 / 2,7

3

Recirculation

Tap - anode

1'' 11/2''' 11/2''' 3/4''

1'' 11/2''' 11/2''' 3/4''

1'' 2 x 1 ½'' 2 x 1 ½'' 2 x 1 ½''

For connection to a boiler S1 and water with 90°C and water 10/45°C KW/L/h

50 1218

62 1534

122 2997

For connection to a boiler S2 and water with 90°C and water 10/45°C KW/L/h

68 1564

84 2604

1965

Cold water input Hot water outlet

A

cold water input

300

330

310

M L

hot water outlet thermostat

1630

1710

1965

B

sensor

535

530

510

A

coil S1 input

300

330

310

C

coil S1 outlet

970

1080

1160

J

recirculation / thermometer

1405

1497

1477

F

electric resistance

450

470

450

N

anode

1768

1798

2062

K

thermometer

1405

1497

-

G

coil S2 input

1160

1220

1330

L K

coil S2 outlet

1560

1670

1780

H

total height

1990

2030

2310

D

diameter

Ø 950

Ø1050

Ø1050

E

sensor

1040

1150

1210

M

thermostat

-

-

1965

Operation pressure / bar

10

10

10

Weight / kg

215

300

590

The electric resistance is an extra accessory and is being placed at the cleaning flange


COMBO-BOILER BAK-1 with container and one coil 500 L 280 725 775 Ø450 Ø640 Ø840 865 965 1005 1690 1155 1310 1365 1365

A B C D1 D2 D3 E F G H J K L M

Typ Code

750 L 280 735 790 Ø650 Ø810 Ø1010 870 980 1015 1700 1165 1320 1370 1370

1000 L 280 865 950 Ø650 Ø810 Ø1010 985 1150 1195 1920 1350 1530 1590 1590

1350L 325 920 950 Ø800 Ø1000 Ø1200 970 1125 1170 2060 1325 1520 1575 1575

1600 L 340 925 950 Ø900 Ø1100 Ø1300 1200 1200 1250 2110 1425 1710 1710 1710

2000 L 395 935 855 Ø1100 Ø1200 Ø1400 1200 1105 1010 2088 1330 1460 1615 1615

500

750

1000

1350

1600

2000

BAK-1-B

BAK-1-C

BAK-1-D

BAK-1-E

BAK-1-F

BAK-1-G

492 16,2

744 19,8

882 22

1285 25

1539 27,2

1831 29,4

Coil surface / m²

2,2

2,7

3,0

3,4

3,7

4,0

Coil weight / kg

33,35

41,3

46

52,4

57,1

60,3

Volume / L Coil volume / L

Container weight / kg

2mm

3mm

2mm

3mm

3mm

3mm

3,5mm

4mm

3,5mm

4mm

4mm

56,5

84,5

48,4

117,6

132,8

176,6

206

234,8

233,2

267

302,2

Total weight / kg

123,2

151,2

161

200,2

224,8

263,9

293,3

322,1

328,4

362,2

403,8

Maximum operation pressure (coil) / bar Maximum operation temperature (coil) / °C Insulation (polyurethane) mm Container volume

16

16

16

16

16

16

160

160

160

160

160

160

100

100

100

100

100

100

120 L

170 L

170 L

170 L

170 L

170 L

The electric resistance is an extra accessory and is being placed at the cleaning flange


