Issuu on Google+

Versatile Implants Internal Hex & One Piece


Dentalis Bio Solution complies with ISO 13485, ISO 14001 and Council Directive 93/42/EEC Canadian Medical Devices Regulation.

Dentalis Bio Solutions USA 9650 E 148th St Noblesville, 46060 Indiana, USA Phone: 317-214-7076 For more info please refer to WWW.dentalis.us or to your local distributor For USA Only: Federal Law restricts this device to sale by or the order of licensed dentist or physician


The Perfect Match ™

Who we are Dentalis BioSolutions R&D is focused on becoming a leader in the application of nanotechnology, bioinorganic materials with wider functionalities “intelligent” bone substitutes life sciences. We strive to become the new industry standard for detection of molecular protein-Hormone-growth factor interactions. Dentalis R&D department is a unique combination of individual parts. We have assembled multi-disciplinary teams of scientists with diverse research and technical knowledge and life experiences. Our project teams are made of organic chemists, biologists, physicists, biochemists, and materials science engineers working side by side toward common goals. Our product development specialize in a wide range of fields, focusing on orthopedic and dental implant, research of Surface Science and Technology encompasses both analysis and modification of surfaces.

Our offer

Dentalis offers an extensive variety of bone and tissue level implants for all indication and bone types, which satisfies every clinician and selected treatment concept, such as one and two stage surgical, immediately or delayed loading protocol, solutions for a wide clinical situations from the basic to the most complex with wide range of length implants from 20 mm to 6.5 mm, wide & short implant, Narrow implant Ø 3 mm diameter designed specifically for limited spaces in the esthetic zone and limited ridge. All Dentalis implant are made from Titanium Alloy [Ti-6Al-4V] which is biocompatible medical grade. The surface of All Dentalis implant is roughened by biocompatible material (HA) and is free from any contamination (Aluminum oxide and acid traces).

Our belief

We believe that creativity and innovation in orthopedics implant and dentistry requires vision and commitment to patient quality of life. We are convinced that this focus must permeate and inspire everything we do, every day.

Our commitment

We are devoted to continue on providing high quality, groundbreaking oral healthcare solutions that create value for dental professionals and enhance their patients’ quality of life

Dentalis follows the most strict international quality standards, complying with ISO 13485:2003 quality management system for : Design, development & manufacture of Orthopedics, Bone Screw, Dental implant, Plates and other medical instrument.

All rights reserved. No Part of this publication may be reproduced, transcribed, stored in an electric retrieval system and translated into any language or computer language without the prior written consent of the Dentalis Bio Solution R&D.


Disclaimer of Liability

Dentalis implants is a part of an overall concept and may only be used in conjunction with the associated original components and instruments according to Dentalis instructions and recommendations. Use of any non- Dentalis products in conjunction with Dentalis implants will avoid any warranty Or any other obligation, expressed or implied, of Dentalis. Instructions as to application of our products take place verbally, in writing, by electronic media or in handson training corresponding to state of the art at the time of introduction of the product. The user of Dentalis product has the duty to determine whether or not any product is suitable for the particular patient and circumstances. Dentalis disclaims any liability, express or implied, and shall have no responsibility for any direct, indirect, punitive or other damage, arising out of or in connection with any errors in professional judgment or practice in the use or installation of Dentalis products.

Please note

The descriptions given are insufficient to allow immediate use of the Dentalis dental Implant Systems. Guidance in the handling of this instrument by a doctor experience in their use is strongly recommended.

Unit per package

Unless stated otherwise, there is one unit in each package.

Availability

Not all product listed in this brochure are available in all countries.

Validity Upon publication of this brochure, all previous versions are superseded.

Caution

As a general rule, our product must be secured against aspiration when used intra-orally.

Copyright and trademarks

All rights reserved. Dentalis documents may not be reprinted No Part of this publication may be reproduced, transcribed, stored in an electric retrieval system and translated into any language or computer language without the prior written consent of the Dentalis Bio Solution R&D, Dentalis- Dental implants system, Versatile implant, T1, S2, D2, Micro Cortical thread, BAS surface are registered trademarks . Some products may not be regulatory cleared/released for sale in all markets and not all may have been licensed in accordance with Canadian law. Please contact the local Dentalis sales office for current product range and availability.

Valid from 1 January 2013 until publication of new catalog. Note: In order to improve readability, Dentalis Bio Solutions does not use ™ or ® in the running text. By doing so, however, Dentalis does not waive any right to the trademark or registered mark and nothing here in shall be construed to the contrary.

The following third-party trademarks apply:

Ankylos® is a trademark of Dentsply Friadent Group, Astra Tech® of Astra Tech Group, Bredent™ of Bredent GmbH & Co. KG, Camlog® of Camlog Biotechnologies Group, Dolder® and Dalbo® of Cendres+Metaux SA, Lifecore® Biomedical Restore of Lifecore Biomedical Group, Locator® of Zest Anchors Inc, Sterngold® Implamed of Sterngold Group, Straumann® of Institut Straumann AG, Telio® CAD and IPS e.max® CAD of Ivoclar Vivadent AG, 3i® of Biomet Group, Thommen® of Thommen Medical AG, and Zimmer® Dental of Zimmer Group.

Dentalis Bio Solution complies with ISO 13485, ISO 14001 and Council Directive 93/42/EEC Canadian Medical Devices Regulation.


contents Explanation of the symbol

1

BAS Surface

2 -3

Vi -Versatile Implant Narroe platform Standart Platform VOne piece Anatomic VOne piece implant

4 - 26 6 - 8 9 - 15 16 - 20 22 - 26

Healing Abutment

28 - 29

Screw Type & Cemented Rehabilitation

30 - 37

30 31 32 32- 33 34 35 36 37

Temporary Abutment Plastic structure for casting Non Hex Abutment Straight Abutment Zirconium Abutment Angled Abutment Anti-Rotation Aestheic Abutmen Straight adaptor

Overdenture 38- 40 Ball Attachment Abutment 38- 39 Angular Ball Attachment Abutment Locator Abutment 40 Implant impression Transfer

Analog & Transfer

41- 42

Surgical Kits, Tools, Surgial Drllis

44- 51

45 46- 47 48 48 49 49 50 50 50 51

Drivers & Tools Drills -External Irrigation Drills- Conical Ceramic Drill Counter Sink Trephine Burs Sinus Kit Paralel Pin Osteotomes Kit Professional Implantology Tools


Explanation of the symbols on labels and instructions for use Single Use

Do not re-sterilize.

