T1 Surge Protection Devices (1 pole) with very high impulsed current 50kA. References : 23101, 23102, for the protection against direct lightning strike with airterminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 50 kA Nominal current In 25 kA Protection level Up 1,2kV and 1,9kV Remote and optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23101

23102

Type of network

TT-TN-IT

TT-TN

Nominal voltage Un (VAC)

400

230

Arrester lightning voltage UC

440 VAC

335 VAC

Temporary overvoltage UT

Uc

> 400 VAC

Lightning test current, peak value limp (10/350μs)

50 kA

Protection Level Up (for limp)

1,8 kV

1,2 kV

Protection Level Up (for ln)

1,9 kV

1,2 kV

Specific energy / charge

625kJ/Ω / 25 As

Leakage current lpe (mA)

< 2.5

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Conductor cross section (Remote indicator contact)

1.5 mm² (stranded,solid)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection devices (1 pole) with very high impulsed current 35kA. References : 23103, 23104, for the protection against direct lightning strike with airterminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 35 kA Nominal current In 25kA Protection level Up 1,2kV and 1,9kV Remote and optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23103

23104

Type of network

TT-TN-IT

TT-TN

Nominal voltage Un (VAC)

400

230

Arrester lightning voltage UC

440 VAC

335 VAC

Temporary overvoltage UT

Uc

> 400 VAC

Lightning test current, peak value limp (10/350μs)

35 kA

Protection Level Up (for limp)

1,8 kV

1,2 kV

Protection Level Up (for ln)

1,9 kV

1,2 kV

Specific energy / charge

306 kJ/Ω / 17,5 As

Leakage current lpe (mA)

< 2.5

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Conductor cross section (Remote indicator contact)

1.5 mm² (stranded, solid)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection devices (1 pole) with high impulsed current 25kA. References : 23105, 23106, for the protection against direct lightning strike with airterminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 25 kA Nominal current In 25kA Protection level Up 1,3kV and 2kV Remote and optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23105

23106

Type of network

TT-TN-IT

TT-TN

Nominal voltage Un (VAC)

400

230

Arrester lightning voltage UC

440 VAC

335 VAC

Temporary overvoltage UT

Uc

> 400 VAC

Lightning test current, peak value limp (10/350μs)

25 kA

Protection Level Up (for limp)

1,8 kV

1,2 kV

Protection Level Up (for ln)

2 kV

1,3 kV

Specific energy / charge

155 kJ/Ω / 12,5 As

Leakage current lpe (mA)

< 2.5

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Conductor cross section (Remote indicator contact)

1.5 mm² (stranded, solid)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection devices with high impulsed current 25kA. References : 23120, 23121, 23122, 23123, 23124, for the protection against direct lightning strike with air-terminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 25 kA Nominal current In 25kA Protection level Up 1,5kV and 2,2kV Remote and optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23120

23121

23122

23123

23124

Type of network

TT-TN L-N

TT-TN 3*L

TT-TN-IT 3*L

TT-TN-IT 3*L+N

TT-TN 3*L+N

Number of modules

2

3

8

8

4

Nominal voltage Un (VAC)

230

400

230

Arrester lightning voltage UC

335 VAC

440 VAC

335 VAC

Temporary overvoltage UT

> 400 VAC

Uc

> 400 VAC

Lightning test current, peak value limp (10/350μs)

25 kA

Protection Level Up (for limp)

1,2 kV

Protection Level Up (for limp)

1,5 kV

1,8 kV

1,2 kV

2,2kV

1,5 kV

Specific energy / charge

155 kJ/Ω / 12,5 As

Leakage current lpe (mA)

< 2.5

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Conductor cross section (Remote indicator contact)

1.5 mm² (stranded, solid)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection devices with high impulsed current 25kA. References : 23107, 23108, for the protection (common mode and differential) against direct lightning strike with air-terminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 25 kA Nominal current In 25kA Protection level Up 1,2kV Remote and optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHICAL DATA References

23107

23108

Type of network

TT-TN L+N

TT-TN 3*L+N

Nominal voltage Un (VAC)

230

230

Arrester lightning voltage UC

335 VAC

335 VAC

Temporary overvoltage UT

> 400 VAC

> 400 VAC

Lightning test current, peak value limp (10/350μs)

25 kA

Protection Level Up (for limp)

1,2 kV

Protection Level Up (for ln)

1,5 kV

1,2 kV 1,5 kV

Specific energy / charge

156 kJ/Ω / 12,5 As

Leakage current lpe (mA)

-

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Conductor cross section (Remote indicator contact)

1.5 mm² (stranded, solid)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection Devices with standard impulsed current 12,5 kA. References : 23109, 23110, 23111, 23112, for the protection against direct lightning strike with air-terminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 12,5 kA Nominal current In 20kA Protection level Up 1,2kV and 1,7kV Optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23109

23110

23111

23112

Type of network

TT-TN-IT 3*L+N

TT-TN-IT L+N

TT-TN L+N

TT-TN 3*L+N

Nominal voltage Un (VAC)

