Air complete catalog

from ERE Inc

Scroll for more

Page 1

AIR

V O L . 5

SAMPLING MONITORING F I LT R AT I O N T R E AT M E N T


AIR SAMPLING

AIR SAMPLING PUMPS

4

CALIBRATORS & ROTAMETERS

14

IAQ, BIOAEROSOL & MICROBIOLOGICAL SAMPLERS

16

IMPACTORS & CYCLONES

19

CALIBRATION ACCESSORIES & SURFACE SAMPLERS

21

CASSETTES

22

TUBES & TUBE HOLDERS

27

PERSONAL & AREA PUMP ACCESSORIES

28

GAS SAMPLING BAGS

30

AIR MONITORING PASSIVE MONITORING BADGES

32

COLORIMETRIC TUBES & PUMPS

34

SINGLE GAS DETECTORS

38

MULTI-GAS DETECTORS

48

VOC DETECTORS

60

BENZENE DETECTORS

66

AIR ODOUR CONTROL NEUTRALIZER

70

HVAC FILTERS

70

MEDIA

70

AIR FILTRATION & TREATMENT

2

HVAC FILTERS

71

MEDIA

72

AIR TREATMENT SYSTEMS

75

See inside back cover for ordering information. 1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

WHY CHOOSE ERE?

AIR SAMPLING

3


AIR SAMPLING

Gilian® BDX-II Abatement Personal Air Sampling Pump The Gilian® BDX-II is designed specifically for asbestos and lead abatement applications when constant flow is not required. The built-in rotameter displays flow rates over the entire flow range of 0.5 - 3.0 LPM and an electronic flow control adjustment enables parts to last longer so maintenance is minimized. Sealed flow adjustment and on/off switch protects the Gilian® BDX-II from moisture, dust and fibers. Features • Flow rate: 500 - 3,000 cc/min (total) • Built-in rotameter • Will operate 10 hours at 2.0 LPM with inlet pressure of 20" • Rechargeable NiMH battery pack • Certifications: Not Intrinsic Safe

Available To Rent Part Number

Description

Flow Rate (Total)

Power Source

GIL-801863-171-1201

Gilian® BDX-II Starter Kit

500 - 3,000 cc/min

120V

GIL-100421

Gilian BDX-II 5-Pump Kit With 5-Unit Chargers

500 - 3,000 cc/min

120V

GIL-100423

Gilian® BDX-II 5-Pump Kit With 5-Station Charger

500 - 3,000 cc/min

120V

GIL-800511

17.5" x 13" x 7" Carrying Case

-

-

Inf Z

®

5-Pump Kit Includes • (5) Gilian® BDX-II pumps • (5) Pieces of 36" tubing • (5) Clip assemblies • (5) Reversible screwdrivers • (5) Single unit chargers (GIL-100421) or a 5-station charger (GIL-100423) • (5) User manuals • Heavy-duty foam lined carrying case

Differences Between Basic, Clock, & Programmable Models

ne

• The Basic model is straight-forward and easy to use. • Clock models provide an elapsed-time clock display. • Programmable models enable a timer which can start or stop the pump at preset time intervals or program a delayed start.

Gilian® LFS-113 Compact, Pocket-Sized, Personal Low Flow Air Sampling Pump The Gilian® LFS-113 is designed for flow rates between 1 - 350 cc/min, perfect for very low flow application sampling with sorbent tubes. Offers two user selectable sampling modes; the constant flow control mode holds the flow within ±5% of the set flow while the constant pressure control mode (multi-flow) allows multiple samples to be taken simultaneously through the use of a multi-flow manifold. No other pocket-sized pump matches the wide flow range and high back-pressure capability of the Gilian® LFS-113. Features • Flow rate: 1 - 350 cc/min (total) • Dual mode automatic constant flow or constant pressure control • Flow fault indicator light • Clock model/elapsed time display • Battery check LED • Rechargeable NiMH battery pack • Certifications: ATEX, CSA, C-US & UL Approvals - Intrinsic Safe

4

Starter Kit Includes • Gilian® BDX-II pump • 36" tubing • Clip assembly • Reversible screwdriver • Single unit charger • User manual

Starter Kit Includes • Gilian® LFS-113 pump • 36" tubing • Air boss kit • Single tube holder • Reversible screwdriver • Single unit charger • User manual

5-Pump Kit Includes • (5) Gilian® LFS-113 pumps • (5) Pieces of 36" tubing • (5) Air boss kits • (5) Single tube holders • (5) Reversible screwdrivers • 5-Unit charger • (5) User manuals

Part Number

Description

Model

Flow Rate

Power Source

GIL-910-0301-01

Gilian® LFS-113 D Starter Kit

Basic

1 - 350 cc/min

120V

GIL-910-0302-01

Gilian® LFS-113 D 5-Pump Kit

Basic

1 - 350 cc/min

120V

GIL-910-0303-01

Gilian® LFS-113 DC Starter Kit

Clock

1 - 350 cc/min

120V

GIL-910-0304-01

Gilian LFS-113 DC 5-Pump Kit

Clock

1 - 350 cc/min

120V

GIL-800400

18" x 13" x 7" Carrying Case

-

-

-

®

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Gilian® GilAir-3 & Gilian® GilAir-5 Personal Air Sampling Pumps The Gilian® GilAir-3 and Gilian® GilAir-5 pumps are suitable not only for conventional pull-through sampling media but also for bag sampling and other pressure applications. These 3 and 5 LPM air sampling pumps have automatic constant flow compensation, assuring sampling is maintained within ±5% of the initial set point, even with varying back-pressures from flow restrictions or buildup of material on the filter. Features • Flow rate: Gilian® GilAir-3: 1- 3,000 cc/min (total) Gilian® GilAir-5: 1- 5,000 cc/min (total) • Optional low flow modules • Flow fault & test indicators • External filter housing • Rechargeable NiMH battery pack • Certifications: UL - Intrinsic Safe

Part Number

Description

Model

Flow Rate (Total)

Power Source

GIL-800485-171-1201

Gilian® GilAir-3 R Starter Kit

Basic

1 - 3,000 cc/min

120V

GIL-800485-171-1205

Gilian GilAir-3 R 5-Pump Kit With 5-Unit Charger

Basic

1 - 3,000 cc/min

120V

GIL-800508-171-1201

Gilian® GilAir-3 RC Starter Kit

Clock

1 - 3,000 cc/min

120V

GIL-800508-171-1205

Gilian® GilAir-3 RC 5-Pump Kit With 5-Unit Charger

Clock

1 - 3,000 cc/min

120V

GIL-800510-171-1201

Gilian GilAir-3 RP Starter Kit

Programmable

1 - 3,000 cc/min

120V

GIL- 800510-171-1205

Gilian® GilAir-3 RP 5-Pump Kit With 5-Unit Charger

Programmable

1 - 3,000 cc/min

120V

GIL-800883-171-1201

Gilian GilAir-5 R Starter Kit

Basic

1 - 5,000 cc/min

120V

GIL-800883-171-1205

Gilian® GilAir-5 R 5-Pump Kit With 5-Unit Charger

Basic

1 - 5,000 cc/min

120V

GIL-800885-171-1201

Gilian® GilAir-5 RC Starter Kit

Clock

1 - 5,000 cc/min

120V

GIL- 800885-171-1205

Gilian GilAir-5 RC 5-Pump Kit With 5-Unit Charger

Clock

1 - 5,000 cc/min

120V

GIL-800884-171-1201

Gilian® GilAir-5 RP Starter Kit

Programmable

1 - 5,000 cc/min

120V

GIL-800884-171-1205

Gilian GilAir-5 RP 5-Pump Kit With 5-Unit Charger

Programmable

1 - 5,000 cc/min

120V

GIL-800511

17.5" x 13" x 7" Carrying Case

-

-

-

®

®

®

®

®

Starter Kit Includes • Gilian® GilAir-3 or Gilian® GilAir-5 pump • 36" tubing • Air boss kit • Filter cassette holder • Reversible screwdriver • Single unit charger • User manual 5-Pump Kit Includes • (5) Gilian® GilAir-3 or Gilian® GilAir-5 pumps • (5) Pieces of 36" tubing • (5) Air boss kit • (5) Filter cassette holder • (5) Reversible screwdriver • 5-Unit charger • (5) User manual • Carrying case

Need Help Deciding On A Pump? Answer the following questions to help narrow it down. 1. What flow rate do you require? 2. What sampling method are you using? • Bags (need an exhaust port) • Tubes • Cassettes 3. What gas (or gases) are you sampling for?

