Page 1

AIR S A M P L I N G

V O L . 5


PUMPS

4

CALIBRATORS & ROTAMETERS

14

IAQ, BIOAEROSOL & MICROBIOLOGICAL SAMPLERS

16

IMPACTORS & CYCLONES

19

CALIBRATION ACCESSORIES & SURFACE SAMPLERS

21

CASSETTES

22

TUBES & TUBE HOLDERS

27

PERSONAL & AREA PUMP ACCESSORIES

28

GAS SAMPLING BAGS

30

See inside back cover for ordering information.


WHY CHOOSE ERE?


AIR SAMPLING

Gilian® BDX-II Abatement Personal Air Sampling Pump The Gilian® BDX-II is designed specifically for asbestos and lead abatement applications when constant flow is not required. The built-in rotameter displays flow rates over the entire flow range of 0.5 - 3.0 LPM and an electronic flow control adjustment enables parts to last longer so maintenance is minimized. Sealed flow adjustment and on/off switch protects the Gilian® BDX-II from moisture, dust and fibers. Features • Flow rate: 500 - 3,000 cc/min (total) • Built-in rotameter • Will operate 10 hours at 2.0 LPM with inlet pressure of 20" • Rechargeable NiMH battery pack • Certifications: Not Intrinsic Safe

Available To Rent Part Number

Description

Flow Rate (Total)

Power Source

GIL-801863-171-1201

Gilian® BDX-II Starter Kit

500 - 3,000 cc/min

120V

GIL-100421

Gilian BDX-II 5-Pump Kit With 5-Unit Chargers

500 - 3,000 cc/min

120V

GIL-100423

Gilian® BDX-II 5-Pump Kit With 5-Station Charger

500 - 3,000 cc/min

120V

GIL-800511

17.5" x 13" x 7" Carrying Case

-

-

Inf Z

®

5-Pump Kit Includes • (5) Gilian® BDX-II pumps • (5) Pieces of 36" tubing • (5) Clip assemblies • (5) Reversible screwdrivers • (5) Single unit chargers (GIL-100421) or a 5-station charger (GIL-100423) • (5) User manuals • Heavy-duty foam lined carrying case

Differences Between Basic, Clock, & Programmable Models

ne

• The Basic model is straight-forward and easy to use. • Clock models provide an elapsed-time clock display. • Programmable models enable a timer which can start or stop the pump at preset time intervals or program a delayed start.

Gilian® LFS-113 Compact, Pocket-Sized, Personal Low Flow Air Sampling Pump The Gilian® LFS-113 is designed for flow rates between 1 - 350 cc/min, perfect for very low flow application sampling with sorbent tubes. Offers two user selectable sampling modes; the constant flow control mode holds the flow within ±5% of the set flow while the constant pressure control mode (multi-flow) allows multiple samples to be taken simultaneously through the use of a multi-flow manifold. No other pocket-sized pump matches the wide flow range and high back-pressure capability of the Gilian® LFS-113. Features • Flow rate: 1 - 350 cc/min (total) • Dual mode automatic constant flow or constant pressure control • Flow fault indicator light • Clock model/elapsed time display • Battery check LED • Rechargeable NiMH battery pack • Certifications: ATEX, CSA, C-US & UL Approvals - Intrinsic Safe

4

Starter Kit Includes • Gilian® BDX-II pump • 36" tubing • Clip assembly • Reversible screwdriver • Single unit charger • User manual

Starter Kit Includes • Gilian® LFS-113 pump • 36" tubing • Air boss kit • Single tube holder • Reversible screwdriver • Single unit charger • User manual

5-Pump Kit Includes • (5) Gilian® LFS-113 pumps • (5) Pieces of 36" tubing • (5) Air boss kits • (5) Single tube holders • (5) Reversible screwdrivers • 5-Unit charger • (5) User manuals

Part Number

Description

Model

Flow Rate

Power Source

GIL-910-0301-01

Gilian® LFS-113 D Starter Kit

Basic

1 - 350 cc/min

120V

GIL-910-0302-01

Gilian LFS-113 D 5-Pump Kit

Basic

1 - 350 cc/min

120V

GIL-910-0303-01

Gilian® LFS-113 DC Starter Kit

Clock

1 - 350 cc/min

120V

GIL-910-0304-01

Gilian LFS-113 DC 5-Pump Kit

Clock

1 - 350 cc/min

120V

GIL-800400

18" x 13" x 7" Carrying Case

-

-

-

®

®

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Gilian® GilAir-3 & Gilian® GilAir-5 Personal Air Sampling Pumps The Gilian® GilAir-3 and Gilian® GilAir-5 pumps are suitable not only for conventional pull-through sampling media but also for bag sampling and other pressure applications. These 3 and 5 LPM air sampling pumps have automatic constant flow compensation, assuring sampling is maintained within ±5% of the initial set point, even with varying back-pressures from flow restrictions or buildup of material on the filter. Features • Flow rate: Gilian® GilAir-3: 1- 3,000 cc/min (total) Gilian® GilAir-5: 1- 5,000 cc/min (total) • Optional low flow modules • Flow fault & test indicators • External filter housing • Rechargeable NiMH battery pack • Certifications: UL - Intrinsic Safe

Part Number

Description

Model

Flow Rate (Total)

Power Source

GIL-800485-171-1201

Gilian® GilAir-3 R Starter Kit

Basic

1 - 3,000 cc/min

120V

GIL-800485-171-1205

Gilian GilAir-3 R 5-Pump Kit With 5-Unit Charger

Basic

1 - 3,000 cc/min

120V

GIL-800508-171-1201

Gilian® GilAir-3 RC Starter Kit

Clock

1 - 3,000 cc/min

120V

GIL-800508-171-1205

Gilian® GilAir-3 RC 5-Pump Kit With 5-Unit Charger

Clock

1 - 3,000 cc/min

120V

GIL-800510-171-1201

Gilian GilAir-3 RP Starter Kit

Programmable

1 - 3,000 cc/min

120V

GIL- 800510-171-1205

Gilian® GilAir-3 RP 5-Pump Kit With 5-Unit Charger

Programmable

1 - 3,000 cc/min

120V

GIL-800883-171-1201

Gilian GilAir-5 R Starter Kit

Basic

1 - 5,000 cc/min

120V

GIL-800883-171-1205

Gilian® GilAir-5 R 5-Pump Kit With 5-Unit Charger

Basic

1 - 5,000 cc/min

120V

GIL-800885-171-1201

Gilian® GilAir-5 RC Starter Kit

Clock

1 - 5,000 cc/min

120V

GIL- 800885-171-1205

Gilian GilAir-5 RC 5-Pump Kit With 5-Unit Charger

Clock

1 - 5,000 cc/min

120V

GIL-800884-171-1201

Gilian® GilAir-5 RP Starter Kit

Programmable

1 - 5,000 cc/min

120V

GIL-800884-171-1205

Gilian GilAir-5 RP 5-Pump Kit With 5-Unit Charger

Programmable

1 - 5,000 cc/min

120V

GIL-800511

17.5" x 13" x 7" Carrying Case

-

-

-

®

®

®

®

®

Starter Kit Includes • Gilian® GilAir-3 or Gilian® GilAir-5 pump • 36" tubing • Air boss kit • Filter cassette holder • Reversible screwdriver • Single unit charger • User manual 5-Pump Kit Includes • (5) Gilian® GilAir-3 or Gilian® GilAir-5 pumps • (5) Pieces of 36" tubing • (5) Air boss kit • (5) Filter cassette holder • (5) Reversible screwdriver • 5-Unit charger • (5) User manual • Carrying case

Need Help Deciding On A Pump? Answer the following questions to help narrow it down. 1. What flow rate do you require? 2. What sampling method are you using? • Bags (need an exhaust port) • Tubes • Cassettes 3. What gas (or gases) are you sampling for?

4. Will you need a calibrator? 5. Extra bells and whistles? • Data logging • Bluetooth • Programmable • Etc.

AIR SAMPLING

5


AIR SAMPLING

Gilian® GilAir® Plus Personal Air Sampling Pump The Gilian® GilAir® Plus is the world’s most capable air sampling pump now with 3 new technologies such as Motion Detection, BluetoothTM Connectivity and the CONNECT Mobile App! Three models to choose from; the basic model, the datalogging pump (DL) model and the standard temperature and pressure (STP) model. Features • Flow rate: 1 - 5,100 cc/min (total) • Flow modes: constant flow or high and low flow constant pressure • QuadModeSM air sampling technology • Selectable automatic fault recovery • SmartCalSM automatic calibration • High back pressure capability • Temperature & pressure compensation • Rechargeable NiMH battery pack • Certifications: EN 1232 Compliant, ISO 13137:2013 Compliant, Intrinsic Safe, US/Canada NRTL (FM), ATEX, CE Applicable Directives

Starter Kit Includes • Gilian® GilAir® Plus pump • Tubing • Filter cassette holder • Charcoal tube holder • 2 mm hex key • Charging dock with power adapter • User manual • Single unit carrying case • Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software

Available To Rent

5-Pump Kit Includes • (5) Gilian® GilAir® Plus pumps • (5) Pieces of tubing • (5) Filter cassette holders • (5) Charcoal tube holders • (5) 2 mm hex keys • Charging dock with power adapter • 5-Unit power station • (5) ser manuals • 5-Unit carrying case • Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software

Part Number

Description

Model

Flow Rate (Total)

Power Source

GIL-910-0901-US-R

Gilian® GilAir® Plus Starter Kit

Basic

1 - 5,100 cc/min

120V

GIL-910-0904-US-R

Gilian GilAir Plus 5-Pump Kit With 5-Unit Power Station

Basic

1 - 5,100 cc/min

120V

GIL-910-0902-US-R

Gilian® GilAir® Plus Starter Kit

Data Logging

1 - 5,100 cc/min

120V

GIL-910-0905-US-R

Gilian GilAir Plus 5-Pump Kit With 5-Unit Power Station

Data Logging

1 - 5,100 cc/min

120V

GIL-910-0910-US-R

Gilian® GilAir® Plus Starter Kit

BT Data Logging

1 - 5,100 cc/min

120V

GIL-910-0912-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

BT Data Logging

1 - 5,100 cc/min

120V

GIL-910-0903-US-R

Gilian GilAir Plus Starter Kit

STP

1 - 5,100 cc/min

120V

GIL-910-0906-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

STP

1 - 5,100 cc/min

120V

GIL-910-0911-US-R

Gilian GilAir Plus Starter Kit

BT STP

1 - 5,100 cc/min

120V

GIL-910-0913-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

BT STP

1 - 5,100 cc/min

120V

®

®

®

®

®

®

®

®

*3-Pump kits also available

Inf Z 6

Differences Between Basic, Data Logging, & STP Models

ne

• The basic model is straight forward and easy to use. • The data logging model provides additional advanced program functions and allows data logging and transferring of data to a PC. Also available with BluetoothTM option. • The STP model refers to standard temperature and pressure. These models correct the display flow rate and air volume to standard conditions of temperature and pressure. Also available with BluetoothTM option.