400

400

230

230

Arrester lightning voltage UC

440 VAC

440 VAC

335 VAC

335 VAC

Temporary overvoltage UT

Uc

Uc

> 400 VAC

> 400 VAC

Lightning test current, peak value limp (10/350μs)

12,5 kA

12,5 kA

Protection Level Up (for limp)

<1,7 kV

<1,2 kV

Protection Level Up (for ln)

<1,8 kV

<1,5 kV

Specific energy / charge

39 kJ/Ω / 6,25 As

Leakage current lpe (mA)

< 2,5

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection devices with standard impulsed current 12,5 kA. References : 23113, 23114, 23115, for the protection (common mode and differential) against direct lightning strike with air-terminal and indirect lightning strike of 1 phase and 3phases power supply network installations located for sites with high keraunic level. • • • • •

Surge arrester type 1 Iimp 12,5 kA Nominal current In 20kA Protection level Up 1,2kV Optical fault indicator contact EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23113

23114

23115

Type of network

TT-TN 3*L+N

TT-TN L+N

TT-TN 3*L+N

Nominal voltage Un (VAC)

230

230

230

Arrester lightning voltage UC

335 VAC

335 VAC

335 VAC

Temporary overvoltage UT

> 400 VAC / Uc

> 400 VAC / Uc

> 400 VAC / Uc

Lightning test current, peak value limp (10/350μs)

12,5 kA / 50 kA

12,5 kA / 50 kA

12,5 kA / 50 kA

Protection Level Up (for limp)

1,2 kV

1,2 kV

1,2 kV

Protection Level Up (for ln)

<1,5 kV

<1,5 kV

<1,5 kV

Specific energy / charge

39 kJ/Ω / 6,25 As

Leakage current lpe (mA)

100 A

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.250 A gG/gL

Max. required backup fuse Icc>25kA

max.125 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Remote indicator contact Conductor cross section (stranded, solid)

No -

No -

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

Yes 1.5 mm²

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Pluggable Surge Protection Devices with standard impulsed current 12,5 kA. References : 23116, 23118, for the protection against direct lightning strike with airterminal and indirect lightning strike of 1 phase and 3-phases power supply network installations located for sites with high keraunic level. • • • • • •

Surge arrester type 1 Iimp 12,5 kA Nominal current In 20kA Protection level Up 1,4kV and 1,8kV Remote and optical fault indicator contact 1 pluggable pole EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23116

23118

Type of network

TT-TN-IT

TT-TN

Nominal voltage Un (VAC)

400

230

Arrester lightning voltage UC

440 VAC

335 VAC

Temporary overvoltage UT

Uc

Uc

Lightning test current, peak value limp (10/350μs)

12,5 kA

12,5 kA

Nominal current In (8/20μs)

20 kA

20 kA

Protection Level Up (for limp)

-

-

Protection Level Up (for ln)

1,8 kV

1,4 kV

Specific energy / charge

39 kJ/Ω / 6,25 As

Leakage current lpe (mA)

< 2,5

Response time (ns)

< 25

Max. required backup fuse Icc≤25kA

max.160 A gG/gL

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Remote indicator contact Conductor cross section (stranded, solid)

1.5 mm² (stranded, solid)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

Replacement plug

Reference 23117

Reference 23119

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com


T1 Surge Protection Devices (1 pole) with very high standard impulsed current 50kA or 100kA. References : 23129, 23130, for the protection against direct lightning strike with airterminal and indirect lightning strike of N-PE line of power supply network installations located for sites with high keraunic level.

• • • • •

Surge arrester type 1 Iimp 50 kA / 100kA Nominal current In 50kA / 100kA Protection level Up 1,2kV Optical fault indicator contact NF EN 61643-11 / IEC 61643-1

TECHNICAL DATA References

23129

23130

Type of network

TT-TN

TT-TN

Nominal voltage Un (VAC)

230

230

Arrester lightning voltage UC

255

255

Temporary overvoltage UT

Uc

Uc

Lightning test current, peak value limp (10/350μs)

50 kA

100 kA

Protection Level Up (for limp)

-

-

Protection Level Up (for ln)

1,2 kV

1,2 kV

Specific energy / charge

625kJ/Ω / 25As

2,5MJ/Ω / 50As

Response time (ns)

< 100

Follow current extinguishing capability

> 100A rms

Short circuit resistance ICC with max. backup fuse (effective)

25 kA at 50Hz

Conductor cross section L; N; PE

4-35 mm² (stranded : 25 mm² max.)

Ambient temperature (operation)

-20°C / +80° C

Degree of protection / Mounting type

IP20 / Rail din

A France Protection product

FRANCE PARATONNERRES   ­­­    ZA de Clocher 23000 Guéret  ­­­  FRANCE Tel : 33 555 523 933    ­­­   Fax : 33 555 819 982 web : http:// www.france­paratonnerres.com ­­­ e­mail : rx@france­paratonnerres.com

TVSS Nivel 1  

tipo de tvss

Read more
Read more
Similar to
Popular now
Just for you