Product Catalogue 2014 FlexField


Contents FlexField The Flexfield Concept............................................... 3 Racks and Subracks.................................................. 5 DDF Modules and Accessories.................................. 8 Ethernet Modules and Accessories.......................... 16 ODF Modules and Accessories................................. 19

2


The FlexField Concept FlexField is the Most Flexible Cross Connection System. It handles coax-, pair- and opto cables. It meets telecom standard G.703. It handles data – Ethernet Cat 6. It is built on modules – fits small as well as big systems.

A variety of cables and connectors

The module is the basic unit. There are modules to handle a variety of cables and connectors.

A Mix of Modules for Big or Small Installations at a Low Cost Modules are hosted in the subrack. Five sizes of subracks are available. Different types of modules – for different connectors/cables can be in the same subrack. Start with the number of modules you need and then just partly fill the subrack. Then add modules as needed.

3


The FlexField Concept Problem Free Access to All Connectors with Cabinets to the Wall

Due to the patented cable management in the module there is always access to all connections. The cable management creates a built in cable slack that allows the module to always be extracted a minimum of 30 cm from it’s original position – even at full installation. The fiber optic modules have additional movement – they can be extracted 1.5 m. All terminations are accessible from front. This means that cabinets can be placed tightly side by side against a wall.

19” and ETSI Racks/Cabinets - All Types The subracks have mounting ears that are adjustable in width and depth.

Safe Maintenance Quick Access No stress on the connectors when moving the modules, the cables are mechanically fixed to the modules.

Patch Cords Well Protected Patch cords are strictly managed and well protected. The patch cords from each module enter through their own slot into the cable shelf. The cable shelf has a foldable front allowing quick access.

4


Racks and Subracks

High Density Service Friendly Patch Cord Management Rack Designed for large amount of patch cords. Patch cord crossing between racks is possible at the top. No need for threading patch cords. All passages are open. Bending radius min. 30 mm is guaranteed. At the top of the rack there is a built in cable duct. This replaces overhead mounted cable duct. The rack has surface treatment with very good electrical conductivity. The rack has a grounding rail for 10 connections.

Subracks The subrack comes in 5 sizes. Number of modules 1–10 pcs, height 1–5u. All subracks give front access to all connection points, which makes this system service friendly.

5


Racks and Subracks Flexfield Rack 2000 Part no. 5211 Rack with 19” profiles Height 2050, width 600, depth 400 Inside height 42u Cable management handles up to 4000 patch cords. No need for threading patch cords. All passages ore open. Bending radius min. 30 mm is guaranteed. Surface treatment with very good electrical conductivity. Grounding rail for 10 connections. When 2 racks are positioned side by side with a center distance of 800 mm there is a storage for patch cord overlength. This can handle up to 4 meters overlength.

Flexfield Subrack 200 Part no. 5087/20 Capacity 10 modules Fits in ETSI and 19” rack/cabinet Adjustable mounting ears Distance front – rack mounting point 30 alt. 80 mm Dimensions HxD 199(5u)x270 mm Signing strip

6


Racks and Subracks Flexfield Subrack 45 Part no. 5087/13 Capacity 2 modules Fits in ETSI and 19” rack/cabinet Adjustable mounting ears Distance front – rack mounting point 30 alt. 80 mm Dimensions HxD 44(1u)x270 mm Signing strip

Flexfield Subrack 133 Part no. 5263 Capacity 10 modules Fits in ETSI and 19” rack/cabinet Adjustable mounting ears Distance front – rack mounting point 30 alt. 80 mm Dimensions HxD 133(3u)x195 mm Possibility to use bending radius limiter

Flexfield Wall Mount Box Part no. 5087/30 Capacity 1 module Dimensions HxWxD: 190x130x45 mm

7


DDF Modules and Accessories

High Packing Density Service Friendly

More than 400 coax systems or more than 800 pair cable systems can be installed in one rack or cabinet, to meet high packing density. All connections will remain accesible and cross connection work can easily be performed.

Transmission Requirements - G.703 All signals pass through multi-layer impedance controlled PCB’s and connectors of correct impedance. This gives good signal integrity and the transmission requirements in G.703 are met. The SWR budget of your link will not be ruined by FlexField.

EMC All PCB’s have a signal at the inner layers and shielding at the outer layers. The cable shields are terminated at low impedance. This results in low emission and high immunity. EMC-standards like directives 89/336/EEC, 92/331 EEC are fulfilled.

