Page 1

CAT3G1.1

ENCLOSURE SYSTEMS The Next Generation of Adaptive Enclosures for IT Environments

CABLING

MANAGEMENT

CABLE

POWER

FRAME

COOLING

TM

ENGINEERED PRODUCTS, LLC


IMS ENGINEERED PRODUCTS NEW DATA SERVER SERIES

04 3G Features Our Third Generation Server Cabinets have been designed and developed thru years of experience in the IT sector and feedback from real world applications. This section highlights the standard features that make this system adaptive to your specific IT environment and applications. The flexibility to adjust future demands is evident in the review of the internal and external components that define this enclosure system.

08 Pre-Configured Our Pre-Configured Series offers a selection of the most requested consoles that include frame, mounting channels, power panels, solid top panel, beveled screened front door, French screened rear door, levelers and hardware kit. Pre-configured consoles are available with or without side panels. Technical support for consoles is located on pages 18 and 19 of this catalog.

14 Power Choose from our specific group of power components that address today’s demands for power distribution, environmental and power monitoring - in both horizontal and vertical configurations. Twenty and thirty amp strips in 125v and 250v – with a variety of receptacle and plug models to choose from. UPS systems are also available. Consoles can ship with power and UPS systems mounted to your specified location.

17 Cooling This section addresses the IMS approach to Cooling – based on current trends in High Density Packaging and increased thermal loads. We provide specific thermal solutions for requirements of 7.5kW and up. Can provide solutions for your specific thermal requirements - standard or custom.

10 Build Your Own Sometimes pre-configured consoles can’t meet your SPECIFIC design requirements. This section lists all of the standard components to build a console to your exact enclosure specifications. It also features accessories and additional components for the pre-configured consoles. This section also includes material gauge specifications for all 3G standard components. Technical support for components is located on pages 18 and 19 of this catalog.

On-Line Catalog & Product Configurator Visit us on line at www.imsep.com for the latest updates and product releases. Use our Product Configurator to build a console in real-time. Get a drawing, BOM and 3D Model to support your exact design configuration.

IMS Engineered Products reserves the right to update/change products and make corrections without prior notice.

2


3G SERIES – ADAPTIVE ENCLOSURES FOR IT ENVIRONMENTS

MS Engineered Products introduces its third generation of enclosures for data applications. The convergence of the latest IT systems technologies – specifically the hardware - has created a demand for a new generation of enclosures that can effectively and efficiently house this equipment. Our new 3G enclosure systems address the most important requirements in today’s and tomorrow's IT environments. The internal enclosure environment must be self sustaining when it comes to power, thermal loads and cable management. The deployment of adaptive enclosures assures you that your system has the scalability and flexibility to change with the levels of hardware technology that drive Data Center Infrastructure Design.

I

Flexible Frame Design – designed with the ability to make optimal configuration adjustments possible within the actual physical environment of the enclosure system. Doors can mount within the frame perimeter or outside it, depending on what is required in the current build specifications. If the requirement changes, the enclosure can be re-configured – with only a few standard accessory adjustments for a completely different design application. Cable Management – Our 3G frame has options built in to effectively address ever-changing cable require-

ments. Frame features knock-outs in top section for internal cable runs. Optional vertical troughs assist in high density vertical drops that feed rack mount equipment and patch panels for data or networking. Top panels have multiple cable egress provisions for current and future design configurations. A variety of vertical and horizontal cable accessories create an internal cable management infra-structure that assures efficient cable management. Cooling – Aside from the generous 77% open pattern in our front and rear doors for optimal heat dissipation, IMS has a variety of passive and active cooling solutions for IT environments. We address the specific problems and provide highly effective solutions based on these requirements. Cool doors, server cabinet blowers, blanking panels and top panel fan trays for CRAC systems are all a part of our standard or custom solutions. Power – More advanced computing demands and the components that drive them, have increased power requirements. IMS can supply power distribution, UPS systems, smart power, environmental monitoring and custom power builds. Load Ratings – The Static load rating of the 3G Series cabinet is 3,200 lbs and the Dynamic load rating is 2,100 lbs.

“We gave it some thought so you don’t have to. Stronger by design.”

3


3G Features - Internal IMS Engineered Products has evolved the state of enclosures for IT hardware applications with its Third Generation of Adaptive Enclosures for IT Environments. We have taken the most requested features in the Industry and expanded on them – providing our customers with a flexible framing system that houses an ever changing internal IT environment that is safe and secure. This system and all of it’s components, have been designed and engineered from the ground up. CABLE KNOCKOUTS Frame features (4ea.) knockouts on top (sides) for inner bay cable passthru. Horizontal wiring troughs assist in cable support when using this feature.

MOUNTING CHANNELS Mounting channels are adjustable and feature a square (Universal) hole that accepts M6 mounting hardware. Channels feature a black finish with each rack unit (RU) marked in white. This allows quick location identification that speedsup equipment installation. EIA 310D compliant.

GROUNDING STUDS Frame weldment has 4 ground studs in base and 2 in top (1each in the top front & rear of frame).

FRAME PROFILE/DESIGN Frame incorporates an inner perimeter seal that optimizes airflow to servers rather than around equipment. Our new design aesthetic also gives structural support to the overall framing system.

Frame shown with power panel and power panel side struts on left side. Full length side struts shown on right side.

