Skip to main content

Corrosion Protection n. 14 - January 2026

Page 11

WHAT'S NEW

Phosphate-free corrosion inhibitor protects hydrotested drinking water systems Drinking water storage tanks and the piping behind walls are

The protection of drinking water systems presented another

components that are generally out of sight and typically fall under

challenge, requiring the corrosion inhibitor to meet ANSI/NSF

the responsibility of plumbers and construction contractors.

Standard 61 for drinking water system components. Cortec® met

However, the fact that they are not visible does not mean corrosion

this challenge in 2023 with VpCI®-649 HP, a corrosion inhibitor

will ignore them: it can in fact compromise pipes and tanks

that, when added as a surface treatment to hydrotesting water

even before they are put into service. For this reason, Cortec®

at concentrations up to 3% and drained, is certified to meet

is encouraging contractors and plumbers to raise awareness of

ANSI/NSF Standard 61. This exciting breakthrough now allows

VpCI®-649 HP, a phosphate-free corrosion inhibitor designed to

contractors and plumbers to hydrotest potable water pipes and

provide protection during and after hydrotesting.

tanks without leaving them prone to corrosion during construction

Hydrotesting of drinking water piping, fittings, and vessels

waiting periods.

is a standard practice after installation and before initial

VpCI®-649 HP protects steel, copper, galvanized steel, and

commissioning, as well as after repairs and idle periods. This critical

aluminum above and below the water level, covering a broad range

step helps plumbers and contractors identify potential leaks

of drinking water systems. It does not contain nitrite, phosphate,

and confirm that the system will withstand operating pressure.

molybdenum, or chromate. Application can be confirmed with a

Unfortunately, the same water that confirms integrity also leaves

PTSA tracer. We all need drinking water. Drinking water systems

behind residual moisture that can cause corrosion problems before

need hydrotesting. Help contractors and plumbers avoid corrosion

tenants ever move into the structure and turn on the water.

problems by introducing them to a simple corrosion solution that

For years, Cortec® and other manufacturers have offered corrosion

protects during and after this critical phase.

inhibitors for hydrotesting oil and gas pipelines, as well as all types of pressure vessels.

www.cortecwatertreatment.com

DURABLE PROTECTION? EASY WITH OUR FLUIDIZED BED COATING SYSTEMS!

QUALITY AND INNOVATION BEYOND THE SURFACE O.M.SA. s.r.l. Via Cimabue, 16 | Fraz. MONTESIRO 20842 BESANA in BRIANZA (MB) | ITALY info@omsasrl.com | www.omsasrl.com


Turn static files into dynamic content formats.

Create a flipbook
Corrosion Protection n. 14 - January 2026 by ipcm® International Paint&Coating Magazine - Issuu