Accumulator boiler BAC-1 without coils

500 L 280 775 Ø450 Ø640 Ø840 965 1005 1690 1155 1310 1310 1365

A B C D1 D2 D3 E F G H J K L M

Typ Code

Insulation (polyurethane) mm

1000 L 280 950 Ø650 Ø810 Ø1010 1150 1195 1920 1350 1530 1530 1590

1350L 325 950 Ø800 Ø1000 Ø1200 1125 1170 2060 1325 1520 1520 1575

1600 L 340 950 Ø900 Ø1100 Ø1300 1200 1250 2110 1425 1710 1710 1710

2000 L 395 855 Ø1100 Ø1200 Ø1400 1105 1010 2088 1330 1460 1460 1615

500

750

1000

1350

1600

2000

BAC-1-B

BAC-1-C

BAC-1-D

BAC-1-E

BAC-1-F

BAC-1-G

490

742

880

1283

1537

1829

Volume

L Weight kg

750 L 280 790 Ø650 Ø810 Ø1010 980 1015 1700 1165 1320 1320 1370

2mm

3mm

2mm

3mm

3mm

3mm

3,5mm

4mm

3,5mm

4mm

4mm

56,5

84,5

78,4

117,6

132,8

176,6

206

234,8

233,2

267

302,2

100

100

100

100

The electric resistance is an extra accessory and is being placed at the cleaning flange

100

100


Accumulator boiler BAC-2 With one coil 500 L 280 725 775 Ø450 Ø640 Ø840 965 1005 1690 1155 1310 1310 1365

A B C D1 D2 D3 E F G H J K L M

Typ Code

Total weight / kg Total coil (exchanger) pressure / bar Total coil (exchanger) temperature / °C Insulation (polyutherane) / mm

1000 L 280 865 950 Ø650 Ø810 Ø1010 1150 1195 1920 1350 1530 1530 1590

1350L 325 920 950 Ø800 Ø1000 Ø1200 1125 1170 2060 1325 1520 1520 1575

1600 L 340 925 950 Ø900 Ø1100 Ø1300 1200 1250 2110 1425 1710 1710 1710

2000 L 395 395 855 Ø1100 Ø1200 Ø1400 1105 1010 2088 1330 1460 1460 1615

500

750

1000

1350

1600

2000

BAC-2-B

BAC-2-C

BAC-2-D

BAC-2-E

BAC-2-F

BAC-2-G

498 16,2

742 19,8

881 22

1284 25

1538 27,2

1830 29,4

2,2

2,7

3,0

3,4

3,7

4,0

33,35

41,3

46

52,4

57,1

60,3

Total volume / L Coil (exchanger) volume / L Coil (exchanger) surface / m² Coil (exchanger) weight / kg Accumulator weight / kg

750 L 280 735 790 Ø650 Ø810 Ø1010 980 1015 1700 1165 1320 1320 1370

2mm

3mm

2mm

3mm

3mm

3mm

3,5mm

4mm

3,5mm

4mm

4mm

56,5

84,5

78,4

117,6

132,8

176,6

206

234,8

233,2

267

302,2

89,85

117,85

119,7

158,9

178,8

229

258,4

287,2

290,3

324,1

362,5

16

16

16

16

16

16

160

160

160

160

160

160

100

100

100

100

100

100

The electric resistance is an extra accessory and is being placed at the cleaning flange


Accumulator boiler BAC-3 with two coil 500 L 280 725 775 Ø450 Ø640 Ø840 865 965 1005 1690 1155 1310 1360 1365

A B C D1 D2 D3 E F G H J K L M

Typ Code

Total weight / kg Total coil (exchanger) pressure / bar Total coil (exchanger) temperature / °C Insulation (polyutherane) mm

1000 L 280 865 950 Ø650 Ø810 Ø1010 985 1150 1195 1920 1350 1530 1570 1590

1350L 325 920 950 Ø800 Ø1000 Ø1200 970 1125 1170 2060 1325 1520 1560 1575

1600 L 340 925 950 Ø900 Ø1100 Ø1300 1200 1200 1250 2110 1425 1710 1605 1710

2000 L 395 395 855 Ø1100 Ø1200 Ø1400 1200 1105 1010 2088 1330 1460 1560 1615

500

750

1000

1350

1600

2000

BAC-3-B

BAC-3-C

BAC-3-D

BAC-3-E

BAC-3-F

BAC-3-G

498 16,2

744 19,8

882 22

1285 25

1539 27,2

1831 29,4

2,2 2,2

2,7 2,7

3,0 3,0

2,3 3,4

2,5 3,7

2,7 4,0

33,35 33,35

41,3 41,3

46 46

34,9 52,4

38,1 57,1

41,3 60,3

Total volume / L Coil (exchanger) volume / L Coil (exchanger) surface / m² Coil (exchanger) weight /kg Accumulator weight / kg