4


MULTI-FORM SIDE STRUTS New side strut design allows you to mount struts anywhere horizontally, front to rear, on each side of the enclosure. You can add additional struts based on your design. Flexi ring cable managers easily mount to struts for support of cable runs. CASTER BRACKETS

BASEPLATE Base plate is mounted to the inner frame flanges at the bottom of the enclosure. It provides optimal separation between interior and exterior environments - as the brush strips assist in keeping out dirt and dust while assisting in heat and pressure management.

Base of frame includes 4 caster brackets that encase the caster, protecting it from forklift blades that can damage cabinets in transportation to site deployment. Multi-formed caster brackets also enhance the base of the frame. Four leg levelers are included with each cabinet.

24” To 19” MOUNTING CHANNELS

POWER PANEL Power panels mount in rear of the frame and allow for the vertically mounting of most manufacturers power strips. Panel includes cable egress holes to assist in cable management. Power panel option provides 3" or 6" vertical panels which mounts at rear of frame. This results in minimal obstruction in rear cavity for thermal management.

Reduced width mounting channels are supplied with a black finish and white lettering for each RU. They feature an additional 2.5” on both sides of the square (Universal) hole pattern for additional cable management spacing. Grommets and dust covers are included for thermal containment when not in use. EIA 310D compliant.

DYNAMIC & STATIC LOAD RATING

Frame features a contemporary design aesthetic resulting in structurally significant load ratings. The following Static and Dynamic load ratings have been applied as tested and approved from an outside accredited testing lab. Static Load Rating – 3,200 lbs. Dynamic Load Rating – 2,100 lbs.

Frame load ratings are NOT dependent on side panels, doors or other components for structural support.

* Optional Features

5


3G Features - External The convergence of the latest IT technologies comes together in the ENCLOSURE – specifically the frame. Aesthetics now drive the current Data Centers as they need to be functional –yet contemporary and aesthetically pleasing. IMS has created the 3G Series to meet this demand. The profile of the frame is softer and the doors have a beveled design to reflect this trend. The external features shown on the next 2 pages cover the frame and expand it’s aesthetically pleasing design. CURVED SCREEN DOORS Curved doors provide a new radius design aesthetic that features a 77% open pattern for optimal heat dissipation. Doors have the same swing handle and reversable hinges as the beveled door.

REAR FRENCH DOORS French screened doors are standard on this series cabinet, to decrease door swing radius. This reduced swing radius, decreases the depth between rows, allowing additional cabinets to be deployed and increasing Data Center design efficiency. They feature a 77% open pattern for heat dissipation into “Hot” aisles. Swing handle, 3 point latch and keyed lock are included.

BEVELED DOOR HANDLE/HINGE Doors feature a 77% open pattern, providing optimal airflow and heat dissipation. Beveled doors are reversible (LH/RH) and feature easy on/off spring pin hinges. Swing handle, w/ keyed lock included.

77% VENT OPENING Doors feature a 77% open pattern, providing optimal airflow and heat dissipation. This ventilation design exceeds airflow requirements for major server manufacturers.

6


SIDE PANEL Panels function as baffle OR side panels and can be used between joined frames for thermal management. Easy-on and off side panels have a spring type finger latch, that slides to open or close, holding the panel in place. Locks are standard on all side panels. Locks can be ordered keyed alike or separately per the customers specific design requirements. (Keyed separately is an option and quoted upon request.)

TOP PANEL Top panel is solid and has 8 ea. (10 ea for 48" depth consoles) cable egress points with plastic grommets and cover plates located around the perimeter of the panel. This optimal egress design was configured to handle most cabling requirements.

* BLANKING PANEL Blanking panels are tool-less and cover the unused rack units in the front panel opening space of the server cabinet. This quick and easy accessory supplies 1/4 turn twist lock hardware with 16 ga. CRS enclosure panels for simple installation. Blanking panels support efficient use of air intake by servers to cool front to rear. When combined with server blowers they are extremely efficient and cost effective resources to manage cold air distribution to server cabinets.

* EXTERNAL CABLE TROUGH Vertical cable troughs are available in a 6" width with an overall depth of 10". Troughs run vertically on the side of the frame, and can be mounted front, rear or both. This accessory provides an optimal raceway for cable bundles and drops. Front doors provide easy access, while cut-outs in troughs supply pass thru egress for patch panels. Grommets are included for side to side cable egress holes and side panels are available to finish off end bays. * TROUGH

* CABLE WIRING SPACER KIT Cable Wiring Spacer Kit – Kit includes a full length bottom spacer bracket that accepts a full length cover panel with finger pull in center. System provides easy on/off access to cabling or power mounted between two cabinets. Cable troughs, spacer panels or cable wiring spacer kits are be used in pairs or mixed and matched ( 2 per side) to achieve necessary application/design requirements.

SPACER PANEL One spacer panel is required when one external vertical cable trough or cable wiring spacer kit is implemented in console design. Spacer panel can be used between two frames or at the end of a console row with a trough side panel. See page 19 in this catalog for application reference.

* Optional Features

7


PRE-CONFIGURED – without Side Panels Console Consist of: Frame with 2 pr of mounting channels, solid top panel, beveled front RH door with swing handle and keyed lock, French flush rear door with swing handle, 3 point latch and keyed lock, 2 ea. power panels with side struts, 4 ea. leg levelers, accessory hardware kit and frame joining hardware. Finish is black textured - unless other color choice is specified. See page 13 for standard color choices.

