Fire system replacement upgrade only new ADU´s in fully sprinkler building. -Install of new IFP - 75 fire alarm control unit (FACU) Install of new of AES 7707 Wireless Communicator near panel Install of new manual Pull Station near panel Install of new smoke detector, one near panel & thru-out floor area Install of new hornstrobe sounders in common area Install of new low frequency sounders in every ADU unit Install of monitor modules to wireless communicator, waterfloor tamper switch to be monitored.


SAN FRANCISCO FIRE PROTECTION, INC.

YOUR PROJECT


SAN FRANCISCO FIRE PROTECTION, INC.

WHO ARE WE?


Fernando Pèrez Design and marketing manager

1-800-291-0262 fperez@allsescorp.com

Elisa Villacorta

Plans Agent 1-800-291-0262 kev.allsescorp@gmail.com

Diego Saravia California Manager

1-800-291-0262 dsaravia@allsescorp.com

Julio MejĂ­a

Project Manager 1-800-291-0262 jmejia@allsescorp.com


HOW IT LOOKS

plans


SAN FRANCISCO FIRE PROTECTION, INC.


AES & FACP WIRING DIAGRAM

AES 7788F

J4 NO NC C

2.2K 立

Dry Contact For Supervisory

2.2K 立

PRODUCT: 7788F AND 7744F A 12 volt, 7.5 Amp Hour standby battery is required to meet UL Standard 864 edition 9 listing requirements.

G

Dry Contact For Troubles

Z2 Z3

2.2K 立

Z4 Z5

Program Zones 1-4 as F with R and Zones 5-8 as B

G Z6 Z7 G Z8

DACT Tip / T Ring / R T1

2.2K 立

R1

Program to dial 5555

NO NC C

Line 1

Tip / T Line 2

The 7.5 amp hour battery will provide enough standby power for the 7788 or 7744 subscriber unit to operate under normal conditions for a minimum of 24 hours.

J4

4 hours of operation requires -- 1 amp 8 hours of operation requires -- 2 amps 12 hours of operation requires -- 3 amps 16 hours of operation requires -- 4 amps 20 hours of operation requires -- 5 amps 24 hours of operation requires -- 6 amps 60 hours of operation requires -- 18 amps

Program Phone Line NO

AP Tip

Ring / R

AP Ring

T1

RJ31 TELCO Tip

R1

Program to Disable Line 2 supervision

AES STAND ALONE BATTERY CALCULATION Device/Model

The normal current load for a 7788F and 7744F, under normal operating conditions is 250ma/hr.

RJ31 TELCO Ring

QTY

AES 7707

1

AP Tip 1 AP Ring 1

Alarm Current (Amps)

Total Current

1.200

1.200

24 4.800 Total Alarm/Transmit Current (Amps)

1.200

Required Alarm Time Capacity (Amp-Hour)

+

4.800

Total Capacity (Amp-Hours)

Required Alarm Capacity (Amp-Hours)

Required Standby Capacity (Amp- Hours)

4 hours of operation requires -- 1.2 amp4 8 hours of operation requires -- 2.4 amp 12 hours of operation requires -- 3.6 amp 16 hours of operation requires -- 4.8 amp 20 hours of operation requires -- 6 amp 24 hours of operation requires -- 7.2 amp 60 hours of operation requires -- 18 amp

MOUNTING HEIGHTS

0.200

0.200 0.200

Input Required Standby Time

The normal current load for a 7788F and 7744F with supplemental units 7067 or 7794, under normal operating conditions is 300ma/hr.

AES 7794 IntelliPro Fire

Total Standby

Total Standby Load

RJ31 CPE Tip RJ31 CPE Ring

Stand by Current (Amps)

1.2

+

6.000

1.200

Safety Factor

x

1.2

Total A/H Required

=

7.200

** 1-12 VDC 10 AMP HOUR BATTERY PROVIDED**

HOW IT LOOKS

Z1 G

Dry Contact For Troubles

AES STANDBY BATTERY CALCULATIONS J2

REVISIONS:

Value determined by FACP's input spec.

