Issuu on Google+

hemrichelectric.com your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Table of Contents REFRIGERATION & AIR CONDITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Compressors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Refrigerant Handling Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

AIR CONDITIONING & HEATING CONTROLS . . . . . . . . . . . . . . . . . . . . . 53 Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Air Conditioning & Refrigeration Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Gas Heating Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Electric Heating Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Oil Heating Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 HVAC Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

VENTILATION & INDOOR AIR QUALITY . . . . . . . . . . . . . . . . . . . . . . . . . 169 Indoor Air Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 Zoning, Venting & Economizer Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Hydronic Heating Controls & Gas Water Heater Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

MOTORS & MOTOR ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 INSTALLATION & MAINTENANCE SUPPLIES . . . . . . . . . . . . . . . . . . . . 247 Welding Equipment & Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 Installation Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 Black Pipe & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 Linesets, Fittings & Copper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 PVC Pipe & Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 Screws & Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 HVAC Sundries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

CHEMICALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311 ELECTRICAL ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361 TEST INSTRUMENTS & TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399 Test Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421

INFORMATION & INDEXES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445 Product Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467 Source 1 Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471 Manufacturer Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 487 HVAC SERVICE PARTS

iii Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Refrigeration & Air Conditioning

Your Source1 Connection


info@hemrichelectric.com

Time Saver Compressors

COMPRESSORS

REFRIGERATION & AIR CONDITIONING

hemrichelectric.com

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

1


hemrichelectric.com

info@hemrichelectric.com

Time Saver™ Compressors

PREF

UPG P/N

MFG MODEL NO

MFG B/M NO

V-PH-HZ

CAP'Y

RLA

RUN CAP

SCT ID

DSC ID

FOOT MTG

HGHT

HTR

NEW

BRISTOL TIME SAVER STANDARD YES S1-01503547001 H29B18UABCA 230/208-1-60 35.6 7.4 30.0/370 0.750 0.375 7.50 X 7.50 13.53 Y YES S1-01503549001 H29B20UABCA 739009-1100-00 230/208-1-60 37.8 8.6 30.0/370 0.750 0.500 7.50 X 7.50 13.53 Y YES S1-01503431001 H29B24UABCA 739010-1101-00 208/230-1-60 24.2 9.6 35.0/370 0.750 0.375 7.50 X 7.50 14.03 Y YES S1-01503423001 H29B28UABCA 739000-1100-00 208/230-1-60 28.2 11.8 35.0/370 0.750 0.500 7.50 X 7.50 14.03 Y YES S1-01503424001 H29B30UABCA 739029-1101-00 208/230-1-60 29.8 12.4 40.0/370 0.750 0.500 7.50 X 7.50 14.53 Y YES S1-01503425001 H29B35UABCA 739003-1101-00 208/230-1-60 34.9 14.4 45.0/370 0.750 0.500 7.50 X 7.50 14.53 Y YES S1-01503561001 H23A383ABCA 208/230-1-60 37.9 17.0 35.0/440 0.750 0.500 7.50 X 7.50 14.90 Y YES S1-01502784004 H23A423ABCA 703056-06-0790 208/230-1-60 42.1 19.3 40.0/440 0.875 0.500 7.50 X 7.50 14.90 Y YES S1-01502349002 H23A463ABCA 701076-06-0399 208/230-1-60 45.6 21.6 40.0/440 0.875 0.500 7.50 X 7.50 14.90 Y YES S1-01502031001 H23A543ABCA 208/230-1-60 55.1 24.4 45.0/440 0.875 0.500 7.50 X 7.50 16.40 Y < YES S1-01502190002 H23A563ABCA 703304-18-0836 208/230-1-60 55.6 24.6 55.0/440 0.875 0.500 7.50 X 7.50 16.40 Y BRISTOL TIME SAVER PREMIUM YES S1-01503760001 H20J173ABCA 750069-1000-02 208/230-1-60 16.8 7.1 30.0/370 0.750 0.500 7.50 X 7.50 14.19 Y < YES S1-01503821001 H21J19BABCA 208/230-1-60 19.0 8.0 35.0/370 0.750 0.500 7.50 X 7.50 14.44 Y < YES S1-01503822001 H21J24BABCA 750123-1000-02 208/230-1-60 24.0 10.1 30.0/370 0.750 0.500 7.50 X 7.50 15.53 Y < YES S1-01503636001 H20J273ABCA 750061-1000-00 208/230-1-60 26.8 11.0 30.0/440 0.750 0.500 7.50 X 7.50 15.05 Y YES S1-01503823001 H21J30BABCA 750127-1000-01 208/230-1-60 29.7 11.8 40.0/370 0.750 0.500 7.50 X 7.50 15.80 Y < YES S1-01503824001 H21J34BABCA 208/230-1-60 34.1 13.2 45.0/370 0.750 0.500 7.50 X 7.50 15.80 Y < YES S1-01503699004 H23C383ABCA 715025-1000-02 208/230-1-60 38.4 19.5 55.0/370 0.750 0.500 7.50 X 7.50 15.53 N < YES S1-01503657004 H23C423ABCA 715022-1000-01 208/230-1-60 42.3 21.0 60.0/370 0.750 0.500 7.50 X 7.50 15.53 N YES S1-01503714004 H23C473ABCA 715024-1000-00 208/230-1-60 47.4 24.4 60.0/370 0.875 0.500 7.50 X 7.50 16.53 N < YES S1-01503679004 H23R543ABCA 719037-1000-00 208/230-1-60 53.7 25.0 60.0/370 0.875 0.500 7.50 X 7.50 17.16 N YES S1-01503654004 H23R583ABCA 719035-1000-02 208/230-1-60 57.7 28.8 80.0/370 0.875 0.500 7.50 X 7.50 17.16 N COPELAND TIME SAVER STANDARD YES S1-01503830001 CR16K6-PFV 970 208/230-1-60 16.3 9.6 25.0/370 0.750 0.375 7.50 X 7.50 13.19 Y < YES S1-01503826001 CR20K6-PFV 970 208/230-1-60 19.6 10.9 30.0/370 0.750 0.375 7.50 X 7.50 13.31 Y < YES S1-01503831001 CR22K6-PFV 970 208/230-1-60 22.1 10.9 30.0/370 0.750 0.375 7.50 X 7.50 13.31 Y < YES S1-01502760004 CR28K6-PFV 230 208/230-1-60 28.2 15.3 35.0/370 0.750 0.500 7.50 X 7.50 13.56 N YES S1-01503828001 CR30K6-PFV 970 208/230-1-60 30.0 16.0 35.0/370 0.750 0.500 7.50 X 7.50 13.81 Y < YES S1-01503832001 CR34K6-PFV 970 208/230-1-60 34.5 16.6 50.0/370 0.750 0.500 7.50 X 7.50 14.06 Y < YES S1-01502422701 CR38K6-PFV 270 208/230-1-60 38.2 19.0 40.0/440 0.750 0.500 7.50 X 7.50 14.31 Y YES S1-01502315701 CR42K6-PFV 271 208/230-1-60 42.0 20.4 40.0/440 0.750 0.500 7.50 X 7.50 14.56 Y YES S1-01503833001 CR47KQ-PFV 970 208/230-1-60 47.0 24.6 45.0/440 0.875 0.500 7.50 X 7.50 14.81 Y < YES S1-01503834001 CR53KQ-PFV 970 208/230-1-60 53.0 29.0 60.0/440 0.875 0.500 7.50 X 7.50 14.81 Y < YES S1-01501606705 CRN5-0500-PFV 970 208/230-1-60 59.0 34.3 55.0/440 0.875 0.500 7.50 X 7.50 16.50 Y COPELAND TIME SAVER PREMIUM YES S1-01503590004 ZR18K4-PFV 950 208/230-1-60 18.0 10.7 35.0/370 0.750 0.500 7.50 X 7.50 14.86 N YES S1-01503527004 ZR22K4-PFV 930 208/230-1-60 22.0 14.86 N 12.1 40.0/370 0.750 0.500 7.50 X 7.50 YES S1-01503487004 ZR24K4-PFV 930 208/230-1-60 24.0 13.6 35.0/370 0.750 0.500 7.50 X 7.50 14.86 N YES S1-01502721004 ZR28K3-PFV 230 208/230-1-60 26.0 15.0 45.0/370 0.750 0.500 7.50 X 7.50 14.81 N YES S1-01502761004 ZR30K3-PFV 230 208/230-1-60 30.5 15.0 45.0/370 0.750 0.500 7.50 X 7.50 15.71 N YES S1-01502764004 ZR36K3-PFV 230 208/230-1-60 36.5 18.4 50.0/370 0.750 0.500 7.50 X 7.50 15.71 N YES S1-01502690704 ZR40K3-PFV 230 208/230-1-60 40.0 20.0 55.0/370 0.750 0.500 7.50 X 7.50 16.25 N YES S1-01502773004 ZR42K3-PFV 230 208/230-1-60 42.8 20.4 60.0/370 0.750 0.500 7.50 X 7.50 16.25 N < YES S1-01503494004 ZR47K3-PFV 935 208/230-1-60 48.2 21.4 60.0/440 0.750 0.500 7.50 X 7.50 16.95 N YES S1-01502975004 ZR54K3-PFV 250 208/230-1-60 54.0 28.0 80.0/370 0.875 0.500 7.50 X 7.50 17.75 N YES S1-01502620704 ZR57K3-PFV 250 208/230-1-60 57.0 32.1 80.0/370 0.875 0.500 7.50 X 7.50 17.75 N NOTE: Source 1 differentiates between Standard and Premium Compressors in its Timesaver offering. For Copeland, standard compressors are reciprocating compressors and premium compressors are scrolls. For Bristol, the standard compressors are reciprocating compressors and the premium compressors are either Benchmark Scrolls or Benchmark Reciprocating Compressors.

2

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HVAC SERVICE PARTS

3 Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BRISTOL COMPRESSORS

G Series—H2BG, H25G & H2NG Single Speed 3 Phase 60 Hz Rotolock w/Sight Glass G Series Compressors are packed without motor protection module. H2BG & H25G models do not require motor protector module (internal line break). SOURCE 1 PART NO. S1-01503333000 S1-01503334000 S1-01503367000 S1-01503368000 S1-01503369000 S1-01503370000 S1-01503371000 S1-01503372000 S1-01503335000 S1-01503336000 S1-01503338000 S1-01503340000

BRISTOL MODEL NO.

BRISTOL B/M

BTUs

SUCT. TUBE

DISCH. TUBE

CRANK CASE HEATER

MLP

H25G144DBDE H25G144DBEE H2BG094DBDE H2BG094DBEE H2BG104DBDE H2BG104DBEE H2BG124DBDE H2BG124DBEE H2NG184DPEF H2NG204DREF H2NG244DREF H2NG294DPEF

702503 702504 702208 702201 702214 702209 702241 702215 700512 700745 700748 700515

140,000 140,000 88,700 88,700 103,900 100,300 121,500 119,000 183,200 212,400 252,900 287,300

ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK

ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK

YES YES YES YES YES YES YES YES YES YES YES YES

$3829.65 3829.65 3441.14 3441.14 3966.68 3792.05 4111.20 4183.96 6509.04 6922.48 6984.35 7189.03

G Series Two Speed 3 Phase 60 Hz Rotolock w/Sight Glass SOURCE 1 PART NO. S1-01503344000 S1-01503345000 S1-01503346000 S1-01503347000 S1-01503348000 S1-01503349000 S1-01503350000 S1-01503351000 S1-01503352000 S1-01503353000

BRISTOL MODEL NO.

BRISTOL B/M

BTUs

SUCT. TUBE

DISCH. TUBE

CRANK CASE HEATER

MLP

H2NG104GPDE H2NG104GPEE H2NG124GPDE H2NG124GPEE H2NG184GPDF H2NG184GPEF H2NG204GPDF H2NG204GPEF H2NG244GPDF H2NG244GPEF

700771 700774 700772 700775 700691 700695 700692 700696 700693 700697

101,800 101,800 119,400 119,400 183,200 183,200 212,400 212,400 252,900 252,900

ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK

ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK ROTOLOCK

YES YES YES YES YES YES YES YES YES YES

$4391.92 5126.83 4716.42 4716.42 6897.01 6678.49 8070.76 7388.73 7353.73 7353.73

NOTE: THE H2NG MODELS REQUIRE EXTERNAL MOTOR PROTECTION THAT IS NOT INCLUDED IN THE MLP. PROTECTION MODULE FOR H2NG094-124 IS PART NUMBER S1-02537024000. PROTECTION MODULE FOR H2NG144-294 IS PART NUMBER S1-02537025000.

BRISTOL RECIPROCATING COMPRESSORS

G Series Single Speed 3 Phase 60 Hz Sweat Connections G Series Compressors are packed without motor protection module. H25G models do not require motor protector module (internal line break). SOURCE 1 PART NO. S1-01502118002 S1-01502124002 S1-01503376000 S1-01503377000 S1-01503378000

BRISTOL MODEL NO.

BRISTOL B/M

BTUs

SUCT. TUBE

DISCH. TUBE

CRANK CASE HEATER

SIGHT GLASS

MLP

H25G144DBDE H25G144DBEE H2NG204DREF H2NG204FRDF H2NG244DREF

702520 702389 702190 702243 702234

140,000 140,000 212,400 212,400 252,900

1-1/8 1-1/8 1-1/8 1-1/8 1-1/8

7/8 7/8 1-1/8 1-1/8 1-1/8

YES YES YES YES YES

YES YES NO YES YES

$3829.65 3722.03 6811.54 6984.77 7088.13

G Series Two Speed 3 Phase 60 Hz Sweat Connections SOURCE 1 PART NO. S1-01503388000

BRISTOL MODEL NO.

BRISTOL B/M

H2NG184GPEF

700938

BTUs

SUCT. TUBE

DISCH. TUBE

CRANK CASE HEATER

SIGHT GLASS

MLP

183,200

1-1/8

1-1/8

YES

NO

$6765.41

NOTE: THE H2NG MODELS REQUIRE EXTERNAL MOTOR PROTECTION THAT IS NOT INCLUDED IN THE MLP. PROTECTION MODULE FOR H2NG094-124 IS PART NUMBER S1-02537024000. PROTECTION MODULE FOR H2NG144-294 IS PART NUMBER S1-02537025000.

4

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BRISTOL RECIPROCATING COMPRESSORS

H2BG/H2NG Series For Air Conditioning & Heat Pump Application Features: •Inherent motor protection •Low vibration & noise •Painted shell •+ Suitable for 50 Hz. operation •Refrigerant — HCFC-22 •Sight glass on all models •High efficiency - up to 10.4 EER

SOURCE 1 PART NO. S1-01502701701 S1-01502704701 S1-01502705701 S1-01502706701 S1-01502703701 S1-01502124002 S1-01502118002 S1-01502336000

+ + + + +

+

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

H2BG094DBDE H2BG094DBEE H2BG104DBEE H2BG124DBEE H2BG124DBDE H25G144DBEF H25G144DBDF H2NG184DPDF

88,700 88,700 103,900 119,000 121,500 140,000 144,100 183,200

230/208-3-60 460-3-60 460-3-60 460-3-60 230/208-3-60 460-3-60 208/230-3-60 230/208-3-60

RLA LRA EER DWG NO

SUCT DISCH OVALL ID ID HT (H)

24.0 12.3 14.6 17.0 36.0 21.6 43.1 51.8

1-1/8 7/8 1-1/8 7/8 1-1/8 7/8 1-1/8 7/8 1-1/8 7/8 1-1/8 7/8 1-1/8 7/8 1-3/4 * 1-1/8 *

145.0 72.0 87.0 85.0 205.0 126.0 252.0 234.0

10.3 10.3 10.4 9.9 10.1 10.1 10.1 10.3

H2BG-1 H2BG-1 H2BG-1 H2BG-1 H2BG-1 N/A N/A H2NG-2

17.6 17.6 18.3 18.3 18.3 20.6 20.9 22.4

FOOT PRINT

CCH

SHIP WT. (LBS.)

MLP

9.5 X 9.5 9.5 X 9.5 9.5 X 9.5 9.5 X 9.5 9.5 X 9.5 9.5 X 9.5 9.5 X 9.5 10.5 X 10.5

Y Y Y Y Y Y Y Y

138 138 153 155 155 176 176 252

$3373.88 3446.55 3778.49 4073.17 4131.11 3722.03 3829.65 6509.04

* ROTO-LOCK threaded connections * NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

5


hemrichelectric.com

info@hemrichelectric.com

BENCHMARK RECIPROCATING COMPRESSORS

H20J Series For Air Conditioning & Heat Pump Application SOURCE 1 PART NO. S1-01503760001 S1-01503769001 S1-01503768001 S1-01503636001 S1-01503774001 S1-01503777001 S1-01503783001 S1-01503782001 S1-01503937001 S1-01503784001 S1-01503787001 S1-01503785001 S1-01503684001 S1-01503651001 S1-01503681001 S1-01503652001 S1-01503791001 S1-01503682001 S1-01503685001 S1-01503653001 S1-01503795001 S1-01503683001 S1-01503686001 S1-01503800001 S1-01503801001 S1-01503802001 S1-01503799001

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA EER SUCT DISCH

OVALL HT (H)

CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

H20J173ABCA H20J253DBFA H20J253DBVA H20J273ABCA H20J293DBLA H20J313ABCA H20J323DBFA H20J323DBVA H20J323DBLA H20J353ABCA H20J353DBFA H20J353DBLA H20J383DBFA H20J383DBLA H20J383DBVA H20J403DBLA H20J403ABCA H20J403DBEA H20J403DBFA H20J423DBDA H20J423ABCA H20J423DBEA H20J423DBFA H20J443DBDA H20J443DBEA H20J443DBFA H20J443ABCA

16,900 24,200 24,200 26,800 29,090 30,250 32,000 32,000 32,300 34,450 34,500 34,500 37,900 37,900 37,900 40,500 40,700 40,700 40,700 41,600 41,800 41,800 41,800 44,100 44,100 44,100 44,220

230-1-60 575-3-60 380/460-3-60 208/230-1-60 230-3-60 230-1-60 575-3-60 380/460-3-60 208/230-6-60 230-1-60 575-3-60 200/230-3-60 575-3-60 208/230-3-60 460-3-60 208/230-3-60 230-1-60 460-3-60 575-3-60 208/230-3-60 230-1-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 230-1-60

7.1 N/A 3.6 11 8.2 11.9 3.7 4.7 8.5 13.1 3.9 9.2 4 10.2 5 11 17.1 5.4 4.3 11.2 17 5.5 4.4 11.7 5.8 4.6 17.8

44 26 32 68.0 68 78 36 45 72 78 36 72 34.0 84.0 42.0 84.0 102 42.0 36.0 84.0 102 42.0 34.0 88.0 42.0 36.0 102

13.89 14.188 14.188 15.03 14.75 15.25 15.53 15.53 15.25 15.25 15.53 15.53 15.78 13.969 15.78 13.969 15.5 15.78 15.78 15.78 15.5 15.78 15.78 15.78 15.78 15.78 15.5

23 - 30W YES YES YES 23 - 30W 23 - 30W YES YES YES 23 - 30W YES YES YES YES YES YES 23 - 30W YES YES YES 23 - 30W YES YES YES YES YES 23 - 30W

30/370 N/A N/A 30.0/440 N/A 40/370 N/A N/A N/A 45/370 N/A N/A N/A N/A N/A N/A 50/370 N/A N/A N/A 65/370 N/A N/A N/A N/A N/A 65/370

67 69.5 69.5 77 71.5 82 78 78 81.1 82 78 78 80 80 80 80 84 80 80 80 84 80 80 80 80 80 84

$ 901.82 1130.58 1130.60 974.34 1057.73 994.67 1274.03 1274.03 1299.01 1055.25 1204.63 1117.00 1391.89 1354.61 1354.61 1247.55 1222.78 1247.55 1372.30 1379.45 1104.63 1379.45 11379.45 1379.39 1260.70 1216.78 1109.26

10.7 N/A 11.1 11.1 13 11.3 11.5 11.5 11.3 11.5 11.5 11.5 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.3 11.2 11.2 11.2 11.2

3/4 S 0.75 0.75 0.75 3/4 S 3/4 S 0.75 0.75 0.75 3/4 S 0.75 0.75 0.75 0.75 0.75 0.75 3/4 S 0.75 0.75 0.75 3/4 S 0.75 0.75 0.75 0.75 0.75 3/4 S

1/2 E 0.5 0.5 0.5 1/2 E 1/2 E 0.5 0.5 0.5 1/2 E 0.5 0.5 0.5 0.5 0.5 0.5 1/2 E 0.5 0.5 0.5 1/2 E 0.5 0.5 0.5 0.5 0.5 1/2 E

* NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

H21J Series SOURCE 1 PART NO. S1-01503848001 S1-01503849001 S1-01503985001 S1-01503851001 S1-01503852001 S1-01503823001 S1-01503838001 S1-01503837001 S1-01503824001 S1-01503853001 S1-01503854001 S1-01503815001 S1-01503839001

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

SUCT

DISCH

OVALL HT (H)

CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

H21J14BABCA H21J15BABCA H21J17BABCA H21J303DBLA H21J303DBVA H21J30BABCA H21J323DBLA H21J32BABCA H21J34BABCA H21J363DBLA H21J363DBVA H21J36BABCA H21J38BABCA

13,200 14,300 18,300 29,400 29,700 29,700 30,900 30,900 34,200 35,200 35,200 35,900 39,000

208/230-1-60 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-1-60

5.4 6 7 8 4.5 11.8 8.3 12.3 13.2 9.2 5 14.1 15.4

36 36 41 72 45 78 72 78 78 71 45 78 86

10.5 10.5 11.1 11.5 11.5 11.4 11.6 11.4 11.5 11.4 11.5 11.4 11.6

3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S

1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E 1/2 E

13.89 13.89 13.75 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.75

YES YES YES YES YES YES YES YES YES YES YES YES YES

35.0/370 35.0/370 35.0/370 N/A N/A N/A N/A 40.0/370 45.0/370 N/A N/A 45.0/370 45.0/370

72 69.5 71.5 86.6 77 81 80 86.6 83.2 77 78 83 84

$ 776.40 1062.07 1016.39 1363.72 1363.72 1089.90 1412.14 1191.68 1132.76 1412.14 1412.14 1170.75 1168.78

* NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

6

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BRISTOL RECIPROCATING COMPRESSORS

H23A Series For Air Conditioning & Heat Pump Application Features: • Inherent motor protection • Low vibration & noise • Painted shell • Refrigerant — HCFC-22

• Foot print: 7.5 x 7.5 • Quick connect wiring connections • High efficiency - up to 10.5 EER

SOURCE 1 PART NO.

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

CONF.

SUCT ID

HT (S)

S1-01503561005 S1-01503137005 S1-01503286004 S1-01503286005 S1-01502784005 S1-01502933005 S1-01502039002 S1-01502037005 S1-01502349005 S1-01502091005 S1-01501647005 S1-01502090005 S1-01502050005 S1-01502049005 S1-01502031005 S1-01503148005 S1-01502032005 S1-01502190005 S1-01502935005 S1-01502193005 S1-01502191005 S1-01502187005 S1-01502120005 S1-01502046005 S1-01502114005

H23A383ABCA H23A383DBEA H23A383DBLA H23A383DBLA H23A423ABCA H23A423DBEA H23A423DBFA H23A423DBLA H23A463ABCA H23A463DBEA H23A463DBFA H23A463DBLA H23A503DBEA H23A503DBLA H23A543ABCA H23A543DBEA H23A543DBLA H23A563ABCA H23A563DBEA H23A563DBFA H23A563DBLA H23A623ABCA H23A623DBEA H23A623DBFA H23A623DBLA

37,900 37,900 37,900 37,900 42,100 42,100 42,100 42,100 46,300 46,300 46,300 46,300 49,300 49,300 53,400 53,400 55,100 55,600 55,600 55,600 55,600 60,800 60,800 60,800 60,800

208/230-1-60 460-3-60 230/200-3-60 208/230-3-60 208/230-1-60 460-3-60 575-3-60 208/230-3-60 208/230-1-60 460-3-60 575-3-60 208/230-3-60 460-3-60 208/230-3-60 208/230-1-60 460-3-60 208/230-3-60 208/230-1-60 460-3-60 575-3-60 208/230-3-60 208/230-1-60 460-3-60 575-3-60 208/230-3-60

17 5.2 10.4 10.4 18.7 5.7 4.7 11.4 21.4 6.3 5.5 12.6 6.8 13.7 24.4 7.3 15.4 24.7 7.7 6.1 15.3 28.2 8.5 6.8 17

97 39 78 78 110 39 36.0 78 118 45 36 90 53 106 138 53 106 142 62 50 124 178 62 50 124

10.3 10.4 10.4 10.4 10.3 10.4 10.4 10.4 10.2 10.4 10.5 10.4 10 10 10 10.2 10.1 10.2 10.4 10.4 10.4 10 10.2 10.2 10.2

VERT VERT HORIZ VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT VERT

3/4 3/4 7/8 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

14.25 14.188 12.5 14.25 14.025 14.188 14.5 14.25 14.062 14.062 14.062 14.062 15.562 15.562 15.562 15.562 15.562 15.562 15.562 15.562 15.562 15.562 15.562 15.562 15.562

+

DISCH OVALL ** ID HT (H) CCH 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

14.906 14.906 14.906 14.906 14.906 14.906 14.906 14.906 14.906 14.906 14.906 14.906 16.406 16.406 16.406 16.406 16.406 16.406 16.406 16.406 16.406 16.406 16.406 16.406 16.406

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

*RUN CAP 35.0/440 N/A N/A N/A 40.0/440 N/A N/A N/A 40.0/440 N/A N/A N/A N/A N/A 45.0/440 N/A N/A 55.0/440 N/A N/A N/A 55.0/440 N/A N/A N/A

SHIP WT. (LBS.)

MLP

83 79 78.5 80.5 75 79 78.5 87.5 79 78 79 84 85 65 84.3 85 93 86 87 87 98.5 86 86 91.67

$1069.08 1169.74 1278.03 1278.03 1041.60 1250.75 1225.47 1233.68 1164.90 1344.10 1384.24 1378.52 1482.39 1470.82 1249.57 1291.25 1432.81 1261.70 1397.08 1481.17 1455.98 1532.71 1348.46 1557.72 1348.46

** CCH - Y = Yes, N = No, W = Well provided + Suitable for 50 Hz. operation * NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

7


hemrichelectric.com

info@hemrichelectric.com

BRISTOL RECIPROCATING COMPRESSORS

H28A Series

SOURCE PART NO.

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

ID

S1-01503285001 S1-01503199001 S1-01503197001 S1-01503198001 S1-01503697001 S1-01503202001 S1-01503200001 S1-01503201001 S1-01503205001 S1-01503203001 S1-01503204001 S1-01503206001

H28A383ABCA H28A383DBFA H28A383DBLA H28A383DBVA H28A423ABCA H28A423DBFA H28A423DBLA H28A423DBVA H28A503DBFA H28A503DBLA H28A503DBVA H28A543DBVA

38,100 38,700 38,700 38,700 43,350 44,000 44,000 44,000 49,500 49,500 49,500 53,500

208/230-1-60 575-3-60 200/230-3-60 460-3-60 208/230-1-60 575-3-60 200/230-3-60 460-3-60 575-3-60 200/230-3-60 460-3-60 460-3-60

17.2 4.1 10.4 5.2 18.4 4.6 11.6 5.8 5.4 12.9 6.6 7.1

118.0 44 110 54 118 44 110 54 58 137 69 69

10.9 11.3 11.3 11.3 10.8 11.2 11.2 11.2 11.2 11.2 11.2 11.0

7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

SUCT HT (S) 14.0 14.0 14.0 14.0 14.0 15.6 15.6 15.6 15.6 15.6 15.6 15.6

ID

DISCH HT (D)

1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3

OVALL HT (H)+

CCH

WIRE CONN

*RUN CAP

SHIP WT. (LBS.)

MLP

16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1

Y Y Y Y Y Y Y Y Y Y Y Y

Q S S S Q S S S S S S S

50.0/370 N/A N/A N/A 60.0/370 N/A N/A N/A N/A N/A N/A N/A

90.5 90.5 90.5 90.5 88.5 90.5 90.5 90.5 100 90.5 100 100

$1055.43 1285.63 1287.31 1287.31 1114.94 1337.17 1345.88 1345.88 1474.83 1474.83 1481.00 1459.95

+Overall height for compressor only. Height does not include isolator. *NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

8

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BRISTOL RECIPROCATING COMPRESSORS

H29A/H29B Series

SOURCE 1 PART NO. S1-01503427001 S1-01503543001 S1-01503547001 S1-01503547991 S1-01503901005 S1-01503892005 S1-01503549001 S1-01503551001 S1-01503431001 S1-01503816005 S1-01503893005 S1-01502313001 S1-01503898005 S1-01503423001 S1-01503424991 S1-01503608001 S1-01503424001 S1-01503607001 S1-01503433001 S1-01503678001 S1-01503434001 S1-01503560001 S1-01503437001 S1-01503436001 S1-01503435001 S1-01503425001 S1-01503589001 S1-01503414001 S1-01503413001 S1-01503297004 S1-01503263001 S1-01503264001 S1-01503265001 S1-01503520001 S1-01503403001 S1-01503404001 S1-01503260001 S1-01503552001 S1-01503261001 S1-01503553001 S1-01503696001 S1-01503523001 S1-01503521001 S1-01503522001 S1-01503555001 S1-01503255001 S1-01503556001 S1-01503256001 S1-01503254001

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

H29B15UABCA H29B17UABCA H29B18UABCA H29B18UABCA H29B18UABCA H29B18UABCB H29B20UABCA H29B22UABCA H29B24UABCA H29B24UABCA H29B24UABCB H29B26UABCA H29B28UABCB H29B28UABCA H29B30UABCA H29B30UDBVA H29B30UABCA H29B30UDBLA H29B33UDBVA H29B33UDBFA H29B33UDBLA H29B33UABCA H29B35UDBLA H29B35UDBVA H29B35UABHA H29B35UABCA H29A383CBCA H29A383DBVA H29A383DBLA H29A423CBCA H29A423DBLA H29A423DBVA H29A423DBFA H29A473CBCA H29A473DBLA H29A473DBVA H29A503DBLA H29A503CBCA H29A503DBVA H29A543CBCA H29A543DBLA H29A563DBFA H29A563DBLA H29A563DBVA H29A563CBCA H29A623DBVA H29A623CBCA H29A623DBFA H29A623DBLA

15,700 17,200 18,300 18,300 18,300 18,300 20,420 22,600 24,200 24,200 24,200 26,700 28,800 28,833 29,800 29,800 29,860 30,000 32,800 33,000 33,100 33,621 35,100 35,100 35,500 35,681 37,600 38,344 38,580 42,400 42,800 42,800 42,930 47,130 47,583 47,730 50,300 50,425 50,711 54,200 54,600 56,600 56,600 56,600 56,700 60,700 61,100 61,100 61,100

208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 208/230-1-60 208/230-3-60 460-3-60 265-1-60 208/230-1-60 208/230-1-60 460-3-60 208/230-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-3-60 208/230-1-60 460-3-60 208/230-1-60 208/230-3-60 575-3-60 208/230-3-60 460-3-60 208/230-1-60 460-3-60 208/230-1-60 575-3-60 208/230-3-60

RLA LRA EER

SUCT HT ID (S)

DISCH HT ID (D)

OVALL WIRE HT (H) CCH CONN

6.7 7.2 7.4 7.4 7.4 7.4 8.6 9.6 9.6 9.6 9.6 10.9 11.8 11.8 12.4 4.1 12.4 8.5 4.6 3.7 9.5 13.5 9.6 4.9 13 14.4 15.2 5.2 10.0 15.2 10.4 5.9 9.2 18.7 11.9 6.3 12.5 19.2 6.2 20.5 13.7 5.8 14.0 7.0 22 7.5 24 6.1 14.9

5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 5/8 3/4 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

13.5 13.531 13.25 13.53 13.531 13.531 13.5 13.5 13.7 14.031 14.031 14.031 14.031 13.7 14.531 14.531 14.2 14.531 14.531 14.531 14.531 14.2 14.2 14.2 14.5 14.2 16.4 16.4 16.4 17.4 16.4 17.7 16.4 17.6 17.7 17.7 17.7 17.6 17.688 17.6 17.688 17.688 17.688 17.688 17.6 17.688 17.6 17.688 17.688

48.0 48.0 48.0 48.0 48 48 60.0 60.0 61.0 61 61 68.0 73 73.0 82 40 82.0 78 40 32 78 82.0 78.0 40.0 90.0 86.0 87.0 54.0 110.0 105.0 130.0 58.0 52.0 135.0 130.0 64.0 137.0 135.0 69.0 135.0 137 62.0 150.0 75.0 135.0 75.0 147.0 62.0 150.0

10.6 10.7 10.7 10.7 10.7 10.7 10.7 10.7 10.9 10.9 10.9 10.9 10.9 10.9 11.0 10.8 11.0 10.9 10.8 10.7 10.9 11.0 10.9 10.9 10.7 10.9 11.4 11.6 11.7 11.7 11.6 11.5 11.6 11.6 11.6 11.7 11.6 11.5 11.5 11.5 11.6 11.5 11.5 11.7 11.5 11.5 11.4 11.6 11.6

11.2 13.25 11.234 11.234 12.766 12.766 12.7 12.7 11.7 13.484 13.484 11.734 13.484 11.7 12.234 12.234 12.2 12.234 12.234 12.234 12.234 12.2 12.2 12.2 13.7 12.2 15.5 14.0 14.0 15.2 14.0 15.2 14.0 17.3 15.2 15.2 15.2 15.2 15.25 17.3 15.25 15.25 15.25 15.25 17.3 15.25 17.3 15.25 15.25

N/A 2.875 2.875 2.875 2.875 2.875 2.8 2.8 N/A 2.875 2.875 2.875 2.875 N/A 2.875 2.875 N/A 2.875 2.875 2.875 2.875 N/A N/A N/A 2.8 N/A 3.8 N/A N/A 2.9 N/A N/A N/A 3.8 N/A N/A N/A 3.8 3.812 3.8 3.812 3.812 3.812 3.812 3.8 3.812 3.8 3.812 3.812

Y N N Y Y Y W N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y W Y W Y Y Y Y Y Y W Y Y Y W Y W Y Y Y Y W Y W Y Y

Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q S S S S S S S S S S S S S

*RUN CAP

SHIP WT. (LBS.)

MLP

30/370 64 $ 817.72 30.0/370 63 815.36 30.0/370 63 825.44 30/370 63 746.62 30.0/370 75 809.51 30.0/370 64 809.21 30-370 65 782.54 30-370 65 843.36 35/370 67 863.98 35.0/370 65.5 826.93 35.0/370 65.5 851.42 35.0/370 68 864.04 35.0/370 67.1 856.90 35/370 67.5 866.45 40.0/370 72 820.72 N/A 73 1108.15 40/370 72 901.79 N/A 69.1 1097.17 N/A 70 1261.93 0 70.5 1098.90 N/A 70 1147.20 45/370 72 909.70 N/A 71 1188.32 N/A 71 1189.10 N/A 74 956.96 45/370 73.5 924.93 45.0/370 96.5 1238.61 N/A 96.5 1436.20 N/A 96.5 1436.20 45/370 104.5 1246.56 N/A 98.5 1444.80 N/A 98.5 1447.95 N/A 98.5 1551.89 55-370 109.5 1293.17 N/A 99 1560.09 N/A 99 1560.09 N/A 104.5 1652.00 55-370 109.5 1502.41 N/A 104.5 1693.73 60-370 109.5 1435.34 N/A 104.5 2647.86 N/A 109.5 1870.29 N/A 109.5 1880.25 N/A 110.0 1869.35 60-370 109.5 1451.71 N/A 109.5 1702.00 60-370 109.5 1525.11 N/A 109.5 1831.90 N/A 109.5 1843.04

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

9


hemrichelectric.com

info@hemrichelectric.com

BRISTOL COMPRESSORS

H82J Series Bristol Benchmark R410A SOURCE 1 PART NO. NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW

S1-01504124001 S1-01504076004 S1-01504077004 S1-01504154001 S1-01504151001 S1-01504125001 S1-01504078004 S1-01504180001 S1-01504184001 S1-01504129001 S1-01504127001 S1-01504128001 S1-01504126001 S1-01504133001 S1-01504131001 S1-01504132001 S1-01504130001 S1-01504079004 S1-01504181001 S1-01504185001 S1-01504080004 S1-01504182001 S1-01504186001

BRISTOL MODEL NO.

CAPACITY

V-PH-HZ

RLA

LRA

EER

SUCT

DISCH

OVALL HT

CCH

*RUN CAP

SHIP WT.

MLP

H82J18BABCA H82J193ABCA H82J223ABCA H82J223DBLA H82J223DBVA H82J26BABCA H82J273ABCA H82J273DBLA H82J273DBVA H82J283DBFA H82J283DBLA H82J283DBVA H82J28BABCA H82J323DBFA H82J323DBLA H82J323DBVA H82J32BABCA H82J353ABCA H82J353DBLA H82J353DBVA H82J373ABCA H82J373DBLA H82J373DBVA

18,000 18,900 22,300 22,400 22,400 26,200 27,000 26,900 26,900 28,000 28,000 28,000 28,100 31,600 31,600 31,600 31,700 34,800 34,600 34,600 37,600 37,400 37,400

230/208-1-60 230/208-1-60 230/208-1-60 230/200-3-60 460/380-3-60 230/208-1-60 230/208-1-60 230/200-3-60 460/380-3-60 575-3-60 230/200-3-60 460/380-3-60 230/208-1-60 575-3-60 230/200-3-60 460/380-3-60 230/208-1-60 230/208-1-60 230/200-3-60 460/380-3-60 230/208-1-60 230/200-3-60 460/380-3-60

7.4 8 9.9 7.3 3.6 11.6 11.8 7.7 3.9 3.1 7.8 3.9 13 3.5 8.8 4.4 13.6 14.5 10.2 5.3 15.7 11.7 5.8

43 43 54 71 30 74 74 68 35 28 68 34 74 28 68 34 88 84 88 44 84 90 44

10.1 10.2 10.3 10 10.3 10.5 10.5 10.5 10.4 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.2 10.4 10.2 10.2

0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75

0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5

14.25 14.25 14.75 14.25 14.25 14.75 14.75 15 15 15 15 15 14.75 15 15 15 15 15.594 15.594 15.594 15.594 15.594 15.594

Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

35/370 35/370 35/370 N/A N/A 40/370 40/370 N/A N/A N/A N/A N/A 40/370 N/A N/A N/A 45/370 40/440 N/A N/A 45/440 N/A N/A

62 62 64.5 66 66 72.5 72.5 72 72 72 72 72 72.5 72 72 72 74.5 91.5 88.5 88.5 91.5 88.5 88.5

$ 925.89 833.29 912.15 1079.75 1079.75 991.71 926.00 1101.60 1101.60 1109.53 1109.53 1109.53 997.09 1138.19 1113.14 1138.19 1025.75 1017.25 1167.00 1167.00 1019.50 1187.11 1187.11

* NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

H89 Series R410A SOURCE 1 PART NO. S1-01503897001

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

SUCT

DISCH

OVALL HT (H)

CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

H89B283ABCA

28,900

208/230-1-60

13.5

83

9.8

0.75

0.5

14.09

Y

35.0/440

73.5

$1079.95

* NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

T21 Series Bristol Benchmark TwinSingle R22 SOURCE 1 PART NO. S1-01503996001 S1-01503997001 S1-01503982001

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

T21J205CBCA T21J265CBCA T21J334CBCA

20,200 25,300 28,900

208/230-1-60 208/230-1-60 208/230-1-60

RLA LRA EER 8.1 10.2 13.5

60 76 83

10.9 10.9 9.8

SUCT

DISCH

OVALL HT (H)

CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

0.75 0.75 0.75

0.5 0.5 0.5

16.031 15.75 16.031

Y Y Y

30.0/440 40.0/440 35.0/440

82 82 82

$1755.32 1755.32 1713.90

* NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

10

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BRISTOL RECIPROCATING COMPRESSORS

T29 Series

SOURCE 1 PART NO. S1-01503295001 S1-01503296001

BRISTOL MODEL NO.

CAPACITY BTUH

V-PH-HZ

T29A464BBCA T29A544BBCA

30,100/47,000 33,000/53,500

208/230-1-60 208/230-1-60

RLA

LRA

EER

ID

SUCT HT (S)

7.0/17.8 88/130 22.4/11.3 7/8 9.8/22.0 80/142 22.5/10.8 7/8

15.25 15.25

DISCH OVALL ID HT (D) HT (H) CCH 1/2 1/2

3.31 3.31

17.69 17.69

Y Y

WIRE CONN

*RUN CAP

QC 55/370 SCREW 55/370

SHIP WT. (LBS.)

MLP

110 110

$1536.04 1705.76

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

11


hemrichelectric.com

info@hemrichelectric.com

BRISTOL COMPRESSOR ACCESSORIES

Premier Compressor Blankets (For Noise Suppression) Features: • Vinyl w/1/2 inch foam backing

• 1 inch wide velcro fasteners • Die cut for proper fit SOURCE 1 PART NO. S1-01004620000 S1-01004621000 S1-01004664000 S1-01005499000 S1-01005669000 S1-01005827000 S1-01006662000

• UL recognized materials

FITS COMPRESSOR MODEL NO.

MLP

H23 & H24B – ALL MODELS H29B – ALL MODELS H20, H21C & R – 4 TO 6-1/3 TONS H20, H21C & R – UP TO 3-1/2 TONS H23 & H24A 383 AND SMALLER H23 & H24A 423 AND LARGER H29A – ALL MODELS

$ 62.56 57.93 58.45 61.40 81.44 64.83 169.42

Scott Mfg. “Acousticap” Compressor Blankets (For Noise Suppression) Features: • Superior noise reduction (NRC = 85)

• Molded closed cell foam shell w/acoustical liner

SOURCE 1 PART NO.

• Snap fasteners for ease of installation (some modification may be required) • UL recognized materials

FITS COMPRESSOR MODEL NO.

S1-01005977000 S1-01005979000 S1-01005980000

MLP

H23, H24, H25, 27A & 87A – ALL MODELS H20 & H21C – ALL MODELS / H20 & H21R 483 AND SMALLER H23, H24, H25 & H26B – ALL MODELS

$71.77 66.35 61.07

Compressor Mounting Isolators SOURCE 1 PART NO.

DIMENSIONS C D

DUROMETER

A

B

60

0.41

0.66

S1-02612357000*

0.50

1.50

E

MLP

1.00

N/A

* USE WITH SPRING (S1-02920421000) & WASHER (S1-02811969000)

Crankcase Heaters (CCH) For Bristol Application

SOURCE 1 PART NO. S1-02533326000 S1-02532895000 S1-02519840700 S1-02519961701 S1-02515525702 S1-02517043700 S1-02533474240 S1-02533474480 S1-02533474575 S1-02531959000 S1-02531960000 S1-02531958000

TYPE

FIG.

LENGTH OF ELEMENT

VOLTS

WATTS

USED WITH COMPRESSOR

MLP

INSERTION INSERTION WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND

1 1 2 2 2 2 2 2 2 2 3 3

N/A N/A 29 - 36 24 - 30 27 - 33 41 - 47 29 - 36 29 - 36 29 - 36 22 - 26 22 - 26 22 - 26

100 - 600 100 - 600 120 240 240 240 240 480 575 240 480 575

30* 47* 90 45 54 75 90 90 90 70 80 70

ALL EXCEPT H20 & H21 ALL EXCEPT H20, H21 & H29 MEASURE CIRCUMFERENCE OF COMPRESSOR MEASURE CIRCUMFERENCE OF COMPRESSOR MEASURE CIRCUMFERENCE OF COMPRESSOR MEASURE CIRCUMFERENCE OF COMPRESSOR ALL H20 & H21 OVER 5 TONS ALL H20 & H21 OVER 5 TONS ALL H20 & H21 OVER 5 TONS ALL H20 & H21 UP TO 5 TONS ALL H20 & H21 UP TO 5 TONS ALL H20 & H21 UP TO 5 TONS

$ 23.24 126.90 26.41 28.23 27.62 22.63 42.30 45.84 42.24 84.91 86.77 49.94

*If in doubt, use 47 watts. NOTE: For proper application of insertion type CCH, heat conductive compound S1-01301502000 (available from SOURCE 1) or equivalent must be used.

12

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BRISTOL COMPRESSOR ACCESSORIES

High Torque Start Components Note: Compressor starting characteristics are definite. These high torque starting components are listed for Bristol compressors only. Do not attempt to cross reference to other manufacturers.

START CAPACITOR COMPRESSOR MODEL NO.

MFD/VAC

H23A303ABCA H23A323ABCA H23A353ABCA H23A353ABHA H23A383ABCA H23A423ABCA H23B153ABHA H23B173ABCA H23B17SABCA H23B18SABCA H23B19QABKA H23B223ABCA H23B223ABHA H23B22SABCA H23B243ABCA H23B263ABCA H23B26QABKA H23B283ABHA H23B28SABCA H23B303ABCA H23B35QABKA H24A383ABCA H24A423ABCA H24B20QABKA H24B26QABHA

145-175/250 145-175/250 145-175/250 145-175/250 145-175/250 145-175/250 88-108/250 88-108/330 161-193/250 161-193/250 88-108/250 88-108/330 88-108/250 88-108/250 88-108/250 88-108/330 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 145-175/250 145-175/250 88-108/250 88-108/250

SOURCE 1 PART NO. S1-02425071700 S1-02425071700 S1-02425071700 S1-02425071700 S1-02425071700 S1-02425071700 S1-02425191700 S1-02425191700 S1-02425075700 S1-02425075700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425071700 S1-02425071700 S1-02425191700 S1-02425191700

MLP $17.23 17.23 17.23 17.23 17.23 17.23 18.42 18.42 17.27 17.27 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 17.23 17.23 18.42 18.42

COLD PICK-UP

DROP OUT

COIL VOLTS

180 - 195 180 - 195 N/A 223 - 252 N/A N/A 180 - 195 162 - 175 224 - 252 224 - 252 180 - 195 180 - 195 180 - 195 180 - 195 162 - 175 162 - 175 162 - 175 180 - 195 180 - 195 162 - 175 N/A N/A N/A 180 - 195

40 - 105 40 - 105 N/A 60 - 121 N/A N/A 40 - 105 40 - 90 40 - 90 40 - 90 40 - 105 40 - 105 60 - 130 40 - 105 55 - 115 40 - 90 55 - 115 40 - 105 40 - 105 55 - 115 N/A N/A N/A 60 - 130

375 375 N/A 420 N/A N/A 375 332 332 332 375 375 450 375 383 332 383 375 375 383 N/A N/A N/A 450

START RELAY CONTACT RATING AMP 35 35 N/A 35 N/A N/A 35 50 35 35 35 35 35 35 35 50 35 35 35 35 N/A N/A N/A 35

SOURCE 1 PART NO. S1-02425189700 S1-02425189700 N/A S1-02425218700 N/A N/A S1-02425189700 S1-02425392700 S1-02425916700 S1-02425916700 S1-02425189700 S1-02425189700 S1-02426047000 S1-02425189700 S1-02426031000 S1-02425392700 S1-02426031000 S1-02425189700 S1-02425189700 S1-02426031000 N/A N/A N/A S1-02426047000

MLP $40.94 40.94 N/A 80.77 N/A N/A 40.94 46.41 50.00 50.00 40.94 40.94 47.73 40.94 40.87 46.41 40.87 40.94 40.94 40.87 N/A N/A N/A 47.73

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

13


hemrichelectric.com

info@hemrichelectric.com

Scrolltech Compressor Nomenclature

14

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SCROLL COMPRESSORS

HCM, HDM & HRM Series - Scroll For Air Conditioning & Heat Pump Application Features: • Scroll technology • High efficiency-up to 11.6 EER • Inherent motor protection • Low vibration & noise

• Painted shell • Refrigerant — HCFC-22 • Wire connections - see chart – Q = Quick connect – S = Screw

SOURCE 1 PART NO.

DANFOSS MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

S1-01503314004 S1-01502989004 S1-01502990004 S1-01502991004 S1-01503123004 S1-01503110004 S1-01502911004 S1-01502912004 S1-01503102004 S1-01502793004 S1-01502993004 S1-01502994004 S1-01503409004 S1-01503410004 S1-01502914004 S1-01502915004 S1-01502916004 S1-01503406004 S1-01502995004 S1-01502997004 S1-01503662004 S1-01503663004 S1-01503239004 S1-01502998004 S1-01502999004 S1-01503517004 S1-01503519004 S1-01503518004 S1-01503412004 S1-01503416004 S1-01503417004

HDM023T1LP6 HDM037T2LP6 HDM037T4LP6 HDM037T7LP6 HDM042T7LP6 HDM042U2LP6 HDM045T2LP6 HDM045T4LP6 HDM045U4LP6 HDM048T1LP6 HDM048T4LP6 HDM048T7LP6 HDM058U2LP6 HDM058U4LP6 HDM058T2LP6 HDM058T4LP6 HDM058T7LP6 HRM058T1LP6 HDM060T2LP6 HDM060T7LP6 HCM072T4LC6 HCM072T7LC6 HCM075T2LC6 HCM075T2LP6 HCM075T4LP6 HCM081T2LC6 HCM081T7LC6 HCM081T4LC6 HCM094T2LC6 HCM094T4LC6 HCM094T7LC6

22,300 36,600 36,700 36,700 41,600 42,000 44,500 44,500 44,800 47,500 47,500 47,500 56,500 56,600 57,400 57,400 57,400 57,500 59,400 59,400 72,300 72,300 74,800 74,800 75,300 81,500 81,560 81,600 94,500 94,500 94,500

208/230-1-60 230/208-3-60 460-3-60 575-3-60 575-3-60 208/230-3-60 230/208-3-60 460-3-60 460-3-60 208/230-1-60 460-3-60 575-3-60 230/208-3-60 460-3-60 230/208-3-60 460-3-60 575-3-60 208/230-1-60 230/208-3-60 575-3-60 460-3-60 575-3-60 208/230-3-60 230/208-3-60 460-3-60 208/230-3-60 575-3-60 460-3-60 208/230-3-60 460-3-60 575-3-60

11.5 11.4 6.2 5.0 5.7 14.1 12.8 6.4 6.4 24.4 7.1 5.6 15.5 8.9 16.0 8.0 6.4 28.9 16.0 6.4 8.4 6.7 18.9 18.9 9.5 21.8 9.0 11.0 25.6 12.8 10.2

64 90.0 45.0 36.0 36.0 90.0 93.0 47.0 46.5 140.0 55.0 44.0 125.0 66.5 125.0 67.0 50.0 160.0 125.0 50.0 73 60.0 146.0 146.0 73.0 184.0 73.0 90.0 40.0 20.0 16.0

10.9 11.1 11.1 11.0 11.1 11.0 11.4 11.3 11.3 11.0 11.4 11.4 11.3 11.3 11.4 11.4 11.4 11.2 11.4 11.3 11.5 11.5 11.4 11.4 11.6 11.7 11.7 11.7 11.7 11.7 11.7

+ + +

+ + + + + + +

+

+ + + + + + +

SUCT ID HT (S) 3/4 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 0.875 0.875 7/8 7/8 7/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8

9.5 10.7 10.7 10.7 10.7 10.2 12.2 12.2 11.7 12.2 12.2 12.2 12.3 12.3 12.8 12.8 12.3 12.3 12.8 12.3 12.25 12.25 12.2 12.8 12.8 13.8 13.8 13.8 14.3 14.3 14.3

• Foot print - 7.5 x 7.5 • No crankcase heater

DISCH ID HT (D)

OVALL HT (H)

CCH

WIRE CONN.

*RUN CAP

SHIP WT. (LBS.)

MLP

1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 0.5 0.5 1/2 1/2 1/2 7/8 7/8 7/8 7/8 7/8 7/8

15.3 16.7 16.7 16.7 16.7 16.2 18.2 18.2 17.7 18.2 18.2 18.2 18.6 18.6 19.1 19.1 18.6 18.6 19.1 18.6 18.567 18.567 18.6 19.1 19.1 20.1 20.1 20.1 21.1 21.1 21.1

N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N

Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q S S Q Q S S S S S S

35.0/370 N/A N/A N/A N/A N/A N/A N/A N/A 50/440 N/A N/A N/A 80/370 N/A N/A N/A 55/440 N/A N/A — — N/A N/A N/A N/A N/A N/A N/A N/A N/A

69.8 90 69 68 67 68 75 75 74 87 75 75 80 80 97 80 81 87 81 88 — — 98 90 95 100 100 100 102 102 102

$ 950.39 1169.36 1169.36 1169.36 1187.74 1312.69 1306.18 1306.18 1389.24 1174.03 1483.95 1432.05 1860.66 1882.63 1550.10 1699.21 1461.93 1472.64 1738.37 1667.76 1891.77 1891.77 1880.72 1753.58 1900.16 2395.23 3350.89 2277.90 3305.12 3240.14 3289.83

14.3 15.7 15.7 15.7 15.7 15.2 17.1 17.1 16.6 17.1 17.1 17.1 17.5 17.5 18.0 18.0 17.5 17.5 18.0 17.5 17.52 17.52 17.5 18.0 18.0 19.0 19.0 19.0 14.3 14.3 14.3

+ Suitable for 50 Hz. operation * NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

15


hemrichelectric.com

info@hemrichelectric.com

SCROLL COMPRESSORS

HRM Series For Air Conditioning & Heat Pump Application

NEW

SOURCE 1 PART NO.

DANFOSS MODEL NO.

S1-01503719004 S1-01504082004 S1-01503700004 S1-01503701004 S1-01503702004 S1-01503699004 S1-01503704004 S1-01503705004 S1-01503706004 S1-01503703004 S1-01503708004 S1-01503707004 S1-01503709004 S1-01503657004 S1-01503711004 S1-01503710004 S1-01503715004 S1-01503714004 S1-01503718004 S1-01503679004 S1-01503722004 S1-01503723004 S1-01503724004 S1-01503972004 S1-01503725004 S1-01503726004 S1-01503727004 S1-01503729004 S1-01503730004 S1-01503731004 S1-01503728004 S1-01503730004

HRM051U2LP6 HRM034U1LP6 HRM038U2LP6 HRM038U4LP6 HRM038U7LP6 HRM038U1LP6 HRM040U2LP6 HRM040U4LP6 HRM040U7LP6 HRM040U1LP6 HRM042U4LP6 HRM042U2LP6 HRM042U7LP6 HRM042U1LP6 HRM045U2LP6 HRM045U1LP6 HRM047U2LP6 HRM047U1LP6 HRM051U1LP6 HRM054U1LC6 HRM054U2LP6 HRM054U4LP6 HRM054U7LP6 HRM058U1LC6 HRM058U2LP6 HRM058U4LP6 HRM058U7LP6 HRM060U2LP6 HRM060U4LP6 HRM060U7LP6 HRM060U1LP6 HRM060U4LP6

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

SUCT

DISCH

OVALL HT (H)

† CCH

*RUN CAP

SHIP WT. (LBS.)

34,000 38,000 38,000 38,000 38,400 39,800 39,800 39,800 40,800 41,700 42,000 42,000 42,300 44,600 45,200 46,600 47,500 51,200 53,700 53,700 53,700 53,700 57,700 57,800 57,800 57,800 59,700 59,700 59,700 59,750 N/A

230-3-60 208/230-1-60 230-3-60 460-3-60 575-3-60 230-1-60 230-3-60 460-3-60 575-3-60 230-1-60 460-3-60 208/230-3-60 575-3-60 208/230-1-60 208/230-3-60 230-1-60 208/230-3-60 230-1-60 230-1-60 208/230-1-60 230-3-60 460-3-60 575-3-60 208/230-1-60 230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 460-3-60

16.7 16.7 13.4 6.4 5.4 19.5 13.4 6.4 6.0 21.0 7.1 14.1 5.8 21.0 16.0 23.0 16.0 24.4 25.6 25.0 17.3 7 8.4 28.8 17.3 9.6 7.4 17.9 9.6 7.4 28.8 9.6

120 96.7 89 45 38 105 89 45 38.0 115 45 95 38 115.0 115.0 115 115 120 150 150.0 123 53 70 145 123 70 53 123 70 53 145 70

26 11.0 11.2 10.0 N/A 11.3 11.1 10.0 11.3 11.3 11.0 N/A N/A 11.3 11.1 11.2 N/A 11.3 40 11.5 27 11 13.1 11.4 27 15 11.5 11.5 15 N/A 11.4 N/A

7/8 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 3/4 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S 7/8 S

1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S 1/2 S

17.16 15.53 15.53 15.53 15.53 15.53 15.53 15.53 15.53 15.53 15.53 15.53 15.53 15.53 16.53 15.53 16.53 16.53 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16

BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-40W BAND-50W BAND-50W BAND-50W BAND-40W BAND-40W BAND-40W BAND-40W BAND-50W BAND-40W BAND-50W BAND-50W BAND-50W

45.0/ 55.0/370 60.0/370 60.0/370 60.0/370 60.0/370 60.0/370 80.0/370 80.0/370 -

87 70 73 73 72 73 73 73 72 73 73 69 72 66 75 76 75 76 87 87 87 87 87 87 87 87 86 87 82 86 82

MLP $1494.00 1269.92 1290.24 1290.24 1280.25 1212.37 1322.69 1396.78 1396.78 1160.27 1283.16 1421.62 1421.62 1159.99 1528.16 1391.37 1426.83 1391.00 1386.90 1593.95 1701.30 1701.30 1680.49 1535.00 1715.44 1699.21 1811.85 1738.37 1760.90 1660.00 1546.28 1760.90

† Not included with compressor. * NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

16

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SCROLL COMPRESSORS

HLH, HLJ & HRH Series SOURCE 1 PART NO.

DANFOSS MODEL NO.

S1-01503993000 S1-01503994000 S1-01503995000 S1-01503953004 S1-01503991000 S1-01503992000 S1-01503732004 S1-01503672004 S1-01503735004 S1-01503743004 S1-01503737004 S1-01503739004 S1-01503675004 S1-01503674004 S1-01503740004 S1-01503960004 S1-01503961004 S1-01503742004 S1-01503744004 S1-01503741004 S1-01503676004 S1-01503749004 S1-01503750004 S1-01503751004 S1-01503753004 S1-01503755004 S1-01503757004 S1-01503754004 S1-01503886004 S1-01503887004

HLJ072T2LC6 HLJ072T4LC6 HLJ072T7LC6 HLJ083T2LC6 HLJ083T4LC6 HLJ083T7LC6 HRH032U2LP6 HRH036U2LP6 HRH036U7LP6 HRH044U4LP6 HRH038U2LP6 HRH038U7LP6 HRH041U4LP6 HRH041U2LP6 HRH041U7LP6 HRH040U1LP6 HRH040U2LP6 HRH044U2LP6 HRH044U7LP6 HRH044U1LP6 HRH051U2LP6 HRH051U7LP6 HRH054U1LP6 HRH054U2LP6 HRH054U7LP6 HRH056U2LP6 HRH056U7LP6 HRH056U1LP6 HLH068T4LC6 HLH068T7LC6

CAPACITY BTUH

31,500 36,300 36,300 36,900 37,900 37,900 41,200 41,300 41,300 41,500 42,000 44,300 44,300 44,400 51,400 51,400 54,500 54,500 54,500 56,200 56,200 56,900 68,700 68,700

SUCT

DISCH

OVALL HT (H)

† CCH

208/230-3-60 460-3-60

7/8 7/8

1/2 1/2

17.16 17.16

BAND-50W BAND-50W

208/230-3-60 460-3-60 575-3-60 208/230-3-60 208/230-3-60 575-3-60 380/415-3-50 208/230-3-60 N/A 460-3-60 208/230-3-60 575-3-60 208/230-1-60 208/230-3-60 208/230-3-60 575-3-60 208/230-1-60 208/230-3-60 575-3-60 208/230-1-60 208/230-3-60 575-3-60 208/230-3-60 575-3-60 208/230-1-60 460-3-60 575-3-60

7/8 7/8 7/8 3/4 3/4 3/4 7/8 3/4 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

17.16 17.16 17.16 15.53 15.53 15.53 17.16 15.53 15.53 17.16 17.16 17.16 16.53 16.53 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16 17.16

BAND-70W BAND-70W BAND-70W BAND-40W BAND-40W BAND-40W BAND-50W BAND-40W BAND-40W BAND-50W BAND-50W BAND-50W BAND-40W BAND-40W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-50W BAND-70W BAND-70W

V-PH-HZ

RLA

12.8 14.1 5.4 8.6 14.7 6 8.3 16 6.4 21 16 16.7 6.7 24.3 17.6 7.4 29 17.3 7.5 17.3 8 30.1 12.2 8.6

LRA

95 95 38 60 115 40 60 120 42 115 115 120 42 150 120 53 145 123 53 123 53 145 87 62

EER

9.8 9.8 10.2 9.4 10 10 10.2 10.2 10.2 10.3 10.3 10.2 10.2 10.3 10.4 10.4 10.6 10.3 10.3 10.2 10.2 10.5 10.9 10.9

*RUN CAP

N/A N/A N/A N/A N/A N/A N/A N/A N/A 60.0/370 N/A N/A N/A 70.0/370 N/A N/A 80.0/370 N/A N/A N/A N/A 80.0/370 N/A N/A

SHIP WT. (LBS.)

MLP

72 73 72 87 72 73 87 87 87 76 73 87 87 87 87 87 87 87 87 87 87 87 87 87

$4817.69 2330.46 3360.78 3014.58 2412.68 3429.66 1452.61 1554.09 1374.88 1734.60 1542.24 1497.15 1663.91 1658.53 1495.73 1399.94 1583.50 1668.11 1734.60 1410.79 1756.57 1918.67 1638.26 1908.40 1784.30 1946.57 1978.68 1692.71 2075.39 2075.39

† Not included with compressor. * NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

COMMERCIAL SCROLL COMPRESSORS

SM Series SOURCE 1 PART NO. S1-SM115-3QAI S1-SM115-4QAI S1-SM125-3QAI S1-SM125-4QAI S1-SM175-3QAI S1-SM175-4QAI S1-SM185-3QAI S1-SM185-4QAI

CAPACITY (TONS)

V-PH-HZ

SUCT

DISCH

MLP

9 9 10 10 14 14 15 15

230-3-60 460-3-60 230-3-60 230-3-60 230-3-60 460-3-60 230-3-60 460-3-60

1-3/8 1-3/8 1-3/8 1-3/8 1-5/8 1-5/8 1-5/8 1-5/8

7/8 7/8 7/8 7/8 1-1/8 1-1/8 1-1/8 1-1/8

$3339.28 3339.28 3594.65 3594.65 4164.28 4164.28 4517.85 4517.85

* NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

17


hemrichelectric.com

info@hemrichelectric.com

COMPRESSOR ACCESSORIES

High Torque Start Components Note: Compressor starting characteristics are definite. These high torque starting components are listed for Danfoss compressors only. Do not attempt to cross reference to other manufacturers.

START CAPACITOR COMPRESSOR MODEL NO.

DANFOSS COMPRESSOR MODEL NO.

MFD/VAC

H20C233ABCA H20C303ABCA H20C343ABCA H20C373ABCA H20C403ABCA H20C423ABCA H20R453ABCA H20R483ABCA H20R583ABCA H20R603ABCA H21C343ABCA H21R453ABCA H21R483CBCA

HDM023T1LP6 HDM030T1LP6 HDM034T1LP6 HDM037T1LP6 HDM040T1LP6 HDM042T1LP6 HDM045T1LP6 HDM048T1LP6 HDM058T1LP6 HDM060T1LC6 HDM034U1LP6 HDM045U1LP6 N/A

88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 88-108/250 161-193/250

SOURCE 1 PART NO. S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425075700

MLP

COLD PICK-UP

DROP OUT

$18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 17.27

162 - 175 180 - 195 180 - 195 180 - 193 180 - 193 180 - 193 180 - 195 180 - 195 180 - 195 180 - 195 180 - 195 132 - 148 132 - 148

40 - 90 40 - 105 60 - 130 40 - 90 40 - 90 40 - 90 60 - 130 60 - 130 60 - 130 60 - 130 60 - 130 40 - 90 40 - 90

START RELAY CONTACT COIL RATING VOLTS AMP 332 375 450 332 332 332 450 450 450 450 450 332 332

35 35 35 50 50 50 35 35 35 35 35 35 35

SOURCE 1 PART NO. S1-02425189700 S1-02425189700 S1-02426047000 S1-02425389700 S1-02425389700 S1-02425389700 S1-02426047000 S1-02426047000 S1-02426047000 S1-02426047000 S1-02426047000 S1-02425035000 S1-02425035000

MLP $40.94 40.94 47.73 46.35 46.35 46.35 47.73 47.73 47.73 47.73 47.73 56.28 56.28

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

18

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

19


hemrichelectric.com

20

info@hemrichelectric.com

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

21


hemrichelectric.com

info@hemrichelectric.com

COPELAND SCROLL COMPRESSORS

ZP Series SOURCE 1 PART NO.