24" Overall Width – 19" Equipment Mounting 3G47U24-42C-NS 47RU 19" Panel Opening 3G47U24-45C-NS 47RU 19" Panel Opening 3G47U24-48C-NS 47RU 19" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G44U24-42C-NS 44RU 19" Panel Opening 3G44U24-45C-NS 44RU 19" Panel Opening 3G44U24-48C-NS 44RU 19" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G42U24-42C-NS 42RU 19" Panel Opening 3G42U24-45C-NS 42RU 19" Panel Opening 3G42U24-48C-NS 42RU 19" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

29" Overall Width – 24" to 19" Equipment Mounting 3G47U29-42C-NS 47RU 24" Panel Opening 3G47U29-45C-NS 47RU 24" Panel Opening 3G47U29-48C-NS 47RU 24" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G44U29-42C-NS 44RU 24" Panel Opening 3G44U29-45C-NS 44RU 24" Panel Opening 3G44U29-48C-NS 44RU 24" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G42U29-42C-NS 42RU 24" Panel Opening 3G42U29-45C-NS 42RU 24" Panel Opening 3G42U29-48C-NS 42RU 24" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

Please note the Width and Depth descriptions in part number reflect Exact overall dimensions. This incorporates overall frame width and depth of console with doors. The 42" depth console includes a 3" power panel (2 ea). The 45" and 48" consoles include a 6" power panel (2 ea).

Front View – Pre-configured console without side panels

IMS/AMCO is the perfect source for Equipment Distribution Area(EDA) cabinets for TIA-942 specification Data Centers. We can supply individual cabinets or room encompassing configurations to meet your exact design requirements. Our support team can assist through all aspects of your data program - from cabinet design configuration, power distribution, cable and cooling implementation and inventory management of completely integrated consoles ready to ship per your schedule. IMS Is THE source for Adaptive Enclosures for IT environments.

8

IMS can supply standard or custom consoles. If additional information or assistance is required contact your local sales representative or IMS directly at 847-391-8100

Rear View


PRE-CONFIGURED – with Side Panels Console Consist of: Frame with 2 pr of mounting channels, solid top panel, 2 ea. solid side panels with keyed lock, beveled front RH door with swing handle and keyed lock, French flush rear door with swing handle, 3 point latch and keyed lock, 2 ea. power panels with side struts, 4 ea. leg levelers, accessory hardware kit and frame joining hardware. Finish is black textured - unless other color choice is specified. See page 13 for standard color choices.

24" Overall Width – 19" Equipment Mounting 3G47U24-42C-S 3G47U24-45C-S 3G47U24-48C-S

47RU 19" Panel Opening 47RU 19" Panel Opening 47RU 19" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G44U24-42C-S 3G44U24-45C-S 3G44U24-48C-S

44RU 19" Panel Opening 44RU 19" Panel Opening 44RU 19" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G42U24-42C-S 3G42U24-45C-S 3G42U24-48C-S

42RU 19" Panel Opening 42RU 19" Panel Opening 42RU 19" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

29" Overall Width – 24" to 19" Equipment Mounting 3G47U29-42C-S 3G47U29-45C-S 3G47U29-48C-S

47RU 24" Panel Opening 47RU 24" Panel Opening 47RU 24" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G44U29-42C-S 3G44U29-45C-S 3G44U29-48C-S

44RU 24" Panel Opening 44RU 24" Panel Opening 44RU 24" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

3G42U29-42C-S 3G42U29-45C-S 3G42U29-48C-S

42RU 24" Panel Opening 42RU 24" Panel Opening 42RU 24" Panel Opening

42" Console Depth 45" Console Depth 48" Console Depth

Please note the Width and Depth descriptions in part number reflect Exact overall dimensions. This incorporates overall frame width and depth of console with doors. The 42" depth console includes a 3" power panel (2 ea). The 45" and 48" consoles include a 6" power panel (2 ea).

Front View – Pre-configured console with side panels

NEW Expanded Capacity Consoles. Frame features the 6" power panel in a TRUE 42" depth frame. Combined with the FLUSH screened front door this version of our pre-configured console provides an additional 3" of frame depth. This space can be used for increased power or cabling requirements in a compact footprint design. Reference flush door on page 18 of this catalog. Console Consists of: Frame, with 2 pair of mounting channels,solid top panel, 2 ea. solid side panels with keyed lock, FLUSH screened door w/swing handle and keyed lock, French flush screened door w/ swing handle, 3 point latch and keyed lock, two 6" power panels w/ side struts, 4 leg levelers, hardware kit and frame joining hardware.