4. Will you need a calibrator? 5. Extra bells and whistles? • Data logging • Bluetooth • Programmable • Etc.

AIR SAMPLING

5


AIR SAMPLING

Gilian® GilAir® Plus Personal Air Sampling Pump The Gilian® GilAir® Plus is the world’s most capable air sampling pump now with 3 new technologies such as Motion Detection, BluetoothTM Connectivity and the CONNECT Mobile App! Three models to choose from; the basic model, the datalogging pump (DL) model and the standard temperature and pressure (STP) model. Features • Flow rate: 1 - 5,100 cc/min (total) • Flow modes: constant flow or high and low flow constant pressure • QuadModeSM air sampling technology • Selectable automatic fault recovery • SmartCalSM automatic calibration • High back pressure capability • Temperature & pressure compensation • Rechargeable NiMH battery pack • Certifications: EN 1232 Compliant, ISO 13137:2013 Compliant, Intrinsic Safe, US/Canada NRTL (FM), ATEX, CE Applicable Directives

Starter Kit Includes • Gilian® GilAir® Plus pump • Tubing • Filter cassette holder • Charcoal tube holder • 2 mm hex key • Charging dock with power adapter • User manual • Single unit carrying case • Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software

Available To Rent

5-Pump Kit Includes • (5) Gilian® GilAir® Plus pumps • (5) Pieces of tubing • (5) Filter cassette holders • (5) Charcoal tube holders • (5) 2 mm hex keys • Charging dock with power adapter • 5-Unit power station • (5) User manuals • 5-Unit carrying case • Data logging and STP models also include a communication enabled charging dock & Gilian® pump management software

Part Number

Description

Model

Flow Rate (Total)

Power Source

GIL-910-0901-US-R

Gilian® GilAir® Plus Starter Kit

Basic

1 - 5,100 cc/min

120V

GIL-910-0904-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

Basic

1 - 5,100 cc/min

120V

GIL-910-0902-US-R

Gilian® GilAir® Plus Starter Kit

Data Logging

1 - 5,100 cc/min

120V

GIL-910-0905-US-R

Gilian GilAir Plus 5-Pump Kit With 5-Unit Power Station

Data Logging

1 - 5,100 cc/min

120V

GIL-910-0910-US-R

Gilian® GilAir® Plus Starter Kit

BT Data Logging

1 - 5,100 cc/min

120V

GIL-910-0912-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

BT Data Logging

1 - 5,100 cc/min

120V

GIL-910-0903-US-R

Gilian GilAir Plus Starter Kit

STP

1 - 5,100 cc/min

120V

GIL-910-0906-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

STP

1 - 5,100 cc/min

120V

GIL-910-0911-US-R

Gilian GilAir Plus Starter Kit

BT STP

1 - 5,100 cc/min

120V

GIL-910-0913-US-R

Gilian® GilAir® Plus 5-Pump Kit With 5-Unit Power Station

BT STP

1 - 5,100 cc/min

120V

®

®

®

®

®

®

*3-Pump kits also available

Inf Z 6

Differences Between Basic, Data Logging, & STP Models

ne

• The basic model is straight forward and easy to use. • The data logging model provides additional advanced program functions and allows data logging and transferring of data to a PC. Also available with BluetoothTM option. • The STP model refers to standard temperature and pressure. These models correct the display flow rate and air volume to standard conditions of temperature and pressure. Also available with BluetoothTM option.

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Gilian® Power Series Personal Air Sampling Pumps The Gilian® Power Series is the industry leader in back pressure performance, reliability and ease-of-use. They also provide automatic constant flow controls and the Gilian® 5000 has an optional adapter module, which can handle lower flows under constant pressure control, such as required for multi-flow sorbent sampling. Features • Flow rate: Gilian® 800i: 200 - 800 cc/min (total) Gilian® 5000: 20 - 5,000 cc/min (total) Gilian® 10i: 4,000 - 10,000 cc/min (total) Gilian® 12: 4,000 - 12,000 cc/min (total) • Highest back-pressure capability • Programmable • Live flow display • Rechargeable NiMH battery pack • Certifications: Gilian® 800i, Gilian® 5000 & Gilian® 10i: Intrinsic Safe, US/Canada NRTL (FM), ATEX & CE Applicable Gilian® 12: Not Instrinsic Safe

AIR SAMPLING

High Efficiency Air Sampling Pumps

Starter Kit Includes Model

Gilian® 800i

Gilian® 5000

Gilian® 10i

Gilian® 12

Includes

• Gilian® 800i pump • 1/4" x 36" tubing • Single unit charger • User manual

• Gilian® 5000 pump • Filter cassette holder • Single unit charger • User manual

• Gilian® 10i pump • 3/8" x 36" tubing • Single unit charger • User manual

• Gilian® 12 pump • 3/8" x 36" tubing • Single unit charger • User manual

Model

Gilian® 800i

Gilian® 5000

Gilian® 10i

Gilian® 12

Includes

• (5) Gilian 800i pumps • (5) Pieces of 1/4" x 36" tubing • 5-Unit power station • (5) User manuals • Carrying case

• (5) Gilian 5000 pumps • (5) Filter cassette holders • 5-Unit power station • (5) User manuals • Carrying case

• (5) Gilian 10i pumps • (5) Pieces of 3/8" x 36" tubing • 5-Unit power station • (5) User manuals • Carrying case

• (5) Gilian® 12 pumps • (5) Pieces of 3/8" x 36" tubing • 5-Unit power station • (5) User manuals • Carrying case

5-Pump Kit Includes ®

®

®

Part Number

Description

Flow Rate (Total)

Power Source

GIL-910-1301-US

Gilian 800i Starter Kit With US Cord

200 - 800 cc/min

120V/230V

GIL-910-1305-US

Gilian® 800i 5-Pump Kit With US Cord

200 - 800 cc/min

120V/230V

GIL-910-0802-01

Gilian 5000 Starter Kit With US Cord

20 - 5,000 cc/min

120V/240V

GIL- 910-0801-01

Gilian® 5000 5-Pump Kit With US Cord

20 - 5,000 cc/min

120V/240V

GIL-910-1501-US

Gilian® 10i Starter Kit With US Cord

4,000 - 10,000 cc/min

120V/240V

GIL-910-1505-US

Gilian 10i 5-Pump Kit With US Cord

4,000 - 10,000 cc/min

120V/240V

GIL-910-1601-US

Gilian® 12 Starter Kit With US Cord

4,000 - 12,000 cc/min

120V/240V

GIL-910-1605-US

Gilian 12 5-Pump Kit With US Cord

4,000 - 12,000 cc/min

120V/240V

®

®

®

®

AIR SAMPLING

7


AIR SAMPLING

Gilian® AirCon-2 Portable High Volume Constant Flow Area Air Sampling Pump The Gilian® AirCon-2 sampler is a high volume unit with an extended flow range, designed for collecting particulate in a given plant area. It is ideal for asbestos background and clearance sampling following NIOSH, OSHA or EPA methodology and for ambient dust monitoring. Features • Flow rate: 2 - 30 LPM (total) • Fully programmable • Touchpad & LCD display • Instant fault function • Instant pressure check • Operates off either AC or battery power • Certifications: Not Instrisic Safe

Includes • Gilian® AirCon-2 pump • Hose • Sampling mast • Support tip • User manual

Part Number

Description

Flow Rate (Total)

Power Source

GIL-801012-100

Gilian® Aircon-2 DC Programmable Area Air Sampling Pump Only

2 - 30 LPM

120V

GIL-801000-2

Power Module 120V/230V/DC With 120V Cord

GIL-801001

Lead Acid Gel 4-Hour Battery Pack Requires Power Module (GIL-80100-2) To Charge (Note: May Stack (2) For 8-Hour Operation)

-

-

GIL-801171-1

22'' x 16'' x 8'' Wheeled Carrying Case For AirCon-2

-

-

GIL-800270

Gilian Gilibrator -2 High Flow Kit

2 - 30 LPM

120V

®

®

Zefon® Escort® LC Personal Air Sampling Pump The Zefon® Escort® LC air sampling pump can be used with a variety of personal and area sampling devices to collect such airborne contaminants as asbestos fibers, toxic gases, vapors, particulates, fumes and mists. It can also be used to sample silica dust, coal dust and organic vapors. Features • Flow range: 0.5 - 3 LPM (total) • Inlet filter traps particulate matter • Separate LEDs indicate pump operation and low battery • Stainless steel-filled plastic case provides EMI/RFI protection • Rechargeable NiMH battery pack • Certifications: UL Approved as Intrinsically Safe for use in Hazardous Locations, Class I, Groups A, B, C, D; Class II, Groups E, F and G; Class III, Division I Locations Part Number

Description

Flow Rate (Total)

Power Source

ZE-711400

Zefon® Escort® LC With 120V Charger

0.5 - 3 LPM

120V

ZE-P5-ESLC-5-1-0-0

Zefon® Escort® LC 5-Pump Kit With 5-Unit Charger

0.5 - 3 LPM

120/240V

ZE-811741

Protective Leather Holster Case

-

-

Includes • Escort® LC pump • Sampling line • 120V charger • User manual 5-Pump Kit Includes • (5) Escort® LC pumps • (5) Sampling lines • 5-Unit charger • User manual • Carrying case

Personal Pump Accessories

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft CY-8860-4335

Sorbent Tube Holder APB-109030

Metal Luer Adapter ZE-459743

Please refer to page 28 for more information.

