Issuu on Google+

Product Overview

high precision thermoregulation


Product Overview

Wow! l ... u f r e w o p nd a l l a m s o S

NEW!

Grande Fleur

®

New model: Low cost entry to the Unistat® technology – with all the benefits! The new Grande Fleur expands the product offering in the dynamic temperature control range. The Grande Fleur together with the Petite Fleur are two small Tangos and are the entry level into the world of Unistat technology. The compact dimensions and unique thermodynamics of the Grande Fleur mean it is ideally suited for high precision temperature control of research reactors. The Grande Fleur offers all of the great performance and features of the Unistat series, achieving unrivalled heating and cooling rates.

Modern technology, easy operation – the new Grande Fleur®

2

www.huber-usa.com


Content Controller & Functions ............................................................... 4 - 7 Controller Options, Functions ......................................................................................4 - 7

Dynamic Temperature Systems ................................................. 8 - 13 Introduction and Advantages ......................................................................................8 - 9 Unistats® to -60 °C .........................................................................................................10 - 11 Unistats® to -120 °C .......................................................................................................12 - 13

Chillers ......................................................................................... 14 - 21 Introduction and Advantages ......................................................................................14 - 15 Minichiller® and Unichiller® ..........................................................................................16 - 19 RotaCool®, Flow-through Chillers and Immersion Coolers .........................................20 - 21

Baths and Circulators ................................................................. 22 - 33 Introduction, Advantages, Functions ...........................................................................22 - 23 Immersion and Bath Circulators ...................................................................................24 - 25 Bath and Heating Circulators, Variostat® ....................................................................26 - 27 Cooling Circulators, Ministats® .....................................................................................28 - 33

Specials ........................................................................................ 34 - 35 Beer-Force-Ageing-Test Bath, Calibration Bath...........................................................34 Hotbox, Heat Transfer Station......................................................................................35

high precision thermoregulation in Laboratory, Pilot Plant and Production We are the technology leader for high precision thermoregulation solutions in research and industry. Our products ensure precise temperature control throughout the whole world in laboratories, pilot plants and production processes. Our product range offers temperature control solutions for applications from -125 °C to +425 °C. We have been driving technological development in the field of liquid temperature control with continuous innovations since 1968. The introduction of the Unistat technology was a revolution in temperature control, setting the tone for thermodynamics and accuracy today. In addition to dynamic temperature control systems, our product range includes chillers, classic heating & cooling circulators and a range of special solutions and bespoke systems.

3


Controller & Functions

The appropriate controls An easy decision: The modern Pilot ONE®, and the simple MPC® offer a range of functionality to suit all temperature control requirements. The two controllers mean that all applications requirements are covered. Depending on budget and application, a controller can be selected that meets the applications requirements. If only a basic functionality is required, an inexpensive model with an MPC could be chosen. If the application requires

more extensive features, a unit that has the powerful Pilot ONE controller could be the best choice. Pilot ONE models offer the added advantage of functionality upgrades with “E-grades” where the software can be updated by entering a unit specific upgrade code.

MPC® Controller: Simple operation with three keys LED display Basic functions

Economic, low cost, robust: MPC® Controller for simple applications

4

www.huber-usa.com


Description | MPC® • Pilot ONE®

for each application easily interchanged. Thanks to backwards compatibility, it is even possible to retrofit old equipment with modern technology. The base unit and controllers are matched automatically – simply remove the old controller, fit the new one and go!

Controller & Functions

Our unique Plug & Play technology means that all models are equipped with easily replaceable controllers. This technology allows rapid progress in the development of operator comfort and control. Since the 1980s Huber systems have had removable controllers allowing the basic components of our products to be

Pilot ONE® Controller: Comfortable touchscreen operation 5,7“ TFT colour display Professional features USB and Ethernet 13 languages

User friendly, many functions and exchangeable thanks to Plug & Play technology: Pilot ONE®

5


Controller & Functions

Controller functions comparison Pilot ONE®

Pilot ONE®

Pilot ONE®

with E-grade® “Professional“

with E-grade® “Exclusive“

with E-grade® “Basic“

TAC (True Adaptive Control)

TAC (True Adaptive Control)

predefined 1

5 Point

5 Point

2 Point

Monitoring (Level protection, Over temperature protection )

Adjustable limit alarms

Function / Features Controller parameter tuning Calibration program for control sensor (Internal, Process)

Thermoregulation

2

Venting program

Compressor automatic control

Set point limits

10 prg. / 10 steps each (max. 100 steps)

3 prg. / 5 steps each (max. 15 steps)

linear, non-linear

linear

Temperature control mode (Internal, Process)

Maximum heating / cooling power adjustable

5,7“ Touchscreen

5,7“ Touchscreen

5,7“ Touchscreen

graphic, numeric

graphic, numeric

graphic, numeric

VPC (Variable Pressure Control)

3

Programmer Ramp function

Temperature display

NEW

Connections

Display & Operation

Display mode Display resolution Graphic display of temperature curves NEW Calendar, Date, Time Language: D / E / F / IT / ESP / PT / CZ / PL / RUS / CN / JP / KO / TR Temperature format (°C / °F / K)

Various

0,1 °C / 0,01 °C

0,1 °C

Window, full screen, scalable

Window, full screen, scalable

Favourites menu NEW

User menues (Administrator level)

2nd set point

Digital interface RS232

USB interfaces (Host and Device) NEW

Ethernet RJ45 interface

Display mode (screen) switch by swiping

NEW

NEW

Pt100 external sensor connection External control signal / ECS STANDBY

6

Programmable volt-free contact / ALARM 6

Digital interface RS485 7

Alarm signal optical / acoustic

AutoStart (Mains failure automatic)

Plug & Play technology

Technical glossary NEW

Remote control / Data visualisation via Spy Software

E-grade Evaluation versions available (valid for 30 days) NEW

Service data recorder (flight recorder)

AIF (Analogue interface) 0/4-20 mA or 0-10 V

6

NEW

0,1 °C / 0,01 °C Window, full screen, scalable

7

Saving/loading of temperature control programs via USB NEW

Process data logging direct to USB stick NEW

Calendar start

www.huber-usa.com

NEW


s are All E-grade luation va e s a available days valid) versions (30 e. free of charg

MPC®

MPC®

(Circulators)

(Minichiller®/Unichiller®)

predefined

predefined

Offset

Offset

LED, 7 segment

LED, 7 segment

numeric

numeric

0,1 °C

0,1°C / 1°C 4

5

Description | MPC® • Pilot ONE®

1

30 days evaluation version TAC function available

2

For units with integrated over-temperature protection

3

For models with variable-speed pump or an external bypass

4

Display resolution below -10°C and above +100°C: 1°C

5

Only Minichillers/Unichillers “plus“ model

6

Standard on Unistats, otherwise via optional Com.G@te or POKO/ECS Interface

7

Via optional Com.G@te

7


Dynamic Temperature Control Systems

Dynamic Thermoregulation For more than 20 years, the dynamic thermoregulation of the Unistat range introduced a revolution in fluid temperature control. Unistats are the ideal solution for fast and precise thermal control of externally connected applications. In comparison to other circulators, the Unistats offer rapid temperature change and a wide temperature range without fluid

change. There are over 70 models to choose from with cooling powers from 0,7 to 130 kW. What ever the application, Unistats provide professional scale-up offering the same stable process conditions from the development lab to production systems.

• Working temperatures from -125 °C to +425 °C • Previously unachievable performance • Highly accurate, intelligent temperature control • Maximum process stability and reproducibility • The fastest heating and cooling rates • High cooling power from 0,7 to 130 kW • Large temperature range without fluid change • Increased thermal fluid life • Incredibly compact • Brilliant 5,7“ TFT touchscreen with graphic display • Comprehensive warning and safety functions

essories: c c A & s Detail om ber-usa.c www.hu

8

www.huber-usa.com

For more information scan this QR-Code.


With Pilot O Multi NE ® to Contr uch oller

Introduction | Unistat® • Tango® • Grande Fleur® • Petite Fleur®

HEATING & COOLING -125 °C ... +425 °C

9


Dynamic Temperature Control Systems

- 55 °C Models from 0,7 to 21 kW

| Unistat® tango® | | Petite Fleur® |

VPC

Variable Pressure Control

| Unistat® 510w |

ATEX

ATEX Solutions (Option)

Additional Heating

| Unistat® 430 |

(Option) Model

Working Temperature to -55 °C Range (°C) Petite Fleur®* -40...200 Petite Fleur® w* -40...200 Petite Fleur®-eo* -40...200 Grande Fleur®* -40...200 Grande Fleur® w* -40...200 Grande Fleur®-eo* -40...200 Grande Fleur® w-eo* -40...200 Unistat® tango® -45...250 Unistat® tango® w* -45...250 Unistat® tango® wl -45...250 Unistat® 405 -45...250 Unistat® 405w -45...250 Unistat® 410 -45...250 Unistat® 410w -45...250 Unistat® 425 -40...250 Unistat® 425w -40...250 Unistat® 430 -40...250 Unistat® 430w -40...250 Unistat® 510 -50...250 Unistat® 510w -50...250 Unistat® 515w -55...250 Unistat® 520w -55...250 Unistat® 525 -55...250 Unistat® 525w -55...250 Unistat® 527w -55...250 Unistat® 530w -55...250 1

