Page 1

Mars III Series

Convertible Redundancy On-Line UPS With its Power Factor 1, Mars III delivers the highest active power for the same kVA. The compact version with batteries included is the simplest choice for servers protection.

CRITICAL LOADS

INDUSTRY

HEALTHCARE

GOVERMENT

EDUCATION

Highlights: • Rack/Tower Convertible Design • Power Factor 1.0 • Patent Backup Runtime Estimation • Flexibible Battery Configuration • Easy Parallel Installation • Frequency Converter Operation Mode • Smart ECO Mode • Generator Compatible Mode • Full-time Digital Signal Processor Control • LCD Panel • Power Range and Runtime Scalability


Mars III Series Specifications MODEL

AB-MSIII4500RT

AB-MSIII6000RT

Voltage Range

Input

Frequency Range

45~70Hz (Auto Sensing)

Phase

Single Phase with Ground

Input Current Distortion Capacity

3% 0.99 @ Full Load 4500VA/4500W

6000VA/6000W

Output Voltage Output Voltage Distortion

1% @ 100% Linear load /

±1Hz or ±3Hz (Selectable) 3:1

Output Waveform Line Mode

Pure Sine Wave 93%

94%

High Efficiency Mode

98% Sealed Lead Acid Maintenance

Battery Type

20 Batteries 12V/9Ah

Battery Number

4 hours

Recharge Time (to 90%)

2-mode operation, 2.1A(max.), Temperature compensation(Option)

Charger Status On LED + LCD Readings On LCD Self-Diagnostics

Alarm

Audible and Visual

Protection

Full Protection

Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, and Transferring with interruption & UPS Fault Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage, Inner Temperature, Backup time estimation

Upon Power-on, Manual control by panel & communication, self routine check Line Failure / Battery Low / Transfer to Bypass / System Fault Overload, Over temperature, Short circuit, Charging failure, Battery Disconencted Normal/ ECO/ CVCF (Constant Voltage/Constant Frequency)

Multi-Mode

Function

Yes

DC start

up to 4 units

Parallel capacity

3+1

Parallel redundancy

Physical

Enviromental

RT Model

Dimensions (WxHxD,mm/inch) Net Weight(kg)

Operation Temperature Operation Humidity Altitude Noise Level

7U 440x308x680mm

9U 440x396x680mm

115.5 Kgs

142.5Kgs

0~40C / 32~104F 20%~95%RH (Without condensing) 1000m/3280ft without Derating 55dBA @ 1 Meter

Standard

Interface

Protocol supported Slot Option Compatible Platforms

Standards and Certifications

3% @ 100% non-linear load with PF=0.9 ±1%

Output Voltage Regulation

Crest Factor

Display

10000VA/10000W

1

Frequency Range

Battery

8000VA/8000W

104-120VAC / 208-240VAC

Output Power Factor

Efficiency

AB-MSIII10000RT

110Vac~280Vac

Input Power Factor

Output

AB-MSIII8000RT

USB, EPO, Expansion J-Bus, Modbus, SEC RS232, RS485, Dry Contact Relay, SNMP/WEB Card Microsoft Windows series, Linux, Mac, etc.

Safety EMC

60dBA @ 1 Meter

EN62040-1, UL1778 EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A

Marks Marks

EN62040-3 CE, UL, cUL, FCC, Energy Star

*Specifications subject to change without notice.

Ablerex LATAM

3785 N.W. 82nd ave, Suite 406. Doral, Florida USA

www.ablerexlatam.com