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

S1-01503973004 S1-01503974004 S1-01503975004 S1-01503943004 S1-01503944004 S1-01503932004 S1-01503933004 S1-01503934004 S1-01503949004 S1-01503946004 S1-01503947004 S1-01503948004 S1-01503966004 S1-01503967004 S1-01503968004 S1-01503969004 S1-01503936004

ZP137KCE-TF5 ZP137KCE-TFD ZP137KCE-TFE ZP42K5E-TF5 ZP42K5E-TFD ZP51K5E-PFV-830 ZP51K5E-TF5-130 ZP51K5E-TFD-130 ZP54K5E-PFV-830 ZP54K5E-TF5 ZP54K5E-TFD ZP54K5E-TFE ZPS26K4E-PFV-230 ZPS35K4E-PFV-230 ZPS35K4E-TF5-230 ZPS35K4E-TFD-460 ZPS51K4E-TFD

138,000 138,000 138,000 41,900 41,900 51,000 51,500 51,500 54,000 54,300 54,200 54,000 26,500 36,800 36,800 35,800 52,000

208/230-3-60 460-3-60 575-3-60 200/230-3-60 460-3-60 208/230-1-60 200/230-3-60 460-3-60 208/230-1-60 200/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-1-60 200/230-3-60 460-3-60 460-3-60

RLA LRA

EER

SUCTION ID HT (S)

50 273 10.9 1.375 20.7 118 10.9 1.375 16.4 100 10.8 1.375 15.3 83.1 10.3 0.875 6.9 41 10.3 0.875 29.4 134 10.5 0.875 17.8 110 10.7 0.875 8.6 52 10.7 0.875 29.3 134 10.5 0.875 17.4 110 10.7 0.875 8.6 52 10.7 0.875 6.5 38.9 10.6 0.875 15.7 70 9.9 0.75 18.6 96 10.45 0.75 15 88 10.5 0.75 6.8 44 10.3 0.75 10 62 10.5 0.875

4.81 4.81 4.81 11.73 11.73 11.73 11.73 11.73 11.73 11.73 11.73 11.73 11.06 11.06 11.06 10.94 11.69

DISCH OVALL ID HT (D) HT (H) 0.875 19.73 0.875 19.73 0.875 19.73 0.5 16.6 0.5 16.6 0.5 16.6 0.5 16.6 0.5 16.6 0.5 16.6 0.5 16.6 0.5 16.6 0.5 16.6 0.5 15.09 0.5 15.09 0.5 15.09 0.5 14.98 0.5 16.134

20.99 20.99 20.99 17.17 17.17 17.17 17.17 17.17 17.17 17.17 17.17 17.17 16.754 16.12 16.12 16.004 18.16

* RUN CAP N/A N/A N/A N/A N/A 70.0/370 N/A N/A 80.0/370 N/A N/A N/A 40.0/370 45.0/370 N/A N/A N/A

WIRE SHIP WT. CONN. (LBS.) S S S Q Q Q Q Q Q Q Q Q Q Q Q Q Q

130 130 130 68.2 68.2 75.8 72.8 72.8 75.8 72.4 72.8 72.8 73 75 66 66 85

MLP $4770.00 4770.00 4770.00 1801.55 1801.55 1990.33 2082.98 2083.11 1975.00 2098.11 2098.11 2098.11 1807.22 1984.34 2308.00 2308.00 2533.06

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

22

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COPELAND SCROLL COMPRESSORS

ZR22K thru ZR81K Series For Air Conditioning & Heat Pump Application Features: • High efficiency & reliability • Internal line break motor protection • Baked enamel finish • Refrigerant — HCFC-22 • High efficiency - up to 11.5 EER SOURCE 1 PART NO. S1-01503527004 S1-01503527004 S1-01502721004 S1-01502970004 S1-01502971004 S1-01502792004 S1-01502972004 S1-01502761004 S1-01502689704 S1-01502737004 S1-01502738004 S1-01502764004 S1-01502690704 S1-01502740004 S1-01502741004 S1-01502773004 S1-01502790004 S1-01502791004 S1-01503497004 S1-01502975004 S1-01503400004 S1-01503401004 S1-01503402004 S1-01502620704 S1-01503365004 S1-01503366004 S1-01503399004 S1-01502645004 S1-01502646704 S1-01502647704 S1-01502648704 S1-01502694004 S1-01502695004 S1-01502696004 S1-01503179004

COPELAND CAPACITY MODEL / B/M NO. BTUH ZR22K3-PFV-930 ZR22K4-PFV-930 ZR26K3-PFV-930 ZR26K3-TF5-930 ZR26K3-TFD-930 ZR28K3-PFV-930 ZR28K3-TF5-930 ZR30K3-PFV-930 ZR34K3-PFV-930 ZR34K3-TF5-930 ZR34K3-TFD-930 ZR36K3-PFV-930 ZR40K3-PFV-930 ZR40K3-TF5-930 ZR40K3-TFD-930 ZR42K3-PFV-930 ZR47KC-TF5-930 ZR47KC-TFD-930 ZR48K3-PFV-935 ZR54K3-PFV-950 ZR54K3-TF5-950 ZR54K3-TFD-930 ZR54K3-TFE-930 ZR57K3-PFV-950 ZR57K3-TF5-930 ZR57K3-TFD-930 ZR57K3-TFE-930 ZR61K3-PFV-950 ZR61K3-TF5-950 ZR61K3-TFD-950 ZR61K3-TFE-950 ZR72KC-TF5-950 ZR72KC-TFD-930 ZR72KC-TFE-930 ZR81KC-TFD-950

22,100 22,000 26,000 26,200 26,200 28,500 28,500 30,500 34,000 34,000 34,000 36,500 40,000 40,000 40,000 42,100 47,000 47,000 49,800 54,000 54,000 54,000 54,000 57,000 57,200 57,200 57,100 61,200 61,000 61,000 61,000 72,100 72,100 72,100 81,000

V-PH-HZ 208/230-1-60 208/230-1-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 230/200-3-60 208/230-1-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 200/230-3-60 460-3-60 208/230-1-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 200/230-3-60 460-3-60 575-3-60 208/230-1-60 230/200-3-60 460-3-60 575-3-60 230/200-3-60 460-3-60 575-3-60 460-3-60

• Foot print 7.5 x 7.5 • Wire connections: – Q = Quick connect – S = Screw • Suitable for 50 Hz. operation SUCTION DISCH OVALL RLA LRA EER ID HT (S) ID HT (D) HT (H)

*RUN CAP

11.4 12.1 13.6 8.6 4.3 15.0 10.0 15.0 17.2 11.4 5.7 18.4 20.0 13.9 6.4 20.4 14.3 7.2 22.1 28.0 19.3 7.5 6.4 32.1 19.3 10.0 7.9 32.1 19.3 10.0 7.9 20.7 10.0 8.2 12.0

40/370 40/370 40/370 N/A N/A 45/370 N/A 45/370 50/370 N/A N/A 50/370 55/370 N/A N/A 60/370 N/A N/A 60/440 80/370 N/A N/A N/A 80/370 N/A N/A N/A 80/370 N/A N/A N/A N/A N/A N/A N/A

56.0 54.0 67.0 55.0 27.0 72.5 63.0 73.0 88.0 77.0 39.0 95.0 104.0 88.0 44.0 109.0 91.0 46.0 137.0 169.0 123.0 49.0 40.0 169.0 123.0 62.0 50.0 169.0 123.0 62.0 62.0 156.0 70.0 54.0 100.0

11.0 10.8 11.2 11.2 11.2 11.1 11.2 11.1 11.2 11.4 11.4 11.2 11.2 11.4 11.4 11.3 11.0 11.0 11.5 11.1 11.1 11.1 11.1 11.5 11.5 11.5 11.4 11.3 11.5 11.5 11.5 11.5 11.5 11.5 11.5

3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

10.3 9.6 10.3 10.3 10.3 10.3 10.3 11.2 10.4 11.2 11.2 11.2 10.9 11.7 11.7 11.7 12.3 12.3 12.3 12.5 11.7 11.7 11.7 13.3 11.7 11.7 11.7 13.3 13.3 13.3 13.3 12.5 12.5 12.5 11.6

1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4

14.1 13.3 14.1 14.1 14.1 14.1 14.1 15.1 14.2 15.1 15.1 15.1 14.8 15.6 15.6 15.6 16.1 16.1 16.1 16.9 16.1 16.1 16.1 17.8 16.1 16.1 16.1 17.8 17.8 17.8 17.8 16.9 16.9 16.9 16.3

15.1 14.9 15.1 15.1 15.1 15.1 15.1 16.1 15.2 16.1 16.1 16.1 15.7 16.6 16.6 16.6 17.1 17.1 17.1 18.0 17.2 17.2 17.2 18.9 17.2 17.2 17.2 18.9 18.9 18.9 18.9 18.0 18.0 18.0 17.6

WIRE SHIP WT. CONN. (LBS.) Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q S Q Q Q S Q Q Q S S S S Q Q Q S

59 60 61 61 61 61 61 63 65 65 65 66 67 67 67 68 69 69 80 94 84 84 84 94 92 92 92 94 94 94 94 86 86 86 87

MLP $1049.28 1049.28 1054.24 1338.42 1539.08 1126.63 1428.03 1182.03 1191.78 1546.10 1656.64 1256.62 1325.40 1586.09 1556.72 1346.10 1665.61 1665.61 1465.17 1550.84 1810.78 1885.78 1780.98 1619.41 1810.78 1810.78 1810.78 1744.84 1815.78 1852.20 1886.76 1963.16 1963.16 1963.16 2480.76

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

23


hemrichelectric.com

info@hemrichelectric.com

COPELAND SCROLL COMPRESSORS

ZRT1 & ZZ Series - Dual For Air Conditioning & Heat Pump Application Features: • High efficiency & reliability • Internal inherent protection—ZRT models, or external electronic protection—ZZ models (Kriwan module P/N S102533361000) SOURCE 1 PART NO. S1-01502707004 S1-01502708004 S1-01502709004 S1-01503150004 S1-01503156004 S1-01503157004 S1-01503158004 S1-01503390004 S1-01503391004 S1-01503392004 S1-01503394004 S1-01503395004 S1-01503396004 S1-01503159004 S1-01503160004 S1-01503161004 S1-01503162004 S1-01503418004 S1-01503419004 S1-01503420004

• • • •

Baked enamel finish Refrigerant — HCFC-22 Foot print: 21.5 x 7.5 High efficiency - up to 11.5 EER

SUCT HT (S)

COPELAND MODEL/BM NO.

CAPACITY BTUH

VOLTAGE

RLA

LRA

EER

ID

ZRT144KC-TF5-950 ZRT144KC-TFD-930 ZRT144KC-TFE-930 ZRT162KC-TFD-930 ZZ18M3-TWC-952 ZZ18M3-TWD-952 ZZ18M3-TWE-952 ZRT188KC-TF5-950 ZRT188KC-TFD-950 ZRT188KC-TFE-950 ZRT250KC-TF5-950 ZRT250KC-TFD-950 ZRT250KC-TFE-950 ZZ24M3-TWC-952 ZZ24M3-TWD-952 ZZ24M3-TWE-952 ZZ28M3-TWD-952 ZZ32M3-TWD-970 ZZ32M3-TWE-970 ZZ32M3-TWC-970

144,200 144,200 144,200 162,000 177,800 177,800 177,800 185,900 185,900 185,900 248,100 248,100 248,100 251,000 251,000 251,000 281,600 309,000 309,000 309,000

230/200-3-60 460-3-60 575-3-60 380/450-3-50 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 460-3-60 460-3-60 575-3-60 208/230-3-60

41.4 20.0 16.4 24.0 62.4 13.9 10.1 32.1 16.4 12.0 42.0 19.2 13.8 37.4 18.4 15.2 18.3 25.0 19.9 47.1

312.0 140.0 108.0 181/202 189.0 94.0 74.0 195.0 95.0 80.0 239.0 125.0 80.0 278.0 127.0 100.0 127 158.0 125.0 350.0

11.5 11.5 11.5 11.5 11.2 11.2 11.2 11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4

1-1/8 1-1/8 1-1/8 1-1/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8 1-5/8

17.9 17.9 17.9 17.8 15.5 15.5 15.5 5.4 5.4 5.4 6.5 6.5 6.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5

DISCH. ID HT (D) 3/4 3/4 3/4 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8 1-3/8 1-1/8 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8 1-3/8

17.7 17.7 17.7 17.8 20.8 20.8 20.8 7.6 7.6 7.6 8.6 8.6 8.6 20.8 20.8 20.8 20.8 20.8 20.8 20.8

OVALL HT (H)

SHIP WT. (LBS.)

MLP

18.8 18.8 18.0 18.0 22.4 22.4 22.4 20.5 20.5 20.5 21.5 21.5 21.5 22.4 22.4 22.4 22.7 22.4 22.4 22.4

200 200 200 207 473 475 478 367 342 347 362 300 300 496 496 496 510 510 475 497

$ 5103.16 5078.52 4928.80 5533.61 9821.39 9623.52 9656.06 8665.63 8643.00 8495.72 9726.65 9507.37 9607.73 10441.52 10596.70 8903.77 10826.20 11638.02 11558.60 11559.79

ZR94K thru ZR190K Series For Air Conditioning & Heat Pump Application Features: • High efficiency & reliability • Internal line break motor protection • Baked enamel finish • Refrigerant — HCFC-22 • High efficiency - up to 11.5 EER • Foot print 7.5 x 7.5 SOURCE 1 PART NO. S1-01502923004 S1-01502924004 S1-01502925004 S1-01503165004 S1-01503169004 S1-01503177004 S1-01503248004

24

• Wire connections: – Q = Quick connect – S = Screw • Suitable for 50 Hz. operation • Uses standard 3GS mineral oil

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

ZR94KC-TF5-950 ZR94KC-TFD-950 ZR94KC-TFE-950 ZR125KC-TF5-950 ZR125KC-TFD-950 ZR125KC-TFE-950 ZR144KC-TFD-950

94,000 94,000 94,000 124,500 124,500 124,500 142,800

230/200-3-60 460-3-60 575-3-60 230/200-3-60 460-3-60 575-3-60 460-3-60

RLA LRA EER 32.1 16.4 12.0 42.0 19.2 13.8 19.6

195.0 95.0 80.0 239.0 125.0 80.0 125.0

11.5 11.5 11.2 11.5 11.5 11.5 11.5

SUCTION ID HT (S) 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8 1-3/8 1-3/8

STOCKED NON STOCKED

4.6 4.6 4.6 4.8 4.8 4.8 4.8

DISCH OVALL WIRE SHIP WT. ID HT (D) HT (H) CONN. (LBS.) 7/8 7/8 7/8 7/8 7/8 7/8 7/8

18.3 18.3 18.3 19.7 19.7 19.7 19.7

19.5 19.5 19.5 20.8 20.8 20.8 20.8

S S S S S S S

132 132 132 141 141 141 141

MLP $3877.20 3819.96 3821.97 4035.17 4042.20 4042.20 4614.05

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COPELAND SCROLL COMPRESSORS

ZR12/19M3 Series Universal Replacement for Air Conditioning & Heat Pump Application Features: • High efficiency & reliability • Baked enamel finish • Refrigerant — HCFC-22 • Foot print - 8.65 x 8.65 • Screw type wire connections SOURCE 1 PART NO. S1-01502917004 S1-01502966004 S1-01502918004 S1-01502919004 S1-01503151004 S1-01503154004 S1-01503152004 S1-01503153004

• High efficiency - up to 11.5 EER • 24V Solid state motor protector module (P/N S1-02533361000) • Includes module & Rotolock adapter connections

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

ZR12M3-TWC-961 ZR12M3-TW7-961 ZR12M3-TWD-961 ZR12M3-TWE-961 ZR16M3-TWC-961 ZR16M3-TW7-961 ZR16M3-TWD-961 ZR16M3-TWE-961

125,000 125,000 125,000 125,000 154,300 154,300 154,300 154,300

230/208-3-60 380-3-60 460-3-60 575-3-60 208/230-3-60 380-3-60 460-3-60 575-3-60

38.5 26.0 18.8 15.7 47.1 28.7 25.0 19.9

228.0 151.0 127.0 100.0 350.0 195.0 158.0 125.0

11.4 11.4 11.4 11.4 11.4 11.4 11.4 11.4

SUCTION ID HT (S) 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8

12.6 12.6 12.6 12.6 12.6 12.6 12.6 12.6

DISCH ID HT (D) 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

OVALL HT (H)

SHIP WT. (LBS.)

MLP

21.2 21.2 21.2 21.2 21.4 21.4 21.4 21.4

205 205 205 205 211 211 211 211

$4522.91 4268.77 4841.29 4700.27 5012.44 4771.18 5012.44 4875.72

19.6 19.6 19.6 19.6 19.8 19.8 19.8 19.8

COPELAND RECIPROCATING COMPRESSORS

RR Series For Air Conditioning & Heat Pump Application Features: • Inherent motor protection • Baked enamel finish • Low vibration & noise • Centrifugal oil pump • Foot print - 8.0 x 4.81 SOURCE 1 PART NO. S1-01502081707 S1-01503476000 S1-01503477000

• • • •

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

RR12K1-PFV-901 RR16K1-PFV-971 RR17K1-PFV-900

11,200 15,500 18,300

208/230-1-60 208/230-1-60 208/230-1-60

Refrigerant — HCFC-22 Quick connect wire connections Suitable for 50 Hz. operation High efficiency - up to 8.8 EER

RLA LRA EER 7.1 9.5 10.4

35.0 43.3 48.2

SUCTION STUB CONN HT (S)

8.8 8.6 8.3

1/2 1/2 1/2

10.8 11.1 11.3

DISCH ID

OVALL HT (H)

*RUN CAP

SHIP WT. (LBS.)

MLP

5/16 3.8 3.8

11.5 11.75 12.0

20/370 25/370 30/370

49 51 52

$1008.55 1052.48 931.86

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

25


hemrichelectric.com

info@hemrichelectric.com

COPELAND RECIPROCATING COMPRESSORS

CRKQ Series For Air Conditioning & Heat Pump Application Features: • Internal line break motor protection • Baked enamel finish • Low vibration & noise • Centrifugal oil pump

SOURCE 1 PART NO. S1-01503444005 S1-01503448005 S1-01503449005 S1-01503450005 S1-01503451005 S1-01503452005 S1-01503453005 S1-01503457005 S1-01503458005 S1-01503459005 S1-01503460005 S1-01503461005 S1-01503462005

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

CR22KQ-PFV-980WB CR33KQ-PFV-980WB CR33KQ-TF5-980WB CR33KQ-TFD-980WB CR34KQ-PFV-980WB CR34KQ-TF5-980WB CR34KQ-TFD-980WB CR37KQ-PFV-980WB CR37KQ-TF5-980WB CR37KQ-TFD-980WB CR41KQ-PFV-980WB CR41KQ-TF5-980WB CR41KQ-TFD-980WB

22,600 32,700 32,500 32,500 34,800 34,500 34,500 38,000 37,700 36,400 42,100 34,900 34,900

208/230-1-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 230/200-3-60 460-3-60

• • • • •

Refrigerant — HCFC-22 Foot print - 7.5 x 7.5 Quick connect wire connections Suitable for 50 Hz. operation High efficiency - up to 10.4

RLA LRA EER

SUCTION DISCH OVALL ID HT (S) ID HT (H) CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

12.9 17.3 12.0 5.6 19.9 12.5 5.8 22.5 14.3 5.6 23.9 15.3 7.7

5/8 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4

30/370 40/370 N/A N/A 40/370 N/A N/A 35/440 N/A N/A 40/440 N/A N/A

68 70 70 70 72 72 72 75 75 66 76 76 76

$ 782.56 1023.95 1109.98 1201.64 1014.99 1128.44 1128.44 1037.24 1298.80 1376.23 1048.07 1352.69 1352.69

54.0 75.8 65.0 32.5 83.5 66.0 35.0 93.0 74.0 39.0 95.4 82.0 41.0

10.0 10.1 10.3 10.3 10.1 10.2 10.4 10.1 10.2 10.4 10.1 10.2 10.2

13.9 14.4 14.4 14.4 14.7 14.7 14.7 14.9 14.9 14.9 15.2 15.2 15.2

3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8

14.2 14.7 14.7 14.7 14.9 14.9 14.9 15.2 15.2 15.2 15.4 15.4 15.4

Y Y Y Y Y Y Y Y Y Y Y Y Y

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

CR5 Series For Air Conditioning & Heat Pump Application Features: • Internal line break motor protection • Baked enamel finish • Low vibration & noise • Centrifugal oil pump

SOURCE 1 PART NO. S1-01502130705 S1-01502400705 S1-01502131705 S1-01502401705 S1-01502132705 S1-01501606705 S1-01501596705 S1-01501597705

• • • • •

High efficiency - 10.3 EER Refrigerant — HCFC-22 Foot print - 7.5 x 7.5 Quick connect wire connections Suitable for 50 Hz. operation

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

EER

SUCTION DISCH OVALL ID HT (S) ID HT (H) CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

CRP5-0450-PFV-970 CRT5-0450-TF5-970 CRP5-0450-TF5-970 CRT5-0450-TFD-970 CRP5-0450-TFD-970 CRN5-0500-PFV-970 CRN5-0500-TF5-970 CRN5-0500-TFD-970

58,300 55,500 58,600 55,500 58,600 62,700 61,400 61,400

208/230-1-60 230/200-3-60 230/200-3-60 460-3-60 460-3-60 208/230-1-60 230/200-3-60 460-3-60

30.7 19.6 19.6 10.4 10.4 34.3 21.4 9.6

135.0 105.0 105.0 55.0 55.0 142.0 115.0 50.0

10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3

7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8

45/440 N/A N/A N/A N/A 55/440 N/A N/A

88 88 88 88 94 88 88 88

$1549.67 1368.50 1679.10 1753.47 1705.76 1389.30 1788.60 1769.31

15.9 15.9 15.9 15.9 15.9 16.0 16.0 16.0

1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

16.3 16.3 16.3 16.3 16.3 16.5 16.5 16.5

Y Y Y Y Y Y Y Y

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

26

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COPELAND RECIPROCATING COMPRESSORS

CR6 Series For Air Conditioning & Heat Pump Application Features: • Internal line break motor protection • Baked enamel finish • Low vibration & noise • Centrifugal oil pump

SOURCE 1 PART NO. S1-01502760004 S1-01502314701 S1-01502437701 S1-01502438701 S1-01502422701 S1-01502423701 S1-01502424701 S1-01502315701 S1-01502415709 S1-01502415710

COPELAND MODEL / B/M NO.

CAPACITY BTUH

V-PH-HZ

CR28K6-PFV-960 CR35K6-PFV-960 CR35K6-TF5-960 CR35K6-TFD-960 CR38K6-PFV-960 CR38K6-TF5-960 CR38K6-TFD-960 CR42K6-PFV-960 CR42K6-TF5-960 CR42K6-TFD-960

28,200 34,900 34,900 34,900 38,200 38,200 38,200 41,900 41,900 41,900

208/230-1-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60 230/200-3-60 460-3-60

• • • • •

High efficiency - up to 11.0 Refrigerant — HCFC-22 Foot print - 7.5 x 7.5 Quick connect wire connections Suitable for 50 Hz. operation

LRA

EER

SUCTION ID HT (S)

15.3 75.0 18.0 96.0 11.4 75.0 4.8 40.0 19.0 105.0 11.9 85.0 5.9 42.0 20.4 102.0 14.0 91.0 6.4 42.0

10.8 10.9 11.0 11.0 10.8 11.0 11.0 10.9 11.0 11.0

3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4

RLA

11.6 12.5 12.5 12.5 12.8 12.8 12.8 13.1 13.1 13.1

DISCH ID

OVALL HT (H)

CCH

*RUN CAP

SHIP WT. (LBS.)

MLP

1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

13.9 14.4 14.4 14.4 14.7 14.7 14.7 15.0 15.0 15.0

Y Y Y Y Y Y Y Y Y Y

35/370 40/370 N/A N/A 40/440 N/A N/A 40/440 N/A N/A

74 80 80 80 80 80 80 80 80 80

$ 802.91 988.31 1628.83 1423.32 1004.91 1365.41 1370.28 934.34 1431.34 1403.21

*NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

27


hemrichelectric.com

info@hemrichelectric.com

COPELAND COMPRESSOR ACCESSORIES

High Torque Start Components Note: Compressor Starting Characteristics Are Definite. These High Torque Starting Components Are Listed For Copeland Compressors Only. Do Not Attempt To Cross Reference To Other Manufacturers.

START CAPACITOR COMPRESSOR MODEL NO.

*MFD/VAC

CRC2-0175-PFV CRG3-0250-PFV CRH3-0275-PFV CRJ3-0300-PFV CRK3-0325-PFV CRL3-0350-PFV CRM3-0400-PFV CRN5-0500-PFV CRP5-0450-PFV CR28K6-PFV CR32KF-PFV CR35K6-PFV CR38K6-PFV CR42K6-PFV ZR22K3-PFV ZR26K3-PFV ZR28K3-PFV ZR30K3-PFV ZR34K3-PFV ZR36K3-PFV ZR40K3-PFV ZR42K3-PFV ZR46K3-PFV ZR47KC-PFV ZR49K3-PFV ZR54K3-PFV ZR57K3-PFV ZR61Z3-PFV

64-77/250 161-193/250 189-227/330 189-227/330 189-227/330 189-227/330 189-227/330 260-302/250 189-227/330 88-108/330 88-108/330 189-227/330 189-227/330 189-227/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 270-324/330 270-324/330 270-324/330 270-324/330 270-324/330 270-324/330

SOURCE 1 PART NO. N/A S1-02425075700 S1-02425215700 S1-02425215700 S1-02425215700 S1-02425215700 S1-02425215700 SEE NOTE 1 S1-02425215700 S1-02425191700 S1-02425191700 S1-02425215700 S1-02425215700 S1-02425215700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425390700 S1-02425390700 S1-02425390700 S1-02425390700 S1-02425390700 S1-02425390700

MLP N/A $17.27 25.56 25.56 25.56 25.56 25.56 N/A 25.56 18.42 18.42 25.56 25.56 25.56 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 28.57 28.57 28.57 28.57 28.57 28.57

COLD PICK-UP

DROP OUT

COIL VOLTS

186-215 223-252 180-195 223-252 N/A N/A 223-252 223-252 223-252 162-175 162-175 180-195 223-252 180-193 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175 162-175

40-90 60-121 40-105 60-121 N/A N/A 60-121 60-121 60-121 40-90 40-90 40-105 60-121 55-115 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90

332 375 375 375 N/A N/A 420 420 420 336 336 375 420 383 332 336 336 336 336 336 336 336 336 336 336 336 336 336 336

START RELAY CONTACT RATING (AMP) 35 35 35 35 N/A N/A 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35

SOURCE 1 PART NO. S1-02425391700 N/A S1-02425189700 N/A N/A N/A S1-02425218700 S1-02425218700 S1-02425218700 S1-02425184000 S1-02425184000 S1-02425189700 S1-02425218700 S1-02426035000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000 S1-02425184000

MLP $74.71 N/A 40.94 N/A N/A N/A 80.77 80.77 80.77 59.39 59.39 40.94 80.77 40.78 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39 59.39

NOTE 1 – Use (2) 130-154MFD / 330 Volt capacitors (P/N #S1-02425220000) wired in parallel.

28

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COPELAND COMPRESSOR ACCESSORIES

Crankcase Heaters (CCH) For Copeland Application

SOURCE 1 PART NO. S1-02532895000 S1-02519840700 S1-02528381700 S1-02527413000 S1-02519961701 S1-02515525702 S1-02532781000 S1-02517043700 S1-02533474240 S1-02533474480 S1-02533474575 S1-02531959000 S1-02531960000 S1-02531958000

TYPE

FIG.

LENGTH OF ELEMENT

VOLTS

WATTS

USED WITH COMPRESSOR

MLP

INSERTION (ROUND) WRAP AROUND INSERTION (D TYPE) WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND

1 2 1 2 2 2 2 2 2 2 2 2 3 3

N/A 29 - 36 N/A 22 - 26 24 - 30 27 - 33 34 - 37 41 - 47 29 - 36 29 - 36 29 - 36 22 - 26 22 - 26 22 - 26

100 - 600 120 240 - 600 240 240 240 240 240 240 480 575 240 480 575

47 90 40 42 45 54 70 75 90 90 90 70 80 70

ALL WITH ROUND WELL ALL BR, ZR94 ALL WITH “D” SHAPED WELL ALL RE ALL CR ALL CR ZR12 MEASURE CIRCUMFERENCE OF COMPRESSOR ZR94 ZR94 ZR94 ZR UP TO 6-1/3 TONS ZR UP TO 6-1/3 TONS ZR UP TO 6-1/3 TONS

$126.90 26.41 156.90 61.77 28.23 27.62 41.36 22.63 42.30 45.84 42.24 84.91 86.77 49.94

NOTE:For proper application of insertion type CCH heat conductive compound S1-01301502000 (available from SOURCE 1) or equivalent MUST be used.

Premier Mfg. Compressor Blankets For Noise Suppression Features: • Vinyl w/1/2 inch foam backing • 1 inch wide velcro fasteners • Die cut for proper fit • UL recognized materials

SOURCE 1 PART NO.

FITS COMPRESSOR MODEL NO.

MLP

CR42K6 & LARGER CRM & LARGER ZR - 4 TO 6-1/3 TONS ZR UP TO 3-1/2 TONS BR, ZR94 CR38K6 & SMALLER

$71.58 81.44 58.45 61.40 64.83 57.93

S1-01004580000 S1-01005669000 S1-01004664000 S1-01005499000 S1-01005827000 S1-01004621000

Scott Mfg. “Acousticap” Compressor Blankets For Noise Suppression Features: • Superior noise reduction (NRC = 85) • Molded closed cell foam shell w/ acoustical liner • Snap fasteners for ease of installation (some modification may be required) • UL recognized materials

SOURCE 1 PART NO. S1-01005977000 S1-01005978000 S1-01005979000 S1-01005980000

FITS COMPRESSOR MODEL NO.

MLP

CRN & LARGER ALL CR_ _ K6 CRK THRU CRM, ZR40 & SMALLER CRH & SMALLER, RE

$71.77 64.70 66.35 61.07

Compressor Mounting Isolators SOURCE 1 PART NO. S1-02807772000 S1-02809519000 S1-02810581000

DUROMETER

A

65 45 40

0.72 0.72 0.75

DIMENSION C D 0.44 0.44 0.44

1.25 1.25 1.63

E

MLP

0.94 0.94 1.13

$0.79 1.38 1.73

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

29


hemrichelectric.com

info@hemrichelectric.com

COPELAND SEMI-HERMETIC COMPRESSORS

For Air Conditioning And Heat Pump Applications Copeland Semi-Hermetic Compressors Feature: – All new parts except for core and crankshaft – Solid state control module for motor protector (not included) – Spring mounted – Painted housings - gloss black – Internal unloading components included when applicable – One year limited warranty All 4R, 6R, 4D, AND 6D compressors are remanufactured as follows: – Core exchange or charge is required – Unit is completely disassembled – Housings and heads are completely cleaned and all rust is removed – Crankshafts are replated and milled to original specifications The following components are replaced with new factory specification parts: – High pressure relief valve – Pistons, piston rings, piston rods – Bearings – Motor – Valve plates, valves – Oil pump – Terminal kit – Reassembled in environmentally controlled room – Leak and run tested – Evacuated and charged with 10-15 PSI dry nitrogen – All ports are sealed for shipment – Completely painted in gloss black – Individually boxed, including required gaskets and wiring instructions. Identified as York Remanufactured Copeland Compressor. A survey of users, to determine common industry practice, indicates that most contractors prefer to disconnect the existing compressors electrical box and reinstall it on the new replacement unit. This eliminates the need to rewire the entire unit. Also, other standard components such as service and unloader valves, crankcase heaters, and mounting springs rarely fail and therefore it is to your customers advantage to reuse the existing components. Therefore the following components are not included with York remanufactured Copeland compressors but may be purchased individually (see following pages). – Suction and discharge service valves – Terminal box with cover – Terminal parts kit (external) – Control module (motor protector) – Terminal board for control module – Crankcase heater – Capacity control (unloading) valves – Mounting springs The following components are included but may also be purchased individually (see following pages). – Cylinder head with capacity control piston – Valve plate kit – Gaskets – Sight glass kit – Oil pump kit

30

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COPELAND SEMI-HERMETIC COMPRESSORS

Replacement Parts For Remanufactured Compressors SUCTION AND DISCHARGE SERVICE VALVES W/GASKET SOURCE 1 COMPRESSOR PART NO. USED WITH S1-02208706000 S1-02636508000 S1-02208708000 S1-02208709000 S1-02208707000

2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D

TERMINAL BOX, PARTS AND ACCESSORIES SOURCE 1 COMPRESSOR PART NO. USED WITH S1-02531493000

2D, 3D, 4R, 6R, 4D, 6D

S1-02531710000

2D, 3D, 4R, 6R, 4D, 6D

DESCRIPTION

MLP

1-1/8 I.D. SWEAT, BOLT ON 1-1/8 I.D. SWEAT, (ROTOLOK) 1-3/8 I.D. SWEAT, BOLT ON 1-3/8 I.D. SWEAT, (ROTOLOK) 2-1/8 I.D. SWEAT, BOLT ON

$451.25 453.30 311.76 290.54 653.20

DESCRIPTION

CONTROL MODULE (MOTOR PROTECTOR) AND TERMINAL BOARD SOURCE 1 COMPRESSOR PART NO. USED WITH S1-02533277000 S1-02535318000

2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D

COIL, SOLENOID (UNLOADING) SOURCE 1 PART NO. S1-057341 *S1-02527939000

$472.23

343.94

DESCRIPTION

MLP

CONTROL MODULE 24 VOLT CONTROL MODULE 120/240 VOLT

$439.91 485.89

CAPACITY CONTROL (UNLOADING) VALVE W/GASKET SOURCE 1 COMPRESSOR PART NO. USED WITH S1-02208704000

MLP

KIT TERMINAL PARTS INCLUDES: (2) BAKELITE INSULATORS (1) FIBER INSULATOR (3) JUMPER BAR EXTENSIONS (BRASS) (6) LUGS 0-14 CU (STL.) (9) KEPS NUTS (5) JUMPER BARS (BRASS) KIT TERMINATION INCLUDES: TERMINAL BOX, COVER, CONTROL MODULE TERMINAL BOARD, AND TERMINAL PARTS KIT

2D, 3D, 4R, 6R, 4D, 6D

DESCRIPTION

MLP

SPORLAN

$254.70

COMPRESSOR USED WITH

DESCRIPTION

MLP

2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D

24 VOLT, EMERSON CLIMATE TECHNOLOGIES 120 VOLT, EMERSON CLIMATE TECHNOLOGIES

$ 56.15 255.98

* PREFERRED MOUNTING HARDWARE SOURCE 1 PART NO. S1-02913662000 S1-02920278000

COMPRESSOR USED WITH *

DESCRIPTION

MLP

2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D

BLUE SPRING ISOLATOR (MOTOR END) GREEN SPRING ISOLATOR (COMPR. END)

$7.30 3.69

* SPRINGS MUST BE REPLACED WITH SAME COLOR

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

31


hemrichelectric.com

info@hemrichelectric.com

COPELAND SEMI-HERMETIC COMPRESSORS

Replacement Parts For Remanufactured Compressors CRANKCASE HEATERS, SCREW-IN, SEE NOTE SOURCE 1 COMPRESSOR PART NO. USED WITH S1-02518611001 S1-02518611002 S1-02518611003 S1-02518611005

2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D

DESCRIPTION

MLP

120V,100 WATT, DIRECT IMERSION TYPE 1/2 - 14 THD. 240V,100 WATT, DIRECT IMERSION TYPE 1/2 - 14 THD. 480V,100 WATT, DIRECT IMERSION TYPE 1/2 - 14 THD. 380V,100 WATT, DIRECT IMERSION TYPE 1/2 - 14 THD.

$188.30 191.47 187.14 205.13

NOTE: For proper installation of threaded CCH, thread sealant such as Seal-Loc (see p. 335) should be used. VALVE PLATE W/GASKETS INCLUDES: HEAD GASKET & VALVE PLATE GASKET SOURCE 1 PART NO. S1-02630917000 S1-02630918000 OIL PUMP W/GASKET SOURCE 1 PART NO. S1-02630920000

GASKETS SOURCE 1 PART NO.

COMPRESSOR USED WITH 2D, 3D, 4R, 6R, 4D, 6D

COMPRESSOR USED WITH

MLP

4RH,4RK, 6RK, 6RP 4RR

$484.40 741.04

MLP

SIGHT GLASS W/GASKET SOURCE 1 PART NO.

COMPRESSOR USED WITH

MLP

$623.89

S1-02630919000

2D, 3D, 4R, 6R, 4D, 6D

$136.82

TORQUE SPECIFICATIONS COMPRESSOR USED WITH

DESCRIPTION

MLP

S1-02811930000

2D, 3D, 4R, 6R, 4D, 6D

FOR 1-1/8 & 1-3/8 BOLT ON SERVICE VALVE

$11.57

S1-02811932000

2D, 3D, 4R, 6R, 4D, 6D

FOR 1-1/8 & 1-3/8 ROTOLOK SERVICE VALVE

2.41

S1-02811931000 S1-02811928000 S1-02813114000 S1-02813115000 S1-02811927000 S1-02813121000 S1-02813122000

2D, 3D, 4R, 6R, 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 4D, 6D 4D, 6D 2D, 3D, 4R, 6R, 4D, 6D 4D, 6D 4D, 6D

FOR 2-1/8 BOLT ON SERVICE VALVE CAPACITY CONTROL VALVE (UNLOADING) VALVE PLATE TO BODY (2-11/16 DIA. PISTON) VALVE PLATE TO BODY (2-15/16 DIA. PISTON)) OIL PUMP VALVE PLATE TO HEAD (WITHOUT UNLOADING) VALVE PLATE TO HEAD (WITH UNLOADING)

4.56 26.68 39.34 39.34 11.45 14.44 15.21

32

STOCKED NON STOCKED

APPLICATION SERVICE VALVE, SUCTION W/1/2 INCH BOLTS SERVICE VALVE, SUCTION W/5/8 INCH BOLTS SERVICE VALVE, DISCHARGE CAPACITY CONTROL VALVE CRANKCASE HEATER CRANKCASE HEATER WELL CYLINDER HEAD OIL PUMP SIGHT GLASS

TORQUE (IN/LB) 500 950 500 425 450 400 400 250 40

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

PANASONIC ROTARY COMPRESSORS

Panasonic Industrial Compressors SOURCE 1 PART NO. S1-01503980007 S1-01503981007

COPELAND MODEL / B/M NO.

MLP

2K15S236UUA 2J29S236B1A

$664.51 739.92

Compressor Blankets for Panasonic Compressors For Noise Suppression SOURCE 1 PART NO. S1-01006758000

FITS COMPRESSOR MODEL NO.

MLP

S1-01503981007 (COPELAND MODEL / B/M NO. 2J29S236B1A)

$63.47

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

33


hemrichelectric.com

info@hemrichelectric.com

—NOTES—

34

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TECEMSEH COMPRESSORS

HVAC SERVICE PARTS

35 Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

36

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TECUMSEH ROTARY & RECIPROCATING COMPRESSORS

RK Series For Air Conditioning & Heat Pump Application Features: •High efficiency •Low vibration & noise •Rotary design •Painted shell •Refrigerant — HCFC-22 •Foot print — 3 leg on 6.9 bolt circle

SOURCE 1 PART NO. S1-01502656707 S1-01502394007 S1-01502654707 S1-01503563000

MODEL NO.

CAPACITY BTUH

V-PH-HZ

RKA5490EXD RKA5512EXD RKA5515EXC RKA5515EXD

9,100 11,700 12,500 15,500

208/230-1-60 208/230-1-60 240/220-1-50 208/230-1-60

RLA LRA 3.8 4.8 5.2 6.4

20.0 26.3 32.0 38.0

SUCTION ID HT (S) 1/2 1/2 5/8 5/8

9.4 9.6 9.8 N/A

ID

DISCH HT (D)

5/16 5/16 5/16 5/16

10.7 11.1 11.9 N/A

OVALL HT (H)

SHIP. WT. (LBS.)

CCH

RUN CAP

MLP

11.3 11.6 12.5 N/A

26 27 31 N/A

N N N N

25/370 25/370 25/370 25/370

$512.70 606.09 716.44 743.63

AW Series For Air Conditioning & Heat Pump Application Features: • External line break motor protection • Painted shell

SOURCE 1 PART NO. S1-01502369002 S1-01502366002 S1-01502346002 S1-01502371002 S1-01502664701

• Low vibration & noise • Refrigerant — HCFC-22 • Footprint — 7.5 x 7.5

MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

DWG NO

SUCTION ID HT (S)

AW5524E AW5522E AW5522E AW5528E AWF5528EXN

20,700 21,300 21,300 27,000 28,000

240/220-1-50 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60

9.7 10.2 10.2 12.8 13.0

54.0 60.0 60.0 73.0 73.0

AW1 AW1 AW1 AW3 AW1

1/2 3/4 3/4 5/8 3/4

12.2 12.2 12.2 13.1 12.2

DISCH ID

SHIP WT. (LBS.)

CCH

RUN CAP

MLP

5/16 3/8 3/8 3/8 3/8

64 59 59 64 64

N Y N Y Y

35/370 25/370 25/370 35/370 35/370

$726.87 732.00 705.71 836.02 889.19

AV Series For Air Conditioning & Heat Pump Application Features: • External line break motor protection • Painted shell • Low vibration & noise • Refrigerant — HCFC-22 • Foot print — 7.5 x 7.5 SOURCE 1 PART NO. S1-01502677701 S1-01502003002 S1-01501640701 S1-01501648701 S1-01501649002

MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

DWG NO

AVA5535EXN AVC5535EXN AVA5538EXT AVA5538EXG AVC5538EXN

35,200 35,900 38,400 38,400 38,900

208/230-1-60 208/230-1-60 230/200-3-60 460-3-60 208/230-1-60

15.8 14.9 10.8 5.3 16.5

88.0 86.7 73.4 37.7 97.6

AV2 AV2 AV2 AV2 AV2

SUCTION ID HT (S) 7/8 7/8 7/8 7/8 7/8

13.0 12.8 12.3 12.3 12.8

DISCH ID

OVALL HT (H)

SHIP WT. (LBS.)

CCH

1/2 1/2 1/2 1/2 1/2

15.2 15.0 15.0 15.0 15.0

83 83 86 86 86

N Y N Y N

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

RUN CAP

MLP

40/370 $ 865.35 45/370 987.86 N/A 1141.48 N/A 1140.18 45/440 1096.52

37


hemrichelectric.com

info@hemrichelectric.com

TECUMSEH ROTARY & RECIPROCATING COMPRESSORS

AG Series For Air Conditioning & Heat Pump Application Features: • External line break motor protection • Painted shell

SOURCE 1 PART NO. S1-01501277002 S1-01501275002 S1-01501276002 S1-01501211002 S1-01501294002 S1-01501296002 S1-01501297002

38

• Low vibration & noise • Refrigerant — HCFC-22 • Foot print — 7.5 x 7.5

MODEL NO.

CAPACITY BTUH

V-PH-HZ

RLA

LRA

SUCTION ID HT (S)

AGA5546EXH AGA5546EXT AGC5546EXG AGA5561EXT AGC5561EXG AGA5568EXT AGC5568EXG

45,400 46,800 46,800 61,000 61,000 68,000 68,000

575-3-60 230/200-3-60 460-3-60 230/200-3-60 460-3-60 230/200-3-60 460-3-60

5.3 13.5 7.0 18.0 9.5 20.2 10.6

30.0 93.0 47.0 126.0 62.0 135.0 75.0

7/8 7/8 7/8 7/8 7/8 7/8 7/8

15.1 15.1 15.1 15.6 15.6 16.1 16.1

STOCKED NON STOCKED

DISCH ID

OVALL HT (H)

SHIP WT. (LBS.)

CCH

RUN CAP

MLP

1/2 1/2 1/2 1/2 1/2 1/2 1/2

15.6 15.6 15.6 16.1 16.1 16.6 16.6

96 96 96 101 101 104 104

Y Y Y Y Y Y Y

N/A N/A N/A N/A N/A N/A N/A

$1681.76 1685.88 1893.35 2082.77 2103.29 2189.64 2198.64

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TECUMSEH COMPRESSOR ACCESSORIES

High Torque Start Components Note: Compressor starting characteristics are definite. These high torque starting components are listed for Tecumseh compressors only. Do not attempt to cross reference to other manufacturers.

COMPRESSOR MODEL NO.

B/M NO.

MFD/VAC

AJA5518EXC AJA5517EXD AJC5519EXD AJB5515EXD AKA5510EXD AKA5512EXV AKA8513EXA AKA8513EXD AV5532H AVA5535EXC AVC5535EXN AW5517F AW5517E AW5528E AW5530F AW5519E AW5522E AW5524E AW5524E AW5520E AW5532E AW5532E AWF5517EXN AWG5528EXN AWF5530EXN

AJ200KT AJ210FT AJ222FT AJ600FT AK100ET AK111JB AK144AT AK144ET AV115ET AV122JT AV124ET AW100ET AW100FT AW101FT AW102ET AW103KT AW104FT AW105FT AW105KT AW107FT AW108FT AW108KT AW501ET AW706ET AW508ET

21-25/250 21-25/250 21-25/330 21-25/250 21-25/250 21-25/330 21-25/250 21-25/250 88-108/330 88-108/250 88-108/330 21-25/330 21-25/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 88-108/330 145-175/330

START CAPACITOR SOURCE 1 PART NO. N/A N/A N/A N/A N/A N/A N/A N/A S1-02425191700 S1-02425191700 S1-02425191700 N/A N/A S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425191700 S1-02425071700

MLP — — — — — — — — $18.42 18.42 18.42 — — 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 18.42 17.23

START RELAY CONTACT RATING (AMP)

COLD PICK-UP

DROP OUT

COIL VOLTS

SOURCE 1 PART NO.

162-175 162-175 162-175 162-175 170-180 180-195 170-180 170-180 162-175 162-175 162-175 162-175 162-175 162-175 162-175

40-90 40-90 40-90 40-90 40-90 40-105 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90 40-90

332 332 332 332 336 375 336 336 332 332 332 332 332 332 332

50 50 50 50 35 35 35 35 50 50 50 50 50 50 50

S1-02425392700 S1-02425392700 S1-02425392700 S1-02425392700 S1-02425923700 S1-02425189700 S1-02425923700 S1-02425923700 S1-02425392700 S1-02425392700 S1-02425392700 S1-02425392700 S1-02425392700 S1-02425392700 S1-02425392700

$46.41 46.41 46.41 46.41 58.33 40.94 58.33 58.33 46.41 46.41 46.41 46.41 46.41 46.41 46.41

162-175 162-175 180-193 162-175 162-175 162-175 205-234

40-90 40-90 40-90 40-90 40-90 40-90 40-90

332 332 332 332 332 332 332

50 50 50 50 50 50 35

S1-02425392700 S1-02425392700 S1-02425389700 S1-02425392700 S1-02425392700 S1-02425392700 S1-02425394000

46.41 46.41 46.35 46.41 46.41 46.41 43.08

205-234

40-90

332

35

S1-02425394000

43.08

MLP

NOTE: When substituting compressors always check the capacitor MFD and voltage (when required) and replace if necessary. The capacitor MUST be the proper MFD and voltage for the compressor.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

39


hemrichelectric.com

info@hemrichelectric.com

TECUMSEH COMPRESSOR ACCESSORIES

Crankcase Heaters (CCH) For Tecumseh Application

SOURCE 1 PART NO. S1-02533326000 S1-02532895000 S1-02519840700 S1-02519961701 S1-02533474240 S1-02533474480 S1-02533474575 S1-02519840700 S1-02527413000 S1-02515525702 S1-02531960000

TYPE

FIG.

LENGTH OF ELEMENT

VOLTS

WATTS

USED WITH COMPR.

MLP

INSERTION INSERTION WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND WRAP AROUND

1 1 2 2 2 2 2 2 2 2 3

N/A N/A 29 - 36 24 - 30 29 - 36 29 - 36 29 - 36 29 - 36 22 - 26 27 - 33 22 - 26

100 - 600 100 - 600 120 240 240 480 575 120 240 240 480

30 47 90 45 90 90 90 90 42 54 80

AW AG, AV AV AW AG, AV AG, AV AG, AV AG, AV AJ, AK AG, AV, AW AJ, AK

$ 23.24 126.90 26.41 28.23 42.30 45.84 42.24 26.41 61.77 27.62 86.77

NOTE: For proper application of insertion type CCH, heat conductive compound S1-01301502000 or equivalent must be used. S1-01302250700 is available from SOURCE 1.

Premier Mfg. Compressor Blankets For Noise Suppression Features: •Vinyl w/1/2 inch foam backing •1 Inch wide velcro fasteners •UL recognized materials SOURCE 1 PART NO.

FITS COMPRESSOR MODEL NO.

MLP

AW AG AV

$62.56 81.44 64.83

S1-01004620000 S1-01005669000 S1-01005827000

Scott Mfg. “Acousticap” Compressor Blankets For Noise Suppression Features: •Superior noise reduction (NRC = 85) •Molded closed cell foam shell w/acoustical liner •Snap fasteners for ease of installation (some modification may be required) •UL recognized materials SOURCE 1 PART NO.

FITS COMPRESSOR MODEL NO.

MLP

AG, AV AW AJ, AK

$71.77 64.70 61.07

S1-01005977000 S1-01005978000 S1-01005980000

Compressor Mounting Isolators SOURCE 1 PART NO. S1-02807772000 S1-02809519000 S1-02810581000

40

DUROMETER

A

65 45 40

0.72 0.72 0.75

STOCKED NON STOCKED

DIMENSION C D 0.44 0.44 0.44

1.25 1.25 1.63

E

MLP

0.94 0.94 1.13

$0.79 1.38 1.73

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Identifying Compressor Failures Most compressors fail due to system malfunctions which must be corrected to prevent repeat failures. After a compressor fails, field examination of the failed compressor often will reveal symptoms of system problems. Proper corrections will help eliminate future failures. REFRIGERANT FLOODBACK •Refrigerant Cooled Compressors •Center and rear bearings worn or seized •Dragging rotor, shorted stator •Progressively scored crankshaft •Worn or broken rods •Worn pistons and cylinders •No evidence of overheating Corrections FLOODED STARTS •Worn or scored rods or bearings •Rods broken from seizure •Erratic wear of crankshaft Corrections SLUGGING •Broken reeds, rods, or crankshaft •Loose or broken backer bolts •Blown head gaskets Corrections

HIGH DISCHARGE TEMPERATURE •Discolored valve plate •Burned valve reeds •Worn pistons, rings, and cylinders •Stator spot burn from metal debris Corrections

LOSS OF OIL •All rods and bearings worn or scored. •Crankshaft uniformly scored. •Rods broken from seizure. •Little or no oil in crankcase. Corrections

ELECTRICAL GENERAL OR UNIFORM BURN Corrections

This is a result of liquid refrigerant returning to the compressor during the running cycle. The oil is diluted with refrigerant to the point it cannot properly lubricate the load bearing surfaces. The liquid washes the oil off the pistons and cylinder walls during the suction stroke causing them to wear during the compression stroke. The liquid dilutes the oil in the crankcase and the refrigerant rich oil will be pumped to the rods and the bearings through the crankshaft. As the refrigerant boils off, there will not be enough oil for sufficient lubrication at bearings furthest from the oil pump. The center and rear bearings may seize or may wear enough to allow the rotor to drop and drag on the stator causing a short. 1. Maintain proper evaporator and compressor superheat. 2. Correct abnormal low load conditions. 3. Install accumulators to stop uncontrolled liquid return. This is the result of refrigerant migrating to the crankcase oil during the off cycle. When the compressor starts, the diluted oil cannot properly lubricate the load bearing surfaces causing an erratic wear or seizure pattern. 1. Locate compressor in warm ambient or install pump down. 2. Check crankcase heater operation. This is the result of trying to compress liquid refrigerant and/or oil in the cylinders. Slugging is caused by floodback on air cooled compressors and severe flooded starts on refrigerant cooled compressors. 1. Maintain proper evaporator and compressor superheat. 2. Correct abnormal low load conditions. 3. Install accumulators to stop uncontrolled liquid return. 4. Locate compressor in warm ambient or install pump down. This is the result of temperatures in the compressor head and cylinders becoming so hot that the oil loses its ability to lubricate properly. This causes rings, pistons, and cylinders to wear resulting in blow by, leaking valves, and metal debris in the oil. 1. Correct abnormal low load conditions. 2. Correct high discharge pressure conditions. 3. Insulate suction lines. 4. Provide proper compressor cooling. This is a result of insufficient oil in the crankcase to properly lubricate the load bearing surfaces. When there is not enough refrigerant mass flow in the system to return oil to the compressor as fast as it is pumped out, there will be a uniform wearing or scoring of all load bearing surfaces. 1. Check oil failure control operation if applicable. 2. Check system refrigerant charge. 3. Correct abnormally low load conditions or short cycling. 4. Check for incorrect pipe sizes and/or oil traps. 5. Check for inadequate defrosts. Many motors fail as a result of mechanical failure. Others are true electrical failures. All windings are uniformly overheated or burned. 1. Check for proper voltage. 2. Check for unbalanced voltage. 3. Check for inadequate motor cooling. This is the result of high current through two of the three phases.

SINGLE PHASE BURN Two phases of a three phase motor are overheated or burned. Corrections 1. Replace contactors. 2. Check for proper motor protection. HALF WINDING SINGLE PHASE BURN Half of two phases of a three phase motor overheated or burned due to one contactor opening one of its contacts on a two contactor application. Correction 1. Replace contactors. HALF WINDING BURN Half of all phases of a two contactor three phase motor are overheated or burned. Corrections 1. Replace contactors. 2. Check for feedback circuit holding one contactor closed. PRIMARY SINGLE PHASE BURN Only one phase of a three phase motor is overheated or burned as the result of opening one phase on the primary side of a delta to wye transformer. Correction 1. Check primary side of delta to wye mainpower transformer. START WINDING BURN Only the start winding of a single phase motor is uniformly overheated or burned. Corrections 1. Check for proper wiring of compressor. 2. Check starting capacitor and/or starting relay. 3. Check compressor overloading. SPOT BURN A localized burn within a winding, between windings, or from windings to ground. Corrections 1. If not the result of mechanical problems, check for spikes or surges of high current flow. SHORTED TERMINALS A breakdown of the insulation between terminals and compressor body. Correction 1. Check for over torquing of terminals.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

41


hemrichelectric.com

info@hemrichelectric.com

TECUMSEH COMPRESSOR ACCESSORIES

Acousticap® Compressor Blankets Features: • Superior noise reduction • UL recognized • Lightweight • Easy installation • Weatherability • Cost-effective ACOUSTICAL PERFORMANCE (SOUND ABSORPTION COEFFICIENTS) FREQUENCY (HZ) ABSORPTION AT 1/3 OCTAVE FREQUENCY ACOUSTICAP®

125 .19

250 .49

500 .88

1000 1.02

2000 1.02

4000 1.03

NRC * .85

* Noise Reduction Coefficient Testing was in accordance with ASTM C-423 and performed by an outside laboratory accredited by the Department of Commerce. ACOUSTICAL PERFORMANCE (SOUND TRANSMISSION LOSS) SOURCE RECEIVE DB DB TL DB

FREQUENCY HERTZ 125 250 500 1000 2000 4000

91.7 91.4 93.3 97.6 97.3 97.4

78.1 79.6 79.6 79.3 69.8 61.0

STC CONTOUR

2.2 2.7 5.8 10.8 17.6 24.4

-5 4 11 14 15 15

Sound Transmission Class (STC) = 11 Testing was in accordance with ASTM E-90 and performed by an outside laboratory accredited by the Department of Commerce. SOURCE 1 PART NO.

SCOTT MFG. MODEL NO.

DIAMETER

FOR USE WITH COMPRESSOR

HEIGHT

S1-01005977000

SC9301A

9-1/2 - 11

15 - 17

S1-01005978000

SC9302A

8 - 9-1/2

13-1/2 - 15-1/2

S1-01005979000

SC9520A

7 - 8-1/2

15 - 17

S1-01005980000

SC9521A

7 - 8-1/2

12 - 15

MLP

H23A, H24A, H25A, H26A, H27A, H87A ALL MODELS CRN AND LARGER ALL CR _ _ K6 H20 AND H21C - ALL MODELS, H20 AND 21R - 483 AND SMALLER CRK - CRM, ZR40 AND SMALLER H23B, H24B, H25B, H26B - ALL MODELS CRH AND SMALLER, RE ALL AW AND AV

$71.77 64.70 66.35 61.07

Compressor Grommets SOURCE 1 PART NO.

COMPRESSOR

MLP

1 TO 5 TON

$10.88

S1-MA-9001

MLP per each / Sold 4 per package

Crankcase Heaters

Girth Dimensions

42

SOURCE 1 PART NO.

DESCRIPTION

MIN.

MAX.

SHAPE

MLP

S1-MA-CH101-3 S1-MA-CH102 S1-MA-CH102-2

480V, 54 WATT 240V, 60 WATT 120V, 60 WATT

27-7/16 25-3/4 25-3/4

34-1/4 32-9/16 32-9/16

OVAL OVAL OVAL

$40.74 40.74 40.74

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

REFRIGERANT HANDLING EQUIPMENT

INDUSTRIES INC. REFRIGERANT CHARGING EQUIPMENT

R22 & R410a Charging Manifolds Features: • O-Ring Sealing System • Refrigerant Color Coded Dials • Surge Dampened Gauges For Reduced Pointer Movement • Pull-Out Proof Hanging Hook

• • • •

SOURCE 1 PART NO.

Hose Holder Mounts To Front Or Back Of Bar Knuckle Clearance Angled Bar All Intake Fittings Replaceable Color Coded Durable Nylon Handwheels

DESCRIPTION

MLP

STANDARD MANIFOLDS NEW S1-M2-8-410A STANDARD MANIFOLD W/O HOSES, R410a NEW S1-M2-5-410A STANDARD MANIFOLD W/60” CCL HOSE SET, R410a NEW S1-M2-22225 STANDARD MANIFOLD W/O HOSES, 80MM GAUGES S1-M2-36 WITH 36” STANDARD HOSE SET S1-M2-6 3’ (36”) RED & BLUE AND 5’ (60”) YELLOW S1-M2-5 WITH 60” STANDARD HOSE SET FORGED BAR R410a MANIFOLDS NEW S1-24225 2-VALVE ALUMINUM MANIFOLD W/O HOSES, 80MM ILUMINATING GAUGES NEW S1-25225 4-VALVE ALUMINUM MANIFOLD W/60” CCLE HOSES, 80MM ILLUMINATING GAUGES S1-23500 NO HOSE SET S1-23506 ENVIRO-SAFE HOSE SETS 5’ (60”) S1-23513 ENVIRO-SAFE HOSE SETS WITH BALL VALVE SHUT-OFF 5’ (60”)

$120.36 242.46 149.93 167.11 154.01 181.79 $228.21 317.14 148.19 231.75 339.52

R22 & R410a Charging Manifold Gauges SOURCE 1 PART NO.

Specifications: Compound Gauges: 30” Vacuum to 120 PSI, Retard to 350 PSI (R410a gauges 250/500 PSI) Pressure Gauges: 0 to 500 PSI (R410a gauges 0 to 800 PSI)

COMPOUND GAUGES (°F) S1-M2-250 S1-M2-410 NEW S1-M2-460 NEW S1-M2-465 PRESSURE GAUGES S1-M2-500 S1-M2-415 NEW S1-M2-820 NEW S1-M2-825

DESCRIPTION

MLP

BLUE PLASTIC CASE R410A COMPOUND GAUGE 2-1/2 BLUE COMPOUND GAUGE 2-1/2 RED PRESSURE GAUGE

$25.32 30.88 35.36 35.36

RED PLASTIC CASE R410A PRESSURE GAUGE 80MM ILLUMINATING BLUE COMPOUND GAUGE 80MM ILLUMINATING RED PRESSURE GAUGE

$24.89 30.28 60.64 60.64

CL Series Charging Hoses SOURCE 1 PART NO. S1-CCL-36 S1-CCL-48 S1-CCL-60 S1-CCL-72

DESCRIPTION

COLOR

CL SERIES CHARGING HOSES CL SERIES CHARGING HOSES CL SERIES CHARGING HOSES CL SERIES CHARGING HOSES

COLOR-CODED SETS

LENGTH (IN INCHES)

MLP

36 48 60 72

56.28 64.50 70.75 81.22

Replacement Parts for CL Series Charging Hoses SOURCE 1 PART NO.

Features: • Blowout resistant depressor and barrel gasket • Depressor set to ARI Standard for access valve core • Slotted Coupler prevents back spray

S1-P90513 S1-P509

DESCRIPTION

MLP

DEPRESSOR 1/4” GASKET

$4.59 4.20

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

43


hemrichelectric.com

info@hemrichelectric.com

INDUSTRIES INC. REFRIGERANT CHARGING EQUIPMENT

Enviro-Safe CLS Series Charging Hoses with Secure-Seal Fitting SOURCE 1 PART NO. S1-CLS-36B S1-CLS-48B S1-CLS-60B S1-CLS-72B S1-CLS-36R S1-CLS-48R S1-CLS-60R S1-CLS-72R S1-CLS-36Y S1-CLS-48Y S1-CLS-60Y S1-CLS-72Y S1-CCLS-36 S1-CCLS-48 S1-CCLS-60 S1-CCLS-72

DESCRIPTION

COLOR

CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS CHARGING HOSE CLS SERIES CHARGING HOSES CLS SERIES CHARGING HOSES CLS SERIES CHARGING HOSES CLS SERIES CHARGING HOSES

LENGTH (IN INCHES)

MLP

36 48 60 72 36 48 60 72 36 48 60 72 36 48 60 72

$ 34.83 39.04 43.25 47.50 34.83 39.04 43.25 47.50 34.83 39.04 43.25 47.50 101.90 125.12 121.63 158.23

BLUE

RED

YELLOW

COLOR-CODED SET

Replacement Parts for CLS Series Charging Hoses Features: • Opens to Full Flow • Automatically traps refrigerant discharge in hose NOTE: Not for use with R-410a Refrigerant

SOURCE 1 PART NO. S1-P90022

DESCRIPTION

MLP

REPLACEMENT O-RING

$5.51

Enviro-Safe CLE Series Charging Hoses with Gasket Seal Fitting SOURCE 1 PART NO. S1-CLE-36B S1-CLE-48B S1-CLE-60B S1-CLE-72B S1-CLE-36R S1-CLE-48R S1-CLE-60R S1-CLE-72R S1-CLE-36Y S1-CLE-48Y S1-CLE-60Y S1-CLE-72Y S1-CCLE-36 S1-CCLE-48 S1-CCLE-60 S1-CCLE-72

DESCRIPTION

COLOR

CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE CHARGING HOSE CLE SERIES CHARGING HOSES CLE SERIES CHARGING HOSES CLE SERIES CHARGING HOSES CLE SERIES CHARGING HOSES

BLUE

RED

YELLOW

COLOR-CODED SET

LENGTH (IN INCHES)

MLP

36 48 60 72 36 48 60 72 36 48 60 72 36 48 60 72

$22.45 26.21 29.96 33.80 22.45 26.21 30.24 33.80 22.45 26.21 29.96 33.80 65.70 65.07 85.16 98.76

Replacement Parts for CLE Series Charging Hoses SOURCE 1 PART NO.

