Page 1

ProClimate

H VAC & Dehumi d i fi cati o n S o l uti o ns G ui d e

VOLUME 1.2


// Founded in 1965, Herc Rentals, formerly Hertz Equipment Rental Corporation, is one of the leading equipment rental suppliers in North America. Herc Rentals offers a broad portfolio of equipment across an extensive network of 280 company-operated branches, and recently expanded its ProSolutions™ line of products to better serve our customers. The new ProSolutions™ business provides specialty equipment coupled with technical expertise and full service onsite support to solve our customers’ toughest challenges. Our industry-specific expertise and solutions-based services complement our expanded lineup of portable power, climate control, site protection, and pumping equipment. Our mission is to help you work more efficiently, effectively, and safely - no matter the job or the environment.

NL

BC

MB

AB SK

QC

NB

ON

NS ME WA ND

VT

MT

MN NY

WI

OR

SD

ID

MI PA

WY IA

CA

IN

NE

UT

WV

MO

KS

NJ MD

OH

IL

NV CO

NH MA CT RI

DE

VA

KY NC TN

AZ

OK

NM

SC

AR MS

TX

AL

GA

LA

FL

HI

Classic Rentals Location

2

ProSolutionsTM Location

© 2016 Hertz Equipment Rental Corporation. Trade/service marks are the property of their respective owners. All rights reserved. The contents of this publication are protected by the United States copyright law.


ProClimate

Table of Contents 5 NEW INNOVATIONAL PRODUCTS 6 SPOT COOLERS 8 PACKAGED UNITS 11 HYBRID UNITS 12 INDUSTRIAL HIGH-STATIC AIR CONDITIONERS 15 AIR COOLED CHILLERS 16 CHILLED WATER AIR HANDLERS 18 DEHUMIDIFIERS 21 AIR QUALITY CONTROL 24 PORTABLE GENERATORS 25 RELATED PRODUCTS 26 ELECTRIC HEAT 28 INDIRECT FIRED 30 INLINE HEATERS 31 SELF-CONTAINED 33 DIRECT FIRED 35 INDUSTRIAL ELECTRIC 36 FLAMELESS 38 HYDRONIC SURFACE 39 APPLICATION GUIDE 40 RELATED PRODUCTS 41 ACCESSORIES 42 GLOSSARY 44 SIZING CALCULATIONS 45 CREDIT APPLICATION

3


Our branch locations are open Monday through Friday from 7:00 a.m. to 5:00 p.m., but knowledgeable members of the HERC ProSolutions™ team are available 24/7 assist you with quotes, reservations, rental delivery, and technical support.

// PROJECT CONSULTATION Before any equipment is recommended or specified, we will walk your site to truly understand your project or event needs, its environment and special considerations. Walking your site along-side your team will ensure we specify the right equipment, accessories and supporting service accessories.

// CUSTOMIZED SOLUTIONS A member of our Herc ProSolutions™ team will design a plan specific for your needs and application. We will review your needs, the environment and all the special considerations such as access, power, available space, sound and emission requirements, and more. We don’t just deliver equipment; we customize our offerings to suit the unique needs of every job and environment.

// SUPERVISED INSTALL AND REMOVAL Once your specialty equipment order is placed and en route, our trained professionals will be on site to make sure your equipment is set up properly and working as it should. If the parameters of the job or tools need to change, we’ll be there to respond immediately to ensure your schedules stay on track and all your needs are met.

// TECHNICAL SUPPORT Throughout your project, you may find yourself in need of a specialist due to changing conditions or scope of work. Help is a phone call away. We’ll be there for you during every phase of your project.

// 24/7 Our ProSolutions™ team is always open for business. We are fully equipped to solve your tough challenges, and stand ready to respond to intense time constraints or challenging site conditions. No matter what hours - day or night - we are ready to help you accomplish your mission-critical projects. We know that our solutions offerings to you are only as good as our ability to provide highly responsive service and support.


NEW PRODUCTS

NEW PRODUCTS

// NEW INNOVATIONAL PRODUCTS FROM HERC RENTALS NEW GROUND PROTECTION

Light-duty mats Medium-duty mats

Learn more about our ground protection products on PAGE 27 //

NEW PROLIGHTING

LED LIGHT TOWERS Easy to setup, operate and maintain, our light towers provide maximum power in a minimal footprint. Learn more about our new selection of light towers at HercRentals.com

NEW HYPO THERM PLASMA CUTTERS NEW BATTERY POWER Learn more about Gridless portable power solutions at HercRentals.com

HercRentals.com

Learn more about Hypo therm plasma cutters at HercRentals.com

5


SPOT COOLERS

SPOT COOLERS

SPOT COOLERS

Spot Coolers can be used in large or small areas for all of your cooling or heating needs. These units allow you to cool or heat targeted areas - representing substantial energy savings in comparison to central air.

Movincool // Office Pro 60 • 24/7 programmable operating modes • Provides 60,000 Btu/h of cool air, maximum spot cooling to just the room that needs it • No costly installation necessary, simply roll it in, plug it in, turn it on • Condensation pump included, pumps water to remote drain for uninterrupted operation • Operates automatically after-hours or during weekends with easy-to-use controls

Remediation & Cimate Control Trailer ProSolutions Remediation specializes in rental equipment and services related to restoration and drying equipment, emergency power and distribution, and climate and humidity control with a quick response and expert approach when it matters most.

6

Call 844-892-1734 for rates and reservations


SPOT COOLERS

SPOT COOLERS

Movincool // Climate Pro 12

Movincool // Climate Pro 18

Movincool // Classic 14

• Highest-performance unit in its class by actual measured output • High cooling capacity of 10,200 Btu/h (11,500 Btu/h ASHRAE Standard 128-2001) • High heating capacity of 9,900 Btu/h • Large, easy-to-read LCD display provides on-screen diagnostics, with step-by-step instructions to start, set up or restore operation.

• Highest-performance unit in its class by actual measured output • High cooling capacity of 14,600 Btu/h (16,800 Btu/h ASHRAE Standard 128-2001) • High heating capacity of 13,700 Btu/h • Large, easy-to-read LCD display provides onscreen diagnostics, with step-by-step instructions to start, set up or restore operation.

• Digital temperature control. Set the desired temperature and walk away. • Operates on standard 115v power. • Provides up to 13,200 Btu/hr of cool air. Maximum spot cooling to just the spot that needs it. • Handles temperatures up to 113°F. Provides cooling in the hottest environments.

HEATING + COOLING

Automatic computer cooling and drying making water damage restoration quick and easy. Many units available with heat.

Applications /

• Comfort cooling for workers

• Thermal protection

• Data centers

• Closet server rooms

MAKE

MODEL

COOLING CAPACITY

HEATING CAPACITY

VOLTAGE

DIMENSIONS (WDH)

WEIGHT

AMPS

CAT-CLASS

Movincool

Climate Pro 12

10,200 Btu/h

9,900 Btu/h

1 Phase, 115V

21 x 27 x 44 in

196 lbs.

11 AMPS

718-1102

Movincool

Climate Pro 18

14,600 Btu/h

13,700 Btu/h

1 Phase, 115V

21 x 27 x 49 in

214 lbs.

14 AMPS

718-1102

Movincool

Office Pro 60

60,000 Btu/h

N/A

1 Phase, 230V

30 x 52 x 64 in

623 lbs.

29 AMPS

718-1150

Movincool

Office Pro 63

60,000 Btu/h

N/A

3 Phase, 460V

30 x 52 x 64 in

705 lbs.

9.5 AMPS

718-1155

Movincool

Classic 14

13,200 Btu/h

N/A

1 Phase, 115V

19 x 26 x 41 in

166 lbs.

15 AMPS

718-1100

HercRentals.com

7


PACKAGED UNITS

PACKAGED UNITS

PACKAGED UNITS

General Purpose Packaged Units provide cooling, heating or dehumidification of recirculated air for both small and large applications. These units feature integrated temperature controls and convenient electrical / ductwork connections.

CAPS 5 TON NEMA7 // PPKH-5TD-0NN9KE-5B2-P1-G2CEUP

CAPS 5 TON GENERAL PURPOSE // PPKH-5TD-0NN20KE-5E5-P1-G2CEUP

• Constructed for use in Class 1 Division 2 hazardous environments • One (1) 20” outlet & one (1) 20” inlet air duct connections • Electrical heat (9 kW)

• One (1) 20” outlet & one (1) 20” inlet air duct connections • Electrical heat (20 kW) • 2,000 CFM @ 0.6” Total Static Pressure • Hot dipped galvanized structural skid / cage for lifting and stacking • Integrated foldable casters • Single point electrical connections • Hour meter, phase protection and integrated temperature controls • Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection

• NEMA 7 Rated: Designed to contain an internal

explosion without causing an external hazard

• 2,000 CFM @ 0.6” Total Static Pressure • Hot dipped galvanized structural skid / cage for lifting and stacking • Integrated foldable casters • Single point electrical connections • Hour meter, phase protection and integrated temperature controls

Applications /

Heating, cooling and dehumidification of recirculated air for the following markets;

• Petrochemical • Food processing

• Commercial buildings • Hospitals

• Manufacturing • Data centers

MAKE

MODEL

CFM

CAPACITY

HEATING CAPACITY

MOISTURE REMOVAL

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

CAPS

PPKH-5TD

2,000

5 Tons

20 kW

18 lbs./hr

460V

0.6" @ 2,000 CFM

6'6" x 4'4" x 5'

CAPS

PPKH-5TD

2,000

5 Tons

9 kW

18 lbs./hr

460V

0.6" @ 2,000 CFM

6'6" x 4'4" x 5'9"

8

• Film production • Pharmaceutical

NEMA RATING

CAT-CLASS

1,200 lbs.