Surge Pulse In some telecom applications there is a 500V surge pulse requirement. All FlexField modules fulfill this. They are tested according to IEC 61000-4-5.

8


DDF Modules and Accessories FlexField Module RJ-IDC Part no. 5100/01 Pair cable, 2 Mbit/s, E1/T1/J1 8 systems Front: RJ45/48 Inside: IDC termination, 16 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField Module RJ-IDC Monitor Part no. 5100/27 Pair cable, 2 Mbit/s, E1/T1/J1 4 systems with monitor ports Front: RJ45/48, RJ45/48 25dB monitor ports Inside: IDC termination, 8 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField Module RJ-RJ Part no. 5100/02 Pair cable, 2 Mbit/s, E1/T1/J1 8 systems Front: RJ45/48 Inside: RJ45/48

FlexField Module RJ-RJ Monitor Part no. 5100/26 Pair cable, 2 Mbit/s, E1/T1/J1 4 systems with monitor ports Front: RJ45/48, RJ45/48 25dB monitor ports Inside: RJ45/48

9


DDF Modules and Accessories FlexField Module IDC-IDC Part no. 5100/15 Pair cable, 2 Mbit/s, E1/T1/J1 8 systems IDC termintion, 16+16 pair Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField G.703 Pair Cable Monitor Cable Part no. 3408/P100/K100 Suitable for modules 5100/26, 5100/27. To be used when the test instrument has BNC 75Ω interface. Length 2 m

FlexField G.703 Coax Monitor Cable Part no. 3102/200 Suitable for modules 5100/09, 5100/31, 5100/32, 5100/40, 5100/41, 5100/43 To be used when the test instrument has BNC 75Ω interface. Length 2 m

FlexField Module 1,6/5,6 - 1,6/5,6 Part no. 5100/04 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems Front: 1,6/5,6 Jack Inside: 1,6/5,6 Jack

10


DDF Modules and Accessories FlexField Module 1,6/5,6 - 1,6/5,6 Monitor Part no. 5100/31 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems with monitor ports Front: 1,6/5,6 Jack, M4 Jack 25dB monitor ports Inside: 1,6/5,6 Jack

FlexField Module M4-M4 Part no. 5100/06 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems Front: M4 Jack Inside: M4 Jack

FlexField Module M4-M4 monitor Part no. 5100/32 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems with monitor ports Front: M4 Jack, M4 Jack 25dB monitor ports Inside: M4 Jack

FlexField Module BNC-BNC Part no. 5100/08 Coax 75Ω 2–270 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1/video 4 systems Front: BNC Jack Inside: BNC Jack

11


DDF Modules and Accessories FlexField Module BNC-BNC Monitor Part no. 5100/09 Coax 75Ω 2–270 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1/video 3 systems with monitor ports Front: BNC Jack, M4 Jack 25dB monitor ports Inside: BNC Jack

FlexField Module 1,0/2,3 - 1,0/2,3 Part no. 5100/34 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems Front: 1,0/2,3 Jack Inside: 1,0/2,3 Jack

FlexField Module 1,0/2,3 - 1,0/2,3 Monitor Part no. 5100/35 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems with monitor ports Front: 1,0/2,3 Jack, M4 Jack 25 dB monitor ports Inside: 1,0/2,3 Jack.

FlexField Module BT43-BT43 (SMB 75Ω) Part no. 5100/42 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems Front: BT43 Jack Inside: BT43 Jack

12


DDF Modules and Accessories FlexField Module BT43-BT43 Monitor (SMB 75Ω) Part no. 5100/43 Coax 75Ω 2–155 Mbit/s, E1/T1/J1/E3/T3/J3/STM-1 4 systems with monitor ports Front: BT43 Jack, M4 Jack 25dB monitor ports Inside: BT43 Jack

FlexField Module 1,6/5,6 - IDC Balun Part no. 5100/10 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: 1,6/5,6 Jack Inside: IDC termination, 8 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField Module 1,6/5,6 - IDC Balun Monitor Part no. 5100/41 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: 1,6/5,6 Jack, M4 Jack 25 dB monitor ports Inside: IDC termination, 8 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField Module M4 - IDC Balun Part no. 5100/11 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: M4 Jack Inside: IDC termination, 8 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