Manufaturer

Date of manufactre

Use Before expiry date

Temperature limitation

Catalogue number

Lot / batch number/code

non-sterile

Sterlilzed using gamma irradiation

Keep away from sunlight

Protect from exaposre to light or heat

Attention,refer to instructions for use Caution:Federal (USA)law restricts this product to sale directly to, or on the order of a licened dentist Dentalis products carry the CE mark and fulfill the requirment of the medical Decices Directive 93/42 EEC

Do not use if package is damaged

GOST is the valid quality certification system in Russian Federation. xxxx identify the notified body of manufacturer

Extra Important when using Dentalis Implants

We strongly recommend that practitioners, new as well as experience implant user, always go through special training before undertaking a new treatment method. A training model and two dummy implants are also delivered with the surgical kit. Dentalis Bio Solution provides wide range of courses for various levels of knowledge. All products are subject to change without notice. Some products may not be available in all markets Please contact your local Dentalis Office for current product assortment and availabilty

Dentalis Bio Solutions USA, 9650 E 148th St, Noblesville, 46060, Indiana, USA

1


The Perfect Match ™

BAS™ Surface Introduction:

Bio Active Surface

Implant success is dependent on the osseointegration process. Successful osseointegration of bone growth around an implant is dependent on substrate properties, including surface morphology, chemical composition and surface energy. Dentalis’s dental implant innovation was developed and tested in three essential research levels and has the advantages to enhance immediate and successful osseointegration. _ entalis’s new implants encompass unique and advanced implant D macrotopography. Dentalis’s implant’s chemical composition is well characterized. Dentalis’s implant surface was produced with specific micron scale surface structures. Dentalis’s implants were examined and established under in vitro cell culture studies and in vivo conditions. In vitro findings have established that these specific surface structures enhanced osteoblast attachment, proliferation, differentiation, and mineralization. In vivo studies have confirmed the osteogenic effect of microstructures on Ti substrates. These surfaces improved bone to implant contact (BIC) in comparison with smooth surfaced implants, and this was correlated with greater removal torque strength. These observations suggest that Dentalis implants, inspired by bone biology, will improve your clinical performance and outcome. For more info about BAS ™ Surface and the Scientific Research Documentation In vitro & In vivo experiments please contact your local distributor.

2


Roughness analysis

Dentalis Surface roughness is achieved from grit-blasting using a unique combination of the HA particles (soluble) with different size of grains. This process provide the surface its optimal structural roughness and enables the incorporation of biocompatible particles such as HA and TCP.

BAS ™ surface Scanning Electronic Microscopy (SEM) of implant surface Dentalis surface, the roughening process produces a larger and cleaner surface.

Implants

Determination of Ra values

Roughness was measured with an average roughness (Ra), the most commonly used parameter for describing roughness, was calculated in microns. The rough surfaces produced by grit-blasting had irregular geometries with Ra value of 3.0 μm, which is considered optimal for the osseointegration process.

Biological Response - In Vitro Study

In vivo :

studies have confirmed the osteogenic effect of microstructures on Ti substrates. These surfaces improved bone to implant contact (BIC) in comparison with smooth surfaced implants, and this was correlated with greater removal torque strength. These observations suggest that Dentalis implants, inspired by bone biology, will improve your clinical performance and outcome. For more info about BAS ™ Surface and the Scientific Research Documentation In vitro & In vivo experiments please contact your local distributor.

3

The Drilling sequrnce is demontrated by a 13 mm implant

Dentalis’s implant surface is the result of comprehensive scientific research. The surface characteristics of dental implants to optimize the biological response. Research on Dentalis surface examine the next properties: Alkaline phosphatase as an early marker of differentiation and reaches its highest levels as mineralization is initiated. Osteocalcin is a late marker of differentiation and increases as mineral is deposited. Prostaglandin E2 is required for osteoblast activity and prostaglandins mediate cell response to surface structure. Most of the transforming growth factor beta-1 secreted by MG63 cells on microstructured Ti surfaces is stored in latent form, and the amount is sensitive to surface structure. These growth factors stimulate matrix synthesis and differentiation of osteoblasts and also inhibit osteoclasts.


Versatile Implant VI is a short name for Versatile because of the wide clinical range suitability of bone types, places and bone augmentation. The Vi Implant body designed with narrows conically core, while outer thread diameter of the cylinder remains almost the same, This design gives to VI the facilitating of the self-tapping property and enhance immediate stability. while the core is more tapered is condensing the bone, vertical and horizondual threads, with Dual spiral channels, MicroThreads, Platform switching and domed Apex. The new Vi offer also Horizontal grooves and, Unique grooved threads. Platform switching enables good adaptation of the gingival tissues to the abutment and prevents cervical bone resorption. Horizontal grooves produced by micro-machining impedes epithelial down growth on titanium implants. Micro threads provide enhanced initial stability and increases contact area to crestal bone, which will enhance osseointegration at the crestal bone level.

Implants

Smart Design Simple Use

superior advantages:

Unique grooved threads enhance bone stabilization during primary stabilization and increase the amount of bone to implant contact, which enhances osseointegration. Self-tapping cutting threads facilitate implant placementand enhance primary stability. Rough surface BAS™ which uses combination of resorbable blast material and mimics the surface produced by osteoclasts.Proven to induce bone in vitro and enhance osseointegration in vivo. Sharp threads and spiral deepening from cervical to apical region improve cutting ability with better bone to implant contact for better primary stability. For more info about BAS ™ Surface and the Scientific Research Documentation In vitro & In vivo experiments please contact your local distributor.

4


Implants

Caution :Placement in the molar region is not recommended

5


Vi -Narrow Platform-Implant range

Narrow Vi Was designed especially for narrow spaces in the anterior region. it is a two-pieces implants, with body narrows conically, while outer thread diameter of the cylinder remains almost the same, facilitating the self-tapping property and enhancing immediate stability. With his design it is recommended for all bone types and can achive high primary stability in soft bone.

Caution :Placement in the molar region is not recommended

Implants

Narrow Vi™ has Dual thread and Dual spiral channels With his design he can provide shorten drilling protocols, it is self driling, self tapping and self condensing bone and the advantage to preserving the marginal bone with Micro threads provide enhanced initial stability and increases contact area to crestal bone, which will enhance osseointegration at the crestal bone level. Sharp threads and spiral deepening from cervical to apical region improve cutting ability with better bone to implant contact for better primary stability Maximum bone preservation -Active Apex Apex with drilling blades enables smaller ostotomy. with variety of length from 10 mm to 16 mm and Diamter range of from 3 mm to 3.3 mm.