4

718-1210

1,400 lbs.

7

718-1610

AMPS

Call 844-892-1734 for rates and reservations


PACKAGED UNITS

PACKAGED UNITS

CAPS 10 TON GENERAL PURPOSE // PPKH-10TD-0NN36KE-5E5-P2-G2CEUP

CAPS 25 TON GENERAL PURPOSE // PPKH-25TD-0NN72KE-5E5-P2-G2CEUP

• One (1) 20” outlet & one (1) 20” inlet air duct connections • Electrical heat (36 kW) • 4,000 CFM @ 2.2” Total Static Pressure • Hot dipped galvanized structural skid / cage for lifting and stacking • Fork truck compatible from all four (4) sides • Single point electrical connections • Hour meter, phase protection and integrated temperature controls • Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection

• Two (2) 20” outlet & two (2) 20” inlet air duct connections • Electrical heat (72 kW) • 10,000 CFM @ 2.7” Total Static Pressure • Hot dipped galvanized structural skid / cage for lifting and stacking • Fork truck compatible from all four (4) sides • Single point electrical connections • Hour meter, phase protection and integrated temperature controls • Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection

UNITED COOLAIR 5 TON AC WITH HEAT PUMP // PAC5N3ASAHP

UNITED COOLAIR 12 TON AC WITH HEAT // MACH145G3AS

• Heavy duty steel cabinet • Grab handles (one pair) • Condenser coil guard • 14” or 16” duct collars (1 supply, 1 return) • Insulated evaporator section • Electro-mechanical thermostat • Recessed control panel

• Powder coated HD steel cabinet • 14” duct collars (2 supply, 2 return) removable • 18” duct collars (Condenser air IN and OUT) • 8” swivel casters with brake • Condensate P-trap • Stainless steel drip pan w/ threaded drain conn. • Four-way forklift pod

MAKE

MODEL

CFM

CAPACITY

HEATING CAPACITY

MOISTURE REMOVAL

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PPKH-10TD

4,000

10 Tons

36 kW

-

460V

2.2' @ 4,000 CFM

8' 5" x 6' x 5' 1"

2,300 lbs.

4

718-1210

CAPS

PPKH-25TD

10,000

25 Tons

72 kW

82 lbs./hr

460V

2.7" @ 10,000 CFM

12' 8" x 8' 5" x 5' 4"

4,600 lbs.

4

718-1610

MAKE

MODEL

CFM

HEATING CAPACITY

COOLING CAPACITY

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

United CoolAir

PAC5N3ASAHP

2000

54,592 BTU

5 Ton

208/230-1-60

1.5" @ 2,000 CFM

54.5" x 67" x 29.5"

670 lbs.

718-1150

United CoolAir

MACH145G3AS

4000

102,360 BTU

12 Ton

208/230-3-60

1.5" @ 4,000 CFM

71" x 78" x 34.5"

1300 lbs.

718-1302

HercRentals.com

9


PACKAGED UNITS

VERTICAL PACKAGED UNITS

PACKAGED UNITS

Vertical Packaged Units are custom temperature control equipment for temporary or permanent applications. Whether cooling a tent or a building, our systems meet the most demanding expectations in unique environments.

CAPS 20 TON VERTICAL // PPKV-20TD-0NN72KE-5E5-P2-VG2CEUP • Dual stage heating & cooling circuits with hot gas bypass • 7,800 CFM @ 1.25” total static pressure • Electrical heat (72 kW) • Double deflection supply air grille • Easy access return air filter grille • User friendly safety service access • Integrated quad box power receptacle

Applications /

• Entertainment (TV/Movie) • Tent cooling

MAKE

MODEL

CFM

COOLING CAPACITY

HEATING CAPACITY

MOISTURE REMOVAL

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH) WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PPKV-20TD

8,000

20 tons

72 kW

95 lbs./hr

460V

1.25" @ 8,000 CFM

7' 7" x 3' x 8'

4

718-1525

10

2,600 lbs.

Call 844-892-1734 for rates and reservations


HYBRID UNITS

HYBRID UNITS

CAPS 40 TON // PPKH-40TD-0NN120KE-5E5-P2-VG2CEUP • Cooling • Heating • Dehumidification • 100% outside • 100% return air operation • Dual R410A refrigeration circuits • 120 kW staged electric heat and DH option • 14,000 CFM @ 4.25” Total Static Pressure

HYBRID UNITS: 1 UNIT, 5 FUNCTIONS

CAPS 60 TON // PPKH-60TD-0NN136KE-5E5-P2-VG2CEUP • Cooling • Heating • Dehumidification • 100% outside • 100% return air operation • Dual R410A refrigeration circuits with four stages of cooling • 136 kW staged electric heat and DH option • 20,000 CFM @ 4.25” Total Static Pressure

Applications /

Heating, cooling and dehumidification. 100% return or 100% outside air for the following markets;

• Petrochemical • Food processing • Commercial buildings

• Hospitals • Manufacturing • Data centers

• Film production • Pharmaceutical

MAKE

MODEL

CFM

COOLING CAPACITY

HEATING CAPACITY

MOISTURE REMOVAL

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PPKH-40TD

14,000

40 Tons

120 kW

146 lbs./hr

460V

4.25" @ 14,000 CFM

16' 5" x 7' 8" x 6' 7"

8,300

4

718-1830

CAPS

PPKH-60TD

20,000

60 Tons

136 kW

189 lbs./hr

460V

4.25" @ 20,000 CFM 20' x 8' 5" x 8' 5"

10,500

4

718-2030

HercRentals.com

11

HYBRID UNITS

Hybrid Units provide cooling, heating, dehumidification, 100% return air or 100% outside air operations. These units feature large cooling and heating capacities and VFD speed control high-static evaporator fans. User friendly temperature controls, convenient electrical / ductwork connections that offers flexible operations for a variety of different applications.


INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

Industrial High-static Air Conditioners provide cooling and dehumidification of return or outside air operations. These units feature large cooling capacity delivering large Delta T cooling and high-static evaporator fans. User friendly temperature controls, convenient electrical / ductwork connections that offers flexible operations for a variety of different applications. The unit’s construction features stainless steel cabinet, hot dipped galvanized lifting frame and corrosive protection on both the condenser and evaporator coils.

CAPS 20 TON NEMA4 // PPKH-20TD-0NN0NN-5E5-P2-S1CEUP • 40° Delta T cooling performance (95°F entering and 55°F leaving air) • High-Static Pressure – push air further without experiencing significant CFM loss • Industrial construction • DDC controls and service friendly • Entering / leaving air temperature controls • Rental ready construction, controls, safeties and duct connections • Hot dipped galvanized skid & cage • Stainless steel cabinet construction • NEMA 7 Rated: Designed to contain an internal

explosion without causing an external hazard

CAPS 20 TON NEMA7 // PPKH-20TD-0NN0NN-5B2-P2-S1CEUP

Applications /

Heating, cooling and dehumidification of return or outside air for the following markets;

• Petrochemical • Food processing • Commercial buildings

• Hospitals • Manufacturing • Data centers

• Film production • Pharmaceutical

MAKE

MODEL

CFM

CAPACITY

MOISTURE REMOVAL

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PPKH-20TD-GP

2,800

20 Tons

126 lbs./hr

460V

7.0" @ 2,800 CFM

8' 11" x 6' 7" x 7' 10"

4,500 lbs.

4

718-1500

CAPS

PPKH-20TD-XP

2,800

20 Tons

126 lbs./hr

460V

7.0" @ 2,800 CFM

8' 11" x 6' 7" x 7' 10"

4,600 lbs.

