Page 1

products >

Fan Coil Units

OUTSIDE HUMIDITY

35°C 45°C

90% 40%

22º C

Inside

PROVIDED BY HEINEN & HOPMAN

Heating

Ventilation

Air Conditioning

Refrigeration


Heinen & Hopman fan coils units are designed to operate in the marine industry where high standards are required.

EST

Fan Coil units Types

Green technology

- SIGMA: Fan coil unit with casing. Energy-saving technology is applied to Capacity: 0,6 kW - 11.72 kW our fan coil units to obtain extremely - PRISMA: Fan coil unit with low electrical absorption and a casing. Capacity: 0.6 kW - 3.90 kW continuous modulation of the air flow, - LOW BODY: Fan coil unit with or related to the energy needs in the without casing, designed for instalroom. lation in small niches. Capacity:Saving 0.6 Energy-saving istechnology is the EURAPO fan co EST (Energy Technology) applied to kW - 3.90 kW. composed by a brushless motor obtain extremely low electrical absorption and a continuous modulation - CONCEALED: Fan coil unit combined with an inverter, managed of-energybyinspecific the room. without casing. concrete Capacity: need 0.6 kW regulators. 11.72 kW. EST technology is composed by toa units brushless motor combined to a Compared with asynchronous - ATL: Fan coil unit designed for 3-speed motors, the fan coil units managed by specific regulators developed by EURAPO. Yacht sector. with brushless motors will reduce the In comparison to the traditional units equipped with asynchronous three - Custom made: Fan coil unit power consumption up to 70%. designed on customer request. units with brushless motors can obtain a considerable energy saving,

EST

to 70%.

“

Our mission: To ensure you the perfect climate indoors, regardless of the weather outside.

80%

80%

70%

70%

60%

60%

50%

50%

40%

40%

30%

30%

20%

20%

10%

10%

0%

0%

W

m3/h speed 6

speed 5

speed 4

speed 3

speed 2

speed 1

Asynchro Energy saving with EST fancoil

Thanks to the step-less modulation of the fan speeds it is possible to ac precise way, in strict relation to the real need of air conditioning in the ro

relative humidity are reduced at lowest level: a guarantee for the highe The possibility to reach very low air volumes makes the units extremely EST technology is designed in particular for offices, hospitals, nursing ho It is available for the EURAPO range of fan coil units, cassette units and

“


mod. SV/AF

mod. SV

mod. PV

mod. SV

FANCOIL UNIT

SIGMA fan coil units • Fan coil unit with casing • Heating and cooling applications • Capacity: 0.6 kW - 11.7 kW

SIGMA fan coils units can be used in all environments and for different applications. The fan coil units are highly reliable in performance. The fan coil units can be installed on the floor or on the ceiling in both configurations.

mod. SH/AF

Casing The casing, with upper air outlet, is made of sheet steel and painted with oven-dried epoxy powders, available in all RAL colors. The access doors and grilles are made of white heat-resistant ABS and can be turned into all four directions. The filter is fully retractable and easily accessible.

Models

Dimensions and weight

Model: SV - SV/AF - SH - SH/AF 110

112

114

216

218

A

648

773

898

1023

1148

B

538

538

538

538

110538112

114

614 216

218

614 222 220

224614226

228

773 538 224538

898 538

1023 254 538

1148 538

1273 1273 254 614 614

1523 1523 614 254614

1773 614 254

224 31

254 254 41263 44

SV---SH 648 A C

224

224

224

kg

18

20

23

224 B 28 SV - SH

233

233

233

kg

19

21

24

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

222

233 Kg

1273

31

224 224 C SV/AF---SH/AF C

220

Dimensions (mm) and weight for SV - SV/AF - SH - SH/AF 1273

41

224 23

224 28 263

224 1523

44

18 23320 SV/AF SH/AF 30 32 43 233 233 233 233 233 C 19 21 24 30 32 Kg HYDRAULIC CONNECTION 1/2” G F

46

263 43

226 1523

52

263 46

52

254 254 52 26352 263 54

54

614

263 54

254 58 263 61

263 54

228

Dimensions (mm) and weig 1773 614 110

112

648 773 A 254 560 560 B PV - PH 58 226 226 C 17 20 Kg 263 PV/AF - PH/AF 61 235 235 C 18 21 Kg HYDRAULIC CONNECTION


mod. SV

mod. SV/AF

mod. PV

mod. PV

mod. SV

PRISMA fan coil units

mod. PV/AF

A

C

FANCOIL UNIT

• Fan coil unit with casing • Heating and cooling applications (PV and PV/AF only) • Capacity: 0.6 kW - 3.9 kW

B

The PRISMA fan coil units have an original shape. The casing is a piece of furniture, made of painted metal sheet with side flaps and grilles made of ABS. The fan coil units can be installed on the floor or on the ceiling. The air intake can be located on the bottom or on the front in both configurations. mod. SH/AF

mod. PH/AF

Casing The casing, with upper air outlet, is made of sheet steel and painted with oven-dried epoxy powders, available in all RAL colors. The access doors and grilles are made of white heat-resistant ABS and can be turned into all four directions. The filter is fully retractable and easily accessible.

