Page 76

7-8

EXHAUST SYSTEM

Measure the position sensor output voltage at fully open position. % Position sensor output voltage EXCV is fully open: 3.5 output voltage (+ Yellow – - B/Br)

4.5 V

If the measured voltage is more than specification, adjust the No.2 cable adjuster as follows: • Set the EXCVA to adjustment position. (!7-2) # Adjusting the No. 2 cable with the EXCV fully opened can damage the EXCVA. Be sure to adjust the No. 2 cable with the EXCV set in adjustment position. • Turn out the No. 2 cable adjuster 1. • Repeat the above procedure until the output voltage comes within the specified value. % Position sensor output voltage EXCV is fully open: 3.5 output voltage

4.5 V

• After adjusting the EXCV cables, perform 2nd step to confirm C46 is not indicated.

EXHAUST PIPE AND MUFFLER REMOVAL • Remove the right frame cover. (!9-5) • Remove the lower frame cover 1.

• Disconnect the EXCVA lead wire couplers 2.

V

Reparatie Manuel M1800R deel 2  
Reparatie Manuel M1800R deel 2  

Reparatie Manuel M1800R deel 2

Advertisement