Features: • Blowout resistant depressor and barrel gasket • Depressor set to ARI Standard for access valve core

44

S1-P90513 S1-P509

STOCKED NON STOCKED

DESCRIPTION

MLP

DEPRESSOR 1/4” GASKET

$4.59 4.20

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

INDUSTRIES INC. REFRIGERANT CHARGING EQUIPMENT

Enviro-Safe CLV Series Charging Hoses with Secure-Seal Fitting SOURCE 1 PART NO. S1-CLV-36B S1-CLV-48B S1-CLV-60B S1-CLV-72B S1-CLV-36R S1-CLV-48R S1-CLV-60R S1-CLV-72R S1-CLV-36Y S1-CLV-48Y S1-CLV-60Y S1-CLV-72Y

Features: • Blowout Resistant Depressor and Barrel Gasket • Quarter turn On/Off • UL approved Shut-Off ball valve • Depressor set to ARI Standard for access valve core Replacement Parts for CLV Series Charging Hoses SOURCE 1 PART NO. S1-P90022

DESCRIPTION

MLP

REPLACEMENT O-RING

$5.51

S1-CCLV-36 S1-CCLV-48 S1-CCLV-60 S1-CCLV-72

DESCRIPTION

COLOR

CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV CHARGING HOSE CLV SERIES CHARGING HOSES CLV SERIES CHARGING HOSES CLV SERIES CHARGING HOSES CLV SERIES CHARGING HOSES

LENGTH (IN INCHES)

MLP

36* 48* 60* 72* 36* 48* 60* 72* 36* 48* 60* 72*

$ 52.62 53.61 57.50 62.11 52.62 55.75 57.50 62.11 52.62 54.41 58.89 62.11

36*

168.10

48*

170.92

60*

165.79

72*

189.68

BLUE

RED

YELLOW

COLORCODED SET

* Hoses come with 6” Whip End

Platinum Series Vacuum Pumps Features: • 2 stage Direct Drive • 25 micron field tested (Thermistor Gauge reading) • Check Valve prevents oil backflow during power failure • Low profile rocker switch • Completely field repairable • One micron on a U-tube manometer; 25,400 microns = “1” Shipping Container Dimensions = 14-7/8”H x 9-5/16”W x 16-1/2”L

DESCRIPTION

FREE AIR DISPLACEMENT (L/MIN.)

INTAKE PORTS (MALE FLARE)

OIL CAPACITY

SHIP WEIGHT

MLP

1/2 HP, 115 V, 60 HZ, 1725 RPM 1/2 HP, 115 V, 60 HZ, 1725 RPM 1/2 HP, 115 V, 60 HZ, 1725 RPM

3 CFM (85) 5 CFM (142) 7 CFM (200)

1/4” X 3/8” 3/8” X 1/4” X 3/8” 3/8” X 1/4” X 3/8”

27 OZ. (785 CC) 23 OZ. (660 CC) 23 OZ. (660 CC)

30 LBS. 32 LBS. 30 LBS.

$837.24 930.56 987.43

SOURCE 1 PART NO. S1-DV-85N S1-DV-142N S1-DV-200N

Eliminator Vacuum Pump Features: • 3CFM with 1/2 HP motor • 25 micron field tested (thermistor gauge reading) • Wide stance feet for stability • 2-stage direct drive design • O-ring seal drain valve • Check valve prevents oil backflow during power failure • Low-profile rocker switch helps prevent damage and accidental shut off • 16-ounce oil capacity for good contaminant absorption and easy oil changes Completely field repairable SOURCE 1 PART NO. S1-DV-4E S1-DV-6E

DESCRIPTION

FREE AIR DISPLACEMENT

ELIMINATOR VACUUM PUMP ELIMINATOR VACUUM PUMP

4 CFM 6 CFM

SPECIFICATIONS

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

MLP

$627.86 1/2 HP, 115 V, 60 HZ, 1725 RPM 708.81

45


hemrichelectric.com

info@hemrichelectric.com

INDUSTRIES INC. REFRIGERANT CHARGING EQUIPMENT

Digital Vacuum Gauges

JB’s Digital Vacuum Gauge reads vacuum in 7 international units: Microns, PSIA, InHg, mBars, Pascals, Torr, and mTorr. The DV- N has a micron range of 0 to 9,000 Microns. It is a good idea to attach the micron gauge to the vacuum pump before evacuation to make sure the pump pulls down to at least 50 microns. If it

doesn't, your pump is contaminated and the oil should be changed. A compound gauge only indicates that a vacuum is being produced, but does not tell you if moisture or acids are still in the system. The DV- N, however, is the only tool to accurately read the low pressure produced when evacuation/ dehydration is complete. Note: The DV-22N is not recommended for connection to vacuum pump when blanking off isolation valve. Features: • Simple two button operation for convenience • Sealed touch buttons protect unit against dust and spills • Low battery indicator lets you know when to replace the 9 volt battery (not included)

SOURCE 1 PART NO. NEW NEW

S1-DV22N S1-DV24N

• Powers off after 10 minutes to save battery life • Retractable hanging hook so the DV- N can hang or lie flat • NIST Traceable • Leak-proof with O-ring coupler to ensure proper register of vacuum in system • Digital display with solid state circuitry so there is no adjustment necessary for fluctuating temperatures. • Saves last vacuum readout after shut down for added convenience Specifications: Effective Range: 20–9,000 microns Ambient Temperature: +32°F to +120°F (0°C to 48.9°C)

DESCRIPTION

MLP

HAND HELD DIGITAL VACUUM GAUGE DV-22N WITH PROTECTIVE CARRYING CASE

$506.71 573.18

Vacuum Pump Oil SOURCE 1 PART NO. S1-DVO-1 S1-DVO-12 S1-DVO-24

DESCRIPTION

CARTON QTY.

SIZE

WEIGHT

MLP*

PINT BOTTLE QUART BOTTLE GALLON BOTTLE

24 12 6

8-1/2” X 14-1/2”L X 10”W 9-3/4”H X 13”L X 9-3/4”W 13”H X 16”L X 13”W

25 LBS. 25 LBS. 50 LBS.

$ 9.17 12.86 38.34

* Items are priced per each but must be ordered in carton quantities.

WinLine HVAC Pocket Calculator • Converts pressure to temperature and temperature to pressure for refrigerant gases; 11, 12, 22, 500, 502 and 717 • Clocks BTU/HR input of natural gas through a gas meter • Determines % of relative humidity by entering dry and wet bulb temperature • Converts °F to °C and °C to °F • Full four function calculator • Uses two CR2016 lithium batteries

46

STOCKED NON STOCKED

SOURCE 1 PART NO. S1-52635014000

MFG. NO. DESCRIPTION 100

HVAC POCKET CALCULATOR

MLP $144.64

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

LINE PIERCING VALVES AND TOOLS

MAC—The Ultimate in Line Piercing Valves into head of needle. Wing cap is turned down easily by hand until line is pierced. Wing cap is removed and system may be serviced with any charging hose with built-in depressor. When hose is removed, spring loaded needle backseats forming a leak proof seal. Needle depressor is discarded and wing cap forms extra precautionary seal.

Install valve. Connect charging hose. Service. That’s all there is to it! MAC features uniport: 1 connection for piercing and servicing. Sealed with refrigerant resistant “O” rings. Needle automatically back seats after servicing, leaving line free of restriction. Connect to tubing with 2 socket-head screws. (Hex wrench is included with each valve.) Needle depressor is inserted SOURCE 1 PART NO.

DESCRIPTION

STD. PACK

MLP*

MAC LINE PIERCING VALVE – 1/4”, 5/16”, 3/8” O.D. TUBE SIZE MAC LINE PIERCING VALVE – 1/2”, 5/8” O.D. TUBE SIZE MAC LINE PIERCING VALVE – 3/16”, 1/4” O.D. TUBE SIZE

36 36 36

$6.25 6.75 7.68

l

NEW NEW NEW

S1-QTM-1 S1-QTM-2 S1-QTM-3

*Sold by pack / MLP per each

Quick-Tap Features a valve core in the 1/4” male port. Simply pierce the line and back seat the needle. Flow starts when depressor type charging hose is connected. Flow shuts off automatically when hose is removed. If valve core is not desired, it may be SOURCE 1 PART NO.

removed. Connect hose, pierce line and back seat needle. This method offers full unrestricted flow. Valve core can be removed or changed at any time without loss of refrigerant if needle is front seated. DESCRIPTION

MLP

QUICK-TAP – 1/4”, 5/16”, 3/8” O.D. TUBE SIZE QUICK-TAP – 1/2”, 5/8” O.D. TUBE SIZE

$8.36 9.04

l

NEW NEW

S1-QT-1 S1-QT-2

Quick-Tap-2 Identical to Quick-Tap except that a nylon handle replaces the hex wrench. Phillips-head screws are used. SOURCE 1 PART NO.

DESCRIPTION

MLP

QUICK-TAP-2 – 1/4”, 5/16”, 3/8” O.D. TUBE SIZE QUICK-TAP-2 – 1/2”, 5/8” O.D. TUBE SIZE

$13.36 14.25

l

NEW NEW

S1-QTH-1 S1-QTH-2

Line Tap & Swivel Valves The quick, safe and easy option to charge, discharge and test a line. Simply clamp on the DLT valve, attach the DCV-1G control valve, and pierce the line. The control valve features a port for connecting charging lines or gauges. The valve can swivel to any position and also be removed and re-used. These line tap valves are also difficult to tamper with as the line can only be accessed by using the special DCVSOURCE 1 PART NO.

1G valve. They feature a specially formulated gasket which can withstand heat up to 302ºF. Available in four sizes from 3/16” OD tube size to 3/8”. The DCV1G is designed for use with all four sizes. DLT series line taps are also compatible with existing A-1 Components CV-1G valves and likewise DCV-1G valves are compatible with A-1 Components LT-series line taps. DESCRIPTION

MLP

LINE TAP VALVE – 3/16” OD TUBE LINE TAP VALVE – 1/4” OD TUBE LINE TAP VALVE – 5/16” OD TUBE LINE TAP VALVE – 3/8” OD TUBE VALVE FOR DLT LINE TAPS

$ 6.25 7.14 6.25 7.14 10.39

l

NEW NEW NEW NEW NEW

S1-DLT-3G S1-DLT-4G S1-DLT-5G S1-DLT-6G S1-DCV-1G

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

47


hemrichelectric.com

info@hemrichelectric.com

LINE PIERCING VALVES AND TOOLS

Copper Saddle Valve For copper-to-copper brazing. Penetrates line in one easy operation with no holes to drill. Steel pin with valve core pierces line and is locked into valve body by tightening cap. Teflon ring assures positive seal. Available in sizes from 1/4” to 1-1/8”. SOURCE 1 PART NO.

DESCRIPTION

STD. PACK

MLP*

COPPER SADDLE VALVE – 1/4” O.D. TUBE SIZE COPPER SADDLE VALVE – 5/16” O.D. TUBE SIZE COPPER SADDLE VALVE – 3/8” O.D. TUBE SIZE COPPER SADDLE VALVE – 1/2” O.D. TUBE SIZE COPPER SADDLE VALVE – 5/8” O.D. TUBE SIZE COPPER SADDLE VALVE – 3/4” O.D. TUBE SIZE COPPER SADDLE VALVE – 7/8” O.D. TUBE SIZE COPPER SADDLE VALVE – 1-1/8” O.D. TUBE SIZE ADDITIONAL TEFLON RINGS

6 6 6 4 3 2 2 2 25

$5.75 5.75 5.75 6.21 6.82 7.68 7.68 7.68 0.50

l

NEW NEW NEW NEW NEW NEW NEW NEW NEW

S1-VLC-4 S1-VLC-5 S1-VLC-6 S1-VLC-8 S1-VLC-10 S1-VLC-12 S1-VLC-14 S1-VLC-18 S1-VLC-25

*Sold by pack / MLP per each

Core Storer All steel valve core remover and storage container. Completely knurled for easier grip, eliminating slippage when using with oily or greasy hands. Core Storer features a compartment for storing extra valve cores. Four replacement cores are included with each tool. SOURCE 1 PART NO.

DESCRIPTION

MLP

CORE REMOVER AND STORER

$12.96

l

NEW

S1-VCR-1

Core Removal Tool Designed to remove and replace valve cores without losing the refrigerant charge. Connects to any 1/4” male flare fitting. Saves time, saves refrigerant. SOURCE 1 PART NO.

DESCRIPTION

MLP

CORE REMOVAL TOOL REPLACEMENT ROD ASSEMBLY REPLACEMENT O-RING KIT REPLACEMENT SHUT-OFF STEM

$73.21 18.39 2.32 19.32

l

NEW NEW NEW NEW

S1-VCRT-1 S1-VCRT-1R S1-VCRT-1RK S1-VCRT-1S

Insta-Tap Refrigerant Recovery Tool The fastest, easiest way to evacuate refrigerant before disposal of a unit. Snaps onto refrigerant line for full and immediate flow. Punctures super large hole for maximum full flow discharge to recovery unit. One tool fits all sizes from 3/16” to 7/8” O.D. hard tubing. Replaceable needle. SOURCE 1 PART NO.

DESCRIPTION

STD. PACK

MLP*

QUICK-TAP-2 – 1/4”, 5/16”, 3/8” O.D. TUBE SIZE REPLACEABLE HARDENED STEEL NEEDLE AND GASKET REPLACEMENT GASKET ONLY

1 1 3

$78.71 8.57 0.79

l

NEW NEW NEW

S1-QT-100 S1-QT-100N S1-QT-100G

*Sold by pack / MLP per each

48

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

REFRIGERANT RECOVERY PRODUCTS

Refrigerant Recovery Cylinders DOT Classified for recovery, recycling, service and reclaim. Liquid and vapor valves (“Y” valve or separate valve configurations) are installed in all cylinders. Painted yellow/gray per ARI guidelines. Float switches have 3-pin Brad Harrison connectors. Caution: Never overfill cylinders. Maximum refrigerant capacity is limited to 80% of the water capacity of the cylinder in lbs. (see table below). DOT requires cylinders to be retested every five years. Some recovery equipment uses weight scales to cut off refrigerant fill at 80% of capacity. Be sure cylinder tare weight is correct for this type of equipment. DOT Classification Example: 4BA400: 400 psi working pressure; 800 psi test pressure (double the working pressure); 1,600 psi minimum burst pressure (double the test pressure). Pressure relief/safety valve is set to release at between 75-100% of the test pressure. For SOURCE 1 PART NO. NEW NEW NEW NEW NEW NEW

S1-02033 S1-02035 S1-02053 S1-02055 S1-02100 S1-02255

example, in the 4BA400 tanks which have a 800 psi test pressure, the relief valve opens at between 600 psi and 800 psi.

DESCRIPTION

DOT CLASS

3/4” NPT PLUG

FLOAT SWITCH

WATER CAP.

TARE WT.

MLP

30 LB. 30 LB. 50 LB. 50 LB. 100 LB. 250 LB.

4BA400 4BA400 4BA400 4BA400 4BW400 4BW260

YES NO YES NO NO YES

NO YES NO YES NO NO

26.2 LBS. 26.2 LBS. 47.7 LBS. 47.7 LBS. 123 LBS. 239 LBS.

17 LBS. 17 LBS. 28 LBS. 28 LBS. 48 LBS. 85 LBS.

$267.18 437.54 289.54 464.79 665.46 946.93

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

49


hemrichelectric.com

info@hemrichelectric.com

REFRIGERANT CHARGING PRODUCTS

Oil Transfer System by Gauge-Pro A quick and easy way to change refrigerant oil with no spillage or mess. Unique hand pump creates a powerful vacuum for the transfer of oil to or from the compressor crank case at a faster rate. Oil transfers back and forth between the compressor and waste oil tank by creating a vacuum. Oil never touches the pump, thus preventing cross contamination. Pump, durable waste oil container and all hoses are included. SOURCE 1 PART NO.

DESCRIPTION

MLP

OIL TRANSFER SYSTEM – 1-1/4 GALLON OIL TRANSFER SYSTEM – 2-1/2 GALLON

$211.54 239.11

l

NEW NEW

S1-GOTS-1 S1-GOTS-2

Insta-Charge Faster, safer and more economical method for charging LIQUID refrigerant through the low pressure side of an air conditioning or refrigeration system, without damaging the compressor. InstaCharge’s unique internal restrictor reduces liquid flow to a level below the capacity of the compressor. SOURCE 1 PART NO.

Converts liquid refrigerant to a saturated vapor for fast entry. Insta-Charge connects directly to the refrigerant can or cylinder valve. Adds liquid tracing dye faster. Eliminates heating of refrigerant cylinder. Made of light weight aluminum. Sold at a fraction of the cost of other fast charging devices. DESCRIPTION

MLP

INSTA-CHARGE

$14.54

l

NEW

S1-RC-1

Cushion Clamps An industry standard universal clamp that mounts to standard strut. Steel with electro-dichromate finish to resist corrosion. The lock nut has a nylon insert for a positive lock. The polymeric grommet withstands temperatures from -25°C to 125°C and resists the effects of most oils, chemicals, and industrial cleaning compounds. SOURCE 1 PART NO.

DESCRIPTION

STD. PACK

MLP*

CUSHION CLAMP – 1/4” CUSHION CLAMP – 3/8” CUSHION CLAMP – 1/2” CUSHION CLAMP – 5/8” CUSHION CLAMP – 3/4” CUSHION CLAMP – 7/8” CUSHION CLAMP – 1-1/8” CUSHION CLAMP – 1-3/8” CUSHION CLAMP – 1-5/8” CUSHION CLAMP – 2-1/8” CUSHION CLAMP – 2-5/8” CUSHION CLAMP – 3-1/8” CUSHION CLAMP – 3-5/8” CUSHION CLAMP – 4-1/8”

25/BOX 25/BOX 25/BOX 25/BOX 25/BOX 25/BOX 10/BOX 10/BOX 10/BOX 10/BOX 10/BOX 10/BOX 10/BOX 10/BOX

$ 5.39 5.43 5.39 5.50 6.39 6.96 8.07 9.68 12.75 24.68 26.68 34.79 51.61 68.36

l

NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW

S1-538-1/4 S1-538-3/8 S1-538-1/2 S1-538-5/8 S1-538-3/4 S1-538-7/8 S1-538-1-1/8 S1-538-1-3/8 S1-538-1-5/8 S1-538-2-1/8 S1-538-2-5/8 S1-538-3-1/8 S1-538-3-5/8 S1-538-4-1/8

*Sold by box / MLP per each

50

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

REFRIGERANT LABELS

Identification Labels These self-adhesive vinyl labels use a high-tack acrylic adhesive and UV cured screen printing. Color coded to conform to refrigerant labeling convention. each label indicates the type of refrigerant (eg. R-11), the chemical name (eg. Trichloromonofluromethane) and the UN No. (eg. UN 1078). Avoid costly mistakes by properly identifying the type of refrigerant contained in recovery cylinders and air conditioning and refrigeration equipment. SOURCE 1 PART NO. NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW

S1-04000 S1-04010 S1-04011 S1-04012 S1-04013 S1-04022 S1-04023 S1-04056 S1-04113 S1-04114 S1-04123 S1-04134 S1-04401 S1-04402 S1-04404 S1-04406 S1-04407 S1-04410 S1-04414 S1-04451 S1-04452 S1-04500 S1-04502 S1-04503 S1-04507 S1-04509

NEW

S1-04700

NEW NEW NEW NEW

S1-04800 S1-04803 S1-04850 S1-04852

NEW NEW NEW

S1-04870 S1-04871 S1-04872

DESCRIPTION REFRIGERANT ID LABELS (3” X 4”) ASSORTED REFRIGERANT ID LABELS (R-12, R-22, R-502) R-408A (FX10) REFRIGERANT ID LABELS R-11 REFRIGERANT ID LABELS R-12 REFRIGERANT ID LABELS R-13 REFRIGERANT ID LABELS R-22 REFRIGERANT ID LABELS R-23 REFRIGERANT ID LABELS R-409A (FX56) REFRIGERANT ID LABELS R-113 REFRIGERANT ID LABELS R-114 REFRIGERANT ID LABELS R-123 REFRIGERANT ID LABELS R-134A REFRIGERANT ID LABELS R-401A (MP39) REFRIGERANT ID LABELS R-402A (HP80) REFRIGERANT ID LABELS R-404A (HP62/FX70) REFRIGERANT ID LABELS R-406A (GHG) REFRIGERANT ID LABELS R-407C (SUVA 9000/KLEA 66) REFRIGERANT ID LABELS R-410A (AZ20) REFRIGERANT ID LABELS R-414B REFRIGERANT ID LABELS R-401B (MP66) REFRIGERANT ID LABELS R-402B (HP81) REFRIGERANT ID LABELS R-500 REFRIGERANT ID LABELS R-502 REFRIGERANT ID LABELS R-503 REFRIGERANT ID LABELS R-507 (AZ50) REFRIGERANT ID LABELS R-416A REFRIGERANT ID LABELS NON-FLAMMABLE GAS LABELS (4” X 4”) NON FLAMMABLE GAS LABELS SYSTEM REFRIGERANT/OIL LABELS (3” X 4”) EPA WARNING LABELS LABELS EPA WARNING LABELS LABELS, R22H REFRIGERANT REMOVED LABELS SYSTEM REFRIGERANT/OIL LABELS SYSTEM LUBRICANT IDENTIFICATION LABELS (2” X 3”) POLYOL ESTER OIL LABELS MINERAL OIL LABELS ALKYLBENZINE OIL LABELS

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

STD. PACK

MLP

30 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

$21.89 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21 9.21

10

$ 9.21

10 10 10 10

$ 6.46 6.46 9.21 9.21

10 10 10

$ 9.21 9.21 9.21

51


hemrichelectric.com

info@hemrichelectric.com

Air Conditioning & Heating Controls

Your Source1 Connection


hemrichelectric.com

THERMOSTATS

TSTATFORMARKERAIR CONDITIONING & HEATING UNITS & CONTROLS

HVAC SERVICE PARTS

info@hemrichelectric.com

53 Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL & COMMERCIAL ACCESSORY THERMOSTATS

Source 1 LX-Series Thermostats Available March 2009

• •

Source 1 LX-Series thermostats are suitable for residential or commercial gas/electric, heat pump, multistage, and hydronic systems. They offer an extraordinarily rich set of features. A variety of matching accessories offer extended functionality to the dealer and the home or building owner. Features: • Large (4.7 sq in) digital display with soft white adjustable intensity backlight displays SOURCE 1 PART NO.

STAGES HEAT

• • • • • • • • • •

current indoor and outdoor (with optional remote sensor) temperature, setpoints, day of week, and time Adjustable scrolling10-character 16-element marquee text guides through setup and programming steps in plain language and allows customizable service alerts and error messages Bicolor LED mode indicator and backlit, color-coded soft-touch keys Programmable models meet Energy Star and California Title 24 specifications Up to 4 stages heating and 2 stages cooling Up to 7-day installer selectable programming Auto changeover (switchable to manual) Built-in compressor protection (defeatable for zoning applications) Adjustable timers and deadbands Auxiliary heat indicator Auxiliary heat lockout Fahrenheit/Celsius display Service filter reminder UV lamp replacement reminder

COOL

PROGRAMMING OPTIONS

2

1

1-DAY, NONE

3 (4 FOR HEATPUMP)

2

7-DAY, 5+2 DAY, 1-DAY, NONE

• • • •

Remote temperature sensor ready Programmer compatible Wireless accessories Humidification and dehumidification (some models) • Dual fuel capable (some models) Specifications: Power Method: Hardwired Electrical Ratings: 24 VAC ±15% Frequency: 60Hz; 50Hz Terminal Load: Y1, Y2, G 1.5 A per terminal; all others 0.5 A per terminal Setpoint Temperature Range (heating): 35°– 99°F (1.5°–37°C) Setpoint Temperature Range (cooling): 35°– 99°F (1.5°–37°C) Deadband Differential: 1°–6°F (0.5°–3.0°C) Operating Ambient: 35°–105°F (1.5°–41°C) Operating Humidity: 5–90% RH, non-condensing Dimensions: 4-3/8” H x 5-5/16” W x 1” D Mounting: Horizontal

CONTROL

TERMINALS

MLP

RESIDENTIAL MODELS NEW

S1-THSU21P1S

NEW

S1-THSU32P7S

HUMIDIFICATION, DEHUMIDIFICATION, REHEAT, AND DUAL FUEL

NEW S1-THSU32HP7S

R, C, G, W1/O/B, W2, Y1, OUTDOOR SENSOR, $123.21 DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, 185.71 REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, HUM, DEHUM, AUX, 232.14 OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

COMMERCIAL MODELS NEW

S1-TBSU22HNS

NEW

S1-TBSU32P7S

2

HUMIDIFICATION, AND DEHUMIDIFICATION

2 3 (4 FOR HEATPUMP)

7-DAY, 5+2 DAY, 1-DAY, NONE HUMIDIFICATION, DEHUMIDIFICATION, AND REHEAT

NEW S1-TBSU32HP7S

54

NON-PROGRAMMABLE

STOCKED NON STOCKED

R, C, G, W1/O/B, W2, Y1, Y2, HUM, DEHUM, OUTDOOR SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, AUX, HUM, DEHUM, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

$189.29

196.43

239.29

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL & COMMERCIAL ACCESSORY THERMOSTATS

LX-Series Thermostat Accessories

S1-LXPROG

S1-LXCC S1-LXRFM

S1-ADDWIRE

S1-LXPLATE S1-LXLOCK

S1-LXRFTS SOURCE 1 PART NO.

NEW

S1-LXPROG

NEW

S1-LXRFM

NEW

S1-LXCC

NEW

S1-LXRFTS

NEW

S1-LXLOCK

NEW

S1-LXPLATE

NEW

S1-ADDWIRE

DESCRIPTION

MLP

PLUG-IN USB PORT PROGRAMMER FOR LX-SERIES THERMOSTATS - PROGRAM ON YOUR COMPUTER WITH INTUITIVE SOFTWARE - WORKS WITH PC OR MAC - CUSTOMIZE MESSAGES TO APPEAR ON THERMOSTAT DISPLAY - QUICK AND EASY COPYING FROM ONE THERMOSTAT TO THE NEXT - BATTERY BACKUP MAINTAINS CURRENT TIME AND DAY OF THE WEEK - STORES DATA FROM SEVERAL MODELS SIMULTANEOUSLY 900 MHZ WIRELESS TRANSCEIVER MODULE FOR LX-SERIES THERMOSTATS - TWO WAY WIRELESS COMMUNICATION - LINKS MULTIPLE SENSORS AND ACCESSORIES TO THE THERMOSTAT - FREQUENCY HOPPER TO AVOID INTERFERENCE - EASY TWO MINUTE INSTALLATION COMFORT CALL ACCESSORY FOR LX-SERIES THERMOSTATS (REQUIRES WIRELESS TRANSCEIVER MODULE) - ALLOWS SIMPLE REMOTE CONTROL OF THE THERMOSTAT FROM ANY PHONE - VOICE RECOGNITION OR TOUCH-TONE ENTRY - ANNOUNCES INDOOR AND OUTDOOR TEMPERATURES/INDOOR HUMIDITY - ANNOUNCES SYSTEM STATUS - CONTROLS UP TO FOUR THERMOSTATS - CAN CONTROL ONE AUXILIARY OUTPUT - EASY TO INSTALL INDOOR/OUTDOOR WIRELESS TEMPERATURE SENSOR FOR LX-SERIES THERMOSTATS (REQUIRES WIRELESS TRANSCEIVER MODULE) - AUTOMATIC REMOTE SENSOR AVERAGING WHEN USING MORE THAN ONE (INDOOR) SENSOR - CAN LINK WITH UP TO FOUR THERMOSTATS - LONG BATTERY LIFE LOCKING RING FOR LX-SERIES THERMOSTATS - DESIGNED FOR EASY TOOL-LESS SLIP-ON INSTALLATION AND SLIP-OFF REMOVAL - THERMOSTAT REMOVAL OR WIRING DISCONNECTION NOT REQUIRED FOR INSTALLATION - CAN BE COMBINED WITH KEYPAD LOCKOUT OR SETPOINT LIMITS - LOCKS BOTH FRONT AND BACK THERMOSTAT HOUSINGS TO THE WALL - ELEGANT STYLE AND SECURITY AT AN AFFORDABLE PRICE WALL PLATE FOR LX-SERIES THERMOSTATS - EASILY COVER PAINT DISCREPANCIES OR WALL BLEMISHES LEFT AFTER REMOVAL OF OLD THERMOSTATS - SLIM, ATTRACTIVE DESIGN ADD-A-WIRE ACCESSORY FOR ALL CONVENTIONAL THERMOSTATS - ONE WIRE TO RUN TWO WIRES WORTH OF COMMUNICATION IN APPLICATIONS WHERE ADDITIONAL WIRE CANNOT BE RUN

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

$ 85.71

62.50

196.43

83.93

28.57

16.07

41.96

55


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL & COMMERCIAL ACCESSORY THERMOSTATS Additional LX-Series Accessories Coming Soon: SOURCE 1 PART NO.

DESCRIPTION

MLP

ADD-A-WIRELESS-THERMOSTAT FOR LX-SERIES THERMOSTATS (REQUIRES WIRELESS TRANSCEIVER MODULE) - WORKS WITH LX-SERIES THERMOSTATS (MODELS S1-THSU32P7 AND S1-THSU32HP7) LIKE A REMOTE CONTROL - MONITOR AND ADJUST THE TEMPERATURE OF ANY ROOM IN THE HOUSE FROM ANYWHERE IN THE HOUSE S1-LXADDSTAT - CONTROL ALTERNATES BETWEEN BASE THERMOSTAT AND REMOTE BASED ON LAST BUTTON PUSHED - EASY 5-MINUTE INSTALLATION - BACKLIT DISPLAY INTERNET GATEWAY SYSTEM FOR LX-SERIES THERMOSTATS (REQUIRES WIRELESS TRANSCEIVER MODULE) S1-LXIGS - ENABLES REMOTE MONITORING AND CONTROL VIA THE INTERNET

TBD

TBD

RESIDENTIAL ACCESSORY THERMOSTATS

Source 1 Value Series Thermostats Features: • Large digital display; programmable models are backlit • Up to 2 stages heating and 2 stages cooling • Battery or system powered • Auxiliary heat indicator for heat pump models • Fahrenheit or Celsius • Separate mounting plate • Manual changeover (except S1THEM22P7S)

SOURCE 1 PART NO. S1-THEC11NS S1-THEC11P5S S1-THEH21NS S1-THEH21P5S S1-THEU22P7S S1-THEM22P7S

STAGES HEAT COOL 1 1 2 2

2

PROGRAM N/A 5-2 DAY N/A 5-2 DAY 7 DAY

• Custom contractor logo available on battery covers for battery-powered models. Order S1-THEBATTCVR. • Commercial model includes autochangeover, clock backup, up to 4-hour override, and keypad lockout Accessories: • Locking cover ring (S1-THELOCK, see p. 56) • Decorative wall mounting backplate (S1THEPLATE, see p. 56) • Add-a-Wire Accessory (S1-ADDWIRE, see p. 56) POWER SOURCE

APPLICATIONS SINGLE-STAGE HEAT PUMP, GAS/OIL/ELECTRIC, MILLIVOLT HEAT PUMP OR CONVENTIONAL MULTI-STAGE HEAT PUMP, GAS/OIL/ELECTRIC COMMERCIAL MULTI-STAGE HEAT PUMP, GAS/OIL/ELECTRIC

HARDWIRED OR BATTERY HARDWIRED

MLP $ 60.71 76.79 80.36 98.21 142.86 160.71

Value Series Thermostat Accessories

S1-ADDWIRE S1-THEPLATE SI-THELOCK SOURCE 1 PART NO. S1-THELOCK S1-THEPLATE NEW

56

S1-ADDWIRE

DESCRIPTION

MLP

LOCKING COVER FOR S1-THE SERIES THERMOSTATS WALL MOUNTING PLATE FOR S1-THE SERIES THERMOSTATS ADD-A-WIRE ACCESSORY FOR ALL CONVENTIONAL THERMOSTATS

$28.57 7.14

STOCKED NON STOCKED

41.96

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COMMERCIAL PROGRAMMABLE THERMOSTATS

York Touch-Screen Commercial Programmable Thermostat

The Touchscreen Programmable Thermostat is an effortless, seven-day programmable thermostat that provides universal system compatibility, precise comfort control and is easy to program. SOURCE 1 PART NO.

S1-2ET07700524

It provides temperature control for gas, oil, electric and heat pumps for up to 2 heat, 2 cool systems. Features: • Large, clear display with backlight shows the current and set temperature and time—even in the dark • Menu-driven programming makes setup effortless • Beautiful ergonomic design is smart and sophisticated to match your customers’ lifestyles • Touchscreen interaction • Real-time clock keeps time during power failures and automatically updates to daylight savings • “Saving Changes” notification lets you know when the schedule changes have been saved

• Change reminders let you know when to replace the batteries • Holiday Override options allow you to override the program schedule, as desired • Speedy same-schedule programming—no need to copy multiple days • Armchair programming allows you to remove the thermostat from the wall for programming Specifications: Electrical Ratings: Voltage: 20–30 VAC at 50/60 Hz; Running Current: 0.02–1.0A (Fan 0.02– 0.60A) Temperature Setting Ranges: Heating: 40°–90°F (4°–32°C) Cooling: 50°–99°F (10°–37°C) Humidity Ratings: 5%–90% RH non-condensing

DESCRIPTION

APPLICATIONS

MLP

TOUCH-SCREEN COMMERCIAL PROGRAMMABLE THERMOSTAT

GAS OR ELECTRIC HEAT WITH AIR CONDITIONING WARM AIR, HOT WATER, HIGH-EFFICIENCY FURNACES, AND HEAT PUMPS HEAT ONLY HEAT ONLY WITH FAN COOL ONLY

$436.43

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

57


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

York Touch-Screen Thermostats

S1-2PP32U70124 The S1-2PP32U70124 Universal Programmable Thermostats provide electronic control of 24 VAC heating and cooling systems or 750 mV heating systems. Features: • Large, Clear Display with Backlighting current temperature, set temperature and time are easy-to-read and all are displayed on the home screen. • Menu Driven Programming Guides you through the scheduling process, showing only necessary information and choices on each screen.

• Ability to Select Multiple Days allows you to easily customize the thermostat for your unique schedule. • Real-Time Clock keeps time during power failure; automatically updates for daylight savings. • Armchair Programming allows you to remove thermostat from wall to set the schedule. • Precise Temperature Control (+/- 1 F) reliable, consistent comfort. • Multiple HOLD options allows you to modify schedule indefinitely or for a specific time. • Change Reminders reminds you to service or replace the air filter, humidifier pad, ultraviolet lamp or thermostat batteries. • Programmable Fan increases air quality when combined with a whole-house air cleaner. • Outdoor Temperature Indication (Select Models) shows current outdoor temperature on the display to help you plan outdoor activities. Specifications: Application: Heating and Cooling systems Programmability: Universal Programming from 7 Day to Non-Programmable Changeover: Automatic Color: Premier White®

Switch Positions (System): HEAT-OFFCOOL-AUTO Switch Positions (Fan): AUTO-ON Power Method: Battery or Hardwired Dimensions (in.): 4-9/16”H x 6”W x 1-1/4”D Mounting: Horizontal Electrical Ratings: 20 to 30 VAC Frequency: 60 Hz; 50 Hz Setting Temperature Range (F): Heat: 40°F to 90°F; Cool: 50°F to 99°F Setting Temperature Range (C): Heat: 4.5°C to 32°C; Cool: 10°C to 37°C Differential Temperature (F): 1°F Differential Temperature (C): 0.5°C Stages: Up to 1 Heat/1 Cool Outdoor Sensor: Yes, optional outdoor remote (S1-C7089U1006, p. 76). Remote Sensor: Yes, optional indoor remote (S1-C7189U1005, p. 76). Sensor Element: Thermistor Currents (Heating): 1.0 A running Currents (Cooling): 1.0 A running Currents (Fan): 0.6A running Humidity Ratings (%RH): 5 to 90% RH, noncondensing

Programmable SOURCE 1 PART NO. S1-2PP32U70124

58

STAGES

DEHUMIDIFICATION CONTROL

MLP

UP TO 3 HEAT/2 COOL

YES

$362.70

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL & COMMERCIAL ACCESSORY THERMOSTATS

York LX-Series Thermostats Available March 2009 •

• •

Source 1 LX-Series thermostats are suitable for residential or commercial gas/electric, heat pump, multistage, and hydronic systems. They offer an extraordinarily rich set of features. A variety of matching accessories offer extended functionality to the dealer and the home or building owner. Features: • Large (4.7 sq in) digital display with soft white adjustable intensity backlight displays current indoor and outdoor (with optional remote STAGES HEAT

SOURCE 1 PART NO.

• • • • • • • • • • •

sensor) temperature, setpoints, day of week, and time Adjustable scrolling10-character 16-element marquee text guides through setup and programming steps in plain language and allows customizable service alerts and error messages Bicolor LED mode indicator and backlit, color-coded soft-touch keys Programmable models meet Energy Star and California Title 24 specifications Up to 4 stages heating and 2 stages cooling Up to 7-day installer selectable programming Auto changeover (switchable to manual) Built-in compressor protection (defeatable for zoning applications) Adjustable timers and deadbands Auxiliary heat indicator Auxiliary heat lockout Fahrenheit/Celsius display Service filter reminder UV lamp replacement reminder Remote temperature sensor ready

COOL

PROGRAMMING OPTIONS

2

1

1-DAY, NONE

3 (4 FOR HEATPUMP)

2

7-DAY, 5+2 DAY, 1-DAY, NONE

• Programmer compatible • Wireless accessories (see p. 55 for compatible accessories) • Humidification and dehumidification (some models) • Dual fuel capable (some models) Specifications: Power Method: Hardwired Electrical Ratings: 24 VAC ±15% Frequency: 60Hz; 50Hz Terminal Load: Y1, Y2, G 1.5 A per terminal; all others 0.5 A per terminal Setpoint Temperature Range (heating): 35°– 99°F (1.5°–37°C) Setpoint Temperature Range (cooling): 35°– 99°F (1.5°–37°C) Deadband Differential: 1°–6°F (0.5°–3.0°C) Operating Ambient: 35°–105°F (1.5°–41°C) Operating Humidity: 5–90% RH, non-condensing Dimensions: 4-3/8” H x 5-5/16” W x 1” D Mounting: Horizontal Accessories: see p. 55

CONTROL

TERMINALS

MLP

RESIDENTIAL MODELS NEW

S1-THSU21P1Y

NEW

S1-THSU32P7Y

HUMIDIFICATION, DEHUMIDIFICATION, REHEAT, AND DUAL FUEL

NEW S1-THSU32HP7Y

R, C, G, W1/O/B, W2, Y1, OUTDOOR SENSOR, $123.21 DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, 185.71 REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, HUM, DEHUM, AUX, 232.14 OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

COMMERCIAL MODELS NEW

S1-TBSU22HNY

NEW

S1-TBSU32P7Y

2

NON-PROGRAMMABLE

HUMIDIFICATION, AND DEHUMIDIFICATION

2 3 (4 FOR HEATPUMP)

NEW S1-TBSU32HP7Y

7-DAY, 5+2 DAY, 1-DAY, NONE HUMIDIFICATION, DEHUMIDIFICATION, AND REHEAT

R, C, G, W1/O/B, W2, Y1, Y2, HUM, DEHUM, OUTDOOR SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, AUX, HUM, DEHUM, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

$189.29

196.43

239.29

59


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

York Value Series Thermostats Features: • Large digital display; programmable models are backlit • Up to 2 stages heating and 2 stages cooling • Battery or system powered • Auxiliary heat indicator for heat pump models • Fahrenheit or Celsius • Separate mounting plate • Manual changeover (except S1THEM22P7Y) SOURCE 1 PART NO. S1-THEC11NY S1-THEC11P5Y S1-THEH21NY S1-THEH21P5Y S1-THEU22P7Y S1-THEM22P7Y

60

STAGES HEAT COOL 1 1 2 2

PROGRAM N/A 5-2 DAY N/A 5-2 DAY

2

• Custom contractor logo available on battery covers for battery-powered models • Commercial model includes autochangeover, clock backup, up to 4-hour override, and keypad lockout Accessories: • Locking cover ring (S1-THELOCK, see p. 56) • Decorative wall mounting backplate (S1THEPLATE, see p. 56) • Add-a-Wire Accessory (S1-ADDWIRE, see p. 56)

APPLICATIONS SINGLE-STAGE HEAT PUMP, GAS/OIL/ELECTRIC, MILLIVOLT HEAT PUMP OR CONVENTIONAL MULTI-STAGE HEAT PUMP, GAS/OIL/ELECTRIC COMMERCIAL MULTI-STAGE HEAT PUMP, GAS/OIL/ELECTRIC

STOCKED NON STOCKED

POWER SOURCE HARDWIRED OR BATTERY HARDWIRED

MLP $ 60.71 76.79 80.36 98.21 142.86 160.71

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

Touch-Screen Thermostats

S1-6PP32U70124 The S1-6PP32U70124 Universal Programmable Thermostats provide electronic control of 24 VAC heating and cooling systems or 750 mV heating systems. Features: • Large, Clear Display with Backlighting current temperature, set temperature and time are easy-to-read and all are displayed on the home screen. • Menu Driven Programming Guides you through the scheduling process, showing only necessary information and choices on each screen.

• Ability to Select Multiple Days allows you to easily customize the thermostat for your unique schedule. • Real-Time Clock keeps time during power failure; automatically updates for daylight savings. • Armchair Programming allows you to remove thermostat from wall to set the schedule. • Precise Temperature Control (+/- 1 F) reliable, consistent comfort. • Multiple HOLD options allows you to modify schedule indefinitely or for a specific time. • Change Reminders reminds you to service or replace the air filter, humidifier pad, ultraviolet lamp or thermostat batteries. • Programmable Fan increases air quality when combined with a whole-house air cleaner. • Outdoor Temperature Indication (Select Models) shows current outdoor temperature on the display to help you plan outdoor activities. Specifications: Application: Heating and Cooling systems Programmability: Universal Programming from 7 Day to Non-Programmable Changeover: Automatic Color: Premier White®

Switch Positions (System): HEAT-OFFCOOL-AUTO Switch Positions (Fan): AUTO-ON Power Method: Battery or Hardwired Dimensions (in.): 4-9/16”H x 6”W x 1-1/4”D Mounting: Horizontal Electrical Ratings: 20 to 30 VAC Frequency: 60 Hz; 50 Hz Setting Temperature Range (F): Heat: 40°F to 90°F; Cool: 50°F to 99°F Setting Temperature Range (C): Heat: 4.5°C to 32°C; Cool: 10°C to 37°C Differential Temperature (F): 1°F Differential Temperature (C): 0.5°C Stages: Up to 1 Heat/1 Cool Outdoor Sensor: Yes, optional outdoor remote (S1-C7089U1006, p. 76). Remote Sensor: Yes, optional indoor remote (S1-C7189U1005, p. 76). Sensor Element: Thermistor Currents (Heating): 1.0 A running Currents (Cooling): 1.0 A running Currents (Fan): 0.6A running Humidity Ratings (%RH): 5 to 90% RH, noncondensing

Programmable SOURCE 1 PART NO. S1-6PP32U70124

STAGES

DEHUMIDIFICATION CONTROL

MLP

UP TO 3 HEAT/2 COOL

YES

$362.70

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

61


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL & COMMERCIAL ACCESSORY THERMOSTATS

LX-Series Thermostats Available March 2009 •

• •

Source 1 LX-Series thermostats are suitable for residential or commercial gas/electric, heat pump, multistage, and hydronic systems. They offer an extraordinarily rich set of features. A variety of matching accessories offer extended functionality to the dealer and the home or building owner. Features: • Large (4.7 sq in) digital display with soft white adjustable intensity backlight displays current indoor and outdoor (with optional remote SOURCE 1 PART NO.

STAGES HEAT

• • • • • • • • • • •

sensor) temperature, setpoints, day of week, and time Adjustable scrolling10-character 16-element marquee text guides through setup and programming steps in plain language and allows customizable service alerts and error messages Bicolor LED mode indicator and backlit, color-coded soft-touch keys Programmable models meet Energy Star and California Title 24 specifications Up to 4 stages heating and 2 stages cooling Up to 7-day installer selectable programming Auto changeover (switchable to manual) Built-in compressor protection (defeatable for zoning applications) Adjustable timers and deadbands Auxiliary heat indicator Auxiliary heat lockout Fahrenheit/Celsius display Service filter reminder UV lamp replacement reminder Remote temperature sensor ready

COOL

PROGRAMMING OPTIONS

2

1

1-DAY, NONE

3 (4 FOR HEATPUMP)

2

7-DAY, 5+2 DAY, 1-DAY, NONE

• Programmer compatible • Wireless accessories (see p. 55 for compatible accessories) • Humidification and dehumidification (some models) • Dual fuel capable (some models) Specifications: Power Method: Hardwired Electrical Ratings: 24 VAC ±15% Frequency: 60Hz; 50Hz Terminal Load: Y1, Y2, G 1.5 A per terminal; all others 0.5 A per terminal Setpoint Temperature Range (heating): 35°– 99°F (1.5°–37°C) Setpoint Temperature Range (cooling): 35°– 99°F (1.5°–37°C) Deadband Differential: 1°–6°F (0.5°–3.0°C) Operating Ambient: 35°–105°F (1.5°–41°C) Operating Humidity: 5–90% RH, non-condensing Dimensions: 4-3/8” H x 5-5/16” W x 1” D Mounting: Horizontal Accessories: see p. 55

CONTROL

TERMINALS

MLP

RESIDENTIAL MODELS NEW

S1-THSU21P1C

NEW

S1-THSU32P7C

HUMIDIFICATION, DEHUMIDIFICATION, REHEAT, AND DUAL FUEL

NEW S1-THSU32HP7C

R, C, G, W1/O/B, W2, Y1, OUTDOOR SENSOR, $123.21 DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, 185.71 REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, HUM, DEHUM, AUX, 232.14 OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

COMMERCIAL MODELS NEW

S1-TBSU22HNC

NEW

S1-TBSU32P7C

2

HUMIDIFICATION, AND DEHUMIDIFICATION

2 3 (4 FOR HEATPUMP)

7-DAY, 5+2 DAY, 1-DAY, NONE HUMIDIFICATION, DEHUMIDIFICATION, AND REHEAT

NEW S1-TBSU32HP7C

62

NON-PROGRAMMABLE

STOCKED NON STOCKED

R, C, G, W1/O/B, W2, Y1, Y2, HUM, DEHUM, OUTDOOR SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, AUX, HUM, DEHUM, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

$189.29

196.43

239.29

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

Value Series Thermostats Features: • Large digital display; programmable models are backlit • Up to 2 stages heating and 2 stages cooling • Battery or system powered • Auxiliary heat indicator for heat pump models • Fahrenheit or Celsius • Separate mounting plate SOURCE 1 PART NO. S1-THEC11NC S1-THEC11P5C S1-THEH21NC S1-THEH21P5C

STAGES HEAT COOL 1 1 2

PROGRAM N/A 5-2 DAY N/A 5-2 DAY

• Manual changeover • Custom contractor logo available on battery covers Accessories: • Locking cover ring (S1-THELOCK, see p. 56) • Decorative wall mounting backplate (S1THEPLATE, see p. 56) • Add-a-Wire Accessory (S1-ADDWIRE, see p. 56) POWER SOURCE

APPLICATIONS SINGLE-STAGE HEAT PUMP, GAS/OIL/ELECTRIC, MILLIVOLT HEAT PUMP OR CONVENTIONAL

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

HARDWIRED OR BATTERY

MLP $60.71 76.79 80.36 98.21

63


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

Touch-Screen Thermostats

S1-4PP32U70124 The S1-4PP32U70124 Universal Programmable Thermostats provide electronic control of 24 VAC heating and cooling systems or 750 mV heating systems. Features: • Large, Clear Display with Backlighting current temperature, set temperature and time are easy-to-read and all are displayed on the home screen. • Menu Driven Programming Guides you through the scheduling process, showing only necessary information and choices on each screen.

• Ability to Select Multiple Days allows you to easily customize the thermostat for your unique schedule. • Real-Time Clock keeps time during power failure; automatically updates for daylight savings. • Armchair Programming allows you to remove thermostat from wall to set the schedule. • Precise Temperature Control (+/- 1 F) reliable, consistent comfort. • Multiple HOLD options allows you to modify schedule indefinitely or for a specific time. • Change Reminders reminds you to service or replace the air filter, humidifier pad, ultraviolet lamp or thermostat batteries. • Programmable Fan increases air quality when combined with a whole-house air cleaner. • Outdoor Temperature Indication (Select Models) shows current outdoor temperature on the display to help you plan outdoor activities. Specifications: Application: Heating and Cooling systems Programmability: Universal Programming from 7 Day to Non-Programmable Changeover: Automatic Color: Premier White®

Switch Positions (System): HEAT-OFFCOOL-AUTO Switch Positions (Fan): AUTO-ON Power Method: Battery or Hardwired Dimensions (in.): 4-9/16”H x 6”W x 1-1/4”D Mounting: Horizontal Electrical Ratings: 20 to 30 VAC Frequency: 60 Hz; 50 Hz Setting Temperature Range (F): Heat: 40°F to 90°F; Cool: 50°F to 99°F Setting Temperature Range (C): Heat: 4.5°C to 32°C; Cool: 10°C to 37°C Differential Temperature (F): 1°F Differential Temperature (C): 0.5°C Stages: Up to 1 Heat/1 Cool Outdoor Sensor: Yes, optional outdoor remote (S1-C7089U1006, p. 76). Remote Sensor: Yes, optional indoor remote (S1-C7189U1005, p. 76). Sensor Element: Thermistor Currents (Heating): 1.0 A running Currents (Cooling): 1.0 A running Currents (Fan): 0.6A running Humidity Ratings (%RH): 5 to 90% RH, noncondensing

Programmable SOURCE 1 PART NO. S1-4PP32U70124

64

STAGES

DEHUMIDIFICATION CONTROL

MLP

UP TO 3 HEAT/2 COOL

YES

$362.70

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL & COMMERCIAL ACCESSORY THERMOSTATS

LX-Series Thermostats Available March 2009 •

• •

Source 1 LX-Series thermostats are suitable for residential or commercial gas/electric, heat pump, multistage, and hydronic systems. They offer an extraordinarily rich set of features. A variety of matching accessories offer extended functionality to the dealer and the home or building owner. Features: • Large (4.7 sq in) digital display with soft white adjustable intensity backlight displays current indoor and outdoor (with optional remote STAGES HEAT

SOURCE 1 PART NO.

• • • • • • • • • • •

sensor) temperature, setpoints, day of week, and time Adjustable scrolling10-character 16-element marquee text guides through setup and programming steps in plain language and allows customizable service alerts and error messages Bicolor LED mode indicator and backlit, color-coded soft-touch keys Programmable models meet Energy Star and California Title 24 specifications Up to 4 stages heating and 2 stages cooling Up to 7-day installer selectable programming Auto changeover (switchable to manual) Built-in compressor protection (defeatable for zoning applications) Adjustable timers and deadbands Auxiliary heat indicator Auxiliary heat lockout Fahrenheit/Celsius display Service filter reminder UV lamp replacement reminder Remote temperature sensor ready

COOL

PROGRAMMING OPTIONS

2

1

1-DAY, NONE

3 (4 FOR HEATPUMP)

2

7-DAY, 5+2 DAY, 1-DAY, NONE

• Programmer compatible • Wireless accessories (see p. 55 for compatible accessories) • Humidification and dehumidification (some models) • Dual fuel capable (some models) Specifications: Power Method: Hardwired Electrical Ratings: 24 VAC ±15% Frequency: 60Hz; 50Hz Terminal Load: Y1, Y2, G 1.5 A per terminal; all others 0.5 A per terminal Setpoint Temperature Range (heating): 35°– 99°F (1.5°–37°C) Setpoint Temperature Range (cooling): 35°– 99°F (1.5°–37°C) Deadband Differential: 1°–6°F (0.5°–3.0°C) Operating Ambient: 35°–105°F (1.5°–41°C) Operating Humidity: 5–90% RH, non-condensing Dimensions: 4-3/8” H x 5-5/16” W x 1” D Mounting: Horizontal Accessories: see p. 55

CONTROL

TERMINALS

MLP

RESIDENTIAL MODELS NEW

S1-THSU21P1L

NEW

S1-THSU32P7L

HUMIDIFICATION, DEHUMIDIFICATION, REHEAT, AND DUAL FUEL

NEW S1-THSU32HP7L

R, C, G, W1/O/B, W2, Y1, OUTDOOR SENSOR, $123.21 DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, 185.71 REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, HUM, DEHUM, AUX, 232.14 OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

COMMERCIAL MODELS NEW

S1-TBSU22HNL

NEW

S1-TBSU32P7L

2

NON-PROGRAMMABLE

HUMIDIFICATION, AND DEHUMIDIFICATION

2 3 (4 FOR HEATPUMP)

NEW S1-TBSU32HP7L

7-DAY, 5+2 DAY, 1-DAY, NONE HUMIDIFICATION, DEHUMIDIFICATION, AND REHEAT

R, C, G, W1/O/B, W2, Y1, Y2, HUM, DEHUM, OUTDOOR SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT R, C, G, W1/O/B, W2, W3, Y1, Y2, AUX, HUM, DEHUM, OUTDOOR SENSOR, REMOTE SENSOR, DRY CONTACT, FAULT

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

$189.29

196.43

239.29

65


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

Value Series Thermostats Features: • Large digital display; programmable models are backlit • Up to 2 stages heating and 2 stages cooling • Battery or system powered • Auxiliary heat indicator for heat pump models • Fahrenheit or Celsius • Separate mounting plate SOURCE 1 PART NO. S1-THEC11NL S1-THEC11P5L S1-THEH21NL S1-THEH21P5L

66

STAGES HEAT COOL 1 1 2

PROGRAM N/A 5-2 DAY N/A 5-2 DAY

• Manual changeover • Custom contractor logo available on battery covers Accessories: • Locking cover ring (S1-THELOCK, see p. 56) • Decorative wall mounting backplate (S1THEPLATE, see p. 56) • Add-a-Wire Accessory (S1-ADDWIRE, see p. 56)

APPLICATIONS SINGLE-STAGE HEAT PUMP, GAS/OIL/ELECTRIC, MILLIVOLT HEAT PUMP OR CONVENTIONAL

STOCKED NON STOCKED

POWER SOURCE HARDWIRED OR BATTERY

MLP $60.71 76.79 80.36 98.21

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL ACCESSORY THERMOSTATS

White-Rodgers 90 Series™ Blue Universal Touchscreen Thermostats Features: • Automatic heat/cool changeover option • Installer-selectable system applications and programs • 12-square-inch lighted display is the largest in the industry • 4 time and 4 temperature settings per program (2 setbacks) heat and cool, or selectable—2 time and 2 temperature settings (1 setback) • Selectable Energy Management Recovery • Permanent program retention during power outages • Compressor lockout protection • Maintains room temperature to within ±1° • Programmable Fan and Remote Sensing available for S1-1F95-1277 and S1-1F971277

SOURCE 1 PART NO.

SYSTEM/STAGES (HEAT/COOL) SINGLE MULTI HEAT STAGE STAGE PUMP

APPLICATION SINGLE-STAGE HEAT PUMP, GAS/OIL/ELECTRIC, MILLIVOLT

S1-1F97-1277

SOURCE 1 PART NO. S1-F145-1378 S1-F145-1328

1/1

1/1

Specifications: Dimensions: 4.6”H x 5.9”W x 1.2”D Setpoint Temperature Range: 45°–99°F (7– 32°C) Rated Differential: Heat 0.6°F; Cool 1.2°F Operating Ambient Temperature: 32°–105°F (0°–41°C) Operating Humidity Range: 90% non-condensing maximum Electrical: Battery: mV to 30 VAC, NEC Class II, 50/60 Hz or DC Input-Hardwire: 20–30 VAC 1.5A load per terminal; 2.5A maximum load (all terminals combined)

PROGRAM

MLP

7, 5/1/1, 0

298.04

DESCRIPTION

MLP

OUTDOOR TEMPERATURE SENSOR INDOOR TEMPERATURE SENSOR

$80.46 69.37

White-Rodgers 80 Series™ Blue Single Stage Thermostats Features: • Configures as manual heat/cool, auto changeover, heat only or cool only • Exclusive Cool Savings™ feature saves energy during peak A/C demand periods • Hydronic 2- or 3-wire applications • Three anticipation settings • Exclusive battery power monitor • Easy access battery compartment • Permanent program retention during power loss Specifications: Dimensions: 4.5”W x 3.5”H x 1.1”D Electrical: Rating 0–30 VAC, 50/60 Hz or DC SOURCE 1 PART NO.

SYSTEM/STAGES SINGLE MULTI HEAT STAGE STAGE PUMP

S1-1F85-0471 1/1 S1-1F83-0471

2/2

3/2

Load (per terminal): 0.05–1.0 A Load (all terminals combined): 1.5 A maximum Setpoint Temperature Range: 45°–90°F (7°– 32°C) Differential: 0.4°–1.7°F with adjustable anticipation Operating Ambient Temperature: 32°–105°F (0°–40°C) Operating Humidity Range: 90% non-condensing maximum Accessories: Wall plate, 6.5”W x 5”H (vendor part number F61-2634) included with S1-1F800471

PROGRAM

APPLICATION

POWER

5+1+1, 5+2 OR 0

SINGLE STAGE HEAT PUMP MULTI-STAGE HEAT PUMP SINGLE STAGE HEAT PUMP MULTI-STAGE HEAT PUMP

BATTERY, HARDWIRED

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

MLP $219.64 174.82

67


hemrichelectric.com

info@hemrichelectric.com

WHITE RODGERS DIGITAL THERMOSTATS

Comfort Set® 80 Series Digital Thermostats • • • •

Comfort Set® 80 Series Digital Thermostats deliver both accuracy and control. By maintaining a set temperature to within one degree, they eliminate temperature swings that cost both comfort and energy savings. Larger permanent memory improves performance, and saves all programs during a power loss. Plus, their 60% larger lighted display makes viewing easy, even in low-light situations, while the ergonomic design gives you easy access to keypad controls for ease in set-up and programming. Features: • Patented pre-programmed software simplifies time and temperature programming. • Infinite setpoint Hold, or programmable timed Hold up to 8 hours. • Temporary temperature override until next program period. SOURCE 1 PART NO.

Soft touch keypad. Display temperature recalibration (±4°). Powerful “next generation” microprocessor. Fast (FA) or slow (SL) heating cycle anticipation. • Selectable Energy Management Recovery. • Air filter change indicator (optional on Single Stage). • Compressor lockout protection (optional on Heat Pumps). • Simple menu to activate optional features. • Meet Energy Star® specifications. • Meet California Building Code, Title 24. • Dimensions: 3-8/10”H x 6-1/10”W x 1-1/10”D • Accessories (not included): Wall Plate, 7-6/ 10” x 4-8/10”, (vendor part number F612500); Thermostat Guard (see pp. 78–78). • Permanent Program Retention during power loss. No batteries required. SINGLE STAGE Dual-Hardwired/Battery Digital 5/2 Day Programmable and Non-Programmable Electrical Specifications: Rating: 18 to 30 VAC, 50/60 Hz or DC 0.05 to 1.0 A (load per terminal), 1.5 A maximum load (all terminals combined). Standard Systems: Single stage gas, oil, electric; Single stage heat pump Thermal Specifications: STAGES

APPLICATION

HEAT

COOL

PROGRAM

POWER

2

2

0 OR 5/1/1

DUAL/ BATTERY

2 2

1 1

0 5/1/1 0

HARDWIRED HARDWIRED DUAL BATTERY/ HARDWIRED DUAL BATTERY/ HARDWIRED

S1-1F89-211 S1-1F82-261

UNIVERSAL SINGLE STAGE MULTI-STAGE OR HEAT PUMP HEAT PUMP HEAT PUMP

S1-1F83-261

ELECTRIC, GAS/OIL

2

2

S1-1F81-261

ELECTRIC, GAS/OIL

2

2

S1-1F80-361

GAS/OIL/ELECTRIC MILLIVOLT; DUAL-POWERED

S1-1F85-275

S1-1F86-344

68

1

1

5/1/1 5+1+1 —

HARDWIRED BATTERY

STOCKED NON STOCKED

Setpoint Temperature Range: 45°F to 90°F (7°C to 32°C) Rated Differential: 0.3°F to 1.9°F with adjustable anticipation Operating Ambient Temperature: 32°F to 105°F (0°C to 40°C) Operating Humidity Range: 90% non-condensing max Shipping Temperature Range: –40°F to 150°F (–40°C to 65°C) HEAT PUMP Hardwired Digital 5/1/1 Day Programmable and Non-Programmable Electrical Specifications: Rating: 20 to 30 VAC, 50/60 Hz or DC 0.05 to 1.0 A (load per terminal); 1.5 A maximum load (all terminals combined) Standard Systems: Heat Pump—2 stage heat, 1 stage cool; Single stage heat pump Thermal Specifications: Setpoint Temperature Range: 45°F to 90°F (7°C to 32°C) Rated Differential: 0.6°F to 1.6°F with adjustable anticipation Operating Ambient Temperature: 32°F to 105°F (0°C to 40°C) Operating Humidity Range: 90% non-condensing max Shipping Temperature Range: –4°F to 150°F (–20°C to 65°C)

ENERGY MANAGEMENT RECOVERY

TERMINATIONS

MLP

YES

R,C,G,W1,W2,Y1,Y2,L,O,B

$177.44

— NO

R, C, Y, W2, G, B/O, L, E R, C, G, Y, W2, E, O/B, L

121.43 148.50

R, C, Y, Y2, W, W2, G

162.84

YES

R, C, Y, Y2, W, W2, G

YES —

RC, RH, C, W, Y, G, O, B

180.84 140.55 92.74

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

WHITE RODGERS DIGITAL THERMOSTATS

Comfort Set® 70 Series Digital Thermostats

S1-1F73-174

The 70 Series Thermostat allows customers to economically upgrade to digital accuracy and energy savings…without the need for decoratSOURCE 1 PART NO. S1-1F73-174

ing touch-ups. Its new low-profile design covers the footprint of the four most common mechanical thermostats in use today—so there’s no need to repaint or spackle the walls around it. And it’s battery powered, making it easy to install and compatible with most heating/cooling systems. Features: • Choice of 5/2 day programming (weekday/ weekend), or non-programmable. • Large, easy-to-read LCD thermostat display. • Electronic temperature accuracy. • Adjustable room temperature calibration. • Millivolt compatible. • Dimensions: 3-1/2”H x 5-1/10”W x 1-1/10”D. • Accessories: Thermostat Guard. STAGES

APPLICATION UNIVERSAL MULTI-STAGE HEAT PUMP

HEAT 2

COOL

PROGRAM

POWER

Electrical Specifications: Rating: 0 to 30 VAC, 50/60 Hz or DC 0.05 to 1.2 A (load per terminal); 1.5 A maximum load (all terminals combined). Standard Systems: Single stage gas, oil, electric; Single stage heat pump Thermal Specifications: Setpoint Temperature Range: 45°F to 90°F (7°C to 32°C) Rated Differential: 0.6°F to 1.9°F with adjustable anticipation Operating Ambient Temperature: 32°F to 105°F (0°C to 40°C) Operating Humidity Range: 90% non-condensing max Shipping Temperature Range: –40°F to 150°F (–40°C to 65°C) ENERGY MANAGEMENT RECOVERY

2

0

HARDWIRED

TERMINATIONS R, C, W, W2, G, Y, Y2, O/B R, C, Y, W2, G, B/O, L, E R, C, Y, W2, G, B/O, L, E

MLP $115.20

S1-1F72-151

HEAT PUMP

2

1

5/2

HARDWIRED

YES

S1-1F79-111

HEAT PUMP

2

1

0

HARDWIRED

1

1

0

BATTERY INCLUDED

RC, RH, W, Y, G

72.35

1

1

5/2

BATTERY INCLUDED

NO

RC, RH, W, Y, G

83.77

S1-1F78-144 S1-1F78-151 S1-1F78H-144 S1-1F78H-151 S1-1E78-140 S1-1E78-144

ELECTRIC, GAS/OIL, HEAT PUMP, MILLIVOLT ELECTRIC, GAS/OIL, HEAT PUMP, MILLIVOLT ELECTRIC, GAS/OIL, HEAT PUMP, MILLIVOLT ELECTRIC, GAS/OIL, HEAT PUMP, MILLIVOLT SINGLE STAGE GAS/OIL/ ELECTRIC, MILLIVOLT SINGLE STAGE GAS/OIL/ ELECTRIC, MILLIVOLT

RC, RH, W, Y, G, O, B RC, RH, W, Y, G, O, B

114.25 97.11

1

1

0

HARDWIRED

1

1

5/2

HARDWIRED

NO

1

0

0

BATTERY INCLUDED

RH, W

64.50

RC, RH, W, Y G, O, B

68.53

1

1

0

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

60.71 72.32

69


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL DIGITAL THERMOSTATS

Vision Pro® IAQ Total Home Comfort System The VisionPro® IAQ Total Home Comfort System features an effortless, 7day programmable touchscreen thermostat that provides control of temperature, humidification, dehumidification, and ventilation. Features: • Large, clear display with backlight shows the current and set temperature and time—even in the dark • Touchscreen interaction • Real-time clock keeps time during power failures and automatically updates to daylight savings • Change/check reminders let you know when to service or replace filters • Various Hold options allow you to override the program schedule, as desired • Controls dehumidification using air conditioner with high or low speed fan or a whole house dehumidifier SOURCE 1 PART NO.

