Issuu on Google+

TM

Superior Indoor Air Quality For Your Family


Comfort From Floor to Ceiling, Sa With Hi-Velocity Systems , It’s TM

Why let your hot water just sit around, put it to work to heat your house, and save on your heating bills!

Third Party Components Easily Added

• Humidifiers • HRV/ERV’s • New! The Hi-Velocity Air Purification System - for unsurpassed Indoor Air Quality. See our website for details!

Programmable Energy Smart Motors

• Hi-Efficiency, reduce operating costs up to 50% • Automatic Voltage & Frequency Recognition 110 / 230 volt, 50 / 60 Cycle • Programmable variable frequency motor, utilizing mass flow technology to supply 1.5 to 5 tons (5.3 to 17.6 Kw) air flow • 6 independent speeds 1. Hi-Cooling 2. Low-Cooling 3. Dehumidification 4. Hi-Heating 5. Low-Heating 6. Constant air flow • Zoning Friendly

Single Side Access Fan Coils

• Cooling capacities ranging from: 1.5 to 5 tons (5.3 to 17.6 Kw) • Heating capacities up to: 140,000 btuh (41 Kw) • Optional heating coil simply slides in place • Comes pre-wired for heating, cooling, dehum ventilation so no additional controls are neede


atisfaction From Room To Room. Not Just A Dream. It’s Reality. The modern solution for all of your Heating, Cooling and IAQ needs.

Improved Indoor Air Quality

Installs:

• Draft free heating and cooling

Vertical Horizontal Counter-flow

midification and ed

• Even temperatures in every room • Constant flow air circulation helps eliminate dust

Flexibility in Vent Locations Flexible 2” and HE Branch Duct

Means less custom sheet metal work and the ability to meet the most complex architectural designs. Our HE Duct has been designed as a direct alternative for two 2” flex duct.

Vents can be installed in floors, ceilings or walls. Many more designs to choose from! Manufactured by


For All of your Heating, Cooling and IAQ Needs Model

HE-50/51

HE - 70/71

HE - 100/101

6 Row/10 FPI

6 Row/10 FPI

6 Row/10 FPI

59,400 54,500 49,600 44,600 39,700 34,700 29,700 24,800 20,100

89,200 81,800 74,400 67,100 59,700 51,800 44,700 37,400 30,300

134,000 122,900 111,800 100,700 89,700 78,400 67,100 56,200 45,500

5 3 470

7 6.5 700

10 6.8 1120

Hot Water Heating Coil Type Max. BTUH @ 190° E.W.T Max. BTUH @ 180° E.W.T Max. BTUH @ 170° E.W.T Max. BTUH @ 160° E.W.T Max. BTUH @ 150° E.W.T Max. BTUH @ 140° E.W.T Max. BTUH @ 130° E.W.T Max. BTUH @ 120° E.W.T Max. BTUH @ 110° E.W.T GPM Flow ratings Pressure Drop FT. H2O CFM @ 68°F E.A.T

Chilled Water Cooling Coil Type (WCM Modules in Cooling Mode)

6 Row/10 FPI Total Sensible

Max. BTUH @ 48°F E.W.T. Max. BTUH @ 46°F E.W.T. Max. BTUH @ 44°F E.W.T. Max. BTUH @ 42°F E.W.T. Max. BTUH @ 40°F E.W.T.

19,300 20,900 22,600 24,200 25,800

(WCM Modules in Heating Mode) Max. BTUH @ 150° E.W.T Max. BTUH @ 140° E.W.T Max. BTUH @ 130° E.W.T Max. BTUH @ 120° E.W.T Max. BTUH @ 110° E.W.T. GPM Flow ratings Pressure Drop FT. H2O

13,700 14,200 14,900 15,700 16,300

6 Row/10 FPI Total Sensible 27,000 29,400 31,800 34,000 36,400

6 Row/10 FPI Total Sensible

19,200 20,000 21,000 21,800 23,000

42,100 45,800 49,500 53,200 56,800

30,300 32,100 33,700 35,100 36,400

Total 39,700 34,700 29,700 24,800 20,100

Total 59,700 51,800 44,700 37,400 30,300

Total 89,700 78,400 67,100 56,200 45,500

5 3

7 6.5

10 6.8

1.5 - 2.0

2.5 - 3.0

3.5 - 5.0

5 - 15 Kw

5 - 18 Kw

5 - 23 Kw

Refrigerant Cooling (RPM Modules) BTUH Refrigerant TX Cooling (tons)

Electrical Heating Kilowatt Range

11 5 / 2 3 0 / 1 / 5 0 / 6 0 F. L . A . 8 a m p

Voltage Max Rated C.F.M. Horse Power/Watts R.P.M. Integral Surge and Fuse System Supply Air Size Supply Maximum Length(1) Return Size Needed Minimum Outlets(2) Maximum Outlets

520 3/4 - 310 Variable Yes 8” round 70’ 12” (113 in2)

770 3/4 - 530 Variable Yes 8” round 80’ 12” (113 in2)

1260 3/4 - 720 Variable Yes 10” round 100’ 14” (154 in2)

12 24

20 32

28 52

Smaller condensers may be matched to the fan coil when needed (match TXV to condenser size.) Maximum length is from the unit to the supply end run cap. More than one run per unit is allowable. (3) Minimum of 8 full outlets per ton of cooling needed. (1)