13


DDF Modules and Accessories FlexField Module M4 - IDC Balun Monitor Part no. 5100/40 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: M4 Jack, M4 Jack 25 dB monitor ports Inside: IDC termination, 8 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField Module BNC-IDC Balun Part no. 5100/12 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: BNC – Jack Inside: IDC termination, 8 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm Low impedance termination of shield

FlexField Module RJ-M4 Balun Part no. 5100/23 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: RJ45/48 Inside: M4 Jack

FlexField Module RJ-BNC Balun Part no. 5100/24 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: RJ45/48 Inside: BNC Jack

14


DDF Modules and Accessories FlexField Module RJ - 1,6/5,6 Balun Part no. 5100/25 Pair cable – coax 75Ω 2 Mbit/s, E1/T1/J1 4 systems Front: RJ45/48 Inside: 1,6/5,6 Jack

15


Ethernet Modules and Accessories

The Patch Panel

For high density performance, Memoteknik offer more than 800 systems in a standard rack. It is a service friendly system, as the patch cords are strictly organized and all connections will be accesible so cross-connection work can easily be performed. Choose between modules for Cat5e or Cat6, STP or UTP. You may also terminate the fiber optic riser cable and the PABX in the same patch panel. For fiber optics see section ODF.

The Work Area Outlet 8 RJ45 for 1–4 workplaces. Choose between modules for Cat5e or Cat6, STP or UTP.

DC-Current in Cable Shield In STP cabling there is always risk for unwanted DC-current in the shield, due to varying ground potentials in the building. This causes a current to flow in the cable shields and this may give lower capacity in your network. To avoid this there is a module with built in dc-barrier, 5100/17.

16


Ethernet Modules and Accessories FlexField Module RJ - IDC Ethernet STP/UTP Cat5e Part no. 5100/16 Ethernet 10/100 shielded and unshielded twisted pair 8 systems Front: RJ45 Inside: IDC termination Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm

FlexField Module RJ - RJ Ethernet STP/UTP Cat5e Part no. 5100/02 Ethernet 10/100 shielded and unshielded twisted pair 8 systems Front: RJ45 Inside: RJ45

FlexField Module RJ - JDC Ethernet UTP Cat6 Part no. 5100/38 Ethernet 10/100 gigabit ethernet unshielded twisted pair 6 systems Front: RJ45 Inside: IDC termination Conductor: 0.4–0.63 mm Isolation: max 1,27 mm

17


Ethernet Modules and Accessories FlexField Module RJ - IDC Ethernet STP Cat6 Part no. 5100/39 Ethernet 10/100 gigabit ethernet shielded twisted pair 6 systems Front: RJ45 Inside: IDC termination Conductor: 0.4–0.63 mm Isolation: max 1,27 mm

FlexField Module RJ - IDC Ethernet STP Cat6 with DC-barrier Part no. 5100/17 Equipped with DC-barrier – to stop flow of DC-current in cable shields. EMC safe design Ethernet 10/100/gigabit ethernet shielded twisted pair 4 systems Front: RJ45 Inside: IDC termination Conductor: 0.4–0.63 mm Isolation: 0.7­–1.1 mm

FlexField Module RJ - IDC Ethernet UTP Cat3 Part no. 5100/36 Telephone signals 64 kbit/s For termination of PABX Unshielded twisted pair 10 lines Front: RJ45 Inside: IDC termination, 20 pairs Conductor: 0.4–0.63 mm Isolation: 0.7–1.1 mm

18


ODF Modules and Accessories

ODF for Trunk Networks, Fibre to the x, LAN

Thanks to its modular design FlexField makes an ODF for a variety of applications. The FlexField fiber optic module handles 12 fibres. It holds splices, both single fiber and ribbon fiber and it holds fanouts. Break-out cable and micro ducts also fit. Versions with SC adapters and FC adapters are available. An ODF from twelve to thousands of fibers can be built.

Splicing Splices of various sizes are accepted. Defined positions give good overview. Minimum bending radius is guaranteed.

19


ODF Modules and Accessories Cleaning The front with the adapters can be pulled out. This makes it possible to clean the inner connectors.

Service Friendly The fibers enter the module through a flexible tube. This is ength of 1.5 meters. This gives the benefit that the splicing work can be done with the module conviniently placed on a working bench, out of the cabinet. When inserting the module in the cabinet, the flexible tube is rolled up and stored in the module.

Joint The cable is coupled to the flexible tube by a joint. The image shows Joint 48 handling on the left side, handling a cable with maximum 48 fibers.

