New Curved & Tapered Panels

InterlockÂŽ Standing Seam Specification Manual


Interlock® Standing Seam Our Standing Seam aluminum roofing can be installed on new construction or applied over existing roofs. All trims and caps are designed to ensure an integrated weather-proof roof. Runs are vertical, manufactured to length in continuous form to a maximum length of 26’.

It is the responsibility of architects, builders and roof installers to ensure that all construction bylaws and building codes are adhered to.

Gage of aluminum .028” (.71mm) coated with:

Interlock ® aluminum exclusively protected fo Alunar® embedded w surface protector for ulti

Embedded with

17” (43.2 cm) Panel width 26’ Maximum Length

Leveling Underlayment Underlayment

1” Seam Height

Roof Surface 1/2” Sheathing

Sliding clip

1

Description

Standing Seam Lock with clip Fixed clip


Interlock® Standing Seam Like all of our products, our Standing Seam is coated with the Alunar® Coating System, embedded with Teflon™ surface protector, to provide an extremely durable and attractive surface. The panels are roll formed with a ribbed contour to give added strength. Panels are clipped and fastened in place with the next panel overlapped and securely lock-formed in place. Roof Slope Minimum 3:12 when installed with an ice & water underlayment or 4:12 minimum with standard underlayment.

Interlock® Standing Seam has many advantages when compared to other roofing products. • Lifetime Limited Warranty • Energy Star® Rated (U.S. Only) • Curbside appeal • Weather and wind resistant • Low maintenance • Available in many designer colors • Lightweight • Superior strength / Durability

Weight

Application

Our Standing Seam weighs considerably less than most other types of roofing systems. No special preparation is needed, resulting in less structural cost.

Leveling underlayment may be used to reduce surface imperfections. Panels are clipped and fastened with screws with the next panel being lock-formed in place.

• Alunar® Coating embedded with Teflon™ surface protector • Non-combustible “Class A” Fire Rated available • No cracking or splitting • Full interlocking connection system • Hail Resistance; Meets UL Standard 2218 Class 4, Impact Standard for Impact Resistance

Sheathing

Underlayment

Sheathing for the roof should be 1/2” minimum or tightly fitting boards.

The entire roof area should be covered (prior to panel application) with synthetic roofing underlayment.

Clip

Standing Seam Panel Underlayment

Starter Trim Leveling Underlayment

2

Description

Sheathing


Starter Strip The manufacturing characteristics of the Starter Strip provides a water barrier which prevents water back-up.

4 5/8”

Starter Strip Profile

1/2”

1” Tapered

3/8” 1/2”

2 1/8”

Specialty Panels New options available for Standing Seam are Curved and Tapered panels for custom roofing features.

Curved

3

Components


Gable End An inner gable is installed and a gable end trim is then applied over top to form a protective cap.

Standing Seam Panel

Standing Seam Panel

2”

Backpan

5”

31/4”

4”

10”

5”

Sid

Backpan Inner Gable

4”

10”

Gable End Trim

Chimney / Skylight Collar

Provides a weather-tight seal around chimneys. Roof panels are secured around the chimney and a collar is cut into the brick and mortar, covering the roof panels.

Backpan

5” 3/8”

1”

Collar

10”

3/8”

4”

Endwall 2

1”

8”

1”

Collar 1/2” 3/8”

1/2”

Sidewal

4”

Endwall

1/2”

2

8”

1”

1/2” 3/8”

Sidewall

4”

2 1/2” 1”

4

1/2”

Collar

3/8”

1”

Endwall

8”

2 1/2”

Components 1/2” 3/8”

1”

1/2”

4”

1/2”

1/2”

1”

4”


Valley Trim Provides smooth, obstruction-free path for precipitation. Roof panels are trimmed and folded inside the locking joint to form a solid weather-proof unit. This specially designed trim is manufactured in 10’ lengths. Wider valleys may be used in areas with high levels of snow.

4”

6”

1”

30° 1” 1”

Two Piece Ridge Cap Standing Seam Panel Interlock’s Ridge Cap Has Been Specially Designed To Not Have Fasteners That Will Allow For Water Stitch Penetration. Screw Bread Panned Panel

Vented Closure Sheathing 1/2” Minimum

5

Components

Drag-Load Fastener

Leveling Underlayment Underlayment


Two Piece Ridge Cap

Endwall

Valley Trim Sidewall Flashing

2 Piece Gable Trim

Sheathing: 1/2�

Roof Panels

Underlayment

Starter Strip Leveling Underlayment

6

Application


Color Guide Interlock® roofs are exclusively protected for a lifetime by the Alunar® Coating System embedded with TEFLON™ surface protector.

Solid Copper

Copper Penny

Black

Deep Charcoal

Colonial Brown

Tudor Brown

Musket Grey

Hunter Green

Tile Red

The Alunar® Coating System provides homeowners the ultimate in durability and protection from stains, moisture and organic debris.

Embedded withwith Embedded

® ® Interlock aluminum roofs areare Interlock aluminum roofs exclusively protected for for a lifetime by by exclusively protected a lifetime ® ® embedded withwith TEFLON™ Alunar Alunar embedded TEFLON™ surface protector for for ultimate durability. surface protector ultimate durability.

(U.S. Only)

vary from represented shown on manual. Installation methods may vary by structure, region, climate, and local building codes. Certain variables and factors

NORTH/EAST ROOFING CONTRACTORS ASSOCIATION

(U.S. Only)

1.866.354.6262 Solid Copper

Copper Penny

NAT-127679-1 / 36156-1 / 34864-1

9969 River Way, Delta, BC V4G 1M8

Black

Deep Charcoal

The ENERGY STAR name and the ENERGY STAR symbol are registered trademarks of the United States Environmental Protection Agency and are used with permission. When installed properly, this

Profile for Interlock Metal Roofing

Interlock® Standing Seam Spec Manual  

Classic weather-tight panel roofing system.

Interlock® Standing Seam Spec Manual  

Classic weather-tight panel roofing system.