10

integrated VPC pressure control

www.huber-usa.com

2

Pump max. Heating Cooling Power (kW) at (°C) VPC Power (l/min) (bar) (kW) 250 200 100 0 -20 -40 33 0,91 1,5 – 0,48 0,48 0,45 0,27 0,04 33 0,91 1,5 – 0,48 0,48 0,45 0,27 0,04 33 0,91 1,5 – 0,48 0,48 0,45 0,27 0,04 38 0,91 1,5 – 0,6 0,6 0,6 0,35 0,04 38 0,91 1,5 – 0,6 0,6 0,6 0,35 0,04 38 0,91 1,5 – 0,6 0,6 0,6 0,35 0,04 38 0,91 1,5 – 0,6 0,6 0,6 0,35 0,04 55 0,91 3,0 0,7 0,7 0,7 0,7 0,4 0,06 55 0,91 3,0 0,7 0,7 0,7 0,7 0,4 0,06 55 0,91 3,0 0,7 0,7 0,7 0,7 0,4 0,06 55 0,91 3,0 1,0 1,0 1,0 1,0 0,6 0,15 55 0,91 3,0 1,3 1,3 1,3 1,3 0,7 0,15 55 0,91 3,0 1,7 2,5 2,5 1,5 0,8 0,2 55 0,91 3,0 1,7 2,5 2,5 1,5 0,8 0,2 105 1,52 2,65 2,0 2,0 2,0 2,5 1,8 0,2 105 1,52 2,65 2,8 2,8 2,8 2,5 1,9 0,2 90 1,72 5,3 3,5 3,5 3,5 3,5 2,2 0,3 90 1,72 5,3 3,5 3,5 3,5 3,5 2,2 0,3 105 1,52 9,0 5,3 5,3 5,3 5,3 2,8 0,9 105 1,52 9,0 5,3 5,3 5,3 5,3 2,8 0,9 105 1,52 9,0 7,0 7,0 7,0 5,3 2,8 0,9 60 1,52 9,0 6,0 6,0 6,0 6,0 4,2 1,5 60 1,52 9,0 10,0 10,0 10,0 7,0 4,2 1,5 60 1,52 9,0 10,0 10,0 10,0 7,0 4,2 1,5 90 2,52 6,0 7,0 12,0 12,0 12,0 6,0 2,0 90 2,52 16,0 7,0 19,0 21,0 16,0 9,0 3,0

VPC pressure control via optional bypass

208 V option available

3

Dimensions

Cat.No.

G

Power Supply

W x D x H (inch) 10,2 x 17,7 x 19,8 10,2 x 17,7 x 19,8 10,2 x 17,7 x 19,8 11,6 x 21,3 x 22,2 11,6 x 21,3 x 22,2 11,6 x 21,3 x 22,2 11,6 x 21,3 x 22,2 16,8 x 12,1 x 24,8 16,8 x 10,6 x 24,8 16,8 x 12,1 x 24,8 16,8 x 12,1 x 24,8 16,8 x 12,1 x 24,8 18,1 x 21,8 x 47,3 16,8 x 14,2 x 24,8 18,1 x 21,8 x 57,2 18,1 x 21,8 x 57,2 18,1 x 21,8 x 57,2 18,1 x 21,8 x 57,2 43,3 x 29,7 x 53,9 18,1 x 21,8 x 57,2 18,1 x 21,8 x 57,2 21,3 x 23,8 x 52,4 50,8 x 29,0 x 62,8 21,3 x 23,8 x 52,4 21,3 x 27,7 x 58,7 21,3 x 27,7 x 58,7

1030.0007.01 1030.0009.01 1030.0012.01 1041.0002.01 1041.0008.01 1041.0005.01 1041.0011.01 1000.0018.01 1000.0023.01 1000.0024.01 1002.0019.01 1002.0020.01 1031.0011.01 1031.0006.01 1005.0064.01 1005.0067.01 1005.0070.01 1005.0073.01 1005.0088.01 1005.0076.01 1032.0008.01 1006.0023.01 1033.0017.01 1033.0010.01 1034.0017.01 1034.0019.01

3 3 3 3 3 3 3 3 3 3 3 3 3 3 35 35 35 35 35 35 4 4 4 4 4 4

115 V, 1~ 60 Hz3 115 V, 1~ 60 Hz3 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz3 115 V, 1~ 60 Hz3 115 V, 1~ 60 Hz3 115 V, 1~ 60 Hz3 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 460 V, 3~ 60 Hz 208 V, 2~ 60 Hz 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3

*Model uses natural refrigerant as standard, for all other models available on request Flat built models available on request


Models | Unistat®

Natural Refrigerant!

| Unistat® 815w |

| Unistat® 615w |

| Unistat® 825 |

Save time, increase productivity: Petite Fleur, Grande Fleur, Tango and Unistats are proven to be the best performing temperature control systems on the market.

- 85 °C

| Unistat® 705w |

Air- or water-cooled

www.huber-usa.com/casestudies

Model to -60 °C Unistat® 610 Unistat® 610w Unistat® 615w Unistat® 620w Unistat® 625w Unistat® 630w Unistat® 635w Unistat® 640w Unistat® 645w Unistat® 650w Unistat® 680w 2

Working Temperature

Pump max. VPC

Range (°C) -60...200 -60...200 -60...200 -60...200 -60...200 -60...200 -60...200 -60...200 -60...200 -60...200 -60...200

(l/min) 60 60 60 90 90 110 110 110 130 130 130

VPC pressure control via optional bypass

3

(bar) 1,52 1,52 1,52 2,52 2,52 2,52 2,52 2,52 4,02 4,02 4,02

Heating Power (kW) 9,0 9,0 16,0 16,0 16,0 24,0 24,0 32,0 32,0 48,0 96,0

208 V option available

Cooling Power (kW) at (°C) 200 7,0 7,0 9,5 12,0 16,0 22,0 27,0 32,0 45,0 65,0 130,0

100 7,0 7,0 9,5 12,0 16,0 22,0 27,0 32,0 45,0 65,0 130,0

0 7,0 7,0 9,5 12,0 16,0 21,0 27,0 35,0 45,0 65,0 130,0

-20 6,4 6,4 8,0 12,0 15,0 20,0 25,0 30,0 42,0 56,0 80,0

-40 -60 3,3 0,8 3,3 0,8 4,8 1,2 6,5 1,8 7,4 2,2 14,0 5,0 18,0 6,0 18,0 6,0 22,0 7,0 30,0 11,0 60,0 20,0

Working Pump max. Heating Cooling Power (kW) at (°C) Temperature VPC Power to -85 °C Range (°C) (l/min) (bar) (kW) 250 200 100 0 -20 -40 -60 Unistat® 705 -75...250 55 0,91 3,0 0,6 0,6 0,6 0,65 0,6 0,6 0,3 Unistat® 705w -75...250 55 0,91 3,0 0,6 0,6 0,6 0,65 0,6 0,6 0,3 ® Unistat 815 -85...250 40 0,91 2,6 1,3 1,3 1,3 1,5 1,5 1,4 1,2 Unistat® 815w -85...250 40 0,91 2,6 1,5 1,5 1,5 1,5 1,5 1,4 1,2 Unistat® 825 -85...250 40 0,91 4,0 2,3 2,3 2,3 2,2 2,0 2,0 1,4 Unistat® 825w -85...250 40 0,91 4,0 2,3 2,3 2,3 2,4 2,4 2,4 1,5 Integrated VPC pressure control

2

208 V option available

Cat.No.

G

Power Supply

W x D x H (inch) 50,8 x 28,9 x 62,8 24,8 x 27,7 x 59,8 24,8 x 27,7 x 59,8 28,7 x 31,7 x 59,8 28,7 x 31,7 x 59,8 37,4 x 39,6 x 65,0 37,4 x 39,6 x 65,0 37,4 x 39,6 x 65,0 70,9 x 47,2 x 72,1 70,9 x 47,2 x 72,1 177,2 x 78,7 x 78,7

1007.0042.01 1007.0035.01 1007.0038.01 1008.0044.01 1008.0047.01 1009.0024.01 1009.0025.01 1010.0008.01 1011.0007.01 1012.0006.01 1013.0004.01

4 4 4 4 4 5 5 5 5 5 5

460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz

Options: natural refrigerant, additional heating capacity, air cooled units available on request

Model

1

Dimensions

Dimensions

Cat.No.

G

Power Supply

-80 W x D x H (inch) – 16,7 x 15,8 x 28,4 1001.0022.01 3 208 V, 2~ 60 Hz – 16,7 x 15,8 x 28,4 1001.0023.01 3 208 V, 2~ 60 Hz 0,2 18,1 x 23,8 x 57,7 1014.0055.01 35 460 V, 3~ 60 Hz2 0,2 18,1 x 23,8 x 57,7 1014.0058.01 35 460 V, 3~ 60 Hz2 0,3 18,1 x 23,8 x 57,7 1014.0061.01 4 460 V, 3~ 60 Hz2 0,3 18,1 x 23,8 x 57,7 1014.0064.01 4 460 V, 3~ 60 Hz2

Option: natural refrigerants available on request

11


Dynamic Temperature Control Systems

- 90 °C - 120 °C Models from 3,8 to 36 kW

| Unistat® 930w |

Natural Refrigerant! | Unistat® 915w | Model to -90 °C Unistat® 905 Unistat® 905w Unistat® 912w Unistat® 915w Unistat® 920w Unistat® 925w Unistat® 930w Unistat® 950 Unistat® 950w 1

Working Pump max. Temperature VPC Range (°C) (l/min) (bar) -90...250 40 0,91 -90...250 40 0,91 -90...250 110 1,52 -90...250 110 1,52 -90...200 90 2,52 -90...200 110 2,52 -90...200 110 2,52 -90...200 130 4,52 -90...200 130 4,52

integrated VPC pressure control

2

Model

VPC pressure control via bypass

Working Pump max. Temperature VPC to -120 °C Range (°C) (l/min) (bar) Unistat® 1005w -120...100 30 0,91 ® Unistat 1015w -120...100 44 1,52

1

12

integrated VPC pressure control

www.huber-usa.com

2

Heating Cooling Power (kW) at (°C) Dimensions Power (kW) 250 200 100 0 -20 -40 -60 -80 W x D x H (inch) 6,0 4,0 4,0 3,8 3,6 3,5 3,5 2,2 0,7 21,3 x 25,8 x 59,1 6,0 4,5 4,5 4,5 4,5 4,5 4,0 2,5 0,7 21,3 x 25,8 x 59,1 6,0 7,0 7,0 7,0 7,0 7,0 6,0 3,5 0,9 24,8 x 27,7 x 61,6 6,0 11,0 11,0 11,0 11,0 11,0 8,0 4,0 1,1 24,8 x 27,7 x 61,6 16,0 – 11,0 11,0 11,0 11,0 10,0 8,0 2,0 37,4 x 47,4 x 65,0 16,0 – 16,0 16,0 16,0 16,0 15,0 13,5 3,5 37,4 x 47,4 x 65,0 32,0 – 19,0 19,0 20,0 20,0 20,0 15,0 5,0 37,4 x 47,4 x 65,0 32,0 – 30,0 30,0 30,0 30,0 30,0 24,0 10,0 130,5 x 58,5 x 119,7 32,0 – 36,0 36,0 36,0 36,0 36,0 25,0 10,0 103,5 x 51,2 x 76,0

Heating Power (kW) 2,65 5,3

VPC pressure control via bypass

3

208 V option available

0 1,5 2,5

-20 1,5 2,5

-40 1,5 2,5

G

Power Supply

1035.0014.01 1035.0016.01 1016.0030.01 1036.0008.01 1017.0030.01 1017.0033.01 1017.0036.01 1018.0010.01 1018.0011.01

4 4 4 4 4 4 5 5 5

460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz3 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz

Cat.No.

