10-8

ELECTRICAL SYSTEM

CHARGING SYSTEM

Regulator/Rectifier

IG. switch

Generator

B

SCR

TROUBLESHOOTING Battery runs down quickly Step 1 1) Check accessories which use excessive amounts of electricity. Are accessories being installed? YES NO

Remove accessories. Go to Step 2.

Step 2 1) Check the battery for current leaks. (!10-9) Is the battery for current leaks OK? YES NO

Go to Step 3. • Short circuit of wire harness • Faulty electrical equipment

Step 3 1) Measure the regulated voltage between the battery terminals. (!10-10) Is the regulated voltage OK? YES NO

• Faulty battery • Abnormal driving condition Go to Step 4.

Step 4 1) Measure the resistance of the generator coil. (!10-10) Is the resistance of generator coil OK? YES NO

Go to Step 5. • Faulty generator coil • Disconnected lead wires

Load

B

Battery

IC

B