24" Overall Width – 19" Equipment Mounting 3G42U24-42F-FF-S 42RU 19" Panel Opening 42" Console Depth 3G44U24-42F-FF-S 44RU 19" Panel Opening 42" Console Depth 3G47U24-42F-FF-S 47RU 19" Panel Opening 42" Console Depth

29" Overall Width – 24" to 19" Equipment Mounting

Front View

3G42U29-42F-FF-S 42RU 24" Panel Opening 42" Console Depth 3G44U29-42F-FF-S 44RU 24" Panel Opening 42" Console Depth 3G47U29-42F-FF-S 47RU 29" Panel Opening 42" Console Depth

9


Build Your Own Console – 24" (19" Panel Opening) - 29" (24" to 19" Panel Opening) For enclosure requirements where “off-the shelf” solutions are not possible – we provide you the ability to build your own console to your EXACT design. Why buy a cabinet that doesn't fit your needs. IMS can provide you with the components that you can mix and match to build to your specifications. The following pages list the standard frame components as well as the accessories needed to finish your console design. Mounting hardware included with each accessory or component. SIDE STRUTS - Material - 14 ga. CRS

FRAMES - Material - 14 ga. CRS 39" Frame Depth 42RU FR3G42U24 -39 44RU FR3G44U24 -39 47RU FR3G47U24 -39 42" Frame Depth 42RU FR3G42U24 -42 44RU FR3G44U24 -42 47RU FR3G47U24 -42 45" Frame Depth 42RU FR3G42U24 -45 44RU FR3G44U24 -45 47RU FR3G47U24 -45

Full Length Side Strut 39" Depth 42" Depth 45" Depth

AFS3G39 AFS3G42 AFS3G45

Power Panel Side Strut 39" Depth OFAS3G39 42" Depth OSFA3G42 45" Depth OSFA3G45

MOUNTING CHANNELS - Material - 14 ga. CRS

24" Frames - 19" Panel Opening

39" Frame Depth 42RU FR3G42U29 -39 44RU FR3G44U29 -39 47RU FR3G47U29 -39 42" Frame Depth 42RU FR3G42U29 -42 44RU FR3G44U29 -42 47RU FR3G47U29 -42 45" Frame Depth 42RU FR3G42U29 -45 44RU FR3G44U29 -45 47RU FR3G47U29 -45

MX Mounting Channels 42RU 44RU 47RU

MX3G42U MX3G44U MX3G47U

MXW Mounting Channels 42RU 44RU 47RU

MXW3G42U MXW3G44U MXW3G47U

POWER/ CABLE PANELS - Material - 14 ga. CRS 6" Wide

29" Frames - 24" Panel Opening - 19" equipment mounting Note: Frame component includes, weldment, 2 pair of mounting chassis, 4 leg levelers and hardware kit. To complete frame you must add 2 full length side struts per side, or if using power panel option, you must use 2 power panel side struts per panel. Reference image and note on page 4 for power panel and side strut applications.

10

42RU PP6-3G42U 44RU PP6-3G44U 47RU PP6-3G47U

3" Wide 42RU PP3-3G42U 44RU PP3-3G44U 47RU PP3-3G47U

Note: 3" wide panels only available on 39" frame depth consoles. 2 power panels side struts are required to mount this option


All internal components, except for side struts, power panels and baseplates are supplied with a black textured finish as standard. Other color options available upon request. VENTED DOORS - Material - 18 ga. CRS

Beveled (w/Handle & Lock) 24" Frame Width 42RU BVD3G42U24 44RU BVD3G44U24 47RU BVD3G47U24 29" Frame Width 42RU BVD3G42U29 44RU BVD3G44U29 47RU BVD3G47U29

Flush Screen* (w/Handle & Lock)

Flush French (w/Handle,Lock & 3 Point Latching)

24" Frame Width

24" Frame Width 42RU FFSD3G42U24 44RU FFSD3G44U24 47RU FFSD3G47U24

42RU FSD3G42U24 44RU FSD3G44U24 47RU FSD3G47U24

29" Frame Width

29" Frame Width

42RU FFSD3G42U29 44RU FFSD3G44U29 47RU FFSD3G47U29

42RU FSD3G42U29 44RU FSD3G44U29 47RU FSD3G47U29

CURVED DOORS - Material - 18 ga. CRS

SIDE PANEL - Material - 18 ga. CRS With Lock 39" Frame Depth 42RU SP3G42-39-K 44RU SP3G44-39-K 47RU SP3G47-39-K

Curved Screen (w/Handle & Lock)

42" Frame Depth

24" Frame Width

42RU SP3G42-42-K 44RU SP3G44-42-K 47RU SP3G47-42-K

42RU CVD3G42U24 44RU CVD3G44U24 47RU CVD3G47U24 29" Frame Width

45" Frame Depth

42RU CVD3G42U29 44RU CVD3G44U29 47RU CVD3G47U29

42RU SP3G42-45-K 44RU SP3G44-45-K 47RU SP3G47-45-K

* Note: Flush screen doors are available as LH or RH. Specify -L or -R at the end of the part number.