6


VI – Versatile Implant Body Diameter Ø 3mm Apical Diameter 3.2 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

No Machined Collar Height Length mm

10

Cat. No.

11.5

153010

153011

13 153013

16 153016

Cover Screw

Implants

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

9001200

8001000

500700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 2.8

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 2.8Ø in soft bone (D4) use the 2.5 Ø drill as a final drill just for the cortex.

Vi Ø 3.0

7

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.


VI – Versatile Implant Body Diameter Ø 3.3mm Apical Diameter 2.9 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

No Machined Collar Height Length mm

10

Cat. No.

11.5

153310

13

153311

16

153313

153316

Cover Screw

Implants

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

8001000

500700

400700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 3.2

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.3Ø in soft bone (D4) use the 2.5 Ø drill as a final drill just for the cortex.

Vi Ø 3.3

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

8


Vi-Implant Range-Standart Platform VI – Versatile Implant Body Diameter Ø 3.25mm Apical Diameter 3.2 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

No Machined Collar Height Length mm Cat. No.

6.5

08

-

10

153208

153210

11.5 153211

13 153213

16 153216

Cover Screw

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

Implants

500700

400700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 2.8

8001000

Ø 2.5

9001200

Ø2

9001200

Vi Ø 3.25

9

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Dentalis Bio Solution complies with ISO 13485 and Council Directive 93/42/EEC

Drill Speed (RPM)

Ø 3.2

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.25Ø in soft bone (D4) use the 2.5 Ø drill as a final drill just for the cortex.


VI – Versatile Implant Body Diameter Ø 3.75mm Apical Diameter 3.2 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

No Machined Collar Height

|

Platform Switching

Length mm

08

6.5

Cat. No.

-

10

153708

153710

11.5

13

153711

153713

16 153716

Cover Screw

500700

400700

400600

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Implants Ø 3.6

8001000

Ø 3.2

9001200

Ø 2.8

9001200

Ø 2.5

Drill Speed (RPM)

Ø 3.6 / 4.1

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.75Ø in soft bone (D4) use the 3.2 Ø drill as a final drill just for the cortex.

Ø2

For USA Only: Federal Law restricts this device to sale by or the order of licensed dentist or physician

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

Vi Ø 3.75

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

10


VI – Versatile Implant Body Diameter Ø 4.2mm Apical Diameter 3.7 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

No Machined Collar Height

|

Platform Switching

Length mm

08

10

Cat. No.

6.5 154206

154208

154210

11.5 154211

13 154213

16 154216

Cover Screw

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

Implants

400600

400600

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 4.1

400700

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 3.6 / 4.1

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 4.2Ø in soft bone (D4) use the 3.6 Ø drill as a final drill just for the cortex.

Vi

Ø 4.2

11

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.


VI – Versatile Implant Body Diameter Ø 4.7mm Apical Diameter 3.7 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

No Machined Collar Height

|

Platform Switching

Length mm

08

6.5

Cat. No.

154706

10

154708

11.5

154710

13

154711

154713

16 154716

Cover Screw

Implants

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 4.7Ø in soft bone (D4) use the 4.1 Ø drill as a final drill just for the cortex. 400600

300500

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 4.6

Ø 4.6

400600

Ø 4.1

400700

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Vi Ø 4.7

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

12


VI – Versatile Implant Body Diameter Ø 5mm Apical Diameter 3.7 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm Machined Collar Height : 0.5 mm Length mm

6.5

Cat. No.

15506

|

SP-Standard Platform

|

Platform Switching

08 155008

10

11.5

155010

155011

13 155013

16 155016

Cover Screw

Implants

Dentalis Bio Solution complies with ISO 13485 and Council Directive 93/42/EEC

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

400600

300500

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 4.6

Ø 4.6

400600

Ø 4.1

400700

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 4.8/ 5.8

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 5.0 Ø in soft bone (D4) use the 4.6 Ø drill as a final drill just for the cortex.

Vi Ø5

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

13


VI – Versatile Implant Body Diameter Ø 5.5mm Apical Diameter 3.7 mm Minimum Ridge Width 5.25 mm Minimum Mesial / Distal Space 6.25 mm Micro & Mini Ring 3 mm

|

SP-Standard Platform

|

Platform Switching

Machined Collar Height : 0.5 mm Length mm

6.5

Cat. No.

08

15506

155008

10

11.5

155010

155011

13 155013

16 155016

Cover Screw

Implants

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 5.5Ø in soft bone (D4) use the 4.6 Ø drill as a final drill just for the cortex. 300500

300500

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 4.6

Ø 5.2

The Drilling sequrnce is demontrated by a 13 mm implant

Ø 5.2

400600

Ø 4.6

400600

Ø 4.1

400700

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Vi Ø 5.5

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

14


VI – Versatile Implant Body Diameter Ø 6mm Apical Diameter 5.5 mm Minimum Ridge Width 8 mm Minimum Mesial / Distal Space 9 mm Micro & Mini Ring 3 mm Machined Collar Height 0.5mm Length mm

6.5

Cat. No.

|

SP-Standard Platform

|

Platform Switching

08

156006

156008

10

11.5

156010

156011

13

16

156013

156016

Cover Screw

Include with all implants.Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.

Implants

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 6.0 Ø in soft bone (D4) use the 5.2 Ø drill as a final drill just for the cortex. 300500

300500

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 4.6

Ø 5.2

Ø 5.8

Ø 5.8

300500

Ø 5.2

400600

Ø 4.6

400600

Ø 4.1

400700

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Vi Ø6

15

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.


Versatile One Piece Anatomic Introduction Dentalis One-Piece implants feature benefit The VOne Piece Anatomic implant encompasses the osseous component and restorative component in one piece. It Bring greater simplicity and convenience to the restoration process, One Piece, Titanium construction eliminates micro movement and saves time required to connect the abutment. This design is based on the one-stage placement concept and offers a number of possible advantages: V1 is especially design to restore with an excellent esthetic result in the mandibular central and lateral incisors or maxillary lateral, narrow implant diameters and tapered body design allow for various placement options in the esthetic zone. With 2.9 mm implant diameter allows placement in the limited tooth spacing of themaxillary laterals and mandibular laterals / incisors.