7

718-1505

12

Call 844-892-1734 for rates and reservations


INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

• 5,600 CFM @ 5.5” total static pressure

• 40° Delta F cooling performance (95°F entering and 55°F leaving air) • High-Static Pressure – push air further without experiencing significant CFM loss • Industrial construction • DDC controls and service friendly • Entering / leaving air temperature controls • Rental ready construction, controls, safeties and duct connections • Hot dipped galvanized skid & cage • Stainless steel cabinet construction • Overhead lifting with forklift pockets • Ducted return and supply air • 100% outside air rated at 95F DB • Low ambient control • High-static plenum fan • Two stage cooling with independent refrigerant circuits • Hot gas bypass on each circuit • Environmentally safe 410A refrigerant • Electronic temperature control • Panel mounted circuit breaker • Isolated high and low voltage control panel • Energy Guard applied to both evaporator and condenser coils for optimum corrosive protection • NEMA 7 Rated: Designed to contain an internal

explosion without causing an external hazard

CAPS 40 TON NEMA7 // PPKH-20TD-0NN0NN-5B2-P2-S1CEUP

Applications /

Heating, cooling and dehumidification of return or outside air for the following markets;

MAKE

MODEL

CFM

CAPACITY

MOISTURE REMOVAL

• Petrochemical • Food processing • Commercial buildings

VOLTAGE

STATIC PRESSURE

• Hospitals • Manufacturing • Data centers

DIMENSIONS (LWH)

• Film production • Pharmaceutical

WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PPKH-40TD-GP

5,600

40 Tons

236 lbs./hr

460V

5.5" @ 5,600 CFM

12' 9" x 6' 8" x 8'

6,300 lbs.

4

718-1800

CAPS

PPKH-40TD-XP

5,600

40 Tons

236 lbs./hr

460V

5.5" @ 5,600 CFM

12' 9" x 6' 8" x 8'

6,600 lbs.

7

718-1805

HercRentals.com

13

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

CAPS 40 TON NEMA4 // PPKH-40TD-0NN0NN-5E5-P2-S1CEUP


INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

INDUSTRIAL HIGH-STATIC AIR CONDITIONERS

CAPS 80 TON NEMA4 // PPKH-80TD-0NN0NN-5E5-P2-S1CEUP

• 10,000 CFM @ 5.5” total static pressure

• 42° Delta cooling performance, (95°F entering and 53° leaving air) • High-Static Pressure – push air further without experiencing significant CFM loss • Industrial construction • DDC controls and service friendly • Entering / leaving air temperature controls • Rental ready construction, controls, safeties and duct connections • Hot dipped galvanized skid & cage • Stainless steel cabinet construction • Overhead lifting with forklift pockets • Ducted return and supply air • 100% outside air rated at 95°F DB • Low ambient control • High-static plenum fan • Four (4) stage cooling with two (2) independent refrigerant circuits • Hot gas bypass on each circuit • Environmentally safe 410A refrigerant • Electronic temperature control • Panel mounted circuit breaker • Isolated high and low voltage control panel • NEMA 7 Rated: Designed to contain an internal

explosion without causing an external hazard

CAPS 80 TON NEMA7 // PPKH-80TD-0NN0NN-5B2-P2-S1CEUP

Applications /

Heating, cooling and dehumidification of return or outside air for the following markets;

• Petrochemical • Food processing • Commercial buildings

• Hospitals • Manufacturing • Data centers

• Film production • Pharmaceutical

MAKE

MODEL

CFM

CAPACITY

MOISTURE REMOVAL

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

NEMA RATING CAT-CLASS

CAPS

PPKH-80TD-GP

10,000

80 Tons

493 lbs./hr

460V

6" @ 10,000

18' x 6' 10" x 8' 4"

9,800 lbs.

4

718-2300

CAPS

PPKH-80TD-XP

10,000

80 Tons

493 lbs./hr

460V

6" @ 10,000

18' x 6' 10" x 8' 4"

9,800 lbs.

7

718-2305

14

Call 844-892-1734 for rates and reservations


AIR COOLED CHILLERS WITH INTEGRATED PUMP PACKAGES

AIR COOLED CHILLERS

CAPS 100 TON CHILLER // PCHH-100TC-0NN0NN-5E5-0-PG2CEUP

CAPS 200 TON CHILLER // PCHH-200TC-0NN0NN-5E5-0-PG2CEUP

• High efficiency scroll chiller with microprocessor controls • Integrated pump and hydronic specialties rated at 300 GPM@ 100 foot of head • Staged capacity with precise temperature control • ETL / UL listed • 0°F low ambient operations • 125°F high ambient operations • Shell and tube evaporator

• High efficiency screw chiller with microprocessor controls • Integrated pump and hydronic specialties rated at 600 GPM@ 100 foot of head • Staged capacity with precise temperature control • ETL / UL listed • 0°F low ambient operations • 125°F high ambient operations • Shell and tube evaporator

Applications /

Heating, cooling and dehumidification of return or outside air for the following markets;

• Petrochemical • Food processing • Commercial buildings

• Hospitals • Manufacturing • Data centers

AIR COOLED CHILLERS WITH INTEGRATED PUMP PACKAGES

Air Cooled Chillers provide comfort and process cooling solutions for both commercial and industrial applications. These self-contained chiller / pump packages are designed and constructed for user friendly operation and provide state of the art control of your fluid cooling needs for everyday use.

• Film production • Pharmaceutical

MAKE

MODEL

TYPE

CAPACITY

PUMP SIZE

CAP INLET

VOLTAGE

DIMENSIONS (LWH)

WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PCHH-100TC

100 Ton

100 Tons

300 gpm

4" Dixon Quick Connect

460V

17' 1" x 8' 4" x 8' 6"

11,000 lbs.

4

718-2560

CAPS

PCHH-200TC

200 Ton

200 Tons

600 gpm

4" Dixon or 6" Flanged

460V

24' 4" x 8' 4" x 8' 6"

20,000 lbs.

4

718-3060

HercRentals.com

15


CHILLED WATER AIR HANDLERS

CHILLED WATER AIR HANDLERS

CHILLED WATER AIR HANDLERS // HORIZONTAL

Chilled Water Air Handlers are designed to provide cooling and dehumidification using a chilled water source. These units provide both high-static air flow and large cooling capacity with an integrated variable speed drive. The industrial construction offers unit protection as well as easy mobility with forklift slots and / or certified overhead lifting points.

CAPS 50 TON // PAHH-50TC-0NN0NN-5E5-P2-VG2CEUP

CAPS 120 TON // PAHH-120TC-0NN0NN-5E5-P2-VG2CEUP

• 100% outside air or return air application • 6,250 CFM @ 5.0” total static pressure • VFD controlled indoor air blower • ETL listed • Supply & return air duct connections • 40° Delta (Delta variable by airflow and outside / return air application) • Two (2) 20” Supply Air Connections • Four (4) 20” Return / Outside Air Connections

• 100% outside air or return air application • 15,000 CFM @ 5.0” total static pressure • VFD controlled indoor air blower • ETL listed • Supply & return air duct connections • 40° Delta (Delta variable by airflow and outside / return air application) • Four (4) 20” Supply Air Connections • Six (6) 20” Return / Outside Air Connections

Applications /

• Petrochemical • Food processing • Commercial buildings

Heating, cooling and dehumidification of return or outside air for the following markets;

• Hospitals • Manufacturing • Data centers

• Film production • Pharmaceutical

MAKE

MODEL

TYPE

CFM

CAPACITY

DUCT SIZE

SUPPLY DUCTS

RETURN DUCTS

VOLTAGE

STATIC PRESSURE

DIMENSIONS (LWH)

WEIGHT

NEMA RATING

CAT-CLASS

CAPS

PAHH-50TC

50 Ton AHU

6,250

50 tons

20"

2

4

460V

5"

100" x 83" x 59"

3250 lbs.

4

718-1950

CAPS

PAHH-120TC

120 Ton AHU 15,000

120 tons

20"

4

6

460V

5"

144" x 101" x 64"

4350 lbs.

4

718-2650

16

Call 844-892-1734 for rates and reservations


CHILLED WATER AIR HANDLERS

CHILLED WATER AIR HANDLERS // VERTICAL

CHILLED WATER AIR HANDLERS

Chilled Water Air Handlers are designed to provide large volume cooling with an economical footprint and quiet sound level. Used in conjunction with a chilled water source, the units provide variable cooling capacity with an integrated variable speed drive. Designed for ultra-quick connection of ducting.

100 TON VERTICAL // AHU-100T • 100 ton capacity • Perfect for tight space constraints • Ductable up to 4 supply and 6 return • Cam-lock connections feed in and out for daisy chain options • CFM up to 24,000 with VFD

Applications /

• Entertainment (TV/Movie) • Tent cooling

MODEL

TYPE

CAPACITY

DUCT SIZE

SUPPLY DUCTS

RETURN DUCTS

VOLTAGE

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

AHU-100T

100 Ton AHU

100 Tons

20"

4

6 optional

480V

96" x 48" x 101"

4700 lbs.

718-2550

HercRentals.com

17


DEHUMIDIFIERS

DEHUMIDIFIERS

DESICCANT DEHUMIDIFIERS

Desiccant dehumidifiers are the solution you’ll need when working on or around water-damaged buildings or large closed spaces where managing humidity is mission critical. They lower moisture in the air, and materials and surfaces of the building itself. Electric, gas and propane models are available.