S1-YTH9421C1002

70

APPLICATIONS GAS/OIL/ELECTRIC HEAT WITH AIR CONDITIONING WARM AIR, HOT WATER, HIGH-EFFICIENCY FURNACES HEAT PUMPS STEAM AND GRAVITY HEAT ONLY WITH FAN, COOL ONLY

STOCKED NON STOCKED

• Controls ventilation with other HRV, ERV or Fresh air damper. Vent on demand and automatically using patented advanced ventilation control • Advanced heat pump control featuring balance point plus 2°F droop to increase homeowner comfort Specifications: Electrical Ratings: Voltage 20–30 VAC at 50/60 Hz; Running Current 0.02–1.0A Temperature Setting Range: Heating: 40°–90°F (4.5°–32°C); Cooling: 50°–99°F (10°–37°C) Humidification Setting Range: Heating, 10%–60% RH Dehumidification Setting Range: Heating: 40%–80% RH Humidity Display Range: 0%–99%

STAGES HEAT COOL

4

2

POWER SOURCE

COMMON WIRE ONLY

MLP

$463.22

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL DIGITAL THERMOSTATS

VisionPro® Universal Programmable Thermostat

The TH8110U Universal Programmable Thermostats provide electronic control of 24 VAC heating and cooling systems or 750 mV heating systems. Features: • Large, Clear Display with Backlighting current temperature, set temperature and time are easy-to-read and all are displayed on the home screen. • Menu Driven Programming Guides you through the scheduling process, showing only necessary information and choices on each screen. • Ability to Select Multiple Days allows you to easily customize the thermostat for your unique schedule. SOURCE 1 PART NO. S1-TH8110U1003 S1-TH8320U1008 S1-TH8321U1006

• Real-Time Clock keeps time during power failure; automatically updates for daylight savings. • Armchair Programming allows you to remove thermostat from wall to set the schedule. • Precise Temperature Control (+/- 1 F) reliable, consistent comfort. • Multiple HOLD options allows you to modify schedule indefinitely or for a specific time. • Change Reminders reminds you to service or replace the air filter, humidifier pad, ultraviolet lamp or thermostat batteries. • Programmable Fan increases air quality when combined with a whole-house air cleaner. • Outdoor Temperature Indication (Select Models) shows current outdoor temperature on the display to help you plan outdoor activities. Specifications: Application: Heating and Cooling systems Programmability: Universal Programming from 7 Day to Non-Programmable Changeover: Automatic Color: Premier White® Switch Positions (System): HEAT-OFFCOOL-AUTO

Switch Positions (Fan): AUTO-ON Power Method: Battery or Hardwired Dimensions (in.): 4-9/16”H x 6”W x 1-1/4”D Mounting: Horizontal Electrical Ratings: 20 to 30 VAC Frequency: 60 Hz; 50 Hz Setting Temperature Range (F): Heat: 40°F to 90°F; Cool: 50°F to 99°F Setting Temperature Range (C): Heat: 4.5°C to 32°C; Cool: 10°C to 37°C Differential Temperature (F): 1°F Differential Temperature (C): 0.5°C Stages: Up to 1 Heat/1 Cool Outdoor Sensor: Yes, optional outdoor remote (S1-C7089U1006, p. 76). Remote Sensor: Yes, optional indoor remote (S1-C7189U1005, p. 76). Sensor Element: Thermistor Currents (Heating): 1.0 A running Currents (Cooling): 1.0 A running Currents (Fan): 0.6A running Humidity Ratings (%RH): 5 to 90% RH, noncondensing

DESCRIPTION

TERMINAL DESIGNATIONS

DOWN SELECTABLE TO HEAT ONLY OR COOL ONLY WORKS WITH CONVENTIONAL AND HEAT PUMP SYSTEMS. EMERGENCY HEAT SWITCH POSITION AVAILABLE WHEN SETUP FOR HEAT PUMP SYSTEMS. THE L TERMINAL IS AN INPUT OR OUTPUT

R,RC,C,W,(O/B),Y,G,S1,S2 R,RC,C,W,Y,G,Y2,W2,S1,S2 FOR CONVENTIONAL SYSTEMS; R,RC,C,O/B,Y,Y2,G,L,E, AUX,S1,S2 FOR HEAT PUMP SYSTEMS

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

STAGES HEAT COOL UP TO 1

1

UP TO 3

2

MLP $327.31 368.22 405.28

71


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL DIGITAL THERMOSTATS

FocusPRO® TH6110, TH6220 & TH6320 Thermostats Features: • Separately programmable weekday/weekend schedules • One-touch temperature control overrides program schedule at any time • EnergyStar® compliant • Removable battery holder for fast, easy replacement • Built-in compressor protection

SOURCE 1 PART NO. S1-TH6110D1021 S1-TH6220D1028 S1-TH6320U1000

Specifications: Temperature Ranges: Heat 40°–90°F (4.5°– 32°C), Cool 50°–99°F (10°–37°C) Operating Ambient Temperature: 32°–120°F (0°–48.9°C) Operating Relative Humidity: 5%–90% (noncondensing) Dimensions: 3-9/16”H x 5-13/16”W x 1-1/2”D (91mmH x 147mmW x 38mmD)

STAGES PROGRAMS HEAT COOL

APPLICATION 24 VAC SINGLE-STAGE AND MULTI-STAGE HEATING AND COOLING SYSTEMS, OR 750 MV HEATING SYSTEMS

5+1+1

1 2 3

1 2 2

POWER

MLP

HARDWIRED $154.45 OR 191.04 BATTERY 200.72

Digital Non-Programmable FocusPRO® TH5110, TH5220 & TH5320 Thermostats

FocusPRO® non-programmable digital thermostats provide electronic control of 24 VAC conventional and heat pump systems or 750 mV heating systems. SOURCE 1 PART NO.

APPLICATION

S1-TH5110D1022 S1-TH5220D1029

24 VAC CONVENTIONAL & HEAT PUMP SYSTEMS; 750 MV HEATING SYSTEMS

S1-TH5320U1001

72

Features • Non-programmable digital thermostat. • Large, clear, backlit display - easy to read in various lighting conditions. • Display size options - available in large screen or standard. • Precise comfort control (±1°F) - maintains consistent comfort to the highest level of accuracy. • Easy change battery door - flip out door allows for easy battery replacement without removing or disassembling the thermostat. • 5-year limited warranty. Specifications: Mounting: Horizontal Changeover: Automatic/Manual Selectable TERMINAL DESIGNATIONS R, RC, C, W (O/B), Y, G RC, R, W (O/B), W2 (AUX), Y, Y2 (E), G, L, C RC, R, W (O/B), E/AUX, Y1, Y2, G, L, V

Color: Premier White® Power Method: Battery or Hardwired Fan Switch Positions: AUTO-ON Switch Type: Relay Setting Temperature Range: Heat: 40°F– 90°F; Cool: 50°F–99°F (Heat: 4.5°C–32°C; Cool: 10°C–37°C) Electrical Ratings: 20 to 30 VAC Frequency: 60 Hz; 50 Hz Sensor Element: Thermistor Ambient Temperature Range: 32°F–120°F (0°C–48.9°C Operating Humidity Range: 5 to 90% RH, non-condensing

SWITCH POSITIONS (SYSTEM)

DIMENSIONS

HEAT-OFFCOOL-AUTO

3-7/16”H X 4-1/2”W X 1-5/16”D (88MM H X 114MM W X 33MM D)

HEAT-OFF-COOLAUTO-EM.HEAT

3-9/16”H X 5-13/16”W X 1-1/2”D (99MM H X 147MM W X 38MM D)

STOCKED NON STOCKED

STAGES HEAT COOL

MLP

1

1

$118.69

2

2

161.11

3

2

186.25

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL DIGITAL THERMOSTATS

TH4000 Series Digital Thermostats Features: • Separately programmable weekday/weekend schedules • One-touch temperature control overrides program schedule at any time • Energy Star® compliant • Built-in compressor protection Specifications: Temperature Ranges: Heat 40°–90°F (4.5°– 32°C), Cool 50°–99°F (10°–37°C)

SOURCE 1 PART NO. S1-TH4110D1007 S1-TH4210D1005

Operating Ambient Temperature: 32°–120°F (0°–48.9°C) Operating Relative Humidity: 5%–90% (noncondensing) Dimensions: 3-13/16”H x 5-3/8”W x 1-1/4”D (97mmH x 137mmW x 32mmD) Electrical Ratings: 20–30 VAC, 0.02–1.0 A running current

APPLICATION

POWER

PROGRAMS

24 VAC SINGLE-STAGE HEATING AND COOLING SYSTEMS, OR 750 MV HEATING SYSTEMS. 24 VAC HEAT PUMP SYSTEMS WITH AUXILIARY HEAT (2 HEAT/1 COOL)

BATTERY COMMON WIRE COMMON WIRE WITH BATTERY BACKUP

5+2

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

STAGES HEAT COOL

MLP

1

1

$ 88.74

2

1

115.75

73


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL MECHANICAL THERMOSTATS

The Round® Mercury-Free Thermostat This thermostat features a precision electronic switch that completely eliminates the need for mercury, for environmentally-friendly performance. Precision, accuracy and reliability continue to be hallmarks of this popular, classic design.

SOURCE 1 PART NO.

STAGES HEAT COOL

DESCRIPTION

S1-T87N1000 S1-T87K1007

1 1

THE ROUND® MERCURY-FREE THERMOSTAT

1 0

MLP $109.00 73.53

HONEYWELL DIGITAL THERMOSTATS

Digital Round™ Thermostat

The T8775C Thermostat provides single-stage temperature control for 24V heating-cooling systems with manual changeover from heat to cool. Features: • Attractive styling complements any decor. • Large easy-to-read display. • The temperature reading is easily seen from a distance. • Backlit display. On-demand backlighting makes it easy to read the display in a dark room or hallway. • No batteries required. SOURCE 1 PART NO. S1-T8775C1005

74

• The temperature setting is held permanently in memory in the event of a power failure. • Powered through heating-cooling system controls. • System and Fan switches. • Manual changeover from heat to cool. • Easy installation, set up and 5-minute compressor bypass saves time and increases installer productivity. • Easily configurable by the use of DIP switches. • F or C temperature display. • Selectable heating cycle rates (1, 3, 6, 9 cph) for a variety of applications. • Cooling cycle rate is fixed at 3 cph. This is the standard compressor setting for quick installations. • Minimum off-time for compressors in the cooling mode. Protects and extends the life of the equipment. • Decorative cover plate is available to cover marks on the wall or to mount the T8775 thermostat onto an electrical box.

STAGES HEAT COOL

APPLICATION 24 VAC GAS, OIL AND ELECTRIC HEATING WITH COOLING, INCLUDING 1 HEAT/1 COOL HEAT PUMPS

1

1

STOCKED NON STOCKED

Specifications: Mounting: Front wired Changeover: Manual Color: Premier White® Power Method: Powered through heatingcooling system controls Switch Type: Electronic Accuracy (F): 0.5°C Accuracy (C): 1°F Dimensions (in.): 3-11/16” diameter x 1-7/16”D Dimensions (mm): 94 mm diameter x 37 mm D Setting Temperature Range (F): 40°F to 90°F in heating; 45°F to 99°F in cooling Setting Temperature Range (C): 4.5°C to 32°C in heating; 7°C to 37°C in cooling Electrical Ratings: 20 to 30 VAC Cycles per Hour Adj.: 1,3,6,9 Ambient Temperature Range (F): 40°F to 110°F Ambient Temperature Range (C): 4.5°C to 43.3°C Humidity Ratings (%RH): 5 to 90% RH Includes Wallplate, 4074FAB resistor, mounting screws and wall anchors.

TERMINAL DESIGNATIONS R, RC, O, B, G, Y, W

SWITCH POSITIONS FAN SYSTEM AUTO-ON

OFF-HEAT-COOL

MLP $112.74

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL DIGITAL THERMOSTATS

T7350 Commercial Programmable Thermostat For Single- or Multi-Stage Conventional/Heat Pump Systems

The T7350 controls 24 VAC commercial single zone heating, ventilating and air conditioning equipment. The T7350 consists of a thermostat and subbase. The thermostat includes the keypad and display for 7-day programming.

SOURCE 1 PART NO. S1-T7350B1002 S1-T7350H1009

APPLICATIONS CONVENTIONAL OR HEAT PUMP

The subbase includes equipment control connections. Features: • Typically used in buildings under 55,000 square feet. • For single zone rooftop units, split systems, heat pumps or hot/chilled water systems. • 7-day programming includes 2 Occupied and 2 Not Occupied periods per day • Individual heat and cool setpoints available for Occupied and Not Occupied periods. • Recovery ramp control automatically optimizes equipment start times based on building load. • Convenient overrides allow temporary setpoint changes.

MAXIMUM STAGES * HEAT COOL 2† 3 (2) **

2† 3 (4) **

• Keypad multi-level lockout available with all models • The thermostat maintains programmed times and temperatures for the life of the product. Clock and day information is retained for a minimum of 48 hours in the event of a power outage. Specifications: Electrical Power: 24 VAC, 50/60 Hz; 20–30 VAC, 50/60 Hz Operating Humidity: 5%–90% RH, noncondensing Operating Ambient Temperatures: 30°– 110°F (-1°–43°C) Display Accuracy: ±1°F (±1°C) Setpoint Ranges: Heating: 40°–90°F (4°–32°C) Cooling: 45°–99°F (7°–37°C)

FEATURES

AUXILIARY RELAY

MLP

OUTDOOR, DISCHARGE AIR CAPABILITY HUMIDITY, OCCUPANCY, OUTDOOR, DISCHARGE AIR CAPABILITY

YES

$472.39

ISOLATED NORMALLY OPEN

787.64

* All models are down-selectable; can be configured to control fewer stages than the maximum allowed. † One extra stage (of either heat or cool) can be configured using the auxiliary relay. ** Heat pump applications for this model have a maximum of 2 heat stages and 2 cool stages.

VisionPRO™ Commercial Programmable Thermostat

The TB8220 Commercial VisionPRO™ 8000 Touchscreen Programmable Thermostat is an effortless, seven-day programmable thermostat that provides universal system compatibility, precise comfort control and is easy to program. SOURCE 1 PART NO.

S1-TB8220U1003

The TB8220 provides temperature control for gas, oil, electric and heat pumps for up to 2 heat, 2 cool systems. Features: • Large, clear display with backlight shows the current and set temperature and time—even in the dark • Menu-driven programming makes setup effortless • Beautiful ergonomic design is smart and sophisticated to match your customers’ lifestyles • Touchscreen interaction • Real-time clock keeps time during power failures and automatically updates to daylight savings • “Saving Changes” notification lets you know when the schedule changes have been saved

• Change reminders let you know when to replace the batteries • Holiday Override options allow you to override the program schedule, as desired • Speedy same-schedule programming—no need to copy multiple days • Armchair programming allows you to remove the thermostat from the wall for programming Specifications: Electrical Ratings: Voltage: 20–30 VAC at 50/60 Hz; Running Current: 0.02–1.0A (Fan 0.02– 0.60A) Temperature Setting Ranges: Heating: 40°–90°F (4°–32°C) Cooling: 50°–99°F (10°–37°C) Humidity Ratings: 5%–90% RH non-condensing

DESCRIPTION

APPLICATIONS

MLP

COMMERCIAL VISIONPRO™ 8000

GAS OR ELECTRIC HEAT WITH AIR CONDITIONING WARM AIR, HOT WATER, HIGH-EFFICIENCY FURNACES, AND HEAT PUMPS HEAT ONLY HEAT ONLY WITH FAN COOL ONLY

$436.43

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

75


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL DIGITAL THERMOSTATS

C7189 Indoor Remote Temperature Sensor

SOURCE 1 PART NO. S1-C7189U1005

OPERATING TEMPERATURE RANGE

APPLICATION ®

INDOOR REMOTE TEMPERATURE SENSORS FOR USE WITH VISIONPRO

45° TO 88°F (7.2° TO 32°C)

MLP $58.77

C7089 Outdoor Sensor for TH8000 Thermostats Specifications: Display Range: –40° to 127°F (–40° to 53°C) Sensor Accuracy: ±1.5°F at 70°F (±0.84°C at 21°C) Dimensions: 2-1/4” x 3/8” with 60” leadwires (57mm x 10mm with 1524mm leadwires)

SOURCE 1 PART NO. S1-C7089U1006

76

OPERATING RELATIVE HUMIDITY

APPLICATION USED WITH TH8000 AND TH7000 THERMOSTAT FAMILIES

5% TO 95% NON-CONDENSING

STOCKED NON STOCKED

OPERATING TEMPERATURE RANGE (AMBIENT) –40° TO 120°F (–40° TO 49°C)

MLP $50.36

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

BEKO THERMOSTAT GUARDS

Designer Series LOW PROFILE STYLE Inside Dimensions BASE TYPE HEIGHT WIDTH DEPTH DUAL SOLID DUAL RING

SOURCE 1 PART NO. S1-BTGDK1 S1-BTGDK2 S1-BTG-DO S1-BTGDK S1-BTGDB

4-1/4” 4-1/8”

7-5/8” 7-1/16

2-1/8" 2-1/4"

DESCRIPTION

CTN. QTY.

MLP *

CLEAR PLASTIC (2 BASES) WITH OVAL/ROUND HOLES CLEAR PLASTIC (2 BASES) WITH OVAL/ROUND HOLES, FOR CS90 OPAQUE PLASTIC, FOR ELECTRONIC THERMOSTATS CLEAR PLASTIC (2 BASES) BRONZE PLASTIC (2 BASES)

12 12 — 12 12

$31.43 31.43 N/A 26.19 47.14

* MLP Per Each

Elite Series SOURCE 1 PART NO. S1-BTGEB S1-BTGEO S1-BTG-EK

DESCRIPTION

CTN. QTY.

MLP *

BRONZE PLASTIC (SOLID BASE) OPAQUE PLASTIC (SOLID BASE) CLEAR PLASTIC (SOLID BASE)

12 12 —

$28.29 19.32 N/A

* MLP Per Each

Classic Series MEDIUM SIZE Inside Dimensions BASE TYPE HEIGHT WIDTH DEPTH SOLID RING SOURCE 1 PART NO. S1-BTGB S1-BTGK S1-BTGO S1-BTGKM S1-BTGKWM

4-3/8” 4-5/8”

DESCRIPTION

CTN. QTY.

MLP *

BRONZE PLASTIC (2 BASES) CLEAR PLASTIC DUAL (2 BASES) OPAQUE PLASTIC (2 BASES) BEIGE METAL, SOLID BASE BEIGE METAL, RING BASE

12 12 12 12 12

$26.19 26.12 34.57 44.00 44.00

5-1/4” 5-1/4”

3" 3-1/4"

* MLP Per Each

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

77


hemrichelectric.com

info@hemrichelectric.com

BEKO THERMOSTAT GUARDS

Regal Series IDEAL FOR HORIZONTAL AND VERTICAL STANDARD SIZE WALL THERMOSTATS Inside Dimensions BASE TYPE HEIGHT WIDTH DEPTH SOLID RING

SOURCE 1 PART NO. S1-BTGRB S1-BTGRK S1-BTGRM S1-BTGRO S1-BTGRWM

6-3/8” 6-3/8”

DESCRIPTION

CTN. QTY.

MLP *

BRONZE PLASTIC (2 BASES) CLEAR PLASTIC (2 BASES) BEIGE METAL, SOLID OPAQUE PLASTIC (2 BASES) BEIGE METAL, RING

12 12 12 12 12

$26.19 20.95 44.00 25.14 44.00

3-1/2” 3-1/2”

3" 3-1/4"“

* MLP Per Each

Universal Series Plastic Inside Dimensions BASE TYPE HEIGHT WIDTH DEPTH SOLID RING

8-1/4” 8-1/8”

5-3/8” 4-5/8”

3-1/2" 3-5/8"

Metal Inside Dimensions BASE TYPE HEIGHT WIDTH DEPTH SOLID RING SOURCE 1 PART NO. S1-BTGUK2 S1-BTGUO2 S1-BTGUB2 S1-BTGUM S1-BTGUM2 S1-BTGUWM1DOWR S1-BTGUWM

DESCRIPTION CLEAR PLASTIC (2 BASES) OPAQUE PLASTIC (2 BASES) BRONZE PLASTIC (2 BASES) BEIGE METAL, SOLID WHITE METAL, COMBO BASE WHITE METAL, RING BASE WITH OVAL/ROUND DISP. HOLE, FOR 1F90 BEIGE METAL, RING

7-1/4” 6-3/4”

5-3/8” 4-1/4”

CTN. QTY.

MLP *

12 12 12 12 12

$26.29 27.25 26.19 36.67 45.33

12

47.14

12

36.67

3-1/2" 3-9/16"

* MLP Per Each

Sentinal Series THIS STRONG THERMOSTAT GUARD, CAN BE MOUNTED HORIZONTAL OR VERTICAL AND IS COMPLETELY TAMPER PROOF. Inside Dimensions BASE TYPE HEIGHT WIDTH DEPTH SOLID RING SOURCE 1 PART NO. S1-BTG54VL S1-BTG54VLW

6-1/4" 6”

4-3/4” 3-13/16”

3" 3-1/8"

DESCRIPTION

CTN. QTY.

MLP *

BEIGE METAL, SOLID BEIGE METAL, RING

12 12

$40.94 37.70

* MLP Per Each

78

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Source 1 Four-Zone Expandable Control Panels REFRIGERATION CONTROLS

Zone System, Model S1-MZS4 The S1-MZS4 can control various types of HVAC Equipment all from the same panel. The S1-MZS4 features allow the use of single stage thermostats to control up to three stage heating and two stage cooling and simple heat pump thermostats to control heat pumps. The S1MZS4 has various features that make installation and checkout very simple for all of the board’s functionality. The S1-MZS4 panel is made of sturdy ABS plastic and can be mounted to any flat surface. It is recommended that the panel be mounted to a wall or return plenum and NOT on the furSOURCE 1 PART NO. S1-MZS4 S1-MZSK

nace or plenum where it will be in contact with the hot temperatures. The panel can be located in an attic space or in an enclosed cabinet of a rooftop unit, in order for the panel to not be in direct exposure to the elements. The S1-MZS4’s basic function is zone control. On a call for heating or cooling, the panel will accept the first call from any zone. Upon accepting this call the S1-MZS4 will open the damper(s) to the zone(s) calling, close the damper(s) to those zones not calling, activate the needed HVAC controls for heating or cooling, whichever is being called and not accept any calls for the opposite mode. Once all zone thermostats are satisfied for heating and cooling, the S1-MZS4 will accept Fan calls allowing Continuous Air Circulation(CAC) in those zones where the thermostat’s Fan Switch is set to ON. These zone dampers will be Open while the dampers to the zones where the Fan Switch is set to AUTO will be CLOSED. When all zone thermostats are satisfied for both Heating and Cooling, and all Fan switches are set to AUTO position, the HVAC unit will be off and all zone dampers will return to a norDESCRIPTION ZONING CONTROL PANEL ZONING CONTROL PANEL KIT

mally open position. Once a zone calls for heating, cooling or fan, the dampers to the calling zones remain open and the dampers to the zones not calling will close. The S1-MZS4 is factory set for conventional fossil fuel (oil or gas) single and up to three stage heating and two stage cooling. The panel only needs to be configured when using with an conventional electric furnace or hydro-air system in order to bring the fan on with a call for heat, or when using with a heat pump equipment and thermostats. Features: • Color coded push-in wiring blocks • LED indicator lights for system operation • Individual zone indicating lights • Single stage, two stage, and heat pump compatible • Expandable to any number of Zones • Uses any four-wire thermostat • Leaving air sensor for capacity protection • Staging by time or by number of zones calling • Intelligent changeover timing

ZONES STAGES VOLTAGE 4

2H/2C

24

MLP $486.43 519.75

Note: S1-MZSK includes S1-MZS4 plus S1-ZMS leaving air sensor and 24V transformer

Source 1 Two-Zone Add-On Module

A two-zone expansion panel used to add zones onto an S1-MZS4 Zone Control Panel. The S1-MZA2 requires its own separate 24 Volt AC transformer. The panel also includes a modular jack cord which connects the S1MZA2 with the main S1-MZS4 panel. The S1MZA2 is NOT a stand alone zoning panel and is used only as an expansion panel for one or two additional zones when using the S1-MZS4 as the main zoning panel.

SOURCE 1 PART NO. S1-MZA2

When either zone thermostat calls, for either Cooling or Heating, the S1-MZA2 panel will take the call and look at the S1-MZS4 status. If there are no other calls open the damper to that zone, if not already open, close the dampers to the zones that are not calling for the same mode and activate the appropriate heating or cooling on the HVAC Unit. If other zones call for the same mode, the S1-MZS4 panel will allow these calls and open these zone dampers until all zones are satisfied, unless there are calls from other zones for the opposite mode. When there are opposing calls, the S1-MZS4 panel has a design of intelligent changeover that can allow those zones to satisfy or eventually switch over to the opposite mode if there are calls for the opposite mode, based on the number of those zones calling. The S1-MZS4 panel also can control two-stage and heat pump systems using single stage thermostats. This substantially reduces the overall cost of the zone system by using less expensive conventional single stage thermostats. The S1-MZS4 has a built-in timer that once a call is made the timer begins and if the demand is not satisfied within that period of DESCRIPTION ADD-ON ZONING MODULE

time the second stage will be activated until the call is satisfied. The second stage can also be activated based on the number of zones calling in place of the timer. The only time a heat pump thermostat is necessary is when it is desired to control the Emergency Heat from each zone’s thermostat. Features: • Two Zone Expansion Panel • Modular Jacks for Easy Add-On Connection • Color-Coded Screwless Terminal Blocks • Individual Zone Indicating Lights • Indicator LEDs for System Operation • Expand Systems up to 10 Zones Panel Specifications Construction: ABS plastic Number of Zones: 2 Expansion Dimensions: 7-5/8”x 7-1/4” x 1-3/8” Voltage: 24 VAC, 50/60 Hz Temperature Rating: 0°F to 120°F Operating, –20°F to 140°F Storage Humidity: 5% to 95% Non-Condensing Connection: Screwless push-in terminal blocks

ZONES STAGES VOLTAGE 2

MLP $195.00

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

79


hemrichelectric.com

info@hemrichelectric.com

Source 1 Three-Zone Single Stage Control Panels

The S1-MMZ3 Zoning Panel is a 2 and 3 zone, single stage heating and cooling control panel. This electronic panel provides the simplest zoning functions and works with all standard heating and cooling thermostats. The S1-MMZ3 panels are designed to use a minimum of wires to make zoning simple and affordable. Each zone uses a standard 4 wire (Y-G-R-W) thermostat. The panels also feature a separate C-common terminal for 24 Volt powered thermostats. All terminal blocks are color coded for each wire and have push-in connections making wiring even simpler with no need for a small screwdriver, as with all other zoning panels. The state of the art surface mount techSOURCE 1 PART NO. S1-MMZ3 S1-MMZK

nology for all electronic components makes for a highly reliable control panel. The zoning operation is very simple and basic. Any zone can call for heating or cooling. Once the first zone calls, the panel will only accept other calls for the same mode, either heating or cooling. Once all of these calls are satisfied, or a maximum of 20 minutes elapses, the panel will cut off the HVAC Unit, purge the conditioned air in the duct system and then look for opposite calls. If opposite calls exist the panel will switch over and supply that mode for the zones calling. When all zones are satisfied for both heating and cooling, the panel will then accept Fan calls from each thermostat’s Fan switch. This will provide for zoned air circulation. Zones where the thermostat’s fan switch is ON, will have their dampers open and the fan circulating air continuously. Zones where the Fan switch is in AUTO, will close their damper until a call is needed for heating or cooling. If all thermostat Fan switches are in AUTO, the fan will be off and all dampers return to a normally open position awaiting a call. The S1-MMZ3 panels are compatible with any single stage heating and cooling system and is DESCRIPTION ZONING CONTROL PANEL ZONING CONTROL PANEL KIT

affordable enough that it can also be used to zone heating only or cooling only systems as well. It can control any Gas-Oil or Electric Heating Furnace, with or without Cooling and also zone Hydro-Air Systems using a hot water coil in a cooling air handler. Features: • Economy two and three zone control panel • LED indicator lights for system operation • Individual zone indicating lights • Heating only or cooling only • Single stage heating and cooling Panel Specifications: Construction: ABS plastic Number of Zones: 2 and 3 Zones, Single Stage Heating and Cooling Dimensions: 7-5/8” x 7-1/4” x 1-3/8” Voltage: 24 VAC, 50/60 Hz Temperature Rating: 0°F to 120°F Operating, –20°F to 140°F Storage Humidity: 5% to 95% Non-Condensing Connection: Screwless push-in terminal blocks

ZONES STAGES VOLTAGE 3

SINGLE

24

MLP $214.29 283.32

Note: S1-MMZK includes S1-MMZ3 plus S1-ZMS leaving air sensor and 24V transformer

Source 1 Three-Zone Multi-Stage Control Panels

The S1-MMH3 Panel can control up to 3 zones and is capable of controlling single stage and two stage heating and cooling, as well as up to three stage heating, multi-speed and dual fuel heat pumps. This multi-function board uses any 4-wire thermostat. Two stage and heat pump thermostats are NOT required, however Heat Pump thermostats can be used to remotely control the Emergency Heat. The S1-MMH3 provides the basic function of zoning by being the central control panel where all zone thermostats, zone damper motors and HVAC Equipment wire. A separate 24 Volt, 40VA Transformer powers the panel and a separate remote Leaving Air Sensor is wired to the panel to provide protection and capacity control of the HVAC Equipment. When using dual fuel SOURCE 1 PART NO. S1-MMH3 S1-MMHK

heat pumps an outdoor sensor is also wired to control the changeover between heat pump and furnace mode. When any zone thermostat makes a call, for either Cooling or Heating, the S1-MMH3 panel will take the first call, open the damper to that zone, if not already open, close the dampers to the zones that are not calling for the same mode and activate the appropriate heating or cooling on the HVAC Unit. If other zones call for the same mode, the S1MMH3 panel will allow these calls and open these zone dampers until all zones are satisfied. When there are opposing calls the S1MMH3 panel has an exclusive design of intelligent changeover that can allow those zones to satisfy or eventually switch over to the opposite mode. The S1-MMH3 panel can control conventional two stage heating, two stage cooling and heat pump systems using single stage thermostats. This substantially reduces the overall cost of the zone system by using less expensive conventional single stage thermostats. The S1MMH3 has a built-in timer that once a call is made the timer begins and if the demand is not satisfied within that period of time the second and eventually third stage will be activated until the call is satisfied. The panel also has simple Light Emitting Diodes (LED) indicator to easily monitor the system status. Two LEDs can be DESCRIPTION ZONING CONTROL PANEL ZONING CONTROL PANEL KIT

seen through the panel's front cover. These monitor the basic system operation. By removing the cover, each zone has an indicator light to show when the zone damper is open or the zone is calling. Features: • Color-Coded Push-In Wiring Blocks • Uses Any Four Wire Thermostat • Three Stage Heating, Two Stage Cooling & Heat Pumps • Two and Three Zone Panel • Leaving Air Sensor for Capacity Protection • Intelligent Changeover Timing • Indicator Lights for System Operation Panel Specifications: Construction: ABS plastic Number of Zones: 2 and 3 Zones, Single Stage Heating and Cooling Dimensions: 7-5/8" x 7-1/4" x 1-3/8" Voltage: 24 VAC, 50/60 Hz Temperature Rating: 0°F to 120°F Operating, –20°F to 140°F Storage Humidity: 5% to 95% Non-Condensing Connection: Screwless push-in terminal blocks

ZONES STAGES VOLTAGE 3

2H/1C

24

MLP $267.86 322.61

Note: S1-MMHK includes S1-MMH3 plus S1-ZMS leaving air sensor and 24V transformer

80

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Source 1 Zoning Accessories

Static Pressure Switch, Model S1-SPS The Static Pressure Switch is used to sense the supply air duct’s static pressure and control the modulating by-pass damper (Models S1ZDM or S1-RDM) in order to maintain the duct system air pressure. When used on a zone

control system, the supply air static pressure increases as various zone dampers close down. The increase in static pressure can become noisy and reduce the volume of air through the HVAC Unit, if the static overcomes the rating of the blower. The S1-SPS controls this by sensing the increased static and signaling the modulating by-pass damper to open. As the by-pass damper opens to relieve the excess static, the air pressure in the duct decreases. The damper responds to the control signal of the SPS. When the static pressure rises above 0.3”W.C., the S1-SPS will power the motorized by-pass damper open. As the by-pass damper opens the duct static should decrease below this higher setting of 0.3” and as it does the damper stops. If other zone dampers open and the static continues to fall below the lower setting of 0.2” W.C., the by-pass damper will close. The two setpoints of 0.2” and 0.3” and

SOURCE 1 PART NO. S1-SPC S1-SPS S1-ZMS

the SPST contacts for each, provide the control for the by-pass damper to truly modulate to prevent excessive static pressure in the system. By-Pass Control Operation Above 0.3” W.C. - Damper Opens Between 0.2”W.C. and 0.3”W.C. - Damper Stops Below 0.2” W.C. - Damper Closes The S1-SPS design incorporates two pressure sensitive diaphragms and two single pole single throw snap action electrical switches. Electrical Ratings: SPST Snap Acting Electronic Switches 28VA Pilot Duty @ 24VAC 125VA @ 125VAC SPST Electrical Load 3 A Resistive @ 120VAC

DESCRIPTION

MLP

STATIC PRESSURE ZONING CONTROL STATIC PRESSURE ZONING SWITCH DISCHARGE AIR ZONING SENSOR

$357.86 109.29 54.95

Source 1 Modulating Round Zoning Dampers

The S1-RDM can be used for zone control or as the motorized damper for by-pass air when controlled by the Static Pressure Switch, Model S1-SPS. It is designed to also handle high pressure air conditioning systems up to 4”S.P.

The motor actuator delivers up to 18 in/lbs of torque that powers the S1-RDM open and closed. This powerful motor allows the damper to handle higher static pressures and can be modulates using the SPS Static Pressure Switch or similar type control. Features: • 3-wire, power open and close • LED damper position indicators • Neoprene gasket seal • 24 VAC Damper Specifications: Construction: 22 Ga. Galvanized Steel Linkage: Direct Drive Motor Voltage: 24 VAC, 50/60 Hz, 6.5 Watts, 7VA Torque: 35 in-lbs.

Temperature Rating: 0°F to 120°F Operating, –20°F to 140°F Storage Humidity: 5% to 95% Non-Condensing Damper Timing: Nominal 30 Sec. Powered Connection: Screw Terminals Duct Pressure: Maximum 4.0” W.C. SOURCE 1 PART NO. S1-RDM05 S1-RDM06 S1-RDM07 S1-RDM08 S1-RDM09 S1-RDM10 S1-RDM12 S1-RDM14 S1-RDM16 S1-RDM18

SIZE (IN.)

MLP

5 6 7 8 9 10 12 14 16 18

$173.57 193.32 194.75 197.52 200.80 203.28 212.73 220.71 232.02 246.55

Source 1 Retro-Round Zoning Dampers A 24 Volt AC, power open, power closed damper. The damper is simply inserted into rigid metal branch ducts. The single blade is powered open and close to control the flow of air to each outlet. The S1-RRM damper blade has a wide wiper seal to seal against the inside of the ducts. The S1-RDM can be used for zone control or as the motorized damper for by-pass air when controlled by

the Static Pressure Switch, Model S1-SPS. It is designed to also handle high pressure air conditioning systems up to 4”S.P. The simple 3 wire motor has a Red motor release button that allows the damper blade to be manually rotated without harm to the motor. It also has LED position indicators that illuminate GREEN when Open and RED when Closed. The motor actuator delivers up to 18 in/lbs of torque that powers the S1-RRM open and closed. This powerful motor allows the damper to handle higher than normal static pressure, up to 3”W.C. Multiple dampers can be wired in parallel. Up to 12 dampers per 40VA transformer. When more than 12 dampers are required use a larger VA transformer. Each motor requires 3VA.

Features: • Plug-and-play wiring • Power open and close • LED damper position indicators • Rubber gasket seal • 24 VAC SOURCE 1 PART NO. S1-RRM04 S1-RRM05 S1-RRM06 S1-RRM07 S1-RRM08

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

SIZE (IN.)

MLP

4 5 6 7 8

$174.71 174.71 178.91 178.91 179.83

81


hemrichelectric.com

info@hemrichelectric.com

Source 1 Rectangular Zoning Dampers Features: • 3-wire, power open and close • LED damper position indicators • Parallel aluminum blades • 24 VAC

S1-ZDMB1 SOURCE 1 PART NO. BOTTOM MOUNT S1-ZDMB0808 S1-ZDMB0810 S1-ZDMB0812 S1-ZDMB0814 S1-ZDMB0816 S1-ZDMB0818 S1-ZDMB0820 S1-ZDMB0822 S1-ZDMB0824 S1-ZDMB0826 S1-ZDMB0828 S1-ZDMB0830 S1-ZDMB0832 S1-ZDMB0834 S1-ZDMB0836 S1-ZDMB1010 S1-ZDMB1012 S1-ZDMB1014 S1-ZDMB1016 S1-ZDMB1018 S1-ZDMB1020 S1-ZDMB1022 S1-ZDMB1024 S1-ZDMB1026 S1-ZDMB1028 S1-ZDMB1030 S1-ZDMB1032 S1-ZDMB1034 S1-ZDMB1036 S1-ZDMB1212 S1-ZDMB1214 S1-ZDMB1216 S1-ZDMB1218 S1-ZDMB1220 S1-ZDMB1222 S1-ZDMB1224 S1-ZDMB1226 S1-ZDMB1228 S1-ZDMB1230 S1-ZDMB1232 S1-ZDMB1234 S1-ZDMB1236 S1-ZDMB1414 S1-ZDMB1416 S1-ZDMB1418 S1-ZDMB1420 S1-ZDMB1422 S1-ZDMB1424 S1-ZDMB1426 S1-ZDMB1428 S1-ZDMB1430 S1-ZDMB1432 S1-ZDMB1434 S1-ZDMB1436 S1-ZDMB1616 S1-ZDMB1618 S1-ZDMB1620 S1-ZDMB1622 S1-ZDMB1624 S1-ZDMB1626 S1-ZDMB1628 S1-ZDMB1630 S1-ZDMB1632 S1-ZDMB1634 S1-ZDMB1636 S1-ZDMB1818 S1-ZDMB1820

82

S1-ZDMS1610

S1-ZDMB2 SIZE (IN.) 8X8 8X10 8X12 8X14 8X16 8X18 8X20 8X22 8X24 8X26 8X28 8X30 8X32 8X34 8X36 10X10 10X12 10X14 10X16 10X18 10X20 10X22 10X24 10X26 10X28 10X30 10X32 10X34 10X36 12X12 12X14 12X16 12X18 12X20 12X22 12X24 12X26 12X28 12X30 12X32 12X34 12X36 14X14 14X16 14X18 14X20 14X22 14X24 14X26 14X28 14X30 14X32 14X34 14X36 16X16 16X18 16X20 16X22 16X24 16X26 16X28 16X30 16X32 16X34 16X36 18X18 18X20

MLP $257.76 262.19 266.71 271.81 276.52 281.05 287.10 290.81 296.14 290.76 295.29 314.76 304.52 309.10 313.62 279.95 286.76 292.19 298.29 303.52 308.95 313.24 318.67 324.10 337.00 338.43 362.95 375.29 393.14 299.76 306.14 312.48 320.24 326.57 332.19 335.81 342.19 343.43 346.43 379.76 388.52 406.38 312.00 318.38 324.71 332.81 338.33 346.14 352.95 359.62 365.90 368.14 374.48 384.81 336.00 338.29 349.71 361.14 379.43 397.71 416.00 427.43 436.57 445.71 457.14 342.86 361.14

SOURCE 1 PART NO.

SIZE (IN.)

MLP

S1-ZDMB1822 S1-ZDMB1824 S1-ZDMB1826 S1-ZDMB1828 S1-ZDMB1830 S1-ZDMB1832 S1-ZDMB1834 S1-ZDMB1836 S1-ZDMB2020 S1-ZDMB2022 S1-ZDMB2024 S1-ZDMB2026 S1-ZDMB2028 S1-ZDMB2030 S1-ZDMB2032 S1-ZDMB2034 S1-ZDMB2036 S1-ZDMB2222 S1-ZDMB2224 S1-ZDMB2226 S1-ZDMB2228 S1-ZDMB2230 S1-ZDMB2232 S1-ZDMB2234 S1-ZDMB2236 S1-ZDMB2424 S1-ZDMB2426 S1-ZDMB2428 S1-ZDMB2430 S1-ZDMB2432 S1-ZDMB2434 S1-ZDMB2436

18X22 18X24 18X26 18X28 18X30 18X32 18X34 18X36 20X20 20X22 20X24 20X26 20X28 20X30 20X32 20X34 20X36 22X22 22X24 22X26 22X28 22X30 22X32 22X34 22X36 24X24 24X26 24X28 24X30 24X32 24X34 24X36

384.00 393.14 416.00 426.67 457.14 466.29 480.00 491.43 374.86 404.57 416.00 438.86 443.43 468.57 480.00 493.71 507.43 434.29 441.14 459.43 464.00 489.14 507.43 518.86 534.86 468.57 480.00 484.57 514.29 528.00 541.71 557.24

SIDE MOUNT S1-ZDMS0808 S1-ZDMS1008 S1-ZDMS1010 S1-ZDMS1208 S1-ZDMS1210 S1-ZDMS1212 S1-ZDMS1408 S1-ZDMS1410 S1-ZDMS1412 S1-ZDMS1414 S1-ZDMS1608 S1-ZDMS1610 S1-ZDMS1612 S1-ZDMS1614 S1-ZDMS1616 S1-ZDMS1808 S1-ZDMS1810 S1-ZDMS1812 S1-ZDMS1814 S1-ZDMS1816 S1-ZDMS1818 S1-ZDMS2008 S1-ZDMS2010 S1-ZDMS2012 S1-ZDMS2014 S1-ZDMS2016 S1-ZDMS2018 S1-ZDMS2020 S1-ZDMS2208 S1-ZDMS2210 S1-ZDMS2212 S1-ZDMS2214 S1-ZDMS2216 S1-ZDMS2218 S1-ZDMS2220

8X8 10X8 10X10 12X8 12X10 12X12 14X8 14X10 14X12 14X14 16X8 16X10 16X12 16X14 16X16 18X8 18X10 18X12 18X14 18X16 18X18 20X8 20X10 20X12 20X14 20X16 20X18 20X20 22X8 22X10 22X12 22X14 22X16 22X18 22X20

$257.76 262.19 279.95 266.71 286.76 299.76 271.81 292.19 306.14 312.00 276.52 298.29 312.48 318.38 336.00 281.05 303.52 320.24 324.71 338.29 342.86 287.10 308.95 326.57 332.81 349.71 361.14 374.86 290.81 313.24 332.19 338.33 361.14 384.00 404.57

STOCKED NON STOCKED

SOURCE 1 PART NO. S1-ZDMS2222 S1-ZDMS2408 S1-ZDMS2410 S1-ZDMS2412 S1-ZDMS2414 S1-ZDMS2416 S1-ZDMS2418 S1-ZDMS2420 S1-ZDMS2422 S1-ZDMS2424 S1-ZDMS2608 S1-ZDMS2610 S1-ZDMS2612 S1-ZDMS2614 S1-ZDMS2616 S1-ZDMS2618 S1-ZDMS2620 S1-ZDMS2622 S1-ZDMS2624 S1-ZDMS2808 S1-ZDMS2810 S1-ZDMS2812 S1-ZDMS2814 S1-ZDMS2816 S1-ZDMS2818 S1-ZDMS2820 S1-ZDMS2822 S1-ZDMS2824 S1-ZDMS3008 S1-ZDMS3010 S1-ZDMS3012 S1-ZDMS3014 S1-ZDMS3016 S1-ZDMS3018 S1-ZDMS3020 S1-ZDMS3022 S1-ZDMS3024 S1-ZDMS3208 S1-ZDMS3210 S1-ZDMS3212 S1-ZDMS3214 S1-ZDMS3216 S1-ZDMS3218 S1-ZDMS3220 S1-ZDMS3222 S1-ZDMS3224 S1-ZDMS3408 S1-ZDMS3410 S1-ZDMS3412 S1-ZDMS3414 S1-ZDMS3416 S1-ZDMS3418 S1-ZDMS3420 S1-ZDMS3422 S1-ZDMS3424 S1-ZDMS3608 S1-ZDMS3610 S1-ZDMS3612 S1-ZDMS3614 S1-ZDMS3616 S1-ZDMS3618 S1-ZDMS3620 S1-ZDMS3622 S1-ZDMS3624

SIZE (IN.)

MLP

22X22 24X8 24X10 24X12 24X14 24X16 24X18 24X20 24X22 24X24 26X8 26X10 26X12 26X14 26X16 26X18 26X20 26X22 26X24 28X8 28X10 28X12 28X14 28X16 28X18 28X20 28X22 28X24 30X8 30X10 30X12 30X14 30X16 30X18 30X20 30X22 30X24 32X8 32X10 32X12 32X14 32X16 32X18 32X20 32X22 32X24 34X8 34X10 34X12 34X14 34X16 34X18 34X20 34X22 34X24 36X8 36X10 36X12 36X14 36X16 36X18 36X20 36X22 36X24

434.29 296.14 318.67 335.81 346.14 379.43 393.14 416.00 441.14 468.57 290.76 324.10 342.19 352.95 397.71 416.00 438.86 459.43 480.00 295.29 337.00 343.43 359.62 416.00 426.67 443.43 464.00 484.57 314.76 338.43 346.43 365.90 427.43 457.14 468.57 489.14 514.29 304.52 362.95 379.76 368.14 436.57 466.29 480.00 507.43 528.00 309.10 375.29 388.52 374.48 445.71 480.00 493.71 518.86 541.71 313.62 393.14 406.38 384.81 457.14 491.43 507.43 534.86 557.24

Note: S1-ZDMB and S1-ZDMS dampers can be used as modulating powered bypass dampers when applied with S1-SPS static pressure zoning switch.

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Source 1 Barometric By-Pass Dampers

S1-SPRD Rectangular

The Static Pressure Regulating Dampers, Model SPRD, are barometric relief dampers used to by-pass excess air pressure on zoned systems. The SPRDs automatically respond to the air pressure in duct as the various zone dampers open and close. As zone dampers close off air to a number of zones, the supply air pressure in the duct system will increase. This increase in air pressure can increase the noise level and reduce the flow of conditioned air through the HVAC Unit. Using the SPRD solves this by automatically compensating for the excess air pressure by opening on the increased pressure and relieving the excess air. The SPRD helps maintain a constant air pressure in the duct system. This reduces noise that is caused by high air pressures and velocities, as well as maintains a constant volume of air (CFM) through the duct system. Maintaining a constant volume of air through the HVAC System keeps the efficiency of the system at its maximum. The SPRD is available in square/rectangular and round sizes. The following chart lists the available sizes of SPRDs and their recommended CFM capacities.

S1-SPRD Round

SQUARE AND RECTANGULAR SIZES SIZE CFM SIZE CFM 12"X8” 12"X10” 12"X12” SIZE (DIAMETER) 7” 8” 9” 10”

800 1000 1400

20"X8: 20"X10: 20"X12”

ROUND SIZES SIZE CFM (DIAMETER) 200 400 600 750

12” 14” 16” 18”

1600 2000 2400

CFM 1000 1600 2400 3000

Calculating By-Pass Air Requirements: Determining the need for by-pass air and the size of the SPRD required is very simple. It can be very simply calculated by knowing the total CFM capacity of the HVAC unit (TCFM) and subtracting the CFM capacity of the smallest zone (SCFM) will equal the CFM of air required to be by-passed (BCFM). TCFM – SCFM = BCFM (Total CFM minus Smallest Zone CFM equals By-Pass CFM) Once the by-pass amount of air is known, use the chart below to select an appropriately sized by-pass damper. It is always recommended to have a larger size by-pass than having one that is too small. It is much easier to reduce bypass air through the damper or close it off than

having to increase the size of the by-pass duct and/or damper. Location: Selecting a location to place the SPRD is very important for overall system operation. Ideally the best place for the SPRD is as far away from the air handler as possible and before any zone dampers. In an extended plenum application where zones come of the side of the main trunk, the end of the extended plenum is the ideal situation. Square and Rectangular SPRD Damper Specifications: Construction: 22 Gauge Zinc Plated Steel Dimensions: 12”x8”, 12”x10”, 12”x12”, 20”x8”, 20”x10”, 20”x12” Temperature Rating: 0°F to 180°F Operating, –20°F to 140°F Storage Humidity: 5% to 95% Non-Condensing Static Pressure: Maximum 0.5” W.C. Round SPRD Damper Specifications: Construction: 22 Gauge Galvanized Steel Dimensions: 5”, 6”, 7”, 8”, 9”, 10”,12”, 14”, 16”, 18”, 20” Diameters Temperature Rating: 0°F to 180°F Operating, –20°F to 140°F Storage Humidity: 5% to 95% Non-Condensing Static Pressure: Maximum 0.5” W.C.

SOURCE 1 RECTANGULAR BAROMETRIC BYPASS DAMPERS SOURCE 1 SIZE PART NO. (IN.) MLP S1-SPRD1208 S1-SPRD1210 S1-SPRD1212 S1-SPRD2008 S1-SPRD2010 S1-SPRD2012

12X8 12X10 12X12 20X8 20X10 20X12

$107.19 115.41 117.45 112.50 121.17 122.45

SOURCE 1 ROUND BAROMETRIC BYPASS DAMPERS DIAMETER SOURCE 1 SIZE PART NO. (IN.) MLP S1-SPRD08 S1-SPRD09 S1-SPRD10 S1-SPRD12 S1-SPRD14 S1-SPRD16 S1-SPRD18 S1-SPRD20

8 9 10 12 14 16 18 20

$100.71 102.86 105.00 109.90 121.07 133.88 153.06 171.56

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

83


hemrichelectric.com

info@hemrichelectric.com

Source 1 Liquid Line Filter-Driers Features: • High moisture and acid capacity • Maximum filtration capacity • Exceptional compatibility with new polyester oils • Compatible with all existing and new refrigerants and blends including 134a, 401A/B, SOURCE 1 PART NO. S1-LFD053S S1-LFD083S S1-LFD163S S1-LFD164S

TYPE

LIQUID

402A/B, 404A, 407A/B/C, 410A, 502, and 507A • Spring-loaded, molecular sieve and activated alumina • Solid copper sweat fittings • Corrosion-resistant powder coated exterior surpasses 500-hr ASTM salt spray test

ODF

CU IN.

MLP

3/8

5 8

$15.18 17.54 18.39 18.86

16

1/2

Source 1 Bi-Flow Filter-Driers Features: • Specifically designed for heat pump or reverse cycle application • External check valves are not required since they are incorporated within the filter drier shell • The core design filters out contaminant particles down to 25 microns SOURCE 1 PART NO. S1-BFD083S S1-BFD163S

84

TYPE BI-FLOW

• 100% copper sweat fittings • Dessicant core provides three times the filtration as the standard bi-flow • Core is cushioned in fiber gaskets to protect core and to insure trouble-free performance • Corrosion-resistant powder coated exterior surpasses 500-hr ASTM salt spray test

ODF

CU IN.

MLP

3/8

8 16

$28.68 34.39

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

DRIERS

EK/EKP Extra-Klean Liquid Line Filter-Drier

Application: • Emerson Climate Technologies’ premium compacted bead filter-drier with a finer 20 micron final outlet pad for maximum filtration. • Premium Universal replacement liquid line filter-drier for CFC, HCFC and HFC refrigerants including R-410A.

Features: • Filtration first for more effective use of surface area of desiccant. • High moisture and acid removal. • Solid copper fittings. • Corrosion resistant epoxy powder paint finish. • Copeland approved for POE Oils. Specifications: Desiccant blend—75% molecular sieve and 25% activated alumina Filtration: 20 microns Maximum working pressure: —Sizes: 03–16, 680 psig —30–75, 500 psig

CUL/UL file number: SA 3124 CSA file number: LR 100624, LR 32462 EKP is marketed in Canada and Australia.

Nomenclature Example: EK-083S EK

08

3

S

S = ODF UNIT SIZE CONNECTION SIZE DRIER SERIES CONNECTIONS (IN CU. IN.) (IN 1/8”) (OMIT FOR SAE) SOURCE 1 PART NO. S1-060009 S1-060012 S1-063208 S1-060011 S1-060014 S1-047601 S1-047602 S1-047604 S1-047605 S1-047606 S1-047607 S1-047608 S1-047610 S1-047611 S1-047613 S1-047614 S1-047615 S1-047616 S1-047617 S1-047618 S1-048210 S1-048211 S1-048212 S1-048213 S1-048214 S1-048215 S1-048217 S1-048220 S1-048221 S1-048223 S1-048224 S1-048228

VENDOR TYPE NO. EK-032 EK-032S EK-032SV CAP EK-032FM EK-033S EK-052 EK-052S EK-053S EK-082 EK-082S EK-083 EK-083S EK-084S EK-162 EK-163 EK-163S EK-164 EK-164S EK-165 EK165S EK-303 EK-303S EK-304 EK-304S EK-305 EK-305S EK-307S EK-414 EK-414S EK-415S EK-417S EK-757S

A

DIMENSIONS (IN INCHES) B D E

4-3/8 3-7/8

— 3-1/8

— 3/8

3-1/2 4-1/16 4-13/16 4-7/16 4-1/2 5-5/8 5-1/4 5-15/16 5-5/16 5-3/8 6-9/16 6-7/8 6-1/4 7-1/16 6-5/16 7-12 6-9/16 9-5/8 9 9-7/8 9-1/8 10-5/16 9-5/16 9-7/8 10 9-1/4 9-7/16 10 15-7/16

— 3-3/16 — 3-11/16 3-5/8 — 4-1/2 — 4-7/16 4-3/8 — — 5-7/16 — 5-5/16 — 5-5/16 — 8-1/8 — 8-1/8 — 8-1/16 8-3/8 — 8-1/4 8-3/16 8-1/2 13-15/16

— 7/16 — 3/8 7/16 — 3/8 — 7/16 1/2 — — 7/16 — 1/2 — 5/8 — 7/16 — 1/2 — 5/8 3/4 — 1/2 5/8 3/4 3/4

F*

SHIP WT. (LBS.)

2-9/16

1-5/8

1/2

3

2-5/8

7/8

3-13/16

2-5/8

1-1/4

4-3/4

2-5/8

1-1/2

7-1/2

3-1/16

3-3/4

13-1/16

3-11/16

7-1/2

MLP $ 18.02 18.10 29.09 18.10 19.47 22.78 22.70 22.78 28.38 28.21 28.34 28.73 29.53 35.44 36.27 36.79 39.06 39.43 41.08 42.14 64.89 64.66 64.89 64.66 63.40 80.29 70.64 92.05 92.47 92.93 92.47 142.80

* Does not include weld bead

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

85


hemrichelectric.com

info@hemrichelectric.com

DRIERS

ADK Block Style Liquid Line Filter-Drier Application: Economy solid core liquid line filter-drier ideal for use with CFC and HCFC refrigerants. Features: • Solid copper fittings. • Shock resistant steel shell construction. • High moisture and acid removal capacity. • Corrosion resistant epoxy power paint finish. Specifications: Desiccant Blend: Blended for High Water Capacity Filtration: 40 microns Maximum working pressure: —Sizes: 03–16, 680 psig —Sizes: 30–75, 500 psig

CUL/UL file number: SA 3124

Nomenclature Example: ADK 083S ADK SERIES

SOURCE 1 PART NO. S1-060127 S1-060129 S1-060130 S1-060132 S1-060134 S1-059839 S1-060795 S1-059840 S1-059841 S1-060173 S1-060174 S1-060184

08

3

S

S = ODF UNIT SIZE CONNECTION SIZE CONNECTION (IN CU. IN.) (IN 1/8”) (OMIT FOR SAE) VENDOR TYPE NO.

CONNECTION SIZE (IN INCHES)

A

B

D

E

F*

SHIP WT. (LBS.)

ADK-053 ADK-082 ADK-082S ADK-083S ADK-084S ADK-163 ADK-163S ADK-164 ADK-164S ADK-304 ADK-305 ADK-415

3/8 SAE 1/4 SAE 1/4 ODF 3/8 ODF 1/2 ODF 3/8 SAE 3/8 ODF 1/2 SAE 1/2 ODF 1/2 SAE 5/8 SAE 5/8 SAE

5-1/8 5-5/8 5-1/4 5-5/16 5-3/8 6-3/4 6-1/8 6-15/16 6-3/16 9-7/8 10-5/16 10-7/16

— — 4-1/2 4-7/16 4-3/8 — 5-1/4 — 5-3/16 — — —

— — 3/8 7/16 1/2 — 7/16 — 1/2 — — —

3

2-5/8

3/4

3-13/16

2-5/8

1-1/4

4-5/8

2-5/8

2

DIMENSIONS (IN INCHES)

7-1/2

3-1/16

3-3/4

7-5/8

3-11/16

4-3/4

MLP $20.24 25.10 28.77 25.44 27.97 32.66 32.66 35.17 35.89 56.51 57.35 81.68

* Does not include weld bead

86

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

DRIERS

BFK/EBF Liquid Line Bi-Directional Heat Pump

Application: • Bi-directional liquid line filter-drier for heat pump applications. • For use with CFC, HCFC, HFC refrigerants. Features: • 16 cubic inches in a 2-1/2” diameter shell on the EBF model; the BFK model is full-sized.

• Internal check valves allow flow and filtration in either direction. External check valves eliminated. • High moisture and acid removal. • Corrosion resistant epoxy powder paint finish. • Copeland approved for POE oils. Specifications: Desiccant blend—75% molecular sieve and 25% activated alumina (Bead) Filtration: 40 microns Maximum working pressure: —Sizes: 05–16, 680 psig —Sizes: 30, 500 psig CUL/UL file number: SA 3124

Nomenclature Example: BFK 165S BFK

16

5

S

S = ODF UNIT SIZE CONNECTION SIZE SERIES CONNECTIONS (IN CU. IN.) (IN 1/8”) (OMIT FOR SAE) SOURCE 1 PART NO. S1-062425 S1-062255 S1-043323 S1-043327 S1-043330 S1-043333 S1-064412 S1-043335 S1-043337 S1-064414 S1-043734 S1-063077 S1-063081 S1-063083

VENDOR TYPE NO.

CONNECTION SIZE & STYLE

A

BFK-052S BFK-053S BFK-083S BFK-084S BFK-163 BFK-163S EBF-163S BFK-164 BFK-164S EBF-164S BFK-165S BFK-303S BFK-305S BFK-306S

1/4 ODF 3/8 ODF 3/8 ODF 1/2 ODF 3/8 SAE 3/8 ODF 3/8 ODF 1/2 SAE 1/2 ODF 1/2 ODF 5/8 ODF 3/8 ODF 5/8 ODF 3/4 ODF

4.44 4.48 5.29 5.38 6.74 6.08 6-1/8 6.96 6.17 6-3/16 6.39 8.97 9.31 9.72

DIMENSIONS (IN INCHES) B C D 3.00 3.00 3.82 3.82 4.61 4.61 4-5/8 4.61 4.61 4-5/8 4.61 7.50 7.50 7.50

3.69 3.67 4.48 4.38 5.28 5-1/4 5.17 5-3/16 5.14 8.17 8.18 8.59

E

2.62 2.62 2.62 2.62 2-5/8 2-5/8 2-5/8 2-5/8 3.15 3.15 3.15 3.15 3.15 3.15

.38 .40 .40 .50 7/16 .40 7/16 .50 1/2 .63 .40 .63 .63

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

SHIP WT. (LBS.)

1

2

3.75

MLP $ 41.19 43.89 51.72 52.03 74.97 74.97 61.27 76.20 76.20 61.00 76.86 96.04 101.27 122.98

87


hemrichelectric.com

info@hemrichelectric.com

DRIERS

BOK-HH Liquid Line Burnout Filter-Drier Features: • Designed for maximum effectiveness in the clean-up of systems following a severe burnout. • Corrosion resistant epoxy powder paint finish. • Charcoal blend for soluble contaminant and wax removal. • Solid copper fittings. Specifications: Filtration: 40 microns Maximum working pressure: —08–16, 680 psig —30–41, 500 psig CUL/UL file number: SA 3142

Application: • Emerson Climate Technologies’ BOK-HH incorporates on HH blended solid core for the effective clean-up of systems following a severe burnout. • Liquid line filter drier for burnout clean-up and wax removal.

Nomenclature Example: BOK 305S-HH BOK

30

5

S

HH

S = ODF UNIT SIZE CONNECTION SIZE CHARCOAL SERIES CONNECTIONS (IN CU. IN.) (IN 1/8”) BLEND (OMIT FOR SAE) SOURCE 1 PART NO. S1-060241 S1-060242 S1-060229 S1-060231 S1-060232 S1-060234 S1-060236

VENDOR TYPE NO.

CONNECTION SIZE

A

B

BOK-163-HH BOK-163S-HH BOK-164S-HH BOK-165S-HH BOK-303-HH BOK-304S-HH BOK-305S-HH

3/8 SAE 3/8 ODF 1/2 ODF 5/8 ODF 3/8 SAE 1/2 ODF 5/8 ODF

6-3/4 6-1/8 6-3/16 6-3/8 9-5/8 9-1/8 9-5/16

— 5-1/4 5-3/16 5-1/8 — 8-1/8 8-1/16

DIMENSIONS D — 7/16 1/2 5/8 — 1/2 5/8

E

F*

SHIP WT. (LBS.)

3-15/16

2-15/16

1

4-5/8

2-7/8

2

7-1/2

3-1/16

3-3/4

MLP $41.69 41.44 45.94 47.37 80.28 81.04 81.04

* Does not include weld bead

88

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

DRIERS & FILTERS

ALF Liquid Filter The ALF liquid line refrigerant filter is ideal for protecting solenoid and expansion valve parts from debris. Application: • Liquid Line Filter. • Recovery, recycle and reclaim filter. Features: • Filtering media that maximizes removal of finer particles. • Corrosion resistant epoxy powder paint finish.

Specifications: Filtration: 40 microns Maximum working pressure: 500 psig UL file number: SA 3124 CSA file number: LR 100624, LR 32462

Nomenclature Example: ALF 033S ALF

03

3

S

S = ODF CONNECTION STYLE CONNECTION SIZE INLET OMIT FOR SAE (MALE IN/MALE OUT) SERIES UNIT SIZE (IN 1/8”) MF = MALE SAE IN/FEMALE SAE OUT FM = FEMALE SAE IN/MALE SAE OUT SOURCE 1 PART NO.

VENDOR TYPE NO.

S1-057193

ALF-032MF

S1-064778

ALF-052MF

CONNECTION SIZE

DIMENSIONS B*

A

1/4 SAE MALE IN 1/4 SAE FEMALE OUT 1/4 SAE MALE IN 1/4 SAE FEMALE OUT

C

MLP

2-9/16

1-5/8

4

$17.98

3

2-5/8

4-3/8

23.62

* Does not include weld bead

ASD Premium Suction Line Filter-Drier Application: • Emerson Climate Technologies’ ASD is a premium suction line filter-drier that incorporates beaded desiccant plus a filter. • Premium suction line filter drier for moisture, acid and contaminant removal. • For use with CFC, HCFC and HFC refrigerants. Features: • Premium filtration • Dual access valves • Solid copper fittings

• Corrosion resistant epoxy powder paint finish Specifications: Filtration: 40 microns Maximum working pressure: 500 psig UL file number: SA 3124 CSA file number: LR 100624, LR 32462

Nomenclature Example: ASD-35S5VV ASD

35

S

5

VV

UNIT SIZE S = ODF CONNECTIONS CONNECTION SIZE SERIES DUAL ACCESS VALVES (IN CU. IN.) F = SAE (IN 1/8”) l

SOURCE 1 PART NO. S1-049171 S1-049172 S1-049173 S1-049174 S1-049175 S1-049176

VENDOR TYPE NO.

CONNECTION SIZE

A

ASD-35S5-VV ASD-45S6-VV ASD-45S7-VV ASD-50S9-VV ASD-75S11-VV ASD-75S13-VV

5/8 ODF 3/4 ODF 7/8 ODF 1-1/8 ODF 1-3/8 ODF 1-5/8 ODF

6-17/32 7-3/4 7-15/16 8-27/32 12-1/4 12-5/32

DIMENSIONS (IN INCHES) B C D 5-9/32 6-1/2 6-7/16 7-1/32 10-5/16 9-29/32

5/8 5/8 3/4 29-32 31-32 1-1/8

E *

4-3/4 5-9/16 6-1/8 8-1/4

3-11/16 3-11/16 3-11/16 3-11/16 3-11/16 3-11/16

SHIP WT. (LBS.) 2-1/2 3 3-1/2 5

MLP $ 99.20 113.55 69.09 135.05 186.94 193.63

* Does not include weld bead.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

89


hemrichelectric.com

info@hemrichelectric.com

DRIERS & FILTERS

SFD Suction Line Filter-Drier

Application: • Emerson Climate Technologies’ standard compacted bead suction filter-drier for use after a burnout or when major work has been performed.