Implants

3.7mm and 4.7 implant diameters provide additional options in all tooth locations. VOne Piece Anatomic is Multi lead threads enable faster insertion while maintain implant stability with an integrated abutment designed for one stage surgical procedures and cemented restorations. Tissue friendliness: The surgery is performed only once, allowing the soft tissue to adapt to the implant / abutment interface without further manipulation. The Minute-Threads system enhances the contact area between implant and bone Horizontal Micro-Groove grooves produced by micro-machining will impede epithelial down growth on titanium implants. Micro and Mini Cortical Thread™ maintains the marginal bone and offers for this reason a good foundation for a long-term esthetic result. The BAS™ surface on V1 enables more rapid formation and greater amount of bone to implant contact during healing, Dentalis Bio Solution surfaced implant result in faster and stronger osseointegration and better maintenance of the initial implant stability . For more info about BAS ™ Surface and the Scientific Research Documentation In vitro & In vivo experiments please contact your local distributor.

16


VA– Versatile One Piece Anatomic Body Diameter Ø 2.9mm Apical Diameter 2.5 mm Minimum Ridge Width 6.2 mm Minimum Mesial / Distal Space 7.2 mm Micro & Mini Ring 3 mm Length mm Cat. No.

10

11.5

152910

152911

13

16

152913

152916

Implants

9001200

8001000

500700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 2.8

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 2.9Ø in soft bone (D4) use the 2.5 Ø drill as a final drill just for the cortex.

VA Ø 2.9

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

17


VA– Versatile One Piece Anatomic Body Diameter Ø 3.3mm Apical Diameter 2.8 mm Minimum Ridge Width 6.2 mm Minimum Mesial / Distal Space 7.2 mm Micro & Mini Ring 3 mm 10

Cat. No.

11.5

153210

13

153211

16

153213

153216

Implants

Length mm

8001000

500700

400700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 3.2

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.3Ø in soft bone (D4) use the 2.8 Ø drill as a final drill just for the cortex.

VA Ø 3.3

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

18


VA– Versatile One Piece Anatomic Body Diameter Ø 3.75mm Apical Diameter 3.2 mm Minimum Ridge Width 6.2 mm Minimum Mesial / Distal Space 7.2 mm Micro & Mini Ring 3 mm Length mm

10

Cat. No.

11.5

153710

153711

13

16

153713

153716

Implants

400700

400600

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 3.2

500700

Ø 2.8

8001000

Ø 2.5

9001200

Ø2

9001200

VA Ø 3.75

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

19

Dentalis Bio Solution complies with ISO 13485 and Council Directive 93/42/EEC

Drill Speed (RPM)

Ø 3.6

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.75Ø in soft bone (D4) use the 3.2 Ø drill as a final drill just for the cortex.


VA– Versatile One Piece Anatomic Body Diameter Ø 4.2mm Apical Diameter 3.7 mm Minimum Ridge Width 6.2 mm

Cat

Minimum Mesial / Distal Space 7.2 mm

Ver Pie

Micro & Mini Ring 3 mm Length mm

10

Cat. No.

11.5

154210

154211

13

An

16

154213

Ø4

154216

400700

400600

400600

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 4.1

Implants

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 4.2Ø in soft bone (D4) use the 3.6 Ø drill as a final drill just for the cortex.

VA Ø 4.2

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

20


Implants

21


VO – Versatile One Piece Implant Introduction Dentalis One-Piece implants feature benefit The V1 implant encompasses the osseous component and restorative component in one piece. It Bring greater simplicity and convenience to the restoration process,One Piece, Titanium construction eliminates micro-movement and saves time required to connect the abutment. This design is based on the one-stage placement concept and offers a number of possible advantages: V1 is especially design to restore with an excellent esthetic result in the mandibular central and lateral incisors or maxillary lateral, narrow implant diameters and tapered body design allow for various placement options in the esthetic zone. With 2.9 mm implant diameter allows placement in the limited tooth spacing of themaxillary laterals and mandibular laterals / incisors.

Implants

3.7mm and 4.7 implant diameters provide additional options in all tooth locations. The V1 is Multi- lead threads enable faster insertion while maintain implant stability with an integrated abutment designed for one stage surgical procedures and cemented restorations. Tissue friendliness: The surgery is performed only once, allowing the soft tissue to adapt to the implant / abutment interface without further manipulation. The Minute-Threads system enhances the contact area between implant and bone Horizontal Micro-Groove grooves produced by micro machining will impede epithelial down growth on titanium implants. Micro and Mini Cortical Thread™ maintains the marginal bone and offers for this reason a good foundation for a long-term esthetic result. The BAS™ surface on V1 enables more rapid formation and greater amount of bone to implant contact during healing, Dentalis Bio Solution surfaced implant result in faster and stronger osseointegration and better maintenance of the initial implant stability. For more info about BAS ™ Surface and the Scientific Research Documentation In vitro & In vivo experiments please contact your local distributor.

22


V1 – Versatile One Piece Implant Body Diameter Ø 2.9mm Apical Diameter 2.5 mm Minimum Ridge Width 4.9 mm Minimum Mesial / Distal Space 5.9 mm Micro & Mini Ring 3 mm Length mm Cat. No.

10

11.5

152910

152911

13 152913

16 152916

Implants

9001200

8001000

500700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 2.8

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 2.9Ø in soft bone (D4) use the 2.5 Ø drill as a final drill just for the cortex.

VO Ø 2.9

23

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.


V1 – Versatile One Piece Implant Body Diameter Ø 3.3mm Apical Diameter 2.5 mm Minimum Ridge Width 5.3 mm Minimum Mesial / Distal Space 6.3 mm Micro & Mini Ring 3 mm 10

Cat. No.

11.5

153310

13

153311

16

153313

153316

Implants

Length mm

8001000

500700

400700

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 3.2

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.3Ø in soft bone (D4) use the 2.8 Ø drill as a final drill just for the cortex.

VO Ø 3.3

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

24


V1 – Versatile One Piece Implant Body Diameter Ø 3.75mm Apical Diameter 3.2 mm Minimum Ridge Width 5.75 mm Minimum Mesial / Distal Space 6.75 mm Micro & Mini Ring 3 mm Length mm Cat. No.

10

11.5

153710

13

153711

16

153713

153716

Implants

400700

400600

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 3.6/4.1

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.75Ø in soft bone (D4) use the 3.2 Ø drill as a final drill just for the cortex.

VO Ø 3.75

25

Dentalis Bio Solution complies with ISO 13485 and Council Directive 93/42/EEC


V1 – Versatile One Piece Implant Body Diameter Ø 4.2mm Apical Diameter 3.7 mm Minimum Ridge Width 6.2 mm Minimum Mesial / Distal Space 7.2 mm Micro & Mini Ring 3 mm 10

Cat. No.