G

Power Supply

Option: natural refrigerants available on request

Cooling Power (kW) at (°C) 100 1,5 2,5

Cat.No.

-60 1,4 2,5

-80 1,4 2,0

Dimensions -100 1,0 2,0

Option: natural refrigerants available on request

W x D x H (inch) 27,6 x 31,7 x 59,8 37,4 x 47,4 x 65,0

1019.0007.01 4 460 V, 3~ 60 Hz 1020.0011.01 5 460 V, 3~ 60 Hz


Models | Unistat® High Temperature Circulators

High Temperature Circulators Advantages: K Small space required K Low fill-volume K High Pump capacity K Rapid, efficient filling of the complete application – with venting K +60 °C max. expansion tank temperature K Plug & Play technology K Simple operation K High level of safety through constant monitoring

High-precision and space saving temperature control up to +425 °C. The new HT circulators of the Unistat TR401 range set new standards in safety, easy operation, and rapid, dynamic temperature control. The Unistat TR401w HT model features an integral stepper motor to control the HT-Cooling, level protection and configurable overtemperature protection. Its minimal internal volume allows the shortest heat-up times to be achieved, while at the same time the maximum expansion tank temperature is limited to +60 °C. The working life and properties of the thermal fluid are also protected, by avoiding direct contact between the hot fluid and atmosphere.

| Unistat® T340w HT |

| Unistat® T401 |

Model

Temperature Range (°C) 50...400 (15) 50...400 80...425

Unistat® TR401 Unistat® TR401w HT Unistat® TR402 Model

1

Temperature Range

| Unistat® T305 |

Pump max. VPC (l/min) 31 26 31

(bar) 0,91 0,81 1,01

Unistat® T305 Unistat® T305 HT Unistat® T305w HT

(°C) 65...300 65...3003 (15) 65...300

(l/min) 45 55 45

(bar) 0,91 1,01 0,91

Heating Power (kW) 4,5 4,8 4,8

Unistat® T320w HT Unistat® T330w HT Unistat® T340w HT Unistat® T402

(15) 65...300 (15) 65...300 (15) 65...300 80...425

60 60 60 45

1,52 2,52 2,52 0,92

12,0 24,0 48,0 6,0

integrated VPC pressure control

2

Pump max. VPC

Heating Power (kW) 6,0 6,0 6,0

VPC pressure control via bypass

3

| Unistat® T320w HT |

400 – 10,0 –

Cooling Power (kW) at (°C) 300 200 – – 10,0 10,0 – –

400 – – –

Cooling Power (kW) at (°C) 300 200 – – 3,2 2,3 10,0 10,0

– – – –

10,0 10,0 10,0 –

10,0 10,0 10,0 –

Dimensions

Cat.No.

G

Power Supply

W x D x H (inch) 11,3 x 14,9 x 35,0 11,3 x 14,9 x 35,0 11,3 x 14,9 x 34,3

1028.0010.01 1028.0011.01 1028.0005.01

3 3 3

208 V, 3~ 60 Hz 208 V, 3~ 60 Hz 208 V, 3~ 60 Hz

Dimensions

Cat.No.

G

Power Supply

100 – 0,6 10,0

W x D x H (inch) 16,7 x 9,8 x 24,8 16,7 x 9,8 x 24,8 16,7 x 9,8 x 24,8

1003.0022.01 1003.0014.01 1003.0015.01

3 3 3

208 V, 3~ 60 Hz 208 V, 3~ 60 Hz 208 V, 3~ 60 Hz

6,0 6,0 6,0 –

18,1 x 21,8 x 52,4 18,1 x 21,8 x 52,4 23,6 x 27,7 x 59,8 19,9 x 15,8 x 30,1

1004.0021.01 1004.0023.01 1024.0009.01 1038.0004.01

35 35 35 3

460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 208 V, 3~ 60 Hz

100 – 10,0 –

Lowest working temperature 15 K above ambient temperature

13


Umwälzkühler

Circulating Chillers / Immersion Coolers Many applications depend on a reliable source of cooling. Cir-

Efficient energy management in all Huber chillers

culating chillers in the Unichiller range offer an ideal solution for

ensures low operating costs and reduced usage of

environmentally friendly and economical cooling in laboratory

valuable fresh water. Huber circulating chillers are

and industry. There are over 50 air and water cooled models to

a resource saving solution with a quick return on

choose from, with cooling powers from 0,3 to 50 kW.

investment.

• Working temperatures from -20 °C to +80 °C • High cooling powers up to 50 kW • Powerful circulation pumps up to 220 l/min • Modern energy management • Space saving tower design • Robust stainless steel construction • Safe for continuous operation, with alarm and warning functions • Highly accurate temperature control • Option for heating / temperatures up to +100 °C • Extensive features (depending on model) with Pt100 sensor connection, RS232, 5 point calibration, heating, etc.

essories: c c A & s Detail om ber-usa.c u .h w w w

14

www.huber-usa.com

For more information scan this QR-Code.


With Pilot ON ® and M E P ® Contr C oller

Introduction | Unichiller® • Minichiller® • RotaCool®

COOLING

TO -90°C

15


Chillers (bench top models)

Minichiller® Small, robust and cost effective with a stainless steel casing, the Minichiller is the smallest Unichiller in the world. Minichillers are available with air or water-cooled refrigeration systems. They are fitted with an illuminated level indicator, overflow and drain on the front. The filling port is on the top of the unit.

| Minichiller® |

| Unichiller® 006-MPC® |

Model

Working Temp. Pump max . Range (°C) (l/min) (bar) Minichiller®* -20...40 (80)** 20 0,2 Minichiller® w* -20...40 (80)** 20 0,2 Unichiller® 003-MPC®* -5...40 20 0,2 Unichiller® 006-MPC®* -20...40 33 0,7 Unichiller® 007-MPC® -20...40 25 2,5 Unichiller® 010-MPC® -20...40 25 2,5 Unichiller® 012-MPC® -20...40 25 2,5 Unichiller® 012w-MPC® -20...40 25 2,5 Unichiller® 015-MPC® -20...40 25 2,5 Unichiller® 015w-MPC® -20...40 25 2,5 Unichiller® 022-MPC® -10...40 25 2,5 Unichiller® 022w-MPC® -10...40 25 2,5 Unichiller® 025-MPC® -10...40 25 2,5 Unichiller® 025w-MPC® -10...40 25 2,5

Cooling Power (kW) at (°C) 15 0 -10 0,3 0,2 0,14 0,3 0,2 0,14 0,28 0,2 – 0,6 0,5 0,35 0,7 0,55 0,4 1,0 0,8 0,5 1,2 1,0 0,7 1,2 1,0 0,7 1,5 1,0 0,7 1,5 1,0 0,7 2,2 1,6 1,0 2,2 1,6 1,0 2,5 2,0 1,2 2,5 2,0 1,2

Option: Heating for Minichiller® 1 kW, for Unichiller® models 2 kW (additional cost) *Units use natural refrigerant as standard, for all other models available on request

16

www.huber-usa.com

Dimensions W x D x H (inch) 8,9 x 14,2 x 15,0 8,9 x 14,2 x 15,0 10,0 x 17,7 x 15,8 11,0 x 19,3 x 16,3 13,8 x 16,9 x 24,5 13,8 x 16,9 x 24,5 16,5 x 18,9 x 22,8 13,8 x 16,9 x 24,5 16,5 x 18,9 x 22,8 13,8 x 16,9 x 24,5 18,1 x 23,2 x 29,3 16,5 x 18,9 x 22,8 18,1 x 23,2 x 29,3 16,5 x 18,9 x 22,8

Mobile with trolley – – – – Height: 27,6 Height: 27,6 Height: 26,0 Height: 27,6 Height: 26,0 Height: 27,6 incl. Height: 26,0 incl. Height: 26,0

Cat.No.

G

3006.0029.99 3006.0030.99 3035.0002.99 3007.0021.99 3012.0012.99 3012.0013.99 3009.0010.99 3012.0014.99 3009.0009.99 3012.0015.99 3010.0005.99 3009.0011.99 3010.0006.99 3009.0012.99

2 2 2 3 3 3 3 3 3 3 3 3 3 3

EO Models (for externally open applications) from Unichiller® 007-MPC® on request ** Permissible temperature in return line +80°C

Power Supply 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz


Models | Unichiller® • Minichiller®

| Unichiller® 007-MPC®-H |

| Unichiller® 022-MPC® |

Natural Refrigerant!