ARID-DRY // MS-7500 Industrial Mobile CDH-R-142RC1 • 5500 to 7500 CFM in one machine with variable frequency drive motors. • Reduced foot print 100"L X 50"W & weight 4,400#. Allows placement in confined spaces. • 8" rated extended static pressure (process air). With backward incline non-overloading fans. • Tri-Fuel Reactivation Electric and/or Natural or LP Gas Reactivation. STORAGE // 12 desiccant dehumidifiers can be loaded on a standard 53' flatbed trailer. 12 TOTAL

18

Call 844-892-1734 for rates and reservations


DEHUMIDIFIERS

DEHUMIDIFIERS

ARID-DRY // MS-2400/1000 Hi/Lo Mobile-Dry Units • Variable-Frequency Drive for CFM control from 1,000 to 2,500 CFM • Electric reactivation

Phoenix // 1200

Phoenix // D385

• 900 CFM (verify) • Fits Through a standard door • 8 inch reactivation outlet • Dual 8 inch process outlets • 344 Pints (43 gal) per day @ AHAM Moisture removal • Operating range of -10°F to 140°F

• 385 CFM • Easy to transport and set-up • Runs off of two (2) 115 volt plugs • Operating range of -10°F to 140°F • Reactivation airflow 75 CFM • Ultra low grains

Applications /

• Water damage restoration • Construction drying • Industrial condensation prevention

MAKE

MODEL

TYPE REACTIVATION

Phoenix

D385

Electric

Phoenix

1200

Electric

Arid Dry

MS-2400/1000

Electric

Arid Dry

MS-7500

Tri-fuel

HercRentals.com

AIR VOLUME

MOISTURE REMOVAL

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

385 CFM

116 Pints/Day @ AHAM

24" x 40" x 21"

105 lbs.

719-2060

900 CFM

43 Gallons/Day @ AHAM

26" x 35" x 45"

265 lbs.

719-2080

2400 cfm max

159 gallons @ 80F and 60%

92" x 35" x 63"

1,250 lbs.

719-1010

7500 cfm Max

577 gallons @ 80F and 60%

100" x 50" x 96"

4,400 lbs.

719-1030

19


DEHUMIDIFIERS

DEHUMIDIFIERS

LGR DEHUMIDIFIERS

LGR Dehumidifiers remove large amounts of water and moisture to help repair water damage during flood and restoration work. They can also help prevent mold and, for commercial businesses, protect from water and moisture damage.

Dri-Eaz // 7000XLi

Dri-Eaz // Revolution

• Advanced Crossflow Technology • Self-monitoring system. • Built-in humidistat and plain-English control panel messages • Sealed large-capacity pump basin • Ergonomic design. • Standard 12 in. ductable outlet

• Best low-grain performance in its class • Delivers “Large” dehumidifier performance yet fits where others don’t • Control panel displays inlet and outlet temp and RH in real time • Secure, compact stacking – transport multiple units on a handtruck • Fastest access for cleaning and maintenance

Applications /

• Restoration • Construction drying

MAKE

MODEL

MOISTURE REMOVAL (MAX)

MOISTURE REMOVAL (AT AHAM)

CFM RATING

AMP RATING

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

Dri Eaz

Revolution

10.1 Gal/Day

8 Gal/Day

121-180

6.2

22" x 13" x 18"

65 lbs.

719-2020

Dri-Eaz

7000XLi

29.3 Gal/Day

16.2 Gal/Day

325

8.3

20" x 33.5" x 20"

107lbs.

719-2040

20

Call 844-892-1734 for rates and reservations


AIR QUALITY CONTROL

AIR MOVERS

AIR QUALITY CONTROL

Air Movers are an important part of drying, especially in water damage restoration. By evaporating moisture from materials up into the air, when combined with dehumidifiers and other equipment, air movers contribute to the complete drying system.

Dri-Eaz // Ace TurboDryer • Very low amp draw • Six position versatility for handling a wide range of applications • Dry structures fast with 1800 actual CFM • Turn or tilt on non-skid rubber feet to switch operating positions • Compact design that's stackable for operation and storage

Dri-Eaz // Velo Airmover • Engineered airflow. Patent pending outlet design ensures even, broad-path airflow for fast, consistent drying across surfaces • Multiple operating positions - dry floors, ceilings, walls and stairways quickly and efficiently • Low profile with great portability • Stackable for compact storage • Low amp draw. Only 1.9 amps • Daisy-chain with GFCI outlet

MAKE

MODEL

CFM

AMPS

Dri-Eaz Dri-Eaz

Ace TurboDryer

2000

Velo Airmover

885

HercRentals.com

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

1.5

19" x 24" x 20.3"

33 lbs.

700-1140

1.9

24" x 9" × 18"

21 lbs.

700-1140

21


AIR QUALITY CONTROL

AIR QUALITY CONTROL

AIR SCRUBBERS

Air Scrubbers remove particles, gases and chemicals from the air. These portable filtration systems remove contaminants through a series of filters. These are vital on restoration jobs where mold, dust, asbestos, lead and chemical fumes become airborne during the restoration process.

Phoenix // Guardian • True 1,400 CFM capacity. • Performs one clean air change of a 12 x 14 foot room in less than one minute. • High airflow and multiple ducting options allow for the combination of negative or positive air flow control of an area and containment air scrubbing at the same time. • Accepts either 18" flexduct or 12" flex-duct with the included adapter.

Dri-Eaz // DefendAir HEPA 500 • Powerful fans motors maintain desired air flow and negative pressure • Easy transport and storage through compact design. • Specialty filters available for variable applications

Applications /

Mold Abatement, Restoration, Construction, Renovation, and Industrial Applications

MAKE

MODEL

MAX CFM

FILTRATION

TYPICAL FILTRATION ARRANGEMENT

COVERAGE @ 5 ACH

POWER REQUIREMENTS

DUCT DIAMETER

DIMENSIONS (LWH) WEIGHT

CAT-CLASS

Phoenix

Guardian

1,400

3-stage

Polyester/Pleated/ V-Bank HEPA

16,800 CF

110-120V / 12A

12/18"

39" x 25" x 25"

700-1520

121 lbs.

MAKE

MODEL

CFM

AMPS

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

Dri-Eaz

DefendAir HEPA 500

250-500

3

18.2" x 24.6" × 26.2"

44 lbs.

700-1560

22

Call 844-892-1734 for rates and reservations


AIR QUALITY CONTROL

// INSTANT RESPONSE

TRUCK // TRAILER // GEAR Let Herc Rentals deliver your complete package:

HercRentals.com

AIR QUALITY CONTROL

for all of your remediation, restoration, and portable cooling needs.

• Instant Response trailer • E-Z load ramp • Aux 110 shore power • Integrated racking • Truck rentals also available

23


PORTABLE GENERATORS

PORTABLE GENERATORS PORTABLE GENERATORS

Provide reliable power solutions for temporary or emergency power requirements. We carry a diverse mix of generators ranging from 14KW to 320KW.

Applications /

• Applications: • Emergency/disaster relief • Construction • Remediation/restoration

• Industrial/commercial facilities • Rock quarries • Petrochemical/refinery services • Catering/concessions

• Festivals/concerts • Film production • Air conditioning/chillers

MODEL

ENGINE

ENGINE MODEL

ENGINE TIER

KW PRIME

FUEL CONSUMPTION (GAL/HR. @ FULL LOAD)

DRY WEIGHT (LBS.)

WET WEIGHT (LBS.)

WEIGHT W/TRAILER (LBS.)

TRAILER DEMENSIONS

DCA15SPXU4F

Kubota

D1503

4F

14 (14.7)

1.09

1,179

1,367

2,080

100" x 57" x 22"

DCA20SPXU4F

Isuzu

4LE2T

4F

20 (22)

1.62

1,797

2,138

2,544

105" x 57" x 17"

DCA25SSIU4F

Isuzu

4LE2T

4F

20 (22)

1.62

1,797

2,138

2,544

105" x 57" x 17"

DCA36SPXU4F

Isuzu

4LE2X

4F

36 (40)

2.93

2,488

3,087

4,143

148" x 66" x 23"

DCA40SSKU4F

Kubota

V2403

4F

28.8 (29.7)

2.20

2,250

2,823

3,879

148" x 66" x 23"

DCA45SSIU4F

Isuzu

4LE2X

4F

36 (40)

2.93

2,337

2,976

4,023

148" x 66" x 23"

DCA70SSIU4F

Isuzu

4JJ1X

4F

56 (62)

4.40

3,329

4,211

5,171

166" x 72" x 21"

DCA70SSJU4i

John Deere

40458HFG92 4i

56 (62)

4.30

3,594

4,410

5,370

166" x 72" x 21"

DCA125SSIU4F

Isuzu

4HK1X

4F

100 (110)

7.11

5,291

6,702

8,421

182" x 80" x 25"

4045HFG93

4i

100 (110)

7.30

5,137

6,460

8,179

182" x 80" x 25"

6068HFG08

4F

120 (132)

8.40

6,615

7,497

11,536

209" x 87" x 26"

6068HFG09

4F

176 (194)