11.5

154210

154211

13

16

154213

154216

Implants

Length mm

400700

400600

400600

Drill Diameter (mm)

Ø 1.8

Ø2

Ø 2.5

Ø 2.8

Ø 3.2

Ø 3.6

Ø 4.1

Ø 3.6

500700

Ø 3.2

8001000

Ø 2.8

9001200

Ø 2.5

9001200

Ø2

Drill Speed (RPM)

Ø 4.1

Recommendation : to reduce the pressure in the bone around the implant neck: Bone Type D1 use the last drill up to 1/3 depth. Bone Type D2-3 use the last drill to the depth of the cortex. Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 4.2Ø in soft bone (D4) use the 3.6 Ø drill as a final drill just for the cortex.

VO Ø 4.2

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

26


27


Healing Protocols Cover Screw Caps for two-stage protocol Purpose: Protects prosthetic-platform in two-stage (submerged) surgical protocols.Irrigate implants to remove blood and other debris, Remove Cover Cap from implant vial with 0.50”(1.25mm)Hex Driver, Hand- tighten(10-15 Ncm) utilizing 0.50”(1.25mm) Hex Driver An Antibacterial paste may be places on the end of the Cover Screw Cap to help decrease the risk of bacterial growth within the implant body during the healing phase. Following placement of the Cover Screw Cap, the surgical site should be irrigated and soft tissue adapted in a normal surgical fashion.Take precautions to prevent the Cover Screw Cap from being aspirated by the patient. Material Titanium

Indication of use Healing Abutment The Healing Abutment is specially designed to avoid bone grow on platform and to developing soft tissue emergence with Narrow, Regular, Wide Emergence or simple solutions internal system prosthetic components, by that to prepare for the specially designed bridge impression coping and remains in the jaw until soft tissue (the gums) heal. To be used as a transmucosal extraction extension secures to the implant during healing of intra-oral soft tissue following insertion of the implant to the bone or after second stage surgery. For esthetic result use appropriate Healing caps type, selected height a function of the thickness of the gums. Select the emergence profile that best suits the site being restored. The profile should match the transfer and abutment to be used Select the cuff height so that the top of the component protrudes slightly above the surrounding thickness tissue gums. The options are from 2mm to 7mm.

Placement of the Healing abutment After radiographic verification, a healing abutment screw is then placed, after uncovery two stage surgical protocol. Or in lieu of a Cover screw in a single-stage (non submerged) protocol. Prior to seating the Healing Abutment, thoroughly irrigate the inside of the implant to remove blood and other debris. An antibacterial paste may be placed on the screw portion to decrease the risk of bacterial growth within the implant body during the healing phase. Following seating, irrigate the surgical site and adapt the soft tissue in normal surgical fashion. A gingivectomy or apically positioned flap technique may be used to reduce the soft tissue thickness and to decrease sulcular depth around the implant. All Dentalis® keys are design that the tip is con to grab the healing cap for easy carry the Cover Screw onto the implant and thread it into place. Use the Hand Driver-tighten (10-15 Ncm ) with the 1.25mm- 050” Hex Driver. Dentalis implant is offering special tool for measuring the high level of the tissue for better esthetic result and wide range type of Healing abutment. Take precautions to prevent the Healing Abutment from being aspirated by the patient. Do not re-use Healing abutment. Material Titanium

28


Healing Abutment For D2 - One Piece Implant

Healing Abutments For Narrow Platform Implant H

Cat. NO.

H:2mm 300102

H:3mm 300103

H:4mm 300104

H

H:2mm 300202

H:5mm 300105

H:3mm 300203

H:4mm 300204

H:5mm 300205

Healing abutment Regular Ø 4.7

Narrow Healing Abutment Standaed Platform

H

Cat. NO.

H:2mm 300302

H:3mm 300303

H:5mm 300305

H:2mm 300402

H:7mm 300307

Healing Abutment Esthetic

Cat. NO.

H:3mm 300603

H:4mm 300604

H:5mm 300605

Cat. NO.

H:3mm 300403

H:5mm 300405

H:7mm 300407

Wide Healing Abutment

Narrow Temporary Abutment

Ø 4.5 300500

Ø 3.5 300800

Hand-tighten (10-15Ncm)utilizing. 0.50” (1.25mm) Hex Driver Hand Driver K2S K2L

Tissue Measuring Post

L : 09 800912

29

L : 16 801612

300202


Temporary Abutment A temporary non-hex abutment for immediate loading, made of Titanium

H

Cat. NO.

LS:1mm 300801

LS:2mm 300802

LS:3mm 300803

LS:4mm 300804

LS:5mm 300805

The Plastic sleeve set available in 3 hardness levels, is connected by a “click” to the abutment

Hard 315001

Standard 315002

Soft 315003

Peek Temporary Abutment For fabrication of cement-or screw-retained provisional retorations ( up to 30days). made from Polymer with high performance, biocompatible thermoplastic designd for medical device application. The peek is an ideal substance for medical use in genral and dental use in particular packaged with Abutment Screw. Final Torqe:30Ncm Peek Temporary Straight Abutment packaged with Abutment Screw.

Cat. NO.

H:1mm 310701

H:2mm 310702

H:3mm 310703

Peek Temporary Angular Abutment 15°

Cat. NO.

PTA 15°-H:1 314151

PTA 15°-H:2 314152

PTA 15°-H:3 314153

Peek Temporary Angular Abutment 25°

PTA 25°-H:1 314251

PTA 25°-H:2 314252

PTA 25°-H:3 314253

30


Plastic structure for casting Available with two options: with or without a external hex that need to go in the internal Hex of the implant. They are without internal threading. The sleeve without the hexagon can be use for multi-implant tasks. The sleeve with the External hex is planned to manufacture a structure on set a crown or bridge that fits onto the abutment or just single implant. Plastic Sleeve

H:15

Restorative Products

Cat. NO.

H

With Hex 310215

No Hex 310115

H:9mm 310509

Straight Antomic Plastic Sleeve

H

Cat. NO.

H:1mm 310701

H:2mm 310702

H:3mm 310703

Angular Antomic Plastic Sleeve 15°

H: Height bucc mm 1, 2, 3

Cat. 15° - H:1mm 314151 NO.

15° - H:2mm 314152

15° - H:3mm 314153

Angular Antomic Plastic Sleeve 25°

Packaged with Abutment Screw

Cat. 25° - H:1mm NO. 314251

31

25° - H:2mm 314252

25° - H:3mm 314253 To close the Plastic Sleeve use Final Torqe :15Ncm


Non-Hex Abutment The use of non hex Abutment is for connecting two implants or more by using a permanent rod. The threaded type abutment has neither screw nor hex Can be use in permanent and final restoration. Use the Hand Driver-tighten with the 1.25mm- 050� Hex Driver. Made of Titanium Grade 5 Non-Hex Abutment

Non-Hex Abutment With Upper Hex

L:Vertical height

L:9mm 400309

L:13mm 400313

L:9mm 401309

L:13mm 401313

Restorative Products

Cat. NO.

