Issuu on Google+

Date: 28.10.13 Phase: Concept phase Building component journal: story partition

BUILDING COMPONENT, MATERIAL OR APPLIANCE LOCATION and QUALITY

Story partition in extention

Drawing/sketch:

Acc. To BR10-15 regulations:

Easy-joist floor system

REQUIERED PROPERTIES

ACTUAL PROPERTIES

U-value (W/m K)

2

BR15-0,40 W/m2K

0,22 W/m2K

Sound, Rw (dB)

No requirements

Fire (class;minutes)

REI 60-A2-s1,d0

60 minutes

Sizes(W,H,L/D)

Min. Thickness: mm H:max. 3050mm L: max 10000mm

Thickness: 348.5 mm

Other:Allowable Air Water NFRC UFactor CRFframe STC 0. 06 cfm/sqft at 6.24 psf 15 psf 0. 18 to 0. 52 BTU/hr.sqft.°F 78 to 83 31 to 49 (est.)

Acc.client demands and specific project properties:

COMPOSITION

• • • • •

Linoleum 2.5 mm Clay 2 mm 15 mm OSB; Min 254 mm easy-joist/ min 35x97 mm Strongback/ 100 mm rockwool cladding roll; 2x15 mm plasterboard

RRICE ADVANTAGES

DISADVANTAGES REFERENCES

Combining the benefits of sustainable, kiln dried, stress graded timber with the stiffness of a metal web construction, easi-joist® provides customers with lightweight floor beams, engineered to precise dimensions that allow for easy installation of services such as pipes, cabling, trunking and ducts in the floor zone. Installation benefits are immediately evident, reducing the amount of time other trades spend on site and removing all site joist modification work. The metal web floor system allows for the installation of a rigid Strongback. This reduces vibration and improves the overall performance of the floor.

Maximum sizes: 219x5225 mm, 254x5675 mm, 304x6325 mm, 417x7075 mm http://www.wolfsystem.co.uk •


Date: 28.10.13 Phase: Concept phase Building component journal:

BUILDING COMPONENT, MATERIAL OR APPLIANCE LOCATION and QUALITY

(21) External curtain wall

Drawing/sketch:

Acc. To BR10-15 regulations:

HP-WallTM Series high performance curtainwall with up to a four-level thermal barrier system providing the ultimate in thermal and acoustical performance. REQUIERED PROPERTIES

ACTUAL PROPERTIES

0.08 W/m2K

Sound, Rw (dB)

BR15-0,12 W/m2K No requirements

Fire (class;minutes)

REI 60-A2-s1,d0

REI 60 A2 – s1, d0

Sizes(W,H,L/D)

Min. Thickness: mm H:max. 3050mm L: max 10000mm

Thickness: 181mm

2

U-value (W/m K)

Other:Allowable Air Water NFRC U-Factor CRFframe STC 0. 06 cfm/sqft at 6.24 psf 15 psf 0. 18 to 0. 52 BTU/hr.sqft.°F 78 to 83 31 to 49 (est.)

Acc.client demands and specific project properties:

COMPOSITION RRICE ADVANTAGES

• • • • • • • • • • • •

DISADVANTAGES REFERENCES

Best-in-class thermal performance lowers operating costs and reduces necessary HVAC capacity Condensation resistance for high humidity occupancies 2 ½" exterior sight line Accepts triple insulating glass Proven pressure-plate field glazing system design Multi-level thermal barrier Captured or vertical structural glazed Screw-spline construction Available with interior access doors and between-glass blinds Exterior sun shades and interior light shelves available Recycled aluminum framing available upon request NFRC CMA-listed


Date: 30.10.13 Phase: Concept phase Building component journal: (27) Roof (Extension part)

BUILDING COMPONENT, MATERIAL OR APPLIANCE LOCATION and QUALITY

Roof covering the extension part. Consists of prefabricates steel roof elements. 2 Total area: 279.6 m 0 Slope: 1.4 Acc. To BR10-15 REQUIERED PROPERTIES ACTUAL PROPERTIES regulations:

Drawing/sketch:

2

2

2

U-value (W/m K)

0.08 W/m K

0.08 W/m K

Sound, Rw (dB)

No requirements

-

Fire (class; minutes)

REI 60-A2-s1,d0

REI 60 A2 – s1, d0

Sizes(W,H,L/D)

Min. Thickness: 150 mm

Thickness: 650 mm

Other: *Roofs must be built so as to allow rain and melt water from snow to run off in an appropriate manner. Roof water must be discharged into drains via gutters and/or rainwater downpipes. This will normally be achieved if the roof surface has a gradient of more than 1:40, corresponding to 2.5 cm per metre.