Minichiller®, Unichiller® with MPC® plus Model Minichiller® plus* Minichiller® w plus* Unichiller® 003-MPC® plus* Unichiller® 006-MPC® plus* Unichiller® 007-MPC® plus Unichiller® 010-MPC® plus Unichiller® 012-MPC® plus Unichiller® 012w-MPC® plus Unichiller® 015-MPC® plus Unichiller® 015w-MPC® plus Unichiller® 022-MPC® plus Unichiller® 022w-MPC® plus Unichiller® 025-MPC® plus Unichiller® 025w-MPC® plus

Working Temp. Pump max. Range (°C) (l/min) (bar) -20...40 (80)** 20 0,2 -20...40 (80)** 20 0,2 -5...40 20 0,2 -20...40 33 0,7 -20...40 25 2,5 -20...40 25 2,5 -20...40 25 2,5 -20...40 25 2,5 -20...40 25 2,5 -20...40 25 2,5 -10...40 25 2,5 -10...40 25 2,5 -10...40 25 2,5 -10...40 25 2,5

Cooling Power (kW) at (°C) 15 0 -10 0,3 0,2 0,14 0,3 0,2 0,14 0,28 0,2 – 0,6 0,5 0,35 0,7 0,55 0,40 1,0 0,8 0,5 1,2 1,0 0,7 1,2 1,0 0,7 1,5 1,0 0,7 1,5 1,0 0,7 2,2 1,6 1,0 2,2 1,6 1,0 2,5 2,0 1,2 2,5 2,0 1,2

Dimensions W x D x H (inch) 8,9 x 14,2 x 15,0 8,9 x 14,2 x 15,0 10,0 x 17,7 x 15,8 11,0 x 19,3 x 16,3 13,8 x 16,9 x 24,5 13,8 x 16,9 x 24,5 16,5 x 18,9 x 22,8 13,8 x 16,9 x 24,5 16,5 x 18,9 x 22,8 13,8 x 16,9 x 24,5 18,1 x 23,2 x 29,3 16,5 x 18,9 x 22,8 18,1 x 23,2 x 29,3 16,5 x 18,9 x 22,8

Mobile with trolley – – – – Height: 27,6 Height: 27,6 Height: 26,0 Height: 27,6 Height: 26,0 Height: 27,6 incl. Height: 26,0 incl. Height: 26,0

Cat.No.

G

3006.0043.99 3006.0044.99 3035.0005.99 3007.0022.99 3012.0072.99 3012.0073.99 3009.0050.99 3012.0074.99 3009.0051.99 3012.0075.99 3010.0028.99 3009.0052.99 3010.0029.99 3009.0053.99

2 2 2 3 3 3 3 3 3 3 3 3 3 3

Power Supply 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz

plus = with digital interface RS232 Option: Heating for Minichiller® 1 kW, for Unichiller® models 2 kW (additional costs) EO Models (for externally open applications) from Unichiller® 007-MPC® plus on request *Units use natural refrigerant as standard, for all other models available on request ** Permissible temperature in return line +80°C

17


Chillers (tower models)

Unichiller® with air cooled refrigeration

to 40 kW [kW] air cooled models from 1,7 to 40 kW

| Unichiller® 045T |

| Unichiller® 110T |

Model Unichiller® 017T Unichiller® 020T Unichiller® 025T Unichiller® 040T Unichiller® 045T Unichiller® 055T Unichiller® 060T Unichiller® 080T Unichiller® 100T Unichiller® 110T Unichiller® 130T* Unichiller® 150T* Unichiller® 160T* Unichiller® 200T* Unichiller® 210T* Unichiller® 250T* Unichiller® 260T* Unichiller® 300T* Unichiller® 400T* * without trolley

18

Working Temp. Pump max. Cooling Power (kW) at (°C) Range (°C) Type (l/min) (bar) 15 0 -10 -20 -10...40 B 30 3,8 1,7 0,9 0,4 – -20...40 B 30 3,8 2,0 2,0 1,5 0,8 -10...40 B 30 3,8 2,5 1,2 0,6 – -10...40 B 30 3,8 4,0 2,5 1,5 – -20...40 B 30 3,8 4,5 4,5 2,9 1,5 -10...40 C3 65 6,4 5,5 3,0 1,3 – -20...40 C3 97 6,4 6,0 6,0 3,9 2,0 -10...40 C3 97 6,4 8,0 4,8 2,5 – -20...40 C3 97 6,4 10,0 10,0 6,5 2,5 -10...40 C3 97 6,4 11,0 6,0 2,7 – -10...40 C3 97 6,4 13,0 7,0 4,5 – -20...40 D3 220 4,7 15,0 15,0 9,7 3,7 -10...40 C3 96 6,4 16,0 8,8 4,0 – -10...40 D3 220 4,7 20,0 11,0 5,0 – -20...40 D3 220 4,7 21,0 21,0 13,6 5,2 -10...40 D3 220 4,7 25,0 14,0 6,2 – -20...40 D3 220 4,7 26,0 26,0 13,6 5,2 -10...40 D3 220 4,7 30,0 16,5 7,5 – -10...40 D3 220 4,7 40,0 22,0 10,0 – Option: Heating 2 kW to +100 °C (additional cost)

www.huber-usa.com

Dimensions W x D x H (inch) 17,7 x 20,1 x 48,4 17,7 x 20,1 x 48,4 17,7 x 20,1 x 48,4 19,7 x 21,7 x 57,1 19,7 x 21,7 x 57,1 23,6 x 27,2 x 63,5 23,6 x 27,2 x 63,5 23,6 x 31,1 x 63,5 23,6 x 31,1 x 63,5 23,6 x 31,1 x 63,5 35,6 x 54,8 x 71,7 35,6 x 54,8 x 71,7 35,6 x 54,8 x 71,7 35,6 x 54,8 x 71,7 35,6 x 85,5 x 73,6 35,6 x 85,5 x 73,6 35,6 x 85,5 x 73,6 35,6 x 85,5 x 73,6 35,6 x 85,5 x 73,6

(W/dm³) at 15°C 0°C 6,0 3,2 7,1 7,1 8,8 4,2 10,0 6,2 11,2 11,2 9,0 4,9 9,8 9,8 10,5 6,3 13,1 13,1 14,4 7,8 5,7 3,1 6,5 6,5 7,0 3,8 8,7 4,8 5,7 5,7 6,8 3,8 7,1 7,1 8,2 4,5 10,9 6,0

EO Models (for externally open applications) on request

Cat.No.

G

3013.0007.01 3013.0008.01 3013.0009.01 3014.0005.01 3014.0006.01 3015.0006.01 3015.0007.01 3016.0003.01 3017.0005.01 3017.0006.01 3018.0005.01 3019.0005.01 3018.0006.01 3019.0006.01 3020.0009.01 3020.0010.01 3020.0011.01 3020.0012.01 3021.0003.01

3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 5 5 5 5

Power Supply 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz

Option: natural refrigerant available on request


Models | Unichiller®

Unichiller® with water cooled refrigeration

to 50 kW [kW] water cooled models from 1,7 to 50 kW

Natural Refrigerant!

| Unichiller® 130Tw | | Unichiller® 025Tw | Model

Working Temp. Pump max. Range (°C) Type (l/min) (bar) Unichiller® 017Tw -10...40 B 30 3,8 Unichiller® 020Tw -20...40 B 30 3,8 Unichiller® 025Tw -10...40 B 30 3,8 Unichiller® 030Tw -20...40 B 30 4,1 Unichiller® 040Tw -10...40 B 30 4,1 Unichiller® 055Tw -10...40 C3 65 6,4 Unichiller® 060Tw -20...40 C3 122 5,6 Unichiller® 080Tw -10...40 C3 97 6,4 Unichiller® 100Tw -20...40 C3 97 6,4 Unichiller® 110Tw -10...40 C3 97 6,4 Unichiller® 130Tw -10...40 C3 97 6,4 Unichiller® 150Tw -20...40 D3 200 4,7 Unichiller® 160Tw -10...40 C3 114 6,7 Unichiller® 200Tw -10...40 D3 200 4,7 Unichiller® 210Tw -20...40 D3 200 4,7 Unichiller® 250Tw -10...40 D3 200 4,7 Unichiller® 260Tw -20...40 D3 220 4,7 Unichiller® 300Tw -10...40 D3 220 4,7 Unichiller® 400Tw -10...40 D3 220 4,7 Unichiller® 500Tw* -10...40 D3 220 4,5 1 * without trolley 208 V option available Option: natural refrigerant available on request

Cooling Power (kW) at (°C) 15 0 -10 -20 1,7 0,9 0,4 – 2,0 2,0 1,5 0,8 2,5 1,2 0,6 – 3,0 3,0 2,0 1,0 4,0 2,5 1,5 – 5,5 4,0 2,0 – 6,0 6,0 3,8 2,1 8,0 4,65 2,35 – 10,0 10,0 6,3 3,0 11,0 5,8 2,55 – 13,0 7,0 4,5 – 15,0 15,0 10,0 5,0 16,0 9,5 5,5 – 20,0 10,7 4,7 – 21,0 21,0 15,5 9,5 25,0 14,0 6,2 – 26,0 26,0 20,0 12,0 30,0 16,0 7,1 – 40,0 21,0 10,0 – 50,0 30,0 – –

Option: Heating 2 kW to +100 °C (additional cost)

Dimensions W x D x H (inch) 15,7 x 17,3 x 48,4 15,7 x 17,3 x 48,4 15,7 x 17,3 x 48,4 15,7 x 17,3 x 48,4 15,7 x 17,3 x 48,4 19,7 x 21,7 x 49,7 23,6 x 23,6 x 57,1 19,7 x 21,7 x 49,7 23,6 x 23,6 x 57,1 23,6 x 23,6 x 57,1 23,6 x 23,6 x 57,1 29,9 x 31,5 x 61,4 23,6 x 23,6 x 57,1 29,9 x 31,5 x 61,4 29,9 x 31,5 x 61,4 29,9 x 31,5 x 61,4 29,9 x 31,5 x 61,4 29,9 x 35,4 x 61,4 29,9 x 35,4 x 61,4 39,4 x 43,4 x 62,2

(W/dm³) at 15°C 0°C 8,8 4,6 10,3 10,3 12,9 6,2 15,5 15,5 20,7 12,9 15,8 11,5 11,5 11,5 23,0 13,4 19,2 19,2 21,1 11,1 24,9 13,4 15,8 15,8 30,7 18,2 21,1 11,3 22,1 22,1 26,4 14,8 27,4 27,4 31,6 16,9 42,2 22,1 37,8 19,7

Cat.No.