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Gilian® Power Series Personal Air Sampling Pumps The Gilian® Power Series is the industry leader in back pressure performance, reliability and ease-of-use. They also provide automatic constant flow controls and the Gilian® 5000 has an optional adapter module, which can handle lower flows under constant pressure control, such as required for multi-flow sorbent sampling. Features • Flow rate: Gilian® 800i: 200 - 800 cc/min (total) Gilian® 5000: 20 - 5,000 cc/min (total) Gilian® 10i: 4,000 - 10,000 cc/min (total) Gilian® 12: 4,000 - 12,000 cc/min (total) • Highest back-pressure capability • Programmable • Live flow display • Rechargeable NiMH battery pack • Certifications: Gilian® 800i, Gilian® 5000 & Gilian® 10i: Intrinsic Safe, US/Canada NRTL (FM), ATEX & CE Applicable Gilian® 12: Not Instrisic Safe

AIR SAMPLING

High Efficiency Air Sampling Pumps

Starter Kit Includes Model

Gilian® 800i

Gilian® 5000

Gilian® 10i

Gilian® 12

Includes

• Gilian® 800i pump • 1/4" x 36" tubing • Single unit charger • User manual

• Gilian® 5000 pump • Filter cassette holder • Single unit charger • User manual

• Gilian® 10i pump • 3/8" x 36" tubing • Single unit charger • User manual

• Gilian® 12 pump • 3/8" x 36" tubing • Single unit charger • User manual

Model

Gilian® 800i

Gilian® 5000

Gilian® 10i

Gilian® 12

Includes

• (5) Gilian 800i pumps • (5) Pieces of 1/4" x 36" tubing • 5-Unit power station • (5) User manuals • Carrying case

• (5) Gilian 5000 pumps • (5) Filter cassette holders • 5-Unit power station • (5) User manuals • Carrying case

• (5) Gilian 10i pumps • (5) Pieces of 3/8" x 36" tubing • 5-Unit power station • (5) User manuals • Carrying case

• (5) Gilian® 12 pumps • (5) Pieces of 3/8" x 36" tubing • 5-Unit power station • (5) User manuals • Carrying case

5-Pump Kit Includes ®

®

®

Part Number

Description

Flow Rate (Total)

Power Source

GIL-910-1301-US

Gilian 800i Starter Kit With US Cord

200 - 800 cc/min

120V/230V

GIL-910-1305-US

Gilian® 800i 5-Pump Kit With US Cord

200 - 800 cc/min

120V/230V

GIL-910-0802-01

Gilian 5000 Starter Kit With US Cord

20 - 5,000 cc/min

120V/240V

GIL- 910-0801-01

Gilian® 5000 5-Pump Kit With US Cord

20 - 5,000 cc/min

120V/240V

GIL-910-1501-US

Gilian® 10i Starter Kit With US Cord

4,000 - 10,000 cc/min

120V/240V

GIL-910-1505-US

Gilian 10i 5-Pump Kit With US Cord

4,000 - 10,000 cc/min

120V/240V

GIL-910-1601-US

Gilian® 12 Starter Kit With US Cord

4,000 - 12,000 cc/min

120V/240V

GIL-910-1605-US

Gilian 12 5-Pump Kit With US Cord

4,000 - 12,000 cc/min

120V/240V

®

®

®

®

AIR SAMPLING

7


AIR SAMPLING

Gilian® AirCon-2 Portable High Volume Constant Flow Area Air Sampling Pump The Gilian® AirCon-2 sampler is a high volume unit with an extended flow range, designed for collecting particulate in a given plant area. It is ideal for asbestos background and clearance sampling following NIOSH, OSHA or EPA methodology and for ambient dust monitoring. Features • Flow rate: 2 - 30 LPM (total) • Fully programmable • Touchpad & LCD display • Instant fault function • Instant pressure check • Operates off either AC or battery power • Certifications: Not Instrisic Safe

Includes • Gilian® AirCon-2 pump • Hose • Sampling mast • Support tip • User manual

Part Number

Description

Flow Rate (Total)

Power Source

GIL-801012-100

Gilian® Aircon-2 DC Programmable Area Air Sampling Pump Only

2 - 30 LPM

120V

GIL-801000-2

Power Module 120V/230V/DC With 120V Cord

GIL-801001

Lead Acid Gel 4-Hour Battery Packv Requires Power Module (GIL-80100-2) To Charge (Note: May Stack (2) For 8-Hour Operation)

-

-

GIL-801171-1

22'' x 16'' x 8'' Wheeled Carrying Case For AirCon-2

-

-

Zefon® Escort® LC Personal Air Sampling Pump The Zefon® Escort® LC air sampling pump can be used with a variety of personal and area sampling devices to collect such airborne contaminants as asbestos fibers, toxic gases, vapors, particulates, fumes and mists. It can also be used to sample silica dust, coal dust and organic vapors. Features • Flow range: 0.5 - 3 LPM (total) • Inlet filter traps particulate matter • Separate LEDs indicate pump operation and low battery • Stainless steel-filled plastic case provides EMI/RFI protection • Rechargeable NiMH battery pack • Certifications: UL Approved as Intrinsically Safe for use in Hazardous Locations, Class I, Groups A, B, C, D; Class II, Groups E, F and G; Class III, Division I Locations Part Number

Description

Flow Rate (Total)

Power Source

ZE-711400

Zefon® Escort® LC With 120V Charger

0.5 - 3 LPM

120V

ZE-P5-ESLC-5-1-0-0

Zefon® Escort® LC 5-Pump Kit With 5-Unit Charger

0.5 - 3 LPM

120/240V

ZE-811741

Protective Leather Holster Case

-

-

Includes • Escort® LC pump • Sampling line • 120V charger • User manual 5-Pump Kit Includes • (5) Escort® LC pumps • (5) Sampling lines • 5-Unit charger • User manual • Carrying case

Personal Pump Accessories

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft CY-8860-4335

Sorbent Tube Holder APB-109030

Metal Luer Adapter ZE-459743

Please refer to page 28 for more information.

8

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

37mm Cassette Tubing Adapters ZE-ZA0005

36'' Sampling Line with Tube Clip ZE-456226

Universal Cassette or Cyclone Holder ZE-ZA0061


AIR SAMPLING

Zefon® Escort ELF® Personal Air Sampling Pump The Zefon® Escort ELF® air sampling pump features a state of the art electronic laminar flow sensor to provide a constant flow control with ± 2.5% regulation of flow rate from 1 - 3 LPM with automatic compensation for changes in battery voltage, temperature, altitude, and sample load. An internal secondary standard calibrates the pump continuously and needs to be checked against a primary standard only once per month (or every 200 hours for coal mine dust sampling). Features • Flow rate: 0.5 - 3 LPM (total) • Patented electronic laminar flow control • Inlet filter traps moisture and particular matter • Stainless steel-filled plastic case provides EMI/RFI protection • Rated IP65 for resistance to water and dust ingress • Flow fault indicator shows any sample inlet blockage • Run/Hold feature allows "time out" during sampling process • Elapsed time readout and low-battery warning •Low flow and dual tube sampling available with Zefon® Gemini Twin-Port Sampler • Rechargeable NiMH battery pack • Certifications: NIOSH, MSHA, UL, ATEX specific models only

Includes • Zefon® Escort ELF® pump • Sampling line • 120V charger • User manual 5-Pump Kit Includes • (5) Zefon® Escort ELF® pumps • (5) Sampling lines • 5-Unit charger • User manual • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

ZE-805560

Zefon® Escort ELF® With 120V Charger & Sampling Line

0.5 - 3 LPM

120V

ZE-805563

Zefon Escort ELF With 5-Unit Charger & Sampling Line

0.5 - 3 LPM

120/240V

ZE-805559

Zefon® Escort ELF® With 120V Charger & Gemini® Twin Port Sampler

0.5 - 3 LPM

120V

ZE-711396

Zefon Escort ELF With 5-Unit Charger & Gemini Twin Port Sampler

0.5 - 3 LPM

120/240V

ZE-811741

Protective Leather Holster Case

-

-

®

®

®

®

®

* 240V also available

Buck Libra™ L-4 Abatement Personal Air Sampling Pump The Buck Libra™ L-4 is designed for sampling of asbestos, lead, and other airborne contaminates. This pump is used to draw air contaminants in through a sampling media such as 25 and 37 mm filter cassettes which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Low flows from 5 - 800 cc/min can be obtained using the optional Adjustable Universal Low Flow Holder.

Features • Flow rate: 0.8 - 4.0 LPM (total) 5 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) • High impact steel fiber filled Lexan case, antistatic and RFI shielded • "Auto-Restart" within one minute of a flow fault • High backpressure capable for 25 mm 0.45 μm asbestos filters • Built-in washable stainless steel 100 μm filter for economy of use • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: CE EMC Directive (EMCD) 89/336/EEC Part Number

Description

Flow Rate (Total)

Power Source

APB-926000

Buck Libra™ L-4 Starter Kit

0.8 - 4.0 LPM

120V

APB-942600

Buck Libra™ L-4 5-Pump Kit

0.8 - 4.0 LPM

120V

APB-109030

Adjustable Universal Low Flow Holder

-

-

Sarter Kit Includes • Buck Libra™ L-4 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Single pack NiMH battery • 120V charger • User manual

5-Pump Kit Includes • (5) Buck Libra™ L-4 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Single pack NiMH batteries • QuickFive™ charger 100-240V • (2) User manuals • Pelican carrying case model 1500

*230V also available

AIR SAMPLING

9


AIR SAMPLING

Buck Libra Plus™ Series Personal Air Sampling Pump The Buck Libra Plus™ is designed for sampling of asbestos, lead, and other airborne contaminates. These pumps display flow rate, elapsed time and accumulated volume of the sample. The Buck Libra Plus™ model LP-1 and LP-5 is used to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes whereas the Buck Libra Plus™ model LP-7, LP-12 and LP-20 can also use 47 mm filter cassettes; which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. Features • Flow rate: Buck Libra Plus™ LP-1: 100 - 600 cc/min (total) 5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109033) Buck Libra Plus™ LP-5: 0.8 - 5.0 LPM (total) 5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Libra Plus™ LP-7: 3.0 - 7.0 LPM (total) Buck Libra Plus™ LP-12: 3.0 - 12.0 LPM (total) 50 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Libra Plus™ LP-20: 5.0 - 20.0 LPM (total) • Displays: elapsed time, accumulated volume and flow rate • "Auto-Restart" within one minute of a flow fault • High backpressure capable for 25 mm 0.45 μm asbestos filters • Built-in washable stainless steel 100 μm filter for economy of use • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: CE EMC Directive (EMCD) 89/336/EEC Starter Kit Includes Model

Buck Libra Plus™ LP-1, LP-5 & LP-7

Buck Libra Plus™ LP-12

Buck Libra Plus™ LP-20

Includes

• Buck Libra Plus™ LP-1, LP-5 or LP-7 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-adjustable tube holder • Single pack NiMH battery • Standard 120V battery charger • User manual

• Buck Libra Plus™ LP-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-adjustable tube holder • Triple pack NiMH battery • Standard 120V battery charger • User manual

• Buck Libra Plus™ LP-20 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-adjustable tube holder • Triple pack NiMH battery • Standard 120V battery charger • User manual

5-Pump Kit Includes Model

Buck Libra Plus™ LP-1, LP-5 & LP-7

Buck Libra Plus™ LP-12

Buck Libra Plus™ LP-20

Includes

• (5) Buck Libra Plus™ LP-1, LP-5 or LP-7 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Non-adjustable tube holder • (5) Single pack NiMH batteries • Quick(5)™ charger 100-240V • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Libra Plus™ LP-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Non-adjustable tube holder • (5) Triple pack NiMH batteries • Quick(5)™ charger 100-240V • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Libra Plus™ LP-20 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Non-adjustable tube holder • (5) Triple pack NiMH batteries • Quick(5)™ charger 100-240V • (2) User manuals • Pelican carrying case model 1600