• Suction line filter drier for moisture, acid and contaminant removal. • For use with CFC, HCFC and HFC refrigerants. Features: • Solid copper fittings • Dual access valves • Corrosion resistant epoxy powder paint finish Specifications: Filtration: 40 microns Maximum working pressure: 400 psig UL file number: SA 3124

CSA file number: LR 100624, LR 32462

Nomenclature Example: SFD-13S5-VV SFD

13

S

5

VV

UNIT SIZE S = ODF CONNECTIONS CONNECTION SIZE SERIES DUAL ACCESS VALVES (IN CU. IN.) F = SAE (IN 1/8”) SOURCE 1 PART NO. S1-064042 S1-064044 S1-064043 S1-064045 S1-064046 S1-064047 S1-060247 S1-060248 S1-060249 S1-060250 S1-060262 S1-056505 S1-060251 S1-060252 S1-060253

VENDOR TYPE NO.

CONNECTION SIZE

A

SFD-08F3-VV SFD-08S3-VV SFD-08F4-VV SFD-08S4-VV SFD-08S5-VV SFD-08S6-VV SFD-13S4-VV SFD-13F5-VV SFD-13S5-VV SFD-13S6-VV SFD-13S7-VV SFD-27S6-VV SFD-27S7-VV SFD-27S9-VV SFD-54S11-VV

3/8 SAE 3/8 ODF 1/2 SAE 1/2 ODF 5/8 ODF 3/4 ODF 1/2 ODF 5/8 SAE 5/8 ODF 3/4 ODF 7/8 ODF 3/4 ODF 7/8 ODF 1-1/8 ODF 1-3/8 ODF

N/A 5-5/16 N/A 3-15/16 3-29/32 4-5/16 3-15/16 — 3-29/32 4 4-1/4 5-3/4 6 5-13/16 10-5/16

DIMENSIONS (IN INCHES) B C

3-3/8

5-1/8 8-1/4

5-1/2 6-3/16 5-3/4 5 5-5/32 5-9/16 4-15/16 6-1/8 5-5/32 5-1/4 5-3/4 7 7-1/2 7-5/8 12-1/4

SHIP WT. (LBS.)

D

3-1/8 2

3-11/16 3

MLP $54.17 54.17 54.42 59.74 58.34 57.94 61.91 64.83 64.13 66.50 66.95 94.29 92.03 98.38

4-1/2

CSFD Compact Suction Line Filter-Drier

Application: • The CSFD has a compact 14 cubic inch, solid block desiccant core design that is perfect for short lay-ins.

• Compact suction line filter drier for moisture, acid and contaminant removal. • For use with CFC, HCFC and HFC refrigerants. Features: • Dual access valves • High acid removal • Solid copper fittings • Corrosion resistant epoxy powder paint finish Specifications: Filtration: 40 microns Maximum working pressure: 500 psig, except as noted

UL file number: SA 3124 CSA file number: LR 100624

Nomenclature Example: CSFD-14S4-VV CSFD

14

S

4

VV

CONNECTION SIZE DUAL ACCESS SERIES UNIT SIZE S = ODF CONNECTION (IN 1/8”) VALVES SOURCE 1 PART NO. S1-062231 S1-062232 S1-062233 S1-062234 S1-062235

VENDOR TYPE NO.

CONNECTION TYPE (INCHES)

A

CSFD-14S4-VV CSFD-14S5-VV CSFD-14S6-VV CSFD-14S7-VV CSFD-14S9-VV*

1/2 SOLDER 5/8 SOLDER 3/4 SOLDER 7/8 SOLDER 1-1/8 SOLDER

4-1/4 4-1/2 4-3/8 4-9/16 4-7/8

DIMENSIONS (IN INCHES) B

2-3/4

C

MLP

4-5/8

$69.93 67.27 70.84 72.74 78.18

* Maximum working pressure: 400 psig

90

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

DRIERS & FILTERS

STAS Steel Liquid and Suction Filter-Drier

Application: Replaceable core filter-drier for CFC, HCFC and HFC refrigerants for use in large commercial air conditioning and refrigeration systems.

Features: • Unique internal hardware for hassle-free installation. • Full flow fittings for low pressure drop. • Corrosion resistant epoxy powder paint finish. • Sturdy steel shells for long life durability. • Solid copper fittings. • 100 mesh outlet screen. Specifications: Filtration (with block): 40 microns UL file number: SA 3124 CSA file number: LR 100624, LR 32462 Bolt torque: 25 foot-lbs STAS models are shipped without filter cores or filter-drier blocks.

Nomenclature Example: STAS 489T STAS

48

9

T

SYSTEM SERVICE UNIT SIZE CONNECTION SIZE SYSTEM PROTECTOR SERIES T = LIQUID LINE SERVICE (IN CU. IN.) (IN 1/8”) SV = SUCTION LINE SERVICE

SOURCE 1 PART NO.

MAXIMUM WORKING PRESSURE (PSIG)

VENDOR TYPE NO.

CONNECTION SIZE & TYPE

S1-053001 S1-053003 S1-053005

STAS-485T STAS-487T STAS-489T

5/8 ODF 7/8 ODF 1-1/8 ODF

680

S1-053047

STAS-9617S-V*

2-1/8 ODF

400

S1-053030

STAS-19213T

1-5/8 ODF

500

SYSTEM SERVICE LIQUID LINE SUCTION LINE LIQUID LINE

DIMENSIONS

DESICCANT VOLUME (CU. IN.)

NO. OF BLOCKS 1

48

A

B

C

D

MLP

9-15/32 9-11/16 9-3/4

6 6-1/4 6-5/16

3-25/32 3-3/4 3-27/32

5/8 25/32 15/16

$319.81 325.60 325.60

2

96

15-9/16

12-1/32

4-9/16

1-11/32

496.31

4

192

26-15/16

23-9/16

4-1/32

1-1/8

536.63

* “SV” style include stainless steel bolts and access valve.

Blocks and Filter Core Application: Universal replacement cores for use in Emerson Climate Technologies and all other takeapart type filter-drier shells. Features: • Water capacities to suit specific system conditions. • Exceptional acid capacities for normal system protection, or to effectively clean-up following a compressor burnout. SOURCE 1 PART NO. S1-056662 S1-059541

VENDOR TYPE NO.

RECOMMENDED REFRIGERANT TYPE

D42 D-48

CFC,HCFC CFC, HCFC

S1-059542

H-48

CFC, HCFC

S1-061617

UK-48

CFC, HCFC, HFC

S1-047664

F-48R

CFC, HCFC, HFC

FUNCTION

Specifications: Interchangeable with competitive products. NOTE: Blocks are suitable for use with R-11 but filters are not suitable. Nomenclature H

48

SERIES CUBIC INCH

WATER CAPACITY (IN DROPS OF WATER*) R-12 R-134A R-22 R-407C R-404A507 R-502 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F 75°F 125°F

HIGH ACID REMOVAL 782 HIGH ACID REMOVAL 810 HIGH ACID AND 1020 WATER REMOVAL UNIVERSAL 1579 REPLACEMENT FILTER (SUCTION ONLY) — REVERSE FLOW

515 453

493 415

384 340

432 363

303 254

320 225

196 95

528 457

378 343

473 388

MLP

339 225

$49.37 36.50

688

676

538

597

436

445

285

721

535

643

475

62.76

1319

1272

1168

1181

1072

1033

786

1319

1241

1332

1150

65.61

40.48

* 20 drops of water = 1 gram = 1 cc

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

91


hemrichelectric.com

info@hemrichelectric.com

D Series Copper Spun Driers DRIERS CONTAIN XH-9 DESSICANT

D109

D111

D114

D112

For use on both domestic and commercial refrigerators, freezers and air conditioners. All the driers listed are compatible with all the refrigerants. SIZE CHART

PART NO. D109 D111 D112 D114 PART NO. S1-D109 S1-D111 S1-D112 S1-D114

DROPS OF WATER REMOVED R-12 R-22 75° 125° 75° 125° 38 74 99 74

34 68 93 68

34 68 95 68

RECOMMENDED TONNAGE R-12 R-22

32 64 90 64

1/3 3/4 1 3/4

1/2 1 2 1

DESCRIPTION

DIA.

LENGTH

INLET

OUTLET

PACKAGE QTY.

MLP PER EACH *

NON DIRECTIONAL DRIER DIRECTIONAL CHARGING DRIER DIRECTIONAL STEP DOWN DRIER DIRECTIONAL FUSED ENDS DRIER

3/4” 1” 1” 1”

8-1/2” 8-3/4” 10-3/4” 9”

1/4” 1/4” 5/16” MULTIPLE

1/4" 1/4" OR CAP 5/16" 1/4"

5 5 5 5

$3.28 6.77 5.98 5.19

* Sold by the package only

92

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SPORLAN DRIERS

Catch-All Liquid Line Filter-Driers Features: • Leakproof shell • Solid copper sweat fittings • Outlet safety filter • A blend of desiccants for maximum moisture removal • Lower end point dryness levels

LIQUID LINE FILTER DRIERS DIMENSIONS

SOURCE 1 PART NO. S1-52636200000 S1-52636201000 S1-52636202000 S1-52636203000 S1-52635463000 S1-52636204000 S1-52634088000 S1-52636206000 S1-52636207000 S1-52636209000 S1-52636210000 S1-52635038000 S1-52636211000 S1-52634506000 S1-52636213000 S1-52636214000 S1-52636215000 S1-52609900000 S1-52636217000 S1-52636218000 S1-52631471000

SPORLAN MODEL NO.

CONNECTION SIZE & TYPE

BODY DIAMETER B

LENGTH A

SURFACE FILTERING AREA SQ. IN.

C-032S C-033S C-052S C-0525S C-053S C-082S C-083S C-084S C-162S C-163S C-164S C-165S C-303S C-305S C-306S C-307S C-309S C-414S C-417S C-419S C-607S

1/4 ODF 3/8 ODF 1/4 ODF 5/16 ODF 3/8 ODF 1/4 ODF 3/8 ODF 1/2 ODF 1/4 ODF 3/8 ODF 1/2 ODF 5/8 ODF 3/8 ODF 5/8 ODF 3/4 ODF 7/8 ODF 1-1/8 ODF 1/2 ODF 7/8 ODF 1-1/8 ODF 7/8 ODF

1.75 1.75 2.44 2.44 2.44 2.62 2.62 2.62 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.50 3.50 3.50 3.00

3.81 3.88 4.75 4.38 4.31 5.12 5.25 5.44 5.75 5.88 6.00 6.31 8.88 9.25 9.65 9.80 9.75 9.05 9.81 9.75 16.00

9 9 15 15 15 21 21 21 33 33 33 33 53 53 53 53 30 67 67 67 106

HCFC-22 WATER CAP DROPS AT 60 PPM 75°F 125°F 61 61 146 146 146 240 240 240 364 364 364 364 696 696 696 696 696 936 936 936 1392

REFRIG. FLOW CAPAC @ 2 PSI PRESS. DROP (TONS)

SHIPPING WEIGHT (LBS.)

MLP

2.1 5.3 2.9 4.8 6.6 2.9 7.3 13.4 2.9 7.3 15.4 22.3 7.4 23.7 27.6 30.2 34.4 17.4 30.9 34.0 40.7

.50 .50 .75 .75 .75 1.25 1.25 1.25 1.75 1.75 1.75 1.75 3.50 3.50 3.50 3.50 3.50 4.50 4.50 4.50 6.00

$ 18.07 19.54 22.14 23.53 30.75 29.37 42.80 29.66 36.64 36.30 51.88 55.46 71.05 70.08 69.96 71.09 77.39 92.14 120.66 95.55 168.81

50 50 119 119 119 196 196 196 297 297 297 297 567 567 567 567 567 763 763 763 1134

Reversible Heat Pump Filter-Driers

Features: • A short overall length for easy installation. • Drier operates in either flow direction with low pressure drop.

SOURCE 1 PART NO. S1-52636219000 S1-52636220000 S1-52634410000 S1-52636221000 S1-52636222000

SPORLAN MODEL NO.

CONNECTION SIZE & TYPE

HPC-103-S HPC-104-S HPC-163-S-HH HPC-164-S-HH HPC-165-S-HH

3/8 ODF 1/2 ODF 3/8 ODF 1/2 ODF 5/8 ODF

• Proven metal check valves used in construction – no synthetic materials. • The Sporlan dependable molded core used for maximum filtration ability. When the flow direction reverses, dirt already collected remains in the filter-drier. • A carefully engineered blend of desiccants for maximum water capacity and acid removal ability. The HPC-160-HH Series also has the HH style core with activated charcoal which offers maximum ability to remove oleoresin and other reactive chemical constituents in the oil.

• Same rugged construction as used in the Catch-All.

REVERSIBLE HEAT PUMP FILTER DRIERS DIMENSIONS HCFC-22 WATER CAP REFRIG. FLOW CAPAC. DROPS (125°) SURFACE @ 2 PSI AT 60 PPM FILTERING BODY PRESS. DROP DIAMETER B LENGTH A AREA SQ. IN. 75°F 125°F (TONS) 3.00 3.00 3.00 3.00 3.00

5.88 6.00 6.92 7.07 7.35

18 18 26 26 26

215 215 93 93 93

176 176 81 81 81

4.7 6.3 5.1 5.6 6.8

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

SHIPPING WEIGHT (LBS.)

MLP

1.75 1.75 1.75 1.75 1.75

$50.80 51.47 74.29 75.55 75.25

93


hemrichelectric.com

info@hemrichelectric.com

SPORLAN FILTERS

SF – Suction Filter • • • • •

Features: •Protects the compressor from dirt •A relief device opens if the filter plugs

Suitable for use with all brazing alloys Full flow design for low pressure drop Maximum corrosion resistance Complete line of sizes With the exclusive Bi-directional feature RATINGS AT ARI STANDARD 730 CONDITIONS WATER CAPACITY REFRIGERANT DROPS AT 60 PPM FLOW CAPACITY 75°F 125°F TONS AT 3 PSI ∆P

SPORLAN PART NO. SOURCE 1 PART NO.

W/O ACCESS VALVE

S1-52636248000 S1-52636249000 S1-52636250000 S1-52636251000 S1-52636252000 S1-52636253000

— — — — — —

S1-52636256000 S1-52636257000

SF-115 —

CONNECTION SIZE & TYPE

W/ACCESS VALVE

FILTER AREA SQ. IN.

OVERALL LENGTH

SHELL DIA.

SHIPPING WEIGHT (LBS.)

TYPES WITH BYPASS RELIEF VALVE (BI-DIRECTIONAL FLOW) SF-285-T 5/8 ODF 28 8.34 3.0 2.25 SF-286-T 3/4 ODF 28 8.79 3.0 2.25 SF-287-T 7/8 ODF 28 8.93 3.0 2.25 SF-289-T 1-1/8 ODF 28 9.51 3.0 2.25 SF-489-T 1-1/8 ODF 48 12.42 3.0 3.0 SF-4811-T 1-3/8 ODF 48 13.10 3.0 3.0 TYPES WITHOUT BYPASS RELIEF VALVE (SINGLE FLOW DIRECTION) 5/8 ODF 11 4.60 2.00 .75 SF-6417-T 2-1/8 ODF 388* 10.94 4.75 7.50

MLP

N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A

6.4 8.6 11.1 14.8 16 18.4

$ 71.39 76.81 76.81 81.64 119.41 119.41

N/A N/A

N/A N/A

4.1 91.1

33.87 285.00

* The SF-6400 series uses a pleated filter that greatly increases the square inch filter area. SELECTION RECOMMENDATIONS * FLOW CAPACITY IN TONS EVAPORATOR TEMPERATURE 40° F. 20° F. 0° F. –20° F. PRESSURE DROP 2 3 1-1/2 2 1 1-1/2 1/2 1 REFRIGERANT 134A 22 12 134A 22 12 134 22 12 22

TYPE NUMBER

WITHOUT ACCESS VALVE

WITH ACCESS VALVE

CONNECTIONS INCHES

12

SF-114 SF-115 – – – – – – – – –

– – SF-285-T SF-286-T SF-287-T SF-289-T SF-489-T SF-4811-T SF-4813-T SF-6417-T SF-6421-T

1/2 ODF 5/8 ODF 5/8 ODF 3/4 ODF 7/8 ODF 1-1/8 ODF 1-1/8 ODF 1-3/8 ODF 1-5/8 ODF 2-1/8 ODF 2-5/8 ODF

1.3 2.3 3.5 4.3 6.3 8.2 8.7 9.9 11.7 46.7 50.5

1.5 2.6 4.0 5.1 7.0 9.2 9.9 11.2 13.3 50.9 62.9

2.4 4.1 6.4 8.6 11.1 14.8 16.0 18.4 21.6 91.1 119.0

0.9 1.6 2.5 3.1 4.4 5.7 6.1 6.8 8.1 28.7 36.8

1.0 1.7 2.7 3.4 4.6 6.0 6.5 7.3 8.7 31.0 38.6

1.5 2.7 4.0 5.0 7.2 9.4 10.0 11.4 13.5 56.9 70.2

0.6 1.0 1.6 2.0 2.7 3.5 3.7 4.2 4.9 15.8 20.2

0.6 1.1 1.7 2.1 2.8 3.7 3.9 4.4 5.2 16.4 20.6

1.1 1.8 2.9 3.6 5.1 6.6 7.0 7.9 9.4 31.8 44.0

0.3 0.5 0.9 1.1 1.4 1.8 1.9 2.2 2.6 7.2 9.1

–40° F. NOMINAL SYSTEM HORSEPOWER REFRIGERANT 22 12, 134A, 502

1/2 22

0.7 1.2 1.8 2.2 3.1 4.0 4.3 4.8 5.6 20.3 25.6

0.3 0.6 1.0 1.2 1.5 2.1 2.2 2.5 2.9 9.3 11.8

1 2 4 5 7-1/2 7-1/2 10 12 15 55 60

1/2 1 1-1/2 1-1/2 3 5 5 5 7 20 30

*Refrigerant 502 flow capacity is 80% of the values shown for Refrigerant 22, when expressed in TONS. When expressed in horsepower, the proper refrigerant selection is the same as for R-12.

See-All Moisture and Liquid Indicator Features: •Extremely accurate SOURCE 1 PART NO.

• Full view sight glass • Indicator protected by filter pad and screen SEE ALL MOISTURE & LIQUID INDICATOR CONNECTION DWG. NO. SIZE AND TYPE

SPORLAN PART NO.

S1-52636239000 S1-52636240000 S1-52636241000 S1-52636242000 S1-52636243000 S1-52636244000 S1-52636245000 S1-52636246000 S1-52636247000

SA-12FM SA-13FM SA-14FM SA-12S SA-13S SA-14S SA-15S SA-17S SA-19S

SA-1 SA-1 SA-1 SA-2 SA-2 SA-2 SA-2 SA-2 SA-2

1/4 SAE M X 1/4 SAE F 3/8 SAE M X 3/8 SAE F 1/2 SAE M X 1/2 SAE F 1/4 ODF 3/8 ODF 1/2 ODF 5/8 ODF 7/8 ODF 1-1/8 ODF

• Replaceable indicator element OVERALL LENGTH

SHIPPING WT. (LBS.)

MLP

2.56 2.97 3.44 4.62 4.62 4.87 4.87 6.31 6.31

.50 .50 .63 .50 .50 1.00 1.00 1.50 1.50

$29.16 30.46 36.89 29.79 30.46 49.65 37.77 57.41 57.06

MOISTURE CONTENT PPM REFRIGERANTS 11 & 12 SEE-ALL SHOWS Green DRY Chartreuse CAUTION Yellow WET

REFRIGERANT 22

REFRIGERANT 134A LIQUID LINE TEMP. 75° 100° 125°

75°

100°

125°

75°

100°

125°

BELOW 5

BELOW 10

BELOW 20

BELOW 30

BELOW 45

BELOW 60

BELOW 50

BELOW 80

BELOW 110

REFRIGERANTS 502, 113 & 114

REFRIGERANTS 404A & 507

75°

100°

125°

75°

100°

BELOW 10

BELOW 20

BELOW 30

BELOW 15

BELOW 30

5 - 15

10 - 30

20 - 50

30 - 90

45 - 130

60 - 180

50 - 200

80 - 225

110 - 310

10 - 45

20 - 65

30 - 110

15 - 90

30 - 140

ABOVE 15

ABOVE 30

ABOVE 50

ABOVE 90

ABOVE 130

ABOVE 180

ABOVE 200

ABOVE 225

ABOVE 310

ABOVE 45

ABOVE 65

ABOVE 110

ABOVE 90

ABOVE 140

NOTE: Change or add Catch-All Filter-Drier when paper turns from green to chartreuse. Bold figures are for the average design conditions of refrigerant liquid lines operating at 100°F. Since the actual temperature is not critical, a satisfactory estimate can be made by comparint it to body temperature. If it feels cool to the touch, use 75°F; if it feels warm, use 125°F column figures.

94

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SPORLAN DRIERS

Replaceable Core Filter-Driers • Nut and bolt attachment at end plate allows for simple installation • Tie-rod construction for easy core replacement • All internal parts are plated steel • Exterior shell painted to prevent corrosion

Features: •Molded porous coremaximum water capacity SOURCE 1 PART NO.

SPORLAN PART NO.

CONNECTION SIZE & TYPE

NO. OF CORES

S1-52636223000

C-R424

1/2 ODF

1

S1-52636226000 S1-52636227000

C-487 C-489-G

7/8 ODF 1-1/8 ODF

1 1

S1-52636228000

C-4811-G

1-3/8 ODF

1

CORE PART NO. RC-4267 OR RCW-42 RC-4864 RC-4864-HH OR RCW-48

DIMENSIONS

VOLUME OF DESICCANT CU. IN.

A

B

C

D

42

9.00

4.75

6.76

2.81 3.50 .50

48 48

9.30 9.50

6.00 5.00 6.00 5.00

6.07 6.37

3.72 4.75 .75 3.78 4.75 .91

48

9.60

6.00 5.00

6.37

3.94 4.75 .97

E

F

G

** P

SHIP WT.

MLP

6.50

6.50

$219.54

7.50 7.50

12.00 12.00

346.90 337.04

7.50

12.00

347.09

* * P Indicates pull space required to change core.

Filter Cores Features: •Individually packaged in metal cans •Fully activated •Hermetically sealed • Instructions on each can for easy installation • Includes a triple gasket SOURCE 1 PART NO.

SPORLAN PART NO.

RC-4864 – Activated Core - order as separate item - fits types C-480 thru C-19200 series shells. This is the standard core suitable for most installations in the liquid line or suction line. RC-4864-HH – Activated Charcoal Core – order as separate item - fits types C-480 thru C-19200 series shells. This core should be used for wax removal on low temperature R-22 and R-502 systems, and for clean-up after hermetic motor burnout on all types of systems. REPLACEABLE CORES CORE DIMENSIONS SHIPPING O.D. X LENGTH WEIGHT (LBS.)

RCW-42 — High Water Capacity Core — Order as separate item — Fits ONLY shell types C-R424, C-R425, and C-R427. Designed specially for use with POE oils. This core should be used on systems that have a ruptured water cooled condenser, or that have been exposed to the atmosphere, or for some reason have a high amount of moisture in the system.

FOR USE WITH REPLACEABLE FILTER DRIER

MLP

C-R424, C-R425 AND C-R427 C-480 THRU C-19200 C-480 THRU C-19200

$46.97 42.73 66.43

j

S1-52636235000 S1-52636236000 S1-52636237000

RCW-42 RC-4864 RC-4864-HH

3.18” X 6.00” 3.74” X 5.50” 3.74” X 5.50”

2.20 2.33 2.33

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

95


hemrichelectric.com

info@hemrichelectric.com

Parker Suction Line Accumulators Features: • Solid copper connections • “U” tube design for maximum flow of refrigerant and minimum oil entrapment • Inlet Flow Director guides refrigerant toward wall for smooth tangential flow and gradual expansion • “U” tube entrance is positioned behind the Inlet Flow Director to prevent unwanted liquid refrigerant from entering and damaging compressor • Metering Orifice matched to system capacity assures optimum liquid refrigerant and oil flow back to compressor • Protective Screen and Orifice Assembly on “U” Tube protects against foreign particles and contaminants affecting metering function • Fittings and “U” Tube are matched to accumulator holding capacity and total system charge for minimum pressure drop and maximum refrigerant flow

SOURCE 1 PART NO. S1-02625573001 S1-02625573002 S1-02625573003 S1-02625573004 S1-02625573005 S1-02631681001 S1-02631681002 S1-02631681004

96

VENDOR MODEL NO.

OVERALL HT (H)

CAN HT (A)

089176-01 089213-01 089214-01 089175-01 089215-01 089163-00 089164-01 089171-01

11.3 12.9 15.3 11.3 17.3 9.6 9.6 11.3

9.6 11.2 13.6 9.6 15.5 8.3 8.3 9.6

• U.L. listed for 1775 psig minimum bursting pressure • Powder paint exterior coating surpasses 500 hour ASTM salt spray tests • Integral 430°F Fuse Plugs

ACCUMULATOR DIMENSIONS CAN SYSTEM DIA CONN CAPAC (D) I.D. (OZ) 5.0 5.0 5.0 5.0 5.0 4.0 5.0 5.0

STOCKED NON STOCKED

3/4” 7/8” 7/8” 7/8” 7/8” 3/4” 3/4” 7/8”

111 125 156 108 179 58 89 108

ORIFICE DIA.

MLP

0.040 0.040 0.040 0.040 0.040 0.026 0.026 0.035

$ 96.99 91.70 122.12 94.95 120.23 93.41 94.05 100.77

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

MOISTURE INDICATORS

HMI Liquid Moisture Indicator

Application: • The HMI was designed to provide an accurate method of determining the moisture content of a system’s refrigerant. • Unique 3% high accuracy moisture indicator for CFC, HCFC and HFC refrigerants, including R410A Features: • Fully hermetic design

• Solid copper fittings Specifications: 3% relative humidity sensitivity Maximum working pressure: 680 psig UL file number: SA 4876 CSA file number: LR 32462

• 3% relative humidity indication compared to 10% paper indicators • Single indicator for all common refrigerants • Accurate color calibration at low ppm levels and higher temperatures • Wide angle viewing/high visibility window for ease of monitoring • All brass corrosion resistant body

Nomenclature Example: HMI-1TT4 HMI HERMETIC MOISTURE INDICATOR SOURCE 1 PART NO. S1-065405 S1-065406 S1-065407 S1-065408 S1-065410

1 SERIES

TT

4

CONNECTION STYLE TT = SWEAT X SWEAT

CONNECTION SIZE (IN 1/8”)

DIMENSIONS (IN INCHES) D

VENDOR TYPE NO.

CONNECTION

A

C

HMI-1TT2 HMI-1TT3 HMI-1TT4 HMI-1TT5 HMI-1TT7

1/4 X 1/4 ODF 3/8 X 3/8 ODF 1/2 X 1/2 ODF 5/8 X 5/8 ODF 7/8 X 7/8 ODF

5.56 ± 0.08 5.61 ± 0.08 5.87 ± 0.08 5.87 ± 0.08 6.31 ± 0.10

0.34 ± 0.06 0.34 ± 0.06 0.47 ± 0.06 0.61 ± 0.06 0.61 ± 0.06

0.937 ± 0.06 0.937 ± 0.06 1.187 ± 0.06 1.187 ± 0.06 1.675 ± 0.06

∅E

F MIN

MLP

0.254 ± 0.002 0.379 ± 0.002 0.504 ± 0.003 0.629 ± 0.003 0.879 ± 0.003

0.375 0.402 0.500 0.625 0.750

$26.99 28.26 33.85 42.62 51.75

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

97


hemrichelectric.com

info@hemrichelectric.com

THERMOSTATIC EXPANSION VALVES

TRAE+ Thermo® Expansion Valve conditioning, heat pump, and chiller applications. The new series introduces a new replaceable stainless steel power element, a fully interchangeable cage assembly and a square body. This valve type features double balanced port design, which provides stable and accurate control over wide loads and evaporator temperature ranges. Furthermore, a permanent inlet strainer and external adjustment are standard on every valve. Features: • Suitable for Bi-Flow applications. • Removable power element and cage assembly for full serviceability. • Stainless steel power element for enhanced corrosion resistance. • Double balanced port design improves operation and stability under low load conditions.

Emerson Climate Technologies’ TRAE Plus thermostatic expansion valve (TSV) is a large capacity series designed for refrigeration, air

• • • • •

Square body with straight-thru connections. Solid copper connections. External superheat adjustment. Large diaphragm provides superior stability. HCA charge designed especially for R22 air conditioning applications. Options: • Cages KT20289 through KT20293 • Remote Bulb Tubing Length 10’ standard; other lengths are available. • Replaceable Power Assembly X-28458 Specifications: Ratings from 10 to 40 tons. Maximum working pressure: 450 psig Torque Power Assembly: 375–425 in. lb. Torque Cage: 60 in. lb.

Nomenclature Example: TRAE+ 30 HC 10 FT 7/8X1 1/8 ODF S/T TRA

E

VALVE SERIES

EQUALIZER

+

30

H

C

10 FT

7/8 X 1-1/8

ODF

S/T

REPLACEABLE CAPACITY REFRIGERANT CHARGE CODE CAPILLARY INLET X OUTLET CONNECTION CONFIGURATION COMPONENTS Nominal Rating CODE TUBE LENGTH CONNECTION TYPE in Tons SIZES F = R12 H = R22 C = medium temp 10 FT (See nominal M = R134A CA = heat pump 5/8 x 7/8 S/T = STRAIGHTE=EXTERNAL Cage & Power (Standard) ODF = SOLDER capacity N = R407C W(MOP) = press. 7/8 x 1-1/8 THROUGH 1/4��� SAE Assembly Other lengths (ONLY) table below) P = R507 Limiting 1-1/8 x 1-3/8 (ONLY) are available R = R502 Z = low temp S = R404A

TRAE+ Series Nominal Capacity Table in Tons (kWatts) R12

R134A

R22

R502

R507/R404A

R407C

7-1/2 (27) 10 (35) 12 (42) 18 (64) 25 (88)

9 (32) 13 (46) 14 (50) 22 (78) 30 (106)

10 (35) 15 (53) 20 (71) 30 (106) 40 (142)

8 (28) 12 (42) 14 (50) 20 (71) 30 (106)

8 (28) 12 (42) 14 (50) 20 (71) 30 (106)

10 (35) 15 (53) 20 (71) 30 (106) 40 (142)

TRAE+ Dimensional Data (Inches) TRAE NOMINAL VALVE INLET SIZES (ODF) TYPE (B) OUTLET (E)

TRAE+ 10–40 TONS

5/8 5/8 7/8 7/8 7/8 1-1/8 1-1/8 1-1/8

SOURCE 1 PART NO. S1-062718 S1-062721 S1-063650 S1-062727

98

7/8 1-1/8 7/8 1-1/8 1-3/8 1-1/8 1-3/8 1-3/8

INLET

OUTLET

A

C

D

F

1.57 1.57 2.09 2.09 2.09 2.21 2.21 2.21

0.50 0.50 0.75 0.75 0.75 0.91 0.91 0.91

2.09 2.21 2.09 2.21 2.39 2.21 2.39 2.39

0.75 0.91 0.75 0.91 0.97 0.97 0.97 0.97

VENDOR TYPE NO.

MLP

TRAE+ 10 HC SAE EE 5 FT 5/8X7/8 ODFS/T 6A TRAE+ 15 HC SAE EE 10FT 7/8X1 1/8 ODFS/T 6A TRAE+ 20 HC SAE EE 10 FT 7/8X1 3/8 ODFS/T 6A TRAE+ 30 HC SAE EE 10FT 7/8X1 1/8 ODFS/T 6A

$220.44 259.25 262.42 262.42

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SPORLAN THERMOSTATIC EXPANSION VALVES

“O” Series Expansion Valves Sporlan Type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve type features a balanced port construction, and it is designed for both air conditioning and refrigeration applications. A synthetic seating surface provides tight shut-off during system off periods. This valve type has two body styles: a small body which provides capacities up to 30 tons R-22, and a large body which extends capacities to 70 tons R-22.

Features: • Balanced port construction • External equalizer with 1/4” ODF connection • Connections in straight through flow configuration • Remote bulb tubing length 60” (152 cm) • Standard factory air test superheat setting at 7° F

“S” Series Expansion Valves Sporlan Type S valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable and the inlet connection has a permanent 12 mesh strainer. This valve is designed for both air conditioning and refrigeration applications.

SOURCE 1 PART NO.

Features: • External equalizer with 1/4” ODF connection • Connections in straight through flow configuration • Remote bulb tubing length 60” (152 cm) • Standard factory air test superheat setting at 7° F

CONNECTION SIZE INLET OUTLET

SPORLAN PART NO.

CAPACITY RANGE TONS

S1-52636280000 S1-52636281000 S1-52636282000 S1-52636283000 S1-52636284000

OVE-15-GA-7/8 X 1-1/8 X 1/4 X 5’ OVE-20-GA-7/8 X 1-3/8 X 1/4 X 5’ OVE-30-GA-1-1/8 X 1-3/8 X 1/4 X 5’ OVE-40-GA-1-1/8 X 1-3/8 X 1/4 X 5’ OVE-55-GA-1-1/8 X 1-3/8 X 1/4 X 5’

15 20 30 40 55

7/8 ODF 7/8 ODF 1-1/8 ODF 1-1/8 ODF 1-1/8 ODF

S1-52636286000 S1-52636287000 S1-52636288000 S1-52636290000 S1-52636291000

SVE-2-GA-1/2 X 5/8 X 1/4 X 5’ SVE-3-GA-1/2 X 5/8 X 1/4 X 5’ SVE-4-GA-1/2 X 7/8 X 1/4 X 5’ SVE-8-GA-5/8 X 7/8 X 1/4 X 5’ SVE-10-GA-5/8 X 7/8 X 1/4 X 5’

2 3 4 8 10

1/2 ODF 1/2 ODF 1/2 ODF 5/8 ODF 5/8 ODF

SHIPPING WT. (LBS.)

MLP

1-1/8 ODF 1-3/8 ODF 1-3/8 ODF 1-3/8 ODF 1-3/8 ODF

3.00 3.00 3.00 5.00 5.00

$279.17 287.54 266.05 469.29 487.61

5/8 ODF 5/8 ODF 7/8 ODF 7/8 ODF 7/8 ODF

3.00 3.00 3.00 3.00 3.00

184.30 189.83 189.83 180.75 183.19

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

99


hemrichelectric.com

info@hemrichelectric.com

SOLENOID VALVES

100RB Solenoid Valves Application: • Used for liquid or discharge gas refrigerant service. • Direct-acting, 2-way, normally closed valve. • Solenoid actuated shut-off valve. Features: • One coil fits all valve sizes. • Extended ends for easy installation (standard). • Long-life molded coils provide water, shock, and vibration protection in coil winding. Options: • Connection sizes to fit your system.

• SAE or ODF connection sizes in 1/4” and 3/8”, 1/4 NPTF. • Coil voltages: 120V 50/60Hz, 208V 50/60 Hz, 24V 50/60Hz • Use with R-22, R-134a, R404A, R-507 Specifications: Maximum fluid temp: 250°F Maximum working pressure: 500 psig MOPD: 300 psig UL file number: MP604 CSA file number: LR44912 CV and TUV approved Note: Mounting enclosing tube more than 90° off vertical up position is not recommended.

Nomenclature Example: 100RB 2F2 VLC 100R

B

2

F

2

VLC

CONNECTION TYPE PORT SIZE F = SAE CONNECTION SIZE VALVE SERIES DESIGN SERIES COIL* (IN 1/16”) S = ODF (IN 1/8”) P = FPT

*Note: Valves are shipped without the solenoid coils (VLC = Valve Less Coil) NOMINAL CAPACITY—TONS (KW) SOURCE 1 PART NO. S1-047503 S1-047504 S1-047505

VENDOR TYPE NO.

CONNECTION SIZE

100RB 2S2 VLC 100RB 2S3 VLC 100RB 2S4 VLC

1/4” ODF 3/8” ODF 1/2” ODF

R12 .80 (2.8)

R134A

R22

.96 (3.4)

1.27 (4.5)

R407C 1.21 (4.3)

R404A/ R507 .85 (3.0)

R502

MLP

.83 (2.9)

$59.48 58.37 58.37

Capacities based on 100°F liquid and 40°F saturated evaporator for ARI standard.

100

VALVE

CONNECTION SIZE

A

B

100RB 2S2 VLC 100RB 2S3 VLC 100RB 2S4 VLC 100RB 2F2 VLC 100RB 2F3 VLC 100RB 2P2 VLC

1/4” ODF 3/8” ODF 1/2” ODF 1/4” SAE 3/8” SAE 1/4” NPTF

4-5/8” (4.63) 4-5/8 (4.63) 4-5/8” (4.63) 2-7/8” (2.88) 3-1/4” (3.25) 1-1/2” (1.50)

5/16” (.31) 5/16” (.31) 3/8” (.38) — — —

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

COILS FOR

SOLENOID VALVES

Solenoid Coil Prefix Selection Table

NOMINAL VOLTAGE & FREQUENCY

VALVE TYPE

J-BOX

CONDUIT

LEADS

SPADES

MOLDED-DIN WITH CONNECTOR

100RB 200RB

AMG

AMC

AMF

AMS

ASC2

APPLIED AMPERES VOLTAGE & FREQUENCY INRUSH HOLDING

24-50/60 24-50/60 120-50/60 120-50/60 208-220/50 208-240/60 208-220/50 208-240/60 208-220/50 208-240/60 208-220/50 208-240/60 480-50/60 480-50/60

24/50 24/60 120/50 120/60

24-50/60 24-50/60 120-50/60 120-50/60 208-220/50 208-240/60 208-220/50 208-240/60 208-220/50 208-240/60 208-220/50 208-240/60 480-50/60 480-50/60

24/50 24/60 120/50 120/60

VA WATTS COIL HOLDING MAX. INSULATION

AM COIL FOR 100RB & 240RA 1.20 0.96 23 1.0 0.74 18 0.25 0.21 25 0.19 0.16 19

208/50

0.14

0.08

17

208/60

0.12

0.06

12

220/50

0.16

0.10

24

240/60

0.13

0.18

19

480/50 480/60

0.06 0.05

0.05 0.04

24 19

AM COIL FOR 200RB 2.00 0.96 1.6 0.74 0.45 0.21 0.36 0.16

17/12

CLASS F MOLDED

23 18 25 19

208/50

0.19

0.08

17

208/60

0.15

0.06

12

220/50

0.24

0.10

24

240/60

0.19

0.08

19

480/50 480/60

0.11 0.09

0.05 0.04

24 19

17/12

CLASS F MOLDED

NOMINAL VOLTAGE & FREQUENCY

APPLIED AMPERES VOLTAGE & FREQUENCY INRUSH HOLDING

VA WATTS COIL HOLDING MAX. INSULATION

ASC2 COIL FOR 200RB 2.18 1.07 26 1.90 0.81 19 0.43 0.21 25 0.38 0.16 19 0.24 0.12 30 0.21 0.09 22

24-50/60 24-50/60 120-50/60 120-50/60 240-50/60 240-50/60

24/50 24/60 120/50 120/60 240/50 240/60

24-50/60 24-50/60 120-50/60 120-50/60 240-50/60 240-50/60

ASC2 COIL FOR 100RB & 240RA 24/50 1.67 1.10 26 24/60 1.41 0.83 20 120/50 0.31 0.22 26 120/60 0.26 0.16 20 240/50 0.17 0.13 31 240/60 0.15 0.10 23

24-50/60 24-50/60 120-50/60 120-50/60 240-50/60 240-50/60

24/50 24/60 120/50 120/60 240/50 240/60

DM COIL FOR 100RB & 240RA 1.21 0.72 17 1.02 0.52 13 0.24 0.14 17 0.20 0.10 12 0.13 0.08 20 0.11 0.06 14

12

CLASS F MOLDED

12

CLASS F MOLDED

10

CLASS F MOLDED

Ordering Information for Coils JUNCTION BOX 6” LEADS DESCRIPTION

VOLTAGE/ FREQUENCY

24V 50/60 HZ

120V 50/60 HZ

208–220/208–240 50/60 HZ 480V 50–60 HZ 120–240V 50–60 HZ

AHG 24V 50–60 HZ AMG 24V 50–60 HZ DMG 24V 50–60 HZ — — AHG 120V 50/60 HZ AMG 120V 50/60 HZ DMG 120V 50/60 HZ AHG 208–220/208–240 50–60 HZ AMG 208–220/208–240 50–60 HZ DMG 208–220/208–240 50–60 HZ — — AMG 480V 50–60 HZ

PCN

ELECTRICAL CONNECTION APPLICATION CONDUIT 18” LEADS DESCRIPTION PCN

OPEN FRAME 18” LEADS OR 1/4” SPADES DESCRIPTION PCN

057669 AMC 24V 50–60 HZ S1-057341 — S1-055129 — — — — — 057673 AMC 120V 50/60 HZ S1-057331 — 054762 — 057671 AHC 208–220/208–240 50–60 HZ S1-057342 AMC 208–220/208–240 50–60 HZ 054764 — — — — — 057527 —

057631 — — — — 057598 — — 057741 057594 — — — —

AMG 120–240V 50–60 HZ

S1-057343

AMC 120–240V 50–60 HZ

057730

AMF 120–240V 50–60 HZ

062410

AMG 277V 60 HZ — AMG 12V DC AMG 24V DC

057528 — 057521 057523

— — AMC 12V DC AMC 24V DC

— — 057596 057633

AMF 277V 60 HZ AMS 277V 60 HZ — —

057533 057714 — —

277V 60 HZ 12V DC 24V DC

VOLTAGE’ FREQUENCY 24V 50/60 HZ 24V 50/60 HZ 120V 50/60 HZ 120V 50/60 HZ 208-220/208-240 50-60 HZ 208-220/208-240 50-60 HZ 12V 12V 24V

AMF 24V 50–60 HZ S1-057539 AMF 24V 50–60 HZ 057538 RMF 24V 50–60 HZ 065677 AMS 24V 50–60 HZ 057603 RMS 24V 50–60 HZ 065680 RMF 120V 50/60 HZ 065678 AMS 120V 50/60 HZ 057349 RMS 120V 50/60 HZ 065204 AMF 208–220/208–240 50–60 HZ S1-057540 RMF 208–220/208–240 50–60 HZ 065679 AMS 208–220/208–240 50–60 HZ 057531 RMS 208–220/208–240 50–60 HZ 065681 DMS 208–220/208–240 50–60 HZ 062013 AMF 480V 50–60 HZ 057534

ELECTRICAL CONNECTION APPLICATIONS ASC2-DIN MMG - SPECIAL DC DESCRIPTION PCN DESCRIPTION PCN ASC2 24/50-60 ASC2L 24/50-60 ASC2 120/50-60 ASC2 GS-2562-1 ASC2 208-240/50-60 ASC2 GS-2562-2 — — —

062792 063542 062462 015384 062463 015383 — — —

— — — — — — MMG 12V DC MMF 12V DC MMG 24V DC

— — — — — — 063524 062972 063526

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

101


hemrichelectric.com

info@hemrichelectric.com

SOLENOID VALVES

200RB Solenoid Valves 200RB7, 200RB9 and 200RB12 cannot be converted to a bi-flo valve.) • Available in 8 orifice sizes. • Manual stem or mounting bracket adapter. Specifications: Maximum fluid temp: 250°F Maximum working pressure: 500 psig MOPD: 300 psig UL file number: MP604 CSA file number: LR44912 Note: Mounting enclosing tube more than 90° off vertical up position is not recommended.

• Solenoid actuated shut-off valves. Features: • One coil fits all valve sizes. • Extended ends for easy installation (standard). • Long-life molded coils provide water, shock, and vibration protection in coil winding. • Low pressure differential required for full Application: opening. • Pilot-operated, 2-way, normally closed Options: valves. • Connection sizes to fit your system. • Ideal for liquid, discharge or suction gas • Can be converted for bi-flo applications by refrigerant service. using conversion kit S1-056431. (Note: A Nomenclature Example: 200RB 4T3M VLC 200R

B

4

T

3

M

VLC

CONNECTION TYPE F = SAE M = MANUAL STEM VALVE DESIGN PORT SIZE CONNECTION SIZE S = ODF T = MOUNTING BRACKET ADAPTER COIL* SERIES SERIES (IN 1/16”) (IN 1/8”) P = FPT (M & T OPTIONAL) T = COPPER EXTENDED ENDS

*Note: Valves are shipped without the solenoid coils (VLC = Valve Less Coil). SOURCE 1 PART NO. STANDARD MOUNTING MANUAL VALVE STUD STEM S1-053106 S1-049609 — S1-047517 S1-047518 S1-057206 S1-059730 S1-059731 — S1-064282 S1-064645

— — — — — — — — S1-047548 — —

N/A N/A S1-047512 — — — — — — — —

VENDOR TYPE NO. 200RB 2 T 3 200RB 3 T 3 200RB 4 S 3 200RB 4 T 3 200RB 4 T 4 200RB 5 T 4 200RB 5 T 5 200RB 6 F 4 200RB 6 T 5 200RB 7 T 7 200RB 9 T 7

NOMINAL CAPACITY—TONS (KW) R404A/ R22 R407C R507

MLP

CONNECTION SIZE

R12

R134A

3/8 ODF

2.0 (7.1) 3.0 (10.6)

2.4 (8.5) 3.6 (12.7)

3.1 (11) 4.8 (17)

2.9 (10.3) 4.5 (16)

2.1 (7.4) 3.2 (11.3)

2.0 (7.1) 3.1 (11)

$ 58.37 70.32

3.6 (12.7)

4.3 (15.2)

5.6 (19.8)

5.3 (18.8)

3.7 (13.1)

3.6 (10.6)

5.3 (18.8)

6.4 (22.7)

8.2 (29)

7.8 (27.6)

5.4 (19.1)

5.3 (18.8)

100.00 100.00 118.38 118.38

6.4 (22.7)

7.7 (27.3)

10.0 (35.4)

9.5 (33.6)

6.5 (23)

6.5 (23)

3/8 ODF X 1/2 ODM 3/8 ODF

R502

1/2 ODF 5/8 ODF 1/2 SAE 5/8 ODF 7/8 ODF

10.0 (35.4) 12.1 (42.8) 15.6 (55.2) 14.8 (52.4) 10.3 (36.5) 10.1 (35.8) 19.6 (69.4) 23.6 (83.5) 30.5 (108) 29.0 (103) 20.1 (71.1) 19.8 (70.1)

134.28 141.91 224.53

Dimensional data on next page.

Ordering Information for Coils VOLTAGE/ FREQUENCY

JUNCTION BOX 6” LEADS DESCRIPTION

AHG 24V 50–60 HZ AMG 24V 50–60 HZ 24V 50–80 HZ DMG 24V 50–60 HZ — — AHG 120V 50/60 HZ 120V 50/60 HZ AMG 120V 50/60 HZ DMG 120V 50/60 HZ AHG 208–220/208–240 50–60 HZ AMG 208–220/208–240 50–60 HZ 208–220/208–240 50–60 HZ DMG 208–220/208–240 50–60 HZ — — 480V 50–60 HZ AMG 480V 50–60 HZ 120–240V 50–60 HZ AMG 120–240V 50–60 HZ AMG 277V 60 HZ 277V 60 HZ — 12V DC AMG 12V DC 24V DC AMG 24V DC

102

PCN

ELECTRICAL CONNECTION APPLICATION CONDUIT 18” LEADS DESCRIPTION PCN

057669 AMC 24V 50–60 HZ S1-057341 — S1-055129 — — — — — 057673 AMC 120V 50/60 HZ S1-057331 — 054762 — 057671 AHC 208–220/208–240 50–60 HZ S1-057342 AMC 208–220/208–240 50–60 HZ 054764 — — — — — 057527 — S1-057343 AMC 120–240V 50–60 HZ 057528 — — — 057521 AMC 12V DC 057523 AMC 24V DC

STOCKED NON STOCKED

057631 — — — — 057598 — — 057741 057594 — — — — 057730 — — 057596 057633

OPEN FRAME 18” LEADS OR 1/4” SPADES DESCRIPTION PCN AMF 24V 50–60 HZ S1-057539 AMF 24V 50–60 HZ 057538 RMF 24V 50–60 HZ 065677 AMS 24V 50–60 HZ 057603 RMS 24V 50–60 HZ 065680 RMF 120V 50/60 HZ 065678 AMS 120V 50/60 HZ 057349 RMS 120V 50/60 HZ 065204 AMF 208–220/208–240 50–60 HZ S1-057540 RMF 208–220/208–240 50–60 HZ 065679 AMS 208–220/208–240 50–60 HZ 057531 RMS 208–220/208–240 50–60 HZ 065681 DMS 208–220/208–240 50–60 HZ 062013 AMF 480V 50–60 HZ 057534 AMF 120–240V 50–60 HZ 062410 AMF 277V 60 HZ 057533 AMS 277V 60 HZ 057714 — — — —

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SOLENOID VALVES

200RB Solenoid Valves, continued 200RB2–6 Dimensional Data VALVE 200RB 4P2 200RB 4P3 200RB 4S3 200RB 4S4 200RB 4F3 200RB 5P3 200RB 5S4 200RB 5S5 200RB 5F4 200RB 5F5 200RB 6P3 200RB 6S4 200RB 6S5 200RB 6F4 200RB 6F5

PORT SIZE CONN. SIZE & STYLE

1/4

5/16

3/8

1/4 NPTF 3/8 NPTF 3/8 ODF X 1/2 ODM 1/2 ODF X 5/8 ODM 3/8 SAE (MALE FLARE) 3/8 NPTF 1/2 ODF X 5/8 ODM 5/8 ODF 1/2 SAE (MALE FLARE) 5/8 SAE (MALE FLARE) 3/8 NPTF 1/2 ODF X 5/8 ODM 5/8 ODF 1/2 SAE (MALE FLARE) 5/8 SAE (MALE FLARE)

A

B

— — 1/2 (.50) 9/16 (.56) — — 9/16 (.56) 9/16 (.56) — — — 9/16 (.56) 9/16 (.56) — —

2-3/8 (2.38) 2-3/8 (2.38) 2-3/8 (2.38) 2-3/8 (2.38) 2-15/16 (2.94) 2-3/8 (2.38) 2-3/8 (2.38) 2-3/8 (2.38) 3-5/16 (3.31) 3-9/16 (3.56) 2-3/8 (2.38) 2-3/8 (2.38) 2-3/8 (2.38) 3-5/16 (3.31) 3-9/16 (3.56)

200RB7, 9 & 12 Dimensional Data VALVE

PORT SIZE

CONN. SIZE & STYLE

200RB 7S5 5/8” ODF X 7/8” ODM 200RB 7T5 7/16” 5/8” ODF X 5/8” ODM 200RB 7T7 7/8” ODF X 7/8” ODM 200RB 9T5 5/8” ODF X 5/8” ODM 200RB 9T6 3/4” ODF X 3/4” ODF 9/16” 200RB 9T7 7/8” ODF X 7/8” ODF 200RB 9T9 1-1/8” ODF X 1-1/8 200RB 12T7 7/8” ODF X 7/8” ODF 200RB 12T9 3/4” 1-1/8” ODF X 1-1/8” ODF 200RB 12T11 1-3/8” ODF X 1-3/8” ODF

A

B

C

3 6.881 6.881 5.88 7.38 7/13 8.5 7.5 8.5 11.06

3.69 3.69 3.69 4.05 4.05 4.05 4.05 4.05 4.05 4.05

0.53 0.53 0.53 0.68 0.68 0.68 0.68 0.68 0.68 0.68

200RB Bi-Flow Conversion Kit Standard 200RB uni-directional valves can be converted to Bi-Flow operation by replacing the internal parts with the components in kit S1056431. Unlike the standard valve which per-

mits flow in one direction only when energized, the Bi-Flow version allows the valve to flow in either direction, depending on differential pressures, when energized. If the valve is not ener-

SOURCE 1 PART NO. S1-056431

gized when flowing in the reverse direction, valve “flutter” will occur. Also, with the valve deenergized, a higher downstream pressure than upstream (back-flow) will force the valve open.

VENDOR TYPE NO.

DESCRIPTION

KS30293

200RB BI-FLOW CONVERSION KIT

MLP

NOTE: A 200RB7, 200RB9 and 200RB12 cannot be converted to a Bi-Flow valve.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

103


hemrichelectric.com

info@hemrichelectric.com

SOLENOID VALVES

240RA Solenoid Valves • Mounting stud models can be field converted to manual lift stem. Options: • Connection sizes to fit your system. • Manual stem or mounting bracket adapter. Specifications: Maximum fluid temp: 250°F Maximum working pressure: 500 psig MOPD: 300 psig UL file number: MP604 CSA file number: LR44912 Note: Mounting enclosing tube more than 90° off vertical up position is not recommended.

• Solenoid actuated shut-off valve. Features: • One coil fits all valve sizes. • Can be brazed into the line without disassembly. • Reinforced Teflon® (PTFE) diaphragm with woven fiberglass for superior control. • Durable, stainless enclosing tube. • Extended ends for easy installation (standard). Application: • Long-life molded coils provide water, shock, • 2-way, normally closed diaphragm valves. and vibration protection in coil winding. • Ideal for liquid, suction and hot gas service. • Low pressure differential required for full opening. Nomenclature Example: 240RA 8T5M VLC 240R

A

8

T

5

M

VLC

VALVE DESIGN PORT SIZE CONNECTION TYPE CONNECTION SIZE M = MANUAL STEM (OPTIONAL) COIL* SERIES SERIES (IN 1/16”) T = COPPER EXTENDED ENDS (IN 1/8”) T = MOUNTING BRACKET ADAPTER (OPTIONAL)

*Note: Valves are shipped without the solenoid coils (VLC = Valve Less Coil).

STANDARD VALVE

SOURCE 1 PART NO. MOUNTING MANUAL STUD STEM

VENDOR TYPE NO.

CONNECTION SIZE

S1-043204

240RA 9 T 7

7/8 ODF

— —

— —

S1-046637 S1-046638

240RA 20 T 13 240RA 20 T 17

1-5/8 ODF 2-1/8 ODF

NOMINAL LIQUID CAPACITY—TONS (KW) R404A/ R12 R134A R22 R407C R507 R502 19.6 (69.4) 58.8 (208)

23.6 (83.5) 70.9 (251)

30.5 (108) 95.4 (338)

29.0 (103) 90.8 (321)

21.0 (71.1) 65.7 (230)

19.8 (70.1) 62.0 (219)

MLP $ 235.32 804.68 1054.03

NOTE: FOR VALVE DIMENSIONS SEE NEXT PAGE

104

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SOLENOID VALVES

240RA Solenoid Valves, continued

240RA Dimensional Data (inches) VALVE 240RA8T5-T 240RA8T5-M 240RA8T7-T 240RA8T7-M 240RA9T5-T 240RA9T5-M 240RA9T7-T 240RA9T7-M 240RA9T9-T 240RA9T9-M 240RA12T7-T 240RA12T7-M 240RA12T9-T 240RA12T9-M 240RA16T9-T 240RA16T9-M 240RA16T11-T 240RA16T11-M 240RA20T11-T 240RA20T11-M 240RA20T13-T 240RA20T13-M 240RA20T17-T 240RA20T17-M

PORT SIZE 1/2 (.50)

CONN. SIZE 5/8 ODF (.63) 7/8 ODF (.88) 5/8 ODF (.63)

9/16 (.56)

7/8 ODF (.88) 1-1/8 ODF (1.13)

3/4 (.75)

1 (1.00)

7/8 ODF (.88) 1-1/8 ODF (1.13) 1-1/8 ODF (1.13) 1-3/8 ODF (1.38) 1-3/8 ODF (1.38)

1-1/4 (1.25)

1-5/8 ODF (1.63) 2-1/8 ODF (2.13)

A

B

4-51/64 (4.80) 5-39/64 (5.61) 4-51/64 (4.80) 5-39/64 (5.61) 5-5/64 (5.08) 5-57/64 (5.89) 5-5/64 (5.08) 5-9/16 (5.56) 5-5/64 (5.08) 5-57/64 (5.89) 5-5/64 (5.08) 5-57/64 (5.89) 5-5/64 (5.08) 5-57/64 (5.89) 5-11/32 (5.34) 6-1/4 (6.25) 5-11/32 (5.34) 6-1/4 (6.25) 5-29/64 (5.45) 6-51/64 (6.80) 5-29/64 (5.45) 6-15/32 (6.47) 5-29/64 (5.45) 6-15/32 (6.47)

1-11/32 (1.34) 2-5/32 (2.16) 1-11/32 (1.34) 2-5/32 (2.16) 1-1/2 (1.50) 2-5/16 (2.31) 1-1/2 (1.50) 2-5/64 (2.08) 1-1/2 (1.50) 2-5/16 (2.31) 1-1/2 (1.50) 2-5/16 (2.31) 1-1/2 (1.50) 2-5/16 (2.31) 1-21/32 (1.66) 2-9/16 (2.56) 1-21/32 (1.66) 2-9/16 (2.56) 1-5/16 (1.31) 2-21/32 (2.66) 1-5/16 (1.31) 2-21/64 (2.33) 1-5/16 (1.31) 2-21/64 (2.33)

C

D

3-9/32 (3.28)

6-7/8 (6.88)

3-13/32 (3.41)

7-1/8 (7.13)

3-13/64 (3.20)

6-7/8 (6.88)

3-21/64 (3.33)

7-1/8 (7.13)

4-1/64 (4.02)

8-1/2 (8.50)

3-33/64 (3.52)

7-1/2 (7.50)

4-1/64 (4.02)

8-1/2 (8.50)

4-1/4 (4.25)

9-1/16 (9.06)

5-1/4 (5.25)

11-1/16 (11.06)

5-7/64 (5.11)

10-13/16 (10.81)

5-57/64 (5.89)

12-3/8 (12.38)

6-37/64 (6.58)

13-3/4 (13.75)

E

F

G

1-21/64 (1.33) 1-23/64 (1.83) 1-21/64 (1.33) 1-23/64 (1.83) 1-31/64 (1.48) 1-33/64 (1.52) 1-31/64 (1.48) 1-33/64 (1.52) 1-31/64 (1.48) 1-33/64 (1.52) 1-31/64 (1.48) 1-33/64 (1.52) 1-31/64 (1.48) 1-33/64 (1.52) 1-3/8 (1.38) 1-13/32 (1.41) 1-3/8 (1.38) 1-13/32 (1.41) — — — — — —

27/64 (.42) 29/64 (.45) 27/64 (.42) 29/64 (.45) 37/64 (.58) 39/64 (.61) 37/64 (.58) 39/64 (.61) 37/64 (.58) 39/64 (.61) 37/64 (.58) 39/64 (.61) 37/64 (.58) 39/64 (.61) 1 (1.00) 1-1/32 (1.03) 1 (1.00) 1-1/32 (1.03) — — — — — —

1/2 (.50) 1/2 (.50) 3/4 (.75) 3/4 (.75) 1/2 (.50) 1/2 (.50) 3/4 (.75) 3/4 (.75) 29/32 (.91) 29/32 (.91) 3/4 (.75) 3/4 (.75) 29/32 (.91) 29/32 (.91) 29/32 (.91) 29/32 (.91) 31/32 (.97) 31/32 (.97) 31/32 (.97) 31/32 (.97) 1-3/32 (1.09) 1-3/32 (1.09) 1-11/32 (1.34) 1-11/32 (1.34)

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

H

2-1/16 (2.06)

— —

3-7/16 (3.44)

4-1/16 (4.06)

105


hemrichelectric.com

info@hemrichelectric.com

SPORLAN SOLENOID VALVES

“ME” Series Solenoid Valves Features: • With manual lift stem • Solenoid Valve Coil not included • Normally closed • Extended connections • Application: • Mounted vertical, horizontal or side • Installation without disassembly

SOURCE 1 PART NO.

SPORLAN PART NO.

CONNECTION SIZE & TYPE

PORT SIZE

NOMINAL CAPACITY @ 2 PSI (TONS) (R-22)

DIM A

SHIPPING WEIGHT (LBS.)

USE COIL KIT

MLP

S1-52636263000 S1-52636264000 S1-52636265000 S1-52636266000 S1-52636267000 S1-52636268000 S1-52636269000 S1-52636270000 S1-52636271000 S1-52636272000

ME6S130 ME6S140 ME9S230 ME9S240 ME10S240 ME10S250 ME14S250 ME19S250 ME19S270 ME25S270

3/8 ODF 1/2 ODF 3/8 ODF 1/2 ODF 1/2 ODF 5/8 ODF 5/8 ODF 5/8 ODF 7/8 ODF 7/8 ODF

.188 .188 .281 .281 .313 .313 .438 .594 .594 .781

4.0 4.0 6.6 6.6 9.1 9.1 12.9 17.2 19.8 33.7

4.63 5.00 4.63 5.00 5.00 6.50 6.88 6.88 7.13 7.50

1.25 1.25 1.75 1.75 2.00 2.00 2.25 3.75 3.75 6.00

MKC-1 MKC-1 MKC-2 MKC-2 MKC-2 MKC-2 MKC-2 MKC-2 MKC-2 MKC-2

$122.31 122.31 156.78 148.57 164.62 172.15 181.05 275.67 275.42 385.92

“E” Series Solenoid Valves • Less coil

Features: • Solenoid Valve Coil not included • Extended connections • Normally closed Application: • Mounted vertical, horizontal, or side • Installation without disassembly

SOURCE 1 PART NO. S1-52636262000

SPORLAN PART NO.

CONNECTION SIZE & TYPE

PORT SIZE

NOMINAL CAPACITY @ 2 PSI (TONS) (R-22)

DIM A

DIM B

DIM C

DIM D

SHIPPING WEIGHT (LBS.)

USE COIL KIT

MLP

E5S130

3/8 ODF X 3/8 ODF

.150

2.3

4.56

0.53

2.29

0.22

1.25

MKC-1

$76.47

Replacement Solenoid Valve Coil Kit MKC-1 & MKC-2 Features: •Designed for continuous duty •Supplied with junction box •Electrical specifications listed on coil & nameplate •Blue lead wire

SOURCE 1 PART NO. S1-52636276000 S1-52636277000 S1-52636278000 S1-52636279000

VA

SPORLAN MODEL NO.

VOLTS / HZ

WATTS

HOLDING

INRUSH

MLP

MKC-1 24/50-60 JAM * MKC-1 120-208-240/50-60 JAM * MKC-2 24/50-60 JAM * MKC-2 120-208-240/50-60 JAM *

24 VOLT 50/60 HZ 120/208/240 VOLT 50/60 HZ 24 VOLT 50/60 HZ 120/208/240 VOLT 50/60 HZ

10 10 15 15

.63 .14/.09 1.4 .26/.13

1.9 .39/.19 3.1 .60/.31

$55.59 73.82 65.17 81.13

* J = Junction Box, A = 1/32" Insulation, M = Blue Lead Wire.

106

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

REFRIGERATION BALL VALVES

ABV Refrigeration Ball Valve

Applications: Isolate suction, discharge, and liquid line pipework during maintenance shutdown periods.

Features: • Forged brass body. • Hermetic design • Compatible with new refrigerants/lubricants. • Full internal ports (Reduced ports on 2-5/8” and 3-1/8” models.) • Bi-directional flow characteristics • Valve stem cap retained by strap attached to main body • Integrated access port available on all sizes.

Specifications: Welded Body: Forged Brass Extension Stubs: 100% Copper Connections Maximum working pressure: 500 psig Not for use with R-123 Fluid temperature range: +300°F to –40°F UL File Number: SA5312 CSA File Number: LR701890

Nomenclature Example: ABV 5A A

BV

5

A

CONNECTION SIZE ACCESS VALVE ALCO BALL VALVE (IN 1/8”) (OPTIONAL)

SOURCE 1 PART NO. WITHOUT WITH ACCESS VALVE ACCESS VALVE S1-064383 S1-062104 S1-062105 S1-062106 S1-064385 S1-062107 S1-062108 S1-062109 — —

DIMENSIONS (INCHES) VENDOR TYPE NO. VALVE

PORT SIZE

CONNECTION SIZE

A

B

MLP W/O

MLP WITH

ABV 2 ABV 3 ABV 4 ABV 5 ABV 6 ABV 7 ABV 9 ABV 11 ABV 13 ABV 17

1/2 1/2 1/2 1/2 3/4 3/4 1 1-1/4 1-1/2 2

1/4 ODF 3/8 ODF 1/2 ODF 5/8 ODF 3/4 ODF 7/8 ODF 1-1/8 ODF 1-3/8 ODF 1-5/8 ODF 2-1/8 ODF

5.47 5.47 6.35 6.35 7.42 7.42 9.11 9.97 10.98 11.72

2.55 2.55 2.97 2.97 3.49 3.49 4.47 4.84 5.38 5.77

$ 47.58 47.58 47.58 53.18 67.87 71.05 102.62 167.70 N/A N/A

N/A $ 56.16 56.16 60.80 75.99 77.07 111.16 N/A 196.59 301.41

— S1-062114 S1-062115 S1-062116 S1-064386 S1-062117 S1-062118 — S1-062120 S1-062121

* Reduced port

Valve Core, Core Remover & Valve Core Tool

AF2000 SOURCE 1 PART NO. S1-AF2000 S1-AF2100 S1-AF2200

AF2100

AF2200

DESCRIPTION

PKG. QTY.