8

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

37mm Cassette Tubing Adapters ZE-ZA0005

36'' Sampling Line with Tube Clip ZE-456226

Universal Cassette or Cyclone Holder ZE-ZA0061


AIR SAMPLING

Zefon® Escort ELF® Personal Air Sampling Pump The Zefon® Escort ELF® air sampling pump features a state of the art electronic laminar flow sensor to provide a constant flow control with ± 2.5% regulation of flow rate from 1 - 3 LPM with automatic compensation for changes in battery voltage, temperature, altitude, and sample load. An internal secondary standard calibrates the pump continuously and needs to be checked against a primary standard only once per month (or every 200 hours for coal mine dust sampling). Features • Flow rate: 0.5 - 3 LPM (total) • Patented electronic laminar flow control • Inlet filter traps moisture and particular matter • Stainless steel-filled plastic case provides EMI/RFI protection • Rated IP65 for resistance to water and dust ingress • Flow fault indicator shows any sample inlet blockage • Run/Hold feature allows "time out" during sampling process • Elapsed time readout and low-battery warning • Low flow and dual tube sampling available with Zefon® Gemini Twin-Port Sampler • Rechargeable NiMH battery pack • Certifications: NIOSH, MSHA, UL, ATEX specific models only

Includes • Zefon® Escort ELF® pump • Sampling line • 120V charger • User manual 5-Pump Kit Includes • (5) Zefon® Escort ELF® pumps • (5) Sampling lines • 5-Unit charger • User manual • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

ZE-805560

Zefon® Escort ELF® With 120V Charger & Sampling Line

0.5 - 3 LPM

120V

ZE-805563

Zefon® Escort ELF® With 5-Unit Charger & Sampling Line

0.5 - 3 LPM

120/240V

ZE-805559

Zefon® Escort ELF® With 120V Charger & Gemini® Twin Port Sampler

0.5 - 3 LPM

120V

ZE-711396

Zefon Escort ELF With 5-Unit Charger & Gemini Twin Port Sampler

0.5 - 3 LPM

120/240V

ZE-811741

Protective Leather Holster Case

-

-

®

®

®

* 240V also available

Buck Libra™ L-4 Abatement Personal Air Sampling Pump The Buck Libra™ L-4 is designed for sampling of asbestos, lead, and other airborne contaminates. This pump is used to draw air contaminants in through a sampling media such as 25 and 37 mm filter cassettes which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 4.0 LPM for periods exceeding 8 hours. Low flows from 5 - 800 cc/min can be obtained using the optional Adjustable Universal Low Flow Holder. Features • Flow rate: 0.8 - 4.0 LPM (total) 5 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) • High impact steel fiber filled Lexan case, antistatic and RFI shielded • "Auto-Restart" within one minute of a flow fault • High backpressure capable for 25 mm 0.45 μm asbestos filters • Built-in washable stainless steel 100 μm filter for economy of use • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: CE EMC Directive (EMCD) 89/336/EEC

Part Number

Description

Flow Rate (Total)

Power Source

APB-926000

Buck Libra™ L-4 Starter Kit

0.8 - 4.0 LPM

120V

APB-942600

Buck Libra™ L-4 5-Pump Kit

0.8 - 4.0 LPM

120V

APB-109030

Adjustable Universal Low Flow Holder

-

-

Sarter Kit Includes • Buck Libra™ L-4 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Single pack NiMH battery • 120V charger • User manual

5-Pump Kit Includes • (5) Buck Libra™ L-4 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Single pack NiMH batteries • QuickFive™ charger 100-240V • (2) User manuals • Pelican carrying case model 1500

*230V also available

AIR SAMPLING

9


AIR SAMPLING

Buck Libra Plus™ Series Personal Air Sampling Pump The Buck Libra Plus™ is designed for sampling of asbestos, lead, and other airborne contaminates. These pumps display flow rate, elapsed time and accumulated volume of the sample. The Buck Libra Plus™ model LP-1 and LP-5 is used to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes whereas the Buck Libra Plus™ model LP-7, LP-12 and LP-20 can also use 47 mm filter cassettes; which is used to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. Features • Flow rate: Buck Libra Plus™ LP-1: 100 - 600 cc/min (total) 5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109033) Buck Libra Plus™ LP-5: 0.8 - 5.0 LPM (total) 5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Libra Plus™ LP-7: 3.0 - 7.0 LPM (total) Buck Libra Plus™ LP-12: 3.0 - 12.0 LPM (total) 50 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Libra Plus™ LP-20: 5.0 - 20.0 LPM (total) • Displays: elapsed time, accumulated volume and flow rate • "Auto-Restart" within one minute of a flow fault • High backpressure capable for 25 mm 0.45 μm asbestos filters • Built-in washable stainless steel 100 μm filter for economy of use • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: CE EMC Directive (EMCD) 89/336/EEC Starter Kit Includes Model

Buck Libra Plus™ LP-1, LP-5 & LP-7

Buck Libra Plus™ LP-12

Buck Libra Plus™ LP-20

Includes

• Buck Libra Plus™ LP-1, LP-5 or LP-7 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-adjustable tube holder • Single pack NiMH battery • Standard 120V battery charger • User manual

• Buck Libra Plus™ LP-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-adjustable tube holder • Triple pack NiMH battery • Standard 120V battery charger • User manual

• Buck Libra Plus™ LP-20 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-adjustable tube holder • Triple pack NiMH battery • Standard 120V battery charger • User manual

5-Pump Kit Includes Model

Buck Libra Plus™ LP-1, LP-5 & LP-7

Buck Libra Plus™ LP-12

Buck Libra Plus™ LP-20

Includes

• (5) Buck Libra Plus™ LP-1, LP-5 or LP-7 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Non-adjustable tube holder • (5) Single pack NiMH batteries • Quick(5)™ charger 100-240V • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Libra Plus™ LP-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Non-adjustable tube holder • (5) Triple pack NiMH batteries • Quick(5)™ charger 100-240V • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Libra Plus™ LP-20 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Non-adjustable tube holder • (5) Triple pack NiMH batteries • Quick(5)™ charger 100-240V • (2) User manuals • Pelican carrying case model 1600

Part Number

Description

Flow Rate (Total)

Power Source

APB-906800

Buck Libra Plus™ LP-1 Starter Kit

100 - 600 cc/min

120V

APB-946500

Buck Libra Plus™ LP-1 5-Pump Kit

100 - 600 cc/min

120V

APB-906200

Buck Libra Plus™ LP-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-946200

Buck Libra Plus™ LP-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-906300

Buck Libra Plus™ LP-7 Starter Kit

3.0 - 7.0 LPM

120V

APB-942507

Buck Libra Plus™ LP-7 5-Pump Kit

3.0 - 7.0 LPM

120V

APB-906250

Buck Libra Plus™ LP-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-942512

Buck Libra Plus™ LP-12 5-Pump Kit

3.0 - 12.0 LPM

120V

APB-906700

Buck Libra Plus™ LP-20 Starter Kit

5.0 - 20.0 LPM

120V

APB-942520

Buck Libra Plus™ LP-20 5-Pump Kit

5.0 - 20.0 LPM

120V

APB-109033

Adjustable Universal Low Flow Holder

5 - 100 cc/min

-

APB-109030

Adjustable Universal Low Flow Holder

5 - 800 cc/min

-

*230V also available

10

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Buck Elite™ Personal Air Sampling Pump The Buck Elite™ series personal air sampling pump draws air contaminants in through a sampling media such as sorbent tubes, bubble impingers, long duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 0.6 LPM. Low flows from 5 - 99 cc/min can be obtained using the optional Low Flow Holder. Features • Flow rate: Buck Elite™-1: 0.005 - 0.6 LPM (total) 5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109033) Buck Elite™-5: 0.8 - 5.0 LPM (total) 5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Elite™-12: 3.0 -12.0 LPM (total) 50 - 800 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) • Capable for data logging and programmable for multiple "Start/ Stop" and duration sampling • Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case • Exclusive electronic circuit board for constant flow control • "Auto-Restart” within one minute of a flow fault • High backpressure compensation up to 36” of w.c. @ 300 cc/min • Flow compensation for filter plugging and battery voltage • Key pad lock system • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: CE EMC Directive (EMCD) 89/336/EEC

Starter Kit Includes Model

Buck Elite™-1

Buck Elite™-5

Buck Elite™-12

Includes

• Buck Elite™-1 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Non-Adjustable Low Flow Holder • Single pack NiMH battery • Standard 120V charger • User manual

• Buck Elite™-5 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Single pack NiMH battery • Standard 120V charger • User manual

• Buck Elite™-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip • Triple pack NiMH battery • Standard 120V charger • User manual

5-Pump Kit Includes Model

Buck Elite™-1

Buck Elite™-5

Buck Elite™-12

Includes

• (5) Buck Elite™-1 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Non-Adjustable Low Flow Holders • (5) Single pack NiMH batteries • Quick(5)™ 100-240V charger • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Elite™-5 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Single pack NiMH batteries • Quick(5)™ 100-240V charger • (2) User manuals • Pelican carrying case model 1500