Part Number

Description

Flow Rate (Total)

Power Source

APB-906800

Buck Libra Plus™ LP-1 Starter Kit

100 - 600 cc/min

120V

APB-946500

Buck Libra Plus™ LP-1 5-Pump Kit

100 - 600 cc/min

120V

APB-906200

Buck Libra Plus™ LP-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-946200

Buck Libra Plus™ LP-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-906300

Buck Libra Plus™ LP-7 Starter Kit

3.0 - 7.0 LPM

120V

APB-942507

Buck Libra Plus™ LP-7 5-Pump Kit

3.0 - 7.0 LPM

120V

APB-906250

Buck Libra Plus™ LP-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-942512

Buck Libra Plus™ LP-12 5-Pump Kit

3.0 - 12.0 LPM

120V

APB-906700

Buck Libra Plus™ LP-20 Starter Kit

5.0 - 20.0 LPM

120V

APB-942520

Buck Libra Plus™ LP-20 5-Pump Kit

5.0 - 20.0 LPM

120V

APB-109033

Adjustable Universal Low Flow Holder

5 - 100 cc/min

-

APB-109030

Adjustable Universal Low Flow Holder

5 - 800 cc/min

-

*230V also available

10

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Buck Elite™ Personal Air Sampling Pump The Buck Elite™ series personal air sampling pump draws air contaminants in through a sampling media such as sorbent tubes, bubble impingers, long duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 0.6 LPM. Low flows from 5 - 99 cc/min can be obtained using the optional Low Flow Holder. Features • Flow rate: Buck Elite™-1: 0.005 - 0.6 LPM (total) 5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109033) Buck Elite™-5: 0.8 - 5.0 LPM (total) 5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Elite™-12: 3.0 -12.0 LPM (total) 50 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) • Capable for data logging and programmable for multiple "Start/ Stop" and duration sampling • Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case • Exclusive electronic circuit board for constant flow control • "Auto-Restart” within one minute of a flow fault • High backpressure compensation up to 36” of w.c. @ 300 cc/min • Flow compensation for filter plugging and battery voltage • Key pad lock system • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: CE EMC Directive (EMCD) 89/336/EEC

Starter Kit Includes Model

Buck Elite™-1

Buck Elite™-5

Buck Elite™-12

Includes

• Buck Elite™-1 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-Adjustable Low Flow Holder • Single pack NiMH battery • Standard 120V charger • User manual

• Buck Elite™-5 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Single pack NiMH battery • Standard 120V charger • User manual

• Buck Elite™-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Triple pack NiMH battery • Standard 120V charger • User manual

5-Pump Kit Includes Model

Buck Elite™-1

Buck Elite™-5

Buck Elite™-12

Includes

• (5) Buck Elite™-1 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Non-Adjustable Low Flow Holders • (5) Single pack NiMH batteries • Quick(5)™ 100-240V charger • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Elite™-5 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Single pack NiMH batteries • Quick(5)™ 100-240V charger • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Elite™-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Triple pack NiMH batteries • Quick(5)™ 100-240V charger • (2) User manuals • Pelican carrying case model 1600

Part Number

Description

Flow Rate (Total)

Power Source

APB-908100

Buck Elite™-1 Starter Kit

0.005 - 0.6 LPM

120V

APB-947300

Buck Elite™-1 5-Pump Kit

0.005 - 0.6 LPM

120V

APB-908000

Buck Elite™-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-947200

Buck Elite™-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-908300

Buck Elite™-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-948000

Buck Elite™-12 5-Pump Kit

3.0 - 12.0 LPM

120V

APB-109033

Adjustable Universal Low Flow Holder

5 - 100 cc/min

-

APB-109030

Adjustable Universal Low Flow Holder

5 - 800 cc/min

-

*230V also available

AIR SAMPLING

11


AIR SAMPLING

Buck Allin™ & Buck Allin™ Plus Intrinsically Safe Personal Low Flow Air Sampling Pump The Buck Allin™ & Buck Allin™ Plus series is a personal air sampler suitable for use in location where flammable gases, vapors, dust, fibers or flying’s are present. The purpose of this pump is to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes, bubble impingers, long-duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 5.0 LPM. Low flows from 5 - 799 cc/min can be obtained using the optional Low Flow Holder. Features • Flow rate: Buck Allin™-1 & Buck Allin™ Plus-1: 0.1 - 0.6 LPM (total) 5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Allin™-5 & Buck Allin™ Plus-5: 0.8 - 5.0 LPM (total) 5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Allin™-12 & Buck Allin™ Plus-12: 3.0 -12.0 LPM (total) 50 - 2999 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) • Buck Allin™ Plus models are capable of data logging and can be programmed for multiple "Start/ Stop" and duration sampling • Buck Allin™ Plus models allows temperature and barometric pressure compensation in STP mode • Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case • Exclusive electronic circuit board for constant flow control • "Auto-Restart" within one minute of a flow fault • High backpressure compensation up to 50" of w.c. @ 2 LPM • Flow compensation for filter plugging and battery voltage • Key pad lock system • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: UL 913 & CAN/CSA-C22.2 Intrinsically Safe, suitable for use in Class I, II, III, Div 1 Groups A-G, T3 Hazardous Locations Starter Kit Includes Model

Buck Allin™-1, Buck Allin™-5 & Buck Allin™-12

Buck Allin™ Plus-1, Buck Allin™ Plus-5 & Buck Allin™ Plus-12

Includes

• Buck Allin™-1, Buck Allin™-5 or Buck Allin™-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip

• Buck Allin™ Plus-1, Buck Allin™ Plus-5 or Buck Allin™ Plus-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip

• Single pack NiMH battery • Standard 120V charger • User manual

• Low Flow Holder • Single pack NiMH battery • Standard 120V charger • User manual

5-Pump Kit Includes Model

Buck Allin™-1, Buck Allin™-5 & Buck Allin™-12

Includes

• (5) Buck Allin™-1, Buck Allin™-5 or Buck Allin™-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Single pack NiMH batteries

Buck Allin™ Plus-1, Buck Allin™ Plus-5 & Buck Allin™ Plus-12 • Standard 110-240V smart charger kit • (2) User manuals • Carrying case

• (5) Single pack NiMH batteries • Standard 110-240V smart charger kit • (2) User manuals • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

APB-905000

Buck Allin™-1 Starter Kit

0.1 - 0.6 LPM

120V

APB-905050

Buck Allin™-1 5-Pump Kit

0.1 - 0.6 LPM

120V

APB-905200

Buck Allin™-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-905250

Buck Allin™-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-905400

Buck Allin™-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-905450

Buck Allin™-12 5-Pump Kit

3.0 -12.0 LPM

120V

APB-905100

Buck Allin™ Plus-1 Starter Kit

0.1 - 0.6 LPM

120V

APB-905150

Buck Allin™ Plus-1 5-Pump Kit

0.1 - 0.6 LPM

120V

APB-905300

Buck Allin™ Plus-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-905340

Buck Allin™ Plus-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-905500

Buck Allin™ Plus-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-905550

Buck Allin™ Plus-12 5-Pump Kit

3.0 - 12.0 LPM

120V

APB-109030

Adjustable Universal Low Flow Holder

5 - 800 cc/min

-

*230V also available

12

• (5) Buck Allin™ Plus-1, Buck Allin™ Plus-5 or Buck Allin™ Plus-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Low Flow Holder

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Zefon® High Volume Diaphragm Area Sampling Pump The Zefon® 23 stroke High Volume Diaphragm area sampling pump is an economical workhorses with a flow range of 3 - 14 LPM. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes. Includes • Zefon® High Volume Diaphragm pump with locking flow control valve • 10 ft tubing • Hose barb • On/Off switch

2-Pump Kit Includes • (2) Zefon® High Volume Diaphragm pumps with locking flow control valves • (2) pieces of 10 ft tubing • (2) Hose barbs • (2) On/Off switches • (2) Tripod stands • Heavy duty carrying case

Available To Rent

Part Number

Description

Flow Rate (Total)

Power Source

ZE-ZTHV01

Zefon® High Volume Diaphragm Pump

3 - 14 LPM

120V

ZE-ZTHV01-KIT

Zefon High Volume Diaphragm 2-Pump Kit

3 - 14 LPM

120V

ZE-195380

1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

ZE-195505

3 - 30 LPM Zefon® Non-Adjustable High Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

-

-

EMS-200550

Premium Telescopic Sampling Tripod Stand

-

-

ZE-ZTHV00-KCASE

Carrying Case For ZTHV01 Pumps (Holds (2) ZTHV01 Pumps, (2) Stands & Tubing)

-

-

®

*220V also available *Please refer to page 27 for area pump replacement parts and area pump accessories

New! Now with internal filter/muffler. No more glass muffler jars! Zefon® High Volume Rotary Vane Sampling Pump The Zefon® High Volume Rotary Vane pump is an economical alternative to the Gast brand Rotary Vane pumps with a flow range of 0 - 30 LPM. The workhorses are heavy duty with a 1/10 hp motor that can be used for almost all sampling applications. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes along with all viable impactors (ex: Andersen style impactor). Flow Rates PCM cassette: 3 - 15 LPM TEM cassette: 3 - 10 LPM Air-O-Cell® cassette: 15 LPM Viable Impactor: 28.3 LPM

Includes • Zefon® High Volume Rotary Vane pump with flow control valve • 2 1/4" I.D. tubing set • On/Off switch

Available To Rent

2-Pump Kit Includes • (2) Zefon® High Volume Rotary Vane pumps with flow control valves • (2) 2 1/4" I.D. tubing sets • (2) On/Off switches • (2) Tripod stands • Heavy duty carrying case

Part Number

Description

Flow Rate (Total)

Power Source

ZE-ZHV00

Zefon High Volume Rotary Vane Pump

0 - 30 LPM

120V

ZE- ZHV00-KIT

Zefon® High Volume Rotary Vane 2-Pump Kit

0 - 30 LPM

120V

ZE-116116

0 - 4 LPM Zefon® Non-Adjustable Low Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

ZE-195380

1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

ZE-195505

3 - 30 LPM Non-Adjustable High Flow Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

-

-

EMS-200550

Premium Telescopic Sampling Tripod Stand

-

-

ZE-ZHV00-KCASE

Carrying Case For ZHV00 Pumps (Holds (2) ZHV00 Pumps, (2) Stands & Tubing)

-

-

®

*220V also available *Please refer to page 29 for area pump replacement parts and area pump accessories

AIR SAMPLING

13


AIR SAMPLING

Zefon® Non-Adjustable Field Rotameters The Zefon® Field Rotameters are a low cost way to measure airflow in air sampling applications. They feature a durable acrylic housing with direct reading scales printed on them. Available in three different flow ranges covering a range of 0.2 through 30 LPM. Operation and maintenance are very simple; only a few common sense precautions must be observed to assure long, trouble-free service. Part Number

Description

Flow Rate (Total)

ZE-116116

Zefon Non-Adjustable Low Flow Field Rotameter

0 - 4 LPM

ZE-195380

Zefon® Non-Adjustable Medium Flow Field Rotameter

1 - 20 LPM

ZE-195505

Zefon® Non-Adjustable High Flow Field Rotameter

3 - 30 LPM

®

Features • Scales are large (average 4" length) and easy to read • The direct reading scales are hot stamped into the plastic and will not wear off • Mid-range calibration is established with a master flowmeter, providing an accuracy of ±3% Includes • Zefon® Non-Adjustable Field Rotameter (low, medium or high) • Tygon® tubing • Hose barb • Luer adapter