MLP PER EACH *

1/4" SAE GASKET SEAL CAP W/CORE REMOVER 1/4" VALVE CORE 1/4" VALVE CORE TOOL

10 5 1

$0.79 0.79 2.33

* Sold by the package only

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

107


hemrichelectric.com

info@hemrichelectric.com

Relay/Overload Combination Features • Built in Mounting Clip • Mounts in any Position • Prewired for Fast and Simple Installation • Can Be Used with Either A Capacitor or Non-Capacitor Applications Specifications • MA-IC13 1/4 & 1/3 HP 120V 50/60 HZ • MA-IC15 1/8, 1/6, 1/5 HP 120V 50/60 HZ

SOURCE 1 PART NO. S1-MA-IC13 S1-MA-IC15

DESCRIPTION

MLP

RELAY OVERLOAD RELAY OVERLOAD

$14.45 14.45

Copper Tube Extensions

COPPER EXTENSION TUBE 2" LONG SOURCE 1 PART NO. S1-AF1000 S1-AF1100 S1-AF1200 S1-AF1300 S1-AF1400 S1-AF1500 S1-AF1600 S1-AF1000-50 S1-AF1100-50 S1-AF1200-50 S1-AF1300-50 S1-AF1400-50 S1-AF1500-50 S1-AF1600-50

DESCRIPTION

PKG. QTY.

MLP PER EACH *

1/8" OD TUBE EXTENSION 3/16" OD TUBE EXTENSION 1/4" OD TUBE EXTENSION 5/16" OD TUBE EXTENSION 3/8" OD TUBE EXTENSION MULTI OD TUBE EXTENSION MULTI OD TUBE EXTENSION 1/8" OD TUBE EXTENSION 3/16" OD TUBE EXTENSION 1/4" OD TUBE EXTENSION 5/16" OD TUBE EXTENSION 3/8" OD TUBE EXTENSION MULTI OD TUBE EXTENSION MULTI OD TUBE EXTENSION

5 5 5 5 5 3 3 50 50 50 50 50 50 50

$1.79 1.96 1.91 2.78 3.20 4.73 4.73 2.33 2.33 2.33 2.66 2.66 4.40 4.40

* Sold by the package only

Source 1 Refrigerant Orifice Kit SOURCE 1 PART NO. S1-37313266000

MLP $303.75

This kit features a lightweight translucent box 8-1/4" x 4-1/2" x 1-3/8" deep. The kit has 18 individual compartments. Each compartment contains five each of the orifices listed below. To order additional orifices use part number listed below.

108

SOURCE 1 PART NO.

SIZE

MLP

SOURCE 1 PART NO.

SIZE

MLP

S1-02919387014 S1-02919387009 S1-02919387010 S1-02919387003 S1-02919387015 S1-02919387011 S1-02919387016 S1-02919387004 S1-02919387029

.055 .057 .059 .061 .063 .065 .067 .069 .071

$4.12 4.12 4.12 3.60 4.12 3.38 4.12 3.60 2.88

S1-02919387005 S1-02919387017 S1-02919387006 S1-02919387012 S1-02919387019 S1-02919387007 S1-02919387013 S1-02919387022 S1-02919387008

.073 .075 .078 .081 .084 .087 .090 .093 .096

$4.12 4.12 4.12 4.16 2.88 4.12 4.12 2.88 4.12

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com GAS HEATING CONTROLS & COMPONENTS

WHITE RODGERS GAS VALVES

36H Series Universal Fast Open High Capacity Gas Valves 36H valves are used for proven pilot applications, and can replace more than 93 valves in the 36C68/36C76 series. Improvements over the 36C series include: field convertible from Natural to LP, independently field adjustable two-stage regulators and electric on/off switch. Features: • 320K BTU at 1” pressure drop versus 280K BTU at 1” for the 36C series • Diaphragm size increased 15% over 36C series resulting in improved regulation set point stability • Quiet design, DC rectified • Independently adjustable high/low two stage • Direct ignition or proven pilot SOURCE 1 PART NO.

S1-36H32-423

S1-36H64-463

STAGES

SINGLE

TWO

• • • •

24 volt, 50/60 Hz 0.75” x 0.75”; 0.25” press tap in and out 50k–400k BTU range of regulation Straight through design

REPLACES 36C68-200 36C68-202 36C68-205 36C68-209 36C68-212 36C68-217 36C68-218 36C68-243 36C68-261 36C68-262 36C68-266 36C68-301 1RC52 36C76-205 36C76-210 36C76-214 36C76-225 36C76-227

36C68-303 36C68-324 36C68-325 36C68-326 36C68-327 36C68-330 36C68-400 36C68-403 36C68-404 36C68-405 36C68-415 36C68-418 36C76-230 36C76-401 36C76-406 36C76-407 36C76-408 36C76-411

MLP

36C68-419 36C68-423 36C68-434 36C68-441 36C68-442 36C68-448 36C68-452 36C68-457 36C68-464 36C68-472 36C68-473 36C68-477 36C76-412 36C76-417 36C76-420 36C76-445 36C76-459 36C76-463

36C68-601 36C68-602 36C68-606 36C68-607 36C68-806 700-418 700-420 V845A1109 VR8304M4507 VR8345M4302 36C76-467 36D13-208 36D13-405 36D13-208 36H64-463 700-413

$210.75

461.29

36C Replacement Gas Controls

Features • Valve may be mounted in any position, except upside down. • Both main valve seat and line-interrupter seal with line pressure, assuring positive gas seal-off.

SOURCE 1 PART NO. S1-36C03-300 S1-36C03-400 S1-36C03-333 S1-36C03-433 S1-36C03U-333

• Inlet screen, pilot gas filter and top operated main valve provide maximum protection against chips and dirt. • Gas cock knob, pilot adjust screw and regulator adjustment are on top of control. • Thermocouple connection on models with line interrupter and combination tab/screw terminals on 24 VAC models. • Easy grip pipe boss simplifies installation. Built-in regulator system provides constant outlet pressure throughout entire usable capacity of valve, regardless of inlet pressure fluctuations. • For use with all gases. (All models include LP Conversion kits.) • Model 36C03 (24V) is for use with thermocouple (H06E Series, p. 118).

COIL VOLTAGE

INLETOUTLET SIZE

CAPACITY A.G.A. STANDARD GAS*

GAS

24 VAC, 60 HZ 24 VAC, 60 HZ 24 VAC, 60 HZ 24 VAC, 60 HZ 750 MV

1/2 X 3/4 3/4 X 3/4 1/2 X 3/4 3/4 X 3/4 1/2 X 3/4

230,000 280,000 230,000 280,000 230,000

NAT NAT NAT NAT NAT

LP CONVERSION KIT

REDUCER BUSHING KIT

YES

YES

• Model 36C03U is for use with 750 millivolt power generator (S1-G01A-332, p. 118) and may be used with 250 millivolt system if nonanticipated room thermostat is used. Must be used in vented application. Specifications Regulator Setting: Natural gas, 3-1/2” W.C. Regulator Adjustment Range: 2-1/2” to 5” W.C. Ambient Operating Range: –40 to +175° F (–40 to +79° C) Maximum Pressure Rating: 1/2 PSI (14.0” W.C.) Pilot Gas Connection: 1/4” compression fitting furnished. Pressure Tap: 1/8” NPT. Body Pattern: Straight through.

SIDE TAPS NO NO YES YES YES

LINE INTERRUPTER

YES

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

INLET PRESSURE TAP

YES

MLP $136.13 159.03 136.59 160.32 204.13

109


hemrichelectric.com

info@hemrichelectric.com

WHITE RODGERS GAS VALVES

36C Step-Opening Complete Gas Valves With Natural/LP Gas Selector

24 VAC thermocouple-operated combination gas valve provides definite regulated step for smoother ignition of main burner.

SOURCE 1 PART NO. S1-36C12-310

Features: • Step-opening main operator; valve initially opens to approximately 20% of rated flow for a minimum of two seconds, then fully opens • Gas selector (two positions: UP for natural, DOWN for LP) changes regulator setting from one gas to the other • Both main seat and flow-interrupter seal with line pressure, assuring positive gas seal-off • Inlet screen, pilot gas filter and top-operated main valve provide maximum protection against dirt and chips • Multipoise mounting (except upside-down) • Easily accessible pilot-gas and pressure taps, combination tab-screw terminals and easy grip pipe boss simplify installation

OPEN FEATURE

GAS

1" P.D. CAP

IN NPTI

STEP 0.8” W.C. STEP 2.0” W.C.

NAT LP

230,000 372,600

1/2 1/2

PIPE SIZE OUT NPTI

• A.G.A. design certified and C.G.A. Certified Specifications: Electrical rating: 0.23 amps Regulator setting: Natural gas, 3.5" W.C., LP gas, 11.0" W.C. Ambient operating range: –40° to +175° F (–40° to +79° C) Maximum pressure rating: 1/2 PSI (14.0" W.C.) Pilot gas connection: 1/4" compression fitting furnished Pressure tap: 1/8" NPT Swing radius: 4.5"

PIPE IN DIM

ELEC CONN

MLP

3.94 3.94

3 SCREW/TABS 3 SCREW/TABS

$389.75 389.75

3/4 3/4

36E Redundant Gas Valve The 36E combination gas manifold is a compact multifunction valve designed to meet the requirements for use with intermittent ignition systems including proven pilot, direct spark ignition and hot surface ignition. Along with its compact size, all valve adjustments and features, as well as the system interface wiring panel, have been designed on the top surface of the control for simplified servicing and easy accessibility. Features: • Poppet style manual valve (capable of withstanding high inlet pressures) • Conical inlet and outlet screens protected from pipe damage • Keyed wiring • Direct acting solenoid valve with high sealing force • Controlled gasket clinch between castings to withstand high inlet pressures • Tamper-resistant screws SOURCE 1 PART NO. S1-36E37-215 S1-36E38-301 S1-36E38-302 S1-36E29-202 S1-36F24-206 S1-36E29-101

OPEN FEATURE

GAS

1" P.D. CAP

IN NPTI

.006 SLOW STEP 1.2” W.C. STEP 2.5” W.C. FAST .008 SLOW FAST

NAT NAT LP CONV † NAT CONV †

140,000 140,000 226,800 120,000 140,000 120,000

1/2 1/2 1/2 1/2 1/2 1/2

• May be mounted horizontal, vertical and 90° from horizontal • All valves have pilot filter, adjustable pilot pressure and manual shut-off valve • A.G.A. design certified and C.G.A. Certified • Side taps • Quick Connect electrical connections Specifications: Electrical rating: 0.30 amps Coil Voltage: 24 VAC, 60 Hz Regulator adjustment range: Natural gas, 2.5" to 5.0" W.C.; LP gas, 7.0" to 12.0" W.C. Maximum pressure rating: 1/2 PSI (14.0" W.C.) Swing radius: 3-9/16" Ambient operating range: –40° to +175° F (–40° to +79° C) NOTE: All natural gas valves include an LP Conversion Kit. PIPE SIZE OUT NPTI 1/2 3/4 3/4 1/2 1/2 3/8

PIPE IN DIM

MLP

4.78 4.78 4.78 4.78 4.78 4.78

$ 92.65 259.97 220.08 73.07 64.24 66.09

† Non adjustable, convertible regulator set for natural

110

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

WHITE RODGERS GAS VALVES

25M Gas Valves The 25M Series gas valve is a compact, multifunction control, with direct acting regulator ideal for use in pilot valve applications, thru the wall heaters, RV heaters, or high efficiency equipment. Because of the valve’s unique design, the operating solenoids and valves may be configured differently to satisfy any application requirement Special Features: • Compact size: 3-13/32" x 2-1/2" x 2-19/32" • Field adjustable regulator

SOURCE 1 PART NO.

• Operating coils replaceable without interrupting gas system • Outlet pressure tap • Offset straight thru outlet • Ambient rating of -40° to 175° F (single and dual solenoid versions) • Multifunction Specifications: Regulator adjustment range: Natural gas, 2.8" to 4.0" W.C.

OPEN FEATURE

GAS

AMPS @ 12 VDC STG 1

REGULATOR SETTING STG 1

1" P.D. CAP

FAST

NAT

0.48

3.5

40,000

S1-25M12V-701

Range of Regulation: 5000 to 55,000 BTU/hr (natural) Maximum pressure: 1/2 PSI Mounting: horizontal, vertical, or 90° of horizontal Coil terminations: (2) .187 terminals (0.020 thick) Coil voltage: 12 V.D.C.

PIPE SIZE IN NPTI OUT NPTI 3/8

PIPE IN DIM

ELEC CONN

MLP

3.41

4 QCS

$105.11

3/8

Conversion Kits for White-Rodgers Gas Valves SOURCE 1 PART NO. S1-F92-0656 S1-F92-0659

TYPE OF CONVERSION

USED WITH VALVE TYPE

MLP

PROPANE TO NATURAL NATURAL TO PROPANE

36C & 36E VALVES W/REGULATOR RANGE OF 2.5" TO 5.0" W.C. 36C & 36E VALVES W/REGULATOR RANGE OF 7.5´ TO 12.0" W.C.

$ 9.83 11.78

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

111


hemrichelectric.com

info@hemrichelectric.com

WHITE RODGERS GAS VALVES

36E Redundant Gas Valve The 36E Combination Gas Manifold is a compact multifunction valve designed to meet the requirements for use with all types of intermittent ignition systems (cycle pilot, proven pilot, direct spark ignition and hot surface ignition). Along with its compact size, all valve adjustments and features, as well as the system interface wiring panel, have been designed on the top surface of the control for simplified servicing and easy accessibility. The 36E gas valve is designed to meet today’s requirements for capacity and size. Features: • Poppet style manual valve (capable of withstanding high inlet pressures). • Conical inlet and outlet screens protected from pipe damage. • Keyed wiring. • Direct acting solenoid valve with high sealing force. • Controlled gasket clinch between castings to withstand high inlet pressures. • Tamper-resistant screws.

SOURCE 1 PART NO.

COIL VOLTAGE

INLETOUTLET SIZE

CAPACITY A.G.A. STANDARD GAS

TOTAL REG. CAPACITY

1/2” X 3/4” S1-36E52-214 1/2” X 3/4”

S1-36E93-304

1/2” X 3/4” 24 VAC 60 HZ 1/2” X 1/2”

S1-36E96-250

1/2” X 1/2”

S1-36E98-304

1/2” X 3/4”

STEP OPENING

FAST OPEN, NO STEP 210,000

5 SPADE TERMINALS

GAS

FAST OPEN, NO STEP SLOW OPEN, NO STEP FAST OPEN, NO STEP

F115-0087

140,000

S1-36E96-314

REGULATOR SETTING

3 SPADE TERMINALS 1/4”

S1-36E36-304*

S1-36E86-302

ELEC CONN

• May be mounted horizontal, vertical and 90° from horizontal. • All valves have pilot filter, adjustable pilot pressure and manual shut-off valve. • A.G.A. And C.G.A. Design certified. Specifications: Electrical Rating: 0.54 amps. Regulator Adjustment Range: Natural gas, 2-1/2 to 5.0” W.C.; LP gas, 7.0 to 12.0” W.C. Maximum Pressure Rating: 1/2 PSI (14.0” W.C.) Swing Radius: 3-9/16”. Ambient Operating Range: –40 to +175° F (–40 to +79° C)

3-1/2” W.C.

NAT

ELECTRONICALLY OPERATED LOW FIRE 1-6” W.C. 2 STAGE FAST OPEN

3 SPADE TERMINALS 1/4”

SLOW OPEN, NAT NO STEP & LP

SYSTEM USAGE

REDUCER BUSHING KIT

SIDE TAPS

MLP

YES

YES

$196.38

YES

NO

180.21

YES

YES

372.47

NO

NO

227.62

YES

NO

340.16

NO

NO

120.13

YES

NO

182.00

PROVEN PILOT, HSI AND DSI CYCLE PILOT PROVEN PILOT WITH PRESSURE SWITCH PROVEN PILOT, HSI AND DSI PROVEN PILOT, HSI AND DSI PROVEN PILOT, HSI, DSI

* Pilot fittings included with valves. Cross Reference SOURCE 1 PART NO. S1-36E98-304

S1-36E36-304

S1-36C68-423 S1-36H32-423 S1-36H64-463

112

REPLACES HONEYWELL: VR8204H 1006, VR8204H1014, VR8205H 1003, VR8205H 1011, VR8205K 1157, VR8304H 3505 ROBERTSHAW: 720-050, 720-052 HONEYWELL: VR8204A 2076, VR8205A 2024, V8185A 1001, V8185A 1019, V8185A 1035, V8185B 1009, V8185B 1017, V8247A 1000, V8247B 1005, V845A 1018, V845A 1026, V845A 1034, V845A 1133, VR8205A 2008, VR8205A 2016, VR8450A 2000, VR8450A 2109, VR8450A 2117, VR8450M 2023, VR8450M 2024, VR8450R 6003, VR845M 1013, VR8204A 2258, VR8204A 2266, VR8204M 1091, VR8204A 2001, VR8204A 2027, VR8204A 2035, VR8204A 2043, VR8204A 2050, VR8204A 2068, VR8204A 2092, VR8204A 2126, VR8204A 2134, VR8204A 2142, VR8204A 2167, VR8204A 2175, VR8204A 2001, VR8440A 2019, VR8440A 2050, VR8440A 2076, VR8440A 2084, VR8440A 2092, VR8440A 2100, VR8440A 2118, VR8440A 2134, VR8440A 2142, VR8440M 1000, VR8440M 2008, VR8440M 2016, VR8440M 2024, VR8440M 2032, VR8440M 2040, VR8440M 2057, VR8440M 2065, VR8440M 2073, VR8440M 2081, VR844A 1002, VR8440M 2099, VR844A 1085, VR844M 1006, VR844M 1014, VR844M 1063, VR844M 1162, VR844M 1170, VR844M 1188, VR844M 1196, VR844M 1220, VR844M 1246, VR844M 1287, VR844M 1295, VR844N 1003, VR844N 1005 ROBERTSHAW: 700-070, 700-072 HONEYWELL: V845A 1109, VR8345 M4302 ROBERTSHAW: 700-420 WHITE-RODGERS: 36C68-423 WHITE-RODGERS: 36C76-406, 36C76-420, 36C76-463

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL GAS VALVES

V800 Standing Pilot Gas Valve

Used on gas fired standing pilot appliances with 30 mV thermocouple. These gas controls include a manual gas valve, safety shutoff, single millivoltage automatic operator, and pressure regulator, pilot gas filter and flow adjustment, pressure tapping, and thermocouple connector. V800 is used on 24V systems.

Features: • Include pilot flow adjustment screw. • Easy to install, adjust and service; all adjustments and connections are accessible from top of control. • Add separate energy cutoff (ECO) where codes call for dual safety shutoff. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence. • ECO connector for V800 models. Part No. 392451-1. Specifications: Type: Single Stage Ignition Type: Standing Pilot Type of Gas: Natural or LP Body Pattern: Straight-through, multi-tapped with 1/2" right and left outlets plugged Pressure Ratings (psi): 1/2 psi Pressure Ratings (kPa): 3.5 kPa

Pilot Gas Outlet: Compression fitting for 1/4” OD tubing Pressure Tapping: 1/8” NPT with plug Electrical Ratings: 24 VAC Frequency: 60 Hz Anticipator Setting: .2 A Temperature Range (F): 32°F to 175°F Temperature Range (C): 0°C to 79°C Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. Dimensions (in.): 4-3/4”H x 4-1/16”W x 3-3/16”D Dimensions (mm): 121 mm H x 103 mm W x 81 mm D Approvals: American Gas Association IAS AGA Design Certified; File No. L2025003, CGA Design Certified; File No. L2025003, UL Component Recognized; Underwriters Laboratories Inc UL Component Recognized.

l

INLET/ OUTLET SIZE

SOURCE 1 PART NO.

PRESSURE REGULATOR SETTING

OPENING CHARACTERISTICS

CAPACITY @ 1 IN. P.D.

3.5 IN. WC

0.87 KPA

3.5 IN. WC

0.87 KPA

ONE 1/2 IN. X 3/4 IN. REDUCER BUSHING/ADAPTER

234.73

TWO 3/4 X 1/2 IN; ONE 1/2 X 3/8 IN. REDUCER BUSHINGS/ADAPTERS

581.08

S1-V800A1070

3/4 IN. X 3/4 IN.

STANDARD

335,000 BTU/HR

S1-V800A1088

1/2 IN. X 3/4 IN.

STANDARD

250,000 BTU/HR

PSI

KPA

ELECTRICAL CONNECTIONS

ACCESSORIES INCLUDED ONE 3/4 X 1/2 IN. REDUCER BUSHINGS/ADAPTERS TWO 3/4 IN. X 1/2 IN.; ONE 1/2 IN. X 3/8 IN. REDUCER BUSHINGS/ADAPTERS

S1-V800A1476

1/2 IN. X 3/4 IN.

STANDARD

250,000 BTU/HR

3.5 IN. WC

0.87 KPA

COMBINATION SCREW AND 1/4 IN. MALE QUICK CONNECTS

S1-V800C1052

3/4 IN. X 3/4 IN.

STEP OPENING

335,000 BTU/HR

FULL RATE: 3.5 IN. WC; STEP SETTING: 0.9 IN. WC

FULL RATE: 0.87 KPA; STEP SETTING: 0.22 KPA

COMBINATION SCREW AND 1/4 IN. MALE QUICK CONNECTS

MLP $247.94 311.35

VR8200 Continuous Pilot Dual Automatic Combination Gas Valves

Combination gas controls for use in 24 VAC, gas-fired, standing pilot appliances with capacities from 20 to 200 cfh. Both include: 1/2” x 3/8” reducer bushing; 39369014 bag assembly—3/4” straight flange with O ring, screws and wrench; Q340 (39”) thermocouple with adapters; and 393691 Natural to LP gas conversion kit. • Control includes safety shutoff, a manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Compact size. SOURCE 1 PART NO. S1-VR8200A2132

GAS TYPE NAT

S1-VR8200A2124

• Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. • Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. • VR8200 controls replace the following Honeywell and competitive combination gas controls for applications requiring a minimum capacity of 20 cfh and a maximum capacity of 200 cfh. — Honeywell V800A and VR800A models — White Rodgers 36C03/01 series — Robertshaw 7000BER (700-400) series — Robertshaw 7200BER (720-400) series — ITT B57 and B59 series — Essex SX242N

AMPS @ 24 VAC/60 HZ MAIN 0.5

PRESSURE SETTING MAIN 3.5

Approval Bodies: American Gas Association Design certified: File No. L2025006. Canadian Gas Association Design certified: File No. L2025006. Underwriters Laboratories Inc. component recognized: File No. MH5323. Lite-Rite (Off-Pilot-On) lighting sequence. Mounting: 0° to 90° in any direction from the upright position of gas control knob, including vertically. Body Pattern: Straight-through with 1/2" inlets and outlets. Pilot Gas Outlet: Compression fitting for 1/4” OD tubing. Pressure Tapping: 1/8" NPT with plug. Pressure Rating: 1/2 PSI [3.5 kPa] inlet pressure. Ambient Temperature Range: VR8200A: 0°F to 175°F [-18°C to +79°C]. Electrical Data: Supply Voltage: 24 VAC, 60 Hz. Wiring Connections: Combination screw and 1/4" male quick-connects. Thermostat Heat Anticipator Setting: 0.5 A.

CAPACITY 130,000 BTU/HR; 20,000 BTU/HR MINIMUM 130,000

INLET NPTI

OUTLET NPTI

PIPE IN DIM

1/2

1/2

4.125

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

MLP $145.71 161.74

113


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL GAS VALVES

VR8204 Intermittent Pilot Dual Automatic Combination Gas Valves • Provide two automatic valves. • Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. • Diaphragm operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit. • All adjustments and wiring connections are accessible from top of control. • VR8204 controls replace the following Honeywell and competitive combination gas controls for applications requiring a minimum capacity of 20 cfh and a maximum capacity of 200 cfh. — Honeywell VR8440 — White Rodgers 36E36/38 — Robertshaw 7100DER (700-070) Approval Bodies: American Gas Association Design certified: File No. L2025006.

Combination gas controls for use in 24 VAC, gas-fired intermittent pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Use with S86F,H; S8600F,H and S8610 control modules. • Compact size.

SOURCE 1 PART NO. S1-VR8204A2027 S1-VR8204C1019 S1-VR8204C1050 S1-VR8204M1026

GAS TYPE

AMPS @ 24 VAC/60 HZ MAIN

NAT NAT LP NAT

0.5 0.5 0.5 0.5

PRESSURE REGULATOR SETTING STEP FULL N/A .9 2.5 N/A

3.2 3.5 10.5 3.5

Canadian Gas Association Design certified: File No. L2025006. Mounting: 0° to 90° from the upright position of gas control knob, including vertically. Body Pattern: Straight-through with 1/2" inlets and outlets. Pressure Tapping: 1/8" NPT with plug. Pressure Rating: 1/2 PSI [3.5 kPa] inlet pressure. Pilot Gas Outlet: Compression fitting for 1/4" OD tubing. Ambient Temperature Range: VR8204A,C: 0°F to 175°F [-18°C to +79°C]. VR8204M: -40°F to +175°F [-40°C to +79°C]. Electrical Data: Supply Voltage: 24 VAC, 60 Hz. Wiring Connections: 1/4" male quick-connects. Thermostat Heat Anticipator Setting: 0.5A. On-Off lighting sequence.

CAPACITY @ 1 IN. P.D.

INLET NPTI

OUTLET NPTI

PIPE IN DIM.

MLP

150,000 150,000 150,000 150,000

1/2 1/2 1/2 1/2

1/2 1/2 1/2 1/2

4.1 4.1 4.1 4.1

$117.70 232.34 106.55 133.11

VR8205A Direct Ignition Dual Automatic Combination Gas Valve Combination gas control for use with hot surface/direct spark systems in 24 VAC, gas-fired appliances with capacities from 20 to 200 cfh. Control includes manual valve, two automatic operators, and servo pressure regulator. Used with S89E,F and S87C,D Control Modules. Provides dual-seated safety shutoff. Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted. Meets codes requiring dual safety shutoff. Adjustments and wiring connections are accesSOURCE 1 PART NO. S1-VR8205A2024

114

sible from top of the control. American Gas Association and Canadian Gas Association design certified. On-Off lighting sequence. Mounting: 0° to 90° in any direction from the upright position of the gas control knob, including vertically. Body Pattern: Straight-through. Includes: 1/2” x 3/8” reducer bushing; 39369014 bag assembly—3/4” straight flange with O ring, screws and wrench; and 393691 Natural to LP gas conversion kit.

GAS TYPE

AMPS @ 24 VAC/60 HZ MAIN

PRESSURE RATING MAIN

CAPACITY

INLET NPTI

OUTLET NPTI

PIPE IN DIM.

MLP

NAT

0.5

3.5 KPA

150,000 BTU/HR MAX

1/2

1/2

4.1

$181.71

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL GAS VALVES

VR8300A Dual Standing Pilot Gas Valve

Combination gas control for use in 24 VAC, gas-fired, standing pilot appliances with capacities from 30 to 300 cfh. Features: • Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. SOURCE 1 PART NO.

INLET/OUTLET SIZE

S1-VR8300A3500

1/2 IN. X 3/4 IN.

S1-VR8300A4508

3/4 IN. X 3/4 IN.

S1-VR8300A4516

3/4 IN. X 3/4 IN.

• Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meets codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. • LITE-RITE (OFF-PILOT-ON) lighting sequence. Specifications: Type: Single Stage Ignition Type: Standing Pilot Type of Gas: Natural Body Pattern: Straight through with integral tapping; with flange Opening Characteristics (standard, step): Standard Pressure Ratings (psi): 1/2 psi CAPACITY

Pressure Ratings (kPa): 3.5 kPa Pressure Regulator Setting (psi): 3.5” W.C. Pressure Regulator Setting (kPa): 0.87 kPa Pilot Gas Outlet: Compression fitting for 1/4” OD tubing Pressure Tapping: 1/8” NPT with plug Electrical Connections: 1/4” male quick-connects Electrical Ratings: 24 VAC Frequency: 60 Hz Anticipator Setting: 0.7 A Temperature Range (F): 0°F to 175°F Temperature Range (C): -18°C to +79°C Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. Dimensions (in.): 5-3/8”H x 4-1/16”W x 2-11/16”D Dimensions (mm): 135 mm H x 104 mm W x 69 mm D Approvals: American Gas Association IAS AGA Design Certified: File No. L2025006; Canadian Gas Association CGA Design Certified: File No. L2025006; Underwriters Laboratories Inc UL Component Recognized.

@ 1 IN. P.D.

ACCESSORIES INCLUDED

190,000 BTU/HR; 30,000 BTU/HR MINIMUM 200,000 BTU/HR; 30,000 BTU/HR MINIMUM

ONE 3/4 X 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT TWO 3/4 X 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT TWO 3/4 X 1/2 IN. REDUCER BUSHINGS; 393200 ECO ADAPTER; Q340 (36 IN.) THERMOCOUPLE WITH ADAPTER; 393691 NATURAL TO LP GAS CONVERSION KIT

300,000 BTU/HR; 30,000 BTU/HR MINIMUM

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

MLP $169.84 198.69 198.06

115


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL GAS VALVES

VR8304 Dual Intermittent Pilot Gas Valve

Combination gas control for use in 24 VAC, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh. Features: • Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. • Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules. • Compact size. • Provide two automatic valves. • Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. SOURCE 1 PART NO.

INLET/OUTLET SIZE

S1-VR8304M3509

1/2 IN. X 3/4 IN.

S1-VR8304M4507

3/4 IN. X 3/4 IN.

• Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or • power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. • ON-OFF lighting sequence. Specifications: Type: Single Stage Ignition Type: Intermittent Pilot Type of Gas: Natural Body Pattern: Straight-through Opening Characteristics (standard, step): Standard Pressure Ratings (psi): 1/2 psi Pressure Ratings (kPa): 3.5 kPa

CAPACITY

Pressure Regulator Setting (psi): 3.5” W.C. Pressure Regulator Setting (kPa): 0.87 kPa Pilot Gas Outlet: Compression fitting for 1/4” OD tubing Pressure Tapping: 1/8” NPT with plug Electrical Connections: 1/4” male quick-connects Electrical Ratings: 24 VAC Frequency: 60 Hz Anticipator Setting: 0.7 A Temperature Range (F): -40°F to +175°F Temperature Range (C): -40°C to +79°C Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. Dimensions (in.): 5-3/8”H x 4-1/16”W x 2-11/16”D Dimensions (mm): 135 mm H x 104 mm W x 69 mm D Approvals: American Gas Association IAS AGA Design Certified: File No. L2025007; Canadian Gas Association CGA Design Certified: File No. L2025007; Underwriters Laboratories Inc UL Component Recognized.

@ 1 IN. P.D.

ACCESSORIES INCLUDED

270,000 BTU/HR; 30,000 BTU/HR MINIMUM 300,000 BTU/HR; 30,000 BTU/HR MINIMUM

ONE 3/4 X 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT TWO 3/4 X 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT

MLP $266.98 207.02

VR8345 Universal Electronic Ignition Combination Gas Control Features: • For use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 VAC, gas-fired appliances, with capacities from 30 to 415 cfh. • For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas. • Control includes: manual valve, two automatic operators, pressure regulator, pilot adjustment, pilot plug and ignition adapter, two 3/4” x 1/2” NPT reducer bushings and one 1/2” x 3/8” NPT bushing. • Replaces virtually any IP, HSI or DSI gas control. SOURCE 1 PART NO. S1-VR8345M4302

116

• Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/HSI jumper. • Internal inlet screen blocks contaminants in gas line from entering valve. Body Pattern: Straight-through with 3/4” x 3/4” inlet and outlet. Dimensions: 5-3/8” H, 4-1/16” W, 2-11/16” D (135 mm H, 104 mm W, 69 mm D) Approvals: AGA Design Certified: File number L2025007; CGA Design Certified: File number L2025007.

IGNITION

VOLTAGE

OPENING

INLET X OUTLET

FUEL

MLP

DIRECT/ INTERMITTENT PILOT

24

STANDARD

3/4 X 3/4

NAT/LP

$226.43

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HONEYWELL GAS VALVES

SV950 SmartValve™ System Gas Valve

The SmartValve™ System Controls provide intermittent pilot gas ignition sequencing, pilot flame sensing, and both pilot and main gas control functions in a single control. They are directly compatible with the Q3450 or Q3480 SOURCE 1 PART NO. S1-SV9501M2528

GAS TYPE NAT

intermittent pilot burners used with the original controls on many gas fired heating appliances. Features: • Suitable for a wide range of gas-fired appliances including residential furnaces, rooftop furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units. • Replaces SV9500, SV9501 and SV9502 SmartValve™ System models. • Ignition sequence includes timed trial for ignition. • Pilot gas outlet Specifications: Flame Sense: Electrode Ignition System Type: Intermittent hot surface pilot ignition

PRESSURE REGULATOR SETTING 3.5” WC (0.87 KPA)

PRESSURE RATINGS 1/2 PSI (3.45 KPA)

Ignition Sequence: Intermittent pilot Ignition Source: Pilot Ignition Trials to Lockout: Continuous retry Ignition Trial Time: 90 sec. Flame Failure Response Time: 1.6 sec. @ 3 µA Prepurge: None Body Pattern: Straight-through Opening Characteristics: Standard opening Ambient Temperature Range: –40° to +175°F (–40° to +79°C) Electrical Ratings: 24 VAC Frequency: 60 Hz/50 Hz Approvals: American Gas Association IAS, IAS Design Certified: C2030017

CAPACITY MAXIMUM

MINIMUM

INLET NPT

OUTLET NPT

MLP

200 FT3/HR (5.7 M3/HR) 150 FT3/HR AT 1” P.D. (20 M3/HR AT 1” P.D.)

0.6 M3/HR

1/2”

1/2”

$335.45

Conversion Kits

SOURCE 1 PART NO. S1-391937 S1-393691 S1-393691-2 S1-394588 S1-391937-4 S1-391936

DESCRIPTION NATURAL GAS TO LP CONVERSION KIT, INCLUDING REGULATOR SPRING, O-RING, SCREW AND CAP NATURAL GAS TO LP CONVERSION KIT, INCLUDING REGULATOR SPRING, SCREW AND CAP NATURAL TO LP GAS CONVERSION KIT; INCLUDES REGULATOR SPRING, SCREW AND CAP, AND ORIFICE (SIZE - 010) LP TO NATURAL GAS CONVERSION KIT; INCLUDES REGULATOR SPRING, SCREW AND CAP. NATURAL TO LP GAS CONVERSION KIT, INCLUDES REGULATOR SPRING, O-RING, SCREW, CAP AND ORIFICE (SIZE - 012) LP TO NATURAL GAS CONVERSION KIT; INCLUDES REGULATOR SPRING, O-RING, SCREW AND CAP.

FOR USE WITH

MLP

V800, VS821, VS820

$ 7.14

VR8200, VR8300, VR4200, VR4300 VR8200, VR8300, VR4200, VR4300 Standard (A,M) and Slow (H).

14.83

8.57

V800 FAMILY, VS820, VS821 STANDARD AND SLOW.

11.43

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

9.57 12.98

117


hemrichelectric.com

info@hemrichelectric.com

POWER GENERATORS, THERMOCOUPLES, HOT SURFACE IGNITERS

White Rodgers 750 Millivolt Power Generator Provides power for 750 millivolt self-generation control systems. Features: • For replacement of similar screw-in type generators now in field or for use with type E3112 pilot burner. • G01A-332 has 36 inch armored cable leads with split-spade terminals. • PG9 Adapter included with each G01A-332. SOURCE 1 PART NO. S1-G01A-512 S1-G01A-332

DESCRIPTION

MLP

750 MV W/36” LEADS (FIBERGLASS) WITH F SPADE CLIPS 750 MV W/36” LEADS (ARMORED CABLE) AND PG9 ADAPTER

$57.86 68.74

White Rodgers Universal Replacement Thermocouples High temperature stainless steel element specially designed for universal replacement. Features: • Stainless steel element construction for prolonged thermocouple life. • Each kit individually enclosed in plastic. SOURCE 1 PART NO. S1-H06E-18 S1-H06E-24 S1-H06E-30 S1-H06E-36 S1-H06E-48 S1-H06E-72

118

• Universal adapter fittings included with each kit for replacing thermocouple in most types of pilot burners. • Visible instructions for quick, easy installation.

DESCRIPTION

MLP

UNIVERSAL 18” THERMOCOUPLE UNIVERSAL 24” THERMOCOUPLE UNIVERSAL 30” THERMOCOUPLE UNIVERSAL 36” THERMOCOUPLE UNIVERSAL 48” THERMOCOUPLE UNIVERSAL 72” THERMOCOUPLE

$ 8.74 9.09 9.53 12.24 11.81 17.39

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

POWER GENERATORS, THERMOCOUPLES, HOT SURFACE IGNITERS

Direct-Brand Universal Silicon Nitride Hot Surface Igniters

SOURCE 1 PART NO. NEW

S1-HSIURK120VF S1-HSIURK120VR S1-SLURK24V

DESCRIPTION

MLP

IGNITER, HSI, 120V, SILICON NITRIDE, FLAT IGNITER, HSI, 120V, SILICON NITRIDE, RND IGNITER, HSI, 24V, SILICON NITRIDE

$70.82 59.07 59.07

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

119


hemrichelectric.com

info@hemrichelectric.com

Direct-Brand Universal Silicon Nitride Hot Surface Igniters Cross Reference The S1-HSIURK120VF and S1-HSIURK120VR Glo-stix™ 120v igniters are a universal direct upgrade, replacing Silicon Carbide hot surface igniters. They are made from durable Silicon Nitride. Note: These units cannot be used as a flame sensor. EQUIPMENT MFR

MFR IGNITER PART NO.

AMERICAN ROAD EQUIP ACRO AIR ARMSTRONG AIR CARRIER CORP CLAIRE BROS COLEMAN COMFORT MAKER DETROIT RADIANT DMO INDUSTRIES DORNBACK FURNACE DUCANE ENERCO TECH EVCON GOODMAN HEIL HUPP INDUSTRIES INTERCITY MAJESTIC METZGER MOR-FLO NORDYNE NORTON RAYPAK RHEEM ROBERTS GORDON ROBERTSHAW SMITH HB SNYDER GENERAL SUPERIOR FIREPLACE TEMPSTAR TRANE VIESSMAN WAYNE HOME EQUIPMENT WEIL MCLAIN WHITE LB COMPANY

201W 1096048, 1380680 38322B001 LH33ZS001A, LH33ZS002 C-238, C-242 1474-051, 1474-052 1096048 201D 20834 271W 20015201 10399 1474-051, 1474-052 B10401009 1096048 09050 1009604, 1096048 75-92-104, 75-92-105 201N, 201W 3200618 105141000, 632-0770, 632-0880, 902661, 902694, 903310, FC007 201, 201D, 201K, 201L, 201R, 201W, 271, 271D, 271M, 271N, 271NM, 271P, 271W 600915 62-22441-01, 62-22868-82, 62-22868-93 90434300, 90436600 41-402, 41-403, 41-404, 41-405, 41-407, 41-408, 41-409, 41-410, 41-411, 41-412, 41-414 50018 1380654, 1380672, 1380680 94851 1096048, 1148245 340039P01, B138196P01, B144676P01, B144676P02, B340039P01, IGN21, IGN23, IGN26, IGN30 9302-094 62821-001, 62821-002 511-330-139, 511-330-190, 511-330-193 120-07549 767A-301, 767A-303, 767A-306, 767A-310, 767A-311, 767A-350, 767A-353, 767A-354 , 767A-357, 767A-361, 767A364, 767A-365, 767A-366, F767A-357, F767A-361, F767A-365, F767A-366 09050 025-27766-000, 025-27774-000, 025-29043-000, 025-29050-000, 025-32625-000, 025-32626-000, 025-33421-000, 373-05342-700, 473-12509-001

WHITE-RODGERS WILLIAMSON YORK

The S1-SLURK24V smart-lite™ igniter flame rod assembly is a direct replacement for all 24 volt hot surface igniter SmartValve™ systems and includes equipment made by AO Smith, Armstrong Furnace, Bradford White, Ducane and Skymark. USED IN SMART VALVES INCLUDING: SV9500 SV9500M2603 SV9500M2674 SV9500M2682 SV9500M-2682 SV9501M2528 SV9600 SV9600H SV9401 SV9402 SV9403 SV9501 SV9502 SV9503 SV9601 SV9602

120

REPLACES IGNITER FLAME ROD ASSEMBLY INCLUDING: 1009524 1149856 42640001 CARQ3400A1024 Q3400A Q3400A1016 Q3400A1024 Q3400A1040 Q3450 Q3480 Q3620

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

POWER GENERATORS, THERMOCOUPLES, HOT SURFACE IGNITERS

Source 1 Hot Surface Igniters • Replaces Carrier, Lennox, Rheem, Trane, and others • Can reach ignition temperature(s) in 17 seconds See following table for cross-reference information.

Source 1's Norton hot surface igniters are made of high purity recrystallized silicon carbide to provide reliable ignition in a variety of heating systems.

SOURCE 1 PART NO. S1-52541058401 S1-52541058402 S1-52541058403 S1-52541058404 S1-52541058405 S1-52541058406 S1-52541058407 S1-52541058408 S1-52541058409 S1-52541058410 S1-52541058411 S1-52541058412 S1-52541058414

• 18-gauge nickel chrome lead wires enclosed with high-temperature fiberglass insulation • Compare to Robertshaw R 41-400 Series

DESCRIPTION

MLP

KIT,IGNITER,HOT SURFACE, 271A, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271W, 19" LEADS KIT,IGNITER,HOT SURFACE, 271M, 5-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271M, 5-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271D, 10-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271Y, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271M, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271N, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271M, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271N, 5-1/4" LEADS KIT,IGNITER,HOT SURFACE, 271N, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271NM, 4-1/2" LEADS KIT,IGNITER,HOT SURFACE, 271NM, 5-1/4" LEADS

$46.25 46.25 46.25 42.68 49.82 49.82 46.25 46.25 46.25 46.25 42.68 35.54 60.54

HOT SURFACE IGNITER CROSS REFERENCE Exact replacements are designated by an *. All other igniters are functional replacements. OEM PART NO. AMANA B1336102 D99182 10041601 AMERICAN APPLIANCE 271B AMERICAN ROAD EQUIPMENT 201W ARMSTRONG AIR 38322B001 CARRIER CORPORATION LH33ZS001A LH33ZS002 COLEMAN/EVCON 1474-051 1474-052 COMFORT ZONE 150114-04-01 DETROIT RADIANT 201D DMO INDUSTRIES 20834 DORNBACK FURNACE 271W DUCANE 20015201 ENERCO TECH 10399 GOODMAN B1401009 B1401015S HUPP INDUSTRIES 9050 INTERCITY 1009604 MAJESTIC 75-92-104 75-92-105 METZGER 201N 201W MODINE 5H75032

SOURCE 1 PART NO. S1-5254105401 S1-52541058401* S1-52541058401* S1-52541058406* S1-52541058402 S1-52541058402 S1-52541058409* S1-52541058409* S1-52541058402 S1-52541058402 S1-52541058406 S1-52541058405 S1-52541058402 S1-52541058402 S1-52541058409* S1-52541058402 S1-52541058412* N/A S1-52541058402 S1-52541058412* S1-52541058402 S1-52541058402 S1-52541058402 S1-52541058402 N/A

OEM PART NO. MOR-FLO 3200580 3200618 3210401 NORDYNE 105141000 632-0880 632-0770 FC007 902661 FC047K 903110 NORTON 201 201A 201D 201J 201K 201L 201N 201R 201W 201Y 271 271A 271P 271M 271N 271NM 271W 271Y PERFECTION SCHWANK 108803-G1 RAYPAK 600915 RHEEM 62-22441-01 62-22441-01 62-22868-82 SP-10972 ROBERTS GORDON 90434300 90436600

SOURCE 1 PART NO. S1-52541058406* S1-52541058402 S1-52541058406 S1-52541058402 S1-52541058402 S1-52541058402 N/A N/A N/A N/A S1-52541058403 S1-52541058401 S1-52541058405 S1-52541058406 S1-52541058402 S1-52541058402 S1-52541058402 S1-52541058402 S1-52541058402 S1-52541058406 S1-52541058403 S1-52541058401 S1-52541058405 S1-52541058406 S1-52541058402 S1-52541058412 S1-52541058402 S1-52541058406 S1-52541058406

OEM PART NO. SMITH HB 50018 SNYDER GENERAL 1380672 1380680 1380654 TRANE COMPANY B138196P01 B144676P02 B340039P01 340039P01 IGN21 IGN23 IGN26 IGN26 IGN30 IGN30 3033 KIT VIESSMAN 9302-094 WAYNE HOME EQUIPMENT 62821-001 62821-002 WELL MCLAIN 511-330-139 511-330-188 511-330-193 WILLIAMSON 9050 YORK INTERNATIONAL 025-27766-000 025-27774-000 025-29043-000 025-29050-000

SOURCE 1 PART NO. S1-52541058405* S1-52541058409* S1-52541058409* S1-52541058403 S1-52541058403 S1-52541058407* S1-52541058408* S1-52541058402 S1-52541058402 S1-52541058409* S1-52541058403 S1-52541058407* S1-52541058403 N/A S1-52541058405* S1-52541058402 S1-52541058402 S1-52541058409* S1-52541058406* S1-52541058403 S1-52541058402 S1-52541058405* S1-52541058405* S1-52541058405* S1-52541058405*

S1-52541058403 S1-52541058408 S1-52541058402 S1-52541058411* N/A S1-52541058409 S1-52541058402

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

121


hemrichelectric.com

info@hemrichelectric.com

POWER GENERATORS, THERMOCOUPLES, HOT SURFACE IGNITERS

White Rodgers Universal Nitride Hot Surface Upgrade Kit Silicon Carbide Ignition Upgrade for Gas Furnaces & Gas Boilers

The Nitride Upgrade Kit is tough, reliable and universal. The kit uses an adapter module, uni-

versal bracket, Nitride igniter, and a wiring harness to upgrade an existing Silicon Carbide igniter to a Nitride igniter. The adapter module connects the nitride igniter to the existing HSI module, adjusting the power to the Nitride igniter. The igniter and adapter module replaces only the Silicon Carbide igniter. The upgrade kit also includes a label for the furnace to let everyone know that the furnace has been upgraded to Nitride. Features: • Robust Nitride igniter • One “Universal” Bracket fits most furnaces • 5 year warranty • Power On LED Indicator

SOURCE 1 PART NO. S1-21D64-1

• Surface Mount Technology for reliability Typical Applications: Gas fired forced air furnaces and boilers. Specifications: • Electrical Rating: Input 102–132 VAC, 60 HZ • Maximum Load Current: 7.0A @ 132 VAC, 25° C • Line Frequency: 60 HZ • Timing Rating: 15 seconds minimum • Maximum Dimensions: 2”H x 4-1/4” x 5-1/4”L

DESCRIPTION

MLP

UNIVERSAL NITRIDE HOT SURFACE UPGRADE KIT

$162.62

POWER GENERATORS, PILOT BURNERS & PILOT CONTROLS

Honeywell Q313 Thermopile Generator Q313 Thermopile Generator contains multiple thermocouples connected in series to increase the millivoltage output. The power generated is sufficient to operate an automatic millivolt gas control system, independent of any outside power source. Features: Push-in clip, split nut, and adapter assembly for easy pilot burner installation. Spade or quick-connect terminals available for millivolt gas control connections. Male nut connector for Pilotstat® safety control power units. SOURCE 1 PART NO. S1-Q313A1055 S1-Q313A1139

122

LEAD LENGTH 47 IN. (1194 MM) 35 IN. (889 MM)

Available in a variety of lead lengths. Specifications: Voltage 750 mV Connection Type Spade Terminals Open Circuit Output (mV) 600 mV to 750 mV Temperature Ratings (F) Hot Junction 1400 F Temperature Ratings (C) Hot Junction 760 C Temperature Ratings (F) Cold Junction 780 F Temperature Ratings (C) Cold Junction 416 C Used With Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners

RESISTANCE

ACCESSORIES INCLUDED

MLP

2.90 OHM

1/2 IN. THERMOPILE ATTACHING NUT

$83.65

2.89 OHM

PUSH-IN CLIP

90.63

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

POWER GENERATORS, PILOT BURNERS & PILOT CONTROLS

Honeywell Pilot Burner for Natural Gas Nonprimary-aerated combination pilot burner and igniter. Used with the S86, S860, S8610, or S8670 in intermittent pilot systems. Features: Includes pilot burner with bracket, ceramicinsulated Kanthal flame rod/spark igniter and ground strap. Specifications: Type of Gas: Natural Direction of Front Tip: (F) Front Tip Style: Single Aeration: Non-primary

SOURCE 1 PART NO.

Leadwire Temperature Ratings (C): Max. at electrode tip: 968°C Includes: 1/4" cc inlet fitting and mounting adapter

MOUNTING BRACKET

COMPRESSION FITTING LENGTH

ORIFICE

MLP

B

1-1/4 IN.

BCR-18 (0.018 IN.)

$46.58

S1-Q345A1305

IGNITION MODULES & INTEGRATED FURNACE CONTROLS

White Rodgers Mercury Flame Sensors able pilot flame. It converts the heat of a pilot flame to motion which is used to open and close a set of electrical contacts, and consists of a bulb, capillary, diaphragm, snap-switch mechanism, and mercury-fill. When the bulb is heated by a pilot flame, the mercury is vaporized causing pressure in the capillary and diaphragm. Movement of the diaphragm causes the snap-switch to open one set of contacts, and close a second set. These contacts control the pilot valve and the main valve. Features: • Bulb styles are designed to fit with various OEM applications. • Adapter fittings to allow use of these mercury flame sensors with competitive burners are packed with controls identified with an asterisk (*).

3049-64

The mercury flame sensor is a mechanical device that proves the existence of an acceptSOURCE 1 PART NO.

• A.G.A. Design certified and C.G.A. Certified. • Maximum temp. 1450°F at bulb tip.

ELEMENT LENGTH

PANEL TYPE

BULB STYLE

DESCRIPTION

MLP

48” 33” 48” 48” 48” 48”

B D D E E D

#3 #7 #19 #19 #20 #20

STUD MOUNT BULB — REPLACES BULB STYLES #9 OR #13. REPLACES BULB STYLES #9 OR #13. REPLACES BULB STYLES #17 OR #18. REPLACES BULB STYLES #17 OR #18.

$236.55 226.48 236.55 236.59 236.59 236.55

S1-3049-5 S1-3049-18 S1-3049-64* S1-3098-134* S1-3098-156* S1-3049-115*

*Adapter fittings packed with control. SOURCE 1 PART NO. S1-30A46-5

ELEMENT LENGTH 48”

ELECTRICAL RATING 120 VAC 240 VAC 30 VAC 125 VA

125 VA

90 VA

COMMENTS

MLP

STUD MOUNT ELEMENT

$248.70

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

123


hemrichelectric.com

info@hemrichelectric.com

IGNITION MODULES & INTEGRATED FURNACE CONTROLS

White Rodgers Pilot Relite Control Ignition control generates spark pulses to ignite pilot gas. The relite control generates sparks until a pilot flame is sensed between the electrode and ground. The relite control detects a flame through “flame conduction” (ability of a flame to conduct a current). When flame current is sensed between the electrode and pilot burner ground, the relite control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.

5059-23 SOURCE 1 PART NO. S1-5059-23

Features: A.G.A. Design certified and C.G.A. certified.

INPUT VOLTAGE

ELECTRICAL RATING

DESCRIPTION

MLP

24 VAC

0.03 AMPS

SPARK PLUG AND 1/4” SPADE CONNECTORS

$166.55

White Rodgers Combination Relite Control and Lockout Timer Combines in one enclosure the functions of a 5059 relite control and a 5022 timer. Features: • Includes all the features of a 5059 Relite control. SOURCE 1 PART NO. S1-50A22-4

50A22-4

• Lockout timer opens circuit if flame is not sensed in ignition period. • Replaces previous 5022 timers. Specifications: A.G.A. design certified and C.G.A. certified.

INPUT VOLTAGE

ELECTRICAL RATING

DESCRIPTION

MLP

24 VAC

0.11 AMPS

5 WIRE EDGE CONNECTOR

$305.63

Honeywell Universal Retrofit Intermittent Pilot Gas Burner Ignition Systems

Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 VAC gas-fired atmospheric furnaces, boiler and heating appliances. SOURCE 1 PART NO. S1-Y8610U3003

124

Features: • Y8610U kits are for use with natural or LP gas: provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. • Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed. Specifications: Ignition System Type: Intermittent Pilot Ignition Sequence: Continuous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place Type of Gas: Natural or LP

CAPACITY (BTUH) C

INLET-OUTLET SIZE (IN.)

REDUCER BUSHINGS

270,000

1/2 X 3/4

TWO 3/4 X 1/2 IN.

Flame Sense: Single Rod Ignition Source: Internal high voltage spark generator PrePurge: None Typical Ignition Hardware: Q345, Q3451 Dimensions (in.): 3-15/16”H x 5-7/16”W x 2-5/8”D Dimensions (mm): 100 mm H x 138 mm W x 67 mm D Electrical Ratings: 24 VAC Frequency: 60 Hz Flame Failure Response Time (sec): 0.8 sec. @ 1.0 microamp

TEMPERATURE RANGE °F °C –40 TO +165

STOCKED NON STOCKED

–40 TO +74

TYPE OF GAS

MLP

NATURAL OR LP

$491.12

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

IGNITION MODULES & INTEGRATED FURNACE CONTROLS

Honeywell S8610U Universal Intermittent Pilot Module

Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers and other heating appliances. Provides ignition sequence, flame monitoring and safety shutoff (max. 90 sec.) for intermittent pilot central furnaces and heating appliances. Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. For use with natural or LP gas. For use in single rod or dual rod/remote sense applications.

Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended. Functional equivalent of S86, S90, S8600 and S8610 modules. Includes cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing cable. Improved enclosure design protects internal circuitry from moisture or dust accumulation. Includes remote reset, and automatic vent damper plug. Replaces most of the following intermittent pilot modules: — Honeywell S86, S90, S8600 and S8610 — Robertshaw SP715, SP715A, SP735, SP735A, SP735L — Johnson GSA, G60, G65, G67, G600, G770 Refer to S8610 specification sheet for a complete list of model numbers. APPROVAL BODIES: American Gas Association Design certified. Canadian Gas Association Design certified. SOURCE 1 PART NO. S1-S8610U3009

Underwriters Laboratories Inc. Component recognized. AMBIENT TEMPERATURE RATING: –40°F to +165°F [–40°C to +74°C]. FLAME FAILURE RESPONSE TIME: 0.8 sec. At 1.0 mA flame current. WIRING CONNECTIONS: 1/4" male quickconnect terminals, including ignition terminal (3/16" male quick-connect sense terminal). ELECTRICAL RATINGS: Voltage and Frequency – 24V (nominal), 60 Hz. Current rating – 0.2A

PILOT MAIN

RUNNING

INRUSH

1.0A 2.0A

10.0A 20.0A

NOTE: Maximum ambient temperature is 175°F [79°C] if main valve relay load is 1.0A or less. THERMOSTAT HEAT ANTICIPATOR SETTING: 0.2A plus pilot valve rating plus main valve rating. Spark Generator Output – 13 kV peak at 25 pf load.

MLP $302.97

Honeywell Switching Relay Provide intermediate switching of a line voltage device from a low voltage controller. Features: Integral transformer provides low voltage power for control circuit. Specifications: Application: For switching one line voltage load Frequency: 60 Hz;50 Hz Temperature Range (F): 115°F Max. Ambient for 60 Hz Temperature Range (C): 46°C Max. Ambient for 60 Hz SOURCE 1 PART NO.

SWITCHING ACTION

AFL

SPST

10.2

S1-RA89A1074

CONTACTS ELECTRICAL RATINGS ALR RESISTIVE 61.2

10.0A

Dimensions (in.): 5-1/4”H x 4-1/4”W x 2-5/16”D Dimensions (mm): 133 mm H x 108 mm W x 59 mm D Electrical Ratings -Primary Voltage: 120V Electrical Connections (Control Circuit): 2Wire Approvals: Underwriters Laboratories Inc UL Listed: File no. E4436, Guide no. XAPX; Canadian Standards Association CSA Certified Includes: Integral transformer, enclosure Contacts Electrical Ratings (240 VAC): 5.1 AFL, 30.6 ALR, 6.0A resistive. COIL RATINGS CURRENT VOLTAGE 0.4A

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

24 VAC

MLP $127.42

125


hemrichelectric.com

info@hemrichelectric.com

IGNITION MODULES & INTEGRATED FURNACE CONTROLS

Honeywell Direct Spark Ignition Control

Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliances.

SOURCE 1 PART NO.

TYPE OF GAS

S1-S87D1004

NATURAL OR LP

Features: • Control ignition sequence and gas control operation. • Generate high voltage potential for main burner ignition. • Lockout after one trial for ignition if main burner fails to ignite. • Reset from thermostat after lockout. • Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less. Specifications: Ignition System Type: Direct Spark Ignition Ignition Sequence: Multiple trials for main burner ignition (then shut down and lockout) Typical Gas Control: VR8205, VR8305

Flame Sense: Two Rods Ignition Source: Internal high voltage spark generator PrePurge: None Typical Ignition Hardware: Q347A, Q354, Q366 Dimensions (in.): 5-1/4”H x 4-1/16”W x 1-15/16”L Dimensions (mm): 133 mm H x 103 mm W x 49 mm D Electrical Ratings: 24 VAC Frequency: 60 Hz Maximum Ambient Temperature (F): -40°F to +175°F Maximum Ambient Temperature (C): -40°C to +79°C

IGNITION TRIALS TO LOCKOUT

LOCKOUT TIMING

IGNITION TRIAL TIME

MAXIMUM VALVE LOAD @ 24 VAC

RESPONSE TIME

RE-IGNITION TIME

MLP

1

6 SEC.

6 SEC.

2A

0.8 SEC. @ 5.0 MICROAMP

0.8 SEC. MAXIMUM

$296.03

FLAME FAILURE

Honeywell Single Rod Hot Surface Ignition Control

Provide operating control and system shutdown on loss of main burner flame in direct ignition central heat furnaces and heating appliances with hot surface igniter. Features: • S89C,G,J are for systems with a combination igniter-sensor. • S89C lock out after one try for ignition.

SOURCE 1 PART NO. S1-S89C1087

TYPE OF GAS

• S89G,H provide three tries for ignition before lockout, with 30 sec. min. purge before second and third tries. • Compatible with Norton 201 and 271 or equivalent hot surface igniters. • Available with leadwires for line voltage connections. • Available with Molex plug for connecting D80D Vent Damper. • Modules can be used on either natural or LP gas; they provide 100 percent shutoff of gas on lockout. • Modules have relay contacts for use with any direct ignition gas control with max. 2.0 A, 24 V at rating. • Modules use rectification principle for flame sensing. • Minus 40°F to 175°F [minus 40°C to +79°C] temperature rating. Specifications: Ignition System Type: Direct Hot Surface Ignition

Ignition Sequence: Single trial for main burner ignition [then shut down and lockout] Typical Gas Control: VR8205, VR8305 Flame Sense: Single Rod Ignition Source Line Voltage (120 VAC): Hot Surface Element (Norton Model 201) PrePurge: None Typical Ignition Hardware: Norton 201 Dimensions (in.): 5-1/4”H x 4-1/16”W x 1-15/16”L Dimensions (mm): 133 mm H x 103 mm W x 49 mm D Electrical Ratings: 24 VAC Frequency: 60 Hz Maximum Ambient Temperature (F): -40°F to +175°F Maximum Ambient Temperature (C): -40°C to +79°C Approvals: Canadian Standards Association Design Certified

IGNITION TRIALS TO LOCKOUT

LOCKOUT TIMING

IGNITION TRIAL TIME

MAXIMUM VALVE LOAD @ 24 VAC

FLAME FAILURE RESPONSE TIME

MLP

1

6 SEC.

6 SEC.

2A

2.0 SEC. @ 2.5 MICROAMP

$257.18

NATURAL OR LP

Universal Silicon Carbide Integrated Ignition Module The 50A55-843 employs a microprocessor to continually monitor, analyze and control the proper operation of the gas burner, inducer and fan. Electrical Ratings at 77°F (25°C): Input Voltage: 25 VAC 50/60 Hz SOURCE 1 PART NO. S1-50A55-843

126

Maximum Input Current: at 25 VAC 0.45 amp Operating Temperature: –40° to 176°F (–40° to 80°C) Humidity: 5% to 93% relative humidity (noncondensing)

DESCRIPTION

REPLACES

MLP

UNIVERSAL SILICON CARBIDE INTEGRATED IGNITION MODULE

50A55-143 50A55-285 50A55-286 50A55-438

$240.00

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

FAN & LIMIT CONTROLS

White Rodgers Fan & Limit Controls for Universal Replacement Single element type for applications with narrow space limitations. Regulates fan or blower operation and acts as high limit safety control. Features: • Designed to be interchangeable with other flush mounted, single element fan and limits. • Slotted mounting holes for easy installation. • Long Terminal screws for wiring—Junctions can be made on terminal block. • Limit switch has “universal” contact structure capable of handling millivolts to 240 VAC. • Limit switch has adjustable stop to limit maximum setting—Shipped at 200° F (94° C).

• Dial has individual pointers for fan cut-in and cut-out settings. • Removable solid copper jumper between fan and limit switches. • Summer fan switch for ventilation without changing control settings. Has same fan and limit switch mechanism. • C.S.A. Certified and U.L. Recognized.

5D51-35

Specifications and Cross Reference: VENDOR TYPE NO.

DESCRIPTION FAN

5D51 SERIES

LIMIT

SWITCH ACTION

FULL ELECTRICAL RATING

MOTOR RATING (FULL LOAD) 120 VAC 240 VAC

VALVES AND RELAYS 24 VAC 0.3-12V DC

RANGE

DIFFERENTIAL

50 TO 265° F (10 TO 129° C) 100 TO 300° F (38 TO 149° C)

ADJUSTABLE 15° F MINIMUM

CLOSE ON RISE

HT

14.0A

7.0A

FIXED 25° F

OPEN ON RISE

HTV

10.0A

6.0A

6.0A

1.0A

SOURCE 1 PART NO.

ELEMENT LENGTH

DESCRIPTION

MLP

5” 11” 8”

WITH STANDARD ENCLOSURE

$125.08 125.08 125.08

S1-5D51-35 S1-5D51-78 S1-5D51-90

Honeywell L4064W Fan & Limit Controls For control of high limit and fan motor in all types of forced air heating systems. Features: • Three wiring terminal options available for easy installation: —push-in receptacles for stripped wire, —female receptacles for 1/4-in. male flag —connectors, and —field add-on screw terminals.

SOURCE 1 PART NO. S1-L4064W1080* S1-L4064W1098*

S1-L4064W1106*

APPLICATION BIMETAL HEATER SWITCH TURNS FAN ON APPROXIMATELY 20 TO 90 SECONDS AFTER THERMOSTAT CALLS FOR HEAT AT A COLD START. HIGH LIMIT STOP FACTORY-SET AT 200°F [93°C]. REPLACED L4064T,Y

INSERTION ELEMENT IN. MM 5 8

127 203

11-1/2

292

MOUNTING

• Controls adapt to many competitive mounting holes in replacement applications. • Available in a variety of fan and high limit setting ranges. • SUPER TRADELINE models include deluxe case with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse.

INCLUDES

TWO LEADWIRES WITH ¼ IN. [6 MM] MALE FLAG TERMINALS ATTACHED, TWO ¼ IN. [6 MM] FEMALE SURFACE OR QUICK-CONNECT TERMINALS FOR LOW RIGID VOLT HEATER BRACKET TERMINAL CONNECTION, FOUR ADD-ON SCREW TERMINALS, AND TWO JUMPERS FOR LINE VOLTAGE FAN AND LIMIT INTERCONNECT.