G

3024.0022.01 3024.0026.01 3024.0032.01 3025.0023.01 3025.0006.01 3026.0008.01 3026.0047.01 3026.0010.01 3027.0010.01 3027.0011.01 3027.0012.01 3028.0012.01 3027.0013.01 3028.0013.01 3028.0014.01 3028.0015.01 3028.0016.01 3029.0005.01 3029.0006.01 3030.0003.01

3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 5 5 5 5 5

Power Supply 208 V, 2~ 60 Hz 115 V, 1~ 60 Hz1 115 V, 1~ 60 Hz1 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz

EO Models (for externally open applications) on request

19


Chillers

RotaCool® This chiller is unique on the global market due to its space saving L-form. The additional space required on the laboratory table is zero! Abracadabra: placed on rotary evaporator the RotaCool virtually disap-

pears completely. The RotaCool is a product to provide a dedicated cooling service to all small bench top Rotary Evaporators.

Natural Refrigerant!

Accessories Additional extension plate (112 mm) Vacuum pump mounting

Model

RotaCool®

Working Temp. Range (°C) -10...40

Natural refrigerant as standard

20

www.huber-usa.com

Cat. G No. 10270 1 10275 1

Cooling Power (kW) at (°C) 15 0 -10 0,42 0,35 0,22

| 10275 | | 10270 |

Pump Data Pump max. max. Suction (l/min) (bar) (l/min) (bar) 20 0,2 17 0,18

Dimensions WxDxH (inch) 18,5 x 22,8 x 16,5

Cat.No.

G

Power Supply

3033.0008.99

3

110 V, 1~ 50/60 Hz


Models | RotaCool® • Flow-through Chillers • Immersion Coolers

Flow-through Chillers Flow-through Chillers are designed for simple, low demand cooling applications. They are commonly used in combination with the CC-202C or CC-205B series to remove heat in order to cool a process back to room temperature. Model

DC®30 DC®31 DC®32

Working Temp. Cooling Power (kW) at Dimensions Range WxDxH (°C) 15°C 0°C -20°C (inch) -30...50 0,2 0,15 0,07 7,5 x 9,8 x 14,2 -30...50 0,4 0,35 0,10 9,8 x 12,2 x 15,8 -30...50 0,6 0,47 0,12 11,0 x 13,4 x 18,1

Cat.No.

G

Power Supply

3000.0002.99 3001.0002.99 3002.0002.99

2 2 2

115 V, 1~ 60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz

All units use natural refrigerant as standard

Natural Refrigerant!

| DC 30 | ®

Immersion Coolers ”Dip“ or ”Immersion“ coolers are ideal for simple cooling applications when low temperatures are required such as vapour traps or for cooling individual flasks. They are also commonly used to remove heat from the baths in the ”A“ and ”B“ series. The units with an “E” have the capability to control the temperature to a stability of +/- 0,5 K to DIN 12876. All models can be delivered with a flexible evaporator coil (no extra cost). The model name and Cat.No. have the suffix ”F“. Flexible probes & custom probes available.

| TC®100E |

| TC®50 | | TC®45-F |

Model

TC®45 TC®45E TC®50 TC®50E TC®100 TC®100E

Working Temperature Range (°C) -45...100 -45...100 -50...50 -50...50 -100...40 -100...40

Cooling Power (kW) at 0°C 0,24 0,24 0,3 0,3 0,16 0,16

-20°C 0,18 0,18 0,26 0,26 0,15 0,15

-30°C 0,1 0,1 0,2 0,2 0,14 0,14

-90°C – – – – 0,07 0,07

Dimensions WxDxH (inch) 7,5 x 11,6 x 14,2 7,5 x 11,6 x 14,2 10,2 x 13,0 x 16,3 10,2 x 13,0 x 16,3 11,6 x 18,5 x 22,1 11,6 x 18,5 x 22,1

Cat.No. “Standard“ 3003.0005.99 3003.0006.99 3004.0005.99 3004.0006.99 3005.0005.99 3005.0006.99

Cat.No. with flexible evaporator 3003.0007.99 3003.0008.99 3004.0007.99 3004.0008.99 3005.0007.99 3005.0008.99

G

Power Supply

2 2 2 2 2 2

115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz

All units use natural refrigerant as standard

21


Baths and Circulators

Baths and Circulators The circulators are split into two product lines, the Compati-

applications from -90  °C to +200  °C. Immer-

ble Control models and the simpler MPC models. Both product

sion or bridge circulators are suitable for ther-

lines represent classically constructed laboratory circulators with

mal control of existing baths. The Ministat, the

open baths. Baths and circulators for heating applications up to

smallest cooling and heating circulator in the

+300 °C are available, as well as models for heating and cooling

world, is the first choice for operation in fumehoods or integrating into systems.

• Working temperatures from -90 °C to +300 °C • Models for internal and external temperature control • High heating and cooling powers up to 7 kW • Powerful controllable circulation pumps • Function expansion with the E-grade system is available at any time • High precision cascade temperature control • Large and full colour 5,7“ TFT touchscreen • Programmer with calendar / clock function • Extended range of languages including a selection of European and Asian • Comprehensive warning and safety functions

: cessories c A & s il Deta r-usa.com e b u .h w ww

22

www.huber-usa.com

For more information scan this QR-Code.


With Pilot ON ® and M E P ® Contr C oller

Introduction | MPC® • Compatible Control • Ministat® • Variostat®

HEATING & COOLING -90 °C ... +300 °C

23


Baths and Circulators

Immersion Circulators Immersion thermostats are the basis for many device combinations with polycarbonate or stainless steel bath vessels. There is a universally usable screw clamp in the scope of delivery for the thermostats to be very easily mounted on any desired vessels. Negative temperatures of down to -30°C can be realised in combination with a cooling bath. All models are fitted with a powerful pressure/suction pump and meet the requirements of safety class III (FL) for use with flammable fluids. A pump adapter for external temperature control and cooling coils for a cooling water connection can be obtained as accessories.

Model

Temperature Temperature Range Stability1 (°C) (K) CC®-E (-30)* 25...200 0,01 MPC®-E (-30)* 25...200 0,05 CC®-E xd (-30)* 25...200 0,01

Heating Power (kW) 1,5 1,5 1,5

| CC®-E |

| MPC®-E |

Pump Data max. Pressure max. Suction (l/min) (bar) (l/min) (bar) 27 0,7 25 0,4 20 0,2 17 0,18 20 0,5 15 0,25

Safety Class2 FL, III FL, III FL, III

Dimensions W x D x H / ID3 (inch) 5,2 x 6,3 x 12,4/5,9 5,2 x 6,0 x 12,3/5,9 5,2 x 6,3 x 14,2/7,7

Cat.No.

G

Power Supply

2000.0002.01 1 110 V, 1~ 50/60 Hz 2035.0007.99 1 110 V, 1~ 50/60 Hz 2000.0006.01 1 110 V, 1~ 50/60 Hz

2 to DIN 12876, measured in a stainless steel tank 12 litres FL for flammable liquids, III = adjustable overtemperature protection and addition low-liquid level protection * Auxiliary cooling device required (see glossary „Working Temperature Range“) 1

3

Immersion Depth

Circulators Good things come in small packages! Thanks to their low bath volumes the models CC-104A and MPC104A (with polycarbonate bath) as well as the CC202C and MPC-202C (with stainless steel bath) are especially suitable for controlling the temperature of small external applications. All models are fitted with rear mounted M16x1 pump connections as standard. Models with the Pilot ONE have a speed regulated pressure/suction pump. The temperature constancy, in accordance with DIN12876, is 0,02 K with the Compatible Control models and 0,05 K for the MPC models.

| CC®-202C |

| MPC®-104A | Model

Temperature Range Opening (°C) (inch) CC®-104A (15)* 25...100 Ø1 MPC®-104A (15)* 25...100 Ø1 CC®-202C (-30)* 45...200 Ø1 MPC®-202C (-30)* 45...200 Ø1

Bath Depth (inch) 5,9 5,9 5,9 5,9

Volume (ltr) 4 4 2 2

Heating Pump Data Power max. Pressure max. Suction (kW) (l/min) (bar) (l/min) (bar) 1,5 27 0,7 25 0,4 1,5 20 0,2 17 0,18 1,5 27 0,7 25 0,4 1,5 20 0,2 17 0,18

Dimensions WxDxH (inch) 5,8 x 9,3 x 13,0 5,8 x 9,3 x 13,0 7,0 x 10,2 x 14,0 7,0 x 10,2 x 14,0

Cat.No.

G

Power Supply

2001.0017.01 2037.0027.99 2003.0002.01 2039.0007.99

1 1 1 1

110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz

* Auxiliary cooling device required (see glossary „Working Temperature Range“) Models CC®-202C and MPC®-202C are fitted with an integrated cooling coil as standard. With the models CC®-104A and MPC®-104A the cooling coil is an optional extra.