TROUGH SIDE PANEL - Material - 18 ga. CRS

TROUGH SPACER - Material - 14 ga. CRS

CABLE WIRING SPACER KIT - Material - 14 ga. & 18 ga. CRS

39" Frame Depth 42RU TSP3G42U-39 44RU TSP3G44U-39 47RU TSP3G47U-39 42" Frame Depth 42RU TSP3G42U-42 44RU TSP3G44U-42 47RU TSP3G47U-42

6" Panel 42RU TS3G42U-6 44RU TS3G44U-6 47RU TS3G47U-6

6" Spacer Kit 42RU CWSK3G42U-6 44RU CWSK3G44U-6 47RU CWSK3G47U-6

45" Frame Depth 42RU TSP3G42U-45 44RU TSP3G44U-45 47RU TSP3G47U-45

11


Build Your Own Console – 24" (19" Panel Opening) - 29" (24" to 19" Panel Opening) TOP PANELS - Material - 14 ga. CRS

BASEPLATE - Material - 16 ga. CRS

24" Frame Width 39 D BPLT3G24-39 42 D BPLT3G24-42 45 D BPLT3G24-45 29" Frame Width 39 D BPLT3G29-39 42 D BPLT3G29-42 45 D BPLT3G29-45

Solid 24" Frame Width 39 D TPS3G24-39 42 D TPS3G24-42 45 D TPS3G24-45

24" Frame Width

24" Frame Width 39 D TPV3G24-39 42 D TPV3G24-42 45 D TPV3G24-45

29" Frame Width 39 D TPS3G29-39 42 D TPS3G29-42 45 D TPS3G29-45

Fan - BTA4

Vented

39 D TPF3G24-39 42 D TPF3G24-42 45 D TPF3G24-45

BPT3G24-1U BPT3G24-2U BPT3G24-3U BPT3G24-4U BPT3G24-8U

29" Frame Width

29" Frame Width 39 D TPV3G29-39 42 D TPV3G29-42 45 D TPV3G29-45

BLANKING PANELS - Material - 16 ga. CRS - 19" mounting

39 D TPF3G29-39 42 D TPF3G29-42 45 D TPF3G29-45

SCREENED FAN PANEL - Material - 16 ga. CRS

VERTICAL CABLE TROUGH - Material - 14 ga Body/18 ga. Doors 24" Frame Width SFP3G24 -2 SFP3G24 -4

6" Wide

24" Frame Width

CTE3G42-6 CTE3G44-6 CTE3G47-6

SFP3G29 -2 SFP3G29-4

-2 at the end of part number is for - 200CFM -4 at the end of part number is for - 400CFM Note: For use with beveled door. INTERNAL (Horizontal) CABLE TROUGH - Material - 14 ga. CRS

CABLE RING KIT - Material - Molded Plastic

24" Frame Width

29" Frame Width

HK-CR1

IHCT3G24

IHCT3G29

Kit includes 10ea. 3.42" (W) x 1.38" (D) Tool-less Cable Rings

12

CABLE LACING STRIP - Material - 14 ga. CRS

Shown with optional Cable Rings 5" Wide 42RU CBLS3G42U 44RU CBLS3G44U 47RU CBLS3G47U


POWER – Distribution & Environmental Monitoring The ability to monitor and control your system from remote locations 24/7/365 anywhere in the world, creates a greater sense of comfort for today’s IT managers. Power distribution, temperature, humidity, air flow, water sensors and video recording, are all features that are now available with IMS power distribution and environmental monitoring systems. Sensors (internal or external) within the enclosure create a synergistic approach that provides pinpoint assessment of your systems real-time performance. This system features a “plug & play solution” so no software is required, as well as a web based interface to provide remote accessibility. Protected password for administrative and view only access.

Self-Contained Operation Eliminates need to download additional software Connects to optional Remote Display (PDD) and Web Camera

Simple Installation “Plug & Play” solution; no client software Viewable via web browser Automatic time set via internet time servers

Ease of Expansion External sensors may be added at any time Remote temperature sensor Remote temperature, airflow and humidity sensor Door position sensor Water sensor Web enabled camera External sensors are automatically discovered

Conveniently Accessed Diagnostic Data User defined graphing variables Log data available for export to XML Log data available real time via SNMP PDA and WAP screen formats User defined alarm thresholds Simultaneous access by multiple users

Data and Communications Protocols & Applications The following are supported: • DHCP • HTML • HTTP • ICMP • SNMP • Static IP • SMTP • TCP/IP • • Telnet • UDP • XML •

Timely Monitoring and Alarm Notification Audible alarm via display module – PDD SNMP traps for alarm and alarm clear E-mail notification Any combination of the above

Protected Access

IMS Master PDE

Administrative password View only password

3

1

4

2

5 Internal Environmental Sensors Temperature: Humidity: Air Flow: Sound Level: Light Level:

-67F to 175F, +/- .9F 0-100%, +/- 5% 0-100, relative 0-100, relative 0-100, relative

Internal Power Sensors Volts RMS: Amps RMS:

External Sensor Connection Ports Four RJ11 Jacks – Connect up to 16 Remote Sensors per PDE unit 1 Three I/O Ports, 0-5 vdc analog or contact closure 2 Remote Display Connection Jack

14

Ethernet Connection Jack

4

6 7 8 80-280 VAC 0-30 A

Software Reset Button Activity Indicator Idle Indicator

6

7

Power On Indicator

3

8

5


All Power Distribution units listed on this page have the monitoring features shown on page 14. The PDD Unit option is for an external monitor that can mount outside of the of frame. See image at the bottom of this page

Horizontal Power Distribution, Environmental/Power Monitoring - 20 Amp - 125, 250 or 125/250 Volt – 10/12 Outlets – IEC & NEMA* Part Number PDE1910-20-125-NB10 PDE1910-20-250-NB10 PDE1912-20-DV-NBNC

