Page 1

Power and control cables Extended ambient temperatures • FEP cables (-100°C to +205°C)


4-core version with PTFE core insulation and special colour code Info • EMC-compliant copper shielding


Product features

• Space and weight-saving installation due

• ÖLFLEX® HEAT 205 made of FEP

to small cable diameters

• Resistant to most highly aggressive

chemical media

• Low outgassing behaviour • Suitable for sensor technology due to good

electrical and mechanical properties

Application range • Conventional cables cannot be used in

industrial environments with very high temperatures, aggressive chemical media and limited space • Typical fields of application - Industrial furnace construction - Foundries - Chemical industry - Power plant engineering - Painting plant technology - Heating elements - Plastic processing - Wind turbine engineering • Sensor systems, e.g. fill level sensors

- Outstanding resistance against acids, solvents, lacquers, petrol, oils and many other chemical media - Flame-retardant - High dielectric strength and abrasion-resistance - Low water absorption - Resistant to microbes - Adhesion-free insulation materials - Weather- and ozone-resistant - Hydrophobic and dirt-repellent - High elongation capacity and tear resistance - Resistant against hydraulic fluids • Flame-retardant according to IEC 60332-12

Design • Fine-wire, silver-plated copper conductor • PTFE-based core insulation • Cores twisted together • Tin-plated copper braiding • Outer sheath: FEP-based, white

Number of Article Outer Copper index and mm² number cores (kg/km) per conductor diameter [mm] ÖLFLEX® HEAT 205 PTFE/FEP

Weight (kg/ km)

Technical data Classification ETIM 5.0 Class-ID: EC001578 ETIM 5.0 Class-Description: Flexible cable Core identification code blue, red, grey, black Conductor design Fine wire according to VDE 0295, class 5 / IEC 60228 class 5 from 0.5 mm² Minimum bending radius Occasional flexing: 15 x outer diameter Fixed installation: 4 x outer diameter Nominal voltage U0/U: 300/500 V Test voltage C/C: 2500 V C/S: 2000 V Protective conductor G = with GN-YE protective conductor X = without protective conductor Temperature range Fixed installation: -100°C to +205°C

Number of Article Outer Copper index and mm² number cores (kg/km) per conductor diameter [mm] 30016373 4 X 0.75 5.9 49.0

Weight (kg/ km) 78

Unless otherwise specified, the product values shown are nominal values. You can receive further values, such as tolerances, upon request if they available and have been released for publication. Please find our standard lengths at: Packaging: Ring ≤ 30 kg or ≤ 250 m, otherwise drum Please specify the preferred packaging (e.g. 1 x 500 m drum or 5 x 100 m rings) Photographs are not to scale and do not represent detailed images of the respective products.

Accessories • Kabelschere mit Doppelschneide refer to page [P305271] • SILVYN® AS refer to page [P1192] • SKINDICHT® SHV-M refer to page [P1015]

• SILVYN® EDU-AS refer to page [P1193] • KS 20 cable shears refer to page [P1249]

For current information see:


Power and control cables  
Power and control cables