Issuu on Google+

Wyatt Technology Corporation Launches the ViscoStar III  Online Viscometer for Polymer and Protein Characterization

1888 PressRelease ­ The Next Generation of Viscometers is launched with ViscoStar III by Wyatt Technology for  unmatched sensitivity, stability, and broadest range of solvents for macromolecular characterization. Houston, TX ­ Wyatt Technology, the world leader in instrumentation for absolute macromolecular  characterization, announces the launch of the third generation of intrinsic viscosity detectors: the ViscoStar  III. Used in conjunction with gel permeation chromatography (GPC) systems and multi­angle light scattering  (MALS) detectors, such as the company's DAWN and miniDAWN, the ViscoStar III can determine the molar  mass, size and conformation of all types of macromolecules, including polymers and proteins. The ViscoStar  III's sensitivity, dynamic range, resolution and stability surpass other GPC viscometers by at least an order of  magnitude­all while retaining robustness, ease­of­use and serviceability. Advanced Technology All contemporary online viscometers utilize a capillary bridge for highly sensitive measurement of  differential pressures arising from the differences in viscosity of solutions passing through the capillaries.  The four arms of the bridge must be perfectly balanced in order to make the most sensitive measurements;  however, even a well­balanced bridge is inherently susceptible to systematic noise due to dynamic pressure  pulses generated by the chromatography pump. At the heart of the ViscoStar III are two key advances for  overcoming these issues: thermal bridge tuning and complete impedance matching.  Thermal bridge tuning performs rapid, non­mechanical balancing of the capillary resistances to ensure  perfect bridge balance on every GPC run, even after material has accumulated on the capillary walls and  skewed the original bridge symmetry. Complete impedance matching goes beyond simple resistive bridge  balancing. It symmetrizes the dynamic properties of the capillary bridge and suppresses pump pulses by  100x. And the ViscoStar III does it without introducing the artificial band broadening that is used by other  online viscometers to smear out pump pulses at the cost of reduced chromatographic resolution. An  additional, proprietary software filter eliminates residual pump pulse levels without any loss of resolution.  The bridge­balancing, impedance matching and software filtering features were developed entirely in­house  by Wyatt's outstanding R&D staff.  "The ViscoStar III is a welcome addition to my macromolecular characterization lab" says Stepan Podzimek  of the University of Pardubice in the Czech Republic. Prof. Podzimek, one of the premier authorities on  polymer characterization, added "It far exceeds the sensitivity, resolution and chemical compatibility of all  other GPC viscometers I have tried, and sets a new standard for such instruments. It even works well with  older GPC systems that I would normally consider incompatible with online viscometry due to their  excessive pump pulsations. In combination with a HELEOS or TREOS, the ViscoStar III represents a  powerful tool for the thorough investigation of polymer conformation and branching and brings new 

capabilities to all laboratories involved in the characterization of synthetic and natural polymers." More innovation from Wyatt Technology Yet other "firsts" in the ViscoStar III include  • The only viscometer with a "dual" Peltier thermal control, which reduces signal drift by 50x relative to  competing instruments while allowing for both heating and cooling • pressure transducers with all­316L stainless steel wetted surfaces for reduced corrosion and highest  compatibility with the widest range of chromatographic solvents  • a system pressure sensor to detect capillary clogs and prevent transducer damage;  • a replaceable solvent filter that protects sensitive downstream components  • ready access to service all fluidic components. Protein applications "The ViscoStar III is a sensitive, stable and robust instrument. When combined with a DAWN or miniDAWN  MALS detector and size exclusion chromatography (SEC), we find it provides a more precise measurement  of the hydrodynamic radius of proteins especially at low concentrations, than the more commonly used  online dynamic light scattering (DLS)" stated Dr. Michelle Chen, Head of Analytical Services at Wyatt  Technology. "With sensitivity down to as little as 0.1 µg of 100 kDa polystyrene, or approximately 1 µg of  BSA, and a dynamic range of over 135,000:1, the ViscoStar III will add to our protein and peptide  characterization capabilities­in addition to enhancing our polymer analysis." A webinar describing the technological innovations, capabilities and applications of the ViscoStar III will be  broadcast on October 19, 2016. Visit­webinars.htmlfor details and to  register, or view on­demand at beginning October 28, 2016.  Additional information on the ViscoStar III may be found ###

Wyatt Technology Corporation Launches the ViscoStar III