12.50

7,695

8,489

14,009

210" x 88" x 28"

6090HFG09

4F

240 (264)

17.20

9,658

10,912

16,805

234" x 96" x 25"

6WG1X

4F

320 (336)

22.50

12,280

13,184

19,949

265" x 94" x 28"

DCA125SSJU4i DCA150SSJU4F DCA220SSJU4F DCA300SSJU4F DCA400SSI4F

24

John Deere John Deere John Deere John Deere Isuzu

Call 844-892-1734 for rates and reservations


RELATED PRODUCTS

GROUND PROTECTION

DuraDeck // Light-duty

SignaRoad // Medium-duty

• Will not rot or splinter • Protects vehicles & equipment from excessive wear and damage • Surface traction prevents slippage and added safety • Saves time and labor costs, increasing efficiency

• High-quality 100% virgin HDPE composite matting • Quick and simple to install • Ranked #1 for strength, durability and traction • Saves time and labor costs, increasing efficiency • Eliminates environmental cross-contamination

STORAGE // About 500 light-duty sheets can be loaded in a standard US tractor trailer or 40ft ocean container

STORAGE // About 90 medium-duty sheets can be loaded in a standard US tractor trailer or 40ft ocean container

Applications /

• Roadways • Accessways • Special Events • Ground Protection

• Muddy and Soft Soil • Unstable and Uneven Ground • Extreme Weather and Climates • Oil and Gas

GROUND PROTECTION

Protect your job site and personnel when tasked with projects on uneven ground and muddy work sites. Wet or unsteady ground can cause trucks to become stuck, equipment to fail, and create a hazardous work environment for your team. Fortunately, Herc Rentals provides a portable, light-duty composite matting solution designed specifically to provide access roads and working platforms for vehicles, equipment, and personnel.

• Transmission and Distribution • Heavy-haul • Construction

MAKE

PART NUMBER

TYPE

WEIGHT

DIMENSIONS (LWH)

WEIGHT LOAD

CAT-CLASS

DuraDeck

100669

Light-duty

86 lbs.

8’x8’x.5”

250lbs psi

003-3589

SignaRoad

102909

Medium-duty

496 lbs.

6.83’x10’x.2.5”

400lbs psi

003-3590

HercRentals.com

25


ELECTRIC HEAT

ELECTRIC HEAT

PORTABLE ELECTRIC HEATERS

Portable electric heaters provide safe, fast, dry, odorless heat for enclosed spaces. Available in ranges from 1.6 kW to 60 kW. Ideal for job sites or offices, where 100% dry heat and flameless operations are required.

Phoenix // FireBird Compact 20 • 120 vac outlet - 12A-48A • Automatic internal 140ºF safety thermal cutout • Phoenix thermostat with 25’ connecting wire • Stackable for easy storage and transportation • Multiple heating, ducting, and electrical options for on-demand heating from inside or outside the drying space

Chromalox // Super Dragon Electric Heater • Available in 30 kW or 60 kW • Fan-only switch for recirculating room air, supplying fresh air source or capturing exhaust fumes • Two thermostats to set maximum inlet and outlet temperatures • Easy mobility

MAKE

MODEL

CFM

CAPACITY

BTU

HEATING AREA*

VOLTAGE

PHASE

AMP RATING

WEIGHT

CAT-CLASS

Phoenix

Compact 20

250

5 kW - 20 kW

20,000

300 sq ft

120V

1P

12A-48A

35 lbs

715-0020

Chromalox

SDRA-30-43

2,700

30 kW

102,360

2,200 sq ft

480V

3P

37.2A

150 lbs

715-0060

Chromalox

SDRA-60-43

2,700

60 kW

204,720

4,800 sq ft

480V

3P

73.3A

170 lbs

715-0070

26

Call 844-892-1734 for rates and reservations


ELECTRIC HEAT

ELECTRIC HEAT

DeWalt // 1.6 kW

DeWalt // 7 kW - 10 kW

DeWalt // 13 kW - 20 kW

• No monitoring required, can be operated unattended • No fumes or open flames • Includes an adjustable thermostat

• Thermostatically controlled two-stage operation • Dual output can run at 10kW or 7 kW • Electric-forced air single-phase heater for industrial and commercial usage

• Two-stage operation connects to 60A or 100A breakers • 100A service for high/low heat outputs • Fan-only setting for circulating air • Designed and certified as an unattended source of jobsite heat

Fostoria // Salamander 15-60 kW

Flagro // FLE-60 kW

DRY HEAT //

Does Not Add Moisture to the environment

Applications /

• Ductible • Inlet and outlet guards • Extremely quiet • High outlet air velocity • Highly mobile and easy to store

• Safety screens on both air intake and output openings • Thermostat adjustment 40o to 100o F • High limit thermal cutout switch / automatic reset

• Temporary heating for contractors and special events • Emergency situations - heat loss, thawing of frozen pipes

MAKE

MODEL

CFM

CAPACITY

BTU

HEATING AREA*

VOLTAGE

PHASE

AMP RATING

WEIGHT

CAT-CLASS

DeWalt

DXH165

135

1.6 kW

5,630

50 sq ft

115V

1P

13.5A

14 lbs

715-0010

DeWalt

DXH1000TS

350

7 kW

23,884

300 sq ft

240V

1P

30A

35 lbs

715-0030

DeWalt

DXH2000TS

661

13 kW

44,357

800 sq ft

240V

1P

60A

45 lbs

715-0050

Fostoria

FES-1524-1A

800

15 kW

51,195

900 sq ft

240V

1P

63A

69 lbs

715-0040

Flagro

FLE-60

3,300

60 kW

205,000

4,800 sq ft

480V

NA

NA

290 lbs

715-0070

HercRentals.com

27


INDIRECT FIRED

PORTABLE INDIRECT FIRED HEATERS INDIRECT FIRED

Portable indirect fired heaters operate like a mobile furnace with a fan forcing air over a heat exchanger where internal combustion occurs and fumes are exhausted through a stack.

Flagro // FVNP-400

Flagro // FVNP-750

• Steel lifting point • Heavy-duty pneumatic tires • Slim design for easy site mobility and transportation • Dual fuel options available

• Standard 208V - 1 PH or 230V - 3PH • Dual fuel, simply change from LP to NG in seconds • VFD (variable-frequency drive) for soft start • Skid base with four (4) sided fork pockets

Applications /

• Safe for use around people and animals • Emergency situations: heating system is under repair or drying applications

• Special events: ducting allows units to be placed outside and away from tents or temporary structures with warm air ducted into interior areas

MAKE

MODEL

TYPE

BTU

HEATING AREA*

CFM/SP

FUEL TANK

CONSUMPTION

RUN TIME**

VOLTAGE/AMPS

WEIGHT

CAT-CLASS

Flagro

FVNP-400

LP/NG

390,000

10,000 sq ft

2,500/2”

external

4.26 gal/hr (LP)

5.4 hrs

115V / 15 amps

365 lbs

715-0630

Flagro

FVNP-750

LP

750,000

20,000 sq ft

7,000/1.5”

external

37 lbs/hr (LP)

.62 hrs

230V / 3PH amps

1,390 lbs

715-0640

NG

750,000

20,000 sq ft

7,000/2.20”

external

800 cfh (NG)

n/a

230V / 3PH amps

1,390 lbs

715-0640

28

Call 844-892-1734 for rates and reservations


INDIRECT FIRED

INDIRECT FIRED

Flagro // FVO-400

Flagro // FVO-200

• Steel lifting point • Heavy-duty pneumatic tires • Slim design for easy site mobility and transportation • Built-in 42 gallon fuel tank

• Thermostatically controlled • Heavy-duty pneumatic tires and swivel lockable casters • Stackable for storage with built-in fuel tank

Wacker Neuson // HI 200

Wacker Neuson // HI 400

• Extended run time fuel tanks • Control panel offers convenient side outlet for attaching remote thermostat • Low temperature rating to -4o F (-20o C) on standard models

• Can handle various heating and drying applications at over 85% efficiency due to dedicated 2nd blower for combustion; one of the highest in the industry

MAKE

MODEL

TYPE

BTU

HEATING AREA*

CFM/SP

FUEL TANK

CONSUMPTION

RUN TIME**

VOLTAGE

WEIGHT

CAT-CLASS

Flagro

FVO-200

Diesel/K1

200,000

4,700 sq ft

1,500/NA

23

1.5 gal/hr

15 hrs

115V

330 lbs

715-0610

Flagro

FVO-400

Diesel/K1

390,000

10,000 sq ft

2,500/NA

42

2.75 gal/hr

14 hrs

115V

450 lbs

715-0620

Wacker

HI 200

Diesel

204,873

4,800 sq ft

1,530/.5”

27 gal

1.5 gal/hr

18 hrs

120V

240 lbs

715-0610

Wacker

HI 400HD

Diesel

408,596

10,500 sq ft

3,760/.5”

57 gal

2.9 gal/hr

19 hrs

120V

456 lbs

715-0620

HercRentals.com

29


INLINE HEATERS

INLINE HEATERS

INLINE HEATERS

Inline heaters provide additional heat when coupled with an existing air conditioner, desiccant dryer or inline blower for air movement.