REV.

**Input that will Activate Local Trouble Annunciation

ALARM MONITORING COMPANY AMERICOM CENTRAL STATION INC. FILE-VOL NO.S6031-1 CCN-UUFX (202653-001) LASTING CATEGORY-PROTECTIVE SIGNALING SERVICES CENTRAL STATION INSTALLER'S NAME & ADDRESS SAN FRANCISCO FIRE PROTECTION UL FILE# S6272-1 1355 FAIRFAX AVENUE SAN FRANCISCO, CA 94124

CONTRACTOR'S PHONE NUMBER TEL.: (415) 282-4288

CONTRACTOR'S C10 LICENSE NUMBER CA STATE C10 LICENSE NO. 806216

CONDUIT (TYP.)

FACU

MIM

4 SQ. BACK BOX

EOL

AC-CONNECTION

SLC

A

RISER DIAGRAM

B

B A

BLK

ROOF

GRN WHT

4TH FLOOR

FACU

3RD FLOOR

FACU

2ND FLOOR NC#1 #14/2

INDOOR 72" MAX. 66" AVERAGE @ EYE LEVEL

INNER WALL

LF

HS

LF

LF

EOL LF

AES 7707 WIRELESS FIRE ALARM COMMUNICATOR

PULL

ALARM

42"-48" @ CENTER ABOVE FINISHED FLR. TO MONITORING STATION

12V 10AH BATTERY

S

D02 SMOKE DETECTOR

S

D01 SMOKE DETECTOR NEAR TO PANEL

6

ANTENNA

PULL STATION

FIRE

FLOOR

LF

P

IFP-75 CONTROL UNIT

M04 MANUAL PULL NEAR TO PANEL

plans

110 VAC DEDICATED CIRCUIT

IDP-MIN

12V 7AH 12V 7AH BATTERY BATTERY

SLC Loop #16/2

EXP: 4/30/2020

RN OF CA L I FO

CONTRACTORS STAMP

- SLC-

AIM

CONTROL PANEL

LICENSE NO. 806216

TE

M03 IDP-MINIMON-MONITOR MODULE

TS

M02 TAMPER SWITCH

FS

M01 WATER FLOW

1ST FLOOR

1262 UNION ST, SAN FRANCISCO, CA.

TO CONTACT

F I R E

80" INCHES A.F.F. OR 6" INCHES BELOW CEILING WHICHEVER IS LOWER

TA

S

ADA STROBE OR ANY NOTIFICATION APPLIANCES

E LECTRICAL

D

+

TRACTOR CON

EOL

IA

FACU

TO CONTACT

ENGINEERED BY SAN FRANCISCO FIRE PROTECTION

TYPICAL DEVICE WIRING

REGI STERE

WIRING-AIM, MIM

ADDRESS:

CEILING DETECTOR

INSTALLATION TYPE

NEW INSTALLATION

TENANT IMPROVEMENT

SYSTEM SERVICE/REPLACEMENT

CALCULATION, RISER AND DETAILS

DATE DRAWN

9/25/2019

SCALE

DRAWN BY

N.T.S.

CG

INITIAL ISSUE DATE -

LATEST ISSUE DATE

FA 4 OF 4

-


SAN FRANCISCO FIRE PROTECTION, INC.

DN UP

CLOSET

CLOSET

DINING ROOM

LAUNDRY

DINING ROOM

LAUNDRY

KITCHEN

KITCHEN

LIVING ROOM

LIVING ROOM

BEDROOM

BEDROOM

UNIT 1

CLOSET

NOT WORK

BATHROOM

ENTRY

UP

NOT WORK

BATHROOM

ENTRY

UP

BATHROOM

BATHROOM

DN

CLOSET

LIVING ROOM LAUNDRY

BEDROOM

LAUNDRY

KITCHEN

DINING ROOM

UP

DINING ROOM

DN

UNIT 4

LIVING ROOM

KITCHEN

UP

ENTRY

CLOSET

UNIT 2

CLOSET

DN

HALL BEDROOM

ENTRY

HALL

CLOSET

BEDROOM

BEDROOM

UNIT 3

CLOSET

HALL

DN

3 THIRD FLOOR

2 SECOND FLOOR

REVISIONS:

BEDROOM

REV.