MLP $188.18 188.18

188.18

*With manual fan switch to override fan set points and keep fan running continuously.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

127


hemrichelectric.com

info@hemrichelectric.com

FAN & LIMIT CONTROLS

Honeywell L4064 Fan & Limit Controls For control of high limit and fan motor in all types of forced air heating systems. Features: • Three wiring terminal options available for easy installation: push-in receptacles for stripped wire, female receptacles for 1/4” male flag connectors, and field add-on screw terminals. • Controls adapt to many competitive mounting holes in replacement applications. • Available in a variety of fan and high limit setting ranges. • Super Tradeline models include deluxe case with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse. Specifications: Application: Turns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop factory set at 200ºF (93ºC). Replaces L4064A,B,E. Fan-on Range: 65ºF to 215ºF (18ºC to 102ºC Fan-off Range: 50ºF to 200ºF (10ºC to 96ºC) Pilot duty: 0.25 A @ 0.25 to 12 Vdc, 2 A @ 24 VAC Dimensions: 5-3/8”H x 3”W x 2”D (137 mm H x 76 mm W x 51 mm D) excluding element. Mounting: Rigid bracket.

L404B1451

Differential Temperature: 25ºF (14ºC), fixed. Approvals: UL Listed; CSA Certified.

L4064B1469

SOURCE 1 PART NO.

HIGH LIMIT TEMPERATURE RANGE

ELEMENT INSERTION LENGTH

100ºF TO 250ºF (38ºC TO 121ºC)

11-1/2” (292 MM) 5” (127 MM) 8” (203 MM)

S1-L4064B1451* S1-L4064B1469* S1-L4064B2236

MAX. AMBIENT TEMPERATURE RATINGS SENSING SWITCH ELEMENT

ELECTRICAL RATING FAN

ELECTRICAL RATING LIMIT

(AFL)

(ALR)

(AFL)

(ALR)

7 A @ 240 VAC, 14 A @ 120 VAC

42 A @ 240 VAC, 84 A @ 120 VAC

4 A @ 240 VAC, 8 A @ 120 VAC

24 A @ 240 VAC, 48 A @ 120 VAC

MLP $159.65

190ºF (88ºC)

350ºF (177ºC)

158.85 126.67

*L4064B models have manual fan switch that overrides fan control to keep fan running continuously.

Honeywell L4068 Fan Control Operate furnace fan motor according to air temperature in all types of forced air heating systems. Features: • Flat bimetal element, inserted into the airstream, actuates a snap-acting switch. • Manual switching for continuous fan operation. • Push-in terminals. Specifications: Application: Forced warm air heating systems Switching Action: SPST, snap acting makes on temperature rise. Pilot Duty: 50 Va @ 24 VAC SOURCE 1 PART NO.

S1-L4068E1054

128

HIGH LIMIT ELEMENT TEMPERATURE INSERTION RANGE LENGTH

80°F TO 120°F

7 IN. (178 MM)

MAXIMUM AMBIENT TEMPERATURE

ELECTRICAL RATING FAN (AFL)

(ALR)

Differential Temperature (F): 20°F to 50°F, adjustable Differential Temperature (C): 11°C to 28°C, adjustable Dimensions (in.): 3-3/4”H x 2-5/16”W x 2-3/8”D Dimensions (mm): 95 mm H x 59 mm W x 60 mm D Approvals: Canadian Standards Association Component Recognized: File No. LR1322, Guide No. 400-E-O Comments: Closes circuit on temperature rise. Bimetal sensing element actuates switch. With case and cover. Manual “fan on” lever. Honeywell monogram. FAN-OFF RANGE

FAN-ON STOP

FAN-OFF STOP

MLP

SWITCH: 190 F; MAX AT BIMETAL 125°F 100°F ELEMENT: 350 F 14 A @ 120 VAC; 84 A @ 120 VAC; 80°F TO 120°F. ADJ. (FACTORY (FACTORY $137.34 (SWITCH: 88 C; 7 A @ 240 VAC 42 A @ 240 VAC 27°C TO 49°C, ADJ. SET) SET) MAX AT BIMETAL ELEMENT: 177 C)

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

FAN & LIMIT CONTROLS

White Rodgers Fan or Limit Controls Provides high limit protection for warm air furnaces or controls blower operation. Features: • Interchangeable with competitive makes. • Adjustable differentials remain constant through entire range of control. • Limit control has “universal” contacts capable of handling millivolts to 240 VAC. • Limit control equipped with adjustable stop to limit setting. Shipped at 200° F/93°C.

• Both fan and limit controls have screw terminals. • U.L. Recognized and C.S.A. certified.

Fan Types Without Enclosure

SOURCE 1 PART NO.

RANGE (CUT-OUT)

S1-5C22-2

170°–125°F 1

S1-5C22-52

1 70°–125°F 1(21°–52° C)

(21°–52° C)

DIFFERENTIAL ADJ. 25°–50° F (14°–28° C) ADJ. 25°–50° F (14°–28° C)

MOTOR RATING (FULL LOAD) 120V 240V AC AC

VALVES & RELAYS 24V 0.3–12V AC DC

ELEMENT LENGTH

SWITCH ACTION

FULL ELECTRICAL RATING

3”

CLOSE ON RISE

CF

8.0 A

6.0 A

$128.30

7”

CLOSE ON RISE

CF

8.0 A

6.0 A

132.35

MLP

Limit Types Without Enclosure

SOURCE 1 PART NO.

RANGE (CUT-OUT)

S1-5C02-1

2 150°–250°F 2

S1-5C02-51

2150°–250°F 2

(66°–121° C) (66°–121° C)

DIFFERENTIAL FIXED 25° F (14° C) FIXED 25° F (14° C)

ELEMENT LENGTH

SWITCH ACTION

MOTOR RATING (FULL LOAD) 120V 240V AC AC

FULL ELECTRICAL RATING

VALVES & RELAYS 24V 0.3–12V AC DC

MLP

3”

OPEN ON RISE

CL

10.0 A

6.0 A

4.0 A

1.0 A

$ 88.02

7”

OPEN ON RISE

CL

10.0 A

6.0 A

4.0 A

1.0 A

113.89

1Cut-in 2

point is cut-out setting plus differential for fan controls. Cut-in point is cut-out setting minus differential for limit controls. Tamper resistant screw limits cut-out to 200° F/94° C.

Maxicap Covers Put the lid on call-backs. Not only does the Maxicap prevent regulator lockup due to ice and snow blockage of the vent, it also prevents insects or buildup of mud and debris from clogging the vent.

SOURCE 1 PART NO. S1-MAXICAP3R S1-MAXICAP5R

• • • • • • •

Inexpensive and effective Maintains vent limit protection Fits Maxitrol 325-3 & 325-5 Simple installation No tools required UV Safe Patent pending

DESCRIPTION

MLP

RUBBER WEATHER COVER FITS MAXITROL 325-3 SERIES REGULATORS RUBBER WEATHER COVER FITS MAXITROL 325-5 SERIES REGULATORS

$14.91 20.89

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

129


hemrichelectric.com

info@hemrichelectric.com

HEAT SEQUENCERS ELECTRIC HEATING CONTROLS

Model 24A34 Electric Heat Sequencers • Any contacts (except M1 and M2) can be used as auxiliary contacts. • Double quick-connect terminals for combination loads. • U.L. Component recognized. 24A34-15 Normally Open Contacts 1-3 • Used in heat pump air handler applications. • Provides a delay off to the blower motor in cooling mode. • Single pole double throw.

Direct replacement for most fan/heat sequencind functions. Terminal markings are equivalent to competitive types and allow one wiring method for various sources of sequencers. Features: • Replaces Honeywell, Klixon (Texas Instruments), MARS, TOD, GEMLINE types. • Solid-state reliability. • Ambient rated from -50 to +165°F. • 24V input control. • Multi-poise mounting. Specifications: Electrical Ratings Single Load Contact Ratings (All Models):

VAC 120 240 480

RESISTIVE (NON-INDUCTIVE) WATTS AMPS 3000 6000 6000

MOTOR RATINGS (INDUCTIVE) FULL LOAD LOCKED ROTOR

25.0 25.0 12.5

10.0A (14.0A FOR 24A34-15) 5.0A (7 FOR 24A34-15) 3.0A

PILOT DUTY

60.0A (72 FOR 24A34-15) 30.0A (42 FOR 24A34-15) 18.0A

125 VA 125 VA 480 VA

Combined Load Rating (All Models): 30A @ 240 VAC — TOTAL; 23 A Non-inductive + 7 FLA/42 LRA Inductive. ON TIME — Elapsed time to make contacts after heater is energized (Min. to Max.) OFF TIME — Elapsed time to break contacts after heater is de-energized (Min. to Max.). TIMINGS SOURCE 1 PART NO. S1-24A34-1 S1-24A34-2 S1-24A34-3 S1-24A34-4 S1-24A34-5 S1-24A34-6 S1-24A34-14 S1-24A34-15

TIMINGS

SWITCHES

1 1 1 1 2 2 4 1

1 1 2 2 3 4 5 1

M1-M2

M3-M4

1-20 — — — 1-20** — — 1-110** 1-160**

ON M5-M6

M7-M8

— — 30-90 — — — 30-90** 1-110 — 1-110** 1-160 1-60 (ON 1-3)

M9-M10 — — — — — —

M1-M2

M3-M4

40-110 — — — 40-110** — — 1-110** 1-160**

OFF M5-M6

M7-M8

— 1-30 — 1-30** 1-110 1-110**

— — — —

1-160 75-95 (OFF 1-3)

M9-M10

MLP

— — — — — —

$12.77 13.51 15.21 15.21 22.57 24.57 39.24 34.47

*M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF. †24A34-14 Switch contacts designated F1-F2 instead of M1-M2. **These contacts switch simultaneously Note: Underwriters Laboratories requires a fan interlock circuit to insure the blower remains operating whenever more than one sequencer is used. The fan interlock should be the M1-M2 contacts of the second or third sequencer. All M1-M2 contacts are wired to the blower motor so that any sequencer that is energized will keep the blower ON.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

131


hemrichelectric.com

info@hemrichelectric.com

SNAP DISC LIMIT SWITCHES

White Rodgers Adjustable Snap Disc Fan & Limit Controls • 4 adjustable limit control models replace 10 fixed snap disc models. Accessories: Adapter plates (order separately.): F6-1798 1 per pack.

This adjustable Snap Disc Thermostat allows you to set the temperature set point to match your specific needs which simplifies inventory. Features • 1/4” quick connect terminals are standard. • Reduces inventory while providing coverage for a wide range of temperature applications. • Replaces the majority of fixed disc thermostats now on heating equipment and various appliances. • 2 adjustable fan control models replace 7 fixed snap disc models. Typical Electrical Ratings

SOURCE 1 PART NO. S1-3F05-1 S1-3F05-2 S1-3L05-1 S1-3L05-2 S1-3L05-3 S1-3L05-10 S1-3L05-13 S1-3F05-3 S1-3F05-4 S1-3L05-4 S1-3L05-5 S1-3L05-6

VAC

RESISTIVE (NON-INDUCTIVE)

120 240

25.0 A 25.0 A

MOTOR RATING FULL LOAD LOCKED ROTOR 14.0 A 10.0 A

TEMPERATURE RANGE

DIFFERENTIAL

SWITCH ACTION

90 TO 130° F 140 TO 180° F 135 TO 175° F 175 TO 215° F 210 TO 250° F 135 TO 175° F 250 TO 290° F 90 TO 130° F 140 TO 180° F 135 TO 175° F 175 TO 215° F 210 TO 250° F

20° F 20° F 40° F 40° F 40° F 20° F 40° F 20° F 20° F 40° F 40° F 40° F

SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST

PILOT DUTY

72.0 A 60.0 A

FUNCTION

125 VA 125 VA ACCESSORIES

FAN CONTROLS (CLOSE ON RISE) INCLUDES THERMOSTAT AND TAB-TO-SCREW TERMINALS.

LIMIT CONTROLS (OPEN ON RISE) FAN CONTROLS (CLOSE ON RISE) LIMIT CONTROLS (OPEN ON RISE)

INCLUDES THERMOSTAT, TAB-TO-SCREW TERMINALS, ADAPTER BRACKET AND MOUNTING SCREWS

“THERM-O-DISC” NUMBER

MLP

74T12-310708 74T12-310709 74T11-310710 74T11-310711 74T11-310712 74T11-310724 74T11-310730 74T12-310708 74T12-310709 74T11-310710 74T11-310711 74T11-310712

$28.89 28.89 28.89 28.89 23.80 28.85 23.80 31.24 31.24 31.24 31.24 31.24

Limit Controls—Manual Reset FIXED TEMPERATURE SETTINGS CUT-IN CUT-OUT

SOURCE 1 PART NO. S1-3L02-160 S1-3L02-170 S1-3L02-180 S1-3L02-190 S1-3L02-200

160° F (71° C) 170° F (77° C) 180° F (82° C) 190° F (88° C) 200° F (93° C)

MANUAL RESET

SWITCH ACTION

“THERM-O-DISC” PART NO.

MLP

OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE

60T15-330534 60T15-330535 60T15-330536 60T15-330537 60T15-330538

$16.91 14.77 14.90 16.91 14.30

SPDT Controls FIXED TEMPERATURE SETTINGS TERMINAL 1 & 3 TERMINAL 1 & 2 CUT-OUT CUT-IN CUT-IN CUT-OUT

SOURCE 1 PART NO. S1-3L03-140 S1-3L03-190

140° F (60° C) 190° F (88° C)

120° F (49° C) 170° F (77° C)

140° F (60° C) 190° F (88° C)

120° F (49° C) 170° F (77° C)

SWITCH ACTION

“THERM-O-DISC” PART NO.

MLP

SPDT SPDT

60T13-611015 60T13-611014

$15.72 15.72

Electrical Ratings ELECTRICAL RATING (AC) FOR TYPE NUMBERS 3L01 3L02 3L03

132

1 & 2 CLOSE ON RISE 1 & 3 OPEN ON RISE

MOTOR RATING (FULL LOAD) 120 VAC 240 VAC 10.0 A 10.0 A 5.8 A 10.0 A

STOCKED NON STOCKED

5.0 A 5.0 A 2.9 A 5.0 A

RESISTIVE (NON-INDUCTIVE) 120/240 VAC 277 VAC 25.0 A 25.0 A — 25.0 A

21.6 A 21.6 A — 21.6 A

PILOT DUTY 120/240/277 VAC 125 VA 125 VA 125 VA 125 VA

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

SNAP DISC LIMIT SWITCHES

White Rodgers Snap Disc Fan Controls Types for regulation of fan or blower or for high limit safety control. Features • Designed for quick on-job replacement. • Easy to remember type numbers—”L” for Limit—”F” for Fan. • Last three numbers indicate cut-out temperatures on limits and cut-in temperatures on fan controls.

FIXED TEMPERATURE SETTINGS CUT-IN CUT-OUT

SOURCE 1 PART NO.

• Mounting holes match standard 3/4” snap discs. • Tab-to-screw therminal adaptors furnished.

SWITCH ACTION

“THERM-O-DISC” PART NO.

MLP

90° F (32° C) 110° F (43° C) 115° F (46° C) 120° F (49° C) 130° F (54° C) 140° F (60° C) 160° F (71° C) 180° F (82° C) 320° F (160° C)

CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE CLOSE ON RISE

60T12-610044 60T12-610046 60T12-610047 60T12-610049 60T12-610050 60T12-610064 60T12-610065 60T12-610066 60T12-610067

$10.56 10.56 10.95 10.56 10.95 10.56 10.95 10.95 10.32

120° F (49° C) 130° F (54° C) 140° F (60° C) 150° F (66° C) 165° F (74° C) 170° F (77° C) 180° F (82° C) 190° F (88° C) 200° F (93° C) 230° F (110° C) 250° F (121° C) 300° F (149° C) 350° F (177° C)

OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE OPEN ON RISE

60T11-610000 60T11-61002 60T11-610006 60T11-610009 60T11-610069 60T11-610012 60T11-610013 60T11-610015 60T11-610016 60T11-610021 60T11-610023 60T11-610026 60T11-610068

$10.72 10.72 10.32 10.32 10.32 10.32 10.32 10.32 10.32 10.32 10.32 10.32 10.32

FAN CONTROLS S1-3F01-110 S1-3F01-120 S1-3F01-130 S1-3F01-140 S1-3F01-150 S1-3F01-160 S1-3F01-180 S1-3F01-200 S1-3F01-350

110° F (43° C) 120° F (49° C) 130° F (54° C) 140° F (60° C) 150° F (66° C) 160° F (71° C) 180° F (82° C) 200° F (93° C) 350° F (177° C)

LIMIT CONTROLS—MANUAL RESET S1-3L01-120 S1-3L01-130 S1-3L01-140 S1-3L01-150 S1-3L01-165 S1-3L01-170 S1-3L01-180 S1-3L01-190 S1-3L01-200 S1-3L01-230 S1-3L01-250 S1-3L01-300 S1-3L01-350

110° F (43° C) 115° F (46° C) 100° F (38° C) 110° F (43° C) 125° F (52° C) 130° F (54° C) 140° F (60° C) 150° F (66° C) 160° F (71° C) 190° F (88° C) 210° F (99° C) 250° F (121° C) 310° F (154° C)

SPECIFICATIONS Electrical Ratings MOTOR RATING (FULL LOAD)

RESISTIVE (NON-INDUCTIVE)

MODEL

120VAC

240VAC

120/240VAC

277VAC

PILOT DUTY 120/240/ 277VAC

3F01, 3F02

10.0A

5.0A

25.0A

21.6A

125 VA

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

133


hemrichelectric.com

info@hemrichelectric.com

OIL BURNERS OIL HEATING CONTROLS

Beckett Model AFG Oil Burner

Specifications: Capacities - Model AFG 0.75 to 2.00 gallons per hour 56,000 to 420,000 BTU/hr input

Fuels No. 1 or No. 2 Heating Oil (ASTM D396) only Dimensions (standard) Height: 11-1/2" Width: 12-7/8" Depth: 6-9/16" (chassis only) Electrical Characteristics Motor: 3450 RPM, NEMA M-Flange, manual reset overload protection Power Supply: 120 V./60 Hz./1 phase Ignition: 10,000 V. 23 ma. secondary, continuous duty shielded transformer Operating Load: 5.8 amps (maximum) Fuel Unit Single Stage Or Two Stage Special Features The model AFG oil burner builds on the timetested design of the popular AF burner. The AFG adds an Air Turbo Injector and a high efficiency blower wheel to the field-proven basic AF burner. Inside the burner housing, the spe-

cially designed Air Turbo Injector channels combustion air for extra smooth starts and minimal pulsation to enhance operating efficiency and minimize air noise. The high efficiency blower wheel interacts with the Air Turbo Injector to create high static pressure firing under any draft condition. This capability makes the AFG the ideal choice for firing positive pressure heating appliances and for overcoming poor chimney design conditions. The firing range of this versatile burner is 0.75 to 2.00 gallons per hour. The AFG accepts Beckett’s standard flameretention heads, air tube combinations, pedestals, flanges and other accessory parts. The air tube combinations feature secondstage air introduction to complete and optimize combustion, and a unique design that allows the installer to make precise adjustments. The result is a clean, compact flame and peak burner performance.

Flame Retention Heads

SOURCE 1 PART NO.

S1-02633080700

MODEL NO.

YK201

AIR TUBE NO.

S1-02633077700 (AF47YH FS)

HEAD

S1-02633075700 (F3)

AIR AIR STATIC SHUTTER BAND PLATE SETTING SETTING 4

0

5

0

7

0

9

0

3-3/8

RECOMMENDED NOZZLE * (NOT INCLUDED) .50 GPH X 70° SOLID .65 GPH X 70° HOLLOW .75 GPH X 70° HOLLOW .90 GPH X 70° HOLLOW

PUMP STAGE

BONNET CAPACITY

SINGLE

55,000

SINGLE

73,000

SINGLE

85,000

SINGLE

100,000

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

USED W/ FURNACE CONFIGURATION MULTIPOISE, LO-BOY HORIZONTAL, DOWNFLOW MULTIPOISE, LO-BOY MULTIPOISE, LO-BOY

MLP

$1370.80

135


hemrichelectric.com

info@hemrichelectric.com

OIL BURNERS & FUEL PUMPS

Parts For Beckett AFG Oil Burners

ITEM

DESCRIPTION

55,000 BTU

1 2 3 4 5 6 7 9 10 11 14

BURNER MOTOR CADMIUM CELL (SENSOR) ELECTRODES NOZZLE ASSEMBLY CONTROL, PRIMARY/IGNITOR * COUPLING RETENTION HEAD BURNER FLANGE GASKET SINGLE STAGE PUMP TWO STAGE PUMP BLOWER WHEEL

73,000 BTU

85,000 BTU

BONNET CAPACITY 100,000 BTU 125,000 BTU

150,000 BTU

200,000 BTU

S1-02424698700 S1-02526967000 S1-02633069000 S1-02630267000

S1-02633079700 S1-02633072700 S1-02633075700 S1-02633076700 S1-02630266000 S1-52633074001 — S1-02633071700

— — S1-02633311700

MLP $198.67 75.32 21.58 53.67 341.24 5.35 15.36 2.24 149.25 284.28 40.26

* Includes Gasket

OIL NOZZLES

Danfoss Nozzles For AFG Oil Burners Features: • Meets ISO 9001 International standards • Atomizes fuel oil in burners with capacities from .40 GPH to 3.0 GPH

136

• Nozzles stamped with spray pattern, capacity and angle • Atomization pressure is 100 psi

SOURCE 1 PART NO.

DANFOSS PART NO.

CAPACITY GPH

SPRAY ANGLE

CONE SHAPE

MLP

S1-52635397000 S1-52635628000 S1-52635629000 S1-52635630000 S1-52635631000 S1-52635632000 S1-52635398000 S1-52635399000 S1-52635633000 S1-52635624000

030H6514 030H8514 030H6516 030H8516 030H8518 030H6520 030H8520 030H6523 030H8528 030F7529

.65 .65 .75 .75 .85 1.00 1.00 1.20 1.50 1.65

60° 80° 60° 80° 80° 60° 80° 60° 80° 70°

HOLLOW HOLLOW HOLLOW HOLLOW HOLLOW HOLLOW HOLLOW HOLLOW HOLLOW SOLID

$8.68 8.25 7.71 8.25 8.46 7.71 7.71 8.02 7.71 8.02

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

OIL BURNER PROTECTORELAYS

Honeywell R8184G Protectorelay Oil Burner Control

Provides automatic, nonrecycling control of an intermittent ignition oil burner system

APPROVAL BODIES: Component recognized by Underwriters Laboratories Inc. Certified by Canadian Standards Association. APPROXIMATE DIMENSIONS: 4 in. [108 mm] wide, 4 in. [111 mm] high, 2 in. [64 mm] deep. AMBIENT TEMPERATURE RANGE: -40 F to 130 F [-40 C to 54 C]. THERMOSTAT ANTICIPATOR SETTING: 0.2 A. ELECTRICAL RATINGS: Voltage and Frequency – 120 V, 60 Hz.

Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. Solid state flame sensing circuit. LED on terminal strip indicates system lockout. Remote lockout indication available on some models. External button to manually reset safety switch after lockout. Manual trip lever opens safety switch for system maintenance. Mounts on standard 4 x 4 in. junction box or directly on burner housing. C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required.

Load Relay Contacts (A) MOTOR RATING

120 VAC

240 VAC

FULL LOAD LOCKED ROTOR

7.4 44.4

3.7 22.2

Ignition Rating – 360 VA (in addition to above motor rating). SOURCE 1 PART NO. S1-R8184G1286

SAFETY SWITCH TIMING

MLP

45 SECONDS

$155.60

R8184M Protectorelay Oil Burner Control

Provides control of an intermittent ignition oil burner and power for a low voltage cooling control circuit.

APPROVAL BODIES: Component recognized by Underwriters Laboratories Inc. APPROXIMATE DIMENSIONS: 6” [152 mm] H, 4” [121 mm] W, 2” [64 mm] D. AMBIENT TEMPERATURE RANGE: 32°F to 115°F [0°C to 46°C]. ELECTRICAL RATINGS: Transformer – 40 VA. Primary voltage – 120 V, 60 Hz; secondary voltage (open circuit) – 27 V, 60 Hz. Ignition is on whenever the burner is on (intermittent ignition — also called constant ignition).

Solid state flame sensing circuit. External button to manually reset safety switch after lockout. Enclosed safety switch must be manually reset after safety shutdown. Y and G terminals for connection of cooling equipment. Integral 40 VA transformer. Mounts on standard 4” x 4" junction box. C554A Cadmium Sulfide Flame Detector and a 24 VAC thermostat required.

Load Contacts (A) MOTOR RATING

120 VAC

240 VAC

FULL LOAD LOCKED ROTOR

7.4 44.4

3.7 22.2

Ignition rating – 360 VA (in addition to above motor rating). Power Consumption – 6.5 W running.

SOURCE 1 PART NO. S1-R8184M1002 S1-R8184N1009

SAFETY SWITCH TIMING

THERMOSTAT ANTICIPATOR SETTING

MLP

45 SECONDS 45 SECONDS

0.2 AMPS 0.2 AMPS

$227.11 137.66

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

137


hemrichelectric.com

info@hemrichelectric.com

CAD CELL RELAYS & FLAME DETECTORS

White Rodgers 668 Series Kwik-Sensor Cad Cell Relays

Replaces intermittent ignition Kwik-Sensor Cad cell relays on oil burner systems with 15, 30 or SOURCE 1 PART NO. S1-668-401 S1-668-430 S1-668-451 † S1-668-454 S1-668-501 S1-668-601

SAFETY TIMING

THERMOSTAT TYPE

45 SEC. 45 SEC. 45 SEC.

2-WIRE 2 OR 3 WIRE * 2-WIRE

30 SEC. 15 SEC.

2-WIRE 2-WIRE

45 second safety timing. Certain types have unique Signal-Lite feature which glows whenever safety lockout occurs. Features: • Grey enclosure. • 120 VAC, 60 Hz standard input voltage • 24 VAC control voltage. • Full 10 FLA, 60 LRA, 120 VAC rating on motor relay contacts. • Ignition transformer rating 360 VA (3.0A). • 10” useable leads. THERMOSTAT ANTICIPATOR SETTING

SAFETY LOCK-OUT LIGHT

MANUAL LOCK-OUT LEVER

• Mounts to 4” x 4” junction box. • Line voltage safety switch eliminates burner run-on in event motor relay contacts weld closed. • Solid state flame detection circuitry is not affected by vibration or high or low ambient temperatures. Suitable for use from -40 to 150° F (-40 to 66° C). • Screw terminals for low voltage connections provide positive contact. • Recycles upon momentary flame failure or power interruption. TIME START FAN SWITCH

INTEGRAL TRANSFORMER

0.4A NO NO NO 0.4A YES YES NO 0.4A NO NO 40VA SAME AS 668-451 EXCEPT HAS EXTRA Y AND G TERMINALS. 0.4A NO NO NO 0.4A NO NO NO

NO F*-B C-W NO NO

MLP $139.61 206.75 231.43 197.69 157.14 188.46

* 3-wire series 10. † Models with external transformer have safety switch contacts in motor relay (low voltage) circuit.

White Rodgers Flame Detectors Solid state electronic flame detector which utilizes light intensity to sense the presence of a flame in oil burning heating equipment.

SOURCE 1 PART NO. S1-956-154

DESCRIPTION

MLP

UNIVERSAL FLAME DETECTOR WITH 6 BRACKETS. 60” LEADS.

$37.81

Honeywell R8991 Interrupted Ignition Recycle Oil Primary and Ignitor

Consists of interrupted ignition oil primary, solid state ignition source and cad cell flame sensor; operates oil burner and oil valve (if desired) in response to a call for heat. ELECTRICAL RATINGS: Input – 120 VAC, 60 Hz. Output – Burner Motor Contacts: 7.4A full load, 44.4A locked rotor. THERMOSTAT LOAD: 0.2A. SOURCE 1 PART NO. S1-02639217000

138

LOCKOUT TIMING 45 SECONDS

INDICATOR LIGHT: On – the cad cell is sensing flame. Off – the cad cell is not sensing flame. Flashing ( sec. on) – the system is locked out. Flashing (2 sec. on) – the system is in recycle mode. LOCKOUT TIME: 45 seconds. RECYCLE TIME: 60 seconds. IGNITION CARRYOVER TIME: 45 seconds. Single-unit control – primary and ignitor. Mounts directly on oil burner housing. For use on Beckett AF and AFG burners only. Indicator light provides lockout and cad cell indication.

Monitors burner flame and shuts down system on ignition failure (lockout) or on flame failure during the run cycle. Includes manual reset button to reset control after lockout. Includes ignition carryover period – control continues to provide spark after flame is sensed to ensure that the flame remains lit. APPROVAL BODIES: Component recognized by Underwriters Laboratories Inc. Certified by Canadian Standards Association. OPERATING AMBIENT TEMPERATURE: 40°F to +150°F [-40°C to +66°C]. HUMIDITY RATING: 90 percent RH at 95°F [35°C] noncondensing.

INCLUDES

MLP

INTERRUPTED IGNITION OIL PRIMARY, SOLID STATE IGNITION SOURCE, CAD CELL FLAME SENSOR, STATUS INDICATOR LIGHT AND MANUAL RESET BUTTON

$133.28

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

CONTACTORS HVAC COMPONENTS

Type 3100 and 3186 Contactors Features: • Application - power and pilot duty • Insulation class B

SOURCE 1 PART NO. S1-02427531000 S1-02425836700 S1-02425837700 S1-02425839700 S1-02426566700 S1-02425841700 S1-02425840700 S1-02425955000 S1-02425843700 S1-02427520000 S1-02426568700 S1-02425844700 S1-02425845700 S1-02425846700 S1-02425847700 S1-02425848700 S1-02425849700 S1-02425850700 S1-02425851700 S1-02425852700 S1-02425842701 S1-02425843701 S1-02425844701 S1-02425845701 S1-02426569701 S1-02426570701 S1-02425849701 S1-02426571701 S1-02425851701 S1-02426572701 S1-02425852701 S1-02425853700 S1-02425854700 S1-02425853701

VENDOR PART NO.

• All terminals are combination screw & push-on • 50/60 Hz. • Meets device specifications up to 600 VAC per bulletin 508

POLE CONFIG. (NORM. OPEN)

3100Y15Q215 1P - W/SHUNT 3100Y15T215 1P - W/SHUNT 3100Y15Q1915CL 1P - W/SHUNT 3100Y20T615 2P 3100Y20U615 2P 3100Y20T1815CL 2P 3100Y20Q1815CL 2P 42BF35AJAFU 3P 3100Y30T915 3P 3100Y30U915AH 3P 3100Y30U915 3P 3100Y30Q1015CL 3P 3100Y30T1015CL 3P 3100Y30Q1615CL 3P 3100Y30T1615CL 3P 3100Y30Q1715CL 3P 3100Y30T1715CL 3P 3186Y30Q7515CL 3P 3186Y30T7515CL 3P 3186Y30T9015CL 3P 3100Y30Q915HT 3P * 3100Y30T915HT 3P * 3100Y30Q1015HU 3P * 3100Y30T1015HU 3P * 3100Y30U1015HU 3P * 3100Y30U1615CQ 3P * 3100Y30T1715CQ 3P * 3100Y30U1715CQ 3P * 3186Y30T7515CQ 3P * 3186Y30U7515CQ 3P * 3186Y30T9015CQ 3P * 3100Y40T915L 4P 3100Y40T1015CL 4P 3100Y40T915AA 4P *

FLA

CONTACT RATINGS LRA R RTG.

240 480 600 240 480 600 240 480/ V V V V V V V 600 V 30 30 40 30 30 40 40 30 30 30 30 40 40 50 50 60 60 75 75 90 30 30 40 40 40 50 60 60 75 75 90 30 40 30

30 30 40 30 30 40 40 30 30 30 30 40 40 50 50 60 60 75 75 90 30 30 40 40 40 50 60 60 75 75 90 30 40 30

30 30 40 30 30 40 40 30 30 30 30 40 40 50 50 60 60 75 75 90 30 30 40 40 40 50 60 60 75 75 90 30 40 30

150 150 240 150 150 240 240 180 180 180 180 240 240 300 300 360 360 450 450 540 180 180 240 240 240 300 360 360 450 450 540 180 240 180

75 75 200 125 125 200 200 150 150 150 150 200 200 250 250 300 300 375 375 450 150 150 200 200 200 250 300 300 375 375 450 150 200 150

50 40 50 40 160 50 100 40 100 40 160 50 160 50 120 40 120 40 130 40 130 40 160 50 160 50 200 65 200 65 240 75 240 75 300 93 300 93 360 120 120 40 120 40 160 50 160 50 160 50 200 65 240 75 240 75 300 93 300 93 360 120 130 40 160 50 130 40

40 40 50 40 40 50 50 40 40 40 40 50 50 65 65 75 75 93 93 120 40 40 50 50 50 65 75 75 93 93 120 40 50 40

• Panel mounted • Dimensions are maximum • Box lug power terminal (L)

COIL DATA

VTS.

HZ

24 120 24 120 208/240 120 24 24 120 208/240 208/240 24 120 24 120 24 120 24 120 120 24 120 24 120 208/240 208/240 120 208/240 120 208/240 120 120 120 120

50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60

MAX MAX INRUSH SEALED INS. VA VA CLASS 50/60 50/60 B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B

23/22 26/24 23/22 40/37 40/37 40/37 38/35 52 55/52 58/55 58/55 55/52 55/52 135/125 135/125 135/125 135/125 325/270 325/270 325/270 55/52 55/52 55/52 55/52 58/55 135/125 135/125 135/125 325/270 325/270 325/270 68/60 68/60 68/60

9/6.5 9/7 9/6.5 10/8 10/8 10/8 10/8 6.2 11/9 11/9 11/9 11/9 11/9 19/14 19/14 19/14 19/14 38/25 38/25 38/25 11/9 11/9 11/9 11/9 11/9 20/14 19/14 20/14 38/25 38/25 38/25 14/9 14/9 14/9

WIRE SIZE M M A I DWG. X N NO. 8 8 4 8 8 4 4 2 8 8 8 4 4 2 2 2 2 1/0 1/0 1/0 8 8 4 4 4 2 2 2 1/0 1/0 1/0 8 4 8

16 16 14 16 16 14 14 14 16 14 16 14 14 14 14 14 14 14 14 14 16 16 14 14 14 14 14 14 14 14 14 16 14 16

1 1 1 2 2 3 3 5 4 4 4 4 4 5 5 5 5 6 6 6 4 4 4 4 4 5 5 5 6 6 6 7 7 7

MLP $ 19.83 16.57 24.08 14.20 21.27 26.18 23.39 43.73 40.65 52.01 36.54 49.11 45.87 97.16 109.30 110.48 123.99 278.22 272.99 380.78 48.53 50.01 63.87 73.38 58.87 117.80 142.26 145.44 272.82 294.13 379.01 81.52 94.38 103.92

* Indicates Auxiliary Contacts (1) Normally Open (NO), (1) Normally Closed (NC), Rated 10A @ 115 - 600 Volts.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

139


hemrichelectric.com

info@hemrichelectric.com

CONTACTORS

Source 1 Definite Purpose Contactors

SOURCE 1 PART NO.

POLES

S1-DP130024 S1-DP230024 S1-DP230120 S1-DP230240 S1-DP240024 S1-DP240120 S1-DP240240 S1-DP330024 S1-DP330120 S1-DP330240 S1-DP340024 S1-DP340120 S1-DP340240

1 2 2 2 2 2 2 3 3 3 3 3 3

AMPS

VOLTAGE 24

30

40

30

40

120 240 24 120 240 24 120 240 24 120 240

MLP $ 9.50 11.57 11.57 11.57 15.61 15.61 15.61 24.96 24.96 24.96 25.54 25.54 25.54

Honeywell Deluxe PowerPro DP-Series Definite Purpose Contactors—2 Pole Definite purpose one (25A, 30A, 40A) and two (20A, 30A, 40A) pole contactors provide switching for across-the-line starting of inductive motors. Features: • Meets ARI-780 Standard at started ratings (500,000 cycle mechanical life, 200,000 cycle electrical life and 10,000 cycle recycle life); the most demanding ARI requirement. • Silver cadmium oxide contacts provide long life under demanding duty cycles.

DP2030A5012 SOURCE 1 PART NO. S1-DP2030D5001 S1-DP2030A5012 S1-DP2030B5011 S1-DP2030C5010

140

• Low profile design allows for more wiring room. • Multiple mounting holes and slots for convenient, interchangeable mounting with most competitive devices. Specifications: Approvals: UL Component Recognized: File number E597 Guide number NLDX2 CSA Certified: File number LR95329-A224 Electrical Connections (main): sems screws

DP2030B5011

Contact Connections (coil): 1/4” quick-connects Electrical Ratings, Contacts (AFL @ 240 VAC & 277 VAC): 30 A @ 240/277 VAC Poles: 2 Temperature Ratings: –4° to +149° F (–20° to +65° C)

DP2030C5010

DP2030D5001 DIMENSIONS (IN.) W D

COIL RATINGS VOLTAGE (V)

ELECTRICAL RATINGS, CONTACTS (RESISTIVE @ 240 VAC & 277 VAC)

H

277 VAC 24 V 120 V 208/240 V

48 A @ 240/277 VAC 48 A @ 240/277 VAC 48 A @ 240/277 VAC, 480 VAC, 600 VAC 48 A @ 240/277 VAC, 480 VAC, 600 VAC

2-3/16 3-1/4 2-3/16 2-3/16

STOCKED NON STOCKED

2-1/2 2-5/8 3-5/16 2-1/2

3-5/16 3-3/4 2-5/32 3-5/16

MLP $30.72 41.30 34.76 34.76

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

FAN RELAYS

Source 1 Enclosed Fan Relays 90-290Q thru 90-295Q WR/RBM Type 84 Relays are totally enclosed. Relay comes single pole normally open or single pole double throw. Used for switching single or two speed fan motors, solenoids, relays, resistive loads and general purpose switching. Features: • Temperature range: –40°F to 150°F • Mechanical life (no load): 1,000,000 operations, 60 operations per minute • Electrical life (rated load): • 100,000 operations, 6 operations per minute • Load test making inrush rating (0.4 to 0.5 P.F.); breaking 100% continuous rating (0.64 to 0.8 P.F.) Single Pole Single Throw Normally Open (SPST-NO) SOURCE 1 PART NO.

COIL VOLTAGE (50/60 HZ)

• Weight (approximate): 2.5 oz. • U.L. File No.: E12139 or E22381 • C.S.A. File No.: LR13360 Coils: • Frequency: 50/60 Hz • Class Insulation: B • Termination: 1/4” quick connect • Operate: 85% of niminal voltage; 110% maximum safe operate • Duty Cycle: continuous

MLP

S1-S90-290Q 24 $9.46 S1-S90-291Q 120 9.46 S1-S90-292Q 240 9.46 *Can be used as an isolation relay for digital thermostats when required.

Single Pole Double Throw (SPDT) SOURCE 1 PART NO.

COIL VOLTAGE (50/60 HZ)

MLP

24 120 240

$9.82 9.82 9.82

S1-S90-293Q S1-S90-294Q S1-S90-295Q CONTACT RATING 125/250 VAC INDUCTIVE RESISTIVE 8 AMPS CONTINUOUS 25 AMPS INRUSH

16 AMPS CONTINUOUS

Wiring Diagrams

Cross Reference Guide MARS NO.

SOURCE 1 PART NO.

ALTERNATE SOURCE 1 NO.

90290 90291 90292 90293 90294 90295

S1-90-290Q S1-90-291Q S1-90-292Q S1-90-293Q S1-90-294Q S1-90-295Q

S1-90-360 S1-90-362 S1-90-364 S1-90-370 S1-90-372 S1-90-374

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

141


hemrichelectric.com

info@hemrichelectric.com

FAN RELAYS

Source 1 Heavy-Duty Enclosed Fan Relays 90-360 Thru 90-484 WR/RBM Type 184

CONTACT RATING INDUCTIVE RESISTIVE 14 AMPS CONTINUOUS 84 AMPS INRUSH @ 125 VAC 8 AMPS CONTINUOUS 48 AMPS INRUSH @ 250 VAC 7 AMPS CONTINUOUS 42 AMPS INRUSH @ 277 VAC

25 AMPS CONTINUOUS @ 277 VAC

When you need a compact, totally enclosed relay with 50% more electrical rating, (14 A.) that’s quiet on the job ... Select the Source 1 90-370 Series. This heavy duty general purpose relay operates in any position, plus enclosed design minimizes exposure to, and damage from, elements. Plugs into receptacles. All good reasons to reach for Source 1. The 90-370 Series is built to do a variety of jobs quietly, reliably and economically. It is perfect for applications involving: • Air Conditioning • Heating • Appliances • Fan Control • General Purpose Switching Features: • Temperature Range: –40°F to 150°F • Mechanical Life (no load): 1,000,000 operations 30 operations per minute

• Electrical Life (rated load): —100,000 operations, 6 operations per minute —Load test making inrush ratings (0.4 top 0.5 P.F.); breaking 100% continuous rating—(0.65 to 0.8 P.F.) • Weight (approximate): 3 oz. • U.L. File No.: E12139 and E22381 • C.S.A. File No.: LR13360 Coils: • Frequency: 50/60 Hz • Class Insulation: B • Termination: 1/4” quick connect • Operate: 85% of nominal voltage; 110% maximum safe operate • Duty Cycle: continuous

Single Pole Normally Open (S.P.N.O.) SOURCE 1 PART NO. S1-S90-360 S1-90-362 S1-90-364

COIL VOLTAGE (50/60 HZ.)

RES.

NOM. CURRENT MA

24 120 208/240

77 1,800 7,000

125 25 12.5

COIL VOLTAGE (50/60 HZ.)

RES.

NOM. CURRENT MA

24 120 208/240

77 1,800 7,000

125 25 12.5

COIL VOLTAGE (50/60 HZ.)

RES.

NOM. CURRENT MA

24 120 208/240

77 1,800 7,000

125 25 12.5

COIL DATA NOM. VA SEALED 3 3 3

INRUSH VA

MLP

4 4 4

$ 9.82 10.29 11.18

Single Pole Double Throw (S.P.D.T.) SOURCE 1 PART NO. S1-S90-370 S1-90-372 S1-90-374

COIL DATA NOM. VA SEALED 3 3 3

INRUSH VA

MLP

4 4 4

$ 9.82 10.71 11.60

Isolated Contacts (S.P.N.O./S.P.N.C.) SOURCE 1 PART NO. S1-S90-380 S1-90-382 S1-S90-384

COIL DATA NOM. VA SEALED 3 3 3

INRUSH VA

MLP

4 4 4

$ 9.82 10.71 9.82

Wiring Diagrams

142

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

FAN RELAYS

Source 1 2 Pole Switching Relays S1-90-340 thru S1-90-342 WR/RBM Type 91 —Load test making inrush ratings (0.4 to 0.5 P.F.); breaking 100% continuous rating— (0.65 to 0.8 P.F.) • Weight (approximate): 6 oz. • U.L. File no.: E12139 • C.S.A. File No.: LR13360 Coils • Frequency: 50/60 Hz • Class Insulation: B • Termination: 1/4” quick connect • Operate: 85% of nominal coil voltage; 110% maximum safe operate • Duty Cycle: continuous

A two pole double throw semi-enclosed relay. Easy to install and wire. Relay available for power or pilot duty. Suited for vending machines, appliances, fan controls, heating and air conditioning applications and general purpose switching. Features: • Temperature Range:–40°F to 130°F • Mechanical Life (no load): 750,000 operations, 30 operations per minute • Electrical Life (rated load): —100,000 operations, 6 operations per minute

Two Pole Double Throw (2P.D.T.) Fits Receptacles SOURCE 1 PART NO.

COIL DATA

COIL VOLTAGE (50/60 HZ)

TERMINALS 1-2-3

TERMINALS 4-5-6

DC RES.

MA

NOM. VA

INRUSH VA

MLP

24 110/120 208/240

POWER POWER POWER

POWER POWER POWER

15 400 1415

334 66 38

8 8 8

22 22 22

$11.96 11.96 11.96

S1-S90-340 S1-S90-341 S1-S90-342

CONTACT RATING (PER POLE) POWER INDUCTIVE RESISTIVE

A.C. VOLTAGE

13.8 A 1/2 H.P. 13.8 A FULL LOAD 82.8 A INRUSH 1/2 H.P. 6 A FULL LOAD 35 A INRUSH 15 A @ 75% P.F. (POWER FACTOR)

125

250 277

PILOT INDUCTIVE RESISTIVE

15 A

1/10 H.P. 125 V.A.

3A

15 A

1/10 H.P. 125 V.A.

3A

15 A

3A

CONTACT TERMINAL ARRANGEMENT MOUNTING HOLE SIDE COIL TERMINALS SIDE

N.C. = Normally Closed

N.O. = Normally Open

Honeywell General Purpose Relay with DPDT switching

Provide general purpose switching for refrigeration and air conditioning equipment, appliances, vending machines and similar applications.

SOURCE 1 PART NO. S1-R8222V1003

Features: • Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation. • Untaped coil assures cooler operation. • Laminated magnet construction for higher efficiency. • Base designed for easy replacement of competitive relays. • Double quick-connect coil terminals. • Plug compatible with Steveco 90-340 and Mars 90340. Specifications: Electrical Ratings, Contacts (resistive): 10 A @ 480 VAC; 20.8 A @ 120 VAC, 208 VAC, 240 VAC, 277 VAC

SWITCHING

COIL RATINGS (VOLTAGE)

FREQUENCY

480 VAC

FULL LOAD 208, 240, 277 VAC

DPDT

24 VAC

60 HZ; 50 HZ

3A

6A

Pilot Duty Ratings Minimum: 3 VA @ 24 VAC, 120 VAC, & 480 VAC; Maximum: 25 VA @ 24 VAC, 125 VA @ 120 VAC, 240 VAC, & 480 VAC; Resistive: 3 A @ 277 VAC (0.75 power factor); Powerpile: (Normally Open Contacts Only) 0.25 A @ 0.25 to 12 Vdc Dimensions (in.): 1-7/8”H x 2-5/32”W x 2-3/ 8”D Dimensions (mm): 48 mm H x 55 mm W x 60 mm D. Temperature Ratings (F): -20°F to +155°F Temperature Ratings (C): -29°C to +68°C Approvals, Underwriters Laboratories Inc UL Listed: File No. E59779, Guide No. NLDX2 Approvals, Canadian Standards Association Certified: File No. LR35066, Guide No. 184-N-13.13

ELECTRICAL RATINGS LOCKED ROTOR 208, 240, 277 120 VAC 480 VAC VAC 120 VAC 12 A

18 A

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

35 A

60 A

MLP $33.53

143


hemrichelectric.com

info@hemrichelectric.com

FAN RELAYS

Honeywell Fan Relay with SPDT Switching

Provide general purpose and heavy duty switching for refrigeration and air conditioning

SOURCE 1 PART NO.

SWITCHING

S1-R8225A1017

COIL RATINGS (VOLTAGE)

SPDT

Specifications: Electrical Ratings, Contacts (resistive): N.O. 8.0 A, N.C. 7.0 A, Aux. 2.0 A @ 240 VAC; N.O. 16.0 A, N.C. 14.0 A, Aux. 3.0 A @ 120 VAC Dimensions (in.): 2-11/16”H x 2-1/2”W x 3-7/16”D Dimensions (mm): 68 mm H x 64 mm W x 87 mm D Temperature Ratings (F): 115°F Temperature Ratings (C): 46°C Approvals, Underwriters Laboratories Inc UL Listed: File No. E14480, Vol. 1. Sec. 3, Guide No. NLDX Approvals, Canadian Standards Association Certified: File No. LR95329-1 Approvals: CE Approved

equipment, appliances, vending machines and similar applications. Features: • Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation. • Untaped coil assures cooler operation. • Laminated magnet construction for higher efficiency. • Base designed for easy replacement of competitive relays. • Double quick-connect coil terminals. • Plug compatible with Steveco 90-340 and Mars 90340.

FREQUENCY

24 VAC

ELECTRICAL RATINGS FULL LOAD LOCKED ROTOR 240 VAC 120 VAC 240 VAC 120 VAC N.O. 8.0 A N.C. 7.0 A AUX. 2.0 A

60 HZ

N.O. 14.0 A N.C. 14.0 A AUX. 3.0 A

N.O. 48.0 A N.C. 42.0 A AUX. 12.0 A

N.O. 84.0 A N.C. 84.0 A AUX. 18.0 A

MLP $84.97

Products Unlimited Type 38 Start Relays Features: • UL & CSA listed • Non-positional • Instructions & wiring diagram included with each relay • Totally enclosed construction

SOURCE 1 PART NO. S1-02426562700

• Temperature range: –40° F to 150° F • .250 male quick connect push-on terminals • 35 Amp contact rating • Medium torque start application

PRODUCTS UNLIMITED PART NO.

CONTINUOUS COIL VOLTAGE 60HZ

38YA091C015

495

PICK-UP MIN MAX 325

345

DROP OUT MAX.

MLP

135

$33.07

Potential Relays Type 128000 Universal Bracket Features: • Replaces thousands of OEM models • Universal break-off bracket for mounting flexibility • Guide to replace GE, RBM and other Steveco 90-#s included with each relay Specifications: Temperature Range: –40°F to 130°F Mechanical Life (no load): 500,000 operations, 60 operations/min. SOURCE 1 PART NO. S1-90-66 S1-90-71

144

PICK-UP

Electrical Life (rated load): Meets U.L. and ARI specifications Weight (approximate): 6.5 oz. Class Insulation: Class B Duty Cycle: Continuous Approvals: U.L. file number SA1984; C.S.A. file number LR13360

MARS NUMBER

CONTINUOUS COIL VOLTAGE

MIN.

MAX.

DROP OUT MAX.

DC RES.

MA

COIL DATA NOM. VA

INRUSH VA

MLP

19005 19010

395 420

208 223

239 252

130 150

7147 10000

12.7 12.0

5 5

10 10

$17.65 17.65

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TRANSFORMERS

Honeywell Voltage Control

Provide low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or heating-cooling circuits.

SOURCE 1 PART NO. S1-R8239B1076

Features: • NEMA standard Type D transformer (included) powers low voltage control systems. • Provide overload protection for transformer. • Convenient connections for thermostat, and heating-cooling equipment wiring. • Mount on standard 4 x 4 junction box. • Can be mounted in any indoor location without additional enclosure. • Relay is easily replaced without disturbing wiring. Specifications: Application: For system with F50 Electronic Air Cleaner humidifier and blower motor.

ELECTRICAL RATINGS FULL LOAD LOCKED ROTOR 120 VAC 240 VAC 120 VAC 240 VAC

W 12 W MAXIMUM

12 A

6.9 A

72 A

41.4 A

Voltage: 120 VAC; 240 VAC; 208 VAC Switching Action: DPDT Horsepower: 3/4 HP Dimensions (in.): 4-1/2”H, 4-3/16”W, 3-3/32”D Dimensions (mm): 114 mm H, 106 mm W, 79 mm D Approvals, Underwriters Laboratories Inc: UL Listed Approvals, Canadian Standards Association: Certified Approvals, NEMA Standard: NEMA Standard DC20-1992

COIL RATINGS INRUSH SEALED MAX NOM MAX NOM 20 VA

17 VA

10 VA

9 VA

VAC 50 VA

POWER SUPPLY SECONDARY 26.5 V

MLP $116.88

Products Unlimited Transformers 277V = Brown 240V = Orange 480V = Black with Red Tracer

Features: • NEMA class II • UL recognized • Low heat rise • Color coded leads as follows: Common = Black 120V = White 208V = Red SOURCE 1 PART NO. S1-02530889000

PRODUCTS UNLIMITED PART NO. 4000Y01E07AE15

VA RATING 40

VOLTAGE PRI SEC 120

24

HZ 50/60

INS. CL B

FEATURES

MLP

LAY DOWN TYPE, INHERENTLY LIMITED

$22.63

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

145


hemrichelectric.com

info@hemrichelectric.com

TRANSFORMERS

Source 1 Class 2 Transformers 90-T40S1 thru 90-T75C3 24 Volt Secondary Class 2 Transformers Energy Limiting

S1-T2401F

Class 2 transformers are used for industrial, heating and air conditioning controls applications. U.L. File # E2334. CSA # LR-16094.

Air conditioning, heating and refrigeration replacements. Foot mounted—4” x 4” plate—conduit hub. Source 1 multi-mounting control transformers are designed especially for the air conditioning market. The 24 volt output of the transformer assures the operation of valves, relays and contactors under most low voltage conditions, eliminating call backs due to brown outs.

S1-T3403M

Foot-Mount (Open Construction). SOURCE 1 PART NO. S1-T2401F S1-T2403F S1-T2404F

MARS PART NO.

JARD PART NO.

VA

HZ

PRIMARY

CONNECTIONS

SEC.

CONNECTIONS

MLP

50352 50353 50354

4011F 4021F 4031F

40 40 40

60 50/60 60

120V 208/240V 120/208/240V

LEADS LEADS LEADS

24V 24V 24V

LEADS LEADS LEADS

$13.08 14.32 13.83

* Manual reset Multi-Mount (Closed Construction) Universal Mounting With Plate. SOURCE 1 PART NO. S1-T3401M S1-T3403M S1-T3501M S1-T6753 S1-T7752

MARS PART NO.

JARD PART NO.

50302 50303 50304 50314

4011M 4021M 4031M 5031M

VA

HZ

PRIMARY

CONNECTIONS

SEC.

CONNECTIONS

MLP

40 40 50 75 75

50/60 50/60 50/60 50/60 50/60

120V 120/208/240V 120/208/240V 120/208/240/480V 120/208/240/480V

LEADS LEADS LEADS LEADS

24V 24V 24V 24V 24V

LEADS LEADS LEADS LEADS

$18.20 18.23 18.91 30.60 32.86

Source 1 Transformer Lead Color Coding PRIMARY SIDE COMMON WHITE

146

120V BLACK

208V RED

SECONDARY SIDE 240V ORANGE

COMMON YELLOW

STOCKED NON STOCKED

24V YELLOW

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TRANSFORMERS

Steveco Fan Control Centers

A one package transformer and relay combination, for remote mounting. They incorporate the over/under bobbin wound energy-limiting class

2 transformer and fan relay on a common plate for mounting on a standard four inch junction box. For use in remote control circuits: • Furnace and air conditioners • Operation of relays, contactors and solenoids • Temperature indicating and regulation equipment Ease of installation • Line voltage connections pre-wired • Color coded pre-stripped leads TRANSFORMER

PRIMARY SOURCE 1 PART NO.

MARS NO.

VOLTAGE

S1-90-112

24010

120

S1-90-118E

24012

120

24013

120

S1-90-113

*

SECONDARY

CONN.

VOLTAGE 24V

COLOR CODED LEADS, PRE-STRIPPED

24V 24V

CONN.

RELAY

TERMINAL BOARD WITH 5 SCREW TERMINALS

DPDT SPNO/ SPNC SPDT

• Low voltage connections on terminal board

CONTACT RATINGS 120 VAC (AMPS) 240 VAC (AMPS) FULL LOCKED FULL LOCKED LOAD ROTOR LOAD ROTOR 13.8

82.8

6.9

41.4

MLP $63.43

13.8

82.8

6.9

41.4

48.17

13.8

82.8

6.9

41.4

44.05

* Can be used as an isolation relay/transformer for multi-stage digital thermostats when required.

Honeywell R8239 Control Center Include NEMA standard transformer for excellent voltage control. Provide low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or heating-cooling circuits. Features: • NEMA standard Type D transformer (included) powers low voltage control systems. • Provide overload protection for transformer. • Convenient connections for thermostat, and heating-cooling equipment wiring. • Mount on standard 4 x 4 junction box. • Can be mounted in any indoor location without additional enclosure.

• Relay is easily replaced without disturbing wiring. • Includes relay enclosures. Specifications: Applications: For system with F50 Electronic Air Cleaner humidifier and blower motor. Includes: R8222D Approvals: NEMA Standard DC20-1992, UL listed, CSA Certified. Dimensions: 4-1/2”H x 4-3/16”W x 3-3/32”D (114 mm H x 106 mm W x 79 mm D) Electrical Ratings (W): 12 W maximum Horsepower: 3/4 hp @ 120 VAC, 3/4 hp @ 240 VAC

S1-R8239B1043 SOURCE 1 PART NO.

POWER SUPPLY PRIMARY VA SECONDARY

S1-R8239B1043

120 V

S1-R8239B1076

120 VAC, 208 VAC, 240 VAC

40 VA 50 VA

26.5 V 26.5 V

FULL LOAD 120 VAC 240 VAC 12 A 12 A

6.9 A 6.9 A

LOCKED ROTOR 120 VAC 240 VAC 72 A 72 A

41.4 A 41.4 A

SWITCH ACTION

COIL RATINGS INRUSH SEALED

DPDT

10 VA MAXIMUM 9 VA NOMINAL

$ 95.56

DPDT

20 VA MAXIMUM, 17 VA NOMINAL

10 VA MAXIMUM, 9 VA NOMINAL

116.88

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

MLP

20 VA MAXIMUM 17 VA NOMINAL

147


hemrichelectric.com

info@hemrichelectric.com

TRANSFORMERS

Honeywell R8285B Control Center The R8285 Control Center provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or airconditioning systems. DPDT switching allows Total Comfort application with electronic air cleaner, humidifier and blower motor. Specifications: Transformer Ratings: Power Rating: 40 or 50 VA Primary Voltage: Either 120, 208/240 or 120/ 208/240 VAC. Dimensions: 4-1/2”H x 4-3/16”W x 3-5/8”D (114mmH x 106mmW x 92mmD)

S1-R8285B1053 SOURCE 1 PART NO.

REPLACEMENT CONTACT RATING RELAY AFL ALR

S1-R8285B1053

R8222D

12

60

INPUT VOLTAGE 120, 208/240 OR 120/208/240

Leadwire Color Codes (DPDT Switching): Pole 1: Black—Common, Red—N.O. Contact, Brown—N.C. Contact Pole 2: Violet—Common, Red/Yellow—N.O. Contact, Yellow—N.C. Contact Mounting: standard 4” square junction box Approvals: UL Listed, File No. E113671; CSA File No. LR85839

FULL LOAD LOCKED ROTOR 120 VAC 208/240 VAC 120 VAC 208/240 VAC 12 A

6A

60 A

35 A

COIL RATINGS INRUSH SEALED 20 VA MAXIMUM

9 VA

MLP N/A

R8285B Replaces: HONEYWELL FAN CENTERS R8285A, B, C, E, F R8239A, B, C, E, F R8226A, B, C R8227A, B, C R856B R8102

148

HONEYWELL TRANSFORMERS AT72D AT40 AT30A AT20 AT12

HONEYWELL RELAYS R8222 R8225

WHITE-RODGERS 8A94-51

MARS 24010

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TRANSFORMERS

Standard Transformer

S1-AT72D1692

S1-AT72D1683

ELECTRICAL RATINGS PRIMARY VOLTAGE

SOURCE 1 PART NO.

24V control circuit step-down transformer designed to power any 24V control system, including thermostats, gas valves and relays. Features: • Energy limiting, meets NEMA Standard DC20-1992. Transformer is marked “NEMA Type D.” • Meets “NEC Class 2 not wet, Class 3 wet” and U.L. 1585 requirements. • Mount within proper enclosure. Specifications:

FREQUENCY (HZ)

ELECTRICAL —RATINGS— OUTPUT

ELECTRICAL —RATINGS— SECONDARY VOLTAGE

S1-AT72D1691

208 V, 240 V W/40 VA OUTPUT RATING

50/60

24 V AT 40 VA

26.5 V.O.C.

S1-AT72D1683

120 V

50/60

24 V AT 40 VA

26.5 V.O.C.

Electrical Connections (Primary): 9” (229 mm) lead wires. Electrical Connections (Secondary): (2) screw terminals. Mounting: can be foot-mounted; platemounted on 4”x4”, 4” octagon, or 2”x4” electrical boxes (transformer all above plate or 3/4 above plate); or clampmounted via a junction box knockout. Approvals: UL Component Recognized. CS Certified, N.E.C. Approved.

DIMENSIONS

TEMPERATURE RATINGS

3-7/32”H X 2-7/32”W X 3-1/16”D (81.8 MM H X 56.4 MM W X 77.8 MM D) 3-7/32”H X 2-7/32”W X 3-1/16”D (81.8 MM H X 56.4 MM W X 77.8 MM D)

–20ºF TO +105ºF –29ºC TO +41ºC –20ºF TO +105ºF –29ºC TO +41ºC

MLP $54.49 44.57

Honeywell Foot Mounted 120/208/240 VAC Transformer With 9" Lead Wires and Metal End Bells be used in any application that does not exceed the listed ratings. Features: • Rated at 40 VA. • Color-coded leadwires for primary connections and screw terminals for secondary connections, fixed 1/4 inch (6 mm) male quickconnects or color-coded leadwires for both primary and secondary, are standard. • Meet NEC Class 2 requirements. Meet Underwriters Laboratories Inc. Standard UL 1585 and are identified. Class 2 not wet, Class 3 wet.

Provide power to 24 VAC circuits in heating/ cooling control systems. Intended for use in systems with predictable, uniform loads. Can

SOURCE 1 PART NO. S1-AT140A1018

PRIMARY VOLTAGE

FREQUENCY 60 HZ

ELECTRICAL RATINGS SECONDARY VOLTAGE

120 VAC, 208 VAC, 240 VAC

27 V.O.C.

Specifications: Mounting Foot mounted, plate mounted on 2” x 4" or 4” x 4" outlet box, clamp mounted using outlet box knockout, or panel mounted Dimensions (in.): 3-3/16”H x 2-3/8”W x 3-1/8”D Dimensions (mm): 81 mm H x 60 mm W x 79 mm D Temperature Ratings (F): –20°F to +105°F Temperature Ratings (C): –29°C to +41°C Approvals, Underwriters Laboratories Inc UL Listed: A,C,F models. File # E14881 Approvals, Canadian Standards Association CSA Certified: A & B models. ELECTRICAL CONNECTIONS

OUTPUT

PRIMARY

SECONDARY

MLP

24 VAC AT 40 VA

9 IN. LEADWIRES (229 MM)

2 SCREW TERMINALS

$28.25

Honeywell Foot Mounted 120 VAC Transformer With 9" Lead Wires

Power a 24V control system; for direct mounting, or horizontal or vertical foot-mounting. Features: • Channel frame mounting feet and slots allow for the three mounting positions. • Color-coded leadwires for primary connections. Overload protection provided.

• Energy limiting, meet NEMA DC20-1992 Standard. Marked NEMA Type D. Meet NEC Class 2 not wet, Class 3 wet and U.L. 1585 requirements. • Mount within proper enclosure. Specifications: Mounting Channel Frame Mounting allows for Direct, Horizontal, or Vertical Foot mounting. NEMA Rating: NEMA type D Electrical Connections (Primary)(in.): 9" color coded primary and secondary leadwires Electrical Connections (Primary)(mm): 229 mm color coded primary and secondary leadwires

SOURCE 1 PART NO.

FREQUENCY

PRIMARY VOLTAGE

S1-AT40A1121

60 HZ; 50 HZ

120 VAC

Electrical Connections (Secondary)(in.): 9" color coded primary and secondary leadwires Electrical Connections (Secondary)(mm): 229 mm color coded primary and secondary leadwires. Dimensions (in.): 2-3/32”H x 2-5/8”W x 2-3/16”D Dimensions (mm): 53 mm H x 67 mm W x 56 mm D Temperature Ratings (F): –20°F to +105°F Temperature Ratings (C): –29°C to +41°C Approvals: Underwriters Laboratories Inc UL Component Recognized; Canadian Standards Association Certified

ELECTRICAL RATINGS SECONDARY VOLTAGE OUTPUT 26.5 V.O.C.

24 VAC AT 19 VA

MLP $39.33

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

149


hemrichelectric.com

info@hemrichelectric.com

HARD START DEVICES

Kickstart® Hard Start Devices Features: • Two-wire hard start device using a mechanical potential relay with start capacitor. • No PTCR devices or time delays. • Works on all 208-265 volt PSC & CSIR air conditioning, heat pump and refrigeration compressors; 1-5 HP — Reciprocating, Scroll, and Rotary. • Restarts instantlyTM. • Easy two-wire installation eliminates expensive inventory of multiple potential relays and start capacitors.

SOURCE 1 PART NO. S1-02431994000 S1-02431995000 S1-02432005000 S1-02432069000 S1-02432070000 S1-02432071000

KICKSTART PART NO.

APPLICATION

FIG.