United Cool Air // PIH30 / PIH60 / PIH150 • 30 kW and 60 kW models provide two stage heat, while the 150 kW model has four stage • Built-in thermostat controls the unit heat stages for the desired operation • Units designed for ducted applications using a blower from another unit

Recommended Accessory: • PILB5 Inline Blower • 5,000 CFM

Applications /

Heating, of recirculated air for the following markets;

• High Temp applications • Extreme cold temps

• Combine with a/c for a blended dehumidification system

MAKE

MODEL

CAPACITY

BTU

VOLTAGE

PHASE

AMP RATING

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

United Cool Air

PIH30

30 kW

102,360

220V / 460V

3P

42.4A / 88.6A

42 x 34 x 48

410 lbs

715-0210

United Cool Air

PIH60

60 kW

204,720

220V / 460V

3P

81.9A / 170.6A

53 x 34 x 48

520 lbs

715-0220

United Cool Air

PIH150

150 kW

511,800

460V

3P

203.9A

65 x 34 x 48

820 lbs

715-0230

30

Call 844-892-1734 for rates and reservations


SELF-CONTAINED SELF-CONTAINED INDIRECT HEATERS

Self-Contained units has a built in generator for easy start up. Tow up to the site your are heating and start it up!

SELF-CONTAINED

Built in generator

Wacker Neuson // HI 770XHD • Designed to run 24/7 in extreme environments to -60o F (-51o C) • Spill containment feature assures no diesel fuel, engine oil or coolant will contaminate the site • Machines are CSA certified • Heavy-duty fork pockets designed for easy load and unload for greater job-site mobility • Unique Recircul-Air design allows adjustable recirculation of warm inside air, resulting in huge fuel savings and even temperatures

*EXTENDED SERVICE TECHNOLOGY (EST) No heat loss downtime. No service interruptions for 3,000 hours or 125 days

MAKE

MODEL

TYPE

BTU

CFM/SP

FUEL TANK

CONSUMPTION

RUN TIME

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

Wacker

770XHD

Diesel

770,000

4,000/4”

235

5.5 gal/hr

43 hrs

187 x 94 x 88

5,700

715-0810

HercRentals.com

31


SELF-CONTAINED

SELF-CONTAINED

MAC // 800G Indirect Fired Heater • 800,000 BTU/hr (235 kW) of heat in a midsize heater • Temperature rise up to 180o F (82o C) • Air output volume of 3,900 cubic feet per minute • Capable of duct running long distances with minimal loss of air pressure or outlet temperature • Portable from site to site / forklift tubes / oil field skid • Proven indirect fired design • Made in the U.S.A.

*EXTENDED SERVICE TECHNOLOGY (EST) No heat loss downtime. No service interruptions for 3,000 hours or 125 days

MAC // 1.2G

MAC // 2.5ES

MAC // 4.2ES

• 1,200,000 BTU/hr (352 kW/hr) • Temperature rise up to 180o F (82o C) • 6,500 CFM @ 3" static pressure • Capable of duct running long distances with minimal loss of air pressure or outlet temperature • Portable from site to site • Proven indirect fired design

• 2,500,000 BTU/hr (352 kW/hr) • Temperature rise up to 180o F (82o C) • 12,000 CFM @ 3" static pressure • Capable of duct running long distances with minimal loss of air pressure or outlet temperature • Portable from site to site • Proven indirect fired design

• 4,200,000 BTU/hr (1,231 kW/hr) • Temperature rise up to 180o F (82o C) • 21,000 CFM @ 3" static pressure • Capable of duct running long distances with minimal loss of air pressure or outlet temperature • Portable from site to site • Proven indirect fired design

• Oil and Gas: heating frozen equipment • Mining: keeps personnel working comfortably • Energy: prevents outages by keeping equipment at appropriate operating temperatures

Applications /

• Construction: keeps crews productive, projects on schedule and profitable • Agriculture: reduces risk of spread of disease

MAKE

MODEL

TYPE

BTU

CFM/SP

FUEL TANK

CONSUMPTION

RUN TIME

L/W/H (IN)

WEIGHT

CAT-CLASS

MAC

800G

Diesel

800,000

3,900/3”

175

5.7 gal/hr

31 hrs

186 x 72 x 87

4,620 lbs

715-0810

MAC

1.2G

Diesel

1,200,000

6,500/3”

270

8.6 gal/hr

31 hrs

252 x 96 x 103

7,000 lbs

715-0820

MAC

2.5ES

Diesel

2,500,000

12,000/3”

130

17.9 gal/hr

7.3 hrs

249 x 101 x 95

9,000 lbs

715-0830

MAC

4.2ES

Diesel

4,200,000

21,000/3”

130

30 gal/hr

4.3 hrs

289 x 102 x 118

14,000 lbs

715-0840

32

Call 844-892-1734 for rates and reservations


DIRECT FIRED

DIRECT FIRED PORTABLE HEATERS

Direct fired portable heaters are portable and generally used in farms, warehouses, garages and construction sites with proper ventilation.

DIRECT FIRED

Mi-T-M // MH-0135

Mi-T-M // MH-0190

Mi-T-M // MH-0400

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

Applications /

• Farms • Workshops

Temporary heating of recirculated air for the following markets;

• Warehouses • Garages

• Construction Sites

MAKE

MODEL

TYPE

BTU

CFM

HEATING AREA*

FUEL TANK

CONSUMPTION

RUN TIME

WEIGHT

CAT-CLASS

Mi-T-M

MH-0075-0M10

Kerosene

75,000

240

2,000 sq ft

5 gal

.56 gal/hr

8.9 hrs

33 lbs

715-0410

Mi-T-M

MH-0135-0M10

Kerosene

135,000

540

4,000 sq ft

10 gal

1 gal/hr

10 hrs

57 lbs

715-0420

Mi-T-M

MH-0190-0M10

Kerosene

190,000

630

4,000 sq ft

13 gal

1.42 gal/hr

9.1 hrs

68 lbs

715-0450

Mi-T-M

MH-0400-0M10

Kerosene

400,000

1,400

9,000 sq ft

24 gal

3 gal/hr

8 hrs

159 lbs

715-0470

HercRentals.com

33


DIRECT FIRED

DIRECT FIRED

HeatStar // HS85FAV

HeatStar // HS170AVT

HeatStar // HS210-KT

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

Mi-T-M // 150

Mi-T-M // 375

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

• Powder coated steel handles for easy lifting • 10-inch pneumatic tires • Spare parts storage system • Fuel drain plug • Secured fully insulated ignition connection • Heavy-duty, high quality cast aluminum enclosed electric motor

MAKE

MODEL

CFM

TYPE

BTU

HEATING AREA*

FUEL TANK

CONSUMPTION

RUN TIME

WEIGHT

CAT-CLASS

HeatStar

HS85FAV

350

Propane

85,000

2,000 sq ft

20 lbs

2.3 gal/hr

8 hrs on low

21 lbs

715-0415

Mi-T-M

MH-0150-LMTO

400

Propane

150,000

3,800 sq ft

100 lbs

6.9 lbs/hr

18 hrs

23 lbs

715-0420

HeatStar

HS170AVT

450

Propane

170,000

4,000 sq ft

100 lbs

5.8 lbs/hr

17 hrs on low

32 lbs

715-0440

HeatStar

HS210-KT

400

Kerosene

210,000

6,000 sq ft

14 gal

1.60 gal/hr

8 hrs

87 lbs

715-0450

Mi-T-M

MH-0375-LM10

1,500

Propane

375,000

9,000 sq ft

(2) 100 lbs

17.4 lbs/hr

11.5 hrs

41 lbs

715-0460

34

Call 844-892-1734 for rates and reservations


INDUSTRIAL ELECTRIC

INDUSTRIAL ELECTRIC

CAPS // 150 kW Industrial Air Heater

Flagro // 150 kW Industrial Air Heater

• Four (4) stages of heating capacity control • VFD air volume control • Unit capable of 300o F leaving air temperature • 1” Thermax cabinet insulation • Integrated casters

• Three settings: 205,000 / 307,000 and 512,000 BTU • Thermostat included • Thermal cutoff safety device • Color-coded cam-lock power connectors • Permanent inlet filters • Fan speed inverter optimizes temperature rise • Simplified control panel

Applications /

• Special events • Large construction projects that require zero flame

Heating, cooling and dehumidification of recirculated air for the following markets;

• Restoration projects • Emergency heat • Zero fume

INDUSTRIAL ELECTRIC

Industrial electric heaters deliver clean dry heat to areas requiring maximum heat flow with low background noise. Ideal for either local or large-scale space heating.

