Issuu on Google+

1

2

3

4

5

6

7

8

9

10

11

12

GENERAL NOTES 150

250

A

DOWNLIGHTS CENTRED ON VERTICAL PANELLING

85

1/ CONTRACTOR SHALL SITE VERIFY ALL EXISITING CONDITIONS AND CRITICAL DIMENSIONS PRIOR TO COMMENCEMENT OF WORK, AND SHALL NOTIFY CLIENT, DESIGNER OF ANY DISCREPENCIES PRIOR TO PROCEEDING WITH WORK

1900mm FROM FINSIHED FLOOR LEVEL TO BOTTOM OF BULB CAP FITTING

CH=2800mm AFF

265

2000mm FROM FINSIHED FLOOR LEVEL TO BOTTOM OF BULB CAP FITTING

D1

P1

2/ BY THE USE OF THESE DRAWINGS FOR CONSTRUCTION OF THE PROJECT THE CLIENT REPRESENTS THAT HE HAS REVIEWED AND APPROVED THE DRAWINGS, AND THAT THE CONSTRUCTION DOCUMENT PHASE HAS BEEN COMPLETED

CH=2300mm AFF

CH=2375mm AFF

B

P1

1900mm FROM FINSIHED FLOOR LEVEL TO BOTTOM OF BULB CAP FITTING

CH=2800mm AFF CH=2400mm AFF

350

2000mm FROM FINSIHED FLOOR LEVEL TO BOTTOM OF BULB CAP FITTING

P1

CH=2400mm AFF

D1

350

CH=2600mm AFF

P1 P1

2000mm FROM FINSIHED FLOOR LEVEL TO BOTTOM OF BULB CAP FITTING

1900mm FROM FINSIHED FLOOR LEVEL TO BOTTOM OF BULB CAP FITTING

CH=2800mm AFF

SERVERY

D1

CH=2400mm AFF

CH=2800mm AFF

3/ THE CONTRACTOR SHALL ADHERE TO THE DRAWINGS AND SPECIFICATIONS, SHOULD ANY ERROR OR INCONSISTENCY APPEAR REGARDING THE TRUE MEANING AND/OR INTENT OF THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL IMMEDIATELY REPORT TO DESIGNER WHO WILL MAKE ANY NECESSARY CLARIFICATION, INTERPRETATION, OR REVISION AS REQUIRED.

D1

5/ IF THE CONTRACTOR DISCOVERS AN ERROR OR INCONSITENCY AND PROCEEDS WITH WORK WITHOUT NOTIFYING THE DESIGNER OF ANY SUCH DISCREPENCIES, HE SHALL ASSUME ALL CHARGES AND MAKE ANY CHANGES TO HIS WORK MADE NECESSARY BY HIS FAILURE TO OBSERVE AND/OR REPORT THE CONDITION.

D1 REFLECTED CEILING PLAN

DEATILED VIEW OF PENDANT LOCATION

Scale: 1:100

C

Scale: 1:25

6/ IF THE INTENT OF THE DRAWINGS AND SEPCIFICATIONS ARE UNCLEAR, THE CONTRACTOR SHALL ASK THE DDSIGNER FOR CLARIFICATION, PRIOR TO PROCEEDING WITH WORK, IN THE FORM OF A WRITTEN REQUEST FOR INFORMATION. THE DESIGNER SHALL THEN RESPOND IN WRITING TO ALL APPROPRIATE PARTIES.

DETAILED VIEW OF BACK BAR 595

1300

Scale: 1:25

2800

640

640

640

1100

D3

640

D

905

CH=2800mm AFF D2

E

P4 D2

D2

D2

D2

8/ KEEP CLEAN ALL EXISTING SPACES AND DO NOT ALLOW MATERIALS AND DEBRIS GEENRATED BY DEMOLITION ACTIVTIES TO ACCUMULATE ON SITE, REMOVE DAILY AND DISPOSE OF IN A LEGAL MANNER.

D2 D2

645

D2

460

1700

D

640

635

1005

655

D2

SP

P1

D2

HL

D2

D2 D1

405

980

350

1580

D2

SP

D2

D2

11/ PROVIDE ADEQUATE SHORING AND BRACING OF EXISITNG MASONARY WALLS (BEARING AND NON-BEARING) TO RECIEVE NEW OPENINGS.