Models

Dimensions and weight

Model: PV - PV/AF - PH - PH/AF 110

112

114

216

218

A

648

773

898

1023

1148

B

560

560

560

560

560

226

226

PV-- --PH

Dimensions (mm) and weight for SV - SV/AF - SH - SH/AF C

kg

226

110

112

17

114

226

226

20

23

216PV/AF-218 220 222 --PH/AF

648 773 898 1023 1148 A 235 235 C 538 538 538 538 538 B 18 21 kg SV - SH 224 224 224 224 224 C 18 20 23 28 31 Kg SV/AF - SH/AF 233 233 233 233 233 C 19 21 24 30 32 Kg HYDRAULIC CONNECTION 1/2” G F

27

224

226

228

1273 1273 235 614 614

1523 614

1523 235 614

1773 614

254 41

254 44

254 52

254 52

254 58

263 43

263 46

263 54

263 54

263 61

24

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

28

31 235 32

Dimensions (mm) and weight for PV - PV/AF - PH - PH/AF

110

112

648 773 A 560 560 B PV - PH 226 226 C 17 20 Kg PV/AF - PH/AF 235 235 C 18 21 Kg HYDRAULIC CONNECTION 1/2” G F

114

216

218

898 560

1023 560

1148 560

226 23

226 27

226 31

235 24

235 28

235 32


mod. CVR mod. CV

LOW BODY fan coil units

mod. CVR

• Fan coil unit with casing • Heating and cooling applications • Capacity: 0.48 kW - 3.7 kW The LOW BODY fan coils units have a reduced height (427 mm) and can be installed in small niches. The low-body units have an upper air outlet and a front air intake. The fan coil units can be installed either on the floor or on the wall, or concealed. mod. SVR

Casing The inner frame is made of galvanized steel. The casing is made of sheet steel and painted with oven-dried epoxy powders, available in all RAL colors. The access doors and grilles are made of white heat-resistant ABS and can be turned into all four directions.

Models

Dimensions and weight

Model: CVR 110

112

114

216

218

A

555

680

805

930

1055

B

395

395

395

395

C

230

230

230

230

kg

9

11

14

16

Model: SVR 110

112

114

216

A

648

773

898

1023

B

430

430

430

430

C

254

254

254

254

kg

15

17

22

23

395

Dimensions 230 (mm) and weight CVR 19

110

112

555 680 A 395 395 B 230 230 C 9 11 Kg 218 HYDRAULIC CONNECTION 1/2” G F

Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

114

216

218

805 395 230 14

930 395 230 16

1055 395 230 19

1148

430 (mm) and weight SVR Dimensions 254 26110

112

648 773 A 430 430 B 254 254 C 15 17 Kg HYDRAULIC CONNECTION 1/2” G F

Alternatives available on request.

Dimensions (mm

114

216

218

898 430 254 22

1023 430 254 23

1148 430 254 26

110

CV - CH 555 A CV/AF -CH/AF 574 A CV - CV/AF - CH 505 B 215 C 10 Kg HYDRAULIC CON


mod. CV

CONCEALED fan coil units

mod. CV/AF

mod. CV/AF

mod. CVR

• Fan coil unit without casing • Heating and cooling applications • Capacity: 0.6 kW - 11.72 kW The CONCEALED fan coils units can be used for ductwork installations. The fan coil units are highly reliable in performance, silent and can be equipped with a wide range of accessories. The fan coil units can be installed vertically, on the wall (with bottom air intake) or on the floor (with front air mod. SVR intake), and horizontally, on the ceiling (with bottom or rear air intake). The fan coil units are the ideal solution for the needs of small spaces and limited sizes that influence the choice of furniture in homes or offices.

mod. CH

Casing Available in ten sizes, the concealed model has an electric box with terminal board and auxiliary drain pan. The frame is made of galvanized steel. The inner sides are completely lined with an insulating self-extinguishing material.

Models

Dimensions and weight

Model: CV - CV/AF - CH - CH/AF

Dimensions (mm) and weight110 CVR

110

A

112

555

555 680 A 395 395 B A230 230 574 C 9 11 Kg HYDRAULIC 505G F B CONNECTION 1/2” C

112

114 805 395 230 14

215

Dimensions SVR kg (mm) and weight 10

110

112

648 773 A 430 430 B 254 254 C 15 17 Kg HYDRAULIC CONNECTION 1/2” G F

680 699

114

216 930 395 230 16

218

805

1055 395 824 230 CV-19

505

505

215

215

13

16

114

216

218

898 430 254 22

1023 430 254 23

1148 430 254 26

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

216

Dimensions - CH - CH/AF 218 (mm) and weight 220 for CV - CV/AF 222

CV-- --CH 930

110

1055

112

114

1180

216

CV - CH CV / AF-- --CH / AF 555 680 805 930 A 949 1199 CV/AF1074 -CH/AF --CV / AF A--CH---------CH 574 699 824/ AF 949 CV - CV/AF 505 505 - CH - CH/AF581 505 505 505 B 215 215 245 505 215 215 215 C 19 22215 29 10 13 16 19 Kg HYDRAULIC CONNECTION 1/2” G F