• (5) Buck Elite™-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Triple pack NiMH batteries • Quick(5)™ 100-240V charger • (2) User manuals • Pelican carrying case model 1600

Part Number

Description

Flow Rate (Total)

Power Source

APB-908100

Buck Elite™-1 Starter Kit

0.005 - 0.6 LPM

120V

APB-947300

Buck Elite™-1 5-Pump Kit

0.005 - 0.6 LPM

120V

APB-908000

Buck Elite™-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-947200

Buck Elite™-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-908300

Buck Elite™-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-948000

Buck Elite™-12 5-Pump Kit

3.0 - 12.0 LPM

120V

APB-109033

Adjustable Universal Low Flow Holder

5 - 100 cc/min

-

APB-109030

Adjustable Universal Low Flow Holder

5 - 800 cc/min

-

*230V also available

AIR SAMPLING

11


AIR SAMPLING

Buck Allin™ & Buck Allin™ Plus Intrinsically Safe Personal Low Flow Air Sampling Pump The Buck Allin™ & Buck Allin™ Plus series is a personal air sampler suitable for use in locations where flammable gases, vapors, dust, fibers or flying’s are present. The purpose of this pump is to draw air contaminants in through a sampling media such as 25 mm and 37 mm filter cassettes, bubble impingers, long-duration color detector tubes; to gauge personnel exposure to gases, vapors, particulates, aerosols, etc. It is capable of delivering up to 5.0 LPM. Low flows from 5 - 799 cc/min can be obtained using the optional Low Flow Holder. Features • Flow rate: Buck Allin™-1 & Buck Allin™ Plus-1: 0.1 - 0.6 LPM (total) 5 - 99 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Allin™-5 & Buck Allin™ Plus-5: 0.8 - 5.0 LPM (total) 5 - 799 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) Buck Allin™-12 & Buck Allin™ Plus-12: 3.0 -12.0 LPM (total) 50 - 2999 cc/min with optional Adjustable Universal Low Flow Holder (APB-109030) • Buck Allin™ Plus models are capable of data logging and can be programmed for multiple "Start/ Stop" and duration sampling • Buck Allin™ Plus models allows temperature and barometric pressure compensation in STP mode • Steel fiber filled Lexan, antistatic, and RFI/EMI-shielded case • Exclusive electronic circuit board for constant flow control • "Auto-Restart" within one minute of a flow fault • High backpressure compensation up to 50" of w.c. @ 2 LPM • Flow compensation for filter plugging and battery voltage • Key pad lock system • Stainless steel belt clip with built-in tripod connector • Rechargeable NiMH battery pack • Certifications: UL 913 & CAN/CSA-C22.2 Intrinsically Safe, suitable for use in Class I, II, III, Div 1 Groups A-G, T3 Hazardous Locations Starter Kit Includes Model

Buck Allin™-1, Buck Allin™-5 & Buck Allin™-12

Buck Allin™ Plus-1, Buck Allin™ Plus-5 & Buck Allin™ Plus-12

Includes

• Buck Allin™-1, Buck Allin™-5 or Buck Allin™-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip

• Buck Allin™ Plus-1, Buck Allin™ Plus-5 or Buck Allin™ Plus-12 pump • 3 ft of vinyl hose • Luer hose adapter • Shirt/hose clip

• Single pack NiMH battery • Standard 120V charger • User manual

• Low Flow Holder • Single pack NiMH battery • Standard 120V charger • User manual

5-Pump Kit Includes Model

Buck Allin™-1, Buck Allin™-5 & Buck Allin™-12

Includes

• (5) Buck Allin™-1, Buck Allin™-5 or Buck Allin™-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • (5) Single pack NiMH batteries

Buck Allin™ Plus-1, Buck Allin™ Plus-5 & Buck Allin™ Plus-12 • Standard 110-240V smart charger kit • (2) User manuals • Carrying case

• (5) Single pack NiMH batteries • Standard 110-240V smart charger kit • (2) User manuals • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

APB-905000

Buck Allin™-1 Starter Kit

0.1 - 0.6 LPM

120V

APB-905050

Buck Allin™-1 5-Pump Kit

0.1 - 0.6 LPM

120V

APB-905200

Buck Allin™-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-905250

Buck Allin™-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-905400

Buck Allin™-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-905450

Buck Allin™-12 5-Pump Kit

3.0 -12.0 LPM

120V

APB-905100

Buck Allin™ Plus-1 Starter Kit

0.1 - 0.6 LPM

120V

APB-905150

Buck Allin™ Plus-1 5-Pump Kit

0.1 - 0.6 LPM

120V

APB-905300

Buck Allin™ Plus-5 Starter Kit

0.8 - 5.0 LPM

120V

APB-905340

Buck Allin™ Plus-5 5-Pump Kit

0.8 - 5.0 LPM

120V

APB-905500

Buck Allin™ Plus-12 Starter Kit

3.0 - 12.0 LPM

120V

APB-905550

Buck Allin™ Plus-12 5-Pump Kit

3.0 - 12.0 LPM

120V

APB-109030

Adjustable Universal Low Flow Holder

5 - 800 cc/min

-

*230V also available

12

• (5) Buck Allin™ Plus-1, Buck Allin™ Plus-5 or Buck Allin™ Plus-12 pumps • (5) Pieces of 3 ft of vinyl hose • (5) Luer hose adapters • (5) Shirt/hose clips • Low Flow Holder

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Zefon® High Volume Diaphragm Area Sampling Pump The Zefon® 23 stroke High Volume Diaphragm area sampling pump is an economical workhorses with a flow range of 3 - 14 LPM. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes. 2-Pump Kit Includes • (2) Zefon® High Volume Diaphragm pumps with locking flow control valves • (2) pieces of 10 ft tubing • (2) Hose barbs • (2) On/Off switches • (2) Tripod stands • Heavy duty carrying case

Includes • Zefon® High Volume Diaphragm pump with locking flow control valve • 10 ft tubing • Hose barb • On/Off switch

Available To Rent

Part Number

Description

Flow Rate (Total)

Power Source

ZE-ZTHV01

Zefon® High Volume Diaphragm Pump

3 - 14 LPM

120V

ZE-ZTHV01-KIT

Zefon® High Volume Diaphragm 2-Pump Kit

3 - 14 LPM

120V

ZE-195380

1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

ZE-195505

3 - 30 LPM Zefon® Non-Adjustable High Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

-

-

EMS-200550

Premium Telescopic Sampling Tripod Stand

-

-

ZE-ZTHV00-KCASE

Carrying Case For ZTHV01 Pumps (Holds (2) ZTHV01 Pumps, (2) Stands & Tubing)

-

-

*220V also available *Please refer to page 27 for area pump replacement parts and area pump accessories

New! Now with internal filter/muffler. No more glass muffler jars! Zefon® High Volume Rotary Vane Sampling Pump The Zefon® High Volume Rotary Vane pump is an economical alternative to the Gast brand Rotary Vane pumps with a flow range of 0 - 30 LPM. The workhorses are heavy duty with a 1/10 hp motor that can be used for almost all sampling applications. Suitable for use with asbestos PCM, TEM, Air-O-Cell® and Via-Cell® cassettes along with all viable impactors (ex: Andersen style impactor). Flow Rates PCM cassette: 3 - 15 LPM TEM cassette: 3 - 10 LPM Air-O-Cell® cassette: 15 LPM Viable Impactor: 28.3 LPM

Includes • Zefon® High Volume Rotary Vane pump with flow control valve • 2 1/4" I.D. tubing set • On/Off switch

Available To Rent

2-Pump Kit Includes • (2) Zefon® High Volume Rotary Vane pumps with flow control valves • (2) 2 1/4" I.D. tubing sets • (2) On/Off switches • (2) Tripod stands • Heavy duty carrying case

Part Number

Description

Flow Rate (Total)

Power Source

ZE-ZHV00

Zefon High Volume Rotary Vane Pump

0 - 30 LPM

120V

ZE- ZHV00-KIT

Zefon® High Volume Rotary Vane 2-Pump Kit

0 - 30 LPM

120V

ZE-116116

0 - 4 LPM Zefon Non-Adjustable Low Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

ZE-195380

1 - 20 LPM Zefon® Non-Adjustable Medium Flow Field Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

ZE-195505

3 - 30 LPM Non-Adjustable High Flow Rotameter Includes: Hose Barb, Tygon® Tubing & Luer Adapter

-

-

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

-

-

®

®

EMS-200550

Premium Telescopic Sampling Tripod Stand

-

-

ZE-ZHV00-KCASE

Carrying Case For ZHV00 Pumps (Holds (2) ZHV00 Pumps, (2) Stands & Tubing)

-

-

*220V also available *Please refer to page 29 for area pump replacement parts and area pump accessories

AIR SAMPLING

13


AIR SAMPLING

Zefon® Non-Adjustable Field Rotameters The Zefon® Field Rotameters are a low cost way to measure airflow in air sampling applications. They feature a durable acrylic housing with direct reading scales printed on them. Available in three different flow ranges covering a range of 0.2 through 30 LPM. Operation and maintenance are very simple; only a few common sense precautions must be observed to assure long, trouble-free service. Part Number