Amps 20 20 20

Volts 125 250 125/250

Receptacle 5-20R 6-20R C-13

Qty. 10 10 12

Plug 5-20P Straight Blade 6-20P Straight Blade C-20 Inlet *

Circuit Breaker No No No

UL Designation

Remote Display

UL &c-UL Listed 60950 UL &c-UL Listed 60950 UL &c-UL Listed 60950

Optional Optional Optional

Vertical Power Distribution, Environmental and Power Monitoring - 30 Amp - 125 or 250 Volt – 24/30 Outlets – NEMA Part Number PDE6624-30-125-2010 PDE6630-30-250-2010 PDE6624-30-250-2010

Amps

Volts

30 30 30

125 250 250

Receptacle 5-20R 6-20R 6-20R

Plug

Circuit Breaker

UL Designation

Remote Display

L5-30P Twist Lock L6-20P Twist Lock L6-30P Twist Lock

Yes Yes Yes

UL &c-UL Listed 60950 UL &c-UL Listed 60950 UL &c-UL Listed 60950

Optional Optional Optional

Qty. 24 30 24

Vertical Power Distribution, Environmental and Power Monitoring - 30 Amp - 250 Volt – 24 Outlets – IEC Part Number PDS6630-30-250-2010

Amps

Volts

30

250

Receptacle C-13

Circuit Breaker

UL Designation

Remote Display

L6-30P Twist Lock

Yes

UL &c-UL Listed 60950

Optional

Vertical Power Distribution, Environmental and Power Monitoring - 20 Amp - 250 Volt – 20 Outlets – IEC Part Number PDS6620-20-250-NB10

*

Amps

Volts

20

250

Receptacle C-13

*

Plug

Qty. 24

*

*

Qty.

Plug

Circuit Breaker

UL Designation

Remote Display

20

6-20P

No

UL &c-UL Listed 60950

Optional

All Units come Standard with 10ft. Cord – Except PDE1912-20-DV-NBNC which has a C-20 inlet

POWER – Accessories IMS provides a complete line of sensors, displays and web cams for it's Environmental Monitoring Series. Specific information of each item is available by contacting IMS direct. Remote Sensors – Remote Temperature, Airflow & Humidity Sensor – PDD Remote Temperature Sensor Door Position Sensor Water Sensor Web Enabled Camera

Remote Display (visual display & audible alarm)

15


POWER – Distribution Today’s Data Centers demand higher power distribution and management. New generations of solutions are available based on current and future requirements. IMS can provide you with a power solution that is efficient and cost effective. Your cabinet can be delivered with the power strips installed. Contact us today to determine the power strip that best fits your requirements. Standard or custom, we supply it all.

Horizontal Power Distribution – 30 Amp - 250 Volt – 10 Outlets – IEC – 10ft. Cord Part Number

Amps

Volts

Receptacle

Qty.

Plug

PDU1910-30-250-1510

30

250

IEC320 (C13)

10

L6-30P Twist Lock

PDU1910-30-250-1510M

30

250

IEC320 (C13)

10

L6-30P Twist Lock

Circuit Breaker

UL Designation

Power Meter

Yes

UL &c-UL Listed 1950

N

Yes

UL &c-UL Listed 1950

Y

UL Designation

Power Meter

Horizontal Power Distribution – 30 Amp - 250 Volt – 12 Outlets – NEMA – 10ft. Cord Part Number PDU1912-30-125-2010M

Amps

Volts

Receptacle

Qty.

30

125

5-20R

12

Plug L5-30P Twist Lock

Circuit Breaker Yes

UL &c-UL Listed 60950

Y

Vertical Power Distribution – 30 Amp - 250 Volt – 24 Outlets – IEC – 10ft. Cord Part Number PDU6624-30-250-1510M

Amps

Volts

Receptacle

Qty.

Plug

30

250

IEC320 (C13)

24

L6-30P Twist Lock

Circuit Breaker Yes

UL Designation

Power Meter

UL &c-UL Listed 1950

Y

Vertical Power Distribution – Dual Circuit - 30 Amp - 125 or 250 Volt – 24 Outlets – NEMA – 10ft. Cord Part Number

Amps

Volts

Receptacle

PDU6624-30-125-2010D

30

125

5-20R

PDU6624-30-250-2010D

30

250

6-20R

Plug

Circuit Breaker

UL Designation

Power Meter

24

L5-30P Twist Lock

Yes

UL &c-UL Listed 60950

Option

24

L6-30P Twist Lock

Yes

UL &c-UL Listed 60950

Option

Qty.

Vertical Power Distribution – 3 Phase 60 Amp - 250 Volt – 45 Outlets – IEC - 10ft. Cord Part Number PDU7045-60-250-2010

Amps

Volts

60

250

Receptacle C-13

Qty. 45

Plug

Circuit Breaker

UL Designation

Power Meter

IEC 60309

Yes

UL &c-UL Listed 60950

N

UPS Systems – Single Phase Power Products for Network and IT Environments Line Interactive or True ON-LINE double conversion technology IMS understands the need for facilities and data centers to have proper power protection for their computing environments. We have teamed up with one of the largest suppliers of UPS systems – MGE, to supply you with the a safe, secure enclosure system that ships with the UPS installed. This saves you both time and money. Speak with one of our power consultants today and let us configure a UPS solution. Features and Benefits: • SNMP and WEB access to gathered data • Software included with every UPS • Rack or Tower versions available • IT managers can restart locked equipment by remotely switching ON/OFF individual Power share outlets on the UPS. • Wide input voltage range allows end users to adjust the input voltage window to reduce the number of transfers to battery power while maintaining constant output voltage •

16


Cooling – Solutions Today’s trend in blade servers and densely packaged enclosures creates larger demands in power distribution and cabling. The sum of all these variables is the unwanted, damaging effects of higher heat loads – which can significantly reduce computing performance. (Slower computing speeds and equipment failure). IMS addresses these concerns by supplying solutions specific to the cooling requirement. We provide standard and custom solutions for Enclosure heat dissipation.