• Indoor / outdoor uses with duct options

MAKE

MODEL

CAPACITY

BTU

CFM/SP

VOLTAGE

PHASE

AMP RATING

L/W/H (IN)

WEIGHT

CAT-CLASS

CAPS

PHUH-0NN-150KE0NN

150 kW

512,000

8,000/5”

480V

3P

206A

96 x 48 x 50 5/8

2,500 lbs

715-0240

Flagro

FLE-150

150 kW

512,000

6,300/.5”

480V

3P

161A

66 x 36 x 40

560 lbs

715-0240

HercRentals.com

35


FLAMELESS

FLAMELESS HEATERS FLAMELESS

Flameless heaters provide highly efficient heated air output with unprecedented safety in portable DOT-approved trailer mounted packages and are capable of ducting long distances with minimal loss of air pressure or outlet temperature.

WACKER NEUSON // HIF 1200

WACKER NEUSON // HIF 690

• 1.2 Million BTU/hr at max consumption (8.6 gph diesel) • Up to 4,000 CFM and 4” Water Column Static Pressure along with sealed alternator for longer service life • Environmentally friendly with spill containment • CCV heater and crankcase pressure switch ensure reliable performance • HIF 1200 is CSA certified, UL approved and TDG compliant

• 658,000 BTU/hr at max consumption (4.7 gph diesel) • Up to 4,000 CFM and 3.5” Water Column Static Pressure along with sealed alternator for longer service life • Environmentally friendly with spill containment • CCV heater and crankcase pressure switch ensure reliable performance • HIF 690 is CSA certified, UL approved and TDG compliant

MAKE

MODEL

BTU

CFM/SP

FUEL TANK

CONSUMPTION

RUN TIME

L/W/H (IN)

WEIGHT

CAT-CLASS

Wacker

HIF690

457,667

3,778/5”

100

3.3 gal/hr

30 hrs

155 x 67 x 80

3,230 lbs

715-1210

Wacker

HIF1200

1,204,000

6,500/4”

206

8.6 gal/hr

23 hrs

158 x 70 x 93

4,340 lbs

715-1240

36

Call 844-892-1734 for rates and reservations


FLAMELESS

FLAMELESS

MAC // 550F • 450,000* BTU • Output Air Volume: 1,400-3,500 CFM @ 5" static pressure • Normal Operating Fuel Rate: 3.00 GPH

MAC // 750F • 550,000* BTU • Output Air Volume: 2,650-5,500 CFM @ 5" static pressure • Normal Operating Fuel Rate: 3.55 GPH

MAC // 950F • 1,000,000* BTU • Output Air Volume: 3,000-6,000 CFM @ 5" static pressure • Normal Operating Fuel Rate: 7.1 gph (26.88 lph)

Applications /

Heating, cooling and dehumidification of recirculated air for the following markets;

• Oil and Gas • Mining

• Industrial Sector • Power Plants

MAKE

MODEL

BTU

CFM/SP

FUEL TANK

CONSUMPTION

RUN TIME

L/W/H (IN)

WEIGHT

CAT-CLASS

MAC

550F

550,000

3,500/5”

125

2.6 gal/hr

40 hrs

176 x 72 x 82

3,800 lbs

715-1210

MAC

750F

750,000

5,500/5”

165

3.55 gal/hr

46 hrs

192 x 72 x 85

5,720 lbs

715-1220

MAC

950F

950,000

6,000/5”

165

5.4 gal/hr

30 hrs

192 x 72 x 85

5,650 lbs

715-1230

HercRentals.com

37


HYDRONIC SURFACE

HYDRONIC SURFACE

Thawzall // TCH250 • Patented HeatZone® fluid distribution technology delivers heat more uniformly, thaws more quickly and saves a minimum of 24 gallons of fuel per day over its closest competitor • Superior thaw, cure, heat for any job • Delivers a blistering 250 MBH of heat with unparalleled uniformity through 3000’ (five zones of 600’) of 5/8” hydronic heat hose

Flex-Temp // Fusion 3000 • Site ready, this one-touch start machine is a portable hydronic surface heat system with multi-tasking proficiency • Ground thawing, cold weather concrete warming/curing, pre-pour warming, ground frost prevention and other heat applications for extreme cold • Maintains reliable performance throughout the winter • Optional remote and auto-control technologies provided

*EXTENDED SERVICE TECHNOLOGY (EST) No heat loss downtime. No service interruptions for 3,000 hours or 125 days

Wacker Neuson // E3000 • Reliable performance and trouble-free starts for up to 140 hours of run time • Provides maximum flow and ensures consistent heat delivery for thawing and curing applications

• Ground thawing • Cold weather concrete warming • Pre-pour warming

Applications /

• Ground frost prevention • Multi-zone layout: uses one zone for smaller jobs. Multiple zones

create higher return temps for a quicker more-effective thaw • Heat applications for extreme cold

MAKE

MODEL

TYPE

BTU

THAWING CAPACITY

CURING CAPACITY

EFFICIENCY

FUEL TANK

FUEL CONSUMPTION

RUN TIME

L/W/H (IN)

WEIGHT*

CAT-CLASS

Thawzall

TCH250

Diesel

234,000

6,000 sq ft

18,000 sq ft

82%

160 gal

1.75 gal/hr

72 hrs

170 x 84 x 96

5,600 lbs

715-1010

FlexTemp

Fusion3000

Diesel

234,000

6,000 sq ft

18,000 sq ft

87%

170 gal

1.75 gal/hr

97 hrs

178.5 x 96 x 91

8,295 lbs

715-1010

Wacker

E3000

Diesel

385,000

6,000 sq ft

18,000 sq ft

83%

230 gal

2.75 gal/hr

140 hrs

181 x 91 x 94

7,190 lbs

715-1020

38

Call 844-892-1734 for rates and reservations


APPLICATION GUIDE NEED HEAT?

PORTABLE ELECTRIC //

SELF-CONTAINED //

ADVANTAGES

ADVANTAGES

• Built in generator • 100% clean, dry heat - no moisture • No exhaust - can be used in confined spaces • No need for gas line or propane • Quiet operation

• Powerful - provides clean, safe, reliable air • Patented heat exchangers drive higher efficiency • Ducting long distances with minimal loss of pressure or temperature • Push-button controls make units easy to use • Flameless options are also available • Built -in generator

APPLICATIONS • Heating for contractors and special events • Emergency situations - heat loss, thawing of frozen pipes

CAPACITY 1.6 kW 10 kW

15 kW 20 kW

30 kW 60 kW

150 kW

APPLICATIONS • Oil and Gas: heating frozen equipment • Mining: personnel working comfortably • Energy: prevents outages • Construction: keeps crews productive, projects on schedule and profitable • Agriculture: reduces risk of spread of disease

CAPACITY

INDIRECT FIRED //

7,000 BTU 150,000 BTU 225,000 - 375,000 BTU

135,000 BTU 190,000 BTU 800,000 BTU

• 100% clean, dry heat with no open flame • Exhaust vented outside for confined spaces • Heavy-duty pneumatic tires and slim design for easy site mobility and transportation • Flexible fuel options: oil, diesel, propane (LP), natural gas (NG), or dual fuel (LP/NG)

APPLICATIONS • Safe for use around people and animals • Emergency situations: heating system is under repair or drying applications • Special events: ducting allows units to be placed outside and away from tents or temporary structures with warm air ducted into interior areas

CAPACITY 200,000 BTU 390,000 BTU

750,000 BTU

HYDRONIC SURFACE // ADVANTAGES • Long run times, maximized efficiency • Closed-loop system: moves heated fluid vertically or sideways • On-board fuel heater: adds 4% fuel savings with optimal fuel burn temp, assists boiler at high altitudes, prevents gelling in extreme cold weather • Spill containment and safety shut down sensors

APPLICATIONS • Ground thawing • Cold weather concrete warming/curing • Pre-pour warming • Ground frost prevention • Multi-zone layout: create higher return temps for a quicker more-effective thaw • Other heat applications for extreme cold

CAPACITY 203.000 BTU 280,000 BTU

ADVANTAGES

APPLICATION GUIDE

From small portable electric heaters to specialized configurations designed to heat large construction projects, we’ve got you covered. Please reference the application guide below to determine the heater that is best suited to your project needs.

385,000 BTU

DIRECT FIRED // ADVANTAGES • Kerosene and propane forced air heaters are portable and easy to operate • Extends heat into wide areas for a comfortable work environment in the harshest conditions

APPLICATIONS • Farms, workshops, warehouses, garages and construction sites with proper ventilation

CAPACITY 5,000 BTU 135,000 BTU 150,000 BTU

190,000 BTU 225,000 - 375,000 400,000 BTU

HVAC HYBRID // ADVANTAGES • 100% return air, 100% outside air or blended • Variable air volume up to 8,000 CFM / 20,000 CFM • Multi-stage heating up to 72 kW / 136 kW

APPLICATIONS • Temporary heating and cooling operation for contractors and special events • Temporary dehumidification for emergency recovery

CAPACITY 40 ton - 120 kW or 409,000 BTU 60 ton - 136 kW or 465,000 BTU

HercRentals.com

39


RELATED PRODUCTS

FUEL STORAGE CUBES/TANKS RELATED PRODUCTS

Serve the applications of multiple industries such as Construction, Oil & Gas, Power Generation, and more.