Description

Flow Rate (Total)

ZE-116116

Zefon Non-Adjustable Low Flow Field Rotameter

0 - 4 LPM

ZE-195380

Zefon® Non-Adjustable Medium Flow Field Rotameter

1 - 20 LPM

ZE-195505

Zefon® Non-Adjustable High Flow Field Rotameter

3 - 30 LPM

®

Features • Scales are large (average 4" length) and easy to read • The direct reading scales are hot stamped into the plastic and will not wear off • Mid-range calibration is established with a master flowmeter, providing an accuracy of ±3% Includes • Zefon® Non-Adjustable Field Rotameter (low, medium or high) • Tygon® tubing • Hose barb • Luer adapter

Available To Rent

Gilian® Go-CalTM Air Flow Calibrator The Gilian® Go-Cal™ Air Flow Calibrator is a portable, battery-operated calibrator with a precision air flow calibration between 0.01 - 20 LPM and accuracy within 2% of reading. Go-Cal™ displays air flow rate continuously allowing adjustments to pump flowrate in real-time. The Go-Cal™ displayed flowrate is compensated for temperature making it easier to produce consistent results at various calibration locations. Part Number

Description

Flow Rate (Total)

GIL-811-9916-01

Gilian® Go-CalTM Air Flow Calibrator Kit

0.01 - 20 LPM

Includes • Gilian® Go-CalTM Air Flow Calibrator • Tubing kit • Battery pack including (6) AA size alkaline batteries

• NIST traceable calibration certificate • User manual • Carrying case

Accurate, Reliable & Portable Primary Calibrators for Fast Calibration of Air Sampling Pumps! Defender 500 Series Defender 510 Volumetric Primary Flow Standard Defender 520 Enhanced Volumetric Primary Flow Standard Defender 530+ Standardized & Volumetric Primary Flow Standard Instantly calibrate your air samplers using Quick Start - there is no preparation involved, no messy soap bubble solutions. Alternatively, set your Defender to take hands-free, continuous measurements while you quickly set the flow rate on your pumps. Defender’s many user-selectable options makes customizing your calibrations easy, giving you exactly what you need in the format you prefer. All you have to do is choose between the 510, the 520 or the 530. Defender 510

Defender 520

Defender 530+

Model and Flow Ranges

BIO-200-510L: 5 - 500 cc/min BIO-200-510M: 50 - 5,000 cc/min BIO-200-510H: 300 - 30,000 cc/min

BIO-200-520L: 5 - 500 cc/min BIO-200-520M: 50 - 5,000 cc/min BIO-200-520H: 300 - 30,000 cc/min

BIO-200-530L: 5 - 500 cc/min BIO-200-530M: 50 - 5,000 cc/min BIO-200-530H: 300 - 30,000 cc/min

Volumetric Accuracy

1%

1%

1%

Standardized Accuracy User Selectable Measurement Units

14

Available To Rent

N/A

N/A

1.2%

Volumetric

ml/min, L/min, cc/min, cf/min

ml/min, L/min, cc/min, cf/min

ml/min, L/min, cc/min, cf/min

Standardized

N/A

N/A

Temperature

N/A

o

o

Pressure

C oF

smL/min, sL/min, scc/min, scf/min C oF

N/A

mmHg, PSI, kPa

mmHg, PSI, kPa

Temperature and Pressure Sensor

No

Yes, in flow steam

Yes, in flow steam

Pressure Accuracy

N/A

3.5 mmHg (typical) 7.0 mm (max)

3.5 mmHg (typical) 7.0 mm (max)

Temperature Accuracy

N/A

0.8oC (typical) 1.3oC (max)

0.8oC (typical) 1.3oC (max)

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Three Flow Cells Available; Low, Standard & High Gilian® Gilibrator-2 The Gilian® Gilibrator-2 primary standard accuracy and performance validation for sampling pump airflows from 1 cc/min - 30 LPM. Features • Flow rate: Low Flow Cell: 1 - 250 cc/min (total) Standard Flow Cell: 20 - 6,000 cc/min (total) High Flow Cell: 2 - 30 LPM (total) • Consists of an electronic Gilibrator-2 base which is used with any of three sizes of flow cells • Cells use a twist-on bayonet design for quick and easy mounting to the base • These interchangeable cells generate perfect bubble films at the touch of a button • Infrared sensors read the bubble flow rate, which is then calculated and displayed • DC power source with internal battery pack • Certified for accuracy and traceable to NIST

Low, Standard & High Flow Cell Kit Includes • Control base • Flow cell (low, standard or high) • Tubing • Soap solution with dispenser • DC charger/AC power supply • Hard shell carry case

Deluxe Cell Kit Includes • Control base • Three interchangeable cells for low, standard and high flow rates • Tubing • Soap solution with dispenser • DC charger/AC power supply • Hard shell carry case

Part Number

Description

Flow Rate (Total)

GIL-800272

Gilian® Gilibrator-2 Low Flow Cell Kit With US Cord

1 - 250 cc/min

GIL-800271

Gilian® Gilibrator-2 Standard Flow Cell Kit With US Cord

20 - 6,000 cc/min

GIL-800270

Gilian Gilibrator-2 High Flow Cell Kit With US Cord

2 - 30 LPM

GIL-801804

Gilian® Gilibrator-2 Deluxe Cell Kit With All Three Cell Sizes & US Cord

1 - 250 cc/min, 20 - 6000 cc/min, 2 - 30 LPM

GIL-800450

Soap Solution Flow Cell For Gilian Gilibrator-2 Calibrator, 8 oz

-

®

®

Zefon® DigiCal™ Flow Calibrator The Zefon® DigiCal™ Flow Calibrator provides instantaneous calibration for instruments like the Zefon® Escort® LC pump or the secondary flow standard inside the Escort ELF® sampling pumps. Just press the plunger and the DigiCal™ calibrator does the work. Its unique flow cell replaces conventional bubble tubes and makes calibration easier. The DigiCal™ Calibrator achieves extreme accuracy by utilizing a computerized flow meter that provides instantaneous flow readouts on a digital display. Features • Flow rate: Zefon® DigiCal™ 5: 1 - 6,000 cc/min (total) Zefon® DigiCal™ 30: 0.1 - 30 LPM (total) • ± 0.5% accuracy • Microprocessor controlled to provide fast, accurate, repeatable measurements • Work at any altitude without correction • Instant readout of volumetric flow Includes • Zefon® DigiCal™ Flow Calibrator • Soap solution • Dispenser bottle • Charger • User manual

Part Number

Description

Flow Rate (total)

Power Source

ZE-655101

Zefon® DigiCal™ 5 Flow Calibrator

1 - 6,000 cc/min

110V

ZE-655130

Zefon DigiCal™ 30 Flow Calibrator

0.1 - 30 LPM

110V

ZE-655273

Soap Bubble Solution For Zefon® DigiCalTM Flow Calibrator, 8 oz

-

-

ZE-ZA0122

Pelican 1400 Carrying Case With Pick-N-Pluck Foam

-

-

®

AIR SAMPLING

15


AIR SAMPLING

Zefon® Bio-Pump® Plus The Zefon® Bio-Pump® Plus is the smallest, lightest and easiest to use portable, battery-powered IAQ pumps designed for exclusive use with Air-O-Cell® and Via-Cell® cassettes at a flow rate of 15 LPM. Features • Real time display showing actual run time • Programmable sample time (allows unattended operation) • "Sample Complete" audible & visual indicators • "Quick Sample" operation • Long Lasting NiMH battery provides approx. 8 hours of continuous run time or approx. 100 5-minute samples Model

Zefon® Bio-Pump® Plus Kit

Zefon® Bio-Pump® Plus Pro Kit

Zefon® Bio-Pump® Plus With TSI 4046 Calibrator Kit

Includes

• Zefon Bio-Pump Plus pump • Air flow indicator • (10) Air-O-Cell® cassettes • Charger • Warranty card • User manual • Carrying case

• Zefon Bio-Pump Plus pump • Air flow indicator • (10) Air-O-Cell® cassettes • (25) Bio-Tape™ slides • Bioisolation filter • Tripod stand • Charger • Warranty card • User manual • Carrying case

• Zefon® Bio-Pump® Plus pump • Air flow indicator • (10) Air-O-Cell® cassettes • TSI 4046 calibrator kit • Charger • Warranty card • User manual • Carrying case

®

®

®

®

Part Number

Description

Flow Rate (Total)

Sampling Media

Power Source

ZE-ZBP-205

Zefon® Bio-Pump® Plus With 110-230V Charger With North American Plug

15 LPM

(10) Air-O-Cell® Cassettes

120V

ZE-ZBP-PROKIT-PLUS

Zefon® Bio-Pump® Plus Pro Kit With Accessories

15 LPM

(10) Air-O-Cell® Cassettes (25) Bio-Tape™ Slides

120V

ZE-ZBP-205-CKIT

Zefon® Bio-Pump® Plus With TSI 4046 Calibrator Kit

15 LPM

(10) Air-O-Cell® Cassettes

120V

ZE-ZA0047

Bioisolation Filter For Zefon® Bio-Pump® Plus

-

-

-

ZE-ZA0043

Zefon Heavy Duty Tripod Stand For Zefon Bio-Pump Plus

-

-

-

®

®

* 230V also available

Zefon® Z-Lite™ IAQ Mold Sampling Starter Kits The Zefon® Z-Lite™ kits are an easy, convenient way to get everything you need to begin sampling for mold. It is a low maintenance-oscillating pump designed for use with all mold sampling cassettes and impactors.