24

www.huber-usa.com


Models | MPC® • Compatible Control

Circulators with Polycarbonate baths The polycarbonate baths are suitable for use up to 100  °C. An Immersion circulator is mounted on the bath bridge for all models. With a pump adapter, this combination can also be used with external, closed applications. The models with the Pilot ONE have a variable speed pressure/suction pump and are therefore also suitable for externally open applications. | MPC®-118A |

Model

CC®-106A MPC®-106A CC®-108A MPC®-108A CC®-110A MPC®-110A CC®-112A MPC®-112A CC®-118A MPC®-118A

Temperature Heating Range Power Opening (°C) (kW) (inch) (15)* 25...100 1,5 5,1 x 4,3 (15)* 25...100 1,5 5,1 x 4,3 (15)* 25...100 1,5 5,1 x 8,3 (15)* 25...100 1,5 5,1 x 8,3 (15)* 25...100 1,5 5,1 x 12,2 (15)* 25...100 1,5 5,1 x 12,2 (15)* 25...100 1,5 11,9 x 6,3 (15)* 25...100 1,5 11,9 x 6,3 (15)* 25...100 1,5 11,9 x 12,6 (15)* 25...100 1,5 11,9 x 12,6

Bath Depth (inch) 5,9 5,9 5,9 5,9 5,9 5,9 5,9 5,9 5,9 5,9

| CC®-112A |

Pump Data Volume max. Pressure max. Suction (ltr) (l/min) (bar) (l/min) (bar) 6 27 0,7 25 0,4 6 20 0,2 17 0,18 8 27 0,7 25 0,4 8 20 0,2 17 0,18 10 27 0,7 25 0,4 10 20 0,2 17 0,18 12 27 0,7 25 0,4 12 20 0,2 17 0,18 18 27 0,7 25 0,4 18 20 0,2 17 0,18

| MPC®-110A |

Dimensions WxDxH (inch) 5,8 x 12,1 x 13,0 5,8 x 12,1 x 13,0 5,8 x 16,0 x 13,0 5,8 x 16,0 x 13,0 5,8 x 20,0 x 13,0 5,8 x 20,0 x 13,0 13,1 x 14,2 x 13,2 13,1 x 14,2 x 13,2 13,1 x 20,5 x 13,2 13,1 x 20,5 x 13,2

| CC®-108A |

| MPC®-106A |

Cat.No.

G

Power Supply

2001.0008.01 2037.0031.99 2001.0009.01 2037.0032.99 2001.0010.01 2037.0033.99 2001.0011.01 2037.0034.99 2001.0012.01 2037.0035.99

1 1 1 1 1 1 1 1 1 1

110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz

* Auxiliary cooling device required (see glossary „Working Temperature Range“)

Safety class III/FL

Circulators with stainless steel baths The insulated stainless steel baths are suitable for use up to 200 °C. All models have a bridge mounted CC-E and MPC-E immersion circulator. With a pump adapter, this combination can also be used with externally closed and externally open (with option level control) applications. | CC®-225B | Model

CC®-208B MPC®-208B CC®-212B MPC®-212B CC®-215B MPC®-215B CC®-220B MPC®-220B CC®-225B MPC®-225B

Temperature Heating Range Power Opening (°C) (kW) (inch) (-30)* 25...200 1,5 9,1 x 5,0 (-30)* 25...200 1,5 9,1 x 5,0 (-30)* 25...200 1,5 11,4 x 6,0 (-30)* 25...200 1,5 11,4 x 6,0 (-30)* 25...200 1,5 11,4 x 6,0 (-30)* 25...200 1,5 11,4 x 6,0 (-30)* 25...200 1,5 11,4 x 13,0 (-30)* 25...200 1,5 11,4 x 13,0 (-30)* 25...200 1,5 11,4 x 13,0 (-30)* 25...200 1,5 11,4 x 13,0

Bath Depth (inch) 5,9 5,9 5,9 5,9 7,9 7,9 5,9 5,9 7,9 7,9

| MPC®-220B |

| CC®-215B |

Pump Data Volume max. Pressure max. Suction (ltr) (l/min) (bar) (l/min) (bar) 8,5 27 0,7 25 0,4 8,5 20 0,2 17 0,18 12 27 0,7 25 0,4 12 20 0,2 17 0,18 15 27 0,7 25 0,4 15 20 0,2 17 0,18 20 27 0,7 25 0,4 20 20 0,2 17 0,18 25 27 0,7 25 0,4 25 20 0,2 17 0,18

| MPC®-212B |

Dimensions WxDxH (inch) 11,4 x 13,8 x 14,8 11,4 x 13,8 x 14,8 13,8 x 14,8 x 14,8 13,8 x 14,8 x 14,8 13,8 x 14,8 x 16,7 13,8 x 14,8 x 16,7 13,8 x 21,9 x 14,8 13,8 x 21,9 x 14,8 13,8 x 21,9 x 16,7 13,8 x 21,9 x 16,7

| CC®-208B |

Cat.No.

G

Power Supply

2002.0006.01 2038.0031.99 2002.0007.01 2038.0032.99 2002.0008.01 2038.0033.99 2002.0009.01 2038.0034.99 2002.0010.01 2038.0035.99

1 1 1 1 1 1 1 1 1 1

110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz

* Auxiliary cooling device required (see glossary „Working Temperature Range“)

25


Baths and Circulators

Heating bath circulators Heating baths circulators are suitable for temperatures up to +200 °C or +300 °C depending on model. The Compatible Control models have a continuously variable pressure and suction pump. The pump pressure can be controlled with an optional pressure sensor, and so can protect your valuable glass-ware from

| CC®-308B |

| CC®-315B |

| MPC®-205B |

354

| CC®-304B |

breakage. The machines are preferred and used for temperature control of externally connected applications. Additionally there is the possibility to control the temperature of objects placed directly in the open bath.

90

105

7

33

178

Model

CC®-205B

Temperature Range (°C) (-30)* 45...200

Bath Volume (ltr) 5,0

Bath Depth (inch) 5,9

Heating Power (kW) 1,5

Temperature Stability to DIN 12876 (K) 0,02

®

MPC -205B

(-30)* 45...200

5,0

5,9

1,5

0,05

20

0,2

17

CC®-304B

(-20)* 28...300

5,0

6,1

1,5

0,02

33

0,7

22

CC®-308B CC®-315B

(-20)* 28...300 8,5/5,2** (-20)* 28...300 15/8,5**

6,1 7,9

1,5 3,2

0,02 0,02

33 33

0,7 0,7

22 22

* Auxiliary cooling device required (see glossary „Working Temperature Range“)

26

www.huber-usa.com

Pump Data max. Pressure max. Suction (l/min) (bar) (l/min) (bar) 27 0,7 25 0,4

** with displacement insert

Cat.No.

G

Power Supply

2004.0002.01

1 110 V, 1~ 50/60 Hz

0,18

2040.0007.99

1 110 V, 1~ 50/60 Hz

0,4

2005.0002.01

1 110 V, 1~ 50/60 Hz

0,4 0,4

2006.0003.01 2007.0003.01

1 110 V, 1~ 50/60 Hz 1 208 V, 2~ 60 Hz


Models | MPC® • Compatible Control • Variostat®

Position 1

Position 2

Variostat® – the cooling circulator for a variety of baths This unique immersion circulator can thermoregulate a wide range of baths between -30 °C and +150 °C. The innovative construction allows the user ultimate flexibility. The circulation can be adjusted to suit the bath size using the stepless variable speed suction/ pressure pump. The pump can also be controlled with an optional pressure sensor for external applications.

Insulated stainless steel baths are available in three standard sizes or can be made to measure. A drain is fitted as standard on the short side (or on request this can be fitted on the long side). The order number has the suffix L to indicate the drain on the long side (Example 6052-L).

Volume (Litre) 5,5 11,0 22,0

Natural Refrigerant!

End Temp. (°C) -30 -25 -20

Cooling Time* (min) free Bath Opening (inch) with Ethanol to Position 1 Position 2 0°C -10°C -20°C A1 B1 C1 A2 B2 C2 15 30 55 3,4 6,3 – 6,3 3,4 – 30 60 110 7,9 7,9 1,1 7,9 7,8 1,2 65 130 240 11,8 12,6 5,8 12,6 11,7 5,9

*Cooling time, measured with ²∕³ of bath covered

Model

Variostat®

Working Temperature Range (°C) -30...150

Function version available by E-grade®

Bath Heating Pump Data Volume Power max. Pressure max. Suction (ltr) (kW) (l/min) (bar) (l/min) (bar) variable 1,0 27 0,7 20 0,4 Temperature Stability to DIN 12876: 0,02 K

Cooling Power (kW) Cat.No. G Power at (°C) Supply 100 20 0 -20 -30 0,3 0,3 0,2 0,12 0,03 2013.0004.01 2 115 V, 1~ 60 Hz

Natural refrigerant as standard

27


Baths and Circulators

Ministats® Compact cooling circulators Exceptionally compact and powerful, Ministats have been the smallest cooling circulators in the world since 1976. Their compact form allows them to be placed in small spaces, e.g. in a laboratory extraction hood. All three Ministats are now available with air or water cooling. Compliance with DIN 12876, class 3 allows them to be used unsupervised in continual operation. The maximum ambient temperature is +40 °C. The powerful variable speed pressure/suction pump can thermoregulate objects in the bath or external applications. The maximum pressure can be controlled using an optional pressure sensor – VPC (Variable Pressure Control) – which protects delicate glassware. The small volume and high power of the Ministats means exceptionally rapid heating and cooling rates are achieved. Optional displacement inserts reduce the bath volume by approximately 50 % amplifying this effect and reducing moisture absorption in the thermal fluid. All models have Active Cooling Control for cooling power control at the maximum working temperature and an automatic cooling power regulation for energy saving operation and reduced heat dissipation into the lab. The bath opening is large

| Ministat® 125 | Model

Ministat® 125 Ministat® 125w Ministat® 230 Ministat® 230w Ministat® 240 Ministat® 240w

Working Temperature Range (°C) -25...150 -25...150 -40...200 -40...200 -45...200 -45...200

* with displacement insert

28

www.huber-usa.com

enough to allow small objects to be thermoregulated within. All parts in contact with the thermal fluid are made of stainless steel or polycarbonate. Ministats have the Pilot ONE with Plug & Play technology (proven since 1980). In the event of service the controller can be simply swapped. Using a data cable the Ministat can be remotely controlled. The Pilot ONE has a state-of-the-art microprocessor controller and a high precision temperature measurement system for exact and reproducible temperature control. The functionality and TFT-display are supported by Easy Control. Ministats can be fitted with a Com.G@te (NAMUR Standard) allowing them to be integrated into a process control system. Typical applications for the smallest cooling circulator in the world are external closed systems e.g. photometer, refractometer and viscosimeter. Increased functionality with optional accessories: – External pressure sensor for VPC pressure control – Com.G@te (NAMUR Standard): RS232, RS485, programmable volt-free contact, ECS (external control signal), Level monitoring – Calibration and displacement inserts

| Ministat® 230 | Bath Heating Pump Data Volume Depth Power max. Pressure max. Suction (ltr) (inch) (kW) (l/min) (bar) (l/min) (bar) 3,0/1,3* 4,7 1,0 27 0,7 20 0,4 3,0/1,3* 4,7 1,0 27 0,7 20 0,4 3,7/1,7* 5,3 1,5 27 0,7 20 0,4 3,7/1,7* 5,3 1,5 27 0,7 20 0,4 4,9/2,8* 6,2 1,6 27 0,7 20 0,4 4,9/2,8* 6,2 1,6 27 0,7 20 0,4

Temperature Stability to DIN 12876: 0,02 K

| Ministat® 240 | Cooling Power (kW) at (°C) 20 0 -20 -30 0,30 0,21 0,05 – 0,30 0,20 0,10 – 0,42 0,38 0,25 0,14 0,42 0,38 0,25 0,14 0,60 0,55 0,35 0,125 0,60 0,55 0,35 0,125

All units use natural refrigerant as standard

Cat.No.

