Page 1


LOCATION: NATURAL PARK OF THE EBRE RIVER DELTA

DEC3 station

InGOS General Assembly Bremen, 11th-14th March 2013

2


CHARACTERISTICS OF THE DEC3 STATION Ebre river Delta (DEC3 Station) Location (surface)

Natural Park of the Ebre river delta (8445 ha)

Closest village

Deltebre (6.7 km SW of the station) with 12300 inhabitants

Climate

Typical mediterranean

Soil

Sandy and silty

Characteristics of the site

• 300 km2 of rice fields, flooded during some periods of the year (rice cultivation process) • Geographical position influenced by the Continent as well as by the Mediterranean sea • Very humid area

InGOS General Assembly Bremen, 11th-14th March 2013

3


METEROLOGICAL DATA AT DEC3

2.36% H2O

1.22% H2O

N wind from the continent

NW wind from the Ebre river

NE and E wind from the Mediterranean sea

InGOS General Assembly Bremen, 11th-14th March 2013

4


FOOTPRINT AT DEC3

HYSPLIT

FLEXPART

InGOS General Assembly Bremen, 11th-14th March 2013

5


EQUIPMENTS AND MEASUREMENTS Young Equipments Atmospheric Pressure (Young 61302v) Rainfall (Young 52202)

Air inlet (10 m height a.g.l.)

2D Anemometer WindSonic232 Wind Speed (1 Hz) Wind Direction (2D) (1 Hz) Vaisala HMP110 Sensor Temperature and HR Campbell CR1000 Datalogger Recording data system

InGOS General Assembly Bremen, 11th-14th March 2013

6


EQUIPMENTS AND MEASUREMENTS Picarro Analyzer G2301 [CO2], [CH4], [H2O] (1 measurement every 5 seconds) (C-12) ARMON for 222Rn measurements [Rn-222] (1 measurement every hour) Modified Gas Chromatograph 6890N Agilent [CO2], [CH4], [CO], [N2O], [SF6] (1 measurement every approx. 15 minutes)

InGOS General Assembly Bremen, 11th-14th March 2013

7


AIR INLET DRYING SYSTEM 

Pressure sensor

 Pressure regulator

Electrovalves ON-OFF

High Pressure

GC System

Refrigerator 1ºC

Water removal

Pressure Buffer 0.7L

Cryocooler -70ºC

Radon System

InGOS General Assembly Bremen, 11th-14th March 2013

PICARRO Analyser PICARRO PUMP

8


SCHEME OF THE MODIFIED GC AGILENT 6890N

N2O and SF6

CO, CH4 and CO2

Based on van der Laan et al. (2009) configuration

InGOS General Assembly Bremen, 11th-14th March 2013

9


TYPICAL CHROMATOGRAM AND RUN TIME Chromatogram

N 2O

? -ECD μ-ECD SF 6

FID CH 4 1

CO

CH 4 2

CO 2

Run Time mins 0.00 V5 ON V8 ON V1 ON

3.05 V7 Next

3.60 V4 ON V6 ON V8 OFF

5.20 4.92 V6 OFF V2 ON

5.84 V3 ON 6.00 V1 OFF

6.75 V5 OFF

8.90 8.88 V2 OFF V3 OFF V4 OFF

AUX AUX # 4 78psi 8.00 mins AUX # 3 and # 5

60psi

8.00 mins

32 psi P Time ( mins )

0.22 0.03 0.34

InGOS General Assembly Bremen, 11th-14th March 2013

8.22 8.47 8.90 8.34 8.65

10


CALIBRATION STRATEGY • • • •

A working tank (WT) is used: WT - Sample – WT - Sample – etc. 6 working standards (MPI cylinders) used for calibration Currently, calibration every 2.2 days: Tests for lower frequency needed (1 per week?) A target cylinder (Trg) is run three times per day (MPI cylinder) CH4 (ppm)

CO (ppb)

N2O (ppb)

CO2 (ppm)