Features • Flow rate: 3 - 33 LPM • Built-in adjustable flow meter/regulator • Rubber suction cup feet to prevent movement while in use

Model

Basic Kit

Deluxe Kit

Ultimate Kit

Includes

• Zefon Z-Lite™ pump with integrated combination flow meter/regulator valve • Tubing • (10) Air-O-Cell® • Bioisolation filter • Tripod stand • Basic set-up and user instructions • Toolbox style carrying case

• Zefon Z-Lite™ pump with integrated combination flow meter/regulator valve • Tubing • (20) Air-O-Cell® • (25) Bio-Tape™ slides • (10) Mold swabs • Bioisolation filter • Tripod stand • Basic set-up and user instructions • Toolbox style carrying case

• Zefon® Z-Lite™ pump with integrated combination flow meter/regulator valve • Tubing • (50) Air-O-Cell® • (50) Bio-Tape™ slides • (50) Mold swabs • (10) Inner wall attachments • Bioisolation filter • Tripod stand • Basic set-up and user instructions • Toolbox style carrying case

®

Part Number

Description

Flow Rate (Total)

Sampling Media

Power Source

ZE-Z-LITE-BMKIT

Zefon® Z-Lite™ IAQ Basic Mold Sampling Starter Kit

3 - 33 LPM

(10) Air-O-Cell® Cassettes

120V

ZE-Z-LITE-DMKIT

Zefon® Z-Lite™ IAQ Deluxe Mold Sampling Starter Kit

3 - 33 LPM

(20) Air-O-Cell® Cassettes (25) Bio-Tape™ Slides (10) Mold Swabs

120V

ZE-Z-LITE-UMKIT

Z-Lite™ IAQ Ultimate Mold Sampling Starter Kit

3 - 33 LPM

(50) Air-O-Cell® Cassettes (50) Bio-Tape™ Slides (50) Mold Swabs (10) Inner Wall Attachments

120V

* 230V also available

16

®

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


The Buck Bio-Series pumps are simple to operate and provides a selectable, continuous, and constant sample flowrate. Its quiet operation allows unobtrusive sampling in IAQ, medical, clean room, public, and residential building applications. The front key pad is organized into three functional key groups: Power (ONOFF), Timing (1, 2, 5, 10 minute samples) and Calibration (cal mode, increase flow, decrease flow). End of sample notice is provided by the lit LED "Complete" and three short beep.

Buck BioAire™ Bioaerosol Sampling Pump Features • Flow rate: 5 - 20 LPM • Small, lightweight, and compact • Accepts both Allergenco-D or Air-O-Cell® cassettes • NiCad batteries with 6 - 8 hours continuous run time at 15 LPM • Convenient timer for 1, 2, 5, 10 minute samples and continuous mode • End-of-cycle audible & visual • Easy keypad calibration without tools

AIR SAMPLING

Buck Bio-Series Pumps

Includes • Buck BioAire™ pump • Calibration rotameter assembly (APB-706100) • Standard smart 120V charger • User manual

Part Number

Description

Flow Rate (Total)

Power Source

APB-706000

Buck BioAire™ Pump Model B520

5 - 20 LPM

120V

APB-108000

Durable Hard Plastic Carrying Case With Foam Insert

-

-

Buck BioSlide™ Biocontaminent Sampling Pump Features • Flow rate: 10 - 20 LPM • Small, lightweight, and compact • Accepts generic greased slides • NiCad batteries with 5 - 6 hours continuous run time at 15 LPM • End-of-cycle and battery level audible & visual • Tripod mount for area sampling Includes • Buck BioSlide™ pump • Calibration rotameter assembly (APB-706100) • Standard smart 120V charger • User manual Part Number

Description

Flow Rate (Total)

Power Source

APB-707000

Buck BioSlide™ Pump Model B1020

10 - 20 LPM

120V

APB-108000

Durable Hard Plastic Carrying Case With Foam Insert

-

-

Buck Bio-Culture™ Biocontaminent Sampling Pump Features • Flow rate: 30 - 120 LPM • Holds 90 mm agar petri dish • 380 holes - 1 mm diameter • Timing routine of 1, 2, 5 & 10 minutes • Tripod mount to allow 90o sampling • Sampling head is easily sterilized with gas torch or autoclave • Four times the flow rate of an Anderson sampler Includes • Buck Bio-Culture™ pump • Pencil torch • Tripod

• Standard smart 120V charger • User manual • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

APB-708000

Buck Bio-Culture™ Pump, Model B30120

30 - 120 LPM

120V

APB-708500

Calibration Head For Buck Bio-Culture™ Pump

-

AIR SAMPLING

17


AIR SAMPLING 18

MicroflowTM α Microbiological Air Sampler This instrument has been developed for airborne biological contaminants sampling in order to access the level of biocontamination in critical places (ex: clean rooms, operating rooms, pharmaceutical production plants, food and cosmetic industries, water purification plants, landfills, etc.) and in normal working life situations and not (air conditioning and ventilation controls). MicroflowTM α allows a wide range of airborne bio-contaminant sampling by impacting on agar plates (60 mm + 2 mm contact plate or 90 mm + 2 mm petri dish). Features • Flow rate: 30 - 60 - 90 - 100 - 120 LPM • Used with: 60 + 2 mm contact plate (MicroflowTM α 60) 90 + 2 mm petri dish (MicroflowTM α 90/C) Both with contact plate and petri dish (MicroflowTM α 60-90/C) • NiMH rechargeable battery, without memory effect • Silent microprocessor controlled fan to ensure maximum reliability on the sampled air volume • Compensation airflow system (in compensated models) • Low battery control and alarm • Prompts in 5 languages: English, French, German, Spanish, Italian & functions are "step-by-step" visualized • Delay start •Total volume of sampled air programmable from 1 up to 2000 L, with 1 L steps •Manual sampling for air volumes greater than 2000 L

• Sequential sampling also as required by ISPESL guidelines • Storing and displayed up to 99 samplings, with record of progressive n number, date, hour, sampling volume or time, flow rate, type of sampling (manual, sequential, programmable) • USB port to download data to a PC (optional) • Calibration control function (with optional calibration kit) • Remote switch with infrared rays control • Vertical or horizontal sampling (90° and 180°) • Prepared for mounting on photographic tripod

Model

MicroflowTM α 60 Kit

MicroflowTM α 90/C Kit

MicroflowTM α 60-90/C Kit

Includes

• MicroflowTM α sampler • IR remote control • Pencil torch • Additional 60 mm aluminum sampling head • Base for sampler vertical positioning • Battery charger • Calibration report • Warranty card • User manual • Carrying case

• MicroflowTM α sampler • IR remote control • Pencil torch • Additional 90 mm aluminum sampling head • Base for sampler vertical positioning • Battery charger • Calibration report • Warranty card • User manual • Carrying case

• MicroflowTM α sampler • IR remote control • Pencil torch • 60 & 90 mm aluminum head assembly • Base for sampler vertical positioning • Battery charger • Calibration report • Warranty card • User manual • Carrying case

Part Number

Description

Flow Rate (Total)

Power Source

AQ-G.1004

MicroFlow™ α Kit 60 (For Use With Contact Plates 60 mm ± 2 mm)

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1004-SS

MicroFlow™ α Stainless Steel Kit 60 (For Use With Contact Plates 60 mm ± 2 mm)

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1015

MicroFlow™ α Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1015-SS

MicroFlow™ α Stainless Steel Kit 90/C (For Use With 90 mm ± 2 mm Petri Dish), With Flow Compensation

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1027

MicroFlow™ α Kit 60-90/C (For Use With 60 mm ± 2 mm Contact Plate & With 90 mm ± 2 mm Petri Dishes), With Flow Compensation

30 - 60 - 90 - 100 - 120 LPM

120V

AQ-G.1120

Digital Calibration Kit For MicroFlow™ α Includes: Digital Differential Pressure Meter, Fitting Tubes & Conversion Table

-

-

AQ-G.1117-A

USB Interface For Data Download To PC Includes: Data Transmission & Data Management Software (In Compliance With UNICHIM No.1962) (Note: Data download requires a structural modification. In case of later purchase, MicroFlow™ α must be returned to Aquaria S.R.L. for software installation.)