218

220

222

1055

1180

1180

1074

1199

1199

1180 1199 581

505 245581 215 31 245 22 29

224

226

224

226

228

1430

1430

1680

1449

1449

1699 581

581

581 245 38

581245 24538 42

245

1430 1449 581

581 245 31

228

581 245 245 38 38

1430 1449

1680 1699

42


TECHNICAL DATA (3 rows - Energy saving technology)

Air temperature: 27 0C d.b., 19 0C w.b. Water temperature: 7 / 12 0C Air temperature: 20 0C Water inlet temperature: 50 0C Air temperature: 20 0C Water inlet temperature: 70 / 60 0C

Heating

Heating

Cooling

112

Total cooling capacity (kW)

Sensible cooling capacity (kW)

Water flow (l/h)

Pressure drop (kPa)

Heating capacity (kW)

Heating capacity (kW)

Water flow (l/h)

Pressure drop (kPa)

Further data

Air volume (m3/h)

Sound power level (dB[A])

Sound pressure level (dB[A]) (1)

216

220

222

224

228 10.50

9V

1.91

2.90

3.60

5.01

6.06

8.11

6V

1.35

2.15

2.55

3.75

4.50

5.71

7.30

3V

0.63

1.02

1.18

1.98

2.03

3.21

4.30

9V

1.57

2.39

2.84

4.04

4.97

6.49

7.90

6V

1.08

1.70

1.92

2.91

3.55

4.57

5.40

3V

0.49

0.49

0.91

1.50

1.61

2.45

3.00

9V

328

498

618

860

1120

1392

1802

6V

232

369

438

643

793

980

1253

3V

108

175

202

340

408

551

738

9V

8.90

8.40

13.20

28.30

17.10

24.10

42.30

6V

4.80

4.70

7.30

17.40

8.40

12.90

25.00

3V

1.40

1.60

1.80

5.60

7.70

4.30

10.20 10.80

9V

2.64

4.08

5.16

6.35

8.01

9.92

6V

1.90

2.71

3.77

4.72

5.49

6.71

8.20

3V

0.98

1.27

2.07

2.42

2.76

4.22

5.30

Water flow (l/h) Pressure drop (kW)

114

Value as Cooling accordingly to the Eurovent Standards and UNI ENV 1397 Norm 9V

3.70

7.30

12.90

23.30

26.00

22.80

39.80

6V

2.60

3.50

7.10

17.60

7.20

10.70

23.00

3V

2.10

1.50

1.80

4.40

6.30

3.50

8.70

9V

4.56

7.04

8.85

10.76

13.84

16.73

17.84 13.68

6V

3.27

4.61

6.52

7.97

10.13

11.24

3V

1.69

2.17

3.57

4.06

5.24

7.11

8.91

9V

400

619

777

945

1216

1469

1566 1202

6V

287

405

572

700

890

987

3V

149

190

314

357

460

625

783

9V

5.30

10.70

19.20

26.80

33.00

24.30

29.70 20.50

6V

3.80

4.00

11.30

19.80

8.60

10.50

3V

3.70

1.70

3.80

4.60

7.60

4.20

9.30

9V

432

583

791

1010

1305

1828

2050

6V

286

379

523

675

857

1200

1330

3V

128

172

248

323

403

582

620

9V

56

57

61

57

63

67

70

6V

45

49

50

46

57

57

61

3V

31

30

34

30

37

45

41

9V

46

48

51

48

53

58

60

6V

36

40

41

37

48

48

52

3V

30*

30*

30*

30*

30*

36

32

Power input (W) (2)

9V

31

48

52

50

104

170

230

Absorbed current (A) (2)

9V

0.28

0.42

0.46

0.44

0.88

1.37

1.70

Water content (l)

V

0.79

1.05

1.31

2.20

2.20

2.84

3.47

(1) Sound pressure level in a 100 m3 room, at a 1.5m distance and with a reverberating time of 0.3 s. (2) Electrical supply: 230-1-50 [V-ph-Hz]. * Minimum value measurable in laboratory, indicated by Eurovent.

NOTE: Performances of LOW BODY models are about 11% lower than the standard ones in heating operation and 12,3% lower in cooling operation. For greater accuracy please contact Heinen Hopman. To obtain capacities for 2 or 4 row coils, or for conditions different from standard ones, please contact our staff. The printed data could be modified without any notice.