G

Power Supply

2014.0012.01 2014.0013.01 2015.0012.01 2015.0013.01 2016.0018.01 2016.0019.01

2 2 2 2 2 2

115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz


Models | Ministat®

| Ministat® 230 | | Ministat 240 | ®

| Ministat® 125** |

Features K Compact ergonomic design K Pilot ONE with Plug & Play technology K Large and full colour 5,7“ TFT touchscreen, EASY Control K Connections for RS232, USB and Ethernet K Steplessly variable pump speed for homogeneous temperature distribution in bath or optimal circulation and heat transfer in external applications

K K K K K K K K

Active Cooling Control Pt100 External-Sensor Calibratable temperature sensor Adjustable over temperature and level protection Compliant with DIN12876-1 class 3 Pump connections for external applications Bath opening for thermoregulation of objects in bath Drain tap on front (option)**

VPC

Variable Pressure Control

DIN 12876

Natural Refrigerant!

Our cooling powers are always quoted at full pump speed

Plug & Play 3 years warranty

29


Baths and Circulators

Compatible Control Cooling Circulators The K6 and the more powerful K6s models are compact cooling bath circulators for temperatures from -25 °C to +200 °C. These units are a combination of a cooling bath and immersion circulator, in combination with an integrated pump they are suitable for external open* or closed applications. The CC-E immersion circulator with its suction/pressure pump is suitable for externally open and closed applications. The temperature stability is 0,02  K for the Compatible Control models and 0,05  K for the MPC models. *with optional level control

| CC®-K6 | | CC®-K6s |

| MPC®-K6 | | MPC®-K6s |

Natural Refrigerant!

Model

Working Heating Bath Pump Data Temperature Power Opening Depth Volume max. Pressure max. Suction Range (°C) (kW) (inch) (inch) (ltr) (l/min) (bar) (l/min) (bar) CC®-K6 -25...200 1,5 5,5 x 4,7 5,9 4,5 27 0,7 25 0,4 MPC®-K6 -25...200 1,5 5,5 x 4,7 5,9 4,5 20 0,2 17 0,18 CC®-K6s -25...200 1,5 5,5 x 4,7 5,9 4,5 27 0,7 25 0,4 MPC®-K6s -25...200 1,5 5,5 x 4,7 5,9 4,5 20 0,2 17 0,18 All units use natural refrigerant as standard

30

www.huber-usa.com

Cooling Power (kW) at (°C) 20 0 -20 0,20 0,15 0,05 0,20 0,15 0,05 0,26 0,21 0,05 0,26 0,21 0,05

Dimensions WxDxH (inch) 8,3 x 15,8 x 21,5 8,3 x 15,8 x 21,5 8,3 x 15,8 x 21,5 8,3 x 15,8 x 21,5

Cat.No.

G

Power Supply

2008.0006.01 2008.0023.99 2008.0004.01 2008.0024.99

2 2 2 2

110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz 110 V, 1~ 50/60 Hz


Models | MPC® • Compatible Control

Plug & Play 3 years warranty

| CC®-K20 / CC®-K25 |

| CC®-K12 / CC®-K15 |

| MPC®-K20 / MPC®-K25 |

| MPC®-K12 / MPC®-K15 |

Natural Refrigerant!

Cooling Circulators Combinations of immersion circulators and insulated cooling baths are a low-cost solutions for direct thermoregulation for the temperature range -20/ -30 °C to +200 °C. The cooling baths operate with natural refrigerants. A pump adapter (optional) can be fitted for thermoregulation of externally closed and externally open* applications. Models with the

Model

CC®-K12 MPC®-K12 CC®-K15 MPC®-K15 CC®-K20 MPC®-K20 CC®-K25 MPC®-K25 Safety class III/FL

Pilot ONE have a variable speed pressure/suction pump and are suitable for externally open thermoregulation applications. The temperature stability is 0,02 K for the Compatible Control models and 0,05 K for the MPC models. *with optional level control

Working Heating Bath Pump Data Cooling Power (kW) Temp. Range Power Opening Depth Volume max. Pressure max. Suction at (°C) (°C) (kW) (inch) (inch) (ltr) (l/min) (bar) (l/min) (bar) 0 -10 -20 -20...200 1,5 11,4 x 6,0 5,9 12 27 0,7 25 0,4 0,2 0,12 0,05 -20...200 1,5 11,4 x 6,0 5,9 12 20 0,2 17 0,18 0,2 0,12 0,05 -20...200 1,5 11,4 x 6,0 7,9 15 27 0,7 25 0,4 0,2 0,12 0,05 -20...200 1,5 11,4 x 6,0 7,9 15 20 0,2 17 0,18 0,2 0,12 0,05 -30...200 1,5 11,4 x 13,0 5,9 20 27 0,7 25 0,4 0,35 0,27 0,16 -30...200 1,5 11,4 x 13,0 5,9 20 20 0,2 17 0,18 0,35 0,27 0,16 -30...200 1,5 11,4 x 13,0 7,9 25 27 0,7 25 0,4 0,35 0,27 0,16 -30...200 1,5 11,4 x 13,0 7,9 25 20 0,2 17 0,18 0,35 0,27 0,16

Dimensions WxDxH (inch) 13,8 x 22,1 x 16,9 13,8 x 22,1 x 16,9 13,8 x 22,1 x 16,9 13,8 x 22,1 x 16,9 13,8 x 21,9 x 24,2 13,8 x 21,9 x 24,2 13,8 x 21,9 x 24,2 13,8 x 21,9 x 24,2

Cat.No.

G

Power Supply

2009.0004.01 2009.0013.99 2010.0004.01 2010.0012.99 2011.0004.01 2011.0011.99 2012.0004.01 2012.0011.99

2 2 2 2 2 2 2 2

115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz 115 V, 1~ 60 Hz

All units use natural refrigerant as standard

31


Baths and Circulators

Cooling Bath Circulators Huber cooling bath circulators perform safe and repeatable heating and cooling tasks in the lab. 22 models covering the range -90 °C to +200 °C with a selection of heating and cooling powers are available with air or water cooling (w). Natural refrigerants for environmentally friendly operation are available on request. A powerful variable speed pressure/suction pump allows the thermoregulation of objects directly in the bath or can be used to control external applications. The pump speed is stepless and when used in combination with an optional pressure sensor the maximum pressure can be controlled. VPC (Variable Pressure Control) ensures the best circulation and protects delicate glass apparatus from breakage caused by overpressure.

calibration insert ensures an even temperature distribution with a temperature stability of +/-0,01 K. All models have Active Cooling Control for cooling power control at the maximum working temperature and an automatic cooling power regulation for energy saving operation and reduced heat dissipation into the lab. Depending on the model carry handles or castors are fitted for easy transportation. The drain is located on the front of the unit to enable simple drainage of the bath. The cover plate is thermoregulated to avoid condensation. All models have the Pilot ONE with Plug & Play technology which can be simply swapped in the event of a service.

Small volume and high heating and cooling powers result in the shortest heating and cooling rates. Optional displacement inserts reduce the bath volume by half increasing this effect. Additionally the bath surface area is reduced, lowering moisture absorption. The optional calibration insert allows all Huber cooling circulators to be used as calibration baths. The

| CC®-405 |

Model

CC®-405 CC®-405w CC®-410 CC®-410wl CC®-415 CC®-415wl

Working Temperature Range (°C) - 40...200 - 40...200 - 45...200 - 45...200 - 40...200 - 40...200

* with displacement insert

32

www.huber-usa.com

Bath Heating Pump Data Volume Depth Power max. Pressure max. Suction (ltr) (inch) (kW) (l/min) (bar) (l/min) (bar) 5 5,9 1,6 33 0,7 22 0,4 5 5,9 1,6 33 0,7 22 0,4 22/8,5* 7,9 2,45 33 0,7 22 0,4 22/8,5* 7,9 2,4 33 0,7 22 0,4 5 5,9 1,6 33 0,7 22 0,4 5 5,9 1,6 33 0,7 22 0,4

Option: natural refrigerant available on request

100 0,7 0,7 0,8 0,8 1,2 1,2

Cooling Power (kW) at (°C) 20 0 -20 -30 0,7 0,7 0,45 0,18 0,7 0,7 0,45 0,18 0,8 0,8 0,5 0,15 0,8 0,8 0,5 0,15 1,2 1,0 0,6 0,2 1,2 1,0 0,6 0,2

Temperature Stability to DIN 12876: 0,02 K

-40 0,03 0,03 0,1 0,1 0,05 0,05

Cat.No.