DN UP

BEDROOM

ALARM MONITORING COMPANY AMERICOM CENTRAL STATION INC. FILE-VOL NO.S6031-1 CCN-UUFX (202653-001) LASTING CATEGORY-PROTECTIVE SIGNALING SERVICES CENTRAL STATION INSTALLER'S NAME & ADDRESS SAN FRANCISCO FIRE PROTECTION UL FILE# S6272-1 1355 FAIRFAX AVENUE SAN FRANCISCO, CA 94124 CONTRACTOR'S PHONE NUMBER TEL.: (415) 282-4288 CONTRACTOR'S C10 LICENSE NUMBER CA STATE C10 LICENSE NO. 806216 ENGINEERED BY SAN FRANCISCO FIRE PROTECTION E LECTRICAL

LICENSE NO. 806216

DINING ROOM

LAUNDRY

KITCHEN

EXP: 4/30/2020

E OF L I FOR CA

ST

AT

CLOSET

NI A

REGI STERE

BEDROOM

TRACTOR CON

D

DN

CONTRACTORS STAMP LIVING ROOM

NOT WORK

BATHROOM

NOT WORK

ENTRY

BATHROOM

DN HALL

BEDROOM

ENTRY

UNIT 6

CLOSET

LIVING ROOM

CLOSET

BEDROOM

1262 UNION ST, SAN FRANCISCO, CA.

UNIT 5

CLOSET

ADDRESS:

BEDROOM

LAUNDRY

UP DN

KITCHEN

DINING ROOM

INSTALLATION TYPE NEW INSTALLATION TENANT IMPROVEMENT SYSTEM SERVICE/REPLACEMENT

4 FOURTH FLOOR

5 ROOF

FLOOR PLANS

DATE DRAWN 9/25/2019 SCALE

DRAWN BY

N.T.S.

CG

INITIAL ISSUE DATE -

LATEST ISSUE DATE -

FA 3 OF 4


BATH ROOM

KITCHEN/DINING

REV.

STUDIO

BATHROOM

ALARM MONITORING COMPANY AMERICOM CENTRAL STATION INC. FILE-VOL NO.S6031-1 CCN-UUFX (202653-001) LASTING CATEGORY-PROTECTIVE SIGNALING SERVICES CENTRAL STATION

OFFICE

KITCHENETTE

INSTALLER'S NAME & ADDRESS SAN FRANCISCO FIRE PROTECTION UL FILE# S6272-1 1355 FAIRFAX AVENUE SAN FRANCISCO, CA 94124

CLOSET

ADU #2

HOW IT LOOKS REVISIONS:

UP

NC#1-5

NC#1 #14/2

LF

N

CONTRACTOR'S PHONE NUMBER TEL.: (415) 282-4288

LF

N

NC#1 #14/2

N

N

S

D02

CLOSET

ADU #1

ENGINEERED BY SAN FRANCISCO FIRE PROTECTION

UP

NC#1-4

LF

REGI STERE

NC#1-6

LF

N

BATH ROOM TRASH ROOM LIVING ROOM N

UP

M01

P M04

N

S

FS

D01

M02 N

TS

N

LOBBY

BICYCLE PARKING

M03

AES 7707 FACU

DN

DN

BEDROOM

AT

LICENSE NO. 806216

EXP: 4/30/2020

E OF L I FOR CA

ST

CLOSET

NC#1 #14/2

BEDROOM

E LECTRICAL

D

TRACTOR CON

ADU #3

N

KITCHENETTE

NI A

NC#1-2

NC#1-3

HS

CONTRACTOR'S C10 LICENSE NUMBER CA STATE C10 LICENSE NO. 806216

CORRIDOR

N

CONTRACTORS STAMP

1262 UNION ST, SAN FRANCISCO, CA.

LF

ADDRESS:

NC#1-1

INSTALLATION TYPE

NEW INSTALLATION

1 FIRST FLOOR

plans

TENANT IMPROVEMENT

SYSTEM SERVICE/REPLACEMENT

FLOOR PLANS AND DEVICE LOCATIONS

DATE DRAWN

9/25/2019

SCALE

DRAWN BY

N.T.S. INITIAL ISSUE DATE -

CG LATEST ISSUE DATE

FA 2 OF 4

-


SAN FRANCISCO FIRE PROTECTION, INC.

OCCUPANCIES..................................R-2 & S

2)

NO. OF STORIES...............................4 (8 UNITS)

3)

CONSTRUCTION TYPE.................... V

4)

BUILDING TYPE.................................SPRINKLERS AREA IN SQUARE FEET.................. 7,200

6)

SIGNALING LINE CIRCUIT: CLASS "B"

7)

NOTIFICATION CIRCUIT: CLASS "B"

SYSTEM TYPE:

AES 7707

DESCRIPTION

SUPPLIER

FIRE ALARM CONTROL

AES 7707

C.S.F.M. LIST.

SILENT KNIGHT

7165-0559:0503

WIRELESS FIRE ALARM COMMUNICATOR

AES

7300-1516:0501 7125-1653:0188

1

HS

P2R

WALL MOUNT HORN/STROBE

SYSTEM SENSOR

LF

HW-LF

LOW FREQUENCY SOUNDER

SYSTEM SENSOR

7135-1653:0516

2

S

IDP-PHOTO

SMOKE DETECTOR

SILENT KNIGHT

7272-0559:0149

P

IDP-PULL-SA

MANUAL PULL STATION

SILENT KNIGHT

7150-0559:0157

IDP-MINIMON

MONITOR MODULE

1

SMOKE DETECTOR, MANUAL PULL STATION, 2016 NFPA 72 CENTRAL SYSTEM MONITORING

MONITORING: ALARM MONITORING COMPANY AMERICOM CENTRAL STATION INC.

1

MODEL IFP-75

5

AUTOMATIC AND MANUAL FIRE ALARM W/MONITORING SERVICE INVOLVED:

FILE-VOL NO.S6031-1 CCN-UUFX

FACU

UL # S6031-1

IDP-MIN

1

FS

IDP-MIN

MONITOR MODULE

SILENT KNIGHT

7300-0559:0155

TS

IDP-MIN

MONITOR MODULE

SILENT KNIGHT

7300-0559:0155

1

SYSTEM SENSOR

LISTING CATEGORY-PROTECTIVE

LEGEND:

SIGNALING SERVICES CENTRAL STATION ALL SIGNALS WILL BE SENT TO THE APPROVED

N - NEW DEVICE AT NEW LOCATION

SUPERVISORY STATION.

REV.

1-415-824-5400

U.L. CERTIFICATION: THIS INSTALLATION IS IN COMPLIANCE WITH U.L. STANDARDS AND CERTIFIED BY

ALARM MONITORING COMPANY AMERICOM CENTRAL STATION INC. FILE-VOL NO.S6031-1 CCN-UUFX (202653-001) LASTING CATEGORY-PROTECTIVE SIGNALING SERVICES CENTRAL STATION

U.M. SAN FRANCISCO FIRE PROTECTION

U.L. # S6272-1

9/25/2019

Panel IFP-75 BATTERY CALCULATION Alarm

Total

Alarm

Stby

(5 min)

Amp-Hr

0.3100

3.960

0.026

3.986

IFP-75

CONTROL BOARD/DACT

0.1650

AES 7707

RADIO COMMUNICATOR

0.0130

0.2000

0.312

0.017

0.329

IPD-PHOTO

SMOKE DETECTOR

0.0003

0.0065

0.014

0.001

0.015

1

IDP-PULL

PULL STATION

0.0006

0.0055

0.014

0.000

0.015

3

IDP-MINIMON

MONITOR MODULE

0.0004

0.0055

0.029

0.001

0.030

1

NC# 1 TOTAL

NC# 1 TOTAL LOAD/6 DEVICES

0.0000

0.8660

0.000

0.072

0.072

Total:

Amp-Hr Total:

4.447

20% Reserve: (4.447 x 0.2)

0.889

(2)7 Amp-Hour

Min. Total Draw w/Reserve:

5.337

-INSTALL OF NEW MANUAL PULL STATION NEAR PANEL MANUAL PULL STATION WILL BE INSTALLED BETWEEN 42" TO 48" @ CENTER ABOVE FINISHED FLOOR -INSTALL OF NEW SMOKE DETECTORS, ONE NEAR PANEL & THRU-OUT FLOOR AREA SENSORS WILL BE INSTALLED @ 6" BELOW CEILING WHICHEVER IS LOWER -INSTALL OF NEW HORNSTROBE SOUNDERS IN COMMON AREA -INSTALL OF NEW LOW FREQUENCY SOUNDERS IN EVERY ADU UNIT NOTIFICATION APPLIANCES WILL BE INSTALLED BETWEEN 80" AND 96" ABOVE FINISHED FLOOR. PER CFC 2016 SEC 907.5.2.1.1 AUDIBLE NOTIFICATION APPLIANCES SHALL APPROVE AN AVERAGE SOUND PRESSURE LEVEL OF 75 dBA -INSTALL OF MONITOR MODULES TO WIRELESS COMMUNICATOR, WATERFLOW, TAMPER SWITCH TO BE MONITORED 2016 NFPA 72 CENTRAL SYSTEM MONITORING. IN COMPLIANCE WITH SFFC SEC 1103.7.6.1 VOLUNTARY FIRE ALARM REPLACEMENT SYSTEM TO COMPLY WITH CALIFORNIA STATE FIRE MARSHAL INFORMATION BULLETIN (09/04/2008) AND CALIFORNIA STATE FIRE MARSHAL CODE INTERPRETATION #12-001 (07/23/2012). THIS WORK DOES NOT COMPLY WITH ANY BUILDING CODES, FIRE CODES OR NFPA 72

SHEET 1- DRAWING LEGEND, GENERAL NOTES, CALCULATIONS, SEQUENCE OF OPERATION AND DRAWING INDEX. SHEET 2- FLOOR PLANS WITH DEVICE LOCATIONS

E

F

G

H

I 01 03

04 Fire alarm system low battery

04

05 Open circuit

05

06 Ground fault

06

07 Notification appliance circuit short 08 Water flow switch

07

CIRCUIT # 1

QUANTITY

TA

0.138A CURRENT DRAW

1

5

EXP: 4/30/2020

R OF CA L I FO

CONTRACTORS STAMP

09 C

D

E

F

G

H

I

VOLTAGE DROP CALCULATIONS

0.176A CURRENT DRAW

LICENSE NO. 806216

TE

10 B

LOW FREQ. SOUNDER

LF

ELECTRICAL

D

08

A

IFP-75 FACU

DRAWING INDEX

D

02

HS

FIRE SYSTEM REPLACEMENT UPGRADE ONLY NEW ADU'S IN FULLY SPRINKLER BUILDING -INSTALL OF NEW IFP-75 FIRE ALARM CONTROL UNIT (FACU) FACU WILL BE INSTALLED FROM 66" TO 72" MAXIMUM @ EYE LEVEL -INSTALL OF NEW AES 7707 WIRELESS COMMUNICATOR NEAR PANEL

C

03 Fire alarm AC power failure

HORN/ STROBE

SCOPE OF WORK:

B

01 Manual fire alarm box-All 02 Area Smoke detector

Sprinkler control valve 09 10 AES Radio Failure

4.447

Supplied Battery:

A

ENGINEERED BY SAN FRANCISCO FIRE PROTECTION

S

1 2

INPUT/OUTPUT MATRIX

CONTRACTOR'S C10 LICENSE NUMBER CA STATE C10 LICENSE NO. 806216

ADDRESS:

24

Supv

Amp-Hr Current Req.*

Ac

Description

CONTRACTOR'S PHONE NUMBER TEL.: (415) 282-4288

TRACTOR CON

1

Model

Ac

Per NFPA 72 24 Hour Standby + 5 Minutes Alarm

INSTALLER'S NAME & ADDRESS SAN FRANCISCO FIRE PROTECTION UL FILE# S6272-1 1355 FAIRFAX AVENUE SAN FRANCISCO, CA 94124

REGI STERE

1262 UNION ST, SAN FRANCISCO, CA.

No.

Notification

tiva te co mm tiva on te ala au Ac dib rm tiva le sig te ala na co Ac rm l in mm tiva sig dic on te na ato tro co la Su ra mm ub tF pe tF le AC rvis on AC sig U tro ory U na Tra ub l in ala ns le dic mit rm sig ato sig na su Tra ra p l n ns at erv al tF mit FA at iso AC FA CU fire Tra ry U CU sig ns ala na mit rm l to tro Ac sig su ub tiva na pe le l to te rvis sig no su na ory tific pe l to sta rvis ati su on tio in p g n erv ap sta plia isin tio nc gs n es tati thru on -ou t th eb ldg .

Control Unit Annunciation

NI A

UL

7300-0559:0155

1

CIRCUIT DEVICE SUB TOTAL

6 TOTAL

CALCULATIONS TOTAL CIRCUIT LOAD 0.866

CIRCUIT 14 AWG WIRE DISTANCE RESISTANCE (IN FEET) (PER FOOT) X

185

X

0.00252

VOLTS DROPPED =

0.4037

VOLTAGE DROP %

SUPPLY VOLTAGE รท

1262 UNION ST, SAN FRANCISCO, CA.

5)

1

REVISIONS:

QTY. SYM.

PROJECT ANALYSIS: 1)

20.4

=

1.9791

END OF LINE VOLTAGE 18.4209

1.9791

INSTALLATION TYPE NEW INSTALLATION

SHEET 3- FLOOR PLANS

TENANT IMPROVEMENT

SHEET 4- CALCULATION, RISER AND DETAILS

SYSTEM SERVICE/REPLACEMENT DRAWING LEGEND, GENERAL NOTES, CALCULATIONS, SEQUENCE OF OPERATION AND DRAWING INDEX.

DATE DRAWN 9/25/2019 SCALE

DRAWN BY

N.T.S.

CG

INITIAL ISSUE DATE -

LATEST ISSUE DATE -

FA 1 OF 4


Horn strobe Super loud sound, the alarm volume over or equal to 110dB ,Make sure that the message can be head for all the people.

Pull Station This fire alarm pull station model BG-12L uses a standard Allen key for opening and resetting, so you don't have to worry about losing a special key that will never be found when needed.

WIRELESS FIRE ALARM COMMUNICATOR Uses LTE network for highspeed, reliable and low-cost communications to an IP receiver.

Low frequency The SpectrAlert Advance P2RH-LF is a red, two-wire, 24 volt, low frequency sounder strobe with selectable high-candela strobe settings of 135, 150, 177 and 185 cd for wall or ceiling installation

IFP - 75 IFP-75 has a single line circuit (SLC) loop for connecting addressable detectors, which can support 75 IDP/SK sensors and 75 IDP/SK modules or 75 SD devices per loop.

IDP monitor module Silent Knight IDP Monitoring Module acts as an interface to contact devices, such as waterflow switches and pull stations.


SAN FRANCISCO FIRE PROTECTION, INC.

devices WE´LL WORK WITH


schedule


SAN FRANCISCO FIRE PROTECTION, INC.


SAN FRANCISCO FIRE PROTECTION, INC.


Job Card


SAN FRANCISCO FIRE PROTECTION, INC.


SAN FRANCISCO FIRE PROTECTION, INC.

Profile for Fernando Perez

Propuesta 1  

Propuesta 1  

Advertisement