TECHNICAL DATA (3 rows - asynchronous)

Air temperature: 27 0C d.b., 19 0C w.b. Water temperature: 7 / 12 0C Air temperature: 20 0C Water inlet temperature: 50 0C Air temperature: 20 0C Water inlet temperature: 70 / 60 0C

Heating

Heating

Cooling

110

Total cooling capacity (kW)

Sensible cooling capacity (kW)

Water flow (l/h)

Pressure drop (kPa)

Heating capacity (kW)

Heating capacity (kW)

Water flow (l/h)

Pressure drop (kPa)

Further data

Air volume (m3/h)

Sound power level (dB[A])

Sound pressure level (dB[A]) (1)

114

216

218

220

222

224

226

228

MAX

1.16

1.64

2.20

3.36

3.58

4.53

5.19

6.57

7.41

9.50

MED

0.99

1.35

1.92

2.72

3.05

3.75

4.48

5.87

6.81

7.75

MIN

0.79

1.10

1.60

2.24

2.50

2.99

3.91

4.70

5.61

6.18

MAX

0.98

1.30

1.96

2.52

3.14

3.62

4.54

5.20

5.86

7.02

MED

0.82

1.03

1.68

2.00

2.57

2.91

3.83

4.56

5.32

5.53

MIN

0.64

0.82

1.36

1.60

2.04

2.25

3.27

3.53

4.26

4.27

MAX

199

281

414

577

614

777

891

1127

1271

1630

MED

170

232

360

467

524

643

769

1007

1168

1330

MIN

136

189

300

366

429

513

671

806

963

1060

MAX

3.40

7.10

5.80

14.80

13.60

24.10

28.40

18.80

21.00

16.90

MED

2.80

5.00

4.60

12.50

9.80

17.40

21.80

15.50

18.10

25.80

MIN

2.00

3.40

3.30

8.50

6.70

11.60

17.20

10.50

12.80

17.30 10.70

MAX

1.57

2.16

3.05

4.11

4.95

5.74

7.19

7.83

9.33

MED

1.28

1.73

2.43

3.44

4.16

4.65

6.08

6.94

8.51

8.60

MIN

1.00

1.35

2.00

2.75

3.35

3.61

5.25

5.45

6.86

6.74

Water flow (l/h) Pressure drop (kW)

112

Value as Cooling accordingly to the Eurovent Standards and UNI ENV 1397 Norm MAX

2.70

6.10

4.80

11.90

12.50

20.00

23.50

15.50

20.50

34.60

MED

2.30

4.70

3.70

8.50

9.10

14.30

18.00

12.70

17.60

24.20

MIN

1.70

3.10

2.80

5.70

6.30

9.50

14.20

8.70

12.40

16.30

MAX

2.74

3.70

5.20

6.93

8.48

9.64

12.25

13.19

15.77

17.83

MED

2.23

2.94

4.09

5.82

7.12

7.85

10.32

11.66

14.38

14.35

MIN

1.74

2.28

3.37

4.65

5.71

6.04

8.93

9.15

11.58

11.22

MAX

241

325

456

608

745

847

1076

1159

1385

1566

MED

196

258

359

511

625

689

907

1024

1263

1260

MIN

153

201

396

408

502

531

784

804

1017

985

MAX

2.80

7.80

5.60

12.70

17.30

22.60

32.20

15.70

23.10

30.90

MED

2.90

5.60

3.60

9.80

12.20

15.60

23.50

12.60

19.60

21.10

MIN

2.10

3.40

2.60

6.20

8.10

9.70

18.20

8.30

13.20

13.70

MAX

245

320

436

580

709

856

1074

1254

1481

1687

MED

191

249

358

456

592

676

920

1113

1352

1151 838

MIN

144

194

289

338

474

527

739

797

999

MAX

48

50

54

53

55

54

60

60

63

67

MED

42

45

49

47

50

48

56

55

60

60

MIN

36

38

42

40

43

40

50

47

53

55

MAX

39

41

44

44

46

44

50

49

53

57 50

MED

33

36

39

38

42

38

45

47

54

MIN

30

30

33

31

34

31

40

40

44

45

Power input (W) (2)

MAX

46

45

57

61

86

90

117

140

162

178

Absorbed current (A) (2)

MAX

Water content (l)

0.23

0.23

0.26

0.29

0.33

0.38

0.52

0.65

0.65

1.04

0.53

0.79

1.05

1.31

1.57

2.20

2.20

2.84

2.84

3.47

(1) Sound pressure level in a 100 m3 room, at a 1.5m distance and with a reverberating time of 0.3 s. (2) Electrical supply: 230-1-50 [V-ph-Hz]. * Minimum value measurable in laboratory, indicated by Eurovent.