Break Out Cable There is also a module for cables without splices, which has a low bending radius – which allows it to be brought directly into the module: break out cable; patch cord cable. No joint is used.

20


ODF Modules and Accessories FlexField Module Break out SC Part no. 5100/136 For cables with connectors: break out cable; patch cord cables. Cable bending radius maximum 45 mm. 12 fibers. SC adapters of SM quality, 6x2.

FlexField Module splicing SC Part no. 5100/296 For splicing of ribbon fiber or single fiber. Length of splice maximum 45 mm. 12 fibers. The cable is connected to this module using joint 48. SC adapters of SM quality, 6x2.

FlexField Module Splicing SC, Preconnected Part no. 5100/306 For splicing of ribbon fiber or single fiber. Length of splice maximum 45 mm. Preconnected with 12 pcs of pigtails, SM 10/125 UPC. 12 fibers. The cable is connected to this module using joint 48. SC adapters of SM quality, 6x2.

FlexField Module Break Out FC/PC Part no. 5100/37 For cables without splices and having low bending radius, which allows it to be brought directly into the module: break out cable; patch cord cable. 8 fibers. FC/PC adapters of SM quality, 8x1.

21


ODF Modules and Accessories FlexField Pigtail SM 10/125 SC/UPC Part no. 4P021000/01/0100 Single fiber 10/125. Length 1 m. Diameter 0.9 mm Connector SC UPC.

FlexField Pigtail MM 50/125 SC Part no. 4P101000/01/0100 Single fiber 50/125. Length 1 m. Diameter 0.9 mm Connector SC.

FlexField Pigtail MM 62.5/125 SC Part no. 4P201000/01/0100 Single fiber 62.5/125. Length 1 m. Diameter 0.9 mm Connector SC.

FlexField Module Patch Cord Storage Shelf Part no. 5100/14 Storage of patch cord overlength. 12x5 m 2 mm cable can be stored. Occupies the space of 2 modules in the sub rack. Dimension W 80 mm.

22


ODF Modules and Accessories FlexField Module Patch Cord Storage Bobbin Part no. 5100/19 Storage of excess patch cord. 12x3 m 2 mm cable can be stored. Occupies the space of 1 module in the subrack. Dimension W 40 mm. Bending radius min 30 is mechanically controlled.

Bending Radius Limiter 1u Part no. 5238 1 pair. Fits in subrack 45-3. Dimensions H 45 mm (1u). Can be mounted and unmounted with subrack mounted in the rack. Protects patch cords from sharp bending. Quick mounting.

Bending Radius Limiter 2u Part no. 5239 1 pair. Fits in subrack 133. Dimensions H 88 mm (2u). Can be mounted and unmounted with subrack mounted in the rack. Protects patch cords from sharp bending. Quick mounting.

FlexField Joint 48 Part no. 5195 For joining a cable containing maximum 48 fibers to maximum 4 Modules 5100/296 or 5100/306.

23


Memoteknik - Partnership makes perfect™ Memoteknik is a quick thinking, proactive and solution oriented company. We help telcom companies to develop mechanical solutions that are more cost effective, efficient and better than ever before. We have friends and partners throughout the world to help us make these ideas into reality. Our headquarters and cultural background come from northern Sweden in a little city next to the polar circle called Skellefteå. This gives us a sense of stability and loyalty towards our friends and partners.

A Part of Hexatronic Group Memoteknik AB is a part of Hexatronic which is an innovative Swedish technology group, specializing in fiber communications. The Group provides products and solutions for the fiber optic network and together, the six independent, entrepreneurial companies offer a full range of passive infrastructure. We combine our large corporate stability and resources with small company flexibility and speed. Our customers are companies within the telecommunications industry such as communications and telecom suppliers, operators and network owners. The other companies within The Group are Hexatronic Cables & Interconnect Systems in Hudiksvall, Hexatronic Elektronik & Data in Gothenburg, The Blue Shift and Proximion in Stockholm and TD Fiberoptik in Örebro.

For more information: www.hexatronicgroup.com

Memoteknik AB, Verkstadsvägen 1, 931 61 Skellefteå Tel +46 (0)910 71 16 80 Fax +46 (0)910-853 40 info@memoteknik.com order@memoteknik.com

linkedin.hexatronicpartners.se

twitter.hexatronicpartners.se

youtube.hexatronicpartners.se

issuu.hexatronicpartners.se nr © Memoteknik AB 2014