30 YR ASPHALT SHINGLES TECHSHIELD

2X6 RAFTERS AT 16" O.C.

targeted

3,,+WSH[PU\T 5HSXSRVHG

CONTINUOUS INSULATION BAFFLE 5HFODLPHG6KLSODS6LGLQJ

2

2

6HDODQWVDGKHVLYHV'HWDLOV

4

2

2

6

6

(QYHORSH'HWDLOV 5DGLDQW%DUULHU:DOO

(QHUJ\(IÀFLHQF\

A1/2

1

HARDI PLANK SIDING

2

TYVEK HOUSE WRAP

6

CONTRACTOR TO NOTE:

1

HARDI PLANK SIDING

2

TYVEK HOUSE WRAP

3

7/16" OSB

4

1X1 FURRING STRIPS AT 16" O.C.

5

STRUCTURAL THERMALPLY

6

2X4 STUDS 16" O.C.

7

R-13 BATT INSULATION

8

1/2" GYP BD. AT INTERIOR

9

1/8" SCREEN AT BASE OF WALL

1

3

7/16" OSB

2

4

1X1 FURRING STRIPS AT 16" O.C.

4

5

STRUCTURAL THERMALPLY

6

2X4 STUDS 16" O.C.

Document Issue history: 04.04.2007 Client Review 1 09.17.2007 Client Review 2 10.01.2007 Client Review 3 11.12.2007 Snapshot Set 12.18.2007 Client Review 4 12.31.2007 Client Review 5 01.25.2008 Client Review 6 02.04.2008 Pricing 02.13.2008 Issue for Permit

7

R-13 BATT INSULATION

8

1/2" GYP BD. AT INTERIOR

9

1/8" SCREEN AT BASE OF WALL

1

1

1

1 2

2

4

1

4

2

A5 Cavity Wall

0HFKDQLFDO6\VWHPV

)UHVK$LU,QWDNH +HDW([FKDQJHU

+HDOWK\+RPH(QYLURQPHQW  1R92&SDLQWIRULQWHULRUV  (59 HQHUJ\UHFRYHU\YHQWLODWRU )UHVK$LU6XSSO\  1R92&ZRRGÁRRUÀQLVK  $PHULFDQ&OD\ZDOODQGFHLOLQJÀQLVK  $LUÀOWUDWLRQ6\VWHP

6

BUILDING ENVELOPE SCHEDULE

([SDQGLQJ)RDP,QVXODWLRQ *ULG7LH,QYHUWHU

0

6''

1'

SCALE: 1"

2'

= 1'-0"

15'-0"x14'-0"

AMERICAN STANDARD FREEDOM 95 FURNACE

R19 INSULATION

2

AMERICAN STANDARD ACCUCLEAN SYSTEM

4

AMERICAN STANDARD ACCUEXCHANGE ERV

'XDO)OXVK7RLLHWVW

5HSXUSRVH5HF\FOH &RQFUHWHFRQWDLQVÁ\DVK  /RFDODJJUHJDWHLQFRQFUHWH  /RFDOO\UHFODLPHG6KLSODSVLGLQJRQ(OHYDWLRQ  /RFDOO\UHF\FOHG:RRG)ORRULQJ  5HSXUSRVHGZRRGHQZLQHEDUUHOVIRUUDLQZDWHUVWRUDJH

POLYCELL INSULATION BARRIER AT ALL EXTERIOR STUD WALLS TYP. SCHED. BASE 2

FINISH FLOOR

WRAP SCREEN AT BOTTOM OF AIR SPACE

2

12

4 2

12

2

12

2

SPRINGHOUSE WATER SYSTEM

DUCT

Mechanical 204

12

2" INCH CONC. TOP RE: STRUCTURAL

2

4

2

1/2" CDX AT BOT. OF JOIST 2x6 TREX

4 2

4

)RRG&RRNLQJV\VWHPV

A4 Mechanical Room

tulane houston, Texas

3/4" CDX SUBFLOOR 3OXPELQJV\VWHPV

ford Y house

1x6 SYP #1 FLOORING

LOW VOLT. PANEL

:DWHU0DQDJHPHQW  PLQLPDOIRRWSULQWRISHUYLRXVDUHD  /RZ)ORZVLQNDQGVKRZHU  LQGLJHQRXVODQGVFDSHUHTXLULQJQRLUULJDWLRQ  5DLQZDWHUKDUYHVWLQJ

4

4

2

6RODU3DQHO

&DYLW\:DOO'HVLJQ 7DQNOHVVZDWHUKHDWHU 6RODUSDQHOVWLHGWRJULG 5DGLDQW%DUULHU+RXVH:UDS 3DVVLYH6RODU'HVLJQVLWHSODFHPHQW +LJK(IÀFLHQF\+9$&V\VWHP 5HÁHFWLYHURRÀQJIRUPLQLPL]LQJKHDWJDLQ ([SDQGLQJIRDPLQVXODWLRQ

6

(2) TWO FRAMING INSPECTIONS WILL BE REQUIRED.

PERFORATED HARDI SOFFIT METAL DRIP EDGE

       

2

/1

Construction Photos from Y house

2

A1

housing categories

1

R-30 BLOWN INSULATION IN ATTIC

2

GENERAL NOTES .LWFKHQFRPSRVWHU

R. K E

18

068

MI CH

A

EL

AS

AT

ER

ISSUED FOR PERMIT 22 APRIL 2008

ED A RC H LL

ST

THIS DOCUMENT AND THE DESIGN IDEAS INCORPORATED HEREIN ARE AN INSTRUMENT OF PROFESSIONAL SERVICE AND SOLE PROPERTY OF KELLER ARCHITECTURE AND IS NOT TO BE USED, IN WHOLE OR PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF KELLER ARCHITECTURE.

R TE

CT ITE

REGI S

WRAP ENTIRE HOUSE IN TYVEK CAULK EVERY POINT OF SIP CONNECTION WITH CAULK INSTALL ICE & WATER SHIELD UNDER STANDING SEAM METAL ROOF INSTALL DE-HUMIDIFIER WITH HUMIDITY CONTROL INSTALL EXHAUST VENT ON TIMER IN BATHROOMS INSTALL RADIANT BARRIER ON FURRING STRIPS

E O EX F T

Project:08006

09