D2

SP

D2

CH=2600mm AFF

D2

CH=2400mm AFF D2

D2 D2

D2

D2

LEGEND

420

CH=2400mm AFF

GM D3

E

SERVICE STATION

D3

STORAGE

D2

450

D2

FEMALE TOILETS

F

F

D2

STORAGE

ADJUSTABLE DIMMABLE DOWNLIGHT

D1

D2

CH=2400mm AFF

ADJUSTABLE DIMMABLE DOWNLIGHT

D2

REF: TO BE AGREED BEFORE WORK COMMENCES CONTRACTOR TO PROVIDE OPTIONS

CH=2800mm AFF

350

REF: TO BE AGREED BEFORE WORK COMMENCES CONTRACTOR TO PROVIDE OPTIONS

.........MM AFF

P1

CEILING HEIGHT

XXX

REF: TO BE AGREED BEFORE WORK COMMENCES CONTRACTOR TO PROVIDE OPTIONS

970

3350

HL

DOUBLE ADJUSTABLE DOWNLIGHT

D3

205

HEAT LAMP

REF: TO BE AGREED BEFORE WORK COMMENCES CONTRACTOR TO PROVIDE OPTIONS

D2

CH=2800mm AFF

PENDANT

P2

PENDANT

CENTRE LINES

FEATURE PENDANT MOOI NON-RANDOM

REFLECTED CEILING PLAN

SMOKE DETECTOR

E

CONSTRUCTION NOTES

H

LIGHTING CIRCUITS

Scale: 1:50

REVISION

A

ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED ON SITE AND ANY DISCREPENCIES SHOULD BE REFERRED TO MB DESIGN FOR THEIR DIRECTION. MB DESIGN WILL NOT BE HELD LIABLE WHEN FAILURE TO IMPLEMENT THIS REFERRAL OCCURS. WORK TO FIGURED DIMENSIONS ONLY. DO NOT SCALE OFF DRAWINGS.

1

2

PROPRIETARY TO BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURERS INSTRUCTIONS. SIZES OF ALL PROPRIETARY ITEMS SHALL BE CHECKED WITH THE MANUFACTURER. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO ENSURE THAT ALL MATERIALS AND WORKMANSHIP COMPLY

3

DATE

28/09/10

NOTES

PROJECT TITLE

REVISION TO LIGHTING ABOVE FIXED SEATING AND ADJACENT FITING - NOW DOWNLIGHTS. ADDITION OF LIGHT TO STORE

WITH THE RELEVANT REGULATIONS AND THAT ALL HEALTH AND SAFETY REGULATIONS ARE IMPLEMENTED. THESE DRAWINGS ARE COPYRIGHT AND REMAIN THE PROPERTY OF MB DESIGN. NO WORK NOR DESIGNS ON THESE DRAWINGS MAY BE REPRODUCED WITHOUT THE SOLE WRITTEN PERMISSION OF MB DESIGN.

4

macbridebeetham interiordesign 1103 Argyle St 16 Argyle Court Mount Florida G3 9ND Gjmacbride@gmail.com Mail@melbabeetham.com Melba: 0969386829 Graeme: 07821346504

5

6

7

8

STAGE

SCALE

CONSTRUCTION

1/50

DATE

DRAWING NO

25/09/10

0P1/PL/004

SHEET TITLE

DRAWN BY

SHEET NO

REFLECTED CEILING PLAN

GJM

REVISION

REVIEWED BY

A

MB

OPIUM 191 HOPE STREET GLASGOW

9

10

CEILING LEVEL CRITICAL DIMENSIONS CEILING LEVEL

HABITAT E27 PENDEL FITTING BLACK AND WHITE STRIPED CORD

G

E

MALE TOILETS

1715

D2

1250

625

D2

D2

D2

CH=2600mm AFF

350

D1

1800

P1 D3

HL

CH=2375mm AFF

CH=2800mm AFF

10/ MUST MAINTAIN ADEQUATE SUPPORT, INSULATION, WATERPROOFING, LIGHTING, SECURITY, ALARMS ETC FOR ALL ITEMS WHICH ARE TO REMAIN

HL

D1

725

2200

KITCHEN

250

D2

SERVERY

400

P1

SP

D1

BAR

D2

225

D2

P1

CH=2800mm AFF

E

D1

1210

150

P1

1050

D2

9/ TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND OR WORKMEN ON SITE. THE CONTRACTOR SHALL COMPLY WITH ALL RELELAVNT LAWS, REGULATIONS AND CODES PERTAINIGN TO SAFETY AND THE PREVENTION OF ACCIDENTS.

D2

400

D2

595

CH=2300mm AFF

D1

D2 D2

545

P1

D3

760

900

SP

P2

SP RESTAURANT

2940

1250

450

1005

80

CH=2300mm AFF D2

C

7/ PROTECT ALL EXISITNG PORTIONS OF THE EXISITNG BUILDING TO REMAIN DURING DEMOLITION/CONSTRUCTION, AND ALL ITEMS INCLUDING FURNITURE, FIXED OR LOOSE THE GENERAL CONTRCTOR IS RESPONSIBLE FOR ANY/ALL DAMAGES CAUSED BY HIMSLEF OR SUB-CONTRACTORS. CONTRACTOR TO LIAISE WITH CLIENT PRIOR TO COMMENCEMENT OF WORK.