ATL-DC low profile fan coil units

Model

The ATL-DC fan coil units are used in areas with reduced heights and an excellent choice for the yacht sector. The ATL-DC units represents an improved design approach to  low profile, allow easier maintenance access and reduced dimensions overall. The drain pan has an anti-slosh, anti-fungal foam lining and extends to under the valve motor and plumbing. The water  connections are insulated against secondary condensation.    The valve can be installed to the left or to theright.         Advantages          •  Blowers are extremely silent yet powerful enough to      overcome high-static-pressure duct;    •  Improved design for easy servicing, smaller dimensions;    •  Top panel is removable for easier access;     •  Dual blowers are installed horizontally for exceptionally        low profile;    •  Suspension from above or support from beneath   (hardware included);    •  Internal components are insulated against secondary     condensation;     •  Vibration isolationmounts reduce noise and vibration;     •  Bypass valve has removable power head for easy servicing;    •  Optional flow control automatically balances circulated  

water throughout the system. • Optional electric heater

ATL6DC

ATL9DC

ATL12DC

ATL18DC

ATL24DC

ATL36DC

Capacity (kW)

1.76

2.64

3.52

5.27

7.03

10.54

V @ 50/60Hz / 1-Phase

230

230

230

230

230

230

Amps (FLA) Cool

1.4

1.4

2.8

2.8

3.9

7.8

1.4 1.4 

Amps (FLA) Blower Optional heater (kW)

(1)

Heater Amps (A) Max. Circuit breaker (A)   breaker (A)  Min. Circuit 



Water flow  (GPM / I / min)    Air flow (CFM / m3/h) (2)    / Pa) External static pressure (H20   Height deck mount (in / mm) (3)   Height suspension mount (in / mm) (3)    Max. Width (in / mm) (3)   (3) Depth without mm)  heat (in /    Depth with heat (in / mm) (3)   Drain connection type     Drain connection  size   Chilled water connectiontype   Chilled water connection size    Quantity duct connections (in/mm)     Minimum supply duct size (in/mm) (4)  

Minimum supply air grill size (in / cm ) 2

2

Total return air inlet (in2 / cm2)

 

Pan style

 Dimensions

2.8

2.8

1.5

3

1

1

1.5

1.5

1.5

3

5.7

5.7

11.5

11.5

8

16

5

5

   2  2   1.5 / 5.7 2.25 / 8.6    200 / 340 233 / 396     1.75 / 435 0.6 / 149   8 / 204  8 / 204    8.2 / 209 8.2 / 209     19.6 / 498 19.6 / 498   19.7 / 501 19.7 / 501    25.4 / 646  25.4 / 646   FPT  tube stubs   ½” ½”     FPT FPT   ½”  ½”    1 1    4 / 102  6 / 153  





    



 

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

5

30

5

23

3 / 11.4

4.5 / 17.1

6 / 22.8

9 / 34.1

350 / 595

467 / 793

670 / 1139

1000 / 1700

1.75 / 435

0.6 / 149

0.3 / 75

0.3 / 75

8 / 204

8 / 204

10 / 254

10 / 254

8.2 / 209

8.2 / 209

10.1 / 257

10.1 / 257

31.5 / 801

31.5 / 801

43.8 / 1113

61.8 / 1570

17.9 / 455

17.9 / 455

20.5 / 521

20.5 / 521

23.6 / 600

23.6 / 600

26.2 / 666

26.2 / 666

tube stubs

tube stubs

tube stubs

tube stubs

½”

½”

½”

½”

FPT

FPT

FPT

FPT

½”

½”

½”

½”

2

2

1

2

6 / 153

7 / 178

9 / 229

10 / 254

49 / 316

35 / 226

49 / 316

147 / 949

168 / 1084

70 / 452

98 / 633

130 / 839

200 / 1291

240 / 1549

360 / 2323

Sloped

Sloped

Sloped

Sloped

Sloped

Sloped

 

 

5 4

35 / 226

1.5kW is recommended for the ATL24 because it has one blower. 2kW is maximum. Air flow data is for units without electric heat. Electric heat reduces air flow by amount to be determined. 3 All dimensions ±0.3 inch (8mm). 4 ATL 12, ATL18 and ATL36 models have dual blowers and therefore two supply duct rings. 1



5 4

2






ATL-HV low profile fan coil units

Model

ATL6 HV

 1.76   230 V @ 50/60Hz/ 1-Phase    Amps (FLA) Cool    0.9       0.7 Amps (FLA) Blower      (1) 1 Optional heater  (kW)   Heater Amps (A)   5   5 Max. Circuit breaker  (A)      2 Min. Circuit breaker (A)                         / I / min)    1.5 / 5.7 Water flow (GPM Advantages               (2)     Air flow (CFM   200 / 340  / m3/h)                 0.3 / 75 External static pressure (H20 / Pa) • Blowers are extremely quiet yet powerful enough to   overcome high               (3) 8 / 204     (in / mm) Height deck mount static-pressure duct;           (3) • Suspension from above or support from beneath (hardware included); 8.1 / 206 Height suspension / mm)           mount (in       • Internal components are insulated against condensation;  secondary    / mm) (3)  19.6 / 498 Max. Width (in             • Vibration isolation  mounts reduce noise and vibration; (3)     18 / 458 Depth without heat (in / mm)              • Bypass valve has removable power head for easy servicing;     (3) 23.7 / 602 Depth with heat (in / mm)            • Automatically flow control helps balance chilled water distrubution       tube stubs Drain connection type       throughout theboat.      size  ½” Drain connection • Optional electric heater         FPT Chilled water connection type             ½” Chilled water connection size        1 Quantity duct connections (in/mm)         Dimensions       (4) Minimum supply duct size (in/mm)    4 / 102         2 2       35 / 226 Minimum supply air grill size (in / cm ) 