Available To Rent

Gilian® Go-CalTM Air Flow Calibrator The Gilian® Go-Cal™ Air Flow Calibrator is a portable, battery-operated calibrator with a precision air flow calibration between 0.01 - 20 LPM and accuracy within 2% of reading. Go-Cal™ displays air flow rate continuously allowing adjustments to pump flowrate in real-time. The Go-Cal™ displayed flowrate is compensated for temperature making it easier to produce consistent results at various calibration locations. Part Number

Description

Flow Rate (Total)

GIL-811-9916-01

Gilian® Go-CalTM Air Flow Calibrator Kit

0.01 - 20 LPM

Includes • Gilian® Go-CalTM Air Flow Calibrator • Tubing kit • Battery pack including (6) AA size alkaline batteries

• NIST traceable calibration certificate • User manual • Carrying case

Accurate, Reliable & Portable Primary Calibrators for Fast Calibration of Air Sampling Pumps! Defender 500 Series Defender 510 Volumetric Primary Flow Standard Defender 520 Enhanced Volumetric Primary Flow Standard Defender 530+ Standardized & Volumetric Primary Flow Standard Instantly calibrate your air samplers using Quick Start - there is no preparation involved, no messy soap bubble solutions. Alternatively, set your Defender to take hands-free, continuous measurements while you quickly set the flow rate on your pumps. Defender’s many user-selectable options makes customizing your calibrations easy, giving you exactly what you need in the format you prefer. All you have to do is choose between the 510, the 520 or the 530. Defender 510

Defender 520

Defender 530+

Model and Flow Ranges

BIO-200-510L: 5 - 500 cc/min BIO-200-510M: 50 - 5,000 cc/min BIO-200-510H: 300 - 30,000 cc/min

BIO-200-520L: 5 - 500 cc/min BIO-200-520M: 50 - 5,000 cc/min BIO-200-520H: 300 - 30,000 cc/min

BIO-200-530L: 5 - 500 cc/min BIO-200-530M: 50 - 5,000 cc/min BIO-200-530H: 300 - 30,000 cc/min

Volumetric Accuracy

1%

1%

1%

Standardized Accuracy User Selectable Measurement Units

14

Available To Rent

N/A

N/A

1.2%

Volumetric

ml/min, L/min, cc/min, cf/min

ml/min, L/min, cc/min, cf/min

ml/min, L/min, cc/min, cf/min

Standardized

N/A

N/A

smL/min, sL/min, scc/min, scf/min

Temperature

N/A

o

o

Pressure

C oF

C oF

N/A

mmHg, PSI, kPa

mmHg, PSI, kPa

Temperature and Pressure Sensor

No

Yes, in flow steam

Yes, in flow steam

Pressure Accuracy

N/A

3.5 mmHg (typical) 7.0 mm (max)

3.5 mmHg (typical) 7.0 mm (max)

Temperature Accuracy

N/A

0.8oC (typical) 1.3oC (max)

0.8oC (typical) 1.3oC (max)

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Three Flow Cells Available; Low, Standard & High Gilian® Gilibrator-2

The Gilian® Gilibrator-2 primary standard accuracy and performance validation for sampling pump airflows from 1 cc/min - 30 LPM. Features • Flow rate: Low Flow Cell: 1 - 250 cc/min (total) Standard Flow Cell: 20 - 6,000 cc/min (total) High Flow Cell: 2 - 30 LPM (total) • Consists of an electronic Gilibrator-2 base which is used with any of three sizes of flow cells • Cells use a twist-on bayonet design for quick and easy mounting to the base • These interchangeable cells generate perfect bubble films at the touch of a button • Infrared sensors read the bubble flow rate, which is then calculated and displayed • DC power source with internal battery pack • Certified for accuracy and traceable to NIST

Low, Standard & High Flow Cell Kit Includes • Control base • Flow cell (low, standard or high) • Tubing • Soap solution with dispenser • DC charger/AC power supply • Hard shell carry case

Deluxe Cell Kit Includes • Control base • Three interchangeable cells for low, standard and high flow rates • Tubing • Soap solution with dispenser • DC charger/AC power supply • Hard shell carry case

Part Number

Description

Flow Rate (Total)

GIL-800272

Gilian® Gilibrator-2 Low Flow Cell Kit With US Cord

1 - 250 cc/min

GIL-800271

Gilian® Gilibrator-2 Standard Flow Cell Kit With US Cord

20 - 6,000 cc/min

GIL-800270

Gilian Gilibrator-2 High Flow Cell Kit With US Cord

2 - 30 LPM

GIL-801804

Gilian® Gilibrator-2 Deluxe Cell Kit With All Three Cell Sizes & US Cord

1 - 250 cc/min, 20 - 6000 cc/min, 2 - 30 LPM

GIL-800450

Soap Solution Flow Cell For Gilian Gilibrator-2 Calibrator, 8 oz

-

®

®

Zefon® DigiCal™ Flow Calibrator The Zefon® DigiCal™ Flow Calibrator provides instantaneous calibration for instruments like the Zefon® Escort® LC pump or the secondary flow standard inside the Escort ELF® sampling pumps. Just press the plunger and the DigiCal™ calibrator does the work. Its unique flow cell replaces conventional bubble tubes and makes calibration easier. The DigiCal™ Calibrator achieves extreme accuracy by utilizing a computerized flow meter that provides instantaneous flow readouts on a digital display. Features • Flow rate: Zefon® DigiCal™ 5: 1 - 6,000 cc/min (total) Zefon® DigiCal™ 30: 0.1 - 30 LPM (total) • ± 0.5% accuracy • Microprocessor controlled to provide fast, accurate, repeatable measurements • Work at any altitude without correction • Instant readout of volumetric flow Includes • Zefon® DigiCal™ Flow Calibrator • Soap solution • Dispenser bottle • Charger • User manual

Part Number

Description

Flow Rate (total)

Power Source

ZE-655101

Zefon® DigiCal™ 5 Flow Calibrator

1 - 6,000 cc/min

110V

ZE-655130

Zefon DigiCal™ 30 Flow Calibrator

0.1 - 30 LPM

110V

ZE-655273

Soap Bubble Solution For Zefon® DigiCalTM Flow Calibrator, 8 oz

-

-

ZE-ZA0122

Pelican 1400 Carrying Case With Pick-N-Pluck Foam

-

-

®

AIR SAMPLING

15


AIR SAMPLING

Zefon® Bio-Pump® Plus The Zefon® Bio-Pump® Plus is the smallest, lightest and easiest to use portable, battery-powered IAQ pumps designed for exclusive use with Air-O-Cell® and Via-Cell® cassettes at a flow rate of 15 LPM. Features • Real time display showing actual run time • Programmable sample time (allows unattended operation) • "Sample Complete" audible & visual indicators • "Quick Sample" operation • Long Lasting NiMH battery provides approx. 8 hours of continuous run time or approx. 100 5-minute samples Model

Zefon® Bio-Pump® Plus Kit

Zefon® Bio-Pump® Plus Pro Kit

Zefon® Bio-Pump® Plus With TSI 4046 Calibrator Kit

Includes

• Zefon Bio-Pump Plus pump • Air flow indicator • (10) Air-O-Cell® cassettes • Charger • Warranty card • User manual • Carrying case

• Zefon Bio-Pump Plus pump • Air flow indicator • (10) Air-O-Cell® cassettes • (25) Bio-Tape™ slides • Bioisolation filter • Tripod stand • Charger • Warranty card • User manual • Carrying case

• Zefon® Bio-Pump® Plus pump • Air flow indicator • (10) Air-O-Cell® cassettes • TSI 4046 calibrator kit • Charger • Warranty card • User manual • Carrying case

®

®

®

®

Part Number

Description

Flow Rate (Total)

Sampling Media

Power Source

ZE-ZBP-205

Zefon® Bio-Pump® Plus With 110-230V Charger With North American Plug

15 LPM

(10) Air-O-Cell® Cassettes

120V

ZE-ZBP-PROKIT-PLUS

Zefon® Bio-Pump® Plus Pro Kit With Accessories

15 LPM

(10) Air-O-Cell® Cassettes (25) Bio-Tape™ Slides

120V

ZE-ZBP-205-CKIT

Zefon® Bio-Pump® Plus With TSI 4046 Calibrator Kit

15 LPM

(10) Air-O-Cell® Cassettes

120V

ZE-ZA0047

Bioisolation Filter For Zefon® Bio-Pump® Plus

-

-

-

ZE-ZA0043

Zefon Heavy Duty Tripod Stand For Zefon Bio-Pump Plus

-

-

-

®

®

* 230V also available

Zefon® Z-Lite™ IAQ Mold Sampling Starter Kits The Zefon® Z-Lite™ kits are an easy, convenient way to get everything you need to begin sampling for mold. It is a low maintenance-oscillating pump designed for use with all mold sampling cassettes and impactors.

Features • Flow rate: 3 - 33 LPM • Built-in adjustable flow meter/regulator • Rubber suction cup feet to prevent movement while in use

Model

Basic Kit

Deluxe Kit

Ultimate Kit

Includes

• Zefon Z-Lite™ pump with integrated combination flow meter/regulator valve • Tubing • (10) Air-O-Cell® • Bioisolation filter • Tripod stand • Basic set-up and user instructions • Toolbox style carrying case

• Zefon Z-Lite™ pump with integrated combination flow meter/regulator valve • Tubing • (20) Air-O-Cell® • (25) Bio-Tape™ slides • (10) Mold swabs • Bioisolation filter • Tripod stand • Basic set-up and user instructions • Toolbox style carrying case

• Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve • Tubing • (50) Air-O-Cell® • (50) Bio-Tape™ slides • (50) Mold swabs • (10) Inner wall attachments • Bioisolation filter • Tripod stand • Basic set-up and user instructions • Toolbox style carrying case

®

Part Number

Description

Flow Rate (Total)

Sampling Media

Power Source

ZE-Z-LITE-BMKIT

Zefon® Z-Lite™ IAQ Basic Mold Sampling Starter Kit

3 - 33 LPM

(10) Air-O-Cell® Cassettes

120V

ZE-Z-LITE-DMKIT

Zefon Z-Lite™ IAQ Deluxe Mold Sampling Starter Kit

3 - 33 LPM

®

(20) Air-O-Cell Cassettes (25) Bio-Tape™ Slides (10) Mold Swabs

120V

ZE-Z-LITE-UMKIT

Z-Lite™ IAQ Ultimate Mold Sampling Starter Kit

3 - 33 LPM

(50) Air-O-Cell® Cassettes (50) Bio-Tape™ Slides (50) Mold Swabs (10) Inner Wall Attachments

120V

®

* 230V also available

16

®

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


The Buck Bio-Series pumps are simple to operate and provides a selectable, continuous, and constant sample flowrate. Its quiet operation allows unobtrusive sampling in IAQ, medical, clean room, public, and residential building applications. The front key pad is organized into three functional key groups: Power (ONOFF), Timing (1, 2, 5, 10 minute samples) and Calibration (cal mode, increase flow, decrease flow). End of sample notice is provided by the lit LED "Complete" and three short beep.

