axon-2014_j1db_en

Page 6

Telemetry systems

J-series 1-channel

AXON J1DB - technical data

- strain gauge with inductive power monitoring

Rotor Units J1DB-RD13 J1DB-RD13T J1DB-RD13H Signal conditioning Power supply Modulation Resolution Housing Dimensions (incl. Solder pads) Weight Sensitivity

Strain gauge (>100 ohms, full bridge) inductive or battery FSK (digital) 12 bit (pure data stream) Aluminum 45 x 19 x 7mm app. 10 grams 0,1 …. 500 mV/V adjustable by resistor Connections Solder Pads Carrier Frequency 13,6 MHz optionally 12,6 MHz, 14,6MHz, 15,6 MHz Operating Temperature J1DB-RD13 -40°C …. +105°C Operating Temperature J1DB-RD13T -40°C …. +125°C Operating Temperature J1DB-RD13H -40°C …. +140°C Degree of protection IP67 with appropriate covering of the solder contacts J1DB-RF13 J1DB-RF13T J1DB-RF13H Signal conditioning Power supply Modulation Resolution Housing Dimensions (incl. Solder pads) Weight Sensitivity

Strain gauge (>100 ohms, full bridge) inductive or battery FSK (digital) 12 bit (pure data stream) without, flexible segmental design 107,5 x 15 x 4mm 5,1 grams 0,1 …. 500 mV/V adjustable by resistor Connections Solder Pads Carrier Frequency 13,6 MHz optionally 12,6 MHz, 14,6MHz, 15,6 MHz Operating Temperature J1DB-RF13 -40°C …. +105°C Operating Temperature J1DB-RF13T -40°C …. +125°C Operating Temperature J1DB-RF13H -40°C …. +140°C Degree of protection IP10, lacquered electronics, needs to be covered with e.g. silicone after installation

6