The ATL-HV fan coil units are ideal for height-restrictive    installations;   improved design  high velocity blowers. The ATL-HV units  represents an     approach to low profile, allow easier maintenance access and reduced          dimensions overall.      The drain pan has an anti-slosh, anti-fungal foam lining and extends     to under the valve motor and plumbing. The water connections are    The valve  to insulated against secondary condensation. can be installed      the left or to the right.        

 Capacity (kW)

 Total return air inlet (in2 / cm2)

  



  

  

  

 

  

 Alternatives available on request.

 



  

 

  

3



 



Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

 



3.52

5.27

7.03

230

115

230

230

115

230

0.6

3.12

1.8

1.8

2.3

1.15

0.5

3.2

1.4

1

3.4

1.3

2 20.6

2 10.1

5 4

9.7

1.5 16.4

5 3

3

7.8 5

3

2

2.25 / 8.6

3 / 11.4

4.5 / 17.1

6 / 22.8

233 / 396

350 / 595

467 / 793

730 / 1241

0.3 / 75

0.3 / 75

0.3 / 75

0.3 / 75

8 / 204

8.1 / 206

8.1 / 206

10 / 254

8.1 / 206

8.1 / 206

8.1 / 206

10.1 / 257

19.6 / 498

31.6 / 803

31.6 / 803

42.9 / 1090

19.7 / 501

17.9 / 455

25.5 / 648

22 / 559

25.4 / 646

23.6 / 600

19.8 / 503

27.7 / 704

FPT

tube stubs

tube stubs

tube stubs

½”

½”

½”

½”

FPT

FPT

FPT

FPT

½”

½”

½”

½”

1

2

2

1

6 / 153

6 / 153

7 / 178

9 / 229

49 / 316

35 / 226

49 / 316

147 / 949

98 / 633

130 / 839

200 / 1291

240 / 1549

Sloped

Sloped

Sloped

Sloped

1.5kW is recommended for the ATL24 because it has one blower. 2kW is maximum. Air flow data is for units without electric heat. All dimensions ±0.3 inch (8mm). 4 ATL 12, ATL18 and ATL36 models have dual blowers and therefore two supply duct rings. 2

 

2.64

5

70 / 452 



ATL24HV

1

Sloped

 

ATL18HV

4.8

1

 



ATL12HV

1



Pan style

ATL9 HV


AU-DC fan coil units

Model

The AU-DC fan coil units are designed for easy installation and high performance. AU-DC models feature ultra-quite blowers that are strong enough to overcome high static pressure. The composite drain pan quickly removes condensate water. Each drain hole is reinforced and has  an external stop to prevent over tightening of the screw-in hose barb. Straight or 90-degree hose barbs may be used to better accommodate a variety of installation situations. The blower inlet adapter is made of a high     by the optional temperature resin to easy withstand the heat generated     internal electric heating element.  The manual heater-overload safety switch      without disassembling  is easily accessible the unit.

   

AU18DC

AU24DC

2.64

3.52

5.27

7.03

230

230

230

230

230

Amps (FLA) Cool

1.4

1.4

3.17

3.9

3.86

Amps (FLA) Blower

1.4

1.4

3.2

3.9

3.9

Max. Circuit breaker (A) Min. Circuit breaker (A)

1

1

1.5

3

3

5.75

7.92

9.69

17

16.9

10

10

15

20

20

7

9

11

18

18

Water flow (GPM / I / min)

1.5 / 5.7

2.25 / 8.6

3 / 11.4

4.5 / 17.1

6 / 22.8

Air flow (CFM / m3/h)

200 / 340

300 / 510

400 / 680

600 / 1020

700 / 1170

External static pressure (H20 / Pa)

2.9 / 722.1

2.8 / 697.2

2.6 / 647.4

2.1 / 522.9

1.4 / 348.6

1.1

4.4

8

4.6

11

Max. Height (in / mm)

(2)

11.7/298

13.4 / 341

13.4 / 341

14.4 / 366

15.5 / 394

Max. Width (in / mm)

(2)

14.4/366

16.4 / 417

16.4 / 417

19.9 / 506

22.4 / 569

Max. Depth (in / mm)

(2)