HOT/COLD AISLE DESIGN Level One – Passive Passive approach to heat dissipation for server cabinets • Beveled Screened Front Door (77% open pattern) • French Screened Rear Door (77% open pattern) • Blanking Panels for unused RU in front panel opening. Level Two – Enhanced Passive Enhanced approach to heat dissipation for server cabinets • Beveled Screened Front Door (77% open pattern) • French Screened Rear Door (77% open pattern) • Server Cabinet Blower (15Degree drop in cabinet temp) • Blanking Panels for unused RU in front panel opening. Note: Option of 200 or 400 cfm Fan Panels for Rear Doors

Our research – conducted with outside thermal engineering resources have provided us with data necessary to develop our Level 3 - Active Thermal Design. High density thermal solutions require that the additional heat be dissipated thru the rear of the enclosure, by either a fan door or rooftop fan tray. The fan tray works by exhausting the hot air from the rear of the enclosure into the CRAC unit for re-conditioning and distribution, while the fan door exhausts the hot air directly into the “Hot” aisle. We work with Case 1 – Lower Installation with Full Heat Load our customers so that their consoles are thermally efficient – as single bay consoles or room encompassing systems.

CRAC Duct Design Front blanking panel

Rear door with two upper fan trays & exhaust duct

5U @ 2.5KW

Level Three – Active Active approach to heat dissipation for server cabinets • Beveled Screened Front Door (77% open pattern) • Solid Rear Door (77% open pattern) • Roof Fan Tray w/ Exhaust Duct • Blanking Panels for unused RU in front panel opening.

7U @ 3.5KW

Note: This version is also available with exhaust into Hot Aisle Contact IMS/AMCO DIRECT for information and available versions.

7U @ 3.5KW 7U @ 3.5KW

Airflow Plot – Center of the Rack

Temperature Plot – Center of the Rack

System airflow = 940 CFM @ 0.11 inH2O

Speed (ft/min) > 1500 Very low upper recirculation

1125

Low temperature stratification

Temperature (degC) Uniform airflow

750

Inlet temperature rise above external ambient

> 60 0.4 C

5U

375

0.4 C

7U

<0

0.4 C

7U

0.9 C

7U

51.25

Minor airflow leakage below the rack

42.5

33.75

< 25

17


3G – Technical Reference The following two pages provide dimensional references for the 3G Series Consoles as well as application illustrations for the trough components. For additional technical information contact IMS direct. Note: For Frame dimension without Beveled door see Dimension “E” in Chart.

24" Part No. 3G42U24-42 3G42U24-45 3G42U24-48 3G44U24-42 3G44U24-45 3G44U24-48 3G47U24-42 3G47U24-45 3G47U24-48

TOP VIEW

24.00 or 29.00

E

D i mensi ons

29" Part No. 3G42U29-42 3G42U29-45 3G42U29-48 3G44U29-42 3G44U29-45 3G44U29-48 3G47U29-42 3G47U29-45 3G47U29-48

A

B

C

D

E

F

78.56" 78.56" 78.56" 82.06" 82.06" 82.06" 87.31" 87.31" 87.31"

73.88" 73.88" 73.88" 77.38" 77.38" 77.38" 82.63" 82.63" 82.63"

69.56" 69.56" 69.56" 73.06" 73.06" 73.06" 78.31" 78.31" 78.31"

7.79" 10.79" 13.79" 7.79" 10.79" 13.79" 7.79" 10.79" 13.79"

39.00" 42.00" 45.00" 39.00" 42.00" 45.00" 39.00" 42.00" 45.00"

42.00" 45.00" 48.00" 42.00" 45.00" 48.00" 42.00" 45.00" 48.00"

F 3.0 X 6.5 KNOCK-OUT HOLES

1.813

4.50

C

A

B

4.50

.88 Min.

2.875 D

29.21

2.00

FRONT VIEW

SIDE VIEW

REAR VIEW

CONSOLE ASSY

Note: 3" Power Panel is included for 42" depth consoles. 6" included for 45" & 48" depth consoles

DOORS - Material - 18 ga. CRS — Perforated area .25 Honeycomb, 77% Open

A

A

B

B

Part No. BVD3G42U24 BVD3G42U29 BVD3G44U24 BVD3G44U29 BVD3G47U24 BVD3G47U29

18

B

2.75

Dim ens io n s A

B

75.81" 75.81" 79.31" 79.31" 84.56" 84.56"

22.57" 27.57" 22.57" 27.57" 22.57" 27.57"

B

Part No. FSD3G42U24 FSD3G42U29 FSD3G44U24 FSD3G44U29 FSD3G47U24 FSD3G47U29

Flush French Door

Dimensions A

B

73.50" 73.50" 77.00" 77.00" 82.25" 82.25"

20.28" 25.28" 20.28" 25.28" 20.28" 25.28"

3.00

.56

.56

Flush Door

Beveled Door

A

A

Part No.