Buck BioAire™ Bioaerosol Sampling Pump Features • Flow rate: 5 - 20 LPM • Small, lightweight, and compact • Accepts both Allergenco-D or Air-O-Cell® cassettes • NiCad batteries with 6 - 8 hours continuous run time at 15 LPM • Convenient timer for 1, 2, 5, 10 minute samples and continuous mode • End-of-cycle audible & visual • Easy keypad calibration without tools

AIR SAMPLING

Buck Bio-Series Pumps

Includes • Buck BioAire™ pump • Calibration rotameter assembly (APB-706100) • Standard smart 120V charger • User manual Part Number

Description

Flow Rate (Total)

Power Source

APB-706000

Buck BioAire™ Pump Model B520

5 - 20 LPM

120V

APB-108000

Durable Hard Plastic Carrying Case With Foam Insert

-

-

Buck BioSlide™ Biocontaminent Sampling Pump Features • Flow rate: 10 - 20 LPM • Small, lightweight, and compact • Accepts generic greased slides • NiCad batteries with 5 - 6 hours continuous run time at 15 LPM • End-of-cycle and battery level audible & visual • Tripod mount for area sampling Includes • Buck BioSlide™ pump • Calibration rotameter assembly (APB-706100) • Standard smart 120V charger • User manual Part Number

Description

Flow Rate (Total)

Power Source

APB-707000

Buck BioSlide™ Pump Model B1020

10 - 20 LPM

120V

APB-108000

Durable Hard Plastic Carrying Case With Foam Insert

-

-

Buck Bio-Culture™ Biocontaminent Sampling Pump Features • Flow rate: 30 - 120 LPM • Holds 90 mm agar petri dish • 380 holes - 1 mm diameter • Timing routine of 1, 2, 5 & 10 minutes • Tripod mount to allow 90o sampling • Sampling head is easily sterilized with gas torch or autoclave • Four times the flow rate of an Anderson sampler Includes • Buck Bio-Culture™ pump • Pencil torch • Tripod

• Standard smart 120V charger • User manual • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

APB-708000

Buck Bio-Culture™ Pump, Model B30120

30 - 120 LPM

120V

APB-708500

Calibration Head For Buck Bio-Culture™ Pump

-

-

AIR SAMPLING

17


AIR SAMPLING 18

MicroflowTM α Microbiological Air Sampler This instrument has been developed for airborne biological contaminants sampling in order to access the level of biocontamination in critical places (ex: clean rooms, operating rooms, pharmaceutical production plants, food and cosmetic industries, water purification plants, landfills, etc.) and in normal working life situations and not (air conditioning and ventilation controls). MicroflowTM α allows a wide range of airborne bio-contaminant sampling by impacting on agar plates (60 mm + 2 mm contact plate or 90 mm + 2 mm petri dish). Features • Flow rate: 30 - 60 - 90 - 100 - 120 LPM • Used with: 60 + 2 mm contact plate (MicroflowTM α 60) 90 + 2 mm petri dish (MicroflowTM α 90/C) Both with contact plate and petri dish (MicroflowTM α 60-90/C) • NiMH rechargeable battery, without memory effect • Silent microprocessor controlled fan to ensure maximum reliability on the sampled air volume • Compensation airflow system (in compensated models) • Low battery control and alarm • Prompts in 5 languages: English, French, German, Spanish, Italian & functions are "step-by-step" visualized • Delay start •Total volume of sampled air programmable from 1 up to 2000 L, with 1 L steps •Manual sampling for air volumes greater than 2000 L

• Sequential sampling also as required by ISPESL guidelines • Storing and displayed up to 99 samplings, with record of progressive n number, date, hour, sampling volume or time, flow rate, type of sampling (manual, sequential, programmable) • USB port to download data to a PC (optional) • Calibration control function (with optional calibration kit) • Remote switch with infra-red rays control • Vertical or horizontal sampling (90° and 180°) • Prepared for mounting on photographic tripod

Model

MicroflowTM α 60 Kit

MicroflowTM α 90/C Kit

MicroflowTM α 60-90/C Kit

Includes

• MicroflowTM α sampler • IR remote control • Pencil torch • Additional 60 mm aluminum sampling head • Base for sampler vertical positioning • Battery charger • Calibration report • Warranty card • User manual • Carrying case

• MicroflowTM α sampler • IR remote control • Pencil torch • Additional 90 mm aluminum sampling head • Base for sampler vertical positioning • Battery charger • Calibration report • Warranty card • User manual • Carrying case

• MicroflowTM α sampler • IR remote control • Pencil torch • 60 & 90 mm aluminum head assembly • Base for sampler vertical positioning • Battery charger • Calibration report • Warranty card • User manual • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

AQ-G.1004

MicroFlow™ α Kit 60 (For Use With Contact Plates 60 mm ± 2 mm)

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1004-SS

MicroFlow™ α Stainless Steel Kit 60 (For Use With Contact Plates 60 mm ± 2 mm)

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1015

MicroFlow™ α Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1015-SS

MicroFlow™ α Stainless Steel Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1027

MicroFlow™ α Kit 60-90/C (For Use With 60 mm ± 2 mm Contact Plate & With 90 mm ± 2 mm Petri Dishes), With Flow Compensation

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1120

Digital Calibration Kit For MicroFlow™ α Includes: Digital Differential Pressure Meter, Fitting Tubes & Conversion Table

-

-

AQ-G.1117-A

USB Interface For Data Download To PC Includes: Data Transmission & Data Management Software (In Compliance With UNICHIM No.1962) (Note: Data download requires a structural modification. In case of later purchase, MicroFlow™ α must be returned to Aquaria S.R.L. for software installation.)

-

-

AQ-A.2004

3 ft. Master Type Stand

-

-

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Zefon® A6 Impactor The Zefon® A6 Impactor sampler is an exact replica of the popular Andersen N-6 single stage impactor. The Zefon® A6 impactor is an aluminum device consisting of a top inlet "cone", a sampling head impactor stage which contains 400 precision drilled holes and a base section, which holds the agar media. The sampler is held together by three spring clamps and sealed with two o-ring gaskets. When air is drawn through the sampler, multiple jets of air direct any airborne particles toward the surface of the agar collection media surface where the particles are impacted and collected. The agar collection media is then sent to a laboratory for analysis. Features • Flow rate: 28.3 LPM (1 ACFM) • Particle size cut point: 0.65 μm • Sampler size: 4.25" diameter, 2.87" height, 1.23 lbs weight

• Material: aircraft grade aluminum • Uses 100 mm x 15 mm petri dishes • Certifications: meets NIOSH method 0800 & 0801 requirements

Part Number

Description

Power Source

ZE-Z-A6

Zefon A6 Impactor Only

120V

ZE-ZHV00-A6-KIT

Zefon® A6 Impactor Kit

120V

ZE-Z-A6-CAL

Adapter For "In-Line" Impactor Calibration

ZE-ZA0043

Zefon Heavy Duty Tripod Stand For Zefon A6 Impactor

Inf Z

®

®

®

-

Includes • Zefon® A6 Impactor • Pump flow meter • 1/4" I.D. tubing • Tripod stand • Carrying case

When Using A Zefon® A6 Impactor

ne

Accurate results when using a Zefon® A6 Impactor depend on proper measurement of flow through the impactor inlet. This can be best measured using a bubble or dry piston flow calibrator traceable to NIST standard (such as a Bios Defender or Gilian® Gilibrator) set up with the Zefon® A6 impactor "in-line". To your impactor "in-line", be sure to order the Z-A6-CAL adapter, which fits over the impactor inlet and allows tubing to be connected to it.

A static conductive replica of the 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Zefon® 10 mm Static Conductive Nylon Cyclone The Zefon® 10 mm Conductive Nylon Cyclone (Sensidyne "Dorr-Oliver" style) is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM. 10 mm Nylon Cyclone Efficiency Curve Comparison at 1.7 lpm

Collection Efficiency (%)

Features • Flow rate: ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm Other applications: 2 LPM with a nominal particle diameter of 3.5 μm • Conductive, eliminates any possible bias in sampling results from static charging • Lightweight design only 3.6 oz for the complete assembly including cassette and holder • Certifications: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust

Zefon 10 mm Heavy Duty Sensidyne TSI Zefon 10 mm Conductive

Particle Size (µ) Source: Internal Zefon performance tests with all 4 cyclones under identical conditions

Part Number

Description

ZE-ZA0080

Zefon® 10 mm Conductive Nylon Cyclone

ZE-ZA0081

Zefon® 10 mm Conductive Nylon Cyclone With Cassette/Cyclone Holder

ZE-ZA0063

Zefon® 1 Liter Cyclone Calibration Jar For Aluminum Cyclone & Zefon® Conductive Nylon Cyclone

ZE-ZA0085

Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones)

ZE-ZA0061

Zefon® Universal Cassette/Cyclone Holder Only

ZE-ZA0082

Replacement Grit Pots, 25/Pack

The cyclone must be used in conjuction with a cassette/cyclone holder. Compatible with both the Zefon® cassette/cyclone holder ZE-ZA0061 or the SKC holder SK-225-1.

AIR SAMPLING

19


AIR SAMPLING

10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Sampler For Respirable Dust & Silica The "Dorr-Oliver" 10 mm Nylon Cyclone is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM. Features • Flow rate: ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm Other applications: 2 LPM with a nominal particle diameter of 3.5 μm • Certification: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust Part Number

Description

GIL-800061

10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

GIL-7013376

Cyclone Calibration Jar For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone & Inhalable Dust Sampler Head

GIL-200159

Replacement Cyclone Grit Pot For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

GIL-801124

Replacement Cylcone Vortex Finder Accessory For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

Inf Z

Cyclone Calibration Jar

ne

When ordering a traditional Sensisyne "Dorr-Oliver" cyclone sampler, be sure to also order a Cyclone Calibration Jar GIL-7013376. Since a Sensidyne "Dorr-Oliver" cyclone has only a single hose connection, this jar allows proper placement of the cyclone filter between the sampling pump and the calibrator device.

A replica of the SKC Aluminum Cyclone Zefon® Aluminum Cyclone For Respirable Dust The Zefon® Respirable Dust Aluminum Cyclone is used in conjunction with 25 mm or 37 mm 3-piece filter cassettes to separate and remove larger particles from the respirable particles collected on the cassette’s filter. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm at 2.5 LPM flowrate. A cyclone holder and 25 mm or 37 mm 3-piece filter cassette are required for use of the Zefon® Aluminum Cyclone. Features • Aluminum construction is static conductive, eliminating interference • Lightweight design only 1.1 oz • Fully interchangeable with SKC Aluminum Cyclone • Certification: specified in NIOSH method 0600 for respirable particulates & NIOSH 7500 for silica, crystalline

20

Part Number

Description

ZE-ZA0060

Zefon® 37 mm Aluminum Cyclone For Respirable Dust

ZE-ZA0075

Zefon® 25 mm Aluminum Cyclone For Respirable Dust

ZE-ZA0062

Zefon® 37 mm Aluminum Cyclone For Respirable Dust With Holder

ZE-ZA0076

Zefon® 25 mm Aluminum Cyclone For Respirable Dust With Holder

ZE-ZA0063

Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone

ZE-ZA0085

Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones

ZE-ZA0061

Zefon® Universal Cassette/Cyclone Holder Only

ZE-ZA0066

Replacement Grit Pots For Aluminum Cyclone, 25/Pack

ZE-ZA0067

Replacement O-Rings For Aluminum Cyclone, 5/Pack

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Shown with cassette installed in holder