MLP

TO-5 KS1 KS8 KSTS216 KSTS243 KSTS324

1 THRU 3 TON HIGH TORQUE HEAT PUMP & A/C 3.5 THRU 5 TON HIGH TORQUE HEAT PUMP & A/C 1 THRU 3 TON HIGH TORQUE CAPILLARY TUBE & ORIFICE METERING DEVICES 2 & 2.5 TON BRISTOL TS COMPRESSOR 3 TON BRISTOL TS COMPRESSOR 4 & 5 TON BRISTOL TS COMPRESSOR

A B B B B B

$104.30 125.43 98.89 155.33 201.10 209.26

Hard Starts

S1-ICM803

SOURCE 1 PART NO.

S1-ICM805

APPLICATION

1/2–3 HP

S1-ICM810

CAPACITOR

By monitoring the compressor current upon startup, ICM RapidStart® is able to engage the hard start capacitor for precisely the correct amount of time, ensuring maximum starting torque without the risk of supplying too much current into the start winding. A timed safety circuit is provided in the event the motor fails to start within 2 seconds. • Fuse protection Features: • Not affected by voltage or current • Operates from 95–288 VAC fluctuations • Patented current sensing circuitry • Not affected by ambient • Easy, 2-wire installation temperatures • OEM-approved Specifications: • Solid-state circuitry Voltage: 95–288 VAC • Boosts starting torque Maximum Input Voltage: 502 VAC • Disengages upon start Operating Temperature Range: • Recycles instantly (less than 1 -40°C to +65°C second)

REPLACES

NEW

S1-ICM803

88–106 MFD. 330 V

NEW

S1-ICM805

2–5 HP

145–175 MFD. 330 V

NEW

S1-ICM810

3-1/2–10 HP

243–292 MFD. 330 V

KICKSTART: T05, T0-5 SUPCO: SPP-8 SPP-8E KICKSTART: KS1 N/A

MLP

$67.68

77.68 87.50

Wiring Diagram Legend: C = Common Terminal, R = Run Terminal, S = Start Terminal, RC = Run Capacitor, RS = Rapid Start, SC = Start Capacitor Maximum Input Voltage = 502 VAC RMS (maximum run capacitor volts) Input Voltage = Run winding volts + Start winding volts Note: Run capacitor voltage is higher than line voltage

150

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

FAN BLOWER CONTROLS & FAN CONTROL CENTERS

Fan Blower Control

S1-ICM274

S1-ICM273

S1-ICM272

S1-ICM270

Specifications: Voltage: 18–30 VAC S1-ICM277

S1-ICM276

Replaces: SOURCE 1 PART NO. S1-ICM270 S1-ICM272 S1-ICM273 S1-ICM274 S1-ICM276 S1-ICM277 SOURCE 1 PART NO. S1-ICM270

RHEEM 47-22827-01 47,22827-81/82 47-22828-01/02

CARRIER

TEXAS INSTRUMENTS

EMI

ROBERTSHAW

GOODMAN

— —

240000-969 240-1764

HK61GA001 HK61GA003 — —

— — — 47-23619-02 47-23619-03 —

2FD-1

HK51GA003

DESCRIPTION DUAL FUNCTION FAN DELAY TIMER COOLING CONTROL MODULE WITH FAN DELAY CIRCULATING FAN CONTROL FOR HEAT PUMP, A/C AND FORCED AIR SYSTEMS

S1-ICM272 S1-ICM273

— — 457-23619-03 RS100-833-02 —

— — — B13707355

CONTACT RATINGS OR OUTPUT

TIME DELAYS

MLP

HEAT/COOL SPEED N.O.: 20A @ 240 VAC N.C.: 10A @ 240 VAC

BLOWER ON: 30 SEC. BLOWER OFF: 90, 120, 150, 180 SEC.

$115.89

N.O. 20A, N.C.: 10A

BLOWER OFF: 60 SEC.

86.61

OUTPUT: 2A @ 240 VAC

BLOWER OFF: 60 SEC.

40.18

BLOWER OFF: 60 SEC.

89.29

S1-ICM274

MICROPROCESSOR-BASED FAN BLOWER CONTROL

OUTPUT: Y OUT: 1.5A FAN: 2A ELECTRIC HEAT RELAY: 30A @ 240 VAC

S1-ICM276

MICROPROCESSOR-BASED CIRCULATION FAN CONTROL IN GAS/HEAT AND A/C SYSTEMS

OUTPUT: FAN: 20A @ 240 VAC INDUCER FAN: 2A

HEAT ON: 60 SEC. HEAT OFF: 120, 150, 180 SEC. COOL OFF: 60 SEC.

119.46

S1-ICM277

MICROPROCESSOR-BASED CIRCULATING FAN CONTROL IN HEAT PUMP, A/C AND FORCED AIR SYSTEMS

N.O.: 20A, N.C.: 10A

BLOWER ON: 7 SEC. BLOWER OFF: 65 SEC.

66.07

Fan Control Center ICM271 • • • •

Features: • Solid state fan blower • Specifically designed to replace popular gas furnace centers SOURCE 1 PART NO. S1-ICM271

Pin selectable blower delays High power, relay output Dual function fan delay timer Controls the circulating fan in heat pump, A/C and forced air systems • OFF delay purges ducts for residual air • ON delay allows air to reach the proper comfort level prior to energizing the fan

DESCRIPTION FAN CONTROL CENTER

VOLTAGE 18–30 VAC

INPUT FREQUENCY 50/60 HZ

Replaces: ROBERTSHAW 695-100

CONTACT RATINGS

FIXED TIME DELAYS

N.O.: 20A N.C.: 10A

ON: 75 SEC. OFF: 105 SEC.

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

CARRIER 302075-3 CES0110017 CES0110018 HH84AA010 HH84AA011 HH84AA012 HH84AA013 HH84AA020 P771-7002

MLP $115.89

151


hemrichelectric.com

info@hemrichelectric.com

FAN BLOWER CONTROLS & FAN CONTROL CENTERS

Fan Control Center ICM275 Features: • Microprocessor-based fan blower control • Built in humidity relay • Manually adjustable post-purge off delay from 60–240 seconds • Electronic air cleaner output Replaces: Robertshaw 695-101 SOURCE 1 PART NO. S1-ICM275

DESCRIPTION

VOLTAGE

FAN CONTROL CENTER

INPUT FREQUENCY

18–30 VAC

50/60 HZ

OUTPUT CONTACT RATINGS

TIME DELAYS

MLP

20A @ 240 VAC ON HIGH 10A @ 240 VAC ON LOW

ON: 60 SEC. FIXED OFF: 60–240 SEC. ADJUSTABLE

$119.46

Furnace Control Modules Features: 0

0 • Microprocessor-based

0

• Twinning compatible with another ICM board—identical model S1-ICM281

S1-ICM280

S1-ICM282

Replaces: SOURCE 1 PART NO.

GOODMAN

UTEC

TEXAS INSTRUMENTS

WHITERODGERS

S1-ICM281

50T35-730 50T35-743 —

S1-ICM282

S1-ICM280

B1809906/08/10/13/135

1012-933D

41F-5

CARRIER — CESO110057-00/01/02 HK42FZ004/007/ 008/009/011/013/016, 325878-751

Furnace Fan Blower Control SOURCE 1 PART NO.

S1-ICM280

DESCRIPTION

OUTPUTS

TIME DELAYS

MLP

INDUCER FAN OUTPUTS, HOT SURFACE IGNITOR OUTPUT FLAME SENSOR INPUT GAS VALVE OUTPUT 18–30 VAC

FAN: 2 HP @ 240 VAC INDUCER FAN: 7A @ 250 VAC GAS VALVE: 1A @ 24 VAC IGNITOR: 5A @ 120 VAC

HEAT ON: 30 SEC. HEAT OFF: 90, 120, 150 SEC. COOL OFF: 60 SEC.

$205.36

Gas Valve, Ignitor, Blower Motor, Inducer, Humidifier & Air Cleaner Controls SOURCE 1 PART NO.

S1-ICM281

S1-ICM282

152

DESCRIPTION

MODEL SELECTION OF 80+ AND 90+ FURNACE OPERATION

INCLUDES ADAPTER HARNESS

VOLTAGES

TIME DELAYS

LINE RANGE: 98–132 VAC @ 60 HZ IGNITER: 5A @ 120 VAC COOL BLOWER: 10A, 2HP, 240 VAC HEAT: 5A 1/2HP, 240 VAC INDUCER MOTOR: 4A, FLA-8.0 LRA @ 120 VAC GAS VALVE: 1.5A @ 30 VAC

HEAT BLOWER ON: 40 SEC. HEAT BLOWER OFF: 90, 135, 180, 225 SEC. FAN (LOW) ON/OFF: 1 SEC. COOL ON: 5 SEC. COOL OFF: 90 SEC. HEAT BLOWER ON: 60 SEC. HEAT BLOWER OFF: 90, 120, 150, 180 SEC. FAN (HEAT) ON/OFF: 1 SEC. COOL ON: 2 SEC. COOL OFF: 90 SEC. JUMPER JW2 UNCUT; 5 SEC., JUMPER JW2 CUT

STOCKED NON STOCKED

MLP

$208.04

162.32

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TIME DELAYS

Fixed Delay Time Delays

S1-ICM100 S1-ICM100F S1-ICM101 S1-ICM101F

• Voltage Drop: 2.5 VAC max @ 1.5 amps on make timers; 4.5 VAC max @ 1.5 amp, 3 amps typical on break timers • Bypass resistor: <1 K @ 24 VAC Mechanical: Mounting: surface mount using (1) #8 or #10 screw Environmental: • Operating temperature: –40° to +75°C, –40° to +167°F • Transient protection: meets IEEE 587 standards for categories A & B without false output or degradation. (6kv 0.5 µs x 100 Khz ring wave, 6kv 1.2 x 50 µs impulse wave)

Features: • Works with anticipator type thermostats • Higher 1.5 amp power rating • Simple, 2 wire hookup • Compact 2” x 2” package Input: • Control Voltage: 18–30 VAC • Frequency: 50/60 Hz • Power Consumption: 2 watts max. during timing Output: • Ratings: max. 1.5 amps, min. 40 µa, inrush 15 amps SOURCE 1 PART NO. * S1-ICM100 S1-ICM100F S1-ICM101 S1-ICM101F

MFG. NUMBER

TIME DELAY

ICM100 ICM100F ICM101 ICM101F

3 MIN. 3 MIN. 5 MIN. 5 MIN.

DELAY ON MAKE ON MAKE

MLP $24.82 11.59 24.82 11.59

* F suffix denotes 6” wire leads

Adjustable Delay Time Delays

0

S1-ICM102 S1-ICM102F

0

S1-ICM103

Features: • Knob-adjustable time delays • Higher 1.5 amp power rating • Simple, 2 wire hookup • Compact 2” x 2” package • Works with anticipator type thermostats • Spin proof knob • 6” wire leads Input: • Control Voltage: 18–240 VAC SOURCE 1 PART NO. * S1-ICM102 S1-ICM102F S1-ICM103 S1-ICM104 S1-ICM105

0

S1-ICM104

S1-ICM105

• Frequency: 50/60 Hz • Power Consumption: 2 watts max. during timing Output: • Ratings: max. 1.5 amps, min. 40 µa, inrush 15 amps • Voltage Drop: 2.5 v max @ 1.5 amps on make timers; 4.5 v max @ 1.5 amp, 3 amps typical on break timers • Bypass resistor: <1 K @ 24 VAC MFG. NUMBER

TIME DELAY

ICM102 ICM102F ICM103 ICM104 ICM105

0.03–10 MIN. (1.8–600 SEC.) 0.03–10 MIN. (1.8–600 SEC.) 1–1023 SEC. 10–1000 SEC. 1.8–600 SEC.

Mechanical: Mounting: surface mount using (1) #8 or #10 screw Environmental: • Operating temperature: –40° to +75°C, –40° to +167°F • Transient protection: meets IEEE 587 standards for categories A & B without false output or degradation. (6 Kv 0.5 µs x 100 Khz ring wave, 6 Kv 1.2 x 50 µs impulse wave)

DELAY ON MAKE

MLP $11.59 11.59 35.54 59.82 24.82

* F suffix denotes 6” wire leads

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

153


hemrichelectric.com

info@hemrichelectric.com

TIME DELAYS

Bypass Timers Series 175 Low pressure or oil switch bypass during startup, ideal for low ambient startups, integral component for “winter start” kits... The Series 175 may be S1-ICM175 used as an integral component in “winter start kits”, ideal for bypassing switches and for low ambient startups. • 18-240 VAC operation • Extends on-time switch closures • Knob-adjustable delays: .01-1,000 sec. • Precise digital timing circuitry • One model replaces several in field • Compact 2” x 2” package • Epoxy-encapsulated circuitry

recognized: E53944 certified: LR 30320 • Used to bypass a control or device during startup. Typically used to bypass a low pressure switch during compressor heat pump startup or to bypass an oil pressure switch upon startup. Ideal in low ambient conditions. Integral component for “winter start’ kits. Helps to eliminate nuisance lockouts. With power applied to the input, the load is energized immediately and remains energized for the length of the time delay. At the end of the time delay, the condition of the load is determined by the state of the bypassed switch. Specifications Input • Control voltage: 18-240 VAC • Frequency: 50/60 Hz • Power consumption: 3 watts max. SOURCE 1 PART NO. S1-ICM175

154

Output • Ratings: max. 1 amp, min. 40 µa, inrush 10 amps • Voltage drop: 2.5 V max. @ 1 amp • Leakage current: 5 µa max. @ 240 VAC Time Delay • Type: knob adjustable • Range: 10-1,000 sec. • Tolerance: 20% of selected time Mechanical Mounting: surface mount using (1) #8 or #10 screw Environmental • Operating temperature: -40° to +75°C, -40° to +167°F • Transient protection: meets IEEE 587 standards for categories A & B without false output or degradation. (6Kv 0.5 µs x 100 KHz ring wave)(6Kv 1.2 x 50 µs impulse wave)

ICM PART NO./ PRODUCT CODE

MLP

ICM175B/GPS00C2X1000P

$30.88

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

TIME DELAYS

Delay On Break Timers

S1-AMS

S1-ICM200, S1-ICM200F S1-ICM201, S1-ICM201F

S1-AMS

S1-ICM204, S1-ICM205, S1-ICM206

S1-ICM211

S1-ICM210, S1-ICM212

S1-ICM207, S1-ICM208, S1-ICM209

ICM’s Delay on Break (DOB) Timers are low cost, direct OEM replacements that offer reliable, lasting protection for your HVACR equipment. Provide anti-short cycle protection for SOURCE 1 PART NO.

S1-ICM203, S1-ICM203F

your air conditioning, refrigeration and heat pump equipment. Each unit features rugged, compact packaging and high power relays. UL listed. Choose from our extensive product

selection to best meet the needs of your application.

TIME DELAY

FEATURES: RELIABLE ANTI-SHORT CYCLE PROTECTION LOCKOUT DELAY IS IDEAL TO HELP PREVENT THE RAPID SHORT CYCLING OF COMPRESSORS IN HVACR EQUIPMENT FIXED TIME DELAYS FROM 0.1–600 SECONDS BUILT-IN TRANSIENT PROTECTION 24–240 VAC FACTORY FIXED

REPLACES

0.1–600 SEC.

TRANE: X13270061-01

S1-ICM200 S1-ICM200F S1-ICM201

3 MIN.

COMPRESSOR LOCKOUT/ANTI-SHORT CYCLE TIMER HELPS TO PROTECT COMPRESSORS FROM DAMAGE CAUSED BY RAPID SHORT CYCLING SIMPLE, 2-WIRE HOOKUP FIXED TIMING 18–30 VAC

5 MIN.

S1-ICM201F

S1-ICM203

COMPRESSOR LOCKOUT/ANTI-SHORT CYCLE TIMER HELPS TO PROTECT COMPRESSORS FROM DAMAGE CAUSED BY RAPID SHORT CYCLING SIMPLE, 2-WIRE HOOKUP ADJUSTABLE TIMING UNIVERSAL VOLTAGE

0.03–10 MIN. (1.8–600 SEC.) KNOB-ADJUSTABLE

S1-ICM203F

S1-ICM204

S1-ICM205

3 MIN. COMPRESSOR LOCKOUT/ANTI-SHORT CYCLE TIMER BROWNOUT PROTECTION UL 873 RECOGNITION AS COMPRESSOR CONTROLLER HELPS PREVENT SCROLL COMPRESSOR REVERSAL 18–30 VAC

3–10 MIN. ADJUSTABLE

S1-ICM206

S1-ICM207

S1-ICM208

5 MIN.

3 MIN. COMPRESSOR LOCKOUT/ANTI-SHORT CYCLE TIMER HELPS PREVENT SCROLL COMPRESSOR REVERSAL WORKS WITH ANTICIPATOR-TYPE THERMOSTATS FIXED OR ADJUSTABLE TIMING UNIVERSAL VOLTAGE OPERATION

5 MIN. 0.03–10 MIN. ADJUSTABLE

S1-ICM209

A-1: EAC-501-180-W DIVERSIFIED: AC-100-3 SUPCO: TD733 A-1: EAC-500 SUPCO: TD733W A-1: EAC-500, EAC-501-300-W DIVERSIFIED: ACS-500-5 SUPCO: TD735 A-1: EAC-500, EAC-501-300-W DIVERSIFIED: AC-505-5 SUPCO: TD735W A-1: EAC-501-ADJ DIVERSIFIED: AC-503 MARS: 32092, 32392 ROBERTSHAW: 3310-072 SUPCO: TD-73 WAGNER/DIVERSITECH: ADB-1 SUPCO: TD73W WAGNER/DIVERSITECH: ADB-2 A-1: EAC-426-180 DIVERSIFIED: AC-100-3 MARS: 32381, 32565 ROBERTSHAW: 3310-183 SUPCO: TL243 A-1: EAC-426-300 DIVERSIFIED: AC-100-5 MARS: 32382 ROBERTSHAW: 3310-305 SUPCO: TL245 A-1: EAC-426-ADJ A-1: EAC-426-180 DIVERSIFIED: AC-100-3 MARS: 32381 ROBERTSHAW: 3310-183 SUPCO: TL243 A-1: EAC-426-300 DIVERSIFIED: AC-100-5 MARS: 32382 ROBERTSHAW: 3310-305 SUPCO: TL245 A-1: EAC-426-ADJ

MLP

$28.39

24.82 16.07 24.82 16.07

14.50

16.72

23.21

20.34

28.39

24.11

24.11

28.39

(Table 1 of 2)

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

155


hemrichelectric.com

info@hemrichelectric.com

SOURCE 1 PART NO.

S1-ICM210

S1-ICM211

S1-ICM212

TIME DELAY

FEATURES: UL 873 RECOGNITION AS COMPRESSOR CONTROLLER COMPRESSOR LOCKOUT ANTI-SHORT CYCLE TIMER PLUS RANDOM START FUNCTION DUAL FUNCTION DELAY ON MAKE/BREAK RANDOM START DELAY IS IDEAL FOR STAGGER-STARTING MULTIPLE UNITS FIXED TIMING 18–30 VAC UL 873 RECOGNITION AS COMPRESSOR CONTROLLER COMPRESSOR LOCKOUT/ANTI-SHORT CYCLE TIMER LOW COST, OPEN BOARD PACKAGE CONFORMALLY COATED FOR ADDED PROTECTION FIXED TIMING 18–30 VAC UL 873 RECOGNITION AS COMPRESSOR CONTROLLER COMPRESSOR LOCKOUT ANTI-SHORT CYCLE TIMER PLUS RANDOM START FUNCTION DUAL FUNCTION DELAY ON MAKE/BREAK RANDOM START DELAY IS IDEAL FOR STAGGER-STARTING MULTIPLE UNITS FIXED TIMING 18–30 VAC PLASTIC STANDOFFS

REPLACES

MLP

A-1: EAC 650

5 MIN.

$22.32

N/A

18.75

A-1: EAC 650

22.32

(Table 2 of 2)

Random Start Timers Ideal for use in compressor staging and to stagger-start multiple rooftop units. Helps to reduce power surges. Features: • Delay on make/delay on break • UL 873 recognition as compressor controller • Compressor lockout/anti-short cycle timer • Integral random start capability

0

S1-ICM150 SOURCE 1 PART NO. S1-ICM150 S1-ICM151

S1-ICM151

ADDITIONAL FEATURES

TIME DELAY

SPST, N.O.

6–600 SEC. VOLTAGE DROP 1.5V @ 1A

SAFETY SWITCH LOCKOUT; REMOTE THERMOSTAT RESET

• Knob-adjustable time delay Specifications: Voltage: 18–30 VAC Current: 1A maximum; 40mA minimum Inrush: 10A

DIMENSIONS (INCHES)

REPLACES

MLP

2X2

DIVERSIFIED: ASC-200

$33.93

2X3

BARD: 8201-088 CARRIER: HN67KZ002 YORK: 031-01204-000

58.93

–0.1 THRU 600 SEC.

Duty Cycle Timers Features: • Duty cycle timer ideal for defrost applications • Suitable for process equipment or applications requiring intermittent delays • Switch-settable time delays • Epoxy-encapsulated for greater reliability SOURCE 1 PART NO. S1-ICM305 S1-ICM306

156

TIME DELAY SWITCH-SETTABLE FROM 1–1023 MIN. IN 1-MIN. INTERVALS SWITCH-SETTABLE FROM 1–1023 SEC. IN 1-SEC. INTERVALS

STOCKED NON STOCKED

• On time starts at power up. Specifications: Voltage: 18–240 VAC 1A Inrush: 10A Dimensions: 2” x 3” MLP $63.39 63.39

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Freeze Protection Modules Low-cost, fixed, single setpoint temperature controls that provide freeze protection. Features: • Epoxy encapsulated for moisture protection • Temperature sensor included Specifications: Input Voltage: 18–30 VAC SOURCE 1 PART NO. S1-ICM308 S1-ICM309 S1-ICM310

Input Frequency: 50–60 Hz Output: Solid state (triac), 1.5A @ 30 VAC Dimensions: 2” x 2” x 1-1/4”

TEMPERATURE CUT-OUT (OFF)

TEMPERATURE CUT-IN (ON)

MLP

43°F 28°F 44°F

45°F 55°F 48°F

$19.46 19.46 19.46

TIME DELAYS

Post-Purge Fan Delay Timers Series 251, 252, 253, 254 & 255

S1-ICM253

S1-ICM251

Adjustable OFF delay timer, controls the circulating fan in heat pump, and AC forced air systems... The Series 253 provides reliable OFF delay timing in a rugged package. The OFF delay is knob-adjustable from 12-390 sec. • Knob-adjustable OFF delay: 12-390 sec. • OFF delay purges ducts of residual air at the end of the heating/cooling cycle • Helps increase overall system efficiency • Epoxy-encapsulated circuitry • Solid state reliability • Low cost • recognized: E118867 certified: LR 30320 • Controls the circulating fan in heat pump, air conditioning & forced air systems. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby SOURCE 1 PART NO.

S1-ICM254

purging ducts of residual air and increasing system efficiency. • Power must be applied before and during the time delay period. When the initiate contact closes, the load energizes and remains energized as long as the initiate contact is closed. The time delay begins when the initiate contact opens. At the end of the time delay period, the load is turned off. If the initiate contact recloses during the time delay period the load remains energized and the time delay is reset to zero. Removal of input power during the delay turns off the load and resets the time delay to zero. A one second interrogation delay is provided to avoid nuisance trips due to thermostat bounce or tampering. Specifications Input • Control voltage: 18-30 VAC

ICM PART NO./ PRODUCT CODE

S1-ICM251

ICM251

S1-ICM253

ICM253

S1-ICM254

ICM254

S1-ICM255

ICM255

S1-ICM255

• Frequency: 50/60 Hz • Power consumption: 2 watts max. Output • Ratings: max. 1 amp, min. 40 µa, inrush 10 amps • Voltage drop: 1.25 V max. @ 1 amp Time Delay • Type: knob-adjustable only • Range: OFF delay: 12-390 sec. Mechanical Mounting: surface mount using (1) #8 or #10 screw Environmental • Operating temperature: -40° to +75°C, -40° to +167°F • Transient protection: meets IEEE 587 standards for categories A & B without false output or degradation (6Kv 0.5 µs x 100 KHz ring wave)(6Kv 1.2 x 50 µs impulse wave)

REPLACES MARS: 32377, 32378, 32379 FIELD CONTROLS: 46144700 GEMLINE: 1C216 MARS: 32393 HONEYWELL: S876A1016 WATSCO: PSTD-000-005W, PSTD-000-060W A-1: 5893 BARD: 8201-056 MARS: 32393 RHEEM: 42-22515-01, 42,22515-02, 42-22515-03 SNYDER GENERAL/ICP: 1395336

MLP $23.52 30.88 19.43

26.83

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

157


hemrichelectric.com

info@hemrichelectric.com

DEFROST CONTROLS

Timers & Controls 0

S1-ICM300

S1-ICM316

S1-ICM322 SOURCE 1 PART NO.

0

S1-ICM301

S1-ICM317

0

SI-ICM302

S1-ICM304

S1-ICM318

S1-ICM319

Specifications: Input Frequency: 50/60 Hz Power Consumption: 1 watt maximum Output Type: Relay Defrost Time Delay: Fixed 10 minutes ±5%

APPLICATION

INPUT VOLTAGE

S1-ICM300 S1-ICM301

HEAT PUMP DEFROST TIMER

18–30 VAC 18–30 VAC

S1-ICM302

DEFROST TIMER WITH HIGH POWER FAN RELAY OUTPUT

18–30 VAC

S1-ICM304

18–30 VAC HEAT PUMP DEFROST TIMER

S1-ICM307

18–30 VAC

S1-ICM315

SOLID STATE DEFROST CONTROL

24, 120 OR 240 VAC

S1-ICM316

SOLID STATE DEFROST TIMER

18–30 VAC

S1-ICM317

18–30 VAC

S1-ICM318

18–30 VAC

S1-ICM319

HEAT PUMP DEFROST TIMER

S1-ICM321

18–30 VAC

18–30 VAC

S1-ICM320

SOLID STATE DEFROST CONTROL

18–30 VAC

S1-ICM322

HEAT PUMP DEFROST TIMER

18–30 VAC

S1-ICM323

HEAT PUMP DEFROST CONTROL

18–30 VAC

158

0

0

S1-ICM307

S1-ICM315

S1-ICM320 S1-ICM321

Power on Reset Time: 500 milliseconds Test Time: Short across test terminals reduces test time 256x S1-ICM323

OUTPUT

INTERVAL TIME BETWEEN DEFROSTS (PIN-SELECTABLE)

MLP

RELAY, SPST, N.O., 1A RELAY, SPST, N.O, 1A

30/60/90 MIN 30/60/90 MIN

$ 38.85 40.89

RATING: 1 AMP @ 30VAC

30/60/90 MIN

105.18

30/60/90 MIN

96.25

W: RELAY, SPST, N.O., 10A @ 24 VAC RVS,CC: TRIAC, SPST, N.O., 10A @ 240 VAC FAN: RELAY, SPST, N.O., 10A @ 240 VAC COMPRESSOR CONTACTS: TRIAC, 1A DEFROST RELAY: TRIAC, 1A N.O.: 20A N.C.: 10A @ 240 VAC O, X2: DPST, N.O., 1A @ 30 VAC ODF: SPDT, N.C., 1A @ 230 VAC EDR: DPDT, N.C., 1A @ 30 VAC RELAY, SPST, N.O, 1A 1/2 HP 240 VAC OUTDOOR FAN RELAY 24 VAC 1A STRIP HEAT REVERSING VALVE O, X2: DPST, N.O., 1A @ 30 VAC DF1, DF2: SPST, N.O., 1/2 HP @ 240 VAC 1/2 HP 240 VAC OUTDOOR FAN RELAY 24 VAC 1A STRIP HEAT REVERSING VALVE O, W2: DPST, N.O., 1A @ 30 VAC RESISTIVE T1, T2: SPST, N.O., 10A @ 24 VAC DF1, DF2: SPST, N.O., 1/2 HP @ 240 VAC O, W2: DPST, N.O., 1A @30 VAC RESISTIVE T1, T2: SPST, N.O., 1A @ 30 VAC OF1, OF2: SPST, N.O., 1/2HP @ 240 VAC O, W2: DPST, N.O., 2A @ 24 VAC DF1, DF2: SPST, N.O., 10A @ 240 VAC O, W2: DPST, N.O., 1A @ 30 VAC T1, T2: SPST, N.O., 1A @ 30 VAC OF1, OF2: SPST, N.O., 1/2 HP @ 240 VAC 24 VAC, 1A STRIP HEAT REVERSING VALVES

STOCKED NON STOCKED

30/60/90 MIN

43.75

30/60/90 MIN

168.73

50/70/90 MIN

139.56

50/70/90 MIN

50.89

30/60/90 MIN

67.68

30/60/90 MIN

78.39

30/50/90 MIN

106.66

30/50/90 MIN

111.43

30/50/90 MIN

89.11

30/60/90 MIN

96.25

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

HEAD PRESSURE CONTROLS

Head Pressure Controls with Heat Pump Bypass For single or multiple refrigerant circuits, helps to prevent evaporator freezeups, low pressure cut-outs and liquidslugged compressors during low S1-52531425000 ambient conditions... The ICM325H regulates head pressure at low ambients by varying the airflow through the condenser. It helps to ensure sufficient pressure differential across the expansion valve and prevent costly downtime and/or wasteful spoilage of perishable goods. The ICM325H is ideally suited for refrigeration applications such as supermarkets, computer rooms, frozen food storage and other temperature and humidity-sensitive environments. Features • Prevents nuisance trips, protects perishable goods...by preventing evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors.

• 120-480 VAC Operation...reduces inventory. • Hard Start...adjustable from 1–5 seconds. Provides full torque to the motor during startup to help ensure proper fan rotation and lubrication of bearings. • High Temperature Bypass...applies full voltage to the condenser fan under normal conditions. • Low Speed Cutoff...field-adjustable. User may set the minimum RPM level at which the condenser fan should operate. • Rugged, Compact, Epoxy-encapsulated Package. • recognized: E118867 certified: LR 30320. Specifications Input • Control Voltage: 18–30 VAC • Line Voltage: 120–480 VAC • Frequency: 50/60 Hz • Power consumption: 4 VA @ 24 VAC • Isolation (input to output): 2500V minimum

SOURCE 1 PART NO. S1-ICM325H S1-ICM330

Output • Type: solid state • Form: triac • max: 10 amps • min: 100 mA • Frequency: 50/60 Hz • Voltage drop: 3.0 Volts maximum • Leakage current: 5 µa maximum Protection • Dielectric breakdown: 2,500 volts minimum • Insulation resistance: 100 M Environmental • Operating temperature: -40° to +65°C, -40° to +149°F • Storage temperature: -40° to +85°C, -40° to +185°F • Humidity: 95% relative Physical • Mounting: surface mount using (4) #8 screws • Terminations: .25” male quick-connect terminals • Weight: 11 ounces

REFRIGERANT CIRCUITS

MAXIMUM OUTPUT

MLP

UP TO 3 1

10A 4A

$241.07 306.96

Mode of Operation Upon initial application of the 24 VAC control voltage, the output voltage shall be in the Hard Start mode for a specified period of time. This time is field adjustable from .1 – 5 seconds. Upon completion of the Hard Start period, the output voltage control reverts to the thermistor. Speed control will not occur until the line temperature falls below 103°F (based upon use of the S1-ICM379 probe). Full voltage will be applied to the motor such that there is no loss in condensing efficiency. As the temperature being sensed decreases, the output voltage decreases. The output voltage may decrease to the determined Low Temperature Cutoff. Upon reaching the Low Temperature Cutoff setting, the output voltage shall go to zero volts. The Low Temperature Cutoff setting is field adjustable. System restart with a Hard Start period shall occur when the temperature exceeds the Low Temperature Cutoff temperature by a pre-determined amount which is the system Hysteresis (Deadband). The system Hysteresis is factory fixed. Removal of the 24 VAC control voltage shall de-energize the output immediately. Re-application of the 24 VAC shall energize the output at a maximum voltage for the Hard Start duration, if the temperature at the thermistor is above the low temperature cutoff.

Head Pressure Controls

S1-ICM326H

S1-ICM327H SOURCE 1 PART NO.

Features: • Built-in transformer eliminates cost, reduces installation time and simplifies wiring • Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions • Hard start, low temperature cutoff, high temperature bypass INPUT CONTROL

S1-ICM326H

120 OR 208/240 VAC

S1-ICM327H

480 VAC

• Ideal for line voltage air conditioning and refrigeration Specifications: Input Frequency: 50–60 Hz Output Maximum: 10A Output Minimum: 100 mA Modulation: 70°–100°F Dimensions: 4.5” x 3” x 2”

REPLACES

MLP

ACT: FM4000 HOFFMAN: 800, 800A, 800AA, 814-50, 816-10 JOHNSON CONTROLS: P66 RANCO: E31

$275.89 292.68

Probe for Head Pressure Controls with Optional Heat Pump Bypass Feature SOURCE 1 PART NO. S1-ICM379

FOR USE WITH

LENGTH

TEMPERATURE

MLP

S1-ICM325H S1-ICM326H S1-ICM327H

6’ 7”

70°–100°F 21°–38°C

$51.25

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

159


hemrichelectric.com

info@hemrichelectric.com

Condensation Controls

S1-ACH55 S1-ICM342

S1-ICM340

ICM’s condensate control systems protect cooling and refrigeration equipment by detecting and preventing overflows in the evaporator SOURCE 1 PART NO.

S1-ICM340

S1-ICM342

S1-ICM345

condensation pan due to slow and/or blocked drains or pump failure.

ADDITIONAL FEATURES 2 SENSORS MAX. OPERATING/STORAGE RH 95% NON-CONDENSING STORAGE TEMPERATURE: -40° TO 85°C REPLACES WATER GUARD: 401475 ALARM OUTPUT DURING LOCKOUT CONFORMAL COATING FOR MOISTURE PROTECTION AUDIBLE/VISIBLE CONDENSATION ALARM ASC COMPRESSOR PROTECTION WORKS WITH ANY EXISTING THERMOSTAT OR CONDENSATION CONTROL SOURCE 1 PART NO. S1-ACH55

S1-ICM345

Specifications: Input: 18–30 VAC, 50–60 Hz

OUTPUT

DELAY

DIMENSIONS (INCHES)

MLP

24 VAC TO THERMOSTAT/ COOLING CONTROL 24 VAC TO OPTIONAL OVERFLOW LED 2 AMPS

1–3 MIN.

$49.11

TYPE: RELAY N.O.: 10A @ 120 VAC N.C.: 10 A @ 120 VAC

ON MAKE CUSTOM AVAILABLE, FIXED OR ADJUSTABLE

2.75 X 3.25

27.32

TYPE: RELAY N.O.: 1A @ 30 VAC

ANTI-SHORT CYCLE: 5 MIN. FIXED

4.5 X 2.75 X 0.875

41.61

DESCRIPTION

MLP

OPTIONAL OVERFLOW ALARM LED KIT FOR USE WITH S1-ICM340 OR S1-ICM342 CABLE LENGTH: 6 FT.

$23.75

Lockout Protection

S1-ICM221

S1-ICM220

The S1-ICM221 is a low-cost compressor protection module that monitors safety switch inputs and provides anti-short cycle protection. S1-ICM220 and S1-ICM222 are low-cost lockSOURCE 1 PART NO. S1-ICM220 S1-ICM221 S1-ICM222

160

out protection modules that monitor various switch inputs to help protect the compressor. Specifications:

S1-ICM222

Voltage: 18–30 VAC Frequency: 50–60 Hz

DESCRIPTION COMPRESSOR CONTROLLER, LOCKOUT RELAY IDEAL FOR USE WITH SAFETY/INTERLOCK SWITCHES 2 WATTS MAX. POWER CONSUMPTION @ LOCKOUT RELAY: 1 FORM C, CONTACTS: 2A @ 30 VAC RESISTIVE COMPRESSOR PROTECTION MODULE WITH 1-SECOND INTERROGATION SAFETY SWITCH MONITORING 3 OR 6 SEC. DELAY ON MAKE, SELECTABLE 10 SEC. OR 5 MIN. ANTI-SHORT CYCLE TIME LOCKOUT PROTECTION MODULE WITH PRESSURE/FLOW SWITCH MONITORING FAULT TYPE: RELAY (SPDT) N.O., FAULT RATING: 1A @ 30 VAC 5 MIN. FIXED ANTI-SHORT CYCLE TIME ±20% (5 SEC. TEST MODE)

STOCKED NON STOCKED

DIMENSIONS (INCHES)

MLP

2X2

$31.96

3.25 X 3 X 1

48.04

3.5 X 3.25 X 1

48.04

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

LINE MONITORS

3-Phase Monitor ICM402 If all three phases are relatively equal and in proper sequence, the normally open contacts (Y/Y-OUT) will close when 115/230 volts is applied between C and 115/230 VAC terminals. If the phases are out of sequence, or if one is missing, the contacts will never close. Features: • Low cost, single side 3-phase protection • 30 amp output • Bright LED indicators for fault and load energized • Easy to install; no adjustments

S1-ICM402

The ICM402 is a low cost 3-phase line monitor, with a 30 amp output that protects against phase loss, phase reversal and phase unbalance. Ideally suited to protect scroll and screw compressors from reverse rotation.

• • • • •

Wide operating range: 190–600 VAC Less than 1 second phase loss response Automatic reset from a fault condition Compact packaging: fits almost anywhere Rugged, epoxy-encapsulation for extreme conditions • Works well with the ICM450 for load side monitoring of part winding start motors and multiple compressor systems Dimensions: 3.0” x 3.25” x 1.25”

INPUT SOURCE 1 PART NO. S1-ICM402

LINE VOLTAGE

DESCRIPTION 3-PHASE LINE MONITOR

190–600 VAC

FREQUENCY 50/60 HZ

CONTROL VOLTAGE 115 OR 230/240 VAC

OUTPUT

MLP

SPST N.O. 30A

$74.04

3-Phase Voltage Monitor-Programmable ICM450

S1-ICM450 or S1-ICM450-S

Stop Motor Burnouts! 3-Phase line voltage monitor with 25-fault memory, high-temperature LCD display, easy setup & clear diagnostic display of system faults, 190-630 VAC operation... The ICM450 was specifically designed to protect motors and other 3-phase loads from premature failure and damage due to common voltage faults such as voltage unbalance, over/ under voltage, phase loss, reversal, incorrect sequencing and rapid short cycling. Features • Reliable, high temperature LCD display ... simplifies system setup and diagnostics. Indicates condition of incoming line voltage, fault conditions, system setpoints and other user adjustments. Temp.: -20° to +75°C (-4° to +167°F) • Simultaneous voltage display...an ICM exclusive! View all 3 phases, no need to scroll through readouts. • Fully adjustable variables...user may easily set and adjust variables when in SETUP mode: • Line voltage: 190-600 VAC • Voltage unbalance: 2-20% • Delay on break period: 0-10 min. SOURCE 1 PART NO. S1-ICM450

• Fault interrogation: 0-15 sec. • Over/under voltage: 2-25% • Reset modes: AUTO or 0-10 Retries • Control modes: ON or OFF Specifications Input • Line voltage: universal- 190-630 VAC • Frequency: 50/60 Hz Output • Type: relay, SPDT • Voltage range: Up to 240 VAC (Max: 10 amps) • Frequency: 50/60 Hz Control Operating Temperature • Operating temperature: -40° to +75°C, -40° to 167°F • Storage temperature: -40° to +85°C, -40° to 185°F LCD Operating Temperature Operating temperature: -20° to +75°C, -4° to 167°F Phase Unbalance Protection Voltage unbalance: 2-20% adjustable Over/under protection • Under voltage: 2-25% adjustable • Over voltage: 2-25% adjustable Phase Loss Protection Phase loss condition= <25% of nominal for any given phase. System will shut down and a fault will be recorded should this condition occur. Delay on Break Timer • Control voltage: 18-240 VAC

• Time delay: 0-10 min. adjustable Fault Interrogation Delay • Time delay: 0-15 sec. adjustable • Provides a delay between fault detection & system shut-down - eliminating nuisance trips/unnecessary shutdowns. Mechanical • Mounting: surface mount using (2) #8 screws • Termination: screw terminals • Weight: 12 ounces (341 grams) • Easy to install and configure...wiring diagram on unit, simple 7-step push-button setup, guide included. • 25-Fault memory and storage...clearly displayed in LCD • Ultra bright LED indicators...shows current mode: Setup LED Load energized LED Control voltage LED Fault LED Dimensions: 6.5” x 4.25” x 1.4” Exclusive ICM Features 1. View all 3 voltages at once. 2. Front and back side fault identification. 3. Independent over/under voltage % adjustment. 4. ICM450 wiring diagram printed right on cover. 5. High-temperature LCD: –20° to +75°C, -4° to 167°F. 6. Line voltage programmable - (no step-up transformer needed).

ICM PART NO./ PRODUCT CODE

REPLACES

MLP

ICM450

S1-52531424000

$292.12

Spanish-Language Model

S1-ICM450-S

ICM450S

A-1: EAC-800, EAC-8000, EAC-8002 COPELAND: 085-0160-00 DIVERSIFIED: AC-2020, AC-301, AC-302 MOTORSAVER: 455 SSAC: QLM, QLV TIMEMARK: 265 WAGNER/DIVERSITECH: DPT-3, WPC-800

$326.79

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

161


hemrichelectric.com

info@hemrichelectric.com

LINE MONITORS

3-Phase Voltage Monitor ICM400

S1-ICM400

Stop Motor Burnouts! High performance, low cost model, front and back side protection, 7 bright fault LEDs, integral short-cycle protection, easy setup, fully adjustable features, 190-630 VAC... The ICM400 was specifically designed to protect motors and other 3-phase loads from premature failure and damage due to common voltage faults such as voltage unbalance, over/ under voltage, phase loss, reversal, incorrect sequencing and rapid short cycling. 3-Position Reset Switch, 50/60 Hz • Choose from 3 easy-to-select reset modes: Full manual Full automatic Auto front/manual back • Frequency: 50/60 Hz Features: • Bright LED’s show modes and identify faults: Load energized LED

Control voltage LED Lockout LED Front fault LED Back fault LED High voltage LED Low voltage LED • Knob-adjustable variables...user may easily select and adjust setpoints on unit: • Voltage unbalance: 2–25% • Delay on break period: 1–5 min. • Fault interrogation: 1–15 sec. Specifications Input • Line voltage: universal- 190-630 VAC • Frequency: 50/60 Hz Contactor Load Side (Back) • Line voltage: universal- 190-630 VAC • Load side monitoring is optional. Output • Type: relay • Voltage range: 240 VAC (max: 10 amps) Control Operating Temperature • Operating temperature: -40° to +75°C, -40° to 167°F • Storage temperature: -40° to +85°C, -40° to 185°F Phase Unbalance Protection Voltage unbalance: 2-25% adjustable

Over/Under Voltage Protection • Under/over voltage: fixed at 12% • Hysteresis: 6% • Low cost, high performance...full line protection and fault identification without costly LCD readout • Integral delay on break timer...knob-adjustable from 1-5 min., helps prevent rapid system recycling • Easy to install and configure... wiring diagram on unit, installation and application guide included Phase Loss Protection Phase loss condition = <25% of nominal for any given phase. System will shut down and a fault will be recorded should this condition occur. Delay on Break Timer: Time delay: 1–5 min. adjustable Fault Interrogation Delay • Time delay: 1-15 sec. Adjustable • Provides a delay between fault detection and system shutdown, eliminating nuisance trips/ unnecessary shutdowns. Mechanical • Mounting: surface mount using (2) #8 screws • Terminations: screw terminals • Weight: 12 ounces (341 grams) • Dimensions: 6.5” x 4.25” x 1.4”

INPUT SOURCE 1 PART NO. S1-ICM400

ICM PART NO./ PRODUCT CODE ICM400

LINE VOLTAGE

DESCRIPTION 3-PHASE VOLTAGE MONITOR

FREQUENCY‘

190–600 VAC

50/60 HZ

CONTROL VOLTAGE 18–240 VAC/VDC

OUTPUT

MLP

SPDT FREQUENCY: 50/60 HZ

$258.93

3-Phase Loss & Reversal Protection Features: • Reliable 3-phase protection for single side • Monitors for phase reversal, phase loss, unbalance percentage as a function of input voltage • Bright LED indicators for On and Fault • Highly reliable passive electronics • Phase reversal detection on power up Specifications: High Voltage Cut-Out Setpoint: +12%

S1-ICM409 S1-ICM408

SOURCE 1 PART NO. S1-ICM408 S1-ICM409

162

Low Voltage Cut-Out Setpoint: –12% Power/Phase Loss Detection: Within 100 ms User Selectable Unbalance Voltage: 2%–8% Voltage: 190–480 VAC Frequency: 50–60 Hz Adjustable Delay on Break: 1–5 min. Relay Output: N.O./N.C. contacts: 10A resistive @ 250 VAC

MOUNT

DELAY ON MAKE

MLP

8-PIN PLUG-IN DIN RAIL

1–5 MIN. HEAVY-DUTY SPDT

$118.75 144.46

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

LINE MONITORS

Single Phase Line Monitors Series 491 Undervoltage Protection • Voltage dropout: -12.5% • Voltage pickup: -7.5% Overvoltage Protection • Voltage dropout: +12.5% • Voltage pickup: +7.5% Mechanical • Mounting: surface mount using (4) #8 screws • Terminations: .25” male quick-connect terminals Response Times • Line dropout: .05 sec. (typical) • Control voltage dropout: .07 sec. (typical) • Line voltage sag (20%): .5 sec (typical) • Turn-on: 5 sec. (typical) Lockout Delay Timer Time delay: adj. 6-600 sec. (+/- 20%) Environmental • Operating temperature: -40° to +75°C, -40° to +176°F • Transient protection: meets IEEE 587 standards for categories A & B without false output or degradation (6Kv 0.5 µs x 100 KHz ring wave)(6Kv 1.2 x 50 ms impulse wave) Dimensions: 3.25” x 3” x 1.25”

Mode of Operation Upon application of power to the monitor, and provided all voltages are acceptable, the LED indicator light will glow, indicating that the output contacts have transferred. Should a voltage unbalance or high/low voltage condition exist for longer than the 5 sec. interrogation delay, the relay and LED shall be deenergized. Re-energization is automatic upon correction of the fault condition and after the anti-short cycle time delay period is complete. Should a fault condition exist upon application of power, the output relay will not energize. Adjustment: Select the proper operating line voltage. Apply power. If the relay fails to energize, check wiring. Adjust lockout time delay to desired setting. Each unit is shipped with a detailed Installation guide. Specifications Input • Line voltage: 95-270 VAC • Control voltage: 18-240 VAC/VDC • Line frequency: 50 or 60 Hz Output • Type: relay energized upon acceptable line conditions • Form: single pole double throw (SPDT) • Ratings: n.o.-5 amps, n.c.-5 amps

High/low voltage protection for single phase systems, 95-270 VAC operation, adjustable anti-short cycle timer, ultra low cost... The Series 490 was specifically designed to guard equipment against damage caused by under/over voltage and rapid system recycling. Low cost single phase equipment protection Protects against: -Over/under voltage conditions -Rapid system recycling LED Indication (continuous under normal conditions) Heavy Duty SPDT 8 amp Relay Output (isolated contacts) Interrogation Delay helps prevent nuisance tripping Integral, adjustable anti-short cycle protection

SOURCE 1 PART NO.

S1-ICM491

REPLACES A-1: EAC-401, 402, 403, 404 DIVERSIFIED: CV-100-RS, CV-200-RS15, CV-200-RS20 MARS: 32522, 32524, 32526 WAGNER/DIVERSITECH: DSP-1

MLP

$70.69

HEAD PRESSURE CONTROLS

3-Phase Head Pressure Controls Features: • Temperature, pressure, milliamp or DC voltage input • True sine wave output • Modulates voltage and frequency

SOURCE 1 PART NO. S1-ICM336 S1-ICM337

VAC

HP

208–240 460

1–3 1–5

REPLACES HOFFMAN: MOTORMASTER III

• LCD display for easy setup and monitoring • No need to change existing fan motor Specifications: Accessories: Optional pressure transducer available—S1-ICM380 (see below) Dimensions: 8.25” x 12.5” x 14” MLP $1910.71 1910.71

Accessories for ICM 3-Phase Head Pressure Controls SOURCE 1 PART NO.

S1-ICM380

S1-ICM381

DESCRIPTION

S1-ICM380

OPTIONAL PRESSURE TRANSDUCER *

S1-ICM381

TEMPERATURE PROBE

FOR USE WITH

LENGTH (IN.)

PSI

MLP

72

0–500

$294.46

79

N/A

S1-ICM336 S1-ICM337 S1-ICM330 S1-ICM336 S1-ICM337

50.89

* 1/4” SAE female flare with Schraeder deflator (6’ long)

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

163


hemrichelectric.com

info@hemrichelectric.com

MOTOR PROTECTION

3-Phase Motor Protection Protects Against: • Under voltage • Over temperature • Power interruptions • Rapid short cycling • Shorted temperature sensor • Open temperature sensor • Control duty, SPST relay layout SOURCE 1 PART NO.

S1-ICM441

164

REPLACES BRISTOL: 241680 COPELAND: 071-0376-01, 071-0376-02 071-0397-00, 071-0397-01 071-0424-00, 071-0424-01 071-9800-00, 071-9800-01 MARS: 37300, 37302, 37304, 37306, 37322 TEXAS INSTRUMENTS: 15AA 1600 B, 15AA 1600 C 15AA 1603 B, 15AA 1603C 31AA 1600 E, 31AA 1606E

STOCKED NON STOCKED

• Anti-short cycle time delay, 4 min. (nominal) • 1-second manual bypass Specifications: Voltage: 120 or 208/240 VAC Frequency: 50–60 Hz Output: Relay: SPDT N.O. 6A resistive Dimensions: 3.25” x 3” x 1.25”

MLP

$165.18

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

CAPACITORS

Direct Brand Run Capacitors

SOURCE 1 PART NO. S1-MMMINICAP20 S1-MMUNICAP200F

DESCRIPTION

MLP

MINI MOTOR-MATE RUN CAPACITOR MOTOR-MATE RUN CAPACITOR

$37.78 79.11

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

165


hemrichelectric.com

info@hemrichelectric.com

CAPACITORS

Single Run Capacitors Features: • Continuous duty for single phase AC motors • Non PCB liquid filled • 50 & 60 Hz operation • Tin plated 1/4 x .032 male terminals • Internally protected by pressure sensitive interrupter device • Aluminum case with terne plate steel cover

166

SOURCE 1 PART NO.

MFD

VOLTS

CAN STYLE

MLP

S1-CAP37020F S1-CAP37030F S1-CAP37040F S1-CAP37050F S1-CAP37050R S1-CAP37060F S1-CAP37075F S1-CAP37075R S1-CAP37100F S1-CAP37100R S1-CAP37125F S1-CAP37150F S1-CAP37175F S1-CAP37200F S1-CAP37250F S1-CAP37250R S1-CAP37300F S1-CAP37300R S1-CAP37350F S1-CAP37350R S1-CAP37400F S1-CAP37400R S1-CAP37450F S1-CAP37450R S1-CAP37500F S1-CAP37500R S1-CAP37550R S1-CAP37600F S1-CAP37600R S1-CAP37700F S1-CAP37800F S1-CAP37800R S1-CAP44030F S1-CAP44040F S1-CAP44050F S1-CAP44060F S1-CAP44075F S1-CAP44100F S1-CAP44125F S1-CAP44150F S1-CAP44150R S1-CAP44175F S1-CAP44200F S1-CAP44200R S1-CAP44250F S1-CAP44250R S1-CAP44300F S1-CAP44300R S1-CAP44350F S1-CAP44350R S1-CAP44400F S1-CAP44400R S1-CAP44450F S1-CAP44450R S1-CAP44500F S1-CAP44500R S1-CAP44550F S1-CAP44600F S1-CAP44600R S1-CAP44700R S1-CAP44800R

2.0 3.0 4.0 5.0 5.0 6.0 7.5 7.5 10.0 10.0 12.5 15.0 17.5 20.0 25.0 25.0 30.0 30.0 35.0 35.0 40.0 40.0 45.0 45.0 50.0 50.0 55.0 60.0 60.0 70.0 80.0 80.0 3.0 4.0 5.0 6.0 7.5 10.0 12.5 15.0 15.0 17.5 20.0 20.0 25.0 25.0 30.0 30.0 35.0 35.0 40.0 40.0 45.0 45.0 50.0 50.0 55.0 60.0 60.0 70.0 80.0

370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440

FLAT FLAT FLAT FLAT ROUND FLAT FLAT ROUND FLAT ROUND FLAT FLAT FLAT FLAT FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND ROUND FLAT ROUND FLAT FLAT ROUND FLAT FLAT FLAT FLAT FLAT FLAT FLAT FLAT ROUND FLAT FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT FLAT ROUND ROUND ROUND

$ 2.07 2.11 2.14 2.18 2.18 2.54 2.54 2.68 2.82 3.11 4.11 4.14 4.68 4.79 5.57 5.00 6.25 5.61 6.46 7.18 8.82 7.86 10.11 8.82 10.57 9.57 10.79 12.93 11.00 14.18 18.14 13.36 2.64 2.50 2.61 3.00 3.11 3.43 4.21 4.79 4.71 5.50 5.00 4.89 6.36 6.00 7.21 7.79 7.93 8.11 8.82 9.14 8.54 10.79 11.00 8.25 11.54 11.25 9.89 15.25 16.39

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

CAPACITORS

Dual Run Capacitors

MFD COMPR. FAN

SOURCE 1 PART NO.

NEW NEW

S1-CAP3704025DR S1-CAP3705015DF S1-CAP3705020DF S1-CAP3705020DR S1-CAP3705025DF S1-CAP3705025DR S1-CAP3705030DF S1-CAP3705030DR S1-CAP3705035DF S1-CAP3705035DR S1-CAP3705040DF S1-CAP3705040DR S1-CAP3705045DF S1-CAP3705045DR S1-CAP3705060DR S1-CAP3705080DR S1-CAP3707530DF S1-CAP3707535DF S1-CAP3707555DF S1-CAP3710015DF S1-CAP3710025DF S1-CAP3715020DF S1-CAP4405025DF S1-CAP4405025DR S1-CAP4405030DF S1-CAP4405030DR S1-CAP4405035DF S1-CAP4405035DR S1-CAP4405040DF S1-CAP4405040DR S1-CAP4405045DF S1-CAP4405045DR S1-CAP4405050DR S1-CAP4405055DR S1-CAP4405060DR S1-CAP4407530DR S1-CAP4407535DF S1-CAP4407535DR S1-CAP4407540DF S1-CAP3707545DF S1-CAP3707545DR S1-CAP4407560DR

25.0 15.0 20.0 20.0 25.0 25.0 30.0 30.0 35.0 35.0 40.0 40.0 45.0 45.0 60.0 80.0 30.0 35.0 55.0 15.0 25.0 20.0 25.0 25.0 30.0 30.0 35.0 35.0 40.0 40.0 45.0 45.0 50.0 55.0 60.0 30.0 35.0 35.0 40.0 45.0 45.0 60.0

4.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 10.0 10.0 15.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5

VOLTS

CAN STYLE

MLP

370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 370 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 440 370 370 440

ROUND FLAT FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND ROUND ROUND FLAT FLAT FLAT FLAT FLAT FLAT FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND FLAT ROUND ROUND ROUND ROUND ROUND FLAT ROUND FLAT FLAT ROUND ROUND

$ 6.89 6.79 6.75 6.96 7.18 6.96 7.82 7.54 9.21 8.64 10.86 10.39 12.18 10.64 13.18 17.89 8.57 9.82 16.39 7.75 9.14 8.57 9.43 6.61 7.96 7.00 8.71 8.00 9.29 8.79 11.39 10.68 11.36 11.79 12.32 8.29 10.79 11.54 9.46 13.93 13.68 13.11

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

167


hemrichelectric.com

info@hemrichelectric.com

CAPACITORS

Syntex Capacitor Boots

Features: • UL recognized component • Insulates capacitor terminals and prevents nuisance shocks • Black neoprene material

SOURCE 1 PART NO. S1-02804133000

SYNTEX RUBBER PART NO.

DIMENSIONS A

NO. TABS

REMARK

MLP

M-78

1.44

1

FOR STRAIGHT TERMINALS

$1.49

Start Capacitors Features: • Molded plastic case • Designed for 20 starts per hour duty cycle • 50/60 Hz operation • 1/4 x .032 male push on terminals • 15,000 OHM / 2 watt resistor

DIMENSIONS

SOURCE 1 PART NO. S1-02425071700 S1-02425075700 S1-02425076700 S1-02426023000 S1-1497-1761 S1-02425191700 S1-02408164700 S1-02425215700 S1-02425390700

168

MFD

VOLTS

CAN STYLE

D

H

MLP

145-175 161-193 189-227 297-356 176-216 88-108 108-130 189-227 270-324

250 250 250 250 320 330 330 330 330

ROUND ROUND ROUND ROUND ROUND ROUND ROUND ROUND ROUND

2.06 2.06 2.56 2.06 2.56 2.06 2.56 2.56 2.56

4.38 4.38 4.38 4.38 4.38 4.38 4.38 4.38 4.38

$17.23 17.27 24.79 31.13 34.25 18.42 16.61 25.56 28.57

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

Ventilation & Indoor Air Quality

Your Source1 Connection


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL AIR FILTRATION SYSTEMS VENTILATION & INDOOR AIR QUALITY

Affinity/Acclimate/Echelon Hybrid Media-Electronic Air Cleaners Features: • Whole home electronic air cleaner utilizes both the electrostatic attraction and filter media to provide a more consistent, higher level of performance. • Equivalent to MERV 16 • System matching appearance • When new: —97.8% effective at removing particles from 3 to 10 microns —95.7% effective at removing particles from 1 to 3 microns —92.0% effective at removing particles from 0.3 to 1 microns • Rated to 2000 cfm

• Support up to 400 lb. • Low airflow resistance: —0.10” w.g. @ 1000 cfm —0.29” w.g. @ 2000 cfm • Easy maintenance: —Replace filter media once per year —No washing of cells required, only wiping of ionizing wires once per year • Power usage does not exceed 60 watts • UL listed • Silent operation: no snapping from the electronic charge of particles • 5-year Warranty

SOURCE 1 PART NO.

MLP

S1-HEAC3000Y S1-HEAC3000L S1-HEAC3000C MEDIA S1-FM501

YORK LUXAIRE COLEMAN

$1267.86 1267.86 1267.86

HEAC3000 ELECT-HYBRID MEDIA

$70.71

Residential Electronic Air Cleaner Source 1 High Efficiency Electronic Air Cleaners remove airborne pollutants as small as 0.01 micron. That’s 1/2,540,000 of an inch! The air cleaners are environmentally friendly with their lifetime filter system that never needs replacing. Simply wash it clean and you save money. Features: • Carbon Filters that remove gaseous odors • Dual Indicator Lights show unit operation at a glance • Electronic Air Proving Switch cycles Air Cleaner On/Off with system fan • Most quiet operation versus other brands • User friendly and easy to maintain • Include Source 1, York, Coleman, and Luxaire labels

SOURCE 1 PART NO. S1-EAC14001625 S1-EAC14002020 S1-EAC20002025 S1-EAC2000GM

NOMINAL SIZE 16” X 25” 20” X 20” 20” X 25” GRILLE-MOUNTED

RATED AIRFLOW

INITIAL EFFICIENCY AT RATED AIR FLOW (AT 600 CFM) 0.3–1.0 1.0–3.0 3.0–10.0 MICRONS MICRONS MICRONS

1400 CFM

76.5% (99.7%)

94.0% (99.9%)

99.2% (100%)

2000 CFM

74.2% (99.87%) 71.4% (96.9%)

91.0% (99.0%) 90.0% (99.2%)

96.2% (100%) 97.5% (99.9%)

RATED VOLTAGE

COLLECTOR CELL MAINT INTERVAL

120V-1PH/60HZ

3 MONTHS

MLP $ 846.43 910.71 910.71 1589.29

Spare Parts for Residential Electronic Air Cleaners DESCRIPTION

S1-EAC14001625

S1-EAC14002020

S1-EAC20002025

MLP

ELECT POWER CIRCUIT BOARD IONIZING WIRE 20X12.5 COLLECTOR CELL PRE-FILTER SCREEN CHARCOAL PRE-FILTER ELECTRONIC AIR SENSOR

S1-4720 S1-4761 S1-4762 S1-4763 S1-4764 S1-4765

S1-4720 S1-4741 S1-4780 S1-4782 S1-4744 S1-4745

S1-4720 S1-4741 S1-4742 S1-4743 S1-4744 S1-4745

SEE 2009 PRICE BOOK

STOCKED NON STOCKED

HVAC SERVICE PARTS Your Source1 Connection

169


hemrichelectric.com

info@hemrichelectric.com

RESIDENTIAL AIR FILTRATION SYSTEMS

Affinity/Acclimate/Echelon High Efficiency Expandable Media Air Cleaners • • • •

Features: • The whole home media air cleaner permanently traps particles, including airborne contaminants, down to 1 micron (1 millionth of a meter) in size. Particles of less than 6 microns are invisible to the naked eye, and allergy-causing particles and mold spores range from 0.5 microns to 1 micron. • Helps minimize the risk of asthma and allergy attacks SOURCE 1 PART NO. NEW NEW NEW NEW NEW NEW

BRAND

S1-WHM10162505Y S1-WHM10162505L S1-WHM10162505C S1-WHM10202505Y S1-WHM10202505L S1-WHM10202505C

Up to 2 year filter media life Low static pressure drop MERV 10 efficiency rating 5-year limited warranty

DESCRIPTION

YORK LUXAIRE COLEMAN YORK LUXAIRE COLEMAN

MLP $367.86 367.86 367.86 384.82 384.82 384.82

16” X 25” WHOLE HOME EXPANDABLE MEDIA AIR CLEANER

20” X 25” WHOLE HOME EXPANDABLE MEDIA AIR CLEANER

Replacement Media for Affinity/Acclimate/Echelon High Efficiency Expandable Media Air Cleaners SOURCE 1 PART NO. NEW NEW

FOR MODEL NO.

S1-FM401 S1-FM201

MASTER CARTON QTY.

STD. PKG.

S1-WHM10162505 S1-WHM10202505

1

MLP $53.21 54.64

10

MERV10 High Efficiency Media Air Cleaners SOURCE 1 PART NO. S1-MAC10162505b S1-MAC10202505b S1-MAC10202005b

SIZE (INCHES)

DESCRIPTION MERV10 MEDIA AIR CLEANER (BRAND SELECTION REQUIRED BELOW) MERV10 MEDIA AIR CLEANER (BRAND SELECTION REQUIRED BELOW) MERV10 MEDIA AIR CLEANER (BRAND SELECTION REQUIRED BELOW)

STD. PALLET PKG. QTY.

MLP

16 X 25

1

20

$206.25

20 X 25

1

10

206.25

20 X 20 X 5

1

20

206.25

NOTE: Now includes branded door insert. Character replacing “b” in part number indicates brand: use Y for York, L for Luxaire, C for Coleman, and S for Source 1

Replacement Cartridges for MERV10 Media Air Cleaners SOURCE 1 PART NO. S1-FM10162505 S1-FM10202505 S1-FM10202005 S1-FM10162005HW S1-FM10162505HW S1-FM10202005HW S1-FM10202505HW

DESCRIPTION

SIZE (INCHES)

REPLACES

STD. PKG.

PALLET QTY.

MLP

MERV10 REPLACEMENT CARTRIDGE MEDIA MERV10 REPLACEMENT CARTRIDGE MEDIA MERV10 REPLACEMENT CARTRIDGE MEDIA

16 X 25 X 5 20 X 25 X 5 20 X 20 X 5

— — —

6 6 6

54 54 54

$31.11 35.00 32.23

5 5 5 5

80 60 80 60

31.50 34.18 35.64 37.61

REPLACEMENT MEDIA FOR HONEYWELL AIR CLEANERS MERV10 CARTRIDGE MEDIA 16 X 20 HONEYWELL FC100A1003 MERV10 CARTRIDGE MEDIA 16 X 25 HONEYWELL FC100A1029 MERV10 CARTRIDGE MEDIA 20 X 20 HONEYWELL FC100A1011 MERV10 CARTRIDGE MEDIA 20 X 25 HONEYWELL FC100A1037

Replacement Branded Door Inserts for Source 1 MERV 10 Media Air Cleaners SOURCE 1 PART NO. S1-ACDOORYRK S1-ACDOORCOL S1-ACDOORLUX S1-ACDOORS1

170

DESCRIPTION

SIZE (INCHES)

STD. PKG.

PALLET QTY.

MLP

YO