EXHAUST SYSTEM

• To set the EXCV to fully close position, apply 12 volts to A and B terminals. Positive wire –– A (Pink wire) terminal Negative wire –– B (Gray wire) terminal # To prevent the motor damage, stop applying 12 V as soon as the EXCV reaches fully close position.

• Turn the ignition switch ON. • Measure the position sensor output voltage at fully close position. % Position sensor output voltage EXCV is fully close: 0.5 output voltage (+ Yellow – - B/Br)

12 V

V

1.5 V

" 09900-25008: Multi circuit tester set 09900-25009: Needle pointed probe set & Tester knob indication: Voltage (') If the measured voltage is less than specification, adjust the No.1 cable adjuster as follows: • Set the EXCVA to adjustment position. (!7-2) # Adjusting the No. 1 cable with the EXCV fully closed can damage the EXCVA. Be sure to adjust the No.1 cable with the EXCV set in adjustment position. • Turn out the No. 1 cable adjuster 3. • Repeat the above procedure until the output voltage becomes specified value. % Position sensor output voltage EXCV is fully close: 0.5 output voltage

1.5 V

• To next step. NOTE: If C46 code is indicated after adjusting the voltage, increase the voltage to 0.9 V. 4th step: To set the EXCV to fully open position, apply 12 volts to A and B terminals. Positive wire –– B (Gray wire) terminal Negative wire –– A (Pink wire) terminal # To prevent the motor damage, stop applying 12 V as soon as the EXCV reaches fully open position.

12 V

7-7