AIR SAMPLING

Zefon® Aluminum Cyclone Calibration Adapter A chamber specifically designed to fit over the Zefon® Aluminum Cyclone and connect 1/4" I.D. tubing for flow calibration. This provides the best calibration option by taking an actual measurement as close to the cyclone inlet as possible. Chamber fits both Zefon® brand and SKC brand 37 mm and 25 mm aluminum cyclones. Part Number

Description

ZE-ZA0011

Zefon® Aluminum Cyclone Calibration Adapter

Zefon® Calibration Jar The Zefon® Cyclone Calibration Jar is a container with all the proper fittings and connections to calibrate personal sampling pumps with the Zefon®, SKC, or Sensidyne "Dorr-Oliver" Cyclones and inhalable dust samplers. Part Number

Description

ZE-ZA0063

Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone

ZE-ZA0085

Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne “Dorr-Oliver” Nylon Cyclones

Zefon® Bio-Tape™ - Standardized Method For Surface Sampling Zefon® Bio-Tape™ provides a standardized surface sampling method used for the determination of possible microbial, bioaerosol, and inorganic dust contamination. It provides the ability to quickly take a sample and measure the relative degree of contamination. It is especially useful when sampling valuable or non-transportable materials and is very effective on smooth areas of concern. Features • Provides sample consistency • Individually serialized for traceability • Prevents cross contamination • Eliminates problems of placing tape in a zip bag, or broken glass slides • Samples may be archived by the laboratory for later review • Requires less laboratory prep time

Part Number

Description

ZE-BT0025

Zefon®Bio-Tape™ Slides, 25/Box

ZE-BT0050

Zefon®Bio-Tape™ Slides, 50/Box

ZE-BT0500

Zefon®Bio-Tape™ Slides, 500/Box

* Limited shelf life

Zefon®Sterile Surface Swabs Zefon® Sterile Surface Swabs are an easy way to sample suspect areas for mold contamination. Simply swab the suspect area and submit to a laboratory where the sample will be cultured and the type of mold identified. Each swab comes in an easy to use container for sampling, transport and storage. Part Number

Description

ZE-ZA0020

Mold Swab Kit

ZE-ZA0023

Mold Swabs Only, 50/Box

Includes • (10) Swabs • (10) Sterile 10 cm x 5 cm templates

* Limited shelf life

3M™ LeadCheck™ Swabs 3M™ LeadCheck™ Swabs provide an easy solution for lead detection. Easy to use, disposable 3M LeadCheck swabs will work on any surface, instantly turning bright pink when lead is present. 3M LeadCheck swabs are odorless, disposable, and non-staining. Part Number

Description

LC8S10C

3M™ LeadCheck™ Swabs, 8/Pack

Features • Detects lead on most surfaces within 30 seconds • Simple to use: just crush, shake and swab. RED MEANS LEAD™! • Disposable, no-mess swabs are easy, clean and contained • Test confirmation card to verify results in every kit AIR SAMPLING

21


AIR SAMPLING

Zefon® Preloaded Air Sampling Filter Cassettes Zefon® offers a complete line of air sampling cassettes manufactured to meet all applicable NIOSH, OSHA, and EPA standards. All cassette housings are manufactured in-house from polystyrene or polypropylene and are available in two or three piece configurations. Cassettes are individually assembled and preloaded under stringent quality assurance standards with only the finest quality membrane and support pads. Features • Fully assembled, preloaded and ready to use • Leak free construction eliminates sample loss • Configurations available to conform with most NIOSH standards that require filter cassettes • Wide selection of filter membrane types • Available with Zefon® Solu-Sert™ or Gravi-Sert™ filter capsules installed • Sterile models available for fluid contamination sampling and microbiological analysis • Ultra Pure PTFE models available for pharmaceutical compound sampling • Custom configurations available

PVC Preloaded Filter Cassettes Part Number

Diameter

Pore Size

Housing Style

Notes

Quantity

ZE-525PVC

25 mm

5.0 μm

2-Piece, Styrene

50/Box

ZE-5M52P

25 mm

5.0 μm

2-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-5P52P

25 mm

5.0 μm

2-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

ZE-535PVC

25 mm

5.0 μm

3-Piece, Styrene

50/Box

ZE-5M53P

25 mm

5.0 μm

3-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-5P53P

25 mm

5.0 μm

3-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

ZE-725PVC

37 mm

5.0 μm

2-Piece, Styrene

50/Box

ZE-7M52P

37 mm

5.0 μm

2-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-7P52P

37 mm

5.0 μm

2-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

ZE-735PVC

37 mm

5.0 μm

3-Piece, Styrene

50/Box

ZE-7M53P

37 mm

5.0 μm

3-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-7P53P

37 mm

5.0 μm

3-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

*Limited shelf life

MCE Preloaded Filter Cassettes Part Number

Diameter

Pore Size

Housing Style

Notes

Quantity

ZE-528MCE

25 mm

0.8 μm

2-Piece, Styrene

50/Box

ZE-538MCE

25 mm

0.8 μm

3-Piece, Styrene

50/Box

ZE-7345MCE

37 mm

0.45 μm

3-Piece, Styrene

50/Box

ZE-PS7345MCE

37 mm

0.45 μm

3-Piece, Styrene

Sterile

50/Box

ZE-734MCECF

37 mm

0.45 μm

3-Piece, Conductive

50/Box

ZE-7345MCECF

37 mm

0.45 μm + 5.0 μm

3-Piece, Conductive

50/Box

ZE-7445MCE-C

37 mm

0.45 μm

4-Piece, Styrene

Filter Placed Between Spacer Rings

50/Box

ZE-7445MCECF-C

37 mm

0.45 μm

4-Piece, Conductive

Filter Placed Between Spacer Rings

50/Box

ZE-728MCE

37 mm

0.8 μm

2-Piece, Styrene

50/Box

ZE-729MCE

37 mm

0.8 μm

2-Piece, Styrene, Banded

50/Box

ZE-7M92M

37 mm

0.8 μm

2-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-738MCE

37 mm

0.8 μm

3-Piece, Styrene

50/Box

ZE-PS738MCE

37 mm

0.8 μm

3-Piece, Styrene

Sterile

50/Box

ZE-738MCECF

37 mm

0.8 μm

3-Piece, Conductive

50/Box

ZE-739MCE

37 mm

0.8 μm

3-Piece, Styrene, Banded

50/Box

ZE-7M93M

37 mm

0.8 μm

3-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-7M93M-SB

37 mm

0.8 μm

3-Piece, Styrene, Banded

Match-Weighed Filters With Security Band

50/Box

*Limited shelf life

22

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® pre-weighed cassettes eliminate the inconvenience of pre-weighing filters by providing the filter weight on each cassette prior to sampling. Features • Each cassette is labeled with weight and serial number • Use of pure homopolymer PVC filters provides excellent weight stability • PVC filters specially designed with no silica and low ash properties Part Number

Diameter

Pore Size

Housing Style

Weight Tolerance

Quantity

ZE-5P52P

25 mm

5.0 μm

2-Piece Styrene

15 μg

50/Box

ZE-5P52P-GS

25 mm

5.0 μm Gravi-Sert™

2-Piece Styrene

15 μg

50/Box

ZE-5P53P

25 mm

5.0 μm

3-Piece Styrene

15 μg

50/Box

ZE-7P52P

37 mm

5.0 μm

2-Piece Styrene

15 μg

50/Box

ZE-7P53P

37 mm

5.0 μm

3-Piece Styrene

15 μg

50/Box

AIR SAMPLING

Gravimetric Pre-Weighed Cassettes

*Limited shelf life

Using A Pre-Weighed Cassette

Inf Z

ne

Using A Match-Weight Cassette

Environmental conditions can have a significant effect on filter weight readings. When using Zefon® pre-weighed cassettes, it is important that the post sample weighing is performed under the same environmental conditions used at the Zefon® factory. Those conditions are set at a temperature of 68°F and a relative humidity of 50%. Using Zefon® pre-weighed cassettes does not comply with OSHA directives which require both the "tare weight" and "secondary weight" to be performed on the same microbalance and environmental conditions. If complying with this directive is a concern, match-weighed cassettes are a good alternative way to save time and still comply with the directive.

The weight tolerance of match weighed filters references the maximum difference in weight from the test (top) filter and the control (bottom) filter. A stated tolerance of 50 μg means that the control filter may differ in weight no more than 50 μg from the test filter. This is important to know during post sample weighing as the weight tolerance of the 2 filters needs to be considered when calculating results.

Matched-Weighed Configuration

During manufacture, filters with matched weights (within the given tolerance) are inserted into the cassette in random order. Thus, it is possible for the control filter to weigh more than the test filter before sampling (within the given tolerance). If the control filter still weighs more after sampling, a sample likely was not collected. Please check your equipment for proper operation and pump flow.

Gravimetric Match-Weighed Cassettes Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® matchweighed cassettes eliminate the need of weighing filters before sampling by providing two filters which are matched in weight. The top filter collects particulate and the bottom filter serves as a control. After sampling, both filters are weighed and the difference in weight equals the amount of contaminate collected.

Features • Each cassette labeled with serial number • Color coded to indicate filter type • Preloaded - ready to use

Part Number

Filter

Diameter

Pore Size

Housing Style

Band Color

Weight Tolerance

Quantity

ZE-5M92M

MCE

25 mm

0.8 μm

2-Piece Styrene

Blue

50 μg

50/Box

ZE-5M93M

MCE

25 mm

0.8 μm

3-Piece Styrene

Blue

50 μg

50/Box

ZE-7M92M

MCE

37 mm

0.8 μm

2-Piece Styrene

Blue

50 μg

50/Box

ZE-7M92M-R-SB

MCE

37 mm

0.8 μm

2-Piece Styrene

Blue With Security Band

50 μg

50/Box

ZE-7M92M-TN

MCE

37 mm

0.8 μm

2-Piece Tenite, Meets Requirement Of ASTM D2276

None

50 μg

50/Box

ZE-7M93M

MCE

37 mm

0.8 μm

3-Piece Styrene

Blue

50 μg

50/Box

ZE-5M52P

PVC

25 mm

5.0 μm

2-Piece Styrene

Red

20 μg

50/Box

ZE-5M53P

PVC

25 mm

5.0 μm

3-Piece Styrene

Red

20 μg

50/Box

ZE-7M52P

PVC

37 mm

5.0 μm

2-Piece Styrene

Red

20 μg

50/Box

ZE-7M53P

PVC

37 mm

5.0 μm

3-Piece Styrene

Red

20 μg

50/Box

*Limited shelf life

AIR SAMPLING

23


AIR SAMPLING

Zefon® 25 mm MCE Preloaded Filter Asbestos Sampling Cassettes Zefon® and EMS offer PCM 25 mm conductive air sampling cassettes designed and manufactured to meet all applicable NIOSH, AHERA, OSHA, and EPA standards. The cassette housings are manufactured in-house from high quality polypropylene and are individually assembled and preloaded under stringent quality control standards. Features • 2" conductive extension cowl • 3-piece housing • Meets regulatory requirements • Each cassette comes with a unique serial number Part Number

Diameter

Pore Size

Housing Style

Notes

Quantity

ZE-Z008BA

25 mm

0.8 μm

3-Piece With 2" Conductive Cowl

Asbestos PCM, Banded

50/Box

EMS-900103

25 mm

0.8 μm

3-Piece With 2" Conductive Cowl

Asbestos PCM, Banded

50/Box

*Limited shelf life

Zefon® Air-O-Cell® Bioaerosol Cassettes The Zefon® Air-O-Cell® is a unique sampling cassette designed for the rapid collection of a wide range of both viable and non-viable aero-allergens including mold spores, pollen, insect parts, skin cells, fibers and inorganic particulate. These cassettes can be used with any standard off-the-shelf sampling pump capable of drawing 15 LPM open flow, including the Zefon® Bio-Pump® Plus, a convenient battery powered hand-held pump for ease of sampling. Air flow into cassette

Features • Industry proven & accepted • Independently validated • Laboratory preferred, easy to analyze • Proven results • No sample loss during shipping & handling • Pre-loaded, no slides to prepare

Alternaria

Pine pollen

Stachybotrys Skin cells

Dustmite

Exit orifice

Part Number

Description

Quantity

ZE-AOC050

Air-O-Cell® Air Sampling Cassettes

50/Box

ZE-AOCCAL

Air-O-Cell In-Line Calibration Adapter

Each

ZE-AOC-WS10

Air-O-Cell® Inner Wall Samplers

10/Pack

ZE-AOCWS10-KIT

Air-O-Cell® Inner Wall Sampler Kit

10/Pack & A Plunger Rod

®

*Limited shelf life

Inf Z 24

Inner Wall Sampling Attachments

ne

Zefon® Inner Wall Attachments are used in conjunction with Air-O-Cell®, MoldSNAP™, or Via-Cell® cassettes to non-destructively access microbial contamination in a wall cavity.equipment for proper operation and pump flow. To use, simply drill a 3/8" hole (preferably by hand), connect the tubing attachment to the cassette and insert the tube into the wall.