-

-

AQ-A.2004

3 ft. Master Type Stand

-

-

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Zefon® A6 Impactor The Zefon® A6 Impactor sampler is an exact replica of the popular Andersen N-6 single stage impactor. The Zefon® A6 impactor is an aluminum device consisting of a top inlet "cone", a sampling head impactor stage which contains 400 precision drilled holes and a base section, which holds the agar media. The sampler is held together by three spring clamps and sealed with two o-ring gaskets. When air is drawn through the sampler, multiple jets of air direct any airborne particles toward the surface of the agar collection media surface where the particles are impacted and collected. The agar collection media is then sent to a laboratory for analysis. Features • Flow rate: 28.3 LPM (1 ACFM) • Particle size cut point: 0.65 μm • Sampler size: 4.25" diameter, 2.87" height, 1.23 lbs weight

• Material: aircraft grade aluminum • Uses 100 mm x 15 mm petri dishes • Certifications: meets NIOSH method 0800 & 0801 requirements

Part Number

Description

Power Source

ZE-Z-A6

Zefon A6 Impactor Only

120V

ZE-ZHV00-A6-KIT

Zefon® A6 Impactor Kit

120V

ZE-Z-A6-CAL

Adapter For "In-Line" Impactor Calibration

ZE-ZA0043

Zefon Heavy Duty Tripod Stand For Zefon A6 Impactor

Inf Z

®

®

Includes • Zefon® A6 Impactor • Pump flow meter • 1/4" I.D. tubing • Tripod stand • Carrying case

®

-

When Using A Zefon® A6 Impactor

ne

Accurate results when using a Zefon® A6 Impactor depend on proper measurement of flow through the impactor inlet. This can be best measured using a bubble or dry piston flow calibrator traceable to NIST standard (such as a Bios Defender or Gilian® Gilibrator) set up with the Zefon® A6 impactor "in-line". To your impactor "in-line", be sure to order the Z-A6-CAL adapter, which fits over the impactor inlet and allows tubing to be connected to it.

A static conductive replica of the 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Zefon® 10 mm Static Conductive Nylon Cyclone The Zefon® 10 mm Conductive Nylon Cyclone (Sensidyne "Dorr-Oliver" style) is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM. 10 mm Nylon Cyclone Efficiency Curve Comparison at 1.7 lpm

Collection Efficiency (%)

Features • Flow rate: ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm Other applications: 2 LPM with a nominal particle diameter of 3.5 μm • Conductive, eliminates any possible bias in sampling results from static charging • Lightweight design only 3.6 oz for the complete assembly including cassette and holder • Certifications: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust

Zefon 10 mm Heavy Duty Sensidyne TSI Zefon 10 mm Conductive

Particle Size (µ) Source: Internal Zefon performance tests with all 4 cyclones under identical conditions

Part Number

Description

ZE-ZA0080

Zefon® 10 mm Conductive Nylon Cyclone

ZE-ZA0081

Zefon® 10 mm Conductive Nylon Cyclone With Cassette/Cyclone Holder

ZE-ZA0063

Zefon® 1 Liter Cyclone Calibration Jar For Aluminum Cyclone & Zefon® Conductive Nylon Cyclone

ZE-ZA0085

Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones)

ZE-ZA0061

Zefon® Universal Cassette/Cyclone Holder Only

ZE-ZA0082

Replacement Grit Pots, 25/Pack

The cyclone must be used in conjuction with a cassette/cyclone holder. Compatible with both the Zefon® cassette/cyclone holder ZE-ZA0061 or the SKC holder SK-225-1.

AIR SAMPLING

19


AIR SAMPLING

10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone Sampler For Respirable Dust & Silica The "Dorr-Oliver" 10 mm Nylon Cyclone is used in conjunction with 37 mm filter cassettes to separate dust particles by size with the respirable particles being collected on the filter and larger particles being removed. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm when operated at a flow rate of 1.7 LPM. Features • Flow rate: ISO/ACGIH/CEN convention: 1.7 LPM with a nominal particle diameter of 4.0 μm Other applications: 2 LPM with a nominal particle diameter of 3.5 μm • Certification: meets NIOSH requirements for 10 mm nylon cyclones as specified in 0600 for nuisance dust & 7500, 7501, 7601 & 7602 for silica dust Part Number

Description

GIL-800061

10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

GIL-7013376

Cyclone Calibration Jar For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone & Inhalable Dust Sampler Head

GIL-200159

Replacement Cyclone Grit Pot For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

GIL-801124

Replacement Cylcone Vortex Finder Accessory For 10 mm Sensidyne "Dorr-Oliver" Nylon Cyclone

Inf Z

Cyclone Calibration Jar

ne

When ordering a traditional Sensisyne "Dorr-Oliver" cyclone sampler, be sure to also order a Cyclone Calibration Jar GIL-7013376. Since a Sensidyne "Dorr-Oliver" cyclone has only a single hose connection, this jar allows proper placement of the cyclone filter between the sampling pump and the calibrator device.

A replica of the SKC Aluminum Cyclone Zefon® Aluminum Cyclone For Respirable Dust The Zefon® Respirable Dust Aluminum Cyclone is used in conjunction with 25 mm or 37 mm 3-piece filter cassettes to separate and remove larger particles from the respirable particles collected on the cassette’s filter. The collection efficiency curve meets the standards set forth by ACGIH/ISO/CEN for a respirable curve with a median 50% cut point of 4 μm at 2.5 LPM flowrate. A cyclone holder and 25 mm or 37 mm 3-piece filter cassette are required for use of the Zefon® Aluminum Cyclone. Features • Aluminum construction is static conductive, eliminating interference • Lightweight design only 1.1 oz • Fully interchangeable with SKC Aluminum Cyclone • Certification: specified in NIOSH method 0600 for respirable particulates & NIOSH 7500 for silica, crystalline

20

Part Number

Description

ZE-ZA0060

Zefon® 37 mm Aluminum Cyclone For Respirable Dust

ZE-ZA0075

Zefon® 25 mm Aluminum Cyclone For Respirable Dust

ZE-ZA0062

Zefon® 37 mm Aluminum Cyclone For Respirable Dust With Holder

ZE-ZA0076

Zefon® 25 mm Aluminum Cyclone For Respirable Dust With Holder

ZE-ZA0063

Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone

ZE-ZA0085

Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne "Dorr-Oliver" Nylon Cyclones

ZE-ZA0061

Zefon® Universal Cassette/Cyclone Holder Only

ZE-ZA0066

Replacement Grit Pots For Aluminum Cyclone, 25/Pack

ZE-ZA0067

Replacement O-Rings For Aluminum Cyclone, 5/Pack

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Shown with cassette installed in holder


AIR SAMPLING

Zefon® Aluminum Cyclone Calibration Adapter A chamber specifically designed to fit over the Zefon® Aluminum Cyclone and connect 1/4" I.D. tubing for flow calibration. This provides the best calibration option by taking an actual measurement as close to the cyclone inlet as possible. Chamber fits both Zefon® brand and SKC brand 37 mm and 25 mm aluminum cyclones. Part Number

Description

ZE-ZA0011

Zefon® Aluminum Cyclone Calibration Adapter

Zefon® Calibration Jar The Zefon® Cyclone Calibration Jar is a container with all the proper fittings and connections to calibrate personal sampling pumps with the Zefon®, SKC, or Sensidyne "Dorr-Oliver" Cyclones and inhalable dust samplers. Part Number

Description

ZE-ZA0063

Zefon® 1 Liter Cyclone Calibration Jar For Zefon® Conductive Nylon Cyclone & Aluminum Cyclone

ZE-ZA0085

Zefon® 2 Liter Cyclone Calibration Jar For Zefon® & Sensidyne “Dorr-Oliver” Nylon Cyclones

Zefon® Bio-Tape™ - Standardized Method For Surface Sampling Zefon® Bio-Tape™ provides a standardized surface sampling method used for the determination of possible microbial, bioaerosol, and inorganic dust contamination. It provides the ability to quickly take a sample and measure the relative degree of contamination. It is especially useful when sampling valuable or non-transportable materials and is very effective on smooth areas of concern. Features • Provides sample consistency • Individually serialized for traceability • Prevents cross contamination • Eliminates problems of placing tape in a zip bag, or broken glass slides • Samples may be archived by the laboratory for later review • Requires less laboratory prep time

Part Number

Description

ZE-BT0025

Zefon®Bio-Tape™ Slides, 25/Box

ZE-BT0050

Zefon®Bio-Tape™ Slides, 50/Box

ZE-BT0500

Zefon®Bio-Tape™ Slides, 500/Box

* Limited shelf life

Zefon®Sterile Surface Swabs Zefon® Sterile Surface Swabs are an easy way to sample suspect areas for mold contamination. Simply swab the suspect area and submit to a laboratory where the sample will be cultured and the type of mold identified. Each swab comes in an easy to use container for sampling, transport and storage. Part Number

Description

ZE-ZA0020

Mold Swab Kit

ZE-ZA0023

Mold Swabs Only, 50/Box

Includes • (10) Swabs • (10) Sterile 10 cm x 5 cm templates

* Limited shelf life

3M™ LeadCheck™ Swabs 3M™ LeadCheck™ Swabs provide an easy solution for lead detection. Easy to use, disposable 3M LeadCheck swabs will work on any surface, instantly turning bright pink when lead is present. 3M LeadCheck swabs are odorless, disposable, and non-staining. Part Number