750 L 280 735 790 Ø650 Ø810 Ø1010 870 980 1015 1700 1165 1320 1370 1370

2mm

3mm

2mm

3mm

3mm

3mm

3,5mm

4mm

3,5mm

4mm

4mm

56,5

84,5

48,4

117,6

132,8

176,6

206

234,8

233,2

267

302,2

123,2

151,2

161

200,2

224,8

263,9

293,3

322,1

328,4

362,2

403,8

16

16

16

16

16

16

160

160

160

160

160

160

100

100

100

100

100

100

The electric resistance is an extra accessory and is being placed at the cleaning flange


Boiler reservoir MSG-1 & MSI-1 with two coil

A B

A - external diameter of the container B- diameter of the container

Q

C- overall hight D- hotwater retrace

D

E- heat exchanger input F- temperatur antenna G- circulator

E F G H I

P

H- heat exchanger output

C

I- heat exchanger input L- temperatur antenna M- heat exchanger output

L

N- coldwater forerun

M O

O- gasket 180 mm

N

P- space for electrical drag-typ Q- temperatur antenna

Lt

A

B

C

D

E

F

5/4"

1/2"

G

H

I

L

M

5/4"

5/4"

1/2"

5/4"

N

O

P

Q

S1

S2

lt/h-kW 80/60/45°C

6/4"

1/2"

S1

Kg

S2

200

560

500

1290

1060-1"

970

888

860-3/4"

765

675

560

265

155-1"

300

705

1035

0,8

1,5

520-21 980-40

105

300

560

500

1685

1450-1" 1345

1187

1132-3/4"

977

815

565

265

155-1"

300

925

1450

1

1,5

640-25 980-40

128

Boiler reservoir MSG made of steel and enamel Glass code volume MSG-1-A 200 L MSG-1-B 300 L

Boiler reservoir MSI made of stainless steel INOX code volume MSI-1-A 200 L MSI-1-B 300 L

Waterreservoir : • MSG1 and MSG2 made of steel DCP (2,5 cm thickness), with double enamel layer according to DIN 4753, baked at over 860ºC, for perfect corrosion protection

• MSG1 and MSG2 made of steel DCP (measurement 0,75m² x 2 / thickness 1,5 cm)

• MSI1 and MSI2 made of stainless steel INOX 316L (2 cm thickness)

• MSI1 and MSI2 made of stainless steel INOX (measurement 0,75m² x 2 / thickness 1,5 cm)

Insulation : • insulation made of ecologically friendly soft foam insulation with a thickness of 6cm at all types Cathodic protection : • magnesium anode exchanged periodicaly for perfect inner protection

Coat of heat exchanger :

External coat : • made of stainless steel AISI 304 (EN 10082-2), at all types

Electric parts : • temperatur regulator and safety temperaturrestrictor

All electrical parts have a CE - qualitymark in accordance with the regulations: EN 60335-1 und EN 60335-2-21, UNI EN 10025, UNI EN 287-1, DIN 4753-1, DIN 4753-2, DIN 4753-3, DIN 4753-4, DIN 4753-6. Electrical drag-typ is not encluded, but can be belated installed by an authorized installer. All measurements ar approximate statements. All technical changes reserved. The electric resistance is an extra accessory and is being placed at the cleaning flange


Solarkit Magicsun MST1 B

C

A

D

F

E G

J

A

safety valve exhaust pipe inside thread DIN 2000 / ISO 7, Rp ¾?

B

lockable ballcock (forerun)with safety valve and intigrated backpressure valve / external thread ISO 228, G1?

C

lockable ballcock (retrace) with intigrated metal made backpressure valve / external thread ISO 228, G1?

