FI SYSTEM DIAGNOSIS

Is the voltage OK?

YES

NO

• Pink wire open or shorted to ground • If wire and connection are OK, intermittent trouble or faulty ECM. • Recheck each terminal and wire harness for open circuit and poor connection. • Replace the ECM with a known good one, and inspect it again. • Pink or B/W wire open, or Pink wire shorted to ground • Loose or poor contacts on the ECM coupler (terminal M or X) • If wire and connection are OK, replace the GP switch with a new one.

10)After repairing the trouble, clear the DTC using SDS tool. (#5-26)

1 ECM coupler (Harness side) (Black) (Gray)

5-67