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Allergenco-D IAQ Air Sampling Cassettes The Allergenco-D disposable IAQ air sampling cassette was developed for the sampling and collection of aeroallergens and bioaerosols for quantitative analysis of mold spores, pollen, skin fragments, insects, combustion particles, toners, environmental dusts, construction dusts, and other airborne particulates. These cassettes employ a patented laminar flow venturi which provides higher readable collection efficiency than other IAQ cassettes as well as a more well defined impaction trace, helping to reduce analysis time. Features • Assembled under HEPA hoods • Laminar flow venturi allows for the most uniform slit deposit in the industry • Patented design • Higher collection efficiency than other IAQ slit impactor cassettes • Barcoded for easy tracking • Inner wall sampling attachments available • No luer adapters necessary - tubing fits directly onto cassette • Compatible with all portable IAQ pumps designed to fit competitors cassettes

Part Number

Description

Quantity

EMS-120515

Allergenco-D Air Sampling Cassettes

50/Box

EMS-120518

Allergenco-D Inner Wall Samplers

10/Pack

*Limited shelf life *Don’t forget to request your FREE Allergenco-D inner wall samplers with the purchase of a box of cassettes part # EMS-120518

The most uniform slit sample trace in the industry! Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes The Allergenco-D Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK). Features • Superior collection efficiency - aerodynamic diameter cutoff = D50 = ~1.7 μm • Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace • Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing • Generous area on the cassette label for field notes such as sample location, dates and time • Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive • Designed to stack cassettes for easy storage and use Part Number

Description

Quantity

EMS-120520

Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes

24/Box

*Limited shelf life

Cyclex-D Air Sampling Cassettes Utilizing a 360o impaction chamber, the Cyclex-D was pioneered to evenly and quantitatively collect aeroallergens. With a flow rate of 20 LPM the capture and actual collection efficiency of the Cyclex-D exceeded 50% at d50 = 1 μm compared to the industry norm of 2.5 μm. Part Number

Description

Quantity

EMS-120135

Cyclex-D Air Sampling Cassettes

50/Box

EMS-120138

Cyclex-D Inner Wall Samplers

10/Pack

*Limited shelf life *Don’t forget to request your FREE Cyclex-D inner wall samplers with the purchase of a box of cassettes part # EMS-120138-FREE

Need help choosing between the Zefon® High Volume Diaphragm Area Sampling Pump and the Zefon® High Volume Rotary Vane Sampling Pump? Don’t worry, ERE Inc.TM is here for you

1-888-287-3732 Please refer to page 11 for more information.

AIR SAMPLING

25


AIR SAMPLING

Micro5 MicroCell IAQ Air Sampling Cassettes Utilizing a 360o impaction chamber, the Micro5 was pioneered to evenly & quantitatively collect aeroallergens such as pollens, mold & fungal spores, fibers, danders, insect components and other air-borne contaminants. Features • Exceptionally uniform collection trace • Virtually 100% accurate for the entire fungal spore range • Designed to operate at a flow rate of 5 LPM to ensure optimal collection efficiency Part Number

Description

Quantity

EMS-120170

Micro5 Air Sampling Cassettes

50/Box

EMS-120138-M5

Micro5 Inner Wall Samplers

10/Pack

*Limited shelf life *Don’t forget to request your FREE Micro5 inner wall samplers with the purchase of a box of cassettes part # EMS-120138-M5

The most uniform slit sample trace in the industry! Micro5 Posi-Track Full Slide Indoor Air Quality Impactor Cassettes The Micro5 Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK).

Part Number

Description

EMS-120171

Micro5 Posi-Track Full Slide Indoor Air Quality 24/Box Impactor Cassettes

Quantity

*Limited shelf life

Features • Superior collection efficiency - aerodynamic diameter cutoff = D50 = ~1.7 μm • Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace • Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing • Generous area on the cassette label for field notes such as sample location, dates and time • Minimizes handling and mounting of sample traces for microscopic particle counting • Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive • Barcoded serial number (POSI-TRACK) allow for automated input of sample numbers into laboratory software (LIMS) and chain-of custody forms • Deposition of particles/spores onto the adhesive is very uniform due to the design of the laminar flow venturi within the spore trap • Designed to stack cassettes for easy storage and use

Zefon® Via-Cell® Bioaerosol Sampling Cassettes The Zefon® Via-Cell® bioaerosol sampling cassette is designed to collect both viable and non-viable bioaerosols, maintain viability of the viable mold spores and prevent growth during transport to the laboratory. Simply connect it to any pump calibrated to 15 LPM and run your sample. The key to the Via-Cell® is that the media used for collection maintains viability of spores and allows several analysis options.

One Sample, Multiple Analysis Options Culturable Sampling The Zefon® Via-Cell® sampler is the perfect tool for collecting viable organisms and culturing them on agar plates. Simply dilute the media in sterile water and transfer to a culture plate. PCR Analysis The Zefon® Via-Cell® utilizes a water soluble collection media which is ideal for PCR and other chemical types of analysis. Once the sample is diluted in water, it can be transferred most anywhere. Direct Microscopy Samples collected using the Zefon® Via-Cell® sampler may be "pre-screened" using direct microscopy methods, which allows the analyst to decide if additional analysis techniques are needed, which may include culturing or standard direct microscopy analysis. Part Number

Description

Quantity

ZE-VIA010

Via-Cell Air Sampling Cassettes

10/Box

®

*Limited shelf life

26

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Zefon® Gemini® Twin Port Sorbent Tube Sampler The Zefon® Gemini® Twin-Port Sorbent Tube Sampler can be used with the Zefon® Escort ELF®, or just about any other sampling pump able to pull a flow rate of 1.5 LPM at 25" of water backpressure. It offers increased flexibility and control in gathering samples through sorbent tubes. If air is being sampled for two or more contaminants, the Gemini can draw samples at independent flow rates through tubes containing different sorbents. In situations where a single contaminant is being sampled, sampling on two tubes of the same type can be done simultaneously at different flow rates. This type of sampling protects against breakthrough which occurs when a tube’s sampling capacity is exceeded because the concentration of a contaminant is higher than anticipated. Duplicate sampling at the same flow rate can also be done to achieve better results. Features • Valved mechanism allows flow control down to 0.001 LPM • Control the flow rate of each port independently • Includes tube covers to fit both large and small tube sizes Part Number

Description

ZE-497697

Zefon® Gemini® Twin Port Sampling Kit

Includes • Zefon® Gemini Twin-Port Sorbent Tube sampler • Tube protectors • Y-connectors • Clips • Carrying case

Zefon® Sorbent Tubes Zefon® Sorbent Tubes are high quality glass tubes that are packed with accurately weighed, high-purity sorbents. They are designed to adsorb vapors and gases passed over them when used with low flow sampling pumps and fit a variety of tube holders, including the Zefon® Gemini® Twin Port Sorbent Tube Sampler. Many Zefon® sorbent tubes are divided into sections, with two absorbent sections being most common. The first section is twice the size of the back section and collects the compounds of interest. The second section is a backup section to determine if airborne contaminants breakthrough occurred on the front section. Features • Highest sorbent material purity for contamination-free samples • Accurate sorbent weight for uniform testing results • Uniform pressure drop to assure repeatable sampling results • Designed to comply with all NIOSH specifications for tube dimensions, sorbent quality, particle size, divider composition and pore size Part Number

Sorbent

Size (O.D. x L)

Sections

Sorbent

Tube Ends

Separator*

SKC Equivalent

Quantity

ZE-ZST-001

Coconut Charcoal

6 mm x 70 mm

2

100 mg / 50 mg

GS

F/F/W

226-01

50/Box

ZE-ZST-001B

Coconut Charcoal

6 mm x 70 mm

2

100 mg / 50 mg

GS

F/F/W

226-01B

1000/Box

ZE-ZST-002

Coconut Charcoal

8 mm x 110 mm

2

400 mg / 200 mg

GS

F/F/W

226-09

50/Box

ZE-ZST-002B

Coconut Charcoal

8 mm x 110 mm

2

400 mg / 200 mg

GS

F/F/W

226-09B

1000/Box

ZE-ZST-003

Coconut Charcoal

10 mm x 110 mm

2

800 mg / 200 mg

GS

F/W/W

226-16

50/Box

ZE-ZST-020

Chromosorb

8 mm x 110 mm

2

100 mg / 50 mg

GS

W/W/W

226-107

50/Box

ZE-ZST-040

Microlite*

6 mm X 70 mm

1

200 mg

GS

W/W

226-17-1A

50/Box

ZE-ZST-050

Silica Gel

6 mm X 70 mm

2

150 mg / 75 mg

GS

F/W/W

226-10

50/Box

ZE-ZST-051

Silica Gel

6 mm X 70 mm

2

100 mg / 50 mg

GS

F/W/W

226-51

50/Box

ZE-ZST-054

Silica Gel

8 mm x 110 mm

2

520 mg / 360 mg

GS

W/W/W

226-10-04

50/Box

ZE-ZST-058

Silica Gel

10 mm X 110 mm

2

1040 mg / 260 mg

GS

F/W/W

226-22

50/Box

ZE-ZST-060

Silica Gel (specially cleaned)

7 mm X 110 mm

2

400 mg / 200 mg

GS

W/W/G/W

226-10-03

50/Box

ZE-ZST-080

XAD-2

8 mm x 110 mm

2

100 mg / 50 mg

GS

W/W/W

226-30-04

50/Box

ZE-ZST-090

XAD-7

6 mm X 110 mm

2

100 mg / 50 mg

GS

W/W/W

226-95

50/Box

* Microlite sorbent is equivalent to Hydrar, Carulite, and the SKC Anasorb C300.

