1 minute read

International Journal for Research in Applied Science & Engineering Technology (IJRASET)

ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538

Advertisement

Volume 11 Issue II Feb 2023- Available at www.ijraset.com

Result: Max dry density ( ρd) = 1.61 gm./cm3& Optimum moisture content = 25.9%

5) 5standard Proctors Compaction Test Of Sample With 0.10% Terrasil, 10% RHA AND 20% FA:

The effect of 0.10% Terrasil, 10% RHA and 20% FA dose on Standard proctor compaction test of sample of examining soils has been shown in Table .14.

Table no.: .14 Standard proctor compaction test of sample with 0.10% Terrasil, 10% RHA and 20% FA Test

E. Permeability of Soil By Variable Head Permeameter

The variable head Permeameter is used to measure the permeability of relatively less previous soils. The coefficient of permeability is given by

K=. log cm/sec

Where h1 = initial head: h2 = final head; t = time interval; a = cross sectional area of the standpipe; A =cross sectional area of the specimen, L = length of specimen.

This article is from: