Page 1

HECTOR VILL AGRAN ARCH | | TECH


The Glass Farmhouse Condominium 138-60 Brookville Boulevard

31 Walton Street 221 Spencer Street 16 Bartlett Street

25 Arleigh Road 75-16 Rockaway Blvd CPLDC Chinatown Gateway

HV - Resume | 15

‡ ‡ ‡

MODELING VISUALIZATION | P. 11

‡ ‡ ‡

BIM | P. 5

‡ ‡

CADD | P. 1

CONTENT


STANDARD INSPECTION/TEST REFERENCE (SEE ECC CHAPTER 6) OR OTHER CRITERIA IIA

ENVELOPE INSPECTIONS

IIA2

INSULATION PLACEMENT AND R-VALUES

APPROVED CONSTRUCTION DOCUMENTS

IIA3

FENESTRATION THERMAL VALUES AND PRODUCT RATINGS

IIA6

SEALING AND INSULATION - VISUAL

IIB

ECC OR OTHER CITATION

INSPECTION DESCRIPTION

303.1, 303.1.1, 303.1.2, 502.1, 502.2; ASHRAE 90.1 - 5.5, 5.6 OR 11; 5.8.1

INSTALLED INSULATION FOR EACH COMPONENT OF THE CONDITIONED SPACE ENVELOPE AND AT JUNCTIONS BETWEEN COMPONENTS SHALL BE VISUALLY INSPECTED TO ENSURE THAT THE R-VALUES ARE MARKED, THAT SUCH R-VALUES CONFORM TO THE R-VALUES IDENTIFIED IN THE CONSTRUCTION DOCUMENTS AND THAT THE INSULATION IS PROPERLY INSTALLED. CERTIFICATIONS FOR UNMARKED INSULATION SHALL BE SIMILARLY VISUALLY INSPECTED.

APPROVED CONSTRUCTION DOCUMENTS; NFRC 100, NFRC 200

303.1, 303.1.3; 502.3; ASHRAE 90.1 - 5.5, 5.6 OR 11; 5.8.2

U-FACTORS AND SHGC VALUES OF INSTALLED FENESTRATION SHALL BE VISUALLY INSPECTED FOR CONFORMANCE WITH THE U-FACTORS AND SHGC VALUES IDENTIFIED IN THE CONSTRUCTION DRAWINGS BY VERIFYING THE MANUFACTURER'S NFRC LABELS OR, WHERE NOT LABELED, USING THE RATINGS IN ECC TABLES 303.1.3(1), (2) AND (3). WHERE ASHRAE 90.1 IS USED, VISIBLE LIGHT TRANSMITTANCE VALUES SHALL ALSO BE VERIFIED.

APPROVED CONSTRUCTION DOCUMENTS ASTM E283 ASTM E2178 ASTM E2357

502.4.3, 502.4.7; ASHRAE 90.1 - 5.4.3.1

OPENINGS AND PENETRATIONS IN THE BUILDING ENVELOPE, INCLUDING SITE-BUILT FENESTRATION AND DOORS, SHALL BE VISUALLY INSPECTED TO VERIFY THAT A CONTINUOUS AIR BARRIER AROUND THE ENVELOPE FORMS AN AIR-TIGHT ENCLOSURE. THE PROGRESS INSPECTOR SHALL VISUALLY INSPECT TO VERIFY THAT MATERIALS AND/OR ASSEMBLIES HAVE BEEN TESTED AND MEET THE REQUIREMENTS OF THE RESPECTIVE STANDARDS, OR THAT THE BUILDING IS TESTED AND MEETS THE REQUIREMENTS OF THE STANDARD, IN ACCORDANCE WITH THE STANDARD(S) CITED IN THE APPROVED PLANS..

MECHANICAL AND SERVICE WATER HEATING INSPECTIONS

IIB3

HVAC, SERVICE WATER HEATING AND POOL EQUIPMENT SIZING AND PERFORMANCE

APPROVED CONSTRUCTION DOCUMENTS

503.2, 504.2, 504.7; ASHRAE 90.1 - 6.3, 6.4.1, 6.4.2, 6.8; 7.4, 7.8

EQUIPMENT SIZING, EFFICIENCIES AND OTHER PERFORMANCE FACTORS OF ALL MAJOR EQUIPMENT UNITS, AS DETERMINED BY THE APPLICANT OF RECORD, AND NO LESS THAN 15% OF MINOR EQUIPMENT UNITS, SHALL BE VERIFIED BY VISUAL INSPECTION AND, WHERE NECESSARY, REVIEW OF MANUFACTURER'S DATA. POOL HEATERS AND COVERS SHALL BE VERIFIED BY VISUAL INSPECTION.

IIB4

HVAC SYSTEM CONTROLS AND ECONOMIZERS AND SERVICE HOT WATER SYSTEM CONTROLS

APPROVED CONSTRUCTION DOCUMENTS, INCLUDING CONTROL SYSTEM NARRATIVES; ASHRAE GUIDELINE 1: THE HVAC COMMISSIONING PROCESS

503.2.4, 503.2.5.1, 503.2.11, 503.3, 503.4, 504.3, 504.6, 504.7; ASHRAE 90.1 - 6.3, 6.4, 6.5, 6.7.2.4, 7.4.4, 7.4.5

NO LESS THAN 20% OF EACH TYPE OF REQUIRED CONTROLS AND ECONOMIZERS SHALL BE VERIFIED BY VISUAL INSPECTION AND TESTED FOR FUNCTIONALITY AND PROPER OPERATION. SUCH CONTROLS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THERMOSTATIC; SET POINT OVERLAP RESTRICTION; OFF-HOUR; SHUTOFF DAMPER; DEMAND CONTROL SYSTEMS; ZONES; ECONOMIZERS; AIR SYSTEMS; VARIABLE AIR VOLUME FAN; HYDRONIC SYSTEMS; HEAT REJECTION EQUIPMENT FAN SPEED; COMPLEX MECHANICAL SYSTEMS SERVING MULTIPLE ZONES; VENTILATION; ENERGY RECOVERY SYSTEMS; HOT GAS BYPASS LIMITATION; TEMPERATURE; SERVICE WATER HEATING; HOT WATER SYSTEM; POOL HEATER AND TIME SWITCHES; EXHAUST HOODS AND RADIANT HEATING SYSTEMS. CONTROLS WHOSE COMPLETE OPERATION CANNOT BE DEMONSTRATED DUE TO PREVAILING WEATHER CONDITIONS TYPICAL OF THE SEASON DURING WHICH PROGRESS INSPECTIONS WILL BE PERFORMED SHALL BE PERMITTED TO BE SIGNED OFF FOR THE PURPOSE OF A TEMPORARY CERTIFICATE OF OCCUPANCY WITH ONLY A VISUAL INSPECTION, PROVIDED, HOWEVER, THAT THE PROGRESS INSPECTOR SHALL PERFORM A SUPPLEMENTAL INSPECTION WHERE THE CONTROLS ARE VISUALLY INSPECTED AND TESTED FOR FUNCTIONALITY AND PROPER OPERATION DURING THE NEXT IMMEDIATE SEASON THEREAFTER.

IIB5

DUCT, PLENUM AND PIPING INSULATION AND SEALING

IIC

ELECTRICAL POWER AND LIGHTING SYSTEMS

IIC3

INTERIOR LIGHTING POWER

IIC5

LIGHTING CONTROLS

503.2.7, 503.2.8, 504.5; ASHRAE 90.1 - 6.3, 6.4.4.2, 6.8.2, 6.8.3; 7.4.3

INSTALLED DUCT AND PIPING INSULATION SHALL BE VISUALLY INSPECTED TO VERIFY PROPER INSULATION PLACEMENT AND VALUES. JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS AND CONNECTIONS IN DUCTWORK SHALL BE VISUALLY INSPECTED FOR PROPER SEALING.

APPROVED CONSTRUCTION DOCUMENTS

505.5; ASHRAE 90.1 - 9.1, 9.2, 9.5, 9.6; 1RCNY §101-07(C)(3)(V)(C)4

INSTALLED LIGHTING SHALL BE VERIFIED FOR COMPLIANCE WITH THE LIGHTING POWER ALLOWANCE BY VISUAL INSPECTION OF FIXTURES, LAMPS, BALLASTS AND TRANSFORMERS.

APPROVED CONSTRUCTION DOCUMENTS, INCLUDING CONTROL SYSTEM NARRATIVES

505.2; ASHRAE 90.1 - 9.4.1

EACH TYPE OF REQUIRED LIGHTING CONTROLS, INCLUDING MANUAL INTERIOR LIGHTING CONTROLS, LIGHT-REDUCTION CONTROLS, AUTOMATIC LIGHTING SHUT-OFF, DAYLIGHT ZONE CONTROLS AND EXTERIOR LIGHTING CONTROLS, SHALL BE VERIFIED BY VISUAL INSPECTION AND TESTED FOR FUNCTIONALITY AND PROPER OPERATION.

APPROVED CONSTRUCTION DOCUMENTS; SMACNA DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE

The Glass Farmhouse Condominium 448 West 37th Street, New York NY Coombs & Associates, Inc. , 2012

The Glass Farmhouse Condominum is a renovation project for internationally acclaimed sculptor Pablo Atchugarry. The project is a gut renovation for an existing penthouse apartment located in the Hell’s Kicthen meighborhood in New York City. The project includes a change in layout in order to convert the existing studio apartment into a small gallery space and loft apartment. It also includes new plumbing fixtures, flooring and ceiling. As well as mechanical & electrical work to fullfill the space’s needs. I was primarily responsible for the preliminary research as well as existing conditions survey & drafting. I was also responsible for the energy analysis as well as preliminary sketches and design ideas.

page | 1


page | 2


The Black Residence

138-60 Brookville Blvd, Rosedale NY Tergram Engineering Servoces, P.C. , 2007 138-60 Brookville Blvd was a project to convert an existing one family dwelling structure into a two family dwelling residence. The project included demolition of the existing property, as well as foundation & general construction work. I was primarily responsible for survey & drafting of existing & demolition work; and drafting of proposed work, as well as NYC DOB filing forms & procedures.

page | 3


page | 4


J

I

H

G

E

F

D

C

A

B

DIEGO AGUILERA ARCHITECTS, P.C.

K

5

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com NO.

REVISIONS DESCRIPTION

DATE

KEY PLAN

N

4

BLOCK:3052

LOT:9

STRUCTURAL ENGINEER:

3

MUNICIPAL CONSULTANT:

DESIGN CONSULTANT:

2 PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

DRAWING TITLE:

3D MODEL

SEAL AND SIGNATURE DATE: 8/11/2013 7:59:48 PM PROJECT NO.:31WALST

1

DRAWING BY:HV DRAWING No.:

3D Checker

SHEET

E DIEGO AGUILERA ARCHITECTS, P.C.

31'-0"

T.C: EL: + 13.47'

REVISIONS DESCRIPTION

SD CMD

page | 5

D10

A

A SD CMD

A

FOYER UP

D8

MECH. 6'-6"

EXIST. SHAFT 1'-0"

12'-7 1/2"

5'-0"

1

2

P-100.00 T-100.00 Z-100.00 Z-101.00 Z-102.00 Z-103.00 GraŶd total: 14

E

MV PROPOSED EXTERIOR WALL - TYPE 'C2'

GLASS BLOCK REVISION INDICATOR

?

STEEL

PROPOSED EXTERIOR WALL - TYPE 'C3' FLOOR ELEVATION SYMBOL

BATT INSULATION CAST-IN-PLACE CONCRETE

TO BE REMOVED HARD WIRED SMOKE & CARBONMONOXIDE DETECTOR TO COMPLY WITH NYC REGULATIONS

SD CMD ?

WINDOW SYMBOL

?

DOOR NUMBER

?

WALL / PARTITION TYPE

? ?

?

DETAIL REFERENCE SYMBOL

INSULATION RIGID

PLYWOOD

? ?

? ?

BOARD BUILDING BLOCKING BRACKET BRONZE

ROOM TAG ALUMINUM

CAB. CLKG.

W1

W1

E

CABINET CALKING CENTER LINE CLG. CEILING CLOS. CLOSET CLR. OPG. CLEAR OPENING COL. COLUMN CONC. CONCRETE CONN. CONNECT(ION) CONST. CONSTRUCTION CONT. CONTINUOUS CORR. CORRIDOR C.T. CERAMIC TILE CTR. CENTER C.W. COLD WATER

(E.) ELEC. EL. ENGR. EQ. EQUIP. EXH. E, EXIST. EXT. ELECT.

EAST ELECTRIC ELEVATION ENGINEER EQUAL EQUIPMENT EXHAUST EXISTING EXTERIOR ELECTRICAL

FR. FT. F.T. FURR. G

GAUGE GA. GENERAL GEN. GLASS OR GLAZED GL. GYP. BD. GYPSUM BOARD H HDWR. HDWD. HGT. H.M. HORIZ. H.W.

HARDWARE HARDWOOD HEIGHT HOLLOW METAL HORIZONTAL HOT WATER

I.D. INCL. INFO. INCAN.

LAM. LB. (OR #) L.H.

JANITOR

ANGLE LAMINATE POUND LEFT HAND

M MAINT. MAX. MECH. MTL. MEZZ. MFR. M.O. MIN. MTD. MUL. M.R. N

MAINTENANCE MAXIMUM MECHANICAL METAL MEZZANINE MANUFACTURER MASONRY OPENING MINIMUM MOUNTED MULLION MOISTURE RESISTANT

(N) N. N.I.C. NO.(OR #) N.T.S.

NORTH NEW NOT IN CONTRACT NUMBER NOT TO SCALE

O.A. O.C. O.D. O.H. OPNG. OPP. ORIG. P

OVERALL ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING OPPOSITE ORIGINAL

P.LAM. PLAS. PLY. PNL. PR. PREFAB. PTN. PTD. Q

PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAIR PREFABRICATED PARTITION PAINTED

QUAN. R

QUANTITY

REL. R. R/A RAD. RECEP. REF. REFL. REINF. REQD. R.H. RM. RND. R.O. REV.

RELOCATE REMOVE RETURN AIR RADIUS RECEPTACLE REFERENCE REFLECTED REINFORCED REQUIRED RIGHT HAND ROOM ROUND ROUGH OPENING REVISION

(S) S.C. SCHED. SECT. SHT. SIM. SQ. SF S.S. STD. STRUCT. SUSP. SYMM. SYS.

SOUTH SOLID CORE SCHEDULE SECTION SHEET SIMILAR SQUARE SQUARE FEET STAINLESS STEEL STANDARD STRUCTURAL SUSPEND(ED) SYMMETRICAL SYSTEM

T T&B TECH. TEL. TEMPD. TEMP. GL. THK. TYP. T.B.D. T.B.S.

WALL SECTION/DETAIL

D

VERTICAL VESTIBULE VERIFY IN FIELD VOLUME

FINISH WOOD

SPOT ELEVATION SYMBOL

GYPSUM BOARD

C

B

A-200.00 2

A-203.00

PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

10'-5"

13'-9 3/8"

4"

WEST WITH WALL COVERING WOOD WATER HEATER WITHOUT WEIGHT

REQ. LIGHT= 8.4 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 4.2 SF PROVIDE AIR= 16.6 SF 8'-5"

EXIST. BEDROOM #2 123 SF 4"

UNDERWRITERS LABORATORY UTILITY UNLESS OTHERWISE NOTED

YD.

A

MUNICIPAL CONSULTANT:

D5

DINING 157 SF REQ. LIGHT= 15.7 SF PROVIDED LIGHT= 40 SF REQ. AIR= 7.85 SF PROVIDE AIR= 40 SF

D10 2'-8"

11'-11" REQ. LIGHT= 12.3 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 6.15 SF PROVIDE AIR= 16.6 SF

8'-6"

4"

14'-2"

DESIGN CONSULTANT: 1'-0"

UP

D9

D4

CL

4"

SD CMD

EXIST. HALLWAY REQ. LIGHT= 8.5 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 4.25 SF PROVIDE AIR= 16.6 SF

W1

W1

W

D4

SD CMD

A D4

D6

D6

EXIST. CL

D7

EXIST. CLD7

D7

EXIST. CL

D2

D7

D1

BAR 85 SF

EXIST. STAIR

EXIST. BATH

DRAWING TITLE:

EXIST. CL

D1 UP

MV

TITLESHEET DN

SD CMD

EXIST. ELEVATOR

EXIST. SHAFT

MV

STORAGE 79 SF

EXIST. BATH

D6

EXIST. BEDROOM #4 128 SF REQ. LIGHT= 12.8 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 6.4 SF PROVIDE AIR= 16.6 SF

W1

1

1 A-200.00 2 Z-100.00

A-203.00

PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

W1

DRAWING TITLE:

4TH AND 5TH FLOOR PLANS

D6

YARD

MISCELLANEOUS ROUND SQ.FT.

1'-0"

7'-3 3/8"

4"

5'-1"

6"

12'-1"

5'-7"

4"

5'-0"

4"

9'-7"

2'-8"

11'-8"

SQUARE

SEAL AND SIGNATURE DATE: 8/11/2013 7:06:23 PM PROJECT NO.:31WALST DRAWING BY:HV DRAWING No.:

1

SEAL AND SIGNATURE DATE: 8/11/2013 7:05:37 PM PROJECT NO.:31WALST

62.45'

DRAWING BY:HV DRAWING No.:

T-100.00 SHEET

COLUMN LINE / GRID INDICATOR

?

?

VERT. VEST. V.I.F. VOL.

(W) W/ W.C. WD W.H. W/O WT.

EXIST. BALCONY

W1

D10

EXIST. CL

REQ. LIGHT= 14.5 SF PROVIDED LIGHT= 40 SF REQ. AIR= 7.25 SF PROVIDE AIR= 40 SF

D5

Y TOP AND BOTTOM TECHNICAL TELEPHONE TEMPERED TEMPERED GLASS THICK(NESS) TYPICAL TO BE DETERMINED TO BE SELECTED

U U.L. UTIL. U.O.N.

1

V

S

O INSIDE DIAMETER INCLUDE(D)(ING) INFORMATION INCANDESCENT

J JAN. L

W1

PROPERTY LINE

4"

I FIRE ALARM FABRICATE FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FINISH(ED) FLOOR FLUORESCENT FACE OF WALL FIRE PROOF SELF-CLOSING FRAME FOOT OR FEET FIRE-TREATED FURRING

6'-6 3/8"

W1

EXIST. BEDROOM #1 84 SF

11'-1"

DEN 145 SF

5'-11"

24.35'

F F.ALM. FABR. F.E. F.E.C. F.F. FIN. FLR. FLUOR. F.O.W. FPSC

LOT:9

1'-0"

5 7/8" 9'-11"

EXIST. BALCONY

DESIGN CONSULTANT:

SCALE: 1/64" = 1'-0"

W1

PROPERTY LINE

W/D

B.C: EL: + 13.19'

62'-5 3/8"

MUNICIPAL CONSULTANT:

2 DOUBLE DEPARTMENT DETAIL DIAMETER DIMENSION DIVISION DOWN DOOR DRAWING DRAWER

1'-0"

1

EXISTING TREE

W/D

BD. BLDG. BLKG. BRKT. BRZ. C

? ?

DBL. DEPT. DET. DIA. DIM. DIV. DN. DR. DWG. DRW.

14'-2"

A-201.00 Z-100.00

SCALE: 1/4" = 1'-0"

3'-8"

MECH. VENT

DRAWING LIST SHEET NAME EXISTING 1ST, 2ND & 3RD FLOOR PLANS 4TH AND 5TH FLOOR PLANS 6TH FLOOR & ROOF PLAN WALTON STREET & FRONT ELEVATIONS MARCY AVENUE ELEVATION LONGITUDINAL & CROSS SECTIONS GENERAL NOTES GENERAL NOTES - CONT, DOOR & WINDOW SCHEDULE, & ENERGY ANALYSIS PLUMBING RISER DIAGRAM & NOTES TITLESHEET LOT DIAGRAM & SITE PLAN WEST LOT DIAGRAM EAST LOT DIAGRAM & LOT COVERAGE CALCULATIONS TAX MAP, ZONING MAP & ARCHITECTURAL SURVEY

AIR CONDITIONING ACOUSTICAL ADJUSTABLE ALUMINUM ALTERNATE ANODIZED APPROVED APPROXIMATE ARCHITECT(URAL) AVERAGE ABOVE FINISH FLOOR

4"

STRUCTURAL ENGINEER:

5TH FLOOR PLAN

2'-6 1/4"

A-100.00 A-101.00 A-102.00 A-200.00 A-201.00 A-203.00 G-100.00 G-101.00

A/C ACOUS. ADJ. ALUM. ALT. ANOD. APPD. APPROX. ARCH. AVG. A.F.F. B

5'-10"

BLOCK:3052

STRUCTURAL ENGINEER:

EXIST. DOOR TO REMAIN

SHEET NUMBER

CONCRETE MASONRY UNITS

9'-4 1/2"

LOT:9

REF.

BRICK

N

W1

1'-0"

BLOCK:3052

SITE MAP - BLOCK 2244, LOT 7501

KEY PLAN

62.33'

11'-7 1/4"

EARTH (exiƐƟŶŐͿ BACKFILL ;Ŷew) NORTH ARROW

REQ. LIGHT= 8.2 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 4.1 SF PROVIDE AIR= 16.6 SF

A

MV

BATH

DATE

C3

12'-6"

D4

D

A EXISTING WALLS PROPOSED 1 HR WALL TYPE 'A'

D6

CL

STAIRS

ABBREVIATIONS

PROPOSED 2 HOUR WALL TYPE 'B'

A

B

B

REVISIONS DESCRIPTION

W1

LIVING 82 SF

A

A

C3

13'-11 1/4"

31 WALTON STREET, BROOKLYN, NY 11206 2244 7501 R7-1 13 B

D1

B

6'-4"

D2

MARCY AVENUE T.C: EL: + 13.77'

LEGEND

NO.

C1

B

MV

1'-0"

31 WALTON STREET BLOCK 2244 LOT 7501

2

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

DINING 185 SF A SD CMD

DESIGN & ARCHITECTURE

PROPERTY LINE

D4

SD CMD

SITE INFORMATION

W1

4'-6"

NEW SKYLIGHT MIN 20 S.F.

REQ. LIGHT= 10.2 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 5.1 SF PROVIDE AIR= 16.6 SF

18'-1"

EXISTING 4 STORY BRICK RESIDENTIAL BUILDING

1'-0"

W1

REQ. LIGHT= 18.7 SF PROVIDED LIGHT= 33.2 SF REQ. AIR= 9.35 SF PROVIDE AIR= 33.2 SF

DN

7'-0"

KITCHEN 102 SF

W1

W1

3 6'-6 3/8"

W1

22'-2"

24.5' SCALE: 1" = 200'-0"

(70' WIDE)

WALTON STREET

4

SITE MAP - BLOCK 2244

11'-1"

T.C: EL: + 13.61'

B.C: EL: + 13.26'

38'-0 1/8"

CONCRETE SIDEWALK EL: + 14.06'

16'-9"

EXISTING 4 STORY BRICK W/ NEW 2 STORY ADDITION RESIDENTIAL BUILDING

A

B

SCALE: 3/16" = 1'-0"

ADDRESS BLOCK LOT ZONING DISTRICT ZONING MAP

LAUNDRY / P.KIT 96 SF

REQ. LIGHT= 9.6 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 4.8 SF PROVIDE AIR= 16.6 SF

B

A

N

DIRT/EARTH

6TH FLOOR TERRACE

31 WALTON STREET BROOKLYN, NY 11206 BLOCK: 2244 LOT: 7501

14'-2"

W1

C2

MV

A

REQ. LIGHT= 8 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 4 SF PROVIDE AIR= 16.6 SF

D4

KEY PLAN

1

SITE PLAN

2

4"

W1

D10

PLAY ROOM 80 SF

REQ. LIGHT= 16.3 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 8.15 SF PROVIDE AIR= 16.6 SF

W1

10'-1"

EL: +13.98' 26'-10"

8'-9"

36'-0"

PROPOSED EXTERIOR WALL - TYPE 'C1'

I was responsible for existing condictions surveying & drafting, proposed work drafting, and zoning calculations. Moreover, I was also in charge of presentation drawings & layouts.

8'-0"

MAX. 22"

DIRT/EARTH

MAX. 22"

3RD FL BALCONY 4TH FL BALCONY

EL: +15.20'

6

W1

A

17'-9"

EL: +14.75'

5TH FLOOR BALCONY

2ND FL BALCONY

31 Walton Street in an extension project to add 2 storeys to an existing 4 story muti-dwelling building. The work proposed work involves zoning research and analysis and general construction.

10'-10"

W1

A

4TH FLOOR BALCONY

3

9'-6"

W1

C1

4

Samuel Wieder + Associates & Diego Aguilera Architects, P.C. , 2013

4" 1'-10" 6"

W1

C2

DINETTE 163 SF

W1

DATE

CONCRETE SIDEWALK

31 Walton Street, Brooklyn NY

9'-8"

W1

D5

11'-1"

NO.

31'-4"

4"

10'-6"

BALCONY

WALTON STREET

EXISTING TREE

12'-6"

2'-0"

PROPERTY LINE

PROPERTY LINE

WALTON STREET

1'-0"

5

24'-4 1/4"

EXISTING TREE

DIRT/EARTH

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

B.C: EL: + 13.03'

T.C: EL: + 13.93'

1

10'-11 1/4"

(70' WIDE)

EXISTING TREE

B.C: EL: + 13.32'

A

B

A-201.00 Z-100.00

PROPERTY LINE

BLOCK 2244

MARCY AVENUE

EXISTING TREE

C

2 A-203.00

MARCY AVENUE

1'-4"

5TH & 6TH FL ADDITION TO EXISTING 4 STORY BUILDING 5

D

DIEGO AGUILERA ARCHITECTS, P.C.

A

B

EXIST. CL

C

31 WALTON STREET, BROOKLYN NY 11206

A

B

10'-8"

D

C

W

E

D

D

E

F

TOY CL

G

10'-4"

H

4'-6"

I

1'-10"

J

1'-4"

K

A-101.00

2

Checker

1

A-203.00

4TH FLOOR PLAN

SHEET

SCALE: 1/4" = 1'-0"

E

D

C

B

A

Checker


1

1 A-200.00 2 Z-100.00

KEY PLAN

A-203.00

N

4

NEW FACE BRICK

W1

W1

W1

W1

W1 NEW FACE BRICK

6TH FLOOR 69.84' NEW FACE BRICK

W1

W1

W1

W1

NEW FACE BRICK

W1

W1

C

3'-10 7/8"

5

ROOF PLAN 80.17'

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com REVISIONS DESCRIPTION

NO.

W1

W1

DATE

W1

D10

D10

FACE BRICK 1/2" AIR GAP ON 4" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BD.

W1

D2

FACE BRICK 1/2" AIR GAP ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BD.

KEY PLAN W1

D5

4

D4

W1

W1

W1

W1

W1

N

D4

10'-4"

10'-4"

D10

4"

15'-0"

MUNICIPAL CONSULTANT:

W1

W1

PROPERTY LINE

C2 / 12"

BEDROOM #3 104 SF

1/4" 1/4" 1/4"

FD

/ 12"

/ 12"

W1

2

DESIGN CONSULTANT:

/ 12"

DECK W1

C1

D2 A

CL

A

A D4

C1

A

A

A

6"

3'-2"

B

3'-0"

D3

D3

BEDROOM #4 133 SF

A

A

6'-8"

WIC MV

A D1

STORAGE

B

SD CMD

STAIRS DN

7'-4"

4"

5'-0"

SD CMD

B

C3

1'-0"

6"

11'-11"

D4

B 8'-6"

3'-0" 8'-0"

D8 B B

12'-9"

B D2 A

EXIST. SHAFT

2

REQ. LIGHT= 13.3 SF PROVIDED LIGHT= 32.2 SF REQ. AIR= 6.65 SF PROVIDE AIR= 32.2 SF

W1

PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

11'-6"

DRAWING TITLE:

A

BATH

6TH FLOOR & ROOF PLAN

A MV

8'-0"

4"

1

C

1

J

Checker

A

B

I

E

H

G

SEAL AND SIGNATURE DATE: 8/11/2013 7:05:50 PM PROJECT NO.:31WALST DRAWING BY:HV DRAWING No.:

A-102.00

WALTON STREET ELEVATION

2

SCALE: 1/4" = 1'-0"

D

10'-0"

DRAWING TITLE:

LONGITUDINAL & CROSS SECTIONS

GRADE 14.50'

CELLAR 9.83'

1

SEAL AND SIGNATURE DATE: 8/11/2013 7:06:06 PM PROJECT NO.:31WALST DRAWING BY:HV DRAWING No.:

A-200.00

FRONT ELEVATION

SHEET

SCALE: 1/4" = 1'-0"

C

F

PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

B

E

A-203.00

Checker

1

A

LONGITUDINAL SECTION

C

1 A-203.00

SCALE: 1/4" = 1'-0"

2 E

D

2 A-203.00

D

C

B

SHEET

Checker

CROSS SECTION SCALE: 1/4" = 1'-0"

A

B

A DIEGO AGUILERA ARCHITECTS, P.C.

K

D

A-203.00

A-203.00

A-203.00

SHEET

E

WALTON STREET & FRONT ELEVATIONS

1

1

SEAL AND SIGNATURE DATE: 8/11/2013 7:05:39 PM PROJECT NO.:31WALST

2

SCALE: 1/4" = 1'-0"

DRAWING TITLE:

GRADE 14.50'

DRAWING BY:HV DRAWING No.:

6TH FLOOR PLAN

EXISTING NO CHANGE

EXISTING 2ND FLOOR 29.17'

EXISTING 1ST FLOOR 19.17'

BASE PLANE CALCULATION: (15.20' + 14.75 + 14.06 + 13.98) = 58.00'/4 = 14.50'

9'-8" 15'-0"

1

DESIGN CONSULTANT:

EXISTING NO CHANGE 2 PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

C3

5'-5"

DESIGN CONSULTANT:

EXISTING 1ST FLOOR 19.17'

W1

62'-4"

1

EXISTING 2ND FLOOR 29.17'

MUNICIPAL CONSULTANT:

B

CL

WH

2'-6" SD CMD

D4 D4

M. BATH

PROPERTY LINE

LIN. D7

A D1

W1

14'-9"

CL

D4

MECH

B

D10

2'-0"

24'-6"

A-200.00 2

D10 3'-9"

D10 C1

EXISTING 3RD FLOOR 39.17'

MUNICIPAL CONSULTANT:

10'-0"

C1

A

EXISTING 3RD FLOOR 39.17'

4'-8"

A REQ. LIGHT= 10.4 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 5.2 SF PROVIDE AIR= 16.6 SF A

STREET

REQ. LIGHT= 10.4 SF PROVIDED LIGHT= 16.6 SF REQ. AIR= 5.2 SF PROVIDE AIR= 16.6 SF

WALTON

14'-2"

BEDROOM #2 104 SF

A

REQ. LIGHT= 17.2 SF PROVIDED LIGHT= 32.2 SF REQ. AIR= 8.6 SF PROVIDE AIR= 32.2 SF

9'-4"

MASTER BEDROOM #1 172 SF

W1

9'-9"

1/4"

9'-9"

C2

W1

6'-6 3/8"

10'-5"

W1

LOT:9

10'-0"

W1

BLOCK:3052 STRUCTURAL ENGINEER:

3

4'-8"

PROPERTY LINE

D4

10'-0"

11'-10"

10'-5"

4'-0"

D9

4'-8"

W1

D10

EXISTING 4TH FLOOR 49.17'

LOT:9

STRUCTURAL ENGINEER:

RSIDENTIAL BUILDING - NO CHANGE

2'-0"

W1

EXISTING 4 STORY ADJACENT BUILDING

4"

2'-0"

EXISTING 4 STORY

62'-4" 35'-6" 12'-0" 4'-0"

EXISTING 4 STORY

1

10'-0"

3

A-201.00 Z-100.00

BLOCK:3052

1'-10"

10'-0"

MARCY AVENUE

DATE

KEY PLAN

N

EXISTING 4TH FLOOR 49.17' 1'-10"

EXISTING 4 STORY ADJACENT BUILDING

SCALE: 1/4" = 1'-0"

3

REVISIONS DESCRIPTION

NO.

D4

1'-10"

LOT:9

RESIDENTIAL BUILDING - NO CHANGE

BLOCK:3052 STRUCTURAL ENGINEER:

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

TYP. FLOOR ASSEMBLY 3/4" HARWOOD FLOORING ON 3/4" PLYWOOD SUBSTRATE MTL. JOIST 3/4" PLYWOOD SUBSTRATE & 1 LAYER 5/8" TYP. X GYP. BD

5TH FLOOR PLAN 59.51'

1'-10"

ROOF PLAN

DESIGN & ARCHITECTURE

6TH FLOOR 69.84'

63.33'

2

DIEGO AGUILERA ARCHITECTS, P.C.

1 A-203.00

5TH FLOOR PLAN 59.51'

7'-10 1/2"

A

B

2 A-203.00

10'-4"

ROOF PLAN 80.17'

DATE

D

10'-4"

REVISIONS DESCRIPTION

3"

3"

3"

3"

12"

12"

12"

12"

3"

E

DESIGN & ARCHITECTURE

3'-7 1/2"

3" / 12"

4'-0"

12'-9"

5'-0"

1

3" / 12"

14'-11"

A

B

A-203.00

PROPOSED 2 STORY

A-203.00

4

WALTON STREET

8'-10 1/2"

3" / 12"

1

26'-6"

A-200.00 2

NO.

3" / 12"

12'-9"

DECK

12"

5

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

6'-6 3/8" 8'-9"

26'-10"

C

RESIDENTIAL EXTENSION

1'-0"

36'-0"

D

1 A-203.00

10'-4"

MARCY AVENUE

5

E

DESIGN & ARCHITECTURE

10'-4"

1

DIEGO AGUILERA ARCHITECTS, P.C.

A

B

A-201.00 Z-100.00

2 A-203.00

PROPOSED 2 STORY

C

RESIDENTIAL EXTENSION

D

DIEGO AGUILERA ARCHITECTS, P.C.

E

5

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com NO.

REVISIONS DESCRIPTION

DATE

KEY PLAN

N

4

BLOCK:3052

LOT:9

STRUCTURAL ENGINEER:

3

MUNICIPAL CONSULTANT:

DESIGN CONSULTANT:

2 PROJECT: 5TH & 6TH FL ADDITION TO EXIST. 4 ST. BLDG.

DRAWING TITLE:

3D SECTIONS

SEAL AND SIGNATURE DATE: 8/11/2013 8:12:40 PM PROJECT NO.:31WALST

1

DRAWING BY: Author DRAWING No.:

3D - S SHEET

K

J

I

H

G

F

E

D

C

B

Checker

A

page | 6


A

B

SECTION

USES PERMITTED AS-OF-RIGHT MAX. FLOOR AREA RATIO MAX. FLOOR AREA MAX. LOT COVERAGE DWELLING UNIT FACTOR MAX. # DWELLING UNITS ZR 23-462 MIN. SIDE YARD ZR 23-541 MIN. REAR YARD ZR 23-633 FRONT YARD / STREET WALL LOCATION REQUIRED SETBACK BASE HEIGHT MAX. BUILDING HEIGHT ZR 25-241, ZR-25-261 MIN. PARKING SPACES ZR 26-41 STREET TREE PLANTING

4

NO.

ZONING ANALYSIS MAX. ALLOWED OR MIN. REQ'D

DESCRIPTION

ZR 22-00 ZR 23-952

ZR 23-145 ZR 23-22

REVISIONS DESCRIPTION

ZR 25-811

BICYCLE PARKING

SECTION

DATE

ZR 28-33 ZR 28-41

NO.

REVISIONS DESCRIPTION

DATE

KEYPLAN

N/A 40' 40' ( 8 X .5 = 4 ) LESS THAN 5 WAIVED (PER ZR 25-261) STREET FRONTAGE:28'-10" / 25'-0" = 2 TREES WAIVED, ZR25-811 (a) BUILDINGS OR BUILDING SEGMENTS CONTAINING 10 DWELLING UNITS OR LESS

N

BASE PLANE CALCULATION: 41.92' + 41.86' / 2 = 41.89'

PROPOSED

400 S.F. MIN. PER DWELLING UNIT DOUBLE GLAZED ENCLOSED REFUSE AREA TO BE PROVIDED AT A RATE OF 2.9 C.F. PER D.U., A MIN. OF 12 S.F.(MIN. DIM. 3 FT.) . LAUNDRY FACILITIES 1 PER 20 DWELLING UNITS DAYLIGHT IN CORRIDORS 50% OF CORRIDOR CAN BE EXCLUDED IF DAYLIGHT IN CORRIDOR IS PROVIDED & MEETS REQ. RECREATION SPACE REQ. FOR 9 D.U. & 3.3% OF FLOOR AREA OVER PLANTING AREAS AREA BETWEEN THE STREET LINE AND THE STREET WALL SHALL BE PLANTED. DENSITY PER CORRIDOR 50% OF CORRIDOR AREA CAN BE EXCLUDED FROM F.A. IF LESS THAN 11 D.U.'S ARE SERVED BY THE CORRIDOR PER STORY.

ZR 28-31

3

STAIR BULKHEAD

ROOF 81.89'

8 DWELLING UNITS N/A 41'-11" 6'-0" ALIGNED

MIN. DWELLING UNIT SIZE WINDOWS REFUSE STORAGE & DISPOSAL

ZR 28-24 ZR 28-25

PL

USE GROUP:2 2 .0 5,766 SF 1,649 SF

QUALITY HOUSING REGULATIONS MAX. ALLOWED OR MIN. REQ'D

DESCRIPTION

ZR 28-21 ZR 28-22 ZR 28-23

PROPOSED

USE GROUPS: (RESIDENTIAL)1-4 2.0 5,766 SF = (2,883 X 2.00) 60% (2,883 X .60 = 1,729.SF) 680 8 DWELLING UNITS (5,766 / 680) N/ A 30' MINIMUM N/A / STREET WALL TO ALIGN WITH ADJACENT BUILDING 15'-0" NARROW STREET 40' 50' 50% OF DWELLING UNITS ONE STREET TREE SHALL BE PROVIDED FOR EVERY 25 FEET OF STREET FRONTAGE OF THE ZONING LOT. 1 PER 2 DWELLING UNITS

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

ABOVE MAX BASE HEIGHT

BLUKHEAD 10'-0"

DESIGN & ARCHITECTURE

ON NARROW STREET SETBACK 15'-0"

ROOF ACCESS

BLOCK LOT ZONING DISTRICT ZONING MAP LOT AREA USE GROUP CONSTRUCTION CLASS OCCUPANCY GROUP

5

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

NEW 4 STORY RESIDENTIAL BUILDING

221 SPENCER STREET, BROOKLYN, NY 11205 1763 3 R6B 17A 2,883 SF 2 IIA R-2

40'-0"

DIEGO AGUILERA ARCHITECTS, P.C.

SPENCER STREET BROOKLYN NY 11205

5

C

SITE INFORMATION ADDRESS

221

D

DIEGO AGUILERA ARCHITECTS, P.C.

E

A

B

BUILDING HEIGHT

C

40'-0"

D

MAX. BASE HEIGHT PER ZR 23-633

E

SMALLEST DWELL UNIT = 587 SF, COMPLIES COMPLIES N/A, TOTAL # OF DWELLING UNITS IS LESS THAN 9

SPENCER STREET

1ST FLOOR 41.89' 6'-0"

N/A, DEVELOPMENT IS LESS THAN 20 UNITS COMPLIES

52'-1" BUILDING

FRONT YARD

2

N/A, TOTAL # OF DWELLING UNITS IS LESS THAN 9

HEIGHT & SETBACK DIAGRAM

STRUCTURALENGINEER:

SCALE: 1/8" = 1'-0"

COMPLIES COMPLIES, CORRIDOR SERVES 2 DWELLING UNITS PER FLOOR.

MUNICIPALCONSULTANT:

DEKALB AVENUE

14'-10"

D

E

D

GLASS BLOCK

? ? ?

FLOOR ELEVATION SYMBOL

? ?

? ?

?

WALL SECTION/DETAIL

BATT INSULATION CAST-IN-PLACE CONCRETE

WALL / PARTITION TYPE

1

STEEL

?

DETAIL REFERENCE SYMBOL

PLYWOOD

? ?

INSULATION RIGID

ROOM TAG

ALUMINUM FINISH WOOD

?

COLUMN LINE / GRID INDICATOR

SPOT ELEVATION SYMBOL

C CAB. CLKG. CLG. CLOS. CLR. OPG. COL. CONC. CONN. CONST. CONT. CORR. C.T. CTR. C.W.

CABINET CALKING CENTER LINE CEILING CLOSET CLEAR OPENING COLUMN CONCRETE CONNECT(ION) CONSTRUCTION CONTINUOUS CORRIDOR CERAMIC TILE CENTER COLD WATER

(E.) ELEC. EL. ENGR. EQ. EQUIP. EXH. E, EXIST. EXT. ELECT.

A

2'-0"

GA. GEN. GL. GYP. BD.

GAUGE GENERAL GLASS OR GLAZED GYPSUM BOARD

H HDWR. HDWD. HGT. H.M. HORIZ. H.W.

HARDWARE HARDWOOD HEIGHT HOLLOW METAL HORIZONTAL HOT WATER

ANGLE LAMINATE POUND LEFT HAND

MAINT. MAX. MECH. MTL. MEZZ. MFR. M.O. MIN. MTD. MUL. M.R. N

MAINTENANCE MAXIMUM MECHANICAL METAL MEZZANINE MANUFACTURER MASONRY OPENING MINIMUM MOUNTED MULLION MOISTURE RESISTANT

(N) N. N.I.C. NO.(OR #) N.T.S.

NORTH NEW NOT IN CONTRACT NUMBER NOT TO SCALE

PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAIR PREFABRICATED PARTITION PAINTED

QUAN. R

QUANTITY

REL. R. R/A RAD. RECEP. REF. REFL. REINF. REQD. R.H. RM. RND. R.O. REV.

RELOCATE REMOVE RETURN AIR RADIUS RECEPTACLE REFERENCE REFLECTED REINFORCED REQUIRED RIGHT HAND ROOM ROUND ROUGH OPENING REVISION

T T&B TECH. TEL. TEMPD. TEMP. GL. THK. TYP. T.B.D. T.B.S.

U.L.

9"

2

UNDERWRITERS LABORATORY UTILITY UNLESS OTHERWISE NOTED

YD.

8'-3"

KEYPLAN

N

SCALE: 3/16" = 1'-0"

52'-1"

3'-0"

2

28'-10"

4'-7 1/2"

4 SF

6 1/2"

1

STREET

4'-7 1/2" 5'-11" MECH. DEDUCTION

AREA

6 SF

DN

MUNICIPALCONSULTANT:

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

SPENCER

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DN

MECH. 1ST FLOOR NET FLOOR DEDUCTION 1,338 SF

6"

4 SF

18'-7"

5'-4 1/2" DN

MECH. DEDUCTION

DESIGNCONSULTANT:

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

5'-11"

7'-0"

4'-0 1/2"

9'-7 1/4"

5'

-0

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

STRUCTURALENGINEER:

1'-8"

16'-7 1/4"

150 SF

5'-0"

3'-1"

4"

1'-4" 5'-11"

8"

DAYLIGHT & DENSITY DEDUCTION

10"

31'-5"

UP 5'-10 1/4"

5'-5"

3'-10"

4'-0"

16'-10"

1'-11"

WEST WITH WALL COVERING WOOD WATER HEATER WITHOUT WEIGHT

1ST FLOOR AREA PLAN

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

SCALE: 3/16" = 1'-0"

DRAWING TITLE: TITLESHEET

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DRAWING TITLE: AREA PLANS

YARD

MISCELLANEOUS ROUND SQ.FT. SQUARE

SEALANDSIGNATURE

DATE: 8/11/2013 8:38:59 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

FLOOR

1

FLOOR AREA CALCULATIONS DEDUCTIONS DENSITY

GROSS FLOOR AREA

DAYLIGHT

MECHANICAL

TOTAL N.F.A.

1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR

1,502 SF 1,502 SF 1,502 SF 1,502 SF

75 SF

75 SF 12 S F 12 SF 12 S F

14 SF 14 SF 14 S F 14 SF

1,338 SF 1,476 SF 1,476 SF 1,476 SF

TOTALS

6,008 SF

75 SF

111 SF

56 S F

TOTAL ZFA: 5,766 SF OK

SEALANDSIGNATURE

DATE: 8/11/2013 8:39:12 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

Z-101.00 SHEET 3 OF 18

T-100.00

E

D

C

A

B

SHEET 1 OF 18

GYPSUM BOARD E

D

C

BC CHAPTER 3 USE & OCCUPANCY CLASSIFICATION

221 Spencer Street, Brooklyn NY

REQUIREMENT

ITEM

GROUP:

USE:

R-2

RESIDENTIAL

BC CHAPTER 12 INTERIOR ENVIRONMENT

BC CHAPTER 5 GENERAL HEIGHTS & LIMITATIONS

MDL NOTES

Samuel Wieder + Associates & Diego Aguilera Architects, P.C. , 2013 BC 504.2 HEIGHT MODIFICATIONS WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1, THE VALUE SPECIFIED IN TABLE 503 FOR MAXIMUM HEIGHT IS INCREASED BY 20 FEET AND THE MAXIMUM NUMBER OF STORIES IS INCREASED BY ONE STORY

221 Spencer Street is a proposal for a new 4 story muti-dwelling building. It is a development that takes advantage of floor area incentives via quaility housing regulations & compliance.

BC CHAPTER 6 TYPES OF CONSTRUCTION

TABLE 601 FIRE - RESISTANCE RATING REQUIREMENT FOR BUILDING ELEMENTS TYPE II BUILDING ELEMENTS A STRUCTURAL FRAME - INCLUDING COLUMNS,GIRDER & TRUSSES BEARING WALLS -EXTERIOR BEARING WALLS -INTERIOR NON-BEARING WALLS AND PARTITIONS - EXTERIOR NON-BEARING WALLS AND PARTITIONS - INTERIOR FLOOR CONSTRUCTION - INCLUDING SUPPORTING BEAMS AND JOISTS ROOF CONSTRUCTION - INCLUDING SUPPORTING BEAMS AND JOISTS

3

<5 > 5 TO < 10 > 10 TO < 30

> 30

My responsibilities for this project included zoning analysis, research & calculations. Building code research and drafting of proposed work, in addition to bulk & desnity diagrams, and street tree & planting regulations compliance.

0 1 1

ALL IA OTHER IA, IB IIB, VB OTHER ALL

1 1 1 1 0 1 0

BC CHAPTER 10 MEAN OF EGRESS

BC1014.2.1 MIN. DISTANCE BETWEEN TWO EXITS R-2 OCCUPANCIES. IN GROUP‡ R-2 OCCUPANCIES, WHERE STAIRS ARE ENCLOSED IN WALLS HAVING AT LEAST A 2-HOUR FIRE-RESISTANCE RATING AND CONSTRUCTED OF MASONRY OR MASONRY EQUIVALENT IN ACCORDANCE WITH DEPARTMENT RULES: 3.1. THE EXIT DOORS TO SUCH STAIRS SHALL BE PLACED A DISTANCE APART EQUAL TO NO LESS THAN 15 FEET

BC CHAPTER 10 MEAN OF EGRESS

BC 1023 EXIT DISCHARGE IN BUILDINGS IN OCCUPANCY GROUP R-2, UP TO 100 PERCENT OF THE NUMBER AND CAPACITY OF THE EXIT ENCLOSURES IS PERMITTED TO EGRESS THROUGH A PROTECTED AREA ON THE LEVEL OF DISCHARGE.

2

BC CHAPTER 11 ACCESIBILITY

WIND LOADS AND EARTHQUAKE LOADS

BC1207.2 ROOM CONTAINING HVAC UNITS ON EACH FLOOR HAS TO COMPLY WITH BC 1207.2. MINIMUM SOUND TRANSMISSION CLASS (STC) FOR AIR-BORN NOISE OF NOT LESS THAN 50. TYP.

4. CONTRACTORS: (BC 3301.2) CONTRACTORS, CONSTRUCTION MANAGERS, & SUBCONTRACTORS ENGAGED IN BUILDING WORK SHALL INSTITUTE AND MAINTAIN SAFETY MEASURES & PROVIDE ALL EQUIPMENT OR TEMPORARY CONSTRUCTION NECESSARY TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY SUCH CONTRACTOR'S OPERATIONS.

Comments

ADJOINING CHIMNEYS AND VENTS SHALL BE IN ACCORDANCE WITH SECTIONS 2113.1.6.1 TO 2113.1.6.8. BC 2113.1.6.1 RESPONSIBILITY OF OWNER OF TALLER BUILDING. WHENEVER A BUILDING IS ERECTED, ENLARGED, OR INCREASED IN HEIGHT SO THAT ANY PORTION OF SUCH BUILDING, EXCEPT CHIMNEYS OR VENTS, EXTENDS HIGHER THAN THE TOP OF ANY PREVIOUSLY CONSTRUCTED CHIMNEYS OR VENTS WITHIN 100 FEET (30 480 MM), THE OWNER OF SUCH NEW OR ALTERED BUILDING SHALL HAVE THE RESPONSIBILITY OF ALTERING SUCH CHIMNEYS OR VENTS TO MAKE THEM CONFORM WITH THE REQUIREMENTS OF THIS CHAPTER.

by wriƟŶg. . NOTIFICATION TO ADJACENT BUILDINGS OWNERS ARE REQUIRED NOT LESS THAN 10 DAYS IN ADVANCE OF CERTAIN EARTHWORK OPERATIONS: - EXCAVATIONS BETWEEN 5 FEET & 10 FEET DEEP, & WITHIN 10 FEET OF AN ADJACENT BUILDINGS . NOTIFICATION MUST PROVIDE: - DESCRIPTION OF WORK. - TIMEFRAME & SCHEDULE. - CONTACT INFORMATION OF PERSON CAUSING EXCAVATION & DOB. EACH SUBCONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION OF EXCAVATION SITES. PROTECTION OF EXCAVATION SITES (BC 3304.4) PROTECTION OF SIDES OF EXCAVATION: EXCAVATIONS 5 FEET OR GREATER IN DEPTH REQUIRE PROTECTION METHODS, INCLUDING: -SHORING -BRACING -SHEETING -SHEETING PILING SPECIAL INSPECTION REQUIRED WHEN PROTECTION METHODS EMPLOYED. -ALTERNATIVE: SLOPE SIDE OF EXCAVATION PER SOILS REPORT WITH DOB APPROVAL. 6. PROTECTION OF ADJOINING PROPERTY (3309.4 NYC BC) . RESPONSIBILITY FOR PROTECTION: -THE PERSON CAUSING THE EXCAVATION OR FILL IS RESPONSIBLE TO PROTECT ADJOINING PROPERTIES, REGARDLESS OF DEPTH. -IF THE ADJOINING PROPERTY OWNER REFUSES ACCESS TO PERSON CAUSING EXCAVATION, ADJACENT PROPERTY OWNER IS RESPONSIBLE FOR PROTECTION AND CAN BE ISSUED VIOLATIONS FOR FAILING TO DO SO. PROTECTION REQUIRED (BC 3309.1 ) "ADJOINING PUBLIC AND PRIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION OR DEMOLITION WORK. PROTECTION MUST BE PROVIDED FOR FOOTINGS, FOUNDATIONS, PARTY WALL, CHIMNEYS, SKYLIGHTS AND ROOFS. PROVISIONS SHALL BE MADE TO CONTROL WATER RUN-OFF AND EROSION DURING CONSTRUCTION OR DEMOLITION ACTIVITIES."

1.27-569. WIND LOADS AND EARTHQUAKE LOADS, (A) WIND LOADS. THE STRUCTURAL FRAME AND EXTERIOR COMPONENTS OF ALL BUILDINGS, SIGNS, TANKS AND OTHER EXPOSED CONSTRUCTIONS SHALL BE DESIGNED TO RESIST THE PRESSURES DUE TO WIND AS PRESCRIBED IN REFERENCE STANDARD RS 9-5. WIND SHALL BE ASSUMED TO ACT FROM ANY DIRECTION. FOR CONTINUOUS FRAMING, THE EFFECTS OF PARTIAL LOADING CONDITIONS SHALL BE CONSIDERED. (B) EARTHQUAKE LOADS. EVERY BUILDING, STRUCTURE AND PORTION THEREOF SHALL, AT A MINIMUM, BE DESIGNED AND CONSTRUCTED TO RESIST THE EFFECTS OF SEISMIC GROUND MOTIONS AS PRESCRIBED IN REFERENCE STANDARD RS 9-6. 2. UBC - UNIFORM BUILDING CODE SECTION 2312-1990.

N

PROGRESS INSPECTION ITEMS ITEMS

B.C. SECTION

FOOTING AND FOUNDATION FRAME INSPECTION ENERGY CODE COMPLIANCE INSPECTION FIRE-RESISTANCE RATED CONSTRUCTION

BC 109.3.1 BC 109.3.3 BC 109.3.5 BC 109.3.4

PRE-CONSTRUCTION SURVEY (BC 3309.4): PRE-CONSTRUCTION SURVEYS OF ADJOINING PROPERTIES ARE REQUIRED TO BE SUBMITTED TO DOB PRIOR TO COMMENCEMENT FOR : -EXCAVATIONS BETWEEN 5 & 10 FEET DEEP WITHIN 10 FEET OF AN ADJACENT BUILDING. -ALL EXCAVATION> 10 FEET DEEP. ENHANCED DEMOLITION REQUIREMENTS Categories: - FULL DEMOLITION: THE DISMANTLING. RAZING. OR REMOVAL OF ALL OF A BUILDING OR STRUCTURE, & ALL OPERATIONS INCIDENTAL THERETO. -PARTIAL DEMOLITION: THE DISMANTLING, RAZING, OR REMOVAL OF STRUCTURAL MEMBERS, FLOORS, INTERIOR BEARING WALLS, AND/OR EXTERIOR WALLS OR PORTIONS THEREOF, INCLUDING ALL OPERATIONS INCIDENTAL THERETO.

2. REQUIRED PROGRESS INSPECTIONS. (SECT. 109.3) THE INSPECTIONS SET FORTH 109.3.1 THROUGH 109.3.8 SHALL BE MADE DURING THE PROGRESS OF WORK TO VERIFY SUBSTANTIAL COMPLIANCE WITH THE CODE AND WITH APPROVED CONSTRUCTION DOCUMENTS.

1. GENERAL (SeĐƟon BC 109) EXCEPT AS OTHERWISE SPECIFICALLY PROVIDED, INSPECTIONS REQUIRED BY 2008 NYC BC OR BY DEPARTMENT DURING THE PROGRESS OF WORK MAY BE PERFORMED ON BEHALF OF THE OWNER BY APPROVED INSPECTION AGENCIES OR, IF APPLICABLE, BY SPECIAL INSPECTORS. HOWEVER, IN THE INTEREST OF PUBLIC SAFETY, THE COMMISSIONER MAY DIRECT THAT ANY OF SUCH INSPECTIONS BE PERFORMED BY THE DEPARTMENT. ALL INSPECTIONS SHALL BE PERFORMED AT THE SOLE COST AND EXPENSE OF THE OWNER. REFER TO CHAPTER 1 OF TITLE 28 OF THE ADMINISTRATIVE CODE OF 2008 NYC BC, FOR ADDITIONAL PROVISIONS RELATING TO INSPECTIONS.

THE DEMOLITION SAFETY REQUIREMENTS APPLY WHENEVER ANY DEMOLITION OPERATIONS ARE BEING PERFORMED, REGARDLESS OF THE PERMIT TYPE ISSUED.

3. A LOG OR OTHER DOCUMENTATION SHALL BE MAINTAINED AT THE JOB SITE INDICATING THE DATES WHEN CONTROLLED INSPECTIONS WERE PERFORMED, THE IDENTITY OF THE INSPECTOR, AND THE SCOPE OF THE WORK WHICH WAS PERFORMED.

DEMOLITION NOTIFICATION -DEPARTMENT NOTIFICATION -AT LEAST 24 HOURS IN ADVANCE, BUT NOT MORE THAN 48 HOURS PRIOR TO COMMENCING EITHER FULL OR PARTIAL DEMOLITION OPERATIONS.

4. WHEN A "TR-1" CONTROLLED INSPECTION FORM IS FILED AT THE BUILDING DEPARTMENT, SUCH FORM SHALL BE ACCOMPANIED BY A REPORT WHICH SHALL INCLUDE THE DATES OF INSPECTIONS, THE IDENTITY OF THE INSPECTOR, AND THE SCOPE OF WORK WHICH WAS OBSERVED. 5. WHEN A TRADE INSTALLING MECHANICAL WORK CAUSES STRUCTURAL MEMBERS OR RATED ASSEMBLIES TO LOSE THEIR INTEGRITY, REPAIRS SHALL BE PERFORMED UNDER THE SUPERVISION OF A DESIGNATED PERSON. 6. BUILDING DEPARTMENT INSPECTORS SHALL REVIEW RECORDS AT JOB SITES TO MAKE CERTAIN THAT THERE IS ADEQUATE SELF-INSPECTION. 7. AS PER CHAPTER 1 OF TITLE 28-116.2.3 OF THE ADMINISTRATIVE C ODE OF 2008 NYC BC THE PERMIT APPLICATION SHALL SET FORTH AN INSPECTION PROGRAM FOR THE JOB. SUCH INSPECTORS MAY BE MADE BY APPROVED AGENCIES OR BY THE DEPARTMENT AS PROVIDED IN THIS CODE OR IN THE RULES OF THE DEPARTMENT. SPECIAL INSPECTIONS SHALL BE PERFORMED ONLY BY INDIVIDUALS WHO ARE SPECIAL INSPECTORS. THE PERMIT HOLDER SHALL NOTIFY THE RELEVANT SPECIAL INSPECTORS IN WRITING AT LEAST 72 HOURS PRIOR TO THE COMMENCEMENT OF ANY WORK REQUIRING SPECIAL INSPECTION. -THE NAME AND BUSINESS ADDRESSES OF SPECIAL INSPECTORS AND APPROVED AGENCIES SHALL BE SET FORTH IN THE WORK PERMIT APPLICATION. -A RECORD OF ALL INSPECTIONS SHALL BE KEPT BY THE PERSON PERFORMING THE INSPECTION. -THE COMMISSIONER MAY REQUIRE INSPECTION REPORTS TO BE FILED WITH THE DEPARTMENT. - RECORDS OF INSPECTIONS MADE BY APPROVED AGENCIES AND SPECIAL INSPECTORS SHALL BE MAINTAINED BY SUCH PERSONS FOR A PERIOD OF SIX YEARS AFTER SIGN-OFF OF THE JOB OR FOR SUCH OTHER PERIOD OF TIME AS THE COMMISSIONER MAY REQUIRE AND SHALL BE MADE AVAILABLE TO THE DEPARTMENT UPON REQUEST.

THIS CONTRACTOR SHALL INSTALL, MAINTAIN AND SUBSEQUENTLY REMOVE ALL SCAFFOLDING AS REQUIRED. SCAFFOLDING SHALL CONFORM TO ALL APPLICABLE OSHA AND NEW YORK CITY BUILDING DEPARTMENT REGULATIONS. ALL COSTS FOR SCAFFOLDING ARE INCLUDED IN THE CONTRACT AMOUNT. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL DEBRIS GENERATED BY THE OPERATION IN A SAFE AND LEGAL MANNER.

INDIVIDUAL PILE CAPS AND CAISSONS OF EVERY STRUCTURE SUBJECTED TO SEISMIC FORCES SHALL BE INTERCONNECTED BY TIES. SUCH TIES SHALL BE CAPABLE OF RESISTING, IN TENSION OR COMPRESSION, A MINIMUM HORIZONTAL FORCE EQUAL TO THE PRODUCT OF (ZV4) AND THE LARGER VERTICAL LOAD AT THE END OF EACH TIE.

THE CONTRACTOR SHALL BE RESPONSIBLE, AT NO ADDITIONAL COST FOR PROVISION, UPKEEP, MAINTENANCE AND SUBSEQUENT REMOVAL OF THE FOLLOWING TEMPORARY FACILITIES: A. TOILETS FOR PERSONNEL. B. BARRIERS AND RAILINGS ON-SITE AND WITHIN THE BUILDING FOR SAFETY OF PERSONNEL. C. ALL SUCH PROTECTION AND TEMPORARY FACILITIES MENTIONED ABOVE SHALL MEET OSHA AND/OR NEW YORK CITY REGULATIONS. 7. PROVIDE FOR CONSTRUCTION OF A JOB FENCE, EIGHT (8) FEET TALL, WITH TOP AND BOTTOM RAILS. INSTALL A GATE WITH HASPS AND LOCKS OF SUFFICIENT STRENGTH TO WITHSTAND CONSTANT USE WHERE SHOWN ON THE DRAWINGS AND IN LOCATION(S) AGREED UPON JOINTLY BY OWNERS' REPRESENTATIVE AND THE CONTRACTORS. 8. THIS CONTRACTOR WARRANTS THAT HE HAS INSPECTED THE SITE AND HAS CAREFULLY EXAMINED THE WORK FOR SCOPE AND DIFFICULTY OF EXECUTION, AND HAS REVIEWED THE SITE SURVEYS ATTACHED HERETO, SPECIFICATIONS AND BORING DATA.

D

C

B

STRUCTURALENGINEER:

MUNICIPALCONSULTANT:

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

DESIGNCONSULTANT:

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DRAWING TITLE: CODE ANALYSIS

NOTE: ENTIRE BUILDING TO BE FULLY SRPINKLED.

ITEMS TO BE FILED SEPARATELY ITEM BPP APPLICATION SEWER CONNECTION SD 1 & 2 SPRINKLERS STRUCTURAL FOUNDATION BOILER FIRE ALARM FENCE SHED

SEALANDSIGNATURE

NOTE - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION - TO BE FILED UNDER SEPARATE APPLICATION

9. THIS CONTRACTOR SHALL CLEAN AND BROOM SWEEP SIDEWALKS UPON THE COMPLETION OF EACH DAY'S WORK.

E

DATE

HVAC & SERVICE WATER HEATING EQUIPMENT HVAC & SERVICE WATER HEATING CONTROLS DUCT PLENUM AND PIPING INSULATION AND SEALING PROTECTION OF FOUNDATION INSULATION INSULATION PLACEMENT & R VALUES FENESTRATION THERMAL VALUES & RATING FENESTRATION VALUES FOR AIR LEAKAGE FENESTRATION AREAS AIR SEALING & INSULATION - VISUAL ELECTRICAL METERING LIGHTING IN DWELLING UNITS INTERIOR LIGHTING POWER EXTERIOR LIGHTING POWER LIGHTING CONTROLS MAINTAINANCE INFORMATION PERMANENT CERTIFICATE

# 1 2 3 4

REVISIONS DESCRIPTION

KEYPLAN

TR8 INSPECTIONS TR8 INSPECTION

TR8 # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com NO.

SPECIAL INSPECTION NOTES:

INCLUDED IN THIS AGREEMENT IS THE RESPONSIBILITY OF THIS CONTRACTOR IN THE OBSERVANCE OF RELEVANT PROVISIONS OF THE FOLLOWING: A. FEDERAL OSHA REGULATIONS. B. NEW YORK CITY BUILDING DEPARTMENT AND CODE REGULATIONS. C. ENVIRONMENTAL PROTECTION AGENCY REGULATIONS. D. ANSI-A10.5-1975 SAFETY REQUIREMENTS FOR MATERIAL HOISTS. E. A 10.6-1969AMERICAN NATIONAL STANDARD SAFETY REQUIREMENTS FOR DEMOLITION. F. A 10.10-1970 SAFETY REQUIREMENTS FOR TEMPORARY AND PORTABLE SPACEHEATING DEVICES AND EQUIPMENT USED IN THE CONSTRUCTION INDUSTRY. G. Z 49.2 STANDARD FOR SAFEGUARDING BUILDING CONSTRUCTION AND DEMOLITION OPERATIONS.

FOUNDATION PLATES OR SELLS SHALL BE BOLTED TO THE FOUNDATION OR FOUNDATION WALL WITH NOT LESS THAN ONE-HALF INCH NOMINAL DIAMETER STEEL BOLTS EMBEDDED AT LEAST SEVEN INCHES INTO THE CONCRETE OF MASONRY RUED SPACED NOT MORE THAN SIX FEET APART. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIECE WITH ONE BOLT LOCATED WITHIN TWELVE INCHES OF EACH END OF EACH PIECE, A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH BOLT TO THE PLATE. 5. FOUNDATION INTERCONNECTION OF PILE CAPS AND CAISSONS.

BC 1704.3.1 BC1704.13, BC1704.3.3 BC 1704.3.4 BC 1704.4 BC 1905.6 BC 1905.3 BC 1704.5 BC 1704.7.1 BC 1704.7.4 BC 1704.5 BC 1704 .19 BC1704.19, 3304.4.1 BC 1704.20 BC 1704.25 BC 1704.9.1 BC 1704.12

PHYSICAL EXAMINATION OF ADJOINING PROPERTIES IS REQUIRED: ( BC 3309.3): - PRIOR TO COMMENCEMENT OF WORK - DURING THE PROGRESS OF WORK CONDITIONS OBSERVED ARE REQUIRED TO BE DOCUMENTED & MADE AVAILABLE TO DOB UPON REQUEST.

ADJACENT PROPERTY OWNERS -WRITTEN NOTICE AT LEAST 10 DAYS IN ADVANCE OF FULL OR PARTIAL DEMOLITION OPERATIONS. -EXCEPTION: PARTIAL INTERIOR DEMOLITION OPERATIONS, WHERE ONLY HAND-HELD MECHANICAL DEMOLITION EQUIPMENT IS USED. MECHANICAL DEMOLITION THE USE OF MECHANICAL DEMOLITION EQUIPMENT, OTHER THAN HAND-HELD EQUIPMENT, IN FULL AND PARTIAL DEMOLITION OPERATIONS. - CONSTRUCTION DOCUMENTS SHALL BE FILED BY A REGISTERED PROFESSIONAL ENGINEER. - MECHANICAL PARTIAL & FULL DEMOLITION WITHIN THE BUILDING ARE SUBJECT TO SPECIAL INSPECTION.

(I) SOILS OF CLASSES 7-65,8-65,10-65 AND NON-COHESIVE CLASS 11-65 BELOW THE GROUND WATER TABLE AND LESS THAN FIFTY FEET BELOW THE GROUND SURFACE SHALL BE CONSIDERED TO HAVE POTENTIAL FOR LIQUEFACTION. 4. FOUNDATION PLATES AND SILLS.

BC

STRUCTURAL STEEL-WELDING STRUCTURAL STEEL-ERECTION & BOLTING STRUCTURAL COLD FORMED STEEL CONCRETE CAST IN PLACE CONCRETE TEST CYLINDERS TR-2 CONCRETE DESIGN MIX TR-3 MASONRY SOILS - SITE PREPARATION SOILS - INVESTIGATIONS (BORING/TEST PITS) TR-4 MECHANICAL SYSTEMS STRUCTURAL SAFETY - STRUCTURAL STABILITY EXCAVATION - SHEETING - SHORING & BRACING SITE STORM DRAINAGE DISPOSAL & DETENTION SYSTEM INST. FIRESTOPS,DRAFTSTOPS & FIREBLOCK SYSTEMS UNDERPINNING EXTERIOR INSULATION FINISH SYSTEMS (EIFS)

5. SAFETY IN EXCAVATIONS: (BC 3304) NOTIFICATION OF DEPARTMENT (BC3304.3.1) Via Phone or Electronically, by the Permit Holder. - NOTIFICATION TO DOB REQUIRED AT LEAST 24 HOURS IN ADVANCE, BUT NO MORE THAN 48 HOURS PRIOR TO COMMENCEMENT OF EARTHWORK OPERATIONS. EXECPTIONS: -HAND EXCAVATION 5 FEET OR LESS, & 2 FEET OR MORE FROM AN EXISTING FOOTING, AND NOT IN A BASEMENT OR CELLAR THAT ADJOIN AN EXISTING FOUNDATION. - GEOTECHNICAL TEST PITS 1 0 FEET OR LESS IN PLAN - BURIAL IN CEMETERIES . - HPD EMERGENCY WORK NOTIFICATION OF ADJACENT BUILDING OWNERS (3304.3.2)

3. B. LIQUEFACTION.

1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

3. RESPONSIBILITY FOR SAFETY (BC 3301.1.1) AS PER THIS chapter 33, "NOTHING IN THIS CHAPTER SHALL BE CONSTRUED TO RELIEVE PERSON ENGAGED IN CONSTRUCTION OR DEMOLITION OPERATIONS FROM COMPLYING WITH OTHER APPUCABLE PROVISIONS OF LAW, NOR IS IT INTENDED TO ALTER OR DIMINISH ANY OBLIGATION OTHERWISE IMPOSED BY LAW ON THE OWNER, CONSTRUCTION MANAGER, GENERAL CONTRACTOR, CONTRACTORS, MATERIAL MEN, REGISTERED DESIGN PROFESSIONALS, OR OTHER PARTY INVOLVED IN A CONSTRUCTION OR DEMOLITION PROJECT TO ENGAGE IN SOUND DESIGN & ENGINEERING, SAFE CONSTRUCTION OR DEMOLITION PRACTICES, INCLUDING BUT NOT LIMIT TO DEBRIS REMOVAL, & TO ACT IN A REASONABLE & RESPONSIBLE MANNER TO MAINTAIN A SAFE CONSTRUCTION OR DEMOLITION SITE."

THE FOLLOWING TYPES OF CONSTRUCTION SHALL, AT A MINIMUM BE DESIGNED AND CONSTRUCTED TO RESIST THE EFFECTS OF SEISMIC GROUND MOTIONS AS PROVIDED IN THIS SECTION: NEW STRUCTURES ON NEW FOUNDATIONS; NEW STRUCTURES ON EXISTING FOUNDATIONS; AND ENLARGEMENTS IN AND OF THEMSELVES ON NEW FOUNDATIONS. BUILDINGS CLASSIFIED IN NEW YORK CITY OCCUPANCY GROUP J-3 ACID NOT MORE THAUL THREE STORIES IN HEIGHT NEED NOT CONFORM TO THE PROVISIONS OF THIS SECTION.

BC 1107.2.4 ALL OPERABLE WINDOWS IN ROOM OR SPACES IN TYPE B DWELLING UNIT OR SLEEPING UNIT SHALL HAVE OPERABLE PARTS COMPLYING WITH SECTION 309(OPERABLE PARTS) OF ICC A117.1

Key Name

2. SAFEGUARDS DURING CONSTRUCTION OR DEMOLITION: THE PROVISIONS OF CHAPTER 33 OF THE 2008 NYC BUILDING CODE SHALL GOVERN THE CONDUCT OF ALL CONSTRUCTION OR DEMOLITION OPERATIONS WITH REGARD TO THE SAFETY OF THE PUBLIC & PROPERTY. FOR REGULATIONS RELATING TO THE SAFETY OF PERSONS EMPLOYED IN CONSTRUCTION OR DEMOLITION OPERATIONS, OSHA STANDARDS SHALL APPLY & IN CONFORMANCE WITH THE NEW YORK CITY FIRE.

BC 2113.1.6.5 REFUSAL OF CONSENT. IF CONSENT IS NOT GRANTED BY THE OWNER OF THE PREVIOUSLY CONSTRUCTED BUILDING TO DO THE ALTERATION WORK REQUIRED BY THIS SECTION, SUCH OWNER SHALL SIGNIFY HIS OR HER REFUSAL IN WRITING TO THE OWNER OF THE NEW OR ALTERED BUILDING AND TO THE COMMISSIONER; AND THE OWNER OF THE NEW OR ALTERED BUILDING HAVING SUBMITTED PLANS THAT CONFORM TO THE REQUIREMENTS OF THIS SECTION, SHALL THEREUPON BE RELEASED FROM ANY RESPONSIBILITY FOR THE PROPER OPERATION OF THE EQUIPMENT DUE TO LOSS OF DRAFT AND FOR ANY HEALTH HAZARD OR NUISANCE THAT MAY OCCUR AS A RESULT OF THE NEW OR ALTERED BUILDING.

1 1 1

TABLE 602 - FIRE RESISTANCE RATING REQUIREMENT FOR EXTERIOR WALL BASED ON FIRE SEPARATION DISTANCE OCCUPANCY GROUP A, B, E, F-2. FIRE SEPARATION TYPE OF CONSTRUCTION I, R, S-2,U

NATURAL VENTILATION REQUIREMENTS AS PER BC 1203. NATURAL LIGHT AND VENTILATION HAS TO BE PROVIDED THROUGH LEGAL WINDOW. MAXIMUM DEPTH OF A ROOM IS 30 FEET FROM OUTER FACE OF THE WINDOW.

COMPLY WITH THE FOLLOWING SECTIONS OF THE MDL: · MDL33- KITCHEN WALL-ONE HOUR RATED · MDL35- PROVIDE AT LEAST 5 SQUARE OF GLAZED SURFACE ENTRANCE HALL DOOR. · MDL51A-PEEPHOLES MDL57-MAIL BOXES

BC 2113. 1.6 ADJOINING CHIMNEYS AND VENTS.

SPECIAL INSPECTION

1. THIS WORK WILL BE PERFORMED IN COMPLETE COMPLIANCE WITH FEDERAL OSHA STANDARDS THE ADMINISTRATIVE CODE OF THE CITY OF NEW YORK, DEP REGULATIONS REGARDING DISPOSAL OF SOIL, THE NEW YORK CITY FIRE, AND THOSE OF ALL OTHER AGENCIES HAVING JURISDICTION OVER THIS PROJECT.

REQUIREMENT

BC CHAPTER 12 INTERIOR ENVIRONMENT

5

4

A

B SAFETY NOTES PROTECTION OF ADJACENT PROPERTY (BC3309)

CODE ANALYSIS ITEM

page | 7

DATE

2ND - 4TH FLOOR AREA PLAN (TYP.)

8'-11 1/4"

W (W) W/ W.C. WD W.H. W/O WT.

REVISIONS DESCRIPTION

52'-1"

8'-4 1/4"

VERTICAL VESTIBULE VERIFY IN FIELD VOLUME

Y TOP AND BOTTOM TECHNICAL TELEPHONE TEMPERED TEMPERED GLASS THICK(NESS) TYPICAL TO BE DETERMINED TO BE SELECTED

U

UTIL. U.O.N.

VERT. VEST. V.I.F. VOL.

NO.

2'-0"

6 SF

5'-11"

MECH. DEDUCTION

2"

V SOUTH SOLID CORE SCHEDULE SECTION SHEET SIMILAR SQUARE SQUARE FEET STAINLESS STEEL STANDARD STRUCTURAL SUSPEND(ED) SYMMETRICAL SYSTEM

SPENCER

2'-0"

4 SF

28'-10"

12'-4" 6"

3'-10"

6'-2"

8'-11"

4 SF

2"

DENSITY DEDUCTION MECH. 12 SF DEDUCTION

1'-10 1/2"

3'-10"

MECH. DEDUCTION

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

5'-0"

5'-0"

TYP. NET FLOOR AREA (2ND - 4TH FL.) 1,476 SF

6"

8'-9 1/4"

(S) S.C. SCHED. SECT. SHT. SIM. SQ. SF S.S. STD. STRUCT. SUSP. SYMM. SYS.

DIEGO AGUILERA ARCHITECTS, P.C.

STREET

8'-3"

16'-6"

2'-0"

3'-10"

5'-11"

11'-1"

2'-0"

3'-10"

8"

EAST ELECTRIC ELEVATION ENGINEER EQUAL EQUIPMENT EXHAUST EXISTING EXTERIOR ELECTRICAL

P.LAM. PLAS. PLY. PNL. PR. PREFAB. PTN. PTD. Q

S OVERALL ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING OPPOSITE ORIGINAL

(50'-0" WIDE)

B

2"

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

3'-0"

E

JANITOR

O.A. O.C. O.D. O.H. OPNG. OPP. ORIG. P

132'-8".

C

2'-0"

MUNICIPALCONSULTANT:

3'-10"

BOARD BUILDING BLOCKING BRACKET BRONZE

O INSIDE DIAMETER INCLUDE(D)(ING) INFORMATION INCANDESCENT

TO CORNER

A

5'-11"

16'-10"

5

REAR YARD

BD. BLDG. BLKG. BRKT. BRZ.

F.F. FIN. FLR. FLUOR. F.O.W. FPSC FR. FT. F.T. FURR. G

I I.D. FIRE ALARM INCL. FABRICATE INFO. FIRE EXTINGUISHER INCAN. FIRE EXTINGUISHER CABINET J FINISH FLOOR FINISH(ED) JAN. FLOOR L FLUORESCENT FACE OF WALL FIRE PROOF SELF-CLOSING LAM. LB. (OR #) FRAME L.H. FOOT OR FEET FIRE-TREATED FURRING M

25'-0"

B

DIEGO AGUILERA ARCHITECTS, P.C.

REVISION INDICATOR

?

DOOR NUMBER

?

F.ALM. FABR. F.E. F.E.C.

DATE: 8/11/2013 8:39:05 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

SHEET 2 OF 18

52'-1"

7'-11"

CONCRETE MASONRY UNITS

F DOUBLE DEPARTMENT DETAIL DIAMETER DIMENSION DIVISION DOWN DOOR DRAWING DRAWER

BASE PLANE CALCULATION: 41.92' + 41.86' = 41.89' (BASE PLANE)

C

3/ 8"

MECH. VENT

DBL. DEPT. DET. DIA. DIM. DIV. DN. DR. DWG. DRW.

SEALANDSIGNATURE

STRUCTURALENGINEER:

28'-10"

MV

BRICK

AIR CONDITIONING ACOUSTICAL ADJUSTABLE ALUMINUM ALTERNATE ANODIZED APPROVED APPROXIMATE ARCHITECT(URAL) AVERAGE ABOVE FINISH FLOOR

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DRAWING TITLE: ZONING ANALYSIS, SITE PLAN, & HEIGHT & SETBACK DIAGRAMS

1'-11"

E

B.C: EL: + 41.18'

SCALE: 3/16" = 1'-0"

T.C: EL: + 41.45'

SITE PLAN

3

D

A A/C ACOUS. ADJ. ALUM. ALT. ANOD. APPD. APPROX. ARCH. AVG. A.F.F. B

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

Z-100.00 6'-0"

NEW TREE PER ZR 26.41

1

24'-6"

WINDOW SYMBOL

BACKFILL (new)

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

BC 508.5.1 BUILDING ENTRANCE IS WITHIN 250 FT OF A FIRE HYDRANT

EL: + 41.92'

CELLAR & 1ST FLOOR PLAN 2ND - 4TH FLOOR & ROOF PLAN ELEVATIONS ELEVATIONS SECTIONS DETAILS DETAILS ADA DETAILS DOOR & WINDOW SCHEDULES, & DETAILS ENERGY ANALYSIS GENERAL NOTES PLUMBING & GAS RISER DIAGRAM, & NOTES TITLESHEET ZONING ANALYSIS, SITE PLAN, & HEIGHT & SETBACK DIAGRAMS AREA PLANS CODE ANALYSIS ZONING ZD-1

2'-0"

?

NORTH ARROW

DESIGNCONSULTANT:

42'-0 5/8" TO FIRE HYDRANT

PLANTING PER ZR 23-03

DN

EL: + 40.27'

ADJACENT 3 STORY & ATTIC FRAME RESIDENCE

ABBREVIATIONS

N

B.C: EL: + 41.08'

EL: + 41.86'

#221 SPENCER STREET NEW 4 STORY & CELLAR BUILDING CONST. CLASS: II-A OCCUPANCY CLASS: R-2 USE GROUP: 2 8 CLASS 'A' APARTMENTS

8'-3"

1

DRAWING LIST SHEET NAME

CONCRETE SIDEWALK

BALCONY 74 SF

12'-4"

REAR YARD

BALCONY 74 SF

LOT COVERAGE CALC. BUILDING: 28.83' X 52.08' = 1,501 SF 74 SF X 2 = 148 SF 2ND FL. BALCONIES TOTAL LOT COVERAGE = 1,649 SF < 1,729 OK

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

HARD WIRED SMOKE & CARBONMONOXIDE DETECTOR SHALL COMPLY TO NYC REG.

T.C: EL: + 41.32'

BULKHEAD ACCESS TO ROOF PLANTING PER ZR 23-03

4

EARTH (exisƟng) SD CMD

SPENCER STREET

14'-0"

RAILING

SCALE: 12" = 1'-0"

LEGEND

ZR 43-02: 2 NEW STREET TREES ARE REQUIRED BY ZR23-03 OR ZR33-03, EXACT LOCATION TO BE DETERMINED BY DEPARTMENT OF PARKS RECREATION.

6'-0"

DESIGNCONSULTANT:

2

22'-0 1/2"

1'-11" 8'-3"

STAIR BELOW GRADE

8'-11"

SITE MAP

6'-0"

4'-0"

8'-6 3/4"

3

Z-101.00 Z-102.00 Z-103.00 ZD-1 Grand total: 18

4'-0"

7'-11"

T-100.00 Z-100.00

22'-0 1/2"

2'-0"

EN-100.00 G-100.00 P-100.00

BUILDING

FRONT YARD 15'-11"

EL: + 40.13'

8'-3"

SITE LOCATION

3

2

12'-4"

A-100.00 A-101.00 A-200.00 A-201.00 A-202.00 A-300.00 A-301.00 A-302.00 A-303.00

52'-1"

REAR YARD 26'-0"

N

REAR YARD

SHEET NUMBER

41'-11"

KEYPLAN

8'-3"

4

221 SPENCER STREET, BROOKLYN, NY 11205 1763 3 R6B 17A 2,883 SF 2 IIA R-2

28'-10"

ADDRESS BLOCK LOT ZONING DISTRICT ZONING MAP LOT AREA USE GROUP CONSTRUCTION CLASS OCCUPANCY GROUP

EXISTING VACANT LOT

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

N

SITE INFORMATION

A

DATE: 8/11/2013 8:39:15 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

Z-102.00 SHEET 4 OF 18


A

2 A-202.00

14'-10"

W4

SEALANDSIGNATURE

A-202.00

REAR ELEVATION SCALE: 1/4" = 1'-0"

DATE: 8/11/2013 8:37:55 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

WINDOW WELL

A

CL

A 4"

2'-4" 6 7/8"

BATH

A MV

4"

5'-5"

9"

5'-5"

4"

D

C

6'-4 1/2"

DN

2'-5"

9'-3 1/2"

A

1'-4"

TYPES

FLOOR/CEILING ASSEMBLY DETAIL ROOF ASSEMBLY DETAIL U.L. DESIGN NO. U419 MEA# BSA #338-78-SM (TYP.) 408-89-M (APP)

3" THERMAFIBER SOUND ATTENUATION BLANKET

1" TREATED WOOD BLOCKING

2" THERMAFIBER SOUND ATTENUATION BLANKET

CEILING AS SCHEDULED

2" E.I.F.S.

PROVIDE THRU-WALL ALUMINUMCAP RECEIVER, FLASHING AND COUNTER FLASHING AT ALL PARAPET ROOF JUNCTURES CARRY-UP BASE FLASHING 8"MIN. PROVIDE CONT. CANT STRIP AT ALL PARAPET ROOF JUNCTURES

1 LAYERS 5/8" GYP. BD. EACH SIDE

CONTINUOUS ACOUSTIC CAULKING AT ALL JOINTS BOTH SIDES

NO.

UL DESIGN:

U419

STC:

51

STC:

59

NOTES:

AT BATHS. & PWD. RMS. : USE 1 LAYER 5/8" W.R. GYP BD. & 1 LAYER 5/8" GYP BD. WITH CERAMIC TILE INSTALL CEMENT BD. INSTEAD OF GYP. BD. AT TUB LOCATION. WATERPROOFING MEMBRANE TURN UP 4" ABOVE FIN. FLR.

NOTES:

AT BATHS. & PWD. RMS. : USE 1 LAYER 5/8" W.R. GYP BD. & 1 LAYER 5/8" GYP BD. WITH CERAMIC TILE INSTALL CEMENT BD. INSTEAD OF GYP. BD. AT TUB LOCATION. WATERPROOFING MEMBRANE TURN UP 4" ABOVE FIN. FLR.

AT KITCHEN CABINETS USE 3-5/8" METAL STUDS @ 12" O.C.

AT KITCHEN CABINETS USE 3-5/8" METAL STUDS @ 12" O.C. LOCATION:

WITHIN APARTMENTS

LOCATION:

INTERIOR WALL

A

B

MEMBRANE FLASHING OVER METAL FLASHING

U493

GALVANIZED STRUCTURAL STEEL ANGLE FOR MASONRY SUPPORT WELD TO TUBE WITH SPACER

LOCATION:

2 HOUR INTERIOR WALL

C

CHASE WALL

ELASTOMETRIC SEALANT WITH 3/4" BACKER ROD

B

2" E.I.F.S.

R -15 BATT INSULATION

SD CMD

5/8" GYP ON METAL STUD

AIR AND VAPOR BARRIER

2

FLOOR FINISH TO BY OWNER

1/2" SHEAR STUDS WELDED TO CORRUGATED MTL. DECKING @ 12" O.C.

W1

REAR YARD

STRUCTURALENGINEER:

2

BC 27-859 CHIMNEY TO EXTEND 3' ABOVE HIGHEST CONSTRUCTION WITHIN 10' OF CHIMNEY OUTLET

DURA-VENT APPROVED GAS VENT BSA CAL. # 569-57-SM

A-202.00

* CONC. SLAB OVER GALV. MTL. DECK BSA #338-78-SM (TYP.)

FIRE STOPPING

MUNICIPALCONSULTANT: 7/8" FURRING CHANNELS PERPENDICULAR TO F.J. @ 16" O.C.

TALL CONE BOOT FLASHING RING FASTENED TO ROOF SHEATING

ROOFING

TYP. GYPSUM BOARD HUNG CEIL. DETAIL

TYP. FIRE RETARD ALL CEILINGS W/ (2) LAYER 1/2" TYPE 'X' GYP. THROUGHOUT U.L. DESIGN NO. U419 MEA573-06-M 5/8" GYP ON METAL STUD

SCALE: 1 1/2" = 1'-0"

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

4" CONCRETE SLAB ON CORRUGATED STEEL DECK ON TOP OF STEEL JOISTS AS INDICATED ON STRUCTURAL PLANS ROOF BEAMS (TYP.)

DOUBLE JOIST EA. SIDE

FLOOR FINISH TO BY OWNER 1/4" GROUT

8" C.M.U. 1" MIN. AIR SPACE

1/2" SHEAR STUDS WELDED TO CORRUGATED MTL. DECKING @ 12" O.C.

1ST FLOOR

2

DESIGNCONSULTANT:

GYP. BD. CEIL'G ASSEMBLY

12" CONCRETE FOUNDATION WALL

POURED CONCRETE FOOTING (REFER TO STRUCTURAL)

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

1/8"SATURATED BENTONITE CLAY GEOTEXTILE MEMBRANE

3

METAL CHIMNEY (GAS VENT) DOUBLE WALL CONSTR.: OUTER WALL #28 GA. GALV. STEEL INNER WALL = .16 ALUMINUM

FLOOR FINISH TO BY OWNER

MV

A

SD CMD

A

W1

UP

UP

UP

OPEN CELLAR

CELLAR MAY NOT BE USED FOR LIVING OR SLEEPING ROOMS AND SHALL NOT BE RENTED SEPARATELY

NOTE: CELLAR TO BE FULLY WATERPROOFED

H

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

2 A-202.00

1'-0"

24'-5 1/2"

6"

CELLAR

8"X8" CROSSREINFORCEMENT (MIN 2" FROM FINISH EDGE, USE #6 REBAR)

SEALANDSIGNATURE

STRIPPING FELTS 14" x 14" CROSSREINFORCEMENT (USE #8 REBAR)

DATE: 8/11/2013 8:38:19 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DRAWING TITLE: CELLAR & 1ST FLOOR PLAN

24'-9 1/2"

SEALANDSIGNATURE

SCALE: 1 1/2" = 1'-0"

4 E

D

C

1

51'-9"

SCALE: 3/4" = 1'-0"

B

A

E D

C

B

D

CELLAR PLAN SCALE: 1/4" = 1'-0"

DATE: 8/11/2013 8:37:40 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

A-100.00

SHEET 12 OF 18

WALL DETAIL

1

E

6'-0"

ADJACENT 3 STORY FRAME RESIDENCE

A-300.00

2" INSULATION 1/8" BENTONITE CLAY SATURATED GEOTEXTILE MEMBRANE

ROOF DRAIN DETAIL

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

DRAWING TITLE: DETAILS

1/4" GROUT

1/2" MOVEMENT JOINT @ EDGE OF SLAB (USE ELASTOMETRIC FILLER)

CHIMNEY DETAIL SCALE: 3/4" = 1'-0"

TAPER INSULATION TO DRAIN

SHEET 7 OF 18

1 A-202.00

C

B

A

A DIEGO AGUILERA ARCHITECTS, P.C.

ENERGY CONSTRUCTION NOTES - NYS ENERGY CODE (2010 EDITION) DEGREE DAYS: 4910 DESIGN METHOD: THERMAL RATING MEANS OF COMFORT HEATING: GAS FIRED H.W. DESIGN TEMPERATURE DIFF: 70 DEGREES ENERGY CONSTRUCTION NOTES: GENERAL CRITERIA FOR COMMERCIAL BUILDINGS AS PER THE ENERGY CONSERVATION CONTRUCTION CODE OF NYCECC 2011 1. THE FOLLOWING AREAS OF GLAZING AS A TOTAL PERCENTAGE OF THE TOTAL WALL AREA SHALL BE USED TO DETERMINE THE MAX U-COMMERCIAL- 3 STORIES OR MORE: LESS THAN OR EQUAL TO 40%%% WINDOW/WALL RATIO SHALL BE PRESCRIBED AS IN TABLE 502.3 AND IN A MANNER MANNER THAT PROVIDES CONTINUITY OF INSULATION AT PLATE LINES, SILL LINES AND CORNERS. 2. ALL INSULATION WHICH IS CAPABLE OF ABSORBING WATER SHALL BE PROTECTED BY A VAPOR BARRIER LOCATED ON THE WINTER WARM SIDE OF THE INSULATION. 3. MANUFACTURED DOORS AND WINDOW SHALL HAVE AIR INFILTRATION RATED NOT EXCEEDING THE FOLLOWING: A) WINDOWS - CFM PER LINEAR FT. OF OPERABLE SASH CRACK - 0.5 B) DOORS - CFM PER S.F. AREA SLIDING GLASS - 0.5 SWINGING 1.0 C) INFILTRATION WHEN TESTED AT PRESSURE DIFFERENTIAL OF 1.567 LB/FT WHICH IS EQUIVALENT TO THE IMPACT PRESSURE OF 25 MPH WIND AIR LEAKAGE (MANDATORY).

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

4. EXTERIOR JOINTS AROUND WINDOWS AND FRAMES, OPENINGS BETWEEN WALLS AND ROOF/CEILINGS AND WALL PANELS, OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED. SITE CONSTRUCTED DOORS AND WINDOWS SHALL BE SEALED AS PER ABOVE. 5. PIPING INSULATION: A) ALL PIPING INSTALLED TO SERVICE BUILDINGS AND WITHIN BUILDINGS SHALL BE THERMALLY INSULATED AS PER SEC. 504.5 OF NY ENERGY CONSERVATION CONSTRUCTION CODE. PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS,

NO.

6. TABLE 502.1.1 MULTIPLE SINGLE FAMILY DWELLINGS: SECTION 503.2.3, & 504 WINDOW AREA < 40%%% OF GROSS EXTERIOR WALL AREA A) HEATING DEGREE DAYS: 4,500 - 4,999 B) MAXIMUM GLAZING U FACTOR: .70 B.1) MAXIMUM GLAZING U FACTOR FOR ENTRANCE DOOR: .85 C) MINIMUM CEILING R-VALUE: R-38 D) MINIMUM EXTERIOR WALL R-VALUE: R-19 E) MINIMUM WOOD JOIST FLOOR R VALUE: R-30 F) MINIMUM BASEMENT R VALUE: R-10/13 H) MINIMUM SKYLIGHT U FACTOR: U=.60 7. CONTRACTOR SHALL BE RESPONSIBLE FOR AND COMPLY WITH ALL THE APPLICABLE LAWS, ORDINANCE RULES AND REGULATIONS OF THE NYSECC AND SHALL PROVIDE ALL THE CRITERIA AS OUTLINED IN THESE GENERAL NOTES AS PERTAINS TO RELATED EQUIPMENT, MATERIALS AND THEIR INSTALLATION AT JOB SITE.

REVISIONS DESCRIPTION

DATE

KEYPLAN

8. INSULATION MATERIALS- NYS ADMIN. CODE SEC. C26-1409.3 (27-811) A) ALL INSULATION SHALL BE OF NON-COMBUSTABLE MATERIAL B) ALL MATERIAL COVERINGS, VAPOR BARRIERS AND ADHESIVES SHALL HAVE A FLAME SPREAD RATING NO HIGHER THAN 25 AND A SMOKE DEVELOPED RATING NO HIGHER THAN 50.

4

MV

DESIGNCONSULTANT:

4" INSULATED SLAB

DECK CLAMP

5

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

H FD H

1/2" NON-SHRINKIN EPOXY GROUT

FIN. TYPE FLOORING ON SUB-FLOORING (TYPICAL)

CLAMPING RING

MINERAL FIBER FIRESTOP TO FULL LENGTH OF BEAMS ALL AROUND AT EACH FLOOR (TYPICAL)

A

W1

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

BEARING PLATE

A

B

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

4'-4" EXISTING CONCRETE SIDEWALK 4" METAL STUDS WITH 2 LAYER 5/8 GYPSUM BOARD ON EACH SIDE 2 HR RATED.

D1

B

NOTE: CELLAR TO BE FULLY WATERPROOFED

AIR AND VAPOR BARRIER

2" E.I.F.S.

B

OPEN CELLAR

CELLAR MAY NOT BE USED FOR LIVING OR SLEEPING ROOMS AND SHALL NOT BE RENTED SEPARATELY

APPROVED TYPE ANTTIDOWN DRAFT CAP

STORM COLLAR

2

D8

5'-0"

FURRING CLIP

1

METERS

F.A.I.

D2

B

4TH FLOOR

OPTIONAL 1" X 4" SHEET METAL GRAVEL STOP; 36" SQUARE MIN. SET IN FLASHING METAL FLASHING CEMENT

FD

D8

D2

1/4" GROUT 8" C.M.U.

EDGE OF SUMP STRIPPING FELTS STRIPPING FELTS METAL FLASHING STRAINER

D8

TYP. FIRE RETARD ALL CEILINGS W/ (2) LAYER 1/2" TYPE 'X' GYP. THROUGHOUT U.L. DESIGN NO. U419 MEA573-06-M

4" CONCRETE SLAB ON CORRUGATED STEEL DECK ON TOP OF STEEL JOISTS AS INDICATED ON STRUCTURAL PLANS

HANGERS AT 4'-0" O.C. MAX.

1

B

HALLWAY

B

N

DOUBLE SEAL TO WINDOW TO ALLOW DEFLECTION

1 1/2" C.R. CHANNELS AT 4'-0" O.C. MAX.

ING . AC SP G CH X. IN MA RR C. FU " O. L. 24 R MT FO

F.A.I.

WH

A-300

D8 B

KEYPLAN

AT KITCHEN & BATHROOMS WITHIN APARTMENTS

DOUBLE SEAL TO WINDOW

3

1

METERS

D

W

STAINLESS STEEL OR ZCC THROUGH-WALL FLASHING

AT KITCHEN CABINETS USE 3-5/8" METAL STUDS @ 12" O.C.

PUBLIC HALLWAYS BETWEEN APARTMENTS

W

STREET

U419

UL DESIGN:

B

B FD

D10 7/8" FURRING CHANNELS PERPENDICULAR TO F.J. @ 16" O.C.

VARIES

44 AT BATHS. & PWD. RMS. : USE 1 LAYER 5/8" W.R. GYP BD. WITH CERAMIC TILE INSTALL CEMENT BD. INSTEAD OF GYP. BD. AT TUB LOCATION. WATERPROOFING MEMBRANE TURN UP 4" ABOVE FIN. FLR.

MUNICIPALCONSULTANT:

SPENCER

STC:

9'-6"

28'-10"

UL DESIGN:

NOTES:

6"

VACANT LOT

FLOOR SYSTEM

6".

SEE PLAN

4

UP

DATE

CONTINUOUS ACOUSTIC CAULKING AT ALL JOINTS BOTH SIDES

BASE & FINISH FLOOR AS SCHEDULED

BASE

FLOOR SYSTEM

REVISIONS DESCRIPTION

24'-7"

3'-0"

BASE & FINISH FLOOR AS SCHEDULED

BASE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

FIRE BLOCKING TYP.

2 1/2" GALV. STUD TRACK ON FLOOR

4".

CLASS "A" ROOF FIRESTONE 180 OR APPROVED EQUAL TORCHED DOWN RUBBER ROOF LOOSE-LAID OVER POLYSOCYANURATE INSULATION, OR OTHER MANUFACTURER ACCEPTABLE INSULATION TYPE SPLICE WITH HIGH STRENGTH SEAM TYPE AS APPROVED MEA# 408-89-M (APP)

6'-0"

6"

2'-11 1/2"

CONTINUOUS ACOUSTIC CAULKING AT ALL JOINTS BOTH SIDES

FLOOR SYSTEM

ROOF

PLAN

2 LAYERS 5/8" GYP. BD. FIRECODE "C" CORE EACH SIDE 3 5/8" GALV. STUD TRACK ON FLOOR

BASE & FINISH FLOOR AS SCHEDULED

BASE

8" C.M.U.

8'-7 1/2"

3'-10"

PLAN 1 LAYERS 5/8" GYP. BD. EACH SIDE 2 1/2" GALV. STUD TRACK ON FLOOR

2 1/2" METAL STUDS @ 16" O.C.

6"

14'-6 1/2"

PLAN

3 5/8" METAL STUDS 20 GA. @ 16" O.C.

5'-6 1/2"

3'-6"

2 1/2" METAL STUDS @ 16" O.C.

1 A-300 51'-9"

1'-0"

19'-3 1/8"

CEILING AS SCHEDULED

SHEATHING

RELIEVING ANGLE

TAPE & JOINT COMPOUND BOTH SIDES

FLOOR /ROOF SYSTEM

19'-3 1/8"

2" THERMAFIBER SOUND ATTENUATION BLANKET

CEILING AS SCHEDULED

HEAD

TAPE & JOINT COMPOUND BOTH SIDES

FLOOR /ROOF SYSTEM

D5

HEAD

5'-1"

TAPE & JOINT COMPOUND BOTH SIDES

1 A-202.00

DESIGN & ARCHITECTURE

D5

FLOOR /ROOF SYSTEM

METAL PARAPET COPING

STRUCTURALENGINEER:

26'-10 1/4"

HEAD

5

CONTINUOUS ACOUSTIC CAULKING AT ALL JOINTS BOTH SIDES

CONTINUOUS ACOUSTIC CAULKING AT ALL JOINTS BOTH SIDES

SCALE: 1/4" = 1'-0"

28'-10"

CONTINUOUS ACOUSTIC CAULKING AT ALL JOINTS BOTH SIDES

CONC. STAIRS

6'-0"

ADJACENT 3 STORY FRAME RESIDENCE

1ST FLOOR PLAN

3

A

B

N

8"

C

DIEGO AGUILERA ARCHITECTS, P.C.

PARTITION

D

KEYPLAN

A-202.00

1 HOUR RATED WALL AT KITTES. AS PER MDL TYP.

2 E

2

DATE

CL 6"

1'-4"

A

B

W5

D7

SHEET 9 OF 18

E

5'-11"

A

REQ. LIGHT= 9.4 S.F. PROVIDED LIGHT= 42.2 S.F. REQ. AIR= 4.7 S.F. PROVIDED AIR= 42.2 S.F.

C MV

MV C

6'-3 5/8"

BEDROOM 93 SF

KITTE. 56 SF

1'-1 3/4"

9'-0 1/2"

4'-7 1/2"

1'-0"

BATH

MV

12'-3 1/4"

4"

KITTE. 54 SF

C

D7

A-200.00

D4 12" SOFFIT D6

3'-1 1/8"

2

A

12" SOFFIT

REQ. LIGHT= 9.4 S.F. PROVIDED LIGHT= 42.2 S.F. REQ. AIR= 4.7 S.F. PROVIDED AIR= 42.2 S.F.

3'-0"

REVISIONS DESCRIPTION

5'-11"

3'-6" HIGH METAL RAILING 9'-4"

2

2 A-202.00

D4

W5

REQ. LIGHT= 15.2 S.F. PROVIDED LIGHT= 42.2 S.F. REQ. AIR= 7.6= S.F. PROVIDED AIR= 42.2 S.F.

1'-11"

DRAWING TITLE: ELEVATIONS

28'-11 1/8"

8'-3 1/4"

CELLAR 31.89' 28'-11 1/8"

18'-7"

A

BEDROOM 91 SF

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DINING / LIVING 150 SF

SD CMD

DN

A

4

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

DN SD CMD

4"

A-202.00

R-2

8'-5 1/4"

2

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

R-2

1 BEDROOM

429 S.F.

NO.

6"

42" MTL RAILING TYP.

643 S.F.

UNIT 1A B

5'-6"

W5

REQ. LIGHT= 11 S.F. PROVIDED LIGHT= 62.7 S.F. REQ. AIR= 5.5 S.F. PROVIDED AIR= 62.7 S.F.

2 BEDROOM

6'-3"

MAILBOX

B

DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

CONC.

STREET

.

1'-4" D11

VEST.

SPENCER

IN

9'-2"

REAR YARD

DESIGNCONSULTANT: W1

1ST FLOOR BASE PLANE CALCULATION: (41.92'+41.86') / 2 = 41.89'

SCALE: 1/4" = 1'-0"

M 6" 1'-

4"

D9

D2

UNIT 1B

8'-3 1/4"

42" MTL RAILING TYP.

W5

SPENCER STREET ELEVATION

9'-0" D1

" 10 2'-

B

A

DINING / LIVING 172 SF

REF.

10'-0"

EXTERIOR LIGHTING

D11

2

A-300

CL

D4

4"

W7

10'-0"

10'-0"

8'-0"

10'-0"

EXTERIOR LIGHTING

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

2'-0"

2'-0"

STUCCO TYPE 2

STUCCO TYPE 2

W5

REQ. LIGHT= 17.5 S.F. PROVIDED LIGHT= 62.7 S.F. REQ. AIR= 8.75 S.F. PROVIDED AIR= 62.7 S.F.

BEDROOM 170 SF

PERFORATED METAL GRATE

MUNICIPALCONSULTANT:

9'-2"

W5

9'-11"

W1

28'-10"

D9

42" MTL RAILING TYP.

2ND FLOOR 51.89'

42" MTL RAILING TYP.

ø 5'-0"

1

D2

10'-0"

10'-0"

10'-0"

EXTERIOR LIGHTING

W5 STUCCO TYPE 1

STUCCO TYPE 1

W5

15'-5 1/2"

UP

STRUCTURALENGINEER:

8'-0"

W5

42" MTL RAILING TYP.

8'-1"

D9

8'-0"

10'-0"

EXTERIOR LIGHTING

6"

GRASS & PLANTERS

WINDOW WELL

3'-6" HIGH METAL RAILING

STUCCO TYPE 2

W1

3'-0"

8"

8'-5 1/4"

9'-7"

STUCCO TYPE 1

6" B

PROPERTY LINE

W5

9'-5 1/2"

3'-11 1/8"

W1

4"

D7

2'-0" EXTERIOR LIGHTING

D9

42" MTL RAILING TYP.

STUCCO TYPE 2

W5

2'-6"

CL

50'-0"

10'-0"

3RD FLOOR 61.89'

4"

CONC. STAIRS

STUCCO TYPE 2

W5

A

8'-4"

DN

W5

8'-5 1/4"

10'-0"

10'-0"

8'-0"

W1

4"

2'-0"

3

D9

42" MTL RAILING TYP.

10'-0"

10'-0"

W5

42" MTL RAILING TYP.

EXTERIOR LIGHTING

W5

PROPERTY LINE

1 A-202.00

3'-6 1/2"

L.L. WINDOW

OPEN TO BELOW

5

1'-1 3/4"

N

8'-0"

D9

W1

STUCCO TYPE 1

1

VACANT LOT

W1 KEYPLAN

6"

STUCCO TYPE 1

5'-0"

42" MTL RAILING TYP.

STUCCO TYPE 1

40'-0"

W5

10'-0"

8'-0"

10'-0"

A-300

1'-11"

2'-0"

STUCCO TYPE 2 EXTERIOR LIGHTING

10'-0"

1

DATE

2'-0"

3'-2".

42" MTL RAILING TYP.

5'-11"

4TH FLOOR 71.89'

BUILDING HEIGHT

W5

42" MTL RAILING TYP.

10'-0"

8'-1"

D9

MAX. BUILDING HEIGHT PER ZR 23-633 : 50'-0" ABOVE GRADE 40' BUILDING HEIGHT + 10' BULKHEAD ROOF ACCESS = 50'-0"

10'-0"

10'-0"

EXTERIOR LIGHTING W1

STUCCO TYPE 1

10'-0"

3'-6 1/2"

2'-10"

ROOF 81.89'

5'-11"

STUCCO TYPE 2

W5

1

31'-5"

2'-1 3/4"

3'-6 1/2"

4'-0"

5'-11"

STUCCO TYPE 2

4

REVISIONS DESCRIPTION

EQ 3'-10"

6'-0" 4'-0"

4'-0"

STUCCO TYPE 1

1'-11"

4'-0"

4'-0"

42" MTL RAILING TYP.

42" MTL RAILING TYP.

2'-0"

4'-0"

7'-11"

PARAPET WALL

3'-6 1/2"

52'-1"

16'-10"

2'-0"

5'-11"

10'-0"

3'-6 1/2"

BULKEAD ROOF ACCESS

5'-11"

6'-0"

NO. 2'-0"

A

B

EQ

DIEGO AGUILERA ARCHITECTS P.C. 97-40 62nd Drive. Suite 4L Rego park NY 11374 (718) 606 6008 - (718) 896 9432 dbaguilera@aol.com

14'-0" 14'-0"

C

3'-0" 1 1/4"

A-202.00

14'-10"

D

1'-7 3/4"3"

2

E DESIGN & ARCHITECTURE

DIEGO AGUILERA ARCHITECTS, P.C.

B

1'-1 3/4"

5

C

REF.

D

DIEGO AGUILERA ARCHITECTS, P.C.

E

N

9. DESIGN PROFESSIONAL STATES THAT TO THE BEST OF HIS KNOWLEDGE AND PROFESSIONAL JUDGEMENT THE DESIGN HAS BEEN MADE IN CONFORMANCE WITH THE ENERGY CODE. 10. ALL STEEL FRAMED WALLS COMPLY WITH TABLE 502.2.4.16(1) 16" O.C. STEEL FRAMED WALL EQUIVALENT R-VALUES

ENERGY ANALYSIS- CLIMATE ZONE 4- CHAPTER 5 ECCCNYS 2012 PROPOSED DESIGN VALUE CODE PRESCRIPTIVE VALUE

ITEM DESCRIPTION P TAC UNIT GAS HOT WATER HEATER ROOF CELLAR WALLS EXTERIOR WALLS EXTRIOR STUCCO WALLS EXERIOR FENESTRATION INTERIOR LIGHTING EXTERIOR LIGHTING PIPING SLAB ON GRADE

13 Seasonal Energy Eĸciency ZĂƟo (SEER) 13 Seasonal Energy Eĸciency ZĂƟo (SEER) R-38 R-11 R-20 R-27.8 U-0.34 26W CFL (COMPACT FLUORESCENT) - ECCCNY 2010 COMPLIANT 100W HID - HPS (HIGH PRESSURE SODIUM VAPOR LAMP) - ECCCNY 2010 COMPLIANT @ 80 lm/W R-2 R-11

13 SEER (TABLE 503.2.3(1)) 13 SEER (TABLE 503.2.3(1)) MINIMUM R-38 (TABLE 402.1.1) MINIMUM R-10 (TABLE 402.1.1 C) MINIMUM R-19 (TABLE 402.1.1) MINIMUM R-19 (TABLE 402.1.1) MAX. U-VALUE = 0.35 (TABLE 402.1.1) 50% OF LAMPS IN PERMANENTLY INSTALLED FIXTURES MUST BE HIGH EFFICACY TYPE MIN. REQ. 45 lm/W MINIMUM R-2 (SEC 403.3) MINIMUM R-10 (TABLE 402.1.1)

SUPPORTING DOCUMENTS EN-101.00 P-100.00 & EN-101.00 A-202.00 TO A-300.00 A-100.00 & A-300.00 A-100.00 TO A-101.00 & A-202.00 A-100.00 TO A-101.00 & A-202.00 EN-100.00 & EN-101.00 EN-100.00 EN-100.00 EN-100.00 A-202.00

NOTE: TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH NEW YORK CITY ENERGY CONSTRUCTION CODE 2011 (NYCECC 2011)

STRUCTURALENGINEER:

3 MECHANICAL SYSTEM PIPING (CAPABLE OF CARRYING FLUIDS ABOVE 105°F (41°C) OR BELOW 55°F (13°C)

MUNICIPALCONSULTANT:

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710 MINIMUM REQUIRED INSULATION: R-2

DESIGNCONSULTANT:

2

1

SAMUELWIEDER+ASSOCIATES 146SPENCERSTREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

PIPING INSULATION DETAIL SCALE: 12" = 1'-0"

LOCATION: 221 SPENCER STREET BROOKLYN, NY 11205

PROJECT: NEW 4 STORY RESIDENTIAL BUILDING

DRAWING TITLE: ENERGY ANALYSIS

SEALANDSIGNATURE

1

DATE: 8/11/2013 8:38:36 PROJECT NO.: PM 221-SPEN DRAWINGBY: HV DRAWING No.:

EN-100.00 SHEET 16 OF 18

E

D

C

B

A

page | 8


KEYPLAN

SITE INFORMATION

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075

QUALITY HOUSING REGULATIONS MAX. ALLOWED OR MIN. REQ'D DESCRIPTION

SECTION

65'-8 1/2"

100.00'

BALCON Y

EL: + 12.28' NEW TREE PER ZR 26.41

BALCON Y

(ZR 33-42(d)) PERMITTED OBSTRUCTION PERMITTED OBSTRUCTION WITHIN A REQUIRED SETBACK: ELEVATOR OR STAIR BULKHEADS. NEW TREE PER ZR 26.41

6'-7"

AVEN

6'-7"

T.C: EL: + 11.21'

HARRISON U E (70'-0" WIDE)

25'-0"

T.C: EL: + 10.91'

BALCON Y NEW TREE PER ZR 26.41

#16 BARTLETT STREET NEW 6 STORY & CELLAR BUILDING 10 CLASS A DWELLING UNITS CONST. CLASS: II-A OCCUPANCY CLASS: R-2 USE GROUP: 2

6 STORY

B.C: EL: 12'-6"+ 10.91'

NEW TREE PER ZR 26.41

50.00'

5 STORY

BALCONY

LOT:

ENGINEER:

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075 ENGINEER:

DESIGNCONSULTANT:

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

EL: + 12.00'

NEW TREE PER ZR 26.41

NEW TREE PER ZR 26.41

MUNICIPALCONSULTANT:

CONCRETE SIDEWALK

PROPOSED

MIN. DWELLING UNIT SIZE 400 S.F. WINDOWS DOUBLE GLAZED REFUSE STORAGE & DISPOSAL ENCLOSED REFUSE AREA TO BE PROVIDED AT A RATE OF 2.9 C.F. PER D.U., A MIN. OF 12 S.F.(MIN. DIM. 3 FT.) . LAUNDRY FACILITIES 1 PER 20 DWELLING UNITS DAYLIGHT IN CORRIDORS 50% OF CORRIDOR CAN BE EXCLUDED IF DAYLIGHT IN CORRIDOR IS PROVIDED & MEETS REQ. RECREATION SPACE 9 D.U. & 3.3% OF FLOOR AREA CAN BE EXCLUDED OVER FROM F.A PLANTING AREAS AREA BETWEEN THE STREET LINE AND THE STREET WALL SHALL BE PLANTED. DENSITY PER CORRIDOR 50% OF CORRIDOR AREA CAN BE EXCLUDED FROM F.A. IF LESS THAN 11 D.U.'S ARE SERVED BY THE CORRIDOR PER STORY.

ZR 28-24 ZR 28-25

ZR 28-32 ZR 28-33 ZR 28-41

DESIGNCONSULTANT:

T.C: EL: + 10.78'

T.C: EL: + 11.50'

COMPLIES COMPLIES PROVIDED

B.C: EL: + 11.09' 12'-6"

25'-0"

25'-0"

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

B.C: EL: + 10.40'

25'-0"

BARTLETT STREET

PROVIDED COMPLIES

(70'-0" WIDE)

PROVIDED AT 6TH FLOOR

3

REVISIONS DESCRIPTION

NO.

SCALE: 1/8" = 1'-0"

COMPLIES COMPLIES

HEIGHT & SETBACK DIAGRAMS

DORMER PERMITTED OBSTRUCTION 15'-0" SETBACK

PL

PL

ROOF +85.64'

SHEETTITLE:

ZONING ANALYSIS 6TH FLOOR +74.14'

REVISIONS DESCRIPTION

NEW SIX STORY RESIDENTIAL BUILDING LOCATION:

16 BARTLETT STREET, BROOKLYN NY 11206 62'-0"

73'-6"

MAX. BASE HEIGHT

PROJECTTITLE:

80'-0" MAX. BUILDING HEIGHT

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

65'-0"

RELIABLE EXPEDITING

73'-6" PROPOSED BUILDING HEIGHT

SITE LOCATION

MUNICIPALCONSULTANT:

NO.

DEPARTMENTOFBUILDINGSAPPLICATION#:

# 320716800 DOBBSCANSTICKER

DATE

GRADE +12.14'

4

SCALE: 12" = 1'-0"

1

ZONING MAP 13B

SCALE:

DATE:

2

SCALE: 1/16" = 1'-0"

DRAWNBY:

As indicated

12.0' + 12.28' / 2 = 12.14'

BARTLETT STREET

HARRISON AVENUE

6/20/2013 10:05:12 PM

CHECKEDBY:

HV AD

DRAWINGNO.

SCALE: 1/16" = 1'-0"

Z-100.00

SCALE: 12" = 1'-0"

SHEET 2

ABBREVIATIONS

DATE

SITE PLAN

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

SITE MAP

LEGEND

22732

SEAL:

RELIABLE EXPEDITING ZR 28-21 ZR 28-22 ZR 28-23

BASE PLANE CALCULATION:

1

2272

BLOCK:

ARCHITECT:

CONCRETE SIDEWALK

30'-0" MIN.

50'-0"

30'-0" MIN.

15'-0"

6 STOR Y

COURTYARD

62'-0" PROPOSED BASE HEIGHT

DRAWING LIST SHEET NAME CELLAR PLAN 1ST FLOOR PLAN TYP. FLOOR PLAN (2ND - 5TH) 6TH FLOOR PLAN ROOF PLAN ELEVATIONS ELEVATIONS ELEVATIONS ELEVATION / SECTION SECTIONS SECTIONS SECTIONS PARTITION DETAILS DOOR & WINDOW SCHEDULES, & LEGEND DETAILS ADA ENERGY ANALYSIS CONSTRUCTION EQUIPMENT PLAN, DETAIL & NOTES GENERAL NOTES PLUMBING RISER DIAGRAM GAS RISER DIAGRAM STREET TREE DRAWING STREET TREE DETAILS TITLESHEET ZONING ANALYSIS SURVEY & BORING TESTS DEDUCTIONS CODE ANALYSIS ZD1

STREET TREE PLANTING

ZR 25-811,36-711 BICYCLE PARKING

INNER COURT

BALCONY

15'-0" 60''-6" 72'-0" ( 10 X .3 = 3 ) LESS THAN 15 WAIVED (ZR 25-261) STREET FRONTAGE:150'-0" / ONE STREET TREE SHALL BE PROVIDED FOR EVERY 25 FEET OF STREET FRONTAGE 25'-0" =6 TREES OF THE ZONING LOT. 1 PER 2 DWELLING UNITS WAIVED (a) BUILDINGS OR BUILDING SEGMENTS CONTAINING 10 DWELLING UNITS OR LESS

SEAL:

ARCHITECT:

SHEET NUMBER

22732

5 STORY

10 DWELLING UNITS N/A CORNER LOT 0'-0" ALIGNED

EL: + 12.00'

15'-0" SETBACK 30'-0"

B.C: EL: + 10.65' 12'-6"

LOT:

2272

17,189 SF 76% (3,782 SF)

15'-0"

40'-0" MIN.

ZR 23-851 INNER COURT THE AREA OF AN INNER COURT SHALL NOT BE LESS THAN 1,200 SQUARE FEET, AND THE MINIMUM DIMENSION OF SUCH INNER COURT SHALL NOT BE LESS THAN 30 FEET

20'-0"

ZR 25-241, ZR 36-341 ZR 26-41, 33-03

BLOCK:

USE GROUP:2

30'-0"

20'-0"

ZR 23-462 ZR 23-541 ZR 23-633

95.17'

8.7 8'

USES PERMITTED AS-OF-RIGHT USE GROUPS: (RESIDENTIAL)1-4 MAX. FLOOR AREA RATIO 3,45 ( BASE F.A.R. , INCLUSIONARY HOUSING AREA) MAX. FLOOR AREA 17,189 SF = (4982.3 X 3.45 ) MAX. LOT COVERAGE 80% (4982.3 X .8 = 3,985 SF) DWELLING UNIT FACTOR 680 MAX. # DWELLING UNITS 25 DWELLING UNITS (17,189 / 680) MIN. SIDE YARD N/A MIN. REAR YARD N/A CORNER LOT FRONT YARD / STREET WALL N/A / STREET WALL TO ALIGN WITH LOCATION ADJACENT BUILDING REQUIRED SETBACK 15'-0" NARROW STREET 65'-0" BASE HEIGHT MAX. BUILDING HEIGHT 80'-0" MIN. PARKING SPACES 30% OF DWELLING UNITS

ZR 23-145 ZR 23-22

BROOKLYN NY 1120 6 PROPOSED 6 STORY RESIDENTIAL BUILDING

PROPOSED

3 STORY BRICK 1ST FL. EL. +12.21'

LOT AREA 4982 SF

18'-0"

DESCRIPTION

ZONING ANALYSIS MAX. ALLOWED OR MIN. REQ'D

42.67'

16 B A R T L E T T S T R E E T

4 STORY BRICK

2" BUILDING SEPARATION

13B 4,982.3 SF

SECTION ZR 22-00 ZR 23-952

EXISTING FIRE HYDRANT 1 STORY BRICK

1 STORY BRICK & BLOCK 1ST FL. EL. +12.97'

KEYPLAN

A-100.00 A-101.00 A-102.00 A-103.00 A-104.00 A-200.00 A-201.00 A-202.00 A-203.00 A-204.00 A-205.00 A-206.00 A-301.00 A-302-00 A-303.00 A-304.00 EN-100.00 EQ-100.00 G-100.00 P-100.00 P-101.00 ST-001 ST-002 T-100.00 Z-100.00 Z-101.00 Z-102.00 Z-103.00 Z-ZD1 Grand total: 29

16 BARTLETT STREET, BROOKLYN NY 11206 2272 3 R7A C2-4

1'-10" MAX. AS PER BC 3202

ADDRESS BLOCK LOT ZONING DISTRICT ZONING MAP LOT AREA

OF 25

SHEETTITLE:

TITLESHEET

1i

WINDOW SYMBOL

101

REVISION INDICATOR

1 Name Elevation

FLOOR ELEVATION SYMBOL

DOOR NUMBER

WALL / PARTITION TYPE

1i

1 A101

SIM

DETAIL REFERENCE SYMBOL

INSULATION RIGID PLYWOOD

ROOM TAG

WALL SECTION/DETAIL

CAST-IN-PLACE CONCRETE

SIM

Room name 1 A101

STEEL BATT INSULATION

ALUMINUM

150 SF FINISH WOOD

0

COLUMN LINE / GRID INDICATOR

SPOT ELEVATION SYMBOL

BD. BLDG. BLKG. BRKT. BRZ. C

BOARD BUILDING BLOCKING BRACKET BRONZE

CAB. CLKG.

CABINET CALKING CENTER LINE CEILING CLOSET CLEAR OPENING COLUMN CONCRETE CONNECT(ION) CONSTRUCTION CONTINUOUS CORRIDOR CERAMIC TILE CENTER COLD WATER

CLG. CLOS. CLR. OPG. COL. CONC. CONN. CONST. CONT. CORR. C.T. CTR. C.W.

E (E.) ELEC. EL. ENGR. EQ. EQUIP. EXH. E, EXIST. EXT. ELECT.

EAST ELECTRIC ELEVATION ENGINEER EQUAL EQUIPMENT EXHAUST EXISTING EXTERIOR ELECTRICAL

GA. GEN. GL. GYP. BD.

GAUGE GENERAL GLASS OR GLAZED GYPSUM BOARD

H HDWR. HDWD. HGT. H.M. HORIZ. H.W.

HARDWARE HARDWOOD HEIGHT HOLLOW METAL HORIZONTAL HOT WATER

MAINT. MAX. MECH. MTL. MEZZ. MFR. M.O. MIN. MTD. MUL. M.R. N

JANITOR

ANGLE LAMINATE POUND LEFT HAND

S

O.A. O.C. O.D. O.H. OPNG. OPP. ORIG. P

OVERALL ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING OPPOSITE ORIGINAL

P.LAM. PLAS. PLY. PNL. PR. PREFAB. PTN. PTD. Q

PLASTIC LAMINATE PLASTER PLYWOOD PANEL PAIR PREFABRICATED PARTITION PAINTED

MAINTENANCE QUAN. MAXIMUM MECHANICAL R METAL MEZZANINE REL. MANUFACTURER R. MASONRY OPENING R/A MINIMUM RAD. MOUNTED RECEP. MULLION REF. MOISTURE RESISTANT REFL. REINF. REQD. (N) NORTH R.H. N. NEW RM. N.I.C. NOT IN CONTRACT RND. NO.(OR #) NUMBER R.O. N.T.S. NOT TO SCALE REV.

QUANTITY RELOCATE REMOVE RETURN AIR RADIUS RECEPTACLE REFERENCE REFLECTED REINFORCED REQUIRED RIGHT HAND ROOM ROUND ROUGH OPENING REVISION

(S) S.C. SCHED. SECT. SHT. SIM. SQ. SF S.S. STD. STRUCT. SUSP. SYMM. SYS.

V SOUTH SOLID CORE SCHEDULE SECTION SHEET SIMILAR SQUARE SQUARE FEET STAINLESS STEEL STANDARD STRUCTURAL SUSPEND(ED) SYMMETRICAL SYSTEM

T T&B TECH. TEL. TEMPD. TEMP. GL. THK. TYP. T.B.D. T.B.S.

VERT. VEST. V.I.F. VOL.

VERTICAL VESTIBULE VERIFY IN FIELD VOLUME

NEW SIX STORY RESIDENTIAL BUILDING

W (W) W/ W.C. WD W.H. W/O WT.

WEST WITH WALL COVERING WOOD WATER HEATER WITHOUT WEIGHT

Y TOP AND BOTTOM TECHNICAL TELEPHONE TEMPERED TEMPERED GLASS THICK(NESS) TYPICAL TO BE DETERMINED TO BE SELECTED

PROJECTTITLE:

YD.

14'-11"

LOCATION:

100'-0"

# 320716800

MISCELLANEOUS ROUND

DOBBSCANSTICKER

SQ.FT. SQUARE

DRAWNBY:

As indicated UNDERWRITERS LABORATORY UTILITY UNLESS OTHERWISE NOTED

95.17'

MECH. DEDUCTION 281 SF

DEPARTMENTOFBUILDINGSAPPLICATION#:

U U.L.

4.83'

YARD

SCALE:

UTIL. U.O.N.

KEYPLAN

15'-1"

16 BARTLETT STREET, BROOKLYN NY 11206

DATE:

6/20/2013 10:04:49 PM

CHECKEDBY:

HV AD

BLOCK:

14'-11"

DRAWINGNO.

T-100.00

GYPSUM BOARD

SHEET 1

LOT AREA 4982 SF

50'-0"

GLASS BLOCK HARD WIRED SMOKE & CARBONMONOXIDE DETECTOR SHALL COMPLY TO NYC REG.

SD CMD

F.F. FIN. FLR. FLUOR. F.O.W. FPSC FR. FT. F.T. FURR. G

O INSIDE DIAMETER INCLUDE(D)(ING) INFORMATION INCANDESCENT

7.33'

CONCRETE MASONRY UNITS

F.ALM. FABR. F.E. F.E.C.

I I.D. FIRE ALARM INCL. FABRICATE FIRE EXTINGUISHER INFO. FIRE EXTINGUISHER INCAN. CABINET J FINISH FLOOR FINISH(ED) JAN. FLOOR L FLUORESCENT FACE OF WALL FIRE PROOF SELF- LAM. CLOSING LB. (OR #) FRAME L.H. FOOT OR FEET FIRE-TREATED FURRING M

42.67'

BRICK

F DOUBLE DEPARTMENT DETAIL DIAMETER DIMENSION DIVISION DOWN DOOR DRAWING DRAWER

50'-0"

MECH. VENT

MV

DBL. DEPT. DET. DIA. DIM. DIV. DN. DR. DWG. DRW.

AVENUE

PROPOSED 2 HOUR WALL

AIR CONDITIONING ACOUSTICAL ADJUSTABLE ALUMINUM ALTERNATE ANODIZED APPROVED APPROXIMATE ARCHITECT(URAL) AVERAGE ABOVE FINISH FLOOR

HARRISON

NORTH ARROW

PROPOSED 1 HR PARTITIONS

D

A A/C ACOUS. ADJ. ALUM. ALT. ANOD. APPD. APPROX. ARCH. AVG. A.F.F. B

18'-8"

EARTH

DAYLIGHT & DENSITY DEDUCTION 254 SF

OF 25 RECREATION ROOM DEDUCTION 565 SF

LOT:

2272

22732

SEAL:

ARCHITECT: 100'-0"

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075

LOT AREA DIAGRAM

3

SCALE: 1/16" = 1'-0"

ENGINEER:

6'-9 1/2"

100'-0"

16 Bartlett Street, Brooklyn NY

STAIR BULKHEAD 114 SF

30'-0"

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

30'-0"

LOT AREA 4982 SF

BARTLETT STREET

MUNICIPALCONSULTANT: 50'-0"

SCALE: 3/16" = 1'-0" 42'-8"

1

16 Bartlett Street is a mid-scale multiple dwelling project. It is a proposal for a 6 story, 17,000+ S.F. building that houses 10 dwelling units. Each unit is over 1,500 S.F. Each, and compliant to quality housing regulations. This project takes particular advantage of density & mechanical deductions to increase the allowable floor area by more than 3,000 S.F.

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

20'-0"

6"

REVISIONS DESCRIPTION

NO.

DATE

NET FLOOR AREA 3,387 SF

MECH. DEDUCTION 8 SF

MECH. DEDUCTION 3 SF

HARRISON

50'-0"

8'-1 1/2"

10"

1"

11'-2"

3'-0"

2'-9"

30'-0 1/2"

6"

MECH. DEDUCTION 10 SF

AVENUE

MECH. DEDUCTION 28 SF

MECH. DEDUCTION 8 SF 3'-2"

16'-2"

100'-0"

MECH. DEDUCTION 2 SF MECH. DEDUCTION 2 SF

DAYLIGHT & DENSITY DEDUCTION 293 SF

3'-8"

Moreover, this project also uses new materials & technnologies such as perfortared cold formed steel joists; these allow the building to have minimal floor slab thickness while still using conventional load bearing wall spacing. Effectively decreasing the amount of space reserved for framing, as well as the overall building weight.

41'-6"

8"

DN

1"

UP

DN

3'-11"

MECH. DEDUCTION 18 SF

1"

3'-8"

MECH 8 SF

6"

12'-0"

UP

19'-11 1/2"

REFUSE 12 SF

3'-0"

MECH. DEDUCTION 2 SF

3'-2"

6"

MECH. DEDUCTION 2 SF

page | 9

30'-0"

25'-2"

100'-0"

6TH FLOOR DEDUCTIONS

30'-0"

For this project I was responsible for proposed work drafting. Parametric BIM modeling & management. BIM family & componed creating and maintenance, in addition to zoning calculations & floor area deductions; as well as zoning diagrams & detailing of proposed building construction elements.

40'-0"

DESIGNCONSULTANT: 4'-10"

7'-4"

Samuel Wieder + Associates & Anestis Demou, 2013

STAIR BULKHEAD 128 SF ELEV. BULKHEAD

MAX. BUILDING FA: 17,189 SF X 3.3% = 567 SF

12'-0 1/2"

2

TYP. DEDUCTIONS (1ST - 5TH FLOORS) SCALE: 3/16" = 1'-0"

100'-0"

BARTLETT STREET

4

BUILDING AREA DIAGRAM SCALE: 1/16" = 1'-0"

FLOOR AREA

DEDUCTIONS

FAR: 3.45 MAX F.A.: 17,189 SF 1ST FLOOR: 3,782 SF 2ND FLOOR: 3,782 SF 3RD FLOOR 3,782 SF 4TH FLOOR: 3,782 SF 5TH FLOOR: 3,782 SF 6TH FLOOR: 1,593 SF

SHEETTITLE:

DEDUCTIONS

1ST FLOOR DEDUCTION = 395 SF 2ND FLOOR DEDUCTION = 395 SF 3RD FLOOR DEDUCTION = 395 SF 4TH FLOOR DEDUCTION = 395 SF

PROJECTTITLE:

NEW SIX STORY RESIDENTIAL BUILDING LOCATION:

16 BARTLETT STREET, BROOKLYN NY 11206 DEPARTMENTOFBUILDINGSAPPLICATION#:

5TH FLOOR DEDUCTION = 395 SF 6TH FLOOR DEDUCTION = 1,339 SF TOTAL DEDUCTIONS

TOTAL 20,503 SF

# 320716800 DOBBSCANSTICKER

= 3,314 SF SCALE:

DRAWNBY:

As indicated

F.A. - DEDUCTIONS: 20,503 SF - 3,314 SF

DATE:

6/20/2013 10:05:21 PM

CHECKEDBY:

HV AD

DRAWINGNO.

Z-102.00

= 17,189 SF PROPOSED SHEET 4

OF 25


KEYPLAN

B

A

C

C

B

KEYPLAN

KEYPLAN

A

30'-0"

40'-0"

30'-0" 100'-0"

FLASHING AS REQ.

2

30'-0"

40'-0" A-203.00

1

GRADE +12.14'

11'-0"

4'-0"

6'-2"

4'-0"

8'-2"

30'-0" A-206.00

6'-6"

1

2

4'-0"

5'-1"

4'-0"

4'-0"

8'-4 1/2"

6"

3'-0"

CL

MV

B

D7 1 4"

4"

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

1

232 SF

MV

REQ. LIGHT=18 S.F. 179 SF PROVIDED LIGHT=50 S.F. REQ. AIR=9 S.F. PROVIDED AIR=50 S.F.

REQ. LIGHT=23.4 S.F. PROVIDED LIGHT=25 S.F. REQ. AIR=11.7 S.F. PROVIDED AIR=25 S.F.

1 A-204.00

C SHEETTITLE:

10'-3 1/2"

6'-0"

5'-6"

4'-0"

7'-8"

4'-0"

5'-7"

1ST FLOOR PLAN

3

PROJECTTITLE: 20'-0"

30'-0"

NEW SIX STORY RESIDENTIAL BUILDING

100'-0"

2

3

CHECKEDBY:

1

1ST FLOOR PLAN

DOBBSCANSTICKER

As indicated

UP

MIN.

DRAWNBY:

DATE:

CHECKEDBY:

6/20/2013 10:00:53 PM

# 320716800 DOBBSCANSTICKER

(70'-0" WIDE)

SCALE:

SW

2

DRAWNBY:

1/4" = 1'-0" DATE:

AD

DRAWINGNO.

A-203.00

16 BARTLETT STREET, BROOKLYN NY 11206 DEPARTMENTOFBUILDINGSAPPLICATION#:

BARTLETT STREET

SCALE:

AD

5

A-200.00

SCALE: 1/4" = 1'-0"

HV

4

SCALE: 1/4" = 1'-0"

CELLAR PLAN 3'-0"

3/16" = 1'-0" 6/20/2013 10:03:00 PM

1

1

# 320716800

HANDRAIL

CHECKEDBY:

6/20/2013 10:00:55 PM

SW AD

DRAWINGNO.

A-100.00

STAIR HANDRAIL DETAIL (TYP.)

DATE

20'-0"

12'-7 1/2"

KITCHEN

1

16'-0"

DINING

3'-3"

REVISIONS DESCRIPTION

NO. D4

20'-5 1/2" 2

12'-6"

2

4'-0"

3'-8"

EXIT

4"

DINING

LOCATION:

16 BARTLETT STREET, BROOKLYN NY 11206

5

RELIABLE EXPEDITING

A-203.00A-206.00 20'-0"

NEW SIX STORY RESIDENTIAL BUILDING

4

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

TOTAL TRAVEL DISTANCE 13' - 9" = 57'-1" < 200'-0" OK

1'-4"

2

DESIGNCONSULTANT:

MUNICIPALCONSULTANT:

15'-11" 30'-0"

AVEN UE 50'-0"

REQ. LIGHT=10.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=5.25 S.F. PROVIDED AIR=20 S.F.

HARRISON

4'-0"

9'-10"

6'-0"

4"

CL

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075 ENGINEER:

(70'-0" WIDE)

10'-10"

4'-0"

4"

6'-0"

30'-0"

D2

9'-10"

SD CMD

D2

1'-8"

22732

SEAL:

4'-6"

2'-0"

3'-9 1/2"

4'-7"

MECH

7'-0"

6'-7" ENTRY

11'-2"

1 A-203.00

A-206.00

8"

19' - 7"

105 SF

4" 6'-7"EXIT

8"

BEDROOM #3 4'-0"

3'-0" 3'-4" 4'-0" 3'-8" 9'-0"

9'-0"

3'-6"

4'-6"

D1

D3 D11

1 A-205.00

2 A-201.00

12'-2" SD CMD

11'-11 1/2"

20'-0"

EXIT

D16

3'-3"

6'-8"

4" D8

LOT:

2272

ø 5'-0"

UP

ELEVATOR 8"

5'-0"

4'-10" 8'-0" 2'-8"

8'-4" 8'-5 1/2" 3'-2"

EXIT

D7

1

D10

D16

ø 5'-0"

3'-0". 6"

EXIT SD CMD

SD CMD 1

1 3'-4"

2

DN

AS PER MDL 57 8"

EXIT

3'-2"

3'-2" DN

9'-10 1/2"

8'-4"

1

1

4" 1

4'-10"

3'-2 1/2"

2'-10" CL

1'-2"

1'-2"

1'-2"

7'-10" 4"

5'-8" 2'-0" 20'-0"

30'-0 1/2"

5'-0 1/2" 1'-2" 3'-9 1/2" 8"

6" 3'-0"

DN

SHEETTITLE: 4'-0"

5"

EXIT

3'-7"

MAILBOXES

UP

2

REQ. LIGHT=9.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=4.75 S.F. PROVIDED AIR=20 S.F.

1

100'-0"

14'-0" SLOPE 1:12

30'-0"

4'-0" 1

1

15' - 3"

EXIT

4'-0"

5'-0" 5'-0 1/2"

3'-1" 6"

BEDROOM

3'-0"

D15 7 R@ 7 3/4" UP

EXIT

LOBBY 13'-11"

93 SF

5'-0"

10'-4"

D3

UP 23' - 9"

D11

6'-0"

3'-0"

2'-0 1/2" 18" MIN.

2'-5 1/2"

EXIT

2 3'-10 1/2"

20'-0" 4"

3"

13' - 1"

4'-8"

3'-0"

6'-0"

D16

REFUSE MV 4"

1

20'-10"

PROJECTTITLE:

5'-0"

2'-0"

4'-0" 5'-0"

4" 10'-0" 4"

4"

D1 4'-8"

D7 1

3"

7 R@ 7 3/4"

CELLAR PLAN

5'-7"

30'-0"

3'-4"

5'-0"

5'-0"

3'-4" 4'-0" 6'-6"

20'-0" SLOPE 1:12

4" 9'-10"

D7 MDL33- KITCHEN WALL 1 HR. RATED (TYP.)

18' - 7"

3'-9 1/2"

2'-10 1/2"

2

1'-4 1/2" 8'-2"

1'-0"

1

DRAWINGNO.

4'-7 1/2" 1

4"

1

3'-0"

DEPARTMENTOFBUILDINGSAPPLICATION#:

DRAWNBY:

DATE:

5' - 7"

D9

1'-2"

EXIT

4'-0"

20'-0"

DOBBSCANSTICKER

SCALE: 3/16" = 1'-0"

6'-1"

ROOM:247 S.F. + 164 SF = 411 SF REQ. LIGHT=41.1 S.F. PROVIDED LIGHT=50 S.F. REQ. AIR=20.5 S.F. PROVIDED AIR=50 S.F.

1 A-204.00

1

BARTLETT STREET

SCALE:

SECTION / ELEVATION 2

3'-5"

10'-4"

D8

A-204.00

3

3

# 320716800

2

6'-0" x 8'-0"

12'-0 1/2"

DEPARTMENTOFBUILDINGSAPPLICATION#:

SCALE: 3/16" = 1'-0"

4'-0"

4" 3'-9"

DATE

D8 SD 4" CMD

REQ. LIGHT=10.4 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=5.2 S.F. PROVIDED AIR=20 S.F. 11'-4"

DN 3'-0"

A-206.00 D10

105 SF REQ. LIGHT=10.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=5.25 S.F. PROVIDED AIR=20 S.F.

2'-4"

D8

LOCATION:

16 BARTLETT STREET, BROOKLYN NY 11206 CELLAR +5.64'

13' - 4" TOTAL TRAVEL DISTANCE = 57'-4" < 200'-0" OK SD CMD

1

5'-4" D MV

11'-4"

102 SF

5'-6 1/2"

6"

LOCATION:

SECTION / ELEVATION 1

16'-0" D5

29'-8 1/2" < 30'-0" OK

4'-0"

5'-10"

WATER METER ROOM

38'-4"

NOTE: CELLAR TO BE FULLY WATERPROOFED

4'-0" ". 5'-0

8'-10"

W

1

D15

1

DINETTE

245 SF

C

A-203.00A-206.00

20'-0"

1

NEW SIX STORY RESIDENTIAL BUILDING

1'-2"

1'-2"

5'-0" 4"

50'-0" 42'-8"

REQ. LIGHT=16.4 S.F. REQ. AIR=8.2 S.F.