MAKE

TransCube Global // 10TCG

TransCube Global // 20TCG

• Compact, transportable, double-walled diesel fuel storage tank • 258 gallon tank quickly and easily supplies fuel

• Fully transportable, multi-tasking on-site fuel deployment • 552 gallon tank acts as a direct supply to stationary diesel engines or on-demand refueling equipment.

TransCube Global // 30TCG

TransCube Global // 50TCG

• Extend the run times of your diesel powered equipment and fuel more effectively • 793 gallon storage tank provides longer engine running time, reducing the number of site visits

• 1,198 gallons of fuel to your larger equipment • Fully transportable design and a lockable equipment cabinet provides security and hassle-free transportation of your fuel

MODEL

CAPACITY

DIMENSIONS (LWH)

WEIGHT

CAT-CLASS

TransCube

10TCG

300 gal

45.38" x 45.34" x 51.87"

1122 lbs

530-1030

TransCube

20TCG

500 gal

90.24" x 44.88" x 51.91"

1815 lbs

530-1050

TransCube

30TCG

800 gal

90.45" x 60.94" x 51.77"

2234 lbs

530-1070

TransCube

50TCG

1200 gal

90.87" x 90.85" x 51.93"

3696 lbs

530-1090

40

Call 844-892-1734 for rates and reservations


ACCESSORIES

OF ACCESSORIES AND OPTIONAL ADD-ONS TO COMPLETE YOUR JOB.

Flexible Ducting //

Chilled Water Hose //

Blower Units //

Power Distribution //

Ceiling/Tent Transitions //

Cable Kits //

Remote Thermostats //

Filters //

Connectors/Flanges/Diffusers //

HercRentals.com

41

ACCESSORIES

// WE CARRY A FULL LINE


GLOSSARY

GLOSSARY

ABBREVIATION SYMBOL TERM AC Ambient Air Ammeter Amp A Ampere Amps A Amperage BTU British Thermal Unit Centrifugal Compressor Compressor Condensor Condensate CFM Cubic Feet per Minute Dehumidification Delta T Desiccant DC Direct Current Dehumidification Desiccant Dehumidifier DX DX Unit Evaporator Generator GPP Hz Hertz IQ Instrument Quality Air k Kilo kWh Kilowatthour Latent Cooling NEMA Overload Parallel Circuit

DESCRIPTION

Phase Polarity Power PF Power Factor PSI Pounds per Square Inch Refrigerant Dehumidifier

A time relationship between two electrical quantities. For electrical charge, the indication of a charge as either positive (+) or negative (-). Voltage at a point would be indicated as being either positive or negative with respect to some other point. For magnetic poles, the indication as either north or south. The rate at which energy is consumed. In electronics it refers to the consumption of electrical energy in joules over time; measured in watts. The ratio of true power to the apparent power in a circuit, especially those that are not purely resistive. It is also equal to the cosine of the phase angle for the circuit. Unit for pressure of compressed air. Removing moisture from the air by using the refrigeration cycle.

42

The air surrounding you. An instrument used for measuring current. The unit of measurement for current. The amount of electric current in amperes. The amount of work needed to raise the temperature of 1 pound of water by 1 degree Fahrenheit. Compression of air/gas through turning impellers. Pump of a refrigeration system which draws a low pressure on the cooling side of a refrigerant cycle and squeezes or compresses the gas into the high pressure or condensing side of the cycle. A component in the basic refrigeration cycle that ejects or removes heat from the system. Liquid discharged from compressor and/or air treatment equipment. The process of removing moisture from the air and materials. Change in temperature. A substance such as silica gel or calcium oxide that is used as a drying agent. Current from a power source that continually flows in the same direction. An electrical source of constant polarity. A device or process used to removing moisture from the air or other materials. A hygroscopic substance used as a drying agent, it absorbs water and is used to remove moisture; a drying agent. Direct Expansion system. The part of a refrigeration system in which the refrigerant absorbs heat and changes from a liquid to a gas. A device that converts mechanical energy to electrical energy. Grains per pound - used in dehumidification terms. A unit of frequency equal to one cycle per second. Treated Compressed air from an oil-flooded compressor. After cooled, filtered air. Metric prefix for units of measurement equal to thousands (1000 or 103). As an example: 1 kilohertz (kHz) equals 1000hz. Unit of energy consumption equal to 1000 watt-hours or the energy consumed at the rate to one kilowatt (kW) for a time of one hour. Generally used to specify a large energy consumption over a specific time interval. The load is a measure of the amount of energy that is necessary to dehumidify the air in a building. National Electrical Manufacturers Association - sets standards to facilitate understanding between the manufacturers and the users of electrical products. A load in excess of the design limit for a circuit. A circuit with two or more loads (or sources) connected such that all have the same voltage but different currents. Each load can be operated independent of the others. Parallel sources should have equal voltage ratings.

Call 844-892-1734 for rates and reservations


GLOSSARY

// 2016 ProContractor Tools

Solutions Guide for the Professional Contractor

HercRentals.com

43

GLOSSARY

ABBREVIATION SYMBOL TERM DESCRIPTION Relative Humidity the amount of water vapor present in air expressed as a percentage of the amount needed for saturation at the same temperature. Resistance The opposition to current flow in a circuit; measured in ohms. Rotary Compressors Compression is produced by the positive action of rotating elements. SCFM Standard cubic feet per minute Standard Air Air at a temperature of 68°F, 14.70 PSI with a relative humidity of 36%. Per ASME. Static Pressure The amount of pressure a fan has to push and pull against to move air through a duct system. The resistance to airflow in a heating and cooling system’s components and duct work. Surge A very rapid increase of current or voltage. Thermistor A resistor made of semiconductor material having resistance that varies rapidly and predictably with temperature. Used as a temperature sensor, the resistance varies inversely with temperature. Therocouple A thermoelectric device used to measure temperatures accurately, consist of two dissimilar metals joined so that a potential difference is generated that is representative of the temperature of the junction. Transducer A device used to convert input energy of one form into output energy of another. Transformer A device used to transfer electric energy from one circuit to another. Generally used to convert one voltage-current relationship to another. Step-up transformer, increase the voltage while decreasing the current, and step-down transformer decrease the voltage while increasing the current. True Power The actual power consumed by a circuit; measured in watts. Two-stage Compressor Two Compression chambers with one air discharge. V Volt The unit by which an electromotive force or voltage is measured. V Voltage The force or electrical pressure that has the potential to cause electron flow in a circuit. Voltage Drop The difference in potential between two points caused by current flow through a component. Voltmeter An instrument used to measure voltage. W Watt The unit of measurement for power. One watt equals to the work done when one joule is used per second.


SIZING CALCULATIONS

// DETERMINING COOLING REQUIREMENTS: To determine cooling capacity for a particular application, the following can be used as a rough guide:

SIZING CALCULATIONS

Insulated areas: Provide 1 ton (12,000 BTU) of cooling capacity per 400 sq. ft. of surface area. Uninsulated areas: Provide 1 ton (12,000 BTU) of cooling capacity per 100 to 200 sq. ft. of surface area. Number of people present and the presence of equipment that generates heat will need to be taken into consideration when determining requirements.

// WATER DAMAGE RESTORATION: Two to three air changes per hour (ACH) are recommended for water damage restoration efforts.

1. Calculate the volume of the building in cubic feet (L x W x H).

2. Calculate the cubic square feet (CSF) for one air change (volume divided by 60).

3. Multiply the above number by two or three, depending on conditions.

// INDUSTRIAL CONDENSATION PREVENTION: In this application, desiccant dehumidifiers should be used in combination with air conditioning units. Dehumidifier flow should be approximately one-half of the air conditioner flow. 400 SCFM should be used per one ton of AC capacity.

// INDUSTRIAL PREPARATION AND SURFACE COATINGS: Temporary dehumidification of the inside of tanks that are being prepared for painting or industrial coating eliminates the potential for condensation. Sizing for Volume:

1. Calculate the volume of the tank in cubic feet (3.14 x Radius2 x H).

2. Calculate the SCFM for one air change (Volume divided by 60).

3. Calculate the dehumidification capacity required. (SCFM x ACH).

Sizing for Leakage:

1. Calculate the leakage in square feet from manholes and/or vents.

2. Calculate the dehumidification capacity required (leakage x 250 FPM).

The above calculations are to be used as a guide for estimation purposes only. For full sizing requirements and project consultation, call 888.777.2700 or visit your nearest ProSolutionsTM location.

44

Call 844-892-1734 for rates and reservations


CREDIT APPLICATION

CREDIT APPLICATION

HercRentals.com

45


CREDIT APPLICATION

CREDIT APPLICATION

46

Call 844-892-1734 for rates and reservations


ProClimate Solutions Guide  
Read more
Read more
Similar to
Popular now
Just for you