14/356

14 / 356

16.7 / 425

17.3 / 440

17.3 / 440

Drain connection type

FPT

FPT

FPT

FPT

FPT

Drain connection size

½”

½”

½”

½”

½”

Chilled water pressure drop (PS)

Chilled water connection type

FPT

FPT

FPT

FPT

FPT

Chilled water connection size

½”

½”

½”

½”

½”

Quantity duct connections (in/mm)

1

1

2

2

1

Minimum supply duct size (in/mm)

5 / 125

6 / 153

6 / 153

7 / 178

8 / 204

Minimum supply air grill size (in2 / cm2)

35 / 226

49 / 319

70 / 452

100 / 646

140 / 904

Total return air inlet (in2 / cm2)

70 / 452

98 / 633

130 / 839

200 / 1291

240 / 1549

Gross Weight (lbs/kg)

31 / 14.1

35 / 15.9

42 / 19.1

54 / 24.5

58 / 26.4

(3)

Model numbers shown are for 115V units with brushless blowers. Add a ‘Z’ for 230V units; add a ‘FC’ for optional control; add a ‘-L’ or ‘-R’ for valve position (relative to the coil) and angle of the blower; add a ‘_kW’ for amount of optional electric heat in kW (for ex. 1.5kW) 2 All dimensions ±0.3 inch (8mm). 3 Without electric heat option, subtract 3lbs (1.4kg) from unit weight for each heater element.

 



AU12DC

1.76

1



   

AU9DC

Capacity (kW)

Optional heater (kW)

• Optional EU package upgrades includes several upgrades for reduced installation time and improved appearance (contact us for more details).

AU6DC

V @ 50/60Hz / 1-Phase

Heater Amps (A)

        Advantages            • Rust-free composite   drain pan    anti-slosh, ‘positive-flow’   • Drain pan features drain channels for no spills     and rapid removal of condensate;       • Blowers are extremely quiet yet powerful enough to overcome     high-static-pressure duct;     • Single adjustment   screw for 270°  of blower rotation;    down position • Blower can be  rotated to straight for overhead applications;     • Vibration isolation mounts reduce noise and vibration;      options;   • Flexible mounting   automatically   water throughout • Optional flow control balances circulated     the system.         • Optional electric heater

Dimensions 

(1)



Alternatives available on request. Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.


AU-HV fan coil units

Model

The AU-HV fan coil units are designed for easy installation and high performance. The AU-HV fan coil units feature high velocity (HV) blowers. The positive flow drain pan quickly removes condensate water. Each drain hole is reinforced and has an external stop to prevent over tightening of the screw-in hose barb. To be better accommodate a variety of installation, each drain can accept either a straight or 90° hose barb. Due to the rotatable blower ring, the blower can be rotated easily 270°.  The blower inlet adapter is made of a high temperature resin to easy withstand the heat generated by the optional internal electric heating element. The manual heater-overload safety switch is easily accessible without disassembling the unit.     

 

   

            Advantages               pan  • Rust-free composite drain       • Drain pan features anti-slosh, ‘positive-flow’ drain channels for no spills       and rapid removal of condensate;    • Single adjustment screw for 270° of blower  rotation;    • Blower can be rotated to straight down position for overhead applications;     isolation mounts  • Vibration reduce noise and  vibration;    • Flexible mounting options;    • Optional balances  circulated water throughout flow control automatically    thesystem.    • Optional  electric heater   EU package upgrades  includes several  • Optional upgrades for reduced

Capacity (kW)



2.64

AU18HV

3.52

AU24HV

5.27

7.03

115

230

115

230

115

230

115

230

115

Amps (FLA) Cool

00.83

1.56

0.61

1.14

0.78

1.61

2.52

1.18

1.64

3.4

Amps (FLA) Blower

5.18

10.26

4.96

9.84

7.3

14.65

28.61

14.22

14.68

29.49

Optional heater (kW)

1

1.5

1.5

3

3

Max. Circuit breaker (A)

10

15

10

15

10

20

30

15

20

35

Min. Circuit breaker (A)

6

11

6

11

8

16

30

15

16

31

Water flow (GPM / I / min)

1.5 / 5.7

2.3 / 8.8

3 / 11.4

4.5 / 17.1

6 / 22.8

Air flow (CFM / m3/h)

229 / 390

278 / 473

338 / 575

465 / 791

506 / 860

0.3 / 75

0.3 / 75

0.3 / 75

0.3 / 75

0.3 / 75

External static pressure (H20 / Pa) Chilled water pressure drop (PS)

1.1

4.4

8

4.6

11

Min. Height (in / mm) (2)

11.19 / 285

13.31 / 339

13.31 / 339

13.94 / 355

15.25 / 388

Max. Height (in / mm)

(2)

12.13 / 309

13.31 / 339

13.38 / 340

15.38 / 391

16.75 / 426

Max. Width (in / mm)

(2)