Straight Abutment Straight Abutment for Narrow Platform

H: Height bucc mm 1, 2, 3

Cat. NO.

H:1mm 400101

H:2mm 400102

H:3mm 400103

Straight Abutment For Dual Implant

Cat. NO.

L:9mm 400201 To close the Abutment use Final Torqe :30Ncm

32


Straight Abutment Straight Abutment Narrow Ø 3.5 mm

L

Cat. NO.

L:5mm 400405

L:7mm 400407

L:9mm 400409

Straight Abutment Regular Ø 4.5 mm

Restorative Products

L H

Cat. NO.

H:1.5-L:9mm 400509

H:1.5-L:12mm H:1.5-L:15mm 400512 400515

Straight Abutment Wide

Straight Abutment for Emerged Profile

H:9mm

Cat. NO.

400610

400609

Straight Abutment With Shoulder TiN Coated [Ti-6Al-4V]

Esthetic Straight Abutment

L:9mm H

Cat. NO.

33

H:1mm 400701

H:2mm 400702

H:3mm 400703

To close the Abutment use Final Torqe :30Ncm

400801 For more info please refer to WWW.dentalis.us


Zirconium Anatomic Abutment Design for Ideal aesthetic solutions with Strong mechanical force. The shape of the anatomic abutment is planned also to reduce the technician’s working time. Made of Composed of 99.8% Zirconium that assists in achieving a strong and stable product.

Zirconuim Anatomic Abutment

L

Restorative Products

H

Cat. H: 1mm L:9mm H: 2mm,L:9mm H: 3mm,L:9mm 400901 400902 400903 NO.

Zirconuim Anatomic Angular Abutment 15°

H:Height bucc mm 1, 2, 3 Cat. NO.

15° - H :1 415151

15° - H :2 415152

15° - H :3 415153

To close the Abutment use Final Torqe :30Ncm

Zirconuim Anatomic Angular Abutment 25°

packaged with Abutment Screw. Cat. NO.

25°- H :1 415251

25°- H :2 415252

Hand Driver K2L

K2S

25°- H :3 415253

Some products may not be available in all markets Please contact your local Dentalis Office for current product assortment and availabilty

34


Angled Abutment Angled Abutment 15° with Shoulder for Narrow Platform

L:9 H

Cat. NO.

H:1mm 411151

H:2mm 411152

H:3mm 411153

M 1.4 700023

Angled Abutment 15° for D2 Implant

Restorative Products

Cat. NO.

412150

1-72 UNF 700027

Angled Abutment Standard platform

Cat. NO.

10° 413101

15° 413150

15° 413151

25° 413259

Anatomic Angular Abutment 15°

Cat. No.

35

15° - H:1mm 414151

15° - H:2mm 414152

15° - H:3mm 414153

30° 413309

35° 413359

Anatomic Angular Abutment 25°

25°- H:1mm 414251

To close the Abutment use Final Torqe :30Ncm

25°- H:2mm 414252

25°- H:3mm 414253


Anti rotation Aesthetic Abutment AAA is short name, This abutment is design with two hex in the upper and bottom, A Plastic casting sleeve can be attached to the upper hex. The plastic sleeve are available with or without an internal hex that fit to the upper External hex of the abutment. This abutment can be suitable for single implant restoration, a screw retained bridge, and raising the height for performing various procedures, e.g., overdentures, bridges, bars and removable dentures.

Restorative Products

Available in four heights: 1, 2, 3 and 4 mm. Made of Titanium Grade 5.

H

Cat. No.

H:1mm 501101

H:2mm 501102

H:3mm 501103

H:4mm 501104

Cat. No.

300201

300202

300203

300204

Hand Driver K2S K2L Plastic Casting Sleeve

Cat. No.

With Hex 501101

Without Hex 501102

L : 09 800912

L : 16 801612

For more info please refer to WWW.dentalis.us

36


Straight adaptor A especially design to facilitate the installation of the overdenture system on nonparallel implants, this type of adaptor has an upper cone that can solve the lack of parallelism. The impression-taking is performed over the installed adaptors The overdentnure system is screwed to the cone. Available in different heights Made of Titanium Alloy [Ti-6Al-4V]

Restorative Products

H

Cat. NO.

H:1mm 502001

H:2mm 502002

H:3mm 502003

H:4mm 502004

Implant Analog for Narrow Platform

Plastic Casting Sleeve

Cat. NO.

With Hex 501101

H:5mm 502005

Without Hex 501102

L:3mm 300203

600013

Multi Unit Angular Adaptor

Cat. NO.

17째 H:1.5 503171

30째 H:1.5 503301 To close the Abutment use Final Torqe :30Ncm

37


Ball Attachment Abutment The Ball Attachment abutment is use to supported implant retained overdentures. This type of abutment can connects a detachable prosthesis to an implant with the Metal Cap that is on the overdenture. It can provide solid stabilization, retention of the overdenture and tissue-supported with easy fast and reliable way. They are recommended for relatively parallel implants. The Ball Attachment abutments come with a Metal cap and silicon cap. Three 3 types of Silicon caps that are available in three level of hardness, 1-3, from the softest to the hardest. Ball Abutment may be use as indirect transfer impression. Ball Abutment Analogs on facing page are used for the production of a working cast. The Ball Attachment It made of Titanium Grade 5. The Metal cap is made of stainless steel.

Overdenture

Ball Attachment for Nerrow Platform Ă˜ 3mm-Code BAN

H

Cat. No.

H:1mm 451021

H:2mm 451022

H:3mm 451023

H:4mm 451024

Ball Attachment for D2 implant-Ă˜ 3 mm Code BAD

For more info please refer to WWW.dentalis.usa

Cat. H:1mm No. 451031

H:2mm 451032

H:3mm 451033

Silicon Cap

Cat. No.

Hard-SCH

461001

Regular-SCR

300102

Sofet-SCS

461003

H:4mm 451034

Metal Cup

Protective Disk

460000

300101

To close the Abutment use Final Torqe :30Ncm

38


BAR-Ball Attachment for Regular platform Ă˜ 3.5 mm

H

Cat. No.

H:1mm 452041

H:2mm 452042

H:3mm 452043

Silicon Cap

Overdenture

Cat. No.

