Page 1

Vandal Resistant 4 Wire Terminals. Series JNT162. Analog station : Doors, lifts , help points, prisons suitable for centrals GE50, GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas where a high level of security is required.

JNT162

Analog 4-Wire Wall Station Substation for flush/surface mounting, for areas where a high level of security is required (reliability, vandal proof, ...). Line saving, secure 4-wire-technology. with programmable call button, electret microphone and loudspeaker. Metal housing, resistant against dust and spray water. Front panel made of 2mm stainless steel,

12 345 6 7

JNT 162

with poke protection and special screws for protection against vandalism. Various call buttons available for adaption to the application. Also includes one relay output. Fitting surface mount boxes are available, outdoor JNTX61U, indoor JNTX61UI-1, JNTX61UI-2

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsv채gen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se


Vandal Resistant 4 Wire Terminals. Series JNT162. Analog station : Doors, lifts , help points, prisons suitable for centrals GE50, GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas where a high level of security is required.

JNT162 Out/In door unit JNT162

Out/In door unit JNT162-3

Flush mount box for JNT 162 E14 362 00

12 345 6 7

For surface or flush mounting, with 1programmable call button (2 additional call buttons optional). Front panel made of 2 mm stainless steel. Measurements: H:180mm, W:90mm, D:25mm Benefits: Loudspeaker, microphone and pushbutton are vandal-proof. Color: stainless steel, weight 363g (JNT162), 407g (JNT162-3 Relay for external indication, one output (LED) max 20 mA PCB coated for extreme conditions . Extent of supply 4 screws for mount in box.

H 164, W 75, D 56, weight 136g Measurements inside box

Intercom station Indoor unit IP44 JNT162 + JNTX61UI-1

Indoor unit IP44 JNT162-3 + JNTX61UI-1

Wall mount box JNTX61UI-1

Surface mount box JNTX61UI-1 Surface mount box for use indoor areas. Made of 1,0 mm stainless steel. Measurements: W 109mm, H 182mm, D 35mm. Weight 81g Color: Stainless steel

Metal housing, resistant against dust and water (protection category IP 44).

Indoor mount

Outdoor unit IP54 JNT162 + JNTX61U

Outdoor unit IP54 JNT162-3 + JNTX61U

Wall mount box JNTX61U

Surface mount box JNTX61U Surface mount box with rain shield for use in outdoor areas. Made of 1,0 mm stainless steel. Measurements: W 93mm, H 186mm, D 49mm (minimum depth) 68mm (maximum depth) Weight 296g Color: stainless steel Extent of supply Rain shield (covers microphone)

Rain shield (covers microphone) JNT161-N

Outdoor mount

Extent of supply 1 Cablegland

Surface box JNTX61U Is available with built-in tamper switch JNTX61-T

Metal housing, resistant against dust and spray water (protection category IP 54).

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsv채gen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se


Vandal Resistant 4 Wire Terminals. Series JNT162. Analog station : Doors, lifts , help points, prisons suitable for centrals GE50, GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas where a high level of security is required.

DATASHEET

JNT 162

12 345 6 7

Technical Data - Benefits BENEFITS

Technical Faceplate:

2 mm stainless steel

. Excellent speech quality, even from a distance (up to 7m 23 ft).

Measurements: JNT162 faceplate: 180 x 90x2 mm flush mount depth: 25 mm JNTX61U:187 x 92x depth 49/68 mm, 1mm stainless steel. JNTX61UI-1:182 x 109 x depth 35 mm, 1mm stainless steel. JNTX61UI-2:182 x 109 x depth 47 mm, 1mm stainless steel. Microphone:

Omnidirectional electret microphone for max. 7 m (23 ft) speaking distance

Loudspeaker:

Special membrane type for optimal sound quality, sound pressure: 87 dB/1 W/1 m, 50 Ohm

Keyboard:

Possibility of connecting buttons 0, 4, 5, X

Output:

1 relay output 24 V DC/ 1A

Call indication:

. Cabling with 4 wires, star feed, fully analog transmission of speech and data. . DSP-technology, prepared together with ET901AC . Audio-Monitoring, adjustable integration time and noise level. prepared together with ET901AC and with GE300 (G3-GET4B+L3-GET-DSP), GE800 (G8-GET4B+L8-GET-DSP). . Microphone - Loudspeaker Surveilliance prepared together with ET901AC and with GE300 (G3-GET4B+L3-GET-DSP), GE800 (G8-GET4B+L8-GET-DSP).

red operation LED

Call button:

JNT162: flat stainless steel button JNT162M: red mushroom button

Frequency range:

200 — 12,000 Hz

Operating temperature range:

–40˚ C bis +90˚ C (–40˚ F to 194˚ F)

Storage temperature range:

–40˚ C bis +90˚ C (–40˚ F to 194˚ F) up to 95%

Relative humidity: Plug:

pluggable screw terminals

Cabling.

star feed, 4-wire, twisted

Power supply:

from central

Signalling:

Analog system

Mounting:

flush mount box required for flush surface surface mounting (available separately), surface mount boxes JNTX61U, JNTX61UI-1, JNTUI-2.

