proposed renovation for:
CAPELLA RESIDENCE 4307 39th St. N. Arlington, VA 22207 DESIGN/BUILD BY:
CARNEMARK
7550 Wisconsin Avenue, Suite 120, Bethesda, MD 20814 . tel: 301.657.5000 . fax: 301.657.5070
CAPELLA RESIDENCE 4307 39th St. N. Arlington, VA 22207
PROPOSED RENOVATION FOR:
sheet title:
Cover Sheet
IMAGE
PROJECT INFORMATION
sheet scale:
PROJECT DESCRIPTION NEW DECK AND INTERIOR ALTERATIONS:
ZONING: R-10 SETBACKS: FRONT: WITHIN RANGE OF EXISTING FRONT SETBACKS OF ALL STRUCTURES ON THE SAME SIDE OF THE STREET IN THE BLOCK WHERE THE BUILDING IS SIDES: 10 FT. REAR: 25 FT.
PROPOSED AREA CALCULATIONS:
LOT AREA: 10080 SF
LOT AREA: 10080 SF
MAIN BUILDING FOOTPRINT: 1865 SF
MAIN BUILDING FOOTPRINT: 1865 SF
STOOPS AND LANDINGS: 141 SF
STOOPS AND LANDINGS: 74 SF
DECKS: 0 SF
DECKS: 111 SF
DRIVEWAY: 660 SF
DRIVEWAY: 660 SF
EXISTING MAIN BUILDING FOOTPRINT: 1865 SF EXISTING MAIN BUILDING FOOTPRINT COVERAGE: 18.5%
PROPOSED MAIN BUILDING FOOTPRINT: 1976 SF PROPOSED MAIN BUILDING FOOTPRINT COVERAGE: 19.6%
EXISTING LOT COVERAGE: 2666 SF EXISTING LOT COVERAGE: 26.4 %
PROPOSED LOT COVERAGE: 2710 SF PROPOSED LOT COVERAGE: 26.9 %
sheet date:
08.01.19 drawing revisions:
PROJECT TEAM DESIGNER/BUILDER:
STRUCTURAL ENGINEER:
CARNEMARK DESIGN + BUILD 7550 WISCONSIN AVE SUITE 120 BETHESDA, MD 20814 301-657-5000 CONTACT: MICHAEL GILLEN PROJECT DESIGNER
COLIN MCKENZIE, P.E. MCKENZIE ENGINEERING SERVICES 3408 BROOKWOOD DR SUITE A FAIRFAX, VA 22030 703-359-6868
MAX. BUILDING HT: 35 FT. LOT COVERAGE: 32 % MAX OR 35% MAX WITH (60 SF) PORCH MAIN BUILDING FOOTPRINT COVERAGE: 25% MAX. MAIN BUILDING FOOTPRINT: 3,500 SF. MAX.
LANDSCAPE ARCHITECT:
date: 08.01.19
UTILITIES: WATER CONNECTED GAS CONNECTED
EXISTING AREA CALCULATIONS:
description: CONSTRUCTION
PROPERTY ADDRESS: 4307 39TH ST. N ARLINGTON, VA 22207 LOT: 16 SQUARE: LOT AREA: 10,080 SF HISTORIC DISTRICT: N/A NEIGHBORHOOD: WARD: LEGAL DESCRIPTION: WALTER R. REYNOLDS 1ST ADDITION TO GOLF CLUB MANORS YEAR BUILT: 1957
-NEW POWDER ROOM AND OPENINGS ON FIRST FLOOR. -REMODEL OF KITCHEN AND BATHROOMS. -LIMITED MECHANICAL AND ELECTRICAL WORK
CODES & STANDARDS - ARLINGTON COUNTY, VA APPLICABLE CODES: ZONING: 2018 ARLINGTON COUNTY ZONING ORDINANCE (ACZO) BUILDING: 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) 2012 VIRGINIA RESIDENTIAL CODE (VRC) 2012 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) ENERGY:
2012 VIRGINIA ENERGY CONSERVATION CODE
DRAWING INDEX 001 002
Cover Sheet Legend and Notes
MEP0
C001
Existing and Proposed Site Plans
MEP1
A010
Existing Basement and Lower Split Level Plan Existing First Floor and Upper Split Level Plan Existing Roof Plan Existing Exterior Elevations Existing Exterior Elevations
A011 A012 A020 A021
7/16/2019 12:42:54 PM C:\Users\jnguyen\Documents\1813‐Capella‐Interior and Deck_jnguyen.rvt
D001 D002
A100
Basement and Lower Split Level Demolition Plans First Floor and Upper Split Level Demolition Plans
A102 A200 A201
Proposed Basement and Lower Split Level Plan Proposed First Floor and Upper Split Level Plan Proposed Roof Plan Proposed Exterior Elevations Proposed Exterior Elevations
A300 A301 A302
Proposed Interior Elevations Proposed Interior Elevations Proposed Interior Elevations
A400 A500 A600
Proposed Building Section Details Schedules & Notes
A101
S001 S100 S101 S102
Proposed Basemnet and Lower Split Level MEP Plan Proposed First Floor and Upper Split Level MEP Plan Structural Notes Proposed Foundation Plan Proposed First Floor Framing Plan Proposed First Floor Ceiling Framing Plan
THE ABOVE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF CARNEMARK SYSTEMS AND DESIGN INC. AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONJUNCTION WITH ANY WORK OR PROJECT OR BY ANY OTHER PERSON FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF CARNEMARK SYSTEMS AND DESIGN INC. VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSION.
BUILDING CODES & STANDARDS
CARNEMARK ©
VICINITY MAP
7550 Wisconsin Avenue, Suite 120, Bethesda, MD 20814. tel: 301.657.5000
rev.#
[NAME] [ADDRESS 1] [ADDRESS 2] [CITY, STATE, ZIP CODE] [PHONE NUMBER] [CONTACT]
001