D i mensi ons A

FFSD3G42U24 FFSD3G42U29 FFSD3G44U24 FFSD3G44U29 FFSD3G47U24 FFSD3G47U29

73.50" 73.50" 77.00" 77.00" 82.25" 82.25"

Curved Door Part No.

B 20.18" 25.18" 20.18" 25.18" 20.18" 25.18"

CVD3G42U24 CVD3G42U29 CVD3G44U24 CVD3G44U29 CVD3G47U24 CVD3G47U29

D i mensions A

B

75.81" 75.81" 79.31" 79.31" 84.56" 84.56"

22.57" 27.57" 22.57" 27.57" 22.57" 27.57"


SIDE PANELS - Material - 18 ga. CRS

Part No.

Di mensi ons A

SP3G42-39-K SP3G44-39-K SP3G47-39-K SP3G42-42-K SP3G44-42-K SP3G47-42-K SP3G42-45-K SP3G44-45-K SP3G47-45-K

A

69.46" 72.96" 78.21" 69.46" 72.96" 78.21" 69.46" 72.96" 78.21"

TOP PANELS - Material - 16 ga. CRS Cable egress holes are 3.00" X 6.50" and include grommet & dust covers.

B 33.31" 33.31" 33.31" 36.31" 36.31" 36.31" 39.31" 39.31" 39.31"

39" & 42" Frame Depth 24" - 20.75" 29" - 25.75"

39" - 33.25" 42" - 36.25" B

TROUGH SYSTEMS - Material - 14 & 18 ga. CRS Vertical troughs can be used in any combination with trough spacers or cable wiring spacer kit. They can be used between bays or at the end of console rows. Side panels also available.

Cable Trough & Spacer Kit

Double Cable Trough 39" - 33.25" 42" - 36.25"

45" Frame Depth 24" - 20.75" 29" - 25.75"

45" - 39.25"

Double Cable Trough & End Panel

Cable Trough with Spacer & End Panel

45" - 39.25"

19


WARRANTY & POLICIES A. Choice of Method of Shipment

Limited Warranty

Unless otherwise specified, IMS Engineered Products frames are shipped as individual modules per ISTA packaging certification with single width components assembled on the frame. Upon request, console arrangements will be completely assembled at the factory and shipped like furniture, via van, at no additional charge for assembly. Console arrangements may also be crated for shipment. Crating charges will be quoted for each such order, as console arrangements vary.

IMS Engineered Products will repair or replace enclosures, accessories, and components manufactured by IMS Engineered Products that are proven to be defective in material or factory workmanship under normal use during the Period of this Warranty.

B. Design Changes

1) Failure in whole or part resulting from misuse, alteration, excessive temperature, excessive humidity, corrosive environment, or lack of maintenance. 2. Any materials or components used or manufactured pursuant to the purchaser’s specifications. 3) Deterioration due to normal use and exposure. 4) Items ordered in error or not required.

To allow continued progress, improvement, and adaptability in an advancing industry, IMS Engineered Products reserves the right to make product changes as deemed necessary.

C. Price Discounts

Warranty Period One year from date of purchase.

This warranty does not cover

Purchase orders cannot be combined for discount advantages.

Power/Accessories

D. Proprietary Rights

Warranty Repair

The catalog and drawings contain information deemed proprietary to IMS Engineered Products and are to be used only for the purposes for which they are submitted and, further, shall not be copied in whole or in part without the prior written consent of IMS Engineered Products.

Purchaser shall obtain controlled authorization number before returning any items alleged to be defective to IMS Engineered Products.

E. Cancellation & Return Cancellation and return charges begin at 40% with a minimum of $50.00, depending on the nature of the order and the extent to which it has been processed. All returns have a 30 day – upon receipt – time limit. Returns must be freight prepaid and not made without the prior written approval of IMS Engineered Products.

F. Terms All quotations, order confirmations, published prices, and discounts based on delivery F.O.B. IMS Engineered Products, 1 Innovation Drive, Des Plaines, IL freight collect. Invoice payment terms—net 30 days.

Warranty as specified by manufacturer.

Inspection IMS Engineered Products shall have the right to inspect any and all allegedly defective items on-site at purchaser’s convenience.

Disclaimer of Consequential Damages and Limitations of Implied Warranty IMS Engineered Products disclaims any responsibility for loss of time or use of parts or equipment wherein IMS Engineered Products enclosures, components, or accessories are used, transportation or any other incidental or consequential damage; and any implied Warranties including the implied Warranty of merchantability and fitness for intended use are limited to the duration of this written Warranty.

G. Sales Representation Experienced factory sales representatives in all principle cities of the U.S.A., Canada and Mexico. Ask for sales representative listing. IMS Engineered Products equipment is thoroughly inspected prior to shipment. NO returns of damaged equipment will be accepted without prior written approval of IMS Engineered Products.

TM

ENGINEERED PRODUCTS, LLC

1 Innovation Drive, Des Plaines, IL 60016 • Ph-847-391-8100 • Fax-847-391-8354 • www. imsep.com •

KSP10081K

3G Catalog  