DINING

GAS METER ROOM

9'-10"

CL D2

4"

CL

3'-6 1/2"

6"

SD CMD

CL

D9

BEDROOM #2

4' - 4" 5'-0".

BEDROOM #4 1'-2"

5"

SD CMD 1 D8

1

103 SF

REQ. LIGHT=10.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=5.25 S.F. PROVIDED AIR=20 S.F.

1

19' - 5" 1

1 5'-8"

18 R@ 7 5/8"

5'-10"

12'-2"

REQ. LIGHT=16.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=8.25 S.F. PROVIDED AIR=20 S.F.

1 D7

AC

5'-8"

BLOCK:

ARCHITECT:

162 SF

MV

BATH

BEDROOM #3

1

15'-0"

M. BEDROOM #1

D2

1'-6"

6"

1

D8 4"

4"

WIC

D7

8'-8"

8'-2"

3'-4"

6'-10"

1 D7

UP SD CMD

A

1

4"

MV

1'-0"

8'-8" WATER PUMP AT ELEV. PIT

4'-0"

2 4'-6"

8'-10"

4'-6"

KITCHEN 163 SF

3'-6"

ELEVATION / SECTION PROJECTTITLE:

D3

7'-9 1/2" 10"

1

6

REQ. LIGHT=10.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=5.25 S.F. 9'-9" AIR=20 S.F. PROVIDED

7 R@ 7 3/4"

8"

1

1 MV

D10

1ST FLOOR +16.64'

4"

5'-0"

MAX.

D10

REVISIONS DESCRIPTION

104 SF

2'-5"

6"

7'-0"

3'-4"

SHEETTITLE:

11'-6"

RELIABLE EXPEDITING 777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

1'-0"

W4

B

1'-2"

3'-4"

1'-6" 1'-6"

8"

ELECTRIC METER ROOM

1'-0"

W4

MUNICIPALCONSULTANT:

NO.

UP

1'-0"

W4

1'-4 1/2"

11'-6"

W3

5'-0"

5'-0"

MAX.

7'-3"

3

A-201.00 1

20'-0"

18'-0"

6'-8"

A-205.00

D14

STAIR B

ELEVATOR

4"

8'-4 1/2"

8"

SLOPE 1:12

1

9'-9"

4"

4'-0"

12'-6"

M. BATH.

BEDROOM #2

1

AC

4"

D8

D MV 5'-6"

1

DESIGNCONSULTANT:

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

8" D14

SD CMD D2 W

9'-1 1/2"

3'-0".

5'-0"

COURT YARD

1 D1

D1

8"

CONCRETE FOUNDATION WALL (REFER TO STRUCTURAL)

A-204.00

SLOPE 1:12

14'-10"

SD CMD

CL

4'-1 1/2"

7'-0"

10'-10"

4'-10" 4"

32'-10 1/2" 9'-1 1/2"

1'-10"

1

EIFS

STORAGE

4"

5'-0".

4"

12'-0"

4'-0"

13'-4"

W4

8"

20'-0"

6" 19'-0"

11'-6"

W4

2ND FLOOR +28.14'

1

7'-4"

5'-0" 4'-0" 6'-0"

8"

D14

W4 D10

W4

4'-0" 4'-0" 4'-6"

SD CMD

FD

4'-0"

1

A-205.00

HARRISON UE

4'-0"

EXIT

D16

1'-0" 13'-11"

D16

AVEN

6'-0" 8"

6 R@ 7 3/4"

1

REQ. LIGHT=16.5 S.F. PROVIDED LIGHT=20 S.F. REQ. AIR=5.8 S.F. PROVIDED AIR=20 S.F.

19' - 10"

LAUNDRY 5'-0"

12'-6"

UP

UP

EXIT

4'-8"

DATE

D16

3'-6"

REVISIONS DESCRIPTION

SD CMD

10'-6"

EXIT D16

27'-8"

1

1

1

1'-0"

1'-4" 3'-8"

1'-4"

1'-4" UP

1'-4"

10'-0"

FD

6 R@ 7 3/4"

8"

2 A-206.00

8'-4"

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

W4

CONCRETE FOOTING (REFER TO STRUCTURAL)

D16

W4

6"

11'-6"

W4

40'-0"

1'-4"

1'-0"

SD CMD

3'-8"

73'-6"

MUNICIPALCONSULTANT:

1'-4"

6'-9 1/2"

26'-10"

3'-8"

1'-10"

4'-0"

50'-0"

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

46'-9 1/2"

W4

NO.

W7

D8

D7 4"

D8

BATH

50'-0"

CELLAR SHALL NOT BE USED FOR LIVING OR SLEEPING, AND WILL NOT BE RENTED SEPARATELY

A-205.00

W4

12'-6"

161 SF

MV

30'-0"

4'-0"

30'-0"

4'-11"

1,311 SF

1

4'-0"

DESIGNCONSULTANT:

4'-11"

EIFS

4'-0"

LINTELS REFER STRUCT.

D10

W7

8'-2"

1'-2" 8"

W4

1

WIC

ENGINEER:

OPEN CELLAR 1,169 SF

CELLAR SHALL NOT BE USED FOR LIVING OR SLEEPING, OPEN CELLAR AND WILL NOT BE RENTED SEPARATELY

ELEVATOR

11'-6"

4'-0"

1,311 SF

29'-10"

OPEN CELLAR

W4

28'-6"

W4

SHAFT

W4

RELIABLE EXPEDITING

W4

M. BEDROOM #1 1

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075

27'-4"

4'-11"

4'-11"

O F N EW

EIFS

W7

22732

SEAL:

M. BATH

K

OR

0 1 3563 Y

UNEXCAVATED

3RD FLOOR +39.64'

W7

1'-2"

2" 4'-0" 4'-0"

E

AN

R EG

I

11'-6" 11'-6"

A

TYP. FLOOR ASSEMBLY 3/4" HARWOOD FLOORING ON 3/4" PLYWOOD SUBSTRATE MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" TYP. X GYP. BD

W4

W7

LOT:

2272

MV

4TH FLOOR +51.14'

W7

CONCRETE FOUNDATION WALL (REFER TO STRUCTURAL)

E X C EL S IOR

TE

ENGINEER:

5TH FLOOR +62.64'

W4

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075

FLASHING AT ALL WINDOWS & DOOR S AS REQ.

FACE BRICK 1" AIR GAP ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BD.

ST

W4

W7

D ER E A RCH ST T I S D I E S M

EIFS

W7

8'-2 1/2"

BLOCK:

ARCHITECT:

D10

6TH FLOOR +74.14'

W7

22732

SEAL:

CT TE U O

D10

A

6 4'-2"

LOT:

2272

5'-0"

A-206.00

4'-0"

BLOCK:

1'-6"

ROOF +85.64'

30'-0"

3

A-206.00

A-203.00

1

3

A-203.00A-206.00

A-206.00

ARCHITECT:

W7

2

1

25'-2"

D2

EXTERIOR STUCCO WALL 2" EIFS RIGID INSULATION (R12.8) ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BOARD

1'-10"

9'-0"

FLASHIN G AS REQ.

1'-0"

EXTERIOR STUCCO WALL 2" EIFS RIGID INSULATION (R-12.8) ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BOARD

4'-10"

TYP. ROOF ASSEMBLY 3-PLY BITUMINOUS MEMBRANE ON 2" RIGID INSULATION 10" MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" GYP. BOARD

A-101.00

SCALE: 3/8" = 1'-0"

SHEET 15 OF 25

SHEET 7

KEYPLAN

OF 25

SHEET 8

KEYPLAN

OF 25

KEYPLAN

100'-0"

3

D16

D16

REFER TO WINDOW SCHEDULE FOR TYPES

FLASHING AS REQUIRED

6TH FLOOR +74.14'

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075

LAUNDRY

KITCHEN

11'-6"

M. BATH

W4

11'-6" W4

OPEN CELLAR

REVISIONS DESCRIPTION

NO.

LAUNDRY

KITCHEN

2

EXTERIOR STUCCO WALL 2" EIFS RIGID INSULATION (R-12.8) ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BOARD

M. BATH

LAUNDRY

KITCHEN

W4

W4

W4

DINING

11'-6"

11'-6" 11'-0"

GRADE +12.14'

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

D6

LOCATION:

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

4TH FLOOR +51.14'

MUNICIPALCONSULTANT:

RELIABLE EXPEDITING W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

D6

W4

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

D6

REVISIONS DESCRIPTION

NO.

3RD FLOOR +39.64'

DATE

REVISIONS DESCRIPTION

NO.

DATE

C

W4

W4

FACE BRICK

W4

W4

W4

W4

W4

W4

W4

FACE BRICK

W4

W4

W4

D6

LAUNDRY

KITCHEN

2ND FLOOR +28.14'

DINING

W7

W7

2ND FLOOR +28.14'

W4

W4 REFER TO DOOR SCHEDULE FOR TYPES

EXISITING 1 STORY BRICK BUILDNG

SHEETTITLE:

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

W4

REFER TO WINDOW SCHEDULE FOR TYPES

16 BARTLETT STREET, BROOKLYN NY 11206

SHEETTITLE:

SECTIONS

ELEVATIONS

1ST FLOOR +16.64'

D11

NEW SIX STORY RESIDENTIAL BUILDING

DESIGNCONSULTANT:

D6

FACE BRICK

PROJECTTITLE:

GRADE +12.14'

GRADE +12.14'

NEW SIX STORY RESIDENTIAL BUILDING W6

W6

W6

W6

STONE W6

W6

1ST FLOOR +16.64'

D3

STONE VENEER W6

W6

VENEER

16 BARTLETT STREET, BROOKLYN NY 11206 CELLAR +5.64'

# 320716800

NOTE: ALL STONE TRIM SHALL NOT PROJECT MORE THAN 4" FROM PROPERTY LINE. TYP.

DEPARTMENTOFBUILDINGSAPPLICATION#:

# 320716800

PROJECTTITLE:

NEW SIX STORY RESIDENTIAL BUILDING W6

W6

W6

W6

LOCATION:

OPEN CELLAR

CELLAR +5.64'

DEPARTMENTOFBUILDINGSAPPLICATION#:

CELLAR +5.64'

W4

STONE VENER

M. BATH

1ST FLOOR +16.64'

11'-0"

WATERPROOFING

W4

REFER TO WINDOW SCHEDULE FOR TYPES

WIC

SECTIONS

KITCHEN

D14

W4

STONE

TYP. FLOOR ASSEMBLY 3/4" HARWOOD FLOORING ON 3/4" PLYWOOD SUBSTRATE MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" TYP. X GYP. BD

A

WIC

22732

SEAL:

D6

B

PROJECTTITLE:

D14

W4

SCALE: 3/16" = 1'-0"

SHEETTITLE:

1ST FLOOR +16.64'

D14

W4

D6

11'-6"

DINING

W2

W4

5TH FLOOR +62.64'

W4

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

ENTRY DETAIL 1

D7

D3

W4 D6

DINING

2ND FLOOR +28.14'

D8

LOT:

2272

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075 ENGINEER:

W4

GRADE +12.14'

11'-6"

M. BATH

D8

DINING

6TH FLOOR +74.14'

W4

MUNICIPALCONSULTANT:

2ND FLOOR +28.14'

W1

FACE BRICK

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

DATE 11'-6"

1'-7 1/2"

DINING

D10

RELIABLE EXPEDITING

WIC

777 KENT AVE, BROOKLYN, NY 11205 (718) 797-2710

BLOCK:

ARCHITECT:

42" MTL RAILING (TYP.)

CELLAR +5.64'

3RD FLOOR +39.64'

W4

W4

D6

W4

D7 W4

BEDROOM #4

W4

ENGINEER:

LINTELS REFER STRUCT.

FLASHING AT ALL WINDOWS & DOOR S AS REQ.

DINING

W4

1ST FLOOR +16.64'

W2 D3

4TH FLOOR +51.14'

D13

3RD FLOOR +39.64'

D15

W4

DESIGNCONSULTANT:

RELIABLE EXPEDITING

11'-6"

W4

FACE BRICK

W4

DINING

MUNICIPALCONSULTANT:

73'-6"

4TH FLOOR +51.14'

W1

W2

FLASHING AT ALL WINDOWS & DOOR S AS REQ.

KITCHEN

146 SPENCER STREET SUITE #3006 BROOKLYN NY, 11205 T. 718.484.3201

11'-6"

SHAFT ELEVATOR

W4

W4

ANESTIS DEMOU RA ARCHITECT 1481 YORK AVENUE NEW YORK, NY 10075

DESIGNCONSULTANT:

LAUNDRY W4

W3

LOBBY

D15

5TH FLOOR +62.64' 5TH FLOOR +62.64'

W1

TYP. FLOOR ASSEMBLY 3/4" HARWOOD FLOORING ON 3/4" PLYWOOD SUBSTRATE MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" TYP. X GYP. BD

ROOF +85.64' EIFS

W4

REFER TO DOOR SCHEDULE FOR TYPES

6TH FLOOR +74.14'

ENGINEER:

WIC W4

REFER TO WINDOW SCHEDULE FOR TYPES

42" MTL RAILING (TYP.)

FACE BRICK

22732

SEAL:

ARCHITECT:

2ND FLOOR +28.14'

RECREATION ROOM

LOT:

2272

11'-6"

D12

TYP. ROOF ASSEMBLY 3-PLY BITUMINOUS MEMBRANE ON 2" RIGID INSULATION 10" MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" GYP. BOARD

W4

D10

A-206.00

BLOCK:

11'-6"

W4

TYP. ROOF ASSEMBLY 3-PLY BITUMINOUS MEMBRANE ON 2" RIGID INSULATION 10" MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" GYP. BOARD

4

TYP. FLOOR ASSEMBLY 3/4" HARWOOD FLOORING ON 3/4" PLYWOOD SUBSTRATE MTL. JOIST 7/8" FURRING CHANNELS & 1 LAYER 5/8" TYP. X GYP. BD

FACE BRICK 1" AIR GAP ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BD.

11'-6"

SEAL:

11'-6"

W4

11'-6"

W4

FACE BRICK 1" AIR GAP ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BD.

ROOF +85.64' REFER TO DOOR SCHEDULE FOR TYPES

22732 11'-6"

LOT:

2272

11'-6"

4'-2" 15'-8" W4

1 2

EXTERIOR STUCCO WALL 2" EIFS RIGID INSULATION (R-12.8) ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BOARD

BLOCK:

ARCHITECT:

W4

5

C

13'-1"

7'-10"

B

FLASHING AS REQUIRED

ROOF +85.64' REFER TO DOOR SCHEDULE FOR TYPES

4

30'-0"

A

EXTERIOR STUCCO WALL 2" EIFS RIGID INSULATION (R-12.8) ON 8" CMU WALL 3 1/2" MTL. STUDS & 1 LAYER 5/8" GYP. BOARD

3

11'-6"

20'-0"

2

11'-6"

20'-0"

1

5

11'-0"

30'-0"

4

13'-0"

2

11'-0"

1

NOTE: ALL STONE TRIM SHALL NOT PROJECT MORE THAN 4" FROM PROPERTY LINE. TYP.

GRADE +12.14'

LOCATION:

16 BARTLETT STREET, BROOKLYN NY 11206 DEPARTMENTOFBUILDINGSAPPLICATION#:

CELLAR +5.64'

# 320716800

WATERPROOFING

5'-6"

1 DOBBSCANSTICKER

SCALE:

1

BUILDING SECTION 1 SCALE: 3/16" = 1'-0"

NOTE: REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL DESIGN

DOBBSCANSTICKER

DRAWNBY:

3/16" = 1'-0" DATE:

6/20/2013 10:03:11 PM

CHECKEDBY:

NOTE: REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL DESIGN

SW

A-204.00 SHEET 16 OF 25

SCALE:

1

BUILDING SECTION 3 SCALE: 3/16" = 1'-0"

3

ENTRY DETAIL 2 SCALE: 3/16" = 1'-0"

DRAWNBY:

3/16" = 1'-0" DATE:

AD

DRAWINGNO.

A-206.00

6/20/2013 10:03:45 PM

CHECKEDBY:

SCALE:

HV AD

DRAWINGNO.

DOBBSCANSTICKER

DRAWNBY:

3/16" = 1'-0"

1

BARTLETT STREET ELEVATION

DATE:

6/20/2013 10:01:28

CHECKEDBY:

HV AD

SCALE: 3/16" = 1'-0"

DRAWINGNO.

A-206.00 SHEET 18 OF 25

A-200.00 SHEET 12 OF 25

page | 10


25 Arleigh Road, Queens NY Rapid Expediting Services, 2012

This project is a material & finishes study for an existing residence. The owner wanted to see a visualization of different materials & colors for flooring, walls, windows & doors. I was solely responsible for all 3D modeling of the existing property. Moreover, I was also in charge of visualization & rendering of the proposed work.

page | 11


page | 12


75-16 Rockaway Blvd, Brooklyn NY Coombs & Associates, Inc. , 2012

A feasibility study for the conversion of an existing pool hall into a beer garden & food service establishment. The exterior envelope was kept throughout to bring homage to the facilitieâ&#x20AC;&#x2122;s industrial past. On the inside, a large outdoor space was carved out of the exiting structure in order to provide an interior courtyard for patrons. The interior courtyard is open to the sky as well as to passerbys through openings on the exterior walls, which aim to peek the interest of pedestrians and drivers alike. I was solely responsible for the 3D modeling, space planning & deign features of the study.

page | 13


CPLDC Chinatown Gateway City University of New York, NYCCT, 2013

An educational experiment in urban planning & development, the CPLDC Chinatown Gateway aims to solve the economic & social issue of Manhattanâ&#x20AC;&#x2122;s Lower East Side gentrification. I was responsible for the 3D modeling of 12 acres of area within the Chinatown neighborhood district in NYC. I was also in charge of fabricating the physical site in order to provide students with a working thre dimensional platform.

page | 14


HECTOR VILLAGRAN

2259 64th Street, Brooklyn NY 11204 P: (718) 812-8048 e: hvillagran7@gmail.com

[EDUCATION] New York City College of Technology // City University of New York // Brooklyn, NY Bachelor of Architectural Technology GPA: 3.88, Honors Scholar, Summa Cum Laude Dean’s List: 2008 – 2012 Graduation: December, 2012 [WORK EXPERIENCE] SW+A // Designer / Draftsman / BIM Manager / Digital Artist // 2012 – Present Perform building code, zoning and energy code analysis, research & application to current & existing construction projects in the NYC metropolitan area, as well as throughout New York State. Survey of existing and as built conditions for code compliance & approval. Provide drafting services for a variety of architectural projects, including commercial, residential and mixed use developments. Generate three dimensional models and renderings. Perform BIM management and administration; including family and parameter generation and management, and parametric modeling and coordination. New York City College of Technology - CUNY // Professor’s Assistant / CLT // 2013 - Present Provide assistance with advanced 3D modeling instruction to 3rd and 4th year students, including presentation, rapid prototyping and visualization, as well as building code & zoning study for design assignments. Management & administration of online class blogging platforms as well as generation of resources for educational research & development for current NSF projects & grants. Tergram Engineering Services, P.C. // Junior Architect / Office Manager // 2005 – 2012 Performed energy analysis, zoning and building code research for small residential developments in the NYC metropolitan area. Developed a comprehensive system of construction documentation and detailing for engineering and architectural projects. Provided IT, technical support, and networking services. Oversaw the integration and development of new software such as AutoCAD 2010, Adobe Photoshop, Autodesk Revit Architecture and Microsoft Office; as well as DOB filing. [SKILL HIGHLIGHTS] Experience in NYCBC & Zoning resolution research & analysis 4+ Years of experience in Revit Architecture Adobe Photoshop, Illustrator & InDesign 3ds Max Design MS Office 1998 – 2013 Vray, iRay, Mental Ray & Scanline rendering Survey of existing & as built conditions [REFERENCES] Available upon request

page | 15

AutoCAD 3D Hand Drafting AutoCAD R12 to 2014 Rhino 3D w/ Grasshopper Google SketchUp Hand sketching Autodesk Impression


ARCH | | TECH

HECTOR VILL AGRAN

Hector villagran professional portfolio  