G

Power Supply

2017.0003.01 2017.0004.01 2019.0006.01 2019.0002.01 2018.0007.01 2018.0009.01

2 2 2 3 2 3

208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz


Models | Compatible Control

| CC®-505 | | CC®-820w | Model

CC®-505 CC®-505wl CC®-508 CC®-508w CC®-510 CC®-510w CC®-515 CC®-515w CC®-520w CC®-525w CC®-805 CC®-820 CC®-820w CC®-902 CC®-905 CC®-905w CC®-906w

Working Temp. Range (°C) -50...200 -50...200 -55...200 -55...200 -50...200 -50...200 -55...200 -55...200 -55...200 -55...100 -80...100 -80...100 -80...100 -90...200 -90...200 -90...200 -90...200

* with displacement insert

1

Bath Heating Pump Data Volume Depth Power max. Pressure max. Suction (ltr) (inch) (kW) (l/min) (bar) (l/min) (bar) 5 5,9 1,6 33 0,7 22 0,4 5 5,9 1,6 33 0,7 22 0,4 5 6,3 2,45 33 0,7 22 0,4 5 6,3 2,45 33 0,7 22 0,4 26/15* 7,9 1,65 31 0,6 24 0,35 18/11* 7,9 1,65 31 0,6 24 0,35 26/15* 7,9 3,6 31 0,6 24 0,35 18/11* 7,9 3,6 31 0,6 24 0,35 17/10* 7,9 3,6 31 0,6 24 0,35 17/10* 7,9 3,6 31 0,6 24 0,35 5 5,9 1,5 33 0,7 22 0,4 17/10* 7,9 3,6 31 0,6 24 0,35 17/10* 7,9 3,6 31 0,6 24 0,35 5 5,9 1,8 33 0,7 22 0,4 26/15* 7,9 3,6 31 0,6 24 0,35 26/15* 7,9 3,0 31 0,6 24 0,35 30/19* 7,9 3,0 31 0,6 24 0,35

208 V option available

Function version available by E-grade®

Cooling Power (kW) at (°C) 100 20 0 -20 -40 1,2 1,2 1,0 0,6 0,15 1,2 1,2 1,0 0,6 0,15 1,5 1,5 1,5 1,0 0,3 1,5 1,5 1,5 1,0 0,3 2,1 2,1 2,1 1,0 0,4 2,4 2,4 2,4 1,0 0,4 3,3 3,3 3,3 1,6 0,6 3,3 3,3 3,3 1,6 0,6 5,0 5,0 5,0 3,0 1,5 7,0 7,0 5,0 3,0 1,5 0,5 0,5 0,5 0,4 0,3 1,2 1,2 1,2 1,1 0,9 1,2 1,2 1,2 1,1 0,9 1,2 1,2 1,2 1,1 0,9 2,0 2,0 2,0 1,9 1,7 2,0 2,0 2,0 1,9 1,7 3,0 3,0 3,0 2,8 2,4

Option: natural refrigerant available on request

Cat.No.

G

Power Supply

2018.0010.01 2018.0011.01 2018.0014.01 2018.0015.01 2020.0011.01 2020.0005.01 2021.0002.01 2020.0006.01 2022.0002.01 2023.0002.01 2024.0002.01 2025.0003.01 2025.0004.01 2026.0006.01 2027.0003.01 2027.0004.01 2036.0003.01

2 3 2 2 2 2 2 2 3 3 2 3 3 3 3 3 3

208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 460 V, 3~ 60 Hz1 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 208 V, 2~ 60 Hz 208 V, 3~ 60 Hz 208 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz 460 V, 3~ 60 Hz

Temperature Stability to DIN 12876: 0,02 K

33


Accelerated Forced ageing test • Calibration

Beer Force-AgeingTest Bath We offer a special air cooled circulator for the beer force-ageing-test. It is equipped with a programmer for the change between 0  °C / +40 °C and 0  °C / +60 °C in a 24 hour cycle. Casings and bath parts are made of stainless steel.

| BFT®5 |

Model

BFT®5

Working Temperature Range (°C) -40...80

Bath Opening W x D (inch) 13,8 x 16,1

Bath Depth (inch) 10,6

Heating Power (kW) 2,0

Cooling Power at 20°C (kW) 1,2

Dimensions WxDxH (inch) 18,1 x 28,0 x 35,9

Cat.No.

G

2041.0002.01

Power Supply

3 208 V, 2~ 60 Hz

Safety class III/FL

High Precision Calibration Calibration baths are used in quality management departments of industry and research. The modular concept based on the combination of a calibration bath with a Unistat, which dictates the temperature range and speed of temperature change. The calibration space is freely accessible and symmetrical. The upper edge is designed to allow exact reading of the temperature measured by glass thermometers and also offers a tight seal for the customer specific bath lid. Special calibration software in the circulator and the self-optimising controller with TAC technology mean short times between the different calibration temperatures. The calibration space of the baths can be customised to suit specific customer requirements. Advantages K Highest temperature stability up to ± 0,002 K K Temperature homogeneity better than ± 0,01 K K External overflow vessel K 5-point calibration of the control sensor

Flexible solutions for calibration in production Cal 700 – Calibration bath for measurement and control sensors

Accessories

The insulated stainless steel or PTFE bath covers allow for individual data recordings for sensors and thermometers, etc. We can custom design and manufacture the covers to your specifications (additional cost).

Temperature Range

Cat. No.

G

6367 6365

1 1

(°C) Bath Covers stainless steel* Bath Covers PTFE*

-100...300 -100...200

* Additional cost for holes

Model

Cal 700

Temperature Range (°C)

Pump Connection

Dimensions WxDxH (inch)

Opening (inch)

Bath Depth (inch)

Volume (ltr)

-100...300

M30x1,5

11,8 (17,3*) x 11,8 x 22,3

Ø4,6

15,1

7,0

* with external overflow vessel (5,5 inch)

34

www.huber-usa.com

Cat.No.

G

9623

3


Models | Hotbox • Heat Transfer Station

Hotbox The Hotbox is a heating circulator with Pilot ONE for thermoregulation of externally open applications. With its compact form the Hotbox is ideal for installation in production systems. The Hotbox has a stainless steel pump and adjustable over temperature protection complying with DIN 12876.

| Application example |

Model

HB45 HB60 HB120

Working Temperature Range (°C) 45...250 60...250 60...250

Connection M24x1,5 M30x1,5 M30x1,5

Pump Flow Rate (l/min) 55 90 100

| HB120 |

Heating Power (kW) 3,0 6,0 12,0

max. Pressure (bar) 0,9 2,5 2,5

Dimensions WxDxH (inch) 7,3 x 17,3 x 15,9 12,7 x 17,8 x 19,6 12,7 x 17,8 x 19,6

Cat.No.

2030.0002.01 2031.0006.01 2031.0007.01

G

Power Supply

3 208 V, 2~ 60 Hz 3 460 V, 3~ 60 Hz 3 460 V, 3~ 60 Hz

Heat Transfer Station (HTS) The HTS has no mechanical refrigeration but is fitted with a circulation pump, a plate heat exchanger and the Pilot ONE controller*. This compact circulator provides low cost cooling with a predictably stable pressure and flow to the application. As no mechanical refrigeration system is fitted (compressor etc.), the machine is silent, efficient and energy saving. It offers an economic alternative to standard circulators when a chilled water supply is already available. The HTS heat exchanger is suited for temperature control of bio reactors, condensers, rotary evaporators, vapour traps etc. Advantages: Models HTS PS3-PS15 K Efficient circulation pump K Pilot ONE controller K RS232 interface K Pt100 external sensor connection K Efficient thermal transfer K Low cooling water usage K Application protection with cooling stage separation

Model

HTS PS11 HTS PS3 HTS PS5 HTS PS6 HTS PS15 1 4

Operating Temperature Range (°C) (5)...(80)2 (3)...(95)2 (3)...(95)2 (3)...(95)2 (3)...(95)2

| HTS PS5 |

*Model HTS PS1 This model includes the heat exchanger system, but is not equipped with the Pilot ONE controller. This unit is suitable for less demanding applications.

Pump Cooling Power3 Heating Power Flow Rate max. Pressure at 20°C OPTIONAL (l/min) (bar) (kW) (max. kW)4 8 0,2 0,6 – 33 0,7 3,0 2,0 25 2,5 5,0 2,0 25 2,5 6,0 10,0 25 2,5 15,0 10,0

2 air cooled Auxiliary cooling/heating device required (see glossary „Working Temperature Range“) Optionally available on request with heating and over temperature protection

3

Dimensions WxDxH (inch) 11,0 x 16,8 x 16,3 11,0 x 19,3 x 16,3 11,0 x 19,3 x 16,3 15,8 x 19,3 x 20,8 15,8 x 19,3 x 20,8

Cat.No.

G

Power Supply

3011.0013.99 3011.0014.01 3011.0015.01 3011.0016.01 3011.0017.01

2 3 3 3 4

208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz 208 V, 2~ 60 Hz

Cooling power data measured with cooling water-inlet temperature of 10 °C and 2 bar

35


Reliable, environmentally friendly and best value for money:

Thermoregulation from Huber Quality Made in Germany

Best value for money

Unique Plug & Play

Case studies for performance comparison

e

de

Gra Proven technology

Worldwide Sales & Services

Accurate information according to DIN 12876

Safe investment due to E-grade function

Maximum safety for operator and application

Environmentally friendly with natural refrigerant

Connections for USB and network

Models for all applications

Time saving heat-up and cool-down times

Easy-to-use operation

State of the art technology guarantees highest precision

Free-of-charge warranty extension

More information at:

www.huber-usa.com Main Number: 1-919-674-4266 Toll free: 1-800-726-4877 Fax: 1-919-400-4543 info@huber-usa.com ¡ www.huber-usa.com

US_56765_01/2015

Huber USA Inc. 100 Centrewest Ct. Suite A Cary, NC 27513


Huber Product Overview US