Weight

JNT162 (363g), JNT162-3 (407g) JNTX61U (296g) JNTX61UI-1 (81g), JNTXUI-2 (216g)

Amplifier: IP Rate

Output power : 0,5W (JNT162 + JNTX61UI-1)IP: 44 (JNT162 + JNTX61UI-2)IP: 44 (JNT162 + JNTX61U)IP: 54

System Requirements GE100, GE200, GE700, GE300, GE800 For flush mounting the flush - mount box JNTX61U out door and JNTX61UI in door (sold separately) is required. For surface mounting, the surface mount box is using se page 2.

. Integrated output for indication led, max 20mA. . Built-in loudspeaker and microphone. . Output contact for direct connection of e.g indication (red lamp). . Stainless steel faceplate. . Operation LED. . Vandal resistant, Weather resistant. . Available with one to three button. . Available with one red mushroom buttons. . Tamper resistant push buttons (function programmable).

Extent of Supply 1 Intercom module including short reference

LINE LENGTH Diameter: [mm]

0.4

0.5

0.6

0.8

1.0

AWG:

26

24

22

20

18

Line length: [m] [ft]

650 2133

1000 3281

1500 4922

2600 8531

4200 13780

All data about line letngths corresponds to a loudspeaker attenuation of approx. 9dB and a microphone attenuation of approx. 3dB.

Extent of supply. Intercom station JNT162 / 162-3 including: 4 screws for mount in box. Surface mount box JNTX61U / including: 1 Cabelgland. Rain shield (covers microphone)

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsvägen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se


Vandal Resistant 4 Wire Terminals. Series JNT162. Analog station : Doors, lifts , help points, prisons suitable for centrals GE50, GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas where a high level of security is required.

JNT162

Connection sample cell (prison) terminals.

12 345 6 7

E5344334

JNT162

1 Connect to subscriber card G7-GET-4B,C,D central GE700 G2-GET-4B,C,D central GE200 G8-GET-4B,C,D central GE800 G3-GET-4B,C,D central GE300

2

1 Volume Loudspeaker

A B C D NO C NC

Volume Microphone

2 pair twisted cable to subscriber port. E5505540

A B C D

Extra call indication.

1

X 4 5

E5344334

Max 20 mA

Indication lamp; follows the function for the light emitting diode in the Cell station. When using the indication lamp E5344334, no extra power supply is necessery.

E5505540 ”0"

2

”X" Reset button.

Call buttons.

Call button. Must be configured in CCT programing tools.

24v DC + 24v DC Power supply

If indication lamp takes more than 20 mA. Use extra power supply. And set switch in position 1.

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsvägen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se


Vandal Resistant 4 wire terminals. Series JNT162. Analog station : Door, lifts , Help points, Prison suitable for centrals GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas in which high requirements of security are needed.

Connection sample door terminals.

JNT162

12 345 6 7

Connect to subscriber card G7-GET-4B,C,D central GE700 G2-GET-4B,C,D central GE200 G8-GET-4B,C,D central GE800 G3-GET-4B,C,D central GE300

1 Volume Loudspeaker

A B C D NO C NC

Volume Microphone

X 4 5

2 pair twisted cable to subscriber port.

A B C D

JNT 162 + JNTX61UI-1

�0"

Call buttons.

Call button. Must be configured in CCT programing tools.

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsvägen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se


Vandal Resistant 4 Wire Terminals. Series JNT162. Analog station : Doors, lifts , help points, prisons suitable for centrals GE50, GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas where a high level of security is required.

Connection sample door, lift terminals.

1 Volume Loudspeaker

12 345 6 7

Connect to subscriber card G7-GET-4B,C,D central GE700 G2-GET-4B,C,D central GE200 G8-GET-4B,C,D central GE800 G3-GET-4B,C,D central GE300 A B C D

A B C D NO C NC

Volume Microphone

JNT162

X 4 5

”5"

”0"

”4"

JNT 162-3 + JNTX61UI-1

Call buttons.

Call button. Must be configured in CCT programing tools.

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsvägen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se


Vandal Resistant 4 Wire Terminals. Series JNT162. Analog station : Doors, lifts , help points, prisons suitable for centrals GE50, GE100. GE200. GE700, GE300, GE800 and IP Box ET901AC Made for areas where a high level of security is required.

JNT162

Measurements

12 345 6 7

JNT 162

MEASUREMENTS INSTRUCTIONS 6 9

16

10

9

DRILL INSTRUCTIONS

90

15 13

25

10

63

31 12,5 5 11

63

31 24 Enables Relay

10

180

Volume Loudspeaker

Volume Microphone

85

3,5

A B C D NO C NC

20

3,5

35

10,2 Mikrophone 10,0

9.8

90 50

10 3,5

148mm

X 4 5

77mm

20 3,5

10,2

3,0 9.8

50

PRECAUTIONS

MOUNTING INSTRUCTIONS

• When opening the stations ESD precautions must be observed.

• Do not expose the station to extreme temperature (under –40˚ C or above +90˚ C / –40˚ F to 1 94˚ F).

• The stations may be opened by authorised service engineers only..

• Please take care that the front panel of the JNT 162 is attached to the mounting plate without margin. Otherwise an “acoustic short circuit“ occurs, which can considerably inuence the sound of the JNT162.

MEASUREMENTS Measuring units: mm , not scale!

Datasheet Version JNT162 2010-12-15 / Errors and omissions excepted / Products may change in the interest of technical improvements without notice.

JNT AB, Solkraftsvägen 35, 13570 Stockholm, SWEDEN, Tel +46(0) 8 993060, Fax +46(0)8 995580, e-mail info@jnt.se

85

Analouge Door station JNT162  