Description

LC8S10C

3M™ LeadCheck™ Swabs, 8/Pack

Features • Detects lead on most surfaces within 30 seconds • Simple to use: just crush, shake and swab. RED MEANS LEAD™! • Disposable, no-mess swabs are easy, clean and contained • Test confirmation card to verify results in every kit AIR SAMPLING

21


AIR SAMPLING

Zefon® Preloaded Air Sampling Filter Cassettes Zefon® offers a complete line of air sampling cassettes manufactured to meet all applicable NIOSH, OSHA, and EPA standards. All cassette housings are manufactured in-house from polystyrene or polypropylene and are available in two or three piece configurations. Cassettes are individually assembled and preloaded under stringent quality assurance standards with only the finest quality membrane and support pads. Features • Fully assembled, preloaded and ready to use • Leak free construction eliminates sample loss • Configurations available to conform with most NIOSH standards that require filter cassettes • Wide selection of filter membrane types • Available with Zefon® Solu-Sert™ or Gravi-Sert™ filter capsules installed • Sterile models available for fluid contamination sampling and microbiological analysis • Ultra Pure PTFE models available for pharmaceutical compound sampling • Custom configurations available

PVC Preloaded Filter Cassettes Part Number

Diameter

Pore Size

Housing Style

Notes

Quantity

ZE-525PVC

25 mm

5.0 μm

2-Piece, Styrene

50/Box

ZE-5M52P

25 mm

5.0 μm

2-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-5P52P

25 mm

5.0 μm

2-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

ZE-535PVC

25 mm

5.0 μm

3-Piece, Styrene

50/Box

ZE-5M53P

25 mm

5.0 μm

3-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-5P53P

25 mm

5.0 μm

3-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

ZE-725PVC

37 mm

5.0 μm

2-Piece, Styrene

50/Box

ZE-7M52P

37 mm

5.0 μm

2-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-7P52P

37 mm

5.0 μm

2-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

ZE-735PVC

37 mm

5.0 μm

3-Piece, Styrene

50/Box

ZE-7M53P

37 mm

5.0 μm

3-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-7P53P

37 mm

5.0 μm

3-Piece, Styrene, Banded

Pre-Weighed Filter

50/Box

*Limited shelf life

MCE Preloaded Filter Cassettes Part Number

Diameter

Pore Size

Housing Style

Notes

Quantity

ZE-528MCE

25 mm

0.8 μm

2-Piece, Styrene

50/Box

ZE-538MCE

25 mm

0.8 μm

3-Piece, Styrene

50/Box

ZE-7345MCE

37 mm

0.45 μm

3-Piece, Styrene

50/Box

ZE-PS7345MCE

37 mm

0.45 μm

3-Piece, Styrene

Sterile

50/Box

ZE-734MCECF

37 mm

0.45 μm

3-Piece, Conductive

50/Box

ZE-7345MCECF

37 mm

0.45 μm + 5.0 μm

3-Piece, Conductive

50/Box

ZE-7445MCE-C

37 mm

0.45 μm

4-Piece, Styrene

Filter Placed Between Spacer Rings

50/Box

ZE-7445MCECF-C

37 mm

0.45 μm

4-Piece, Conductive

Filter Placed Between Spacer Rings

50/Box

ZE-728MCE

37 mm

0.8 μm

2-Piece, Styrene

50/Box

ZE-729MCE

37 mm

0.8 μm

2-Piece, Styrene, Banded

50/Box

ZE-7M92M

37 mm

0.8 μm

2-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-738MCE

37 mm

0.8 μm

3-Piece, Styrene

50/Box

ZE-PS738MCE

37 mm

0.8 μm

3-Piece, Styrene

Sterile

50/Box

ZE-738MCECF

37 mm

0.8 μm

3-Piece, Conductive

50/Box

ZE-739MCE

37 mm

0.8 μm

3-Piece, Styrene, Banded

50/Box

ZE-7M93M

37 mm

0.8 μm

3-Piece, Styrene, Banded

Match-Weighed Filters

50/Box

ZE-7M93M-SB

37 mm

0.8 μm

3-Piece, Styrene, Banded

Match-Weighed Filters With Security Band

50/Box

*Limited shelf life

22

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® pre-weighed cassettes eliminate the inconvenience of pre-weighing filters by providing the filter weight on each cassette prior to sampling. Features • Each cassette is labeled with weight and serial number • Use of pure homopolymer PVC filters provides excellent weight stability • PVC filters specially designed with no silica and low ash properties Part Number

Diameter

Pore Size

Housing Style

Weight Tolerance

Quantity

ZE-5P52P

25 mm

5.0 μm

2-Piece Styrene

15 μg

50/Box

ZE-5P52P-GS

25 mm

5.0 μm Gravi-Sert™

2-Piece Styrene

15 μg

50/Box

ZE-5P53P

25 mm

5.0 μm

3-Piece Styrene

15 μg

50/Box

ZE-7P52P

37 mm

5.0 μm

2-Piece Styrene

15 μg

50/Box

ZE-7P53P

37 mm

5.0 μm

3-Piece Styrene

15 μg

50/Box

AIR SAMPLING

Gravimetric Pre-Weighed Cassettes

*Limited shelf life

Using A Pre-Weighed Cassette

Inf Z

ne

Using A Match-Weight Cassette

Environmental conditions can have a significant effect on filter weight readings. When using Zefon® pre-weighed cassettes, it is important that the post sample weighing is performed under the same environmental conditions used at the Zefon® factory. Those conditions are set at a temperature of 68°F and a relative humidity of 50%. Using Zefon® pre-weighed cassettes does not comply with OSHA directives which require both the "tare weight" and "secondary weight" to be performed on the same microbalance and environmental conditions. If complying with this directive is a concern, match-weighed cassettes are a good alternative way to save time and still comply with the directive.

The weight tolerance of match weighed filters references the maximum difference in weight from the test (top) filter and the control (bottom) filter. A stated tolerance of 50 μg means that the control filter may differ in weight no more than 50 μg from the test filter. This is important to know during post sample weighing as the weight tolerance of the 2 filters needs to be considered when calculating results.

Matched-Weighed Configuration

During manufacture, filters with matched weights (within the given tolerance) are inserted into the cassette in random order. Thus, it is possible for the control filter to weigh more than the test filter before sampling (within the given tolerance). If the control filter still weighs more after sampling, a sample likely was not collected. Please check your equipment for proper operation and pump flow.

Gravimetric Match-Weighed Cassettes Gravimetric analysis samples require filters to be weighed both before and after sampling to determine the amount of contaminate collected. Zefon® matchweighed cassettes eliminate the need of weighing filters before sampling by providing two filters which are matched in weight. The top filter collects particulate and the bottom filter serves as a control. After sampling, both filters are weighed and the difference in weight equals the amount of contaminate collected.

Features • Each cassette labeled with serial number • Color coded to indicate filter type • Preloaded - ready to use

Part Number

Filter

Diameter

Pore Size

Housing Style

Band Color

Weight Tolerance

Quantity

ZE-5M92M

MCE

25 mm

0.8 μm

2-Piece Styrene

Blue

50 μg

50/Box

ZE-5M93M

MCE

25 mm

0.8 μm

3-Piece Styrene

Blue

50 μg

50/Box

ZE-7M92M

MCE

37 mm

0.8 μm

2-Piece Styrene

Blue

50 μg

50/Box

ZE-7M92M-R-SB

MCE

37 mm

0.8 μm

2-Piece Styrene

Blue With Security Band

50 μg

50/Box

ZE-7M92M-TN

MCE

37 mm

0.8 μm

2-Piece Tenite, Meets Requirement Of ASTM D2276

None

50 μg

50/Box

ZE-7M93M

MCE

37 mm

0.8 μm

3-Piece Styrene

Blue

50 μg

50/Box

ZE-5M52P

PVC

25 mm

5.0 μm

2-Piece Styrene

Red

20 μg

50/Box

ZE-5M53P

PVC

25 mm

5.0 μm

3-Piece Styrene

Red

20 μg

50/Box

ZE-7M52P

PVC

37 mm

5.0 μm

2-Piece Styrene

Red

20 μg

50/Box

ZE-7M53P

PVC

37 mm

5.0 μm

3-Piece Styrene

Red

20 μg

50/Box

*Limited shelf life

AIR SAMPLING

23


AIR SAMPLING

Zefon® 25 mm MCE Preloaded Filter Asbestos Sampling Cassettes Zefon® and EMS offer PCM 25 mm conductive air sampling cassettes designed and manufactured to meet all applicable NIOSH, AHERA, OSHA, and EPA standards. The cassette housings are manufactured in-house from high quality polypropylene and are individually assembled and preloaded under stringent quality control standards. Features • 2" conductive extension cowl • 3-piece housing • Meets regulatory requirements • Each cassette comes with a unique serial number Part Number

Diameter

Pore Size

Housing