960

1100

B

4/ CONTRACTOR SHALL NEVER SCALE OFF DRAWINGS. LOCATIONS FOR ALL PARTITIONS, WALLS, CEILINGS, ETC , WILL BE DETERMINED BY DIMENSIONS ON THE DRAWINGS. ANY SUCH DIMENSIONS MISSING FROM THE PLANS MUST BE BROUGHT TO THE ATTENTION OF THE DESIGNER IMMEDIATELY.

350

CH=2600mm AFF

D1

350

CH=2800mm AFF

510

CH=2300mm AFF

P1

A

ILLUMINATED EMERGENCY EXIT SIGN

H

4/18 11

G

12


1

2

3

4

5

6

7

8

9

10

11

12

A

A

D3

B

ENTRANCE

D2

D2

D2

D2

D2

D2

B

D2

REV A

REV A C

C

D2

DETAILED PARTIAL PLAN OF ENTRANCE AND FIXED SEATING Scale: 1:20

D

D 1500

150

3950

880

E

1750

1300

E

M

N F

455

200

1000

500

F

1270

1270

SECTIONAL ELEVATION THROUGH FIXED SEATING

SECTIONAL ELEVATION THROUGH FIXED SEATING

G

1270

Scale: 1:20

Scale: 1:20

G

CONSTRUCTION REVISION

NOTES H

A

ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED ON SITE AND ANY DISCREPENCIES SHOULD BE REFERRED TO MB DESIGN FOR THEIR DIRECTION. MB DESIGN WILL NOT BE HELD LIABLE WHEN FAILURE TO IMPLEMENT THIS REFERRAL OCCURS. WORK TO FIGURED DIMENSIONS ONLY. DO NOT SCALE OFF DRAWINGS.

1

2

PROPRIETARY TO BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURERS INSTRUCTIONS. SIZES OF ALL PROPRIETARY ITEMS SHALL BE CHECKED WITH THE MANUFACTURER. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO ENSURE THAT ALL MATERIALS AND WORKMANSHIP COMPLY

3

DATE

28/09/10

NOTES

REVISION TO ENTRANCE VESTIBULE WALL TO ACCOMMODATE FIRE EXTINGUISHGER AND EXTENSION TO NEW STUD WALL AT FIXED SEATING

WITH THE RELEVANT REGULATIONS AND THAT ALL HEALTH AND SAFETY REGULATIONS ARE IMPLEMENTED. THESE DRAWINGS ARE COPYRIGHT AND REMAIN THE PROPERTY OF MB DESIGN. NO WORK NOR DESIGNS ON THESE DRAWINGS MAY BE REPRODUCED WITHOUT THE SOLE WRITTEN PERMISSION OF MB DESIGN.

4

macbridebeetham interiordesign 1103 Argyle St 16 Argyle Court Mount Florida G3 9ND Gjmacbride@gmail.com Mail@melbabeetham.com Melba: 0969386829 Graeme: 07821346504

5

6

7

8

PROJECT TITLE

STAGE

SCALE

OPIUM 191 HOPE STREET GLASGOW

CONSTRUCTION

1/50

DATE

DRAWING NO

28/09/10

OPI/DT/04

SHEET TITLE

DRAWN BY

SHEET NO

FIXED SEATING/ENTRANCE DETAIL

GJM

REVISION

REVIEWED BY

A

MB

9

10

H

15/18 11

12


18

490

18

490

18

490

18

490

18

455

18

490

18

SHELVING BELOW

UNDER COUNTER DISPLAY FRIDGE SLIDING DOORS

105

195

UNDER COUNTER DISPLAY FRIDGE SLIDING DOORS

600

405

115

K

1205

3030

1050

SPEED RAIL

GLASS WASHER

HANDWASH SINK/ STORAGE BELOW

ICE CHEST/DOUBLE COMPARTMENT CRUSHED/CUBED

SHELVING BELOW/ WORKTOP ABOVE

DOUBLE SINK UNIT/ STORAGE BELOW

470

350

COFFEE MACHINE / SHELVING BELOW

36

910

5

3030

BLACK MATTE PAINT FINISH OR BLACK LAMINATE

A

28/09/10

REVISION TO EQUIPMENT LOCATION

macbridebeetham interiordesign 1103 Argyle St 16 Argyle Court Mount Florida G3 9ND Gjmacbride@gmail.com Mail@melbabeetham.com Melba: 0969386829 Graeme: 07821346504

28/09/10

A

28/09/10



OPIUM