The smallest 0 permitted slope: 1.4 , which is also going to be used.

Acc. to client demands and specific project properties: -Steel Sheet covering (45 mm in height) -10 mm Roofing felt -20 mm compressed insulation (Rckwool TF board/Paroc Roof Board) -Galvanized corrugated sheet (Steel Decking) -Skandek GreenLine beam -Insulation (600 mm)- (Rockwool Flexibatts/Paroc Roof Batts) -PE water vapour barrier -20 mm compressed insulation (Rckwool TF board/Paroc Roof Board) -Ceiling finish (2x 12.5 mm plasterboard + paint) RRICE -

COMPOSITION

ADVANTAGES

DISADVANTAGES

REFERENCES

• • • •

25 year warranty Easy and fast installation Sufficient energy requirements for energy class 2015

CE Marked product

-Price

Skandek.dk


Date: 28.10.13 Phase: Concept phase Building component journal:

BUILDING COMPONENT, MATERIAL OR APPLIANCE LOCATION and QUALITY

(21) External Steel-Frame wall with wood finish

Drawing/sketch:

Acc. To BR10-15 regulations:

REQUIERED PROPERTIES

ACTUAL PROPERTIES

U-value (W/m K)

2

BR15-0,12 W/m2K

0.10 W/m2K

Sound, Rw (dB)

No requirements

-

Fire (class;minutes)

REI 60-A2-s1,d0

REI 60 A2 – s1, d0

Sizes(W,H,L/D)

No requirements

Thickness: 422 mm

Acc.client demands and specific project properties:

Steel building system with light clothing such as wood, steel or other facade panels. Where used exterior rain screen with open joints, we recommend using Aqua Panel outdoor as wind barrier. by light coverings followed the manufacturer's instructions for ventilated cavity (usually 25 mm) detail shown as load-bearing wall COMPOSITION Wood covering: 30mm Ventilation cap: 25mm Clima boards: 2x9mm Rigid insulation: 2x 125mm Damp-proof membrane Rigid insulation: 75mm Plasterboards: 2x 12mm RRICE Will be presented in Tender package. ADVANTAGES

DISADVANTAGES

REFERENCES

• Steel is strong and durable, offering long lasting structural integrity. • Steel framing won't warp, twist or shrink. • Non-combustible, steel framing offers a significant reduction in flammable material. • Steel roof, wall and floor framing is 100 per cent termite proof. • Steel Framing is relatively lightweight, reducing transport and installation costs. • With an excellent strength to weight ratio, steel framing allows for greater design flexibility. •Reduced onsite cutting minimises installation time and material wastage.


System Multi Rule S450 - Classic Board Our unique sound rule that combines superior audio performance with good ergonomics for the operator. This leads to thin wall structures and the need for fewer wall types. Assumptions: The wall maxhöjder are calculated based on a utböjningskrav on L/300 at a horizontal line load of 0.5 kN / m applied to the wall half height. The assumption that the entire structure interacts apply. For higher wall height contact Knauf Danogips. Space within for the elderly at home in activities for the elderly as well as from sanitary and storage to housing. Audio Class A: R'w = 61dB, Audio Class B: R'w = 57dB and sound class C: R'w = 53 dB. Refers homes Index 100 = E MR 450 70/70 A / A M0 (only material cost excluding screw and possible acoustic sealant) M90 = 2 x 45 mm M140 = 2 x 70 mm M190 = 2 x 95 mm

System Multiregel s450 - Classic Board Vår unika ljudregel som förenar förstklassiga ljudprestanda med god ergonomi för montören. Detta leder till tunnare väggkonstruktioner samt behov av färre väggtyper. Förutsättningar: Väggarnas maxhöjder är beräknade utifrån ett utböjningskrav på L/300 vid en horisontell linjelast på 0,5 kN/m applicerad på väggens halva höjd. Antagandet att hela konstruktionen samverkar gäller. Vid behov av högre vägghöjd kontakta Knauf Danogips. Utrymme inom särskilda boendeformer för äldre till bostad inom särskilda boendeformer för äldre samt från hygienrum och förråd till bostad. Ljudklass A: R´w = 61dB, Ljudklass B: R´w = 57dB samt ljudklass C: R´w = 53 dB. Avser bostäder Index 100 = E MR 450 70/70 A/A M0 (avser endast materialkostnad exkl skruv och ev akustisk tätmassa) M90 = 2 x 45 mm M140 = 2 x 70 mm M190 = 2 x 95 mm


Bcj