Hard-SCH

461001

Regular-SCR

300102

Sofet-SCS

461003

H:4mm 452044

H:5mm 452045

H:6mm 452046

Metal Cup

Protective Disk

460000

300101

H:7mm 452047

H:8mm 452048

Hand Driver K2S K2L

L : 09 800912

Ball Attachment Analogs

L : 16 801612

39

All products are subject to change without notice.

Cat. 600013 No.

For more info please refer to WWW.dentalis

Used to represent the Ball Abutment Implant assembly in the working cast.Only used in conjunction with Ball Attachment Abutment


Locator Abutment Dentalis Locator Attachments is intended for use with partial dentures or full overdentures with more than two implants. This attachment abutment type can increases the available opportunities for removable implant prosthetics, through it’s low vertical height profile, range of divergence, dual retention, and self-aligning ability. This type of properties makes the Locator easy for patients to use, easily seat the overdenture without attaining accurate alignment of the attachment components. It is even possible to use them on implants with a divergence of up to 40º degrees. It also offers three options for the fabrication of a resilient attachment on an implant-supported cast alloy or milled titanium bar.

Cat. No.

H:0mm 470000

H:1mm 470001

H:2mm 470002

H:3mm 470003

Cat. No.

H:4mm 470004

H:5mm 470005

H:6mm 470006

H:7mm 470007

Silicon Cap set (0-10°)

Cat. 0-10°-1 No. 471001

0-10°-2 471002

Protective Disk

Cat. No.

473002

0-10°-3 471003

Overdenture

H

Silicon Cap set (10°-20°)

10°-20°-1 10°-20°-2 10°-20°-3 471001 472002 472003

Metal Cap

473001

Dentalis Bio Solution complies with ISO 13485, ISO 14001 and Council Directive 93/42/EEC

40


Analog & Transfer

Analog & Transfer

For the preparation of laboratory models. Impression Transfer (Impression copy). Hexagon Impression Transfer is made of stainless steel and available for Closed tray - round edges and short screw. Open tray - sharp edges and long screw. The function of an implant level impression is to exactly transfer to a laboratory model the position of the implant in relation to natural teeth or other implants as well as the soft tissue contours. An Implant Level impression can be takes at different stages during treatment and is dependent on Physician /operator preferences: At time of primary surgery – for one stage techniques, or to enable the delivery of a provisional crown at second stage surgery or at the second stage surgery. Impression Transfer closed-tray, transfer impression technique is designed to transfer the implant’s position and the soft tissue profile as well as the hex location, position, Indirect Transfers remain attached to the implants when the closed-tray impression is removed out from the mouth. The transfer hast to retrieve from the implant, mated to the related Implant Analog, and placed into its related impression hole. To fabricate a working cast containing a replica of the implant in the patient’s mouth, the impression is poured in dental stone. Implant-level open-tray, pick-up impression technique: Designed to position the transfer implant’s as well soft tissue profile and hex location, position, Direct Transfers are held firmly within the open-tray impression as it is removed from the mouth. Therefore, the central transfer screw should remove before the impression can be released out from the mouth. This transfer procedure requires a custom tray or modified stock tray with screw access holes in the areas occlusal to the implants. The Implant Analog is connected to the transfer embedded within the impression, then the impression is poured in dental stone to fabricate a working cast containing a replica of the implant in the patient’s mouth. Made of stainless steel.

Cat. No.

Cat. No.

41

Analog for Narrow Platform

Analog for Regular Platform

Analog for D2 Implant

Analog for Versatile One Piece

600003

600030

600013

600023

Analog for Ball Attachment

Implant Analog for Anti rotation Abutment

Implant Analog for Straight adaptor

Analog for One Piece Anatomic

600016

600017

600018

600023


Transfer

Cat. No.

Transfer , Impression for Regular Platform

H:9mm 611209

H:9mm 610103

H:15mm 611315

Transfer Screw

H:9mm 700035

H:15mm 700036

Analog & Transfer

Transfer , Impression for Narrow Platform

Clip Transfer

This one piece product was design to simplified the method of impression it’s intend of use is for places with a limited intermaxillary space for a driver like the back teeth where the lack of space does not allow both the screw and the driver to fit in. Suitable for closed tray method with higher precision and for parallel implants only. The Clip impression transfer is offering a quick impression with no affixing screw. It is not required to remove or to insert the transfer as it remains in the impression throughout the process. Note: The Clip Transfer doesn’t completely replace the use of standard transfer.

Clip Transfer

Cat. H:9mm No. 612409

H:15mm 612415

42


43


Surgical Instrumentation

Surgical Instrumentation

44


Drivers & Tools L

Surgical Instrumentation

801509

Stainles steel

K2S - Short Hand Driver to close abutment Hex Size : 1.2 L : 09

810912

Stainless steel

K2L - Long Hand Driver to close abutment Hex Size : 1.2 L : 16

811612

Stainless steel

K3S - Short Hand Driver to close abutment Hex Size :1.8 L : 09

820918

Stainless steel

K3L - Long Hand Driver to close abutment Hex Size : 1.8 L : 16

821618

Stainless steel

K4S - Short Hex Driver to close abutment with ratchet / Torque . Hex Size :1.2 L : 09

800912

Stainless steel

K4L - Long Hex Driver to close abutment with ratchet / Torque. Hex Size :1.2 L : 16

801612

Stainless steel

K5S - Short Hex Driver to close abutment with ratchet / Torque . Hex Size :1.8 L : 09

800918

Stainless steel

K5L - Long Hex Driver to close abutment with ratchet / Torque . Hex Size :1.8 L : 16

801618

Stainless steel

K6S - Short Hex Driver to Placing implants with internal Hex . Hex Size : 2.5 L : 09

800925

Stainless steel

K6L - Long Hex Driver to Placing implants with internal Hex . Hex Size :2.5 L : 16

801625

Stainless steel

K7 - Retrieving ScrewTo release structure from implant.

830001

Stainless steel

K8 - Short Adaptor inserting the implant using a hand piece

832420

Stainless steel

K8 - Long Adaptor inserting the implant using a hand piece

832425

Stainless steel

K9 - Adaptor For prosthetic accessories using a hand piece with torque

831221

Stainless steel

900004

Stainless steel

Drill Extension

45

Dentalis Bio Solutions USA, 9650 E 148th St, Noblesville, 46060, Indiana, USA

For more info please refer to WWW.dentalis.usa

K1L - Long Hand Driver to close abutment for Narrow platform Hex Size : 0.9 L : 16


Start Drill Guide Drill To mark out and create the insertion point penetrating cortex to evaluate bone quantity and quality

Cat. 900000 No.

Pilot Drill Optional drill to guide succeeding with twist drills, e.g. suitable to facilitate soft bone situation Cat. Ø 1.8 mm No. 900005

Twist drill

Twist drill

Twist drill

Twist drill

Twist drill

Twist drill

Twist drill

Twist drill

Cat. Ø 2.0mm No. 911620

Ø 2.5mm 911625

Ø 2.8mm 901628

Ø 3.2mm 901632

Ø 3.6mm 901636

Ø 4.1mm 901641

Ø 4.6mm 901646

Ø 5.2mm 901652

Ø 5.8mm 901658

Drilling depth The drilling depth is measured from the drill tip up to the indication line. the additional depth or tip height created by the point of the drill is 0.6 to 2.5 mm, depending on the diameter and type of drill. 5.2 mm

+0.9 mm

+1. mm

+1.2 mm

+1.35 mm

+1.6 mm

6.5mm

4.6 mm

8mm

4.1 mm

10mm

+0.8 mm

3.6 mm

11.5mm

+0.6 mm +0.7 mm

3.2 mm

13mm

2.0 mm 2.5 mm 2.8 mm

5.8mm

+2.5mm

3.5mm Ø2.5

* Internal irrigation drillis are available *

46

Surgical Instrumentation

Twist drill

16mm

Dentalis Bio Solution complies with ISO 13485 and Council Directive 93/42/EEC

Drills- External Irrigation


Short Drills External irrigation Twist drill

Twist drill

Twist drill

Twist drill

Ø 2 mm 901120

Ø 2.5 mm 901125

Ø 2.8 mm 901128

Ø 3.2 mm 901132

Ø 3.6 mm 901136

Ø 4.1 mm 901141

Ø 4.6 mm 901146

Ø 5.2 mm 901152

6.5mm

Twist drill

8mm

Twist drill

11.5mm 10mm

Twist drill

3.5mm Ø 2.8

Long Drills External irrigation Twist drill

Twist drill

Ø 2 mm 902020

Ø 2.4 mm 902024

Ø 2.8 mm 902028

Ø 3.2 mm 902032

Ø 3.6 mm 902036

Ø 4.1 mm 902041

10mm

Twist drill

13mm 11.5mm

Twist drill

16mm

Twist drill

18mm

Cat. No.

Twist drill

20mm

Surgical Instrumantetion

Cat. No.

Twist drill

3.5mm Ø 3.2

47


Ø 3.6mm 921628

Ø 4.2mm 921637

Ø 4.7mm 921640

Surgical Instrumentation

Conical Drill

6.5mm

Conical Drill

16mm

Cat. Ø 2.4mm No. 921622

Conical Drill

8mm

Conical Drill

13mm 11.5mm 10mm

Conical Drill

6.5mm

Ø 2.4 mm Ø 2.8mm 931624 931628

8mm

Ensures smooth and precise surgery Sharp tip blade-easy penetration Large chip spaces laser marking Biocompatible Free of metal

Cat. Ø 2 mm No. 931620

13mm 11.5mm 10mm

The innovative ceramic pilot drills are made high performance mix of Zirconia oxide and Alumina oxide. featuring an excellent cutting performance, reduce vibration, smooth operation, it offer the possibility of working without metal, thus offering biocompatible and antiallergenic operation, Corrosion free, wear resistance can be used between 50 to 100 drills .They are ideal suited for initial preparation of the implant site axis and depth high sharpness and optimal cutting efficiency, requires about half the torque of steel drills.

16mm

For more info please refer to WWW.dentalis.usa

Ceramic Drills

48


Counter Sink Purpose: Remove cortical bone at ridge crest to faclitate pressure-free seating of the implant collar *Site Specific Indicated when dense cortical bone is present at the crest * Rounded non-end cutting hubcenters drill in osteotomy *Used folowing the final width increasing drill for each implant

Surgical Instrumentation

Cat. Ø 3.75 mm No. 902020

Ø 4.2 mm 902024

Ø 4.7 mm 902028

Ø 5.5 mm 902032

Ø 6 mm 902036

Ø 6.5 mm 902041

Trephine Burs for harvesting bone and implant removal

49

6.5mm

8mm

10mm

Inner Ø 5mm Outer Ø 6mm 951660 11.5mm

Inner Ø 4mm Outer Ø 5mm 951650 13mm

Inner Ø 3mm Outer Ø 4mm 951640

16mm

Inner Ø 2mm Outer Ø 3mm Cat. 951630 No.


872832

873236

873643

874348

Straight Osteotomes Kit

2-2.8 Ø 872028

2.8-3.2 Ø 3.2-3.6 Ø 3.6-4.3 Ø 4.3-4.8 Ø 872832 873236 873643 874348

882028

882832

883236

883643

Angular Osteotomes Kit

2-2.8 Ø 882028

2.8-3.2 Ø 3.2-3.6 Ø 3.6-4.3 Ø 4.3-4.8 Ø 882832 883236 883643 884348 13mm 11.5mm 10mm 8mm 6.5mm 4mm

Cat. No. 872028

50

Surgical Instrumentation

Sinus Kit


Professional Implantology Tools Handle

Mallet

Ratchet Torque Ratchet Wrench

Surgical Instrumentation

Parallel Pin Kit

Purpose:Evaluation of osteotomy position and angle Provided straight or a 15° or 25° angle Used after Ø 2.0mm Starter Drill and Ø 2.5mm Depth Drill 9mm shank for radiographic evaluation of proxmimty to adjacent anatomy Hub diameter is 4.0mm Straight Parallel Pins

(2 per kit )

Tissue Punch Driver

Tissue Measuring Post

15° Angled 25° Angled Parallel Parallel Pins Pins (2 per kit )

(2 per kit )

Depth Gauge

Ø1.8

Ø2.4

Ø2.8

Ø3.2

Ø3.6

Ø4.1

Cat. 861821 862421 862821 863221 863621 864121 No.

51

6.5mm

8mm

10mm

11.5mm

13mm

Depth Gauge Kit


Dentalis Bio Solution complies with ISO 13485, ISO 14001 and Council Directive 93/42/EEC Canadian Medical Devices Regulation.

For USA Only: Federal Law restricts this device to sale by or the order of licensed dentist or physician All products are subject to change without notice. Some products may not be available in all markets Please contact your local Dentalis Office for current product assortment and availabilty

52


Dentalis Bio Solutions USA 9650 E 148th St Noblesville, 46060 Indiana, USA Phone: 317-214-7076 For more info please refer to WWW.dentalis.us or to your local distributor


Internal Hex & One PieceImplants