D

exhauster bottle with exhaust valve

E

recirculation pump WILO ST (25-6) solar model

F

manumeter - range 0-10 bar

G

wallmounting

H

equalisation vavlve SETTER Inline PF

J

thermometer - indicating range 0-160°C

K

hook up ADG - external thread ISO 228, G¾?

L

thermometer - indicating range 0-160°C

H K L

tecnical data max. operationthemperature (t B): - forerun (exhaustion side): 160°C - retrace (pumpside): 95°C max. operationpressure (p B): - to pB 8 bar possible - response pressure of built in saftly valve: 6 bar material: - exhaustpipe: steel varnished - fittingbody: brass - inner parts: rustproof steel, brass, synthetic, borosilikate (viewing glas) - O-ring gaskets: EPDM - flat gaskets: solar texture and high temperature proof - insulation: EPP - valve after DIN 2999 / ISO 7 and ISO 228 measuring accuracy ± 10% (of result) percolation textures: - water with common antirust and antifrost additions (indication index for texture consistence  = 2,3 mm²/s) - heaterwater and coolingwater

Solarregulator MSR1 Charmeg MP-DT Integra 3P characteristics

tecnical data temperature reading limits

0ºC bis 99ºC

main unit operation temperature

-20ºC... 60ºC

reading accuracy current rating (resistive load) probe number

± 2,5ºC 5A/250VAC /30VDC 3

• controls the solar medium pump and the burner • measures store and collector temperature from 0ºC to 99ºC • it has double thunder protection and galvanic insulation

probe cable length

MAX 30 m

• can be precisely adjusted to the desired temperature difference

protection degree (panel, unit)

Ip52, Ip20

• it has adjustable temperature hysteresis

firmware category

Class A

mains voltage

230 VAC 50 Hz

• can perform delayed operation for improved protection

power consumption

3 Watt

• it has intelligant anti-freeze protection

All measurements ar approximate statements. All technical changes reserved.


Pressureexpantioncontainer 18 L SDA1

• material is rustproof metal • fluid contend 18 L • for all complete systems

Flat roof boiler system MSFG and MSFI

system MSFG: • 2 x collectors EKA2 article no.

description

collectors

MSFG

Boiler SFG3 220L Glass

2 x 2m²

• flat roof installationset G3 • boiler SFG3 220 L Glass or SFI3 200 L INOX

system MSFI1:

• boiler with two heat exchangers article no.

description

collectors

MSFI

Boiler SFI3 200L INOX

2 x 2m²

• conection set for collectors and boiler

The boiler SFG has identical technical data as solar- hot wate reservoir MSG. The boiler SFI has identical technical data as solar- hot wate reservoir MSI. The boiler SFG and SFI will be deliverd with two heat exchangers. All measurements ar approximate statements. All technical changes reserved.


Declaration of warranty COLLECTORS

collector types: EKA1,5 - EKA2 and ホ必A2,5 ten (10) year warranty on collectorsfunction and durability of materials

Solar- hot water reservoirs and boilers all types of solar- hot water reservoirs and boilers: MSG1 / MSI1 / BAC1-3 / BLC1-2 BAC1 / MSFG / MSFI five (5) year warranty on function and durability of materials

WARRANTYCERTIFICATE AND INSPECTIONSRECORD for consumer (frontside) from dealer in U.S. warranty terms: 1.Warranty is valid from date of purchase, under the conditions of adviced instruction from the manufacturer and installation of authorized plumber. In case of missfunction of the product we oblige to insure a proper function, to replace defects if the problem results in a manufacturers fault. 2. A prolongation of the warranty is impossible after maintenance of repair. 3. As soon as the consumer notices a inproper function, he/she is obliged to interrupt the operation and to contact the plumber. The continued operation or the attemp to repair the product throuh not outherized persons, resultes in a expiration of the warranty, irrespective of the reason of the inproper operation.