14.5 / 369

16.5 / 420

16.5 / 420

20.13 / 512

22.63 / 575

Max. Depth (in / mm)

(2)

12.65 / 320

13.25 / 337

14.25 / 362

15 / 381

15.38 / 391

½”

½”

½”

½”

½”

5 / 127

6 / 153

6 / 153

7 / 178

8 / 204

Minimum supply air grill size (in / cm )

35 / 226

49 / 316

70 / 452

100 / 646

140 / 904

Minimum return air inlet (in2 / cm2)

70 / 452

98 / 633

130 / 839

200 / 1291

240 / 1549

Drain connection size (in) Minimum supply duct size (in/mm) 2

2

Model numbers shown are for 115V units with high velocity blowers. Add a ‘Z’ for 23V units; add a ‘FC’ for optional control; add a ‘-L’ or ‘-R’ for valve position (relative to the coil) and angle of the blower; add a ‘_kW’ for amount of optional electric heat in kW (for ex. 1.5kW) All dimensions ±0.3 inch (8mm).

1

2



   

AU12HV

230

Dimensions 

 

AU9 HV

1.76

V @ 50/60Hz / 1-Phase

installation time and improved appearance (contact us for more details) • Optional air purifier (microparticle air filter)

   

AU6 HV

(1)

 



Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.


FC marine fan coil unit • Nominal cooling loads: 10 kW - 70 kW • Spigoted duct connection • Electro-coated mild-steel casing with powder-coated paint finish • Removable front panels for access and maintenance • Quick-release grille for air filter cleaning and replacement • Electrical supply o 380V 3ph 50Hz o 440V 3ph 60Hz • Available options o Plenum and Grille discharge o Color to suit operating environment o Alternative fan pressures o Electric or hot-water heating o Fresh-air connection o Stainless-steel casing

FC10 Nominal cooling load (kW) Nominal air flow (m3/h)

FC15

FC20

FC30

FC40

FC50

FC70

10

15

20

30

40

50

70

1600

2600

3600

4800

6300

8000

11250 2.78

Nominal water flow (m3/h)

0.4

0.6

0.79

1.19

1.59

1.98

Fan motor rating

0.37

0.55

0.75

1.10

1.50

1.50

2.20

Dimensions H (mm)

1500

1750

1750

1750

1750

2000

2000

W (mm)

500

700

700

700

1200

1200

1500

D (mm)

500

750

750

750

750

750

750

P (mm)

260

270

330

340

340

400

450

Weight (kg) Electric heating (optional) (kW)

121

168

185

221

278

303

372

1 x 4.5

2 x 4.5

2 x 6.0

2 x 9.0

2 x 9.0

3 x 9.0

4 x 9.0

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.


Brazil T: +55 213 587 4241/4244 E: info@br.heinenhopman.com France - La Ciotat T: +33 4 4204 8685 E: info@heinenhopmanfrance.com France - Antibes T: +33 6 3090 7786 E: info@heinenhopmanfrance.com Germany T:+49 4073 1680 E: info@drewsmarine.com

Germany T:+49 471 9869 300 E: info@moehringms.com India T: +91 336 499 1293 E: info@heinenhopmanindia.com Italy T: +39 018 745 7970 E: info@it.heinenhopman.com The Netherlands (HQ) T: +31 33 299 2500 E: info@heinenhopman.com

The Netherlands (Rotterdam) T: +31 78 890 8050 E: binnenvaart@heinenhopman.nl Norway T: +47 6919 0900 E: admin@teknotherm.no People’s Republic of China T: +86 213 253 2896 E: info@cn.heinenhopman.com People’s Republic of China T: +86 510 8528 1763 E: xue.han@teknotherm.no

Poland T: +48 914 331 800 E: tmh@teknotherm.no Romania T: +40 236 448 222 E: office@ro.heinenhopman.com Russia T: +7 (4012) 308 801 E: info@heinenhopman.ru Singapore T: +65 6897 7879 E: info@sg.heinenhopman.com

South Korea T: +82 704 901 0000 E: info@kr.heinenhopman.com Spain T: +34 932 259 668 E: info@es.heinenhopman.com Sweden T: +46 3121 7500 E: mats.uden@teknotherm.no Turkey T: +90 216 493 8118 E: info@tr.heinenhopman.com

UAE (Abu Dhabi) T:+971 2550 4147 E: info@caspuae.com UAE (Dubai) T: +971 4263 5453 E: info@caspuae.com USA - Fort Lauderdale, Florida T: +1 954 463 0110 E: info@arwmaritime.com USA - Houma, Louisiana T: +1 985 876 7982 E: leblanc@leblancandassociates.com

Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions. Visit greenmanifest.info for more information.

www.heinenhopman.com

Fan coil units fcu  

Heinen & Hopman fan coils units are designed to operate in the marine industry where high standards are required.

Fan coil units fcu  

Heinen & Hopman fan coils units are designed to operate in the marine industry where high standards are required.