Step 3 1) Measure the starter relay voltage at the starter relay connectors (between Y/G + and B/Y -) when the starter button is pushed. Is a voltage OK? YES

NO

Go to Step 4. • Faulty engine stop switch • Faulty clutch switch • Faulty GP switch • Faulty turn signal/side-stand relay • Faulty starter button • Faulty ignition switch • Faulty side-stand switch • Poor contact of connector • Open circuit in wire harness

Step 4 1) Check the starter relay. (!10-18) Is the starter relay OK? YES NO

Poor contact of the starter relay Faulty starter relay

Starter motor runs but does not crank the engine Step 1 1) The starter motor runs when the transmission is in neutral, but does not run when the transmission is in any position other than neutral, with the side-stand up. 2) Check the side-stand switch. (!10-19) Is the side-stand switch OK? YES NO

Go to Step 2. Faulty side-stand switch

Step 2 1) Check the starter clutch. Is the starter clutch OK? YES NO

Faulty starter clutch • Open circuit in wire harness • Poor contact of connector