for consumer (backside) from dealer in U.S. ILIOTEHNOTHERMIKI C.O warrantycertificate

INSPECTIONRECORD (cunsumer must sent this record to manifactur in order to activatewarranty )

confirmation of installer: The installation of the product was carried out by an authorized plumber and after adviced instruction from the manufacturer. The proper function of the product was notified. stamp of installer:

the installer:

5. To valid warranty claims, it is necessary to: a. the signiture and the stamp of the plumber installing the product b. mailing of the inspectionrecord to the manifacturer (minimum 15 days after purchase), and c. receipt as proof of purchase.

date . . . . . . . . . . . . . . . . . . . .

signature:

7. The collector types EKA1,5/EKA2/EKA2,5 have a ten (10) year warranty on collectorfunction and durability of materials. All collectors must be maintenanced once a year. 8. All solar- hot water reservoirs and boilers have a five (5) year warranty on function and durability of materials. On all solar- hot water reservoirs and boilers the magnesiumanode must be changed once a year. 9. All electrical parts as well as the circulationpump on MST1 and the solarregulator MSR1 have a one (1) year warranty. 10. The warranty of the pressureexpantioncontainer covers one (1) year. 11. For all complete solar systems the warranty of each paricular component valids. * EK1,5 - EK 2 - MK1,5 and MK 2 no warranty on concealer glas.*

ILIOTEHNOTHERMIKI C.O 46200 PARAMYTHIA-THESPROTIAS-GREECE

name/surename (client): adress (client): phone (client): dealer: adress (dealer): article number: serial-number: installations-date:

4. In case of unpredictable Events, such as for excample weathercatastrophies, the warranty is invalid. The warranty expires in case of any influence on the product by unouthorized persons, respectively a lack of maintenance.

6. The collector types *MK1,5/*MK2/MKA1,5/MKA2/MKA2,5/*EK1,5 und *EK 2 have a five (5) year warranty on collectorfunction and durability of materials. All collectors must be maintenanced once a year.

inspectionrecord

1. maintenance 2. maintenance number of invoice: . . . . . . . . . . . number of invoice: . . . . . . . . . . . date: . . . / . . . / . . . . . date: . . . / . . . / . . . . . signature:. . . . . . . . . . . . . . . . . . . signature:. . . . . . . . . . . . . . . . . . . 3. maintenance 4. maintenance number of invoice: . . . . . . . . . . . number of invoice: . . . . . . . . . . . date: . . . / . . . / . . . . . date: . . . / . . . / . . . . . signature:. . . . . . . . . . . . . . . . . . . signature:. . . . . . . . . . . . . . . . . . . 5. maintenance 6. maintenance number of invoice: . . . . . . . . . . . number of invoice: . . . . . . . . . . . date: . . . / . . . / . . . . . date: . . . / . . . / . . . . . signature:. . . . . . . . . . . . . . . . . . . signature:. . . . . . . . . . . . . . . . . . . 7. maintenance 8. maintenance number of invoice: . . . . . . . . . . . number of invoice: . . . . . . . . . . . date: . . . / . . . / . . . . . date: . . . / . . . / . . . . .

name/surename (consumer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . adress (consumer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...................................... phone (consumer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . adress (dealer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . phone (dealer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . article number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . serial number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

consumer confirmation: I hereby declare that the warrantyconditions are well-known, and the product is proper functional after installation.

date . . . / . . . / . . . . .

signature

plumber confirmation: I hereby declare that the product was installed appropriatly, and runs without problems after installation.

signature:. . . . . . . . . . . . . . . . . . . signature:. . . . . . . . . . . . . . . . . . . 9. maintenance 10. maintenance number of invoice: . . . . . . . . . . . number of invoice: . . . . . . . . . . . date: . . . / . . . / . . . . . date: . . . / . . . / . . . . . signature:. . . . . . . . . . . . . . . . . . . signature:. . . . . . . . . . . . . . . . . . .

date . . / . . / . . . .

signature / stamp


Exhellios Products 2009