SF6 (ppt)

WS MPI 1

1.698

80.322

309.616

369.954

9.621

WS MPI 2

1.797

140.287

318.08

385.083

9.343

WS MPI 3

1.902

195.936

321.961

399.411

9.301

WS MPI 5

2.098

314.501

332.053

429.93

8.83

WS MPI 6

2.295

316.258

336.116

449.793

9.021

WS MPI 7

2.479

474.744

343.554

507.908

16.89

WT (MPI 4)

1.998

252.967

327.941

414.567

9.929

Trg (MPI 3)

1.902

195.936

321.961

399.411

9.301

WT (commercially available)

1.867

157.443

318.029

-

-

Trg (MPI 3)

1.902

195.936

321.961

399.411

9.301

InGOS General Assembly Bremen, 11th-14th March 2013

PERIOD 1: Oct. 2012 – Nov. 2012 PERIOD 2: Jan. 2013 – Feb. 2013

11


CH4, CO2, CO, N2O, SF6 CONTINOUS MEASUREMENTS WITH GC: ATMOSPHERIC DATA

The system had to be stopped due to a problem with the pump

InGOS General Assembly Bremen, 11th-14th March 2013

12


CH4, CO2, CO, N2O, SF6 CONTINOUS MEASUREMENTS WITH GC: ATMOSPHERIC DATA

Invalid values

The system had to be stopped due to a problem with the pump

InGOS General Assembly Bremen, 11th-14th March 2013

13


CH4, CO2, CO, N2O, SF6 CONTINOUS MEASUREMENTS WITH GC: ATMOSPHERIC DATA

The system had to be stopped due to a problem with the pump

InGOS General Assembly Bremen, 11th-14th March 2013

14


CH4, CO2, CO, N2O, SF6 CONTINOUS MEASUREMENTS WITH GC: ATMOSPHERIC DATA

The system had to be stopped due to a problem with the pump

InGOS General Assembly Bremen, 11th-14th March 2013

15


CH4, CO2, CO, N2O, SF6 CONTINOUS MEASUREMENTS WITH GC: ATMOSPHERIC DATA

The system had to be stopped due to a problem with the pump

InGOS General Assembly Bremen, 11th-14th March 2013

No SF6 value

16


CH4, CO2, CO, N2O, SF6 CONTINOUS MEASUREMENTS WITH GC: TARGET RESULTS

(assigned – measured) values

InGOS General Assembly Bremen, 11th-14th March 2013

17


CO2 PICARRO MEASUREMENTS

CO2 Target measurements: 1 every 23h during 20 min Precision (repeatability): 0.028 ppm Accuracy: 0.045 ppm

InGOS General Assembly Bremen, 11th-14th March 2013

Calibration: 4 Working Standards Every 20 days Each WS twice 20 minutes duration each analysis

18


CH4 PICARRO MEASUREMENTS

CH4 Target measurements: 1 every 23h during 20 min

Precision (repeatability): 0.26 ppb Acuracy: 0.8 ppb

InGos General Assembly Bremen, 11th-14th March 2013

Calibration: 4 Working Standards Every 20 days Each WS twice 20 minutes duration each analysis

19


XIC3

GC (CO2, CH4, N2O, CO, SF6) and Radon measurements Equipment under calibration and adjustments Site inaguration: April 2013

InGOS General Assembly Bremen, 11th-14th March 2013

21


GRAZALEMA

Site under construction GC data hopefully available on May-June 2013

InGOS General Assembly Bremen, 11th-14th March 2013

22


LA MUELA

GHG measurements since 2006 For GC measurements investment is needed: building a new container, renting of placement, standards

InGOS General Assembly Bremen, 11th-14th March 2013

23


IC3 ClimaDat TEAM

InGOS General Assembly Bremen, 11th-14th March 2013

24


Profile for Institut Català de Ciències del Clima

InGos ClimaDat  

InGos ClimaDat

InGos ClimaDat  

InGos ClimaDat

Advertisement