Tube Ends Separator Codes GS: Glass sealed W: Glass Wool GO: Glass open G: Glass Fiber Filter F: Polyurethane Foam

AIR SAMPLING

27


AIR SAMPLING

Personal Pump Accessories

ZE-456226

CY-8860-4335

ZE-ZA0005

ZE-ZA0061

ZE-ZA0046

ZE-ZA0010

ZE-459743 10 mm O.D. x 220mm L

10 mm O.D. x 150 mm L 8 mm O.D. x 110 mm L 6 mm O.D. x 70 mm L

GIL-7015377P

Sample Tubing

APB-109030

Part Number

Description

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

ZE-456226

3/8'' O.D. x 1/4'' I.D. x 36" Long PVC Tubing With Tube Clip

Tube Covers

Cassette Accessories Part Number

Description

ZE-ZA0046

Cassette Opener For 25 mm, 37 mm & Air-O-Cell® Cassettes

ZE-ZA0049

Cassette Opener For 47 mm & Air-O-Cell® Cassettes

ZE-ZA0061

Universal Cassette/Cyclone Holder, Each

ZE-ZA0005

Plastic Luer Adapters, 10/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-459743

Metal Luer Adapters, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-ZA0010

25 mm Conductive Filter Transport Case

Buck Low Flow Sorbent Tube Holders Available both with and without flow adjustment. Use non-adjustable when using a sampling pump designed specifically for low flow sampling without adapters. Use adjustable flow to use with standard sampling pumps in constant pressure mode. Tube holder comes setup for 6 mm x 70 mm tubes. Additional size tube covers maybe purchased separately. Sorbent Tube Accessories

28

Part Number

Description

GIL-7015377P

Tube Tip Breaker, 5/Pack

APB-109032

Single Tube Holder With Non-Adjustable Flow

APB-109030

Single Tube Holder With Adjustable Flow (5 - 800 cc/min)

APB-109033

Single Tube Holder With Adjustable Flow (5 - 100 cc/min)

APB-109022

6 mm O.D. x 70 mm L Tube Cover

APB-109024

8 mm O.D. x 110 mm L Tube Cover

APB-109026

10 mm O.D. x 150 mm L Tube Cover

APB-109028

10 mm O.D. x 220 mm L Tube Cover

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


ZE-03113

AIR SAMPLING

Area Pump Replacement Parts

ZE-03180

ZE-03200

ZE-03184

ZE-03179

For Zefon® High Volume Diaphragm Area Sampling Pump Part Number

Description

ZE-03113

1/8" Air Flow Regulator Valve

ZE-03180

1/8" To 1/4" Conversion Fitting

ZE-03200

1/4" Hose Barb

ZE-03184

Rubber Foot For Diaphragm Pumps

ZE-03179

Muffler For Diaphragm Pump

ZE-03113

ZE-03200

ZE-03201

ZE-9800-52

ZE-ZGHV01

ZE-AA928

For Zefon® High Volume Rotary Vane Sampling Pump Part Number

Description

ZE-03113

1/8" Air Flow Regulator Valve

ZE-03200

1/4" Hose Barb

ZE-03201

Rubber Foot For ZE-ZHV00 Pump

ZE-AL-9800-52

Exhaust Filter For ZE-ZHV00 Pump

ZE-ZGHV01

Glass Muffler Jar For ZE-ZHV00 Pump

ZE-AA928

Felt Filters For ZE-ZHV00 Pump

Area Pump Accessories

EMS-200550

CY-8860-4335

Part Number

Description

EMS-200550

Premium Telescopic Sampling Tripod Stand

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

ZE-ZA0005

Plastic Luer Adapter, 10/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-459743

Metal Luer Adapter, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-ZA0005

ZE-459743

AIR SAMPLING

29


AIR SAMPLING

Air Sampling Bag Selection Guide

Choosing The Best Film For Your Gas Sampling Bag Needs Properties

30

Advantages

Limitations

Tedlar®

• Low gas permeation • High tensile strength • Max. operating temp: 400°F • Unaffected by the chemical components of gases commonly sampled

• Less permeable than FEP, PFA and TFM • Bags resist puncture in the field • Less expensive than FEP, PFA, TFM film

• Exhibits background levels of DMAC and phenol • High permeation rate for CO2 • Relatively high permeation rate for O2

ALTEF

• Developed specifically for gas sampling applications • Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols • Max. operating temp: 260°F • Made of 0.003" thick film

• Suitable for sampling most VOC's and many sulfur compounds • Low VOC background • Longer sample storage times than most other bag materials • Does not exhibit background levels of DMAC or phenol • Lower permeability than Tedlar® to CO2, N2, and CH4 • Superior resistance to solvents

• More permeable to most compounds than Tedlar® • Not suitable for sampling ketones and esters in high concentrations (>30%) • Less resistance to UV light than Tedlar® • Many sulfur compounds must be analyzed within 24 hours. • More expensive than Tedlar®

Multi-layer Foil

• Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2 • Foil layers provide very low permeability and complete moisture barrier • Max. operating temp: 190°F • Opaqueness protects samples from ultraviolet light

• The only bag material that adequately holds H2S for long periods • Ideal for collecting low molecular weight compounds • Sample stability up to 5 days for most compounds • Very low permeability to O2 and CO2 • Good VOC stability • Less expensive than Tedlar® and ALTEF

• Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials • Recommend analyzing within 48 hours after collection for CH4, H2S, CO, and CO2

FEP

• One of the most chemically inert materials available for making gas sampling bags • Max operating temperature: 400°F • Virtually transparent

• Works well in extreme temperatures from -400°F to 400°F • Heavier gauge film is resistant to most severe corrosives as well as tolerates applications involving rough handling or difficult service conditions • Less expensive than PFA

• Poor long term storage stability for most VOC's and sulfur compounds • Much more permeable and more expensive than Tedlar®, ALTEF, and MultiLayer Foil bags • Lower tensile strength than Tedlar®

PFA

• Highest purity, most chemically inert film available for making gas sampling bags • Wide temp range -420°F to 500°F

• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids • Temps from –400°F to 500°F

• Poor long term storage stability for most VOC's and sulfur compounds • The most expensive film option for gas sampling bags • Much more permeable than Tedlar®

TFM

• High purity, flexible, low permeation versus FEP and PFA • Translucent • Wide temperature range; from –328°F to 500°F

• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids • Sample stability for 4 to 5 days for most compounds • Withstands temperatures from –400°F to 500°F

• Expensive • Tears easily • Low tensile strength • More permeable than Tedlar®, ALTEF, and Multi-Layer foil bags

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Polypropylene Screw Cap Combo Valve with Replaceable Septum

Polypropylene Locking Combo Vakve with Septum

Nickel Plated HR Barbed On/Off Valve

Stainless Steel TCLP Fitting with Replaceable Septum

Stainless Steel Push/Pull Valve

Plastic Jaco Plating for Tubing or Septum

PFA Fitting Tubing or Septum

AIR SAMPLING

Valves And Fittings For Gas Sampling Bags

Swagelok Type Stainless Steel Fitting for Tubing or Septum

PTFE On/Off Valve with Stopcock

Valves and Fittings

Features

Polypropylene Screw Cap Combo Valve With Replaceable Septum

• On/Off valve function with replaceable septum in a single unit • Made of Inert polypropylene • Quick turning screw cap to open and close valve • Visual confirmation that valve is open or closed

Polypropylene Locking® Combo Valve With Septum

• On/Off valve function with septum in a single unit • Made of Inert polypropylene • Push/Pull (On/Off) valve stem • Quick Locking function, in closed position Fluoropolymer faced septum, with Ultra-low bleed silicone

Stainless Steel TCLP Fitting With Replaceable Septum

• Stainless steel body construction with aluminum cap • Designed for use with Zero Headspace Extractors • Replaceable fluoropolymer faced septum

Swagelok® Type Stainless Steel Fitting For Tubing Or Septum

• Stainless steel construction • Option of cap for tubing or septum • Replaceable fluoropolymer faced septum with large area

Nickel Plated Halkey® Roberts Barbed On/Off Valve

• Barbed stem for attaching tubing • Leak resistant seal in closed position

Plastic Jaco® Fitting For Tubing Or Septum

• Compression ferrule secures tubing onto fitting • Polypropylene molded construction • Option of cap for tubing, or cap with septum • Replaceable fluoropolymer faced septum with large area

PFA Fitting For Tubing Or Septum

• PFA fluoropolymer construction • Option of cap for tubing, or cap with septum • Compression ferrule secures tubing onto fitting • Replaceable fluoropolymer faced septum with large area

Tedlar® Gas Sampling Bag With Screw Cap Combo Valve With Replaceable Septum Part Number

Capacity

Size

Stem O.D.

Quantity

Part Number

Capacity

Size

Stem O.D.

Quantity

JIP-GSTP00-0606NSG1B

0.6 Liter

6" x 6"

3/16"

10/Pack

JIP-GSTP12-1221NSG1B

12 Liter

12" x 21"

3/16"

10/Pack

JIP-GSTP010707NSG1B

1 Liter

7" x 7"

3/16"

10/Pack

JIP-GSTP16-1818NSG1B

16 Liter

18" x 18"

3/16"

10/Pack

JIP-GSTP00-0610NSG1B

1.2 Liter

6" x 6"

3/16"

10/Pack

JIP-GSTP25-1824NSG1B

25 Liter

18" x 24"

3/16"

10/Pack

JIP-GSTP02-0909NSG1B

2 Liter

9" x 9"

3/16"

10/Pack

JIP-GSTP40-2424NSG1B

40 Liter

24" x 24"

3/16"

10/Pack

JIP-GSTP03-1010NSG1B

3 Liter

10" x 10"

3/16"

10/Pack

JIP-GSTP56-2430NSG1B

56 Liter

24" x 30"

3/16"

10/Pack

JIP-GSTP05-1212NSG1B

5 Liter

12" x 12"

3/16"

10/Pack

JIP-GSTP73-2436NSG1B

73 Liter

24" x 36"

3/16"

10/Pack

JIP-GSTP07-1215NSG1B

7 Liter

12" x 15"

3/16"

10/Pack

JIP-GSTP80-3030NSG1B

80 Liter

30" x 30"

3/16"

10/Pack

JIP-GSTP08-1217NSG1B

8 Liter

12" x 17"

3/16"

10/Pack

JIP-GSTP1003036NSG1B

100 Liter

30" x 36"

3/16"

10/Pack

JIP-GSTP09-1218NSG1B

9.5 Liter

12" x 18"

3/16"

10/Pack

JIP-SEP5007-NSCV-10

Replacement Septa

JIP-GSTP10-1219NSG1B

10 Liter

12" x 19"

3/16"

10/Pack

10/Pack

AIR SAMPLING

31


AIR SAMPLING

REPAIR AND CALIBRATION SERVICES ERE is the Ultimate source in Environmental Equipment. This reputation also demands ultimate service for the equipment. You can rely on ERE’s service department for timely repair and/or calibration of instruments and equipment. Whether it’s a routine calibration, maintenance or repair, come and join us! The coffee is on us!

32

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


You can order by phone, fax, email, and internet. Our customer service staff will be happy to assist you.

Tel: 514-326-8852 1-888-287-EREC (3732) Email: sales@ereinc.com Web: www.ereinc.com

Register online today and receive our monthly promotions and product updates. Discounts available for bulk orders or yearly contracts.

Our products are subject to change

ier

OUR STORE

am arc he Ru eL

Ru eB

om ba r

Parc Lucie-Bruneau

Ru eC

ham

pd

’Ea u

8605 Champ d’Eau Montréal, Quebec, Canada H1P 3B8 Tel: 514-326-8852 • Fax: 514-326-8961 Monday–Friday 8:00 AM to 4:30 PM


AIR S A M P L I N G

V O L . 5

Profile for ERE Inc

Air sampling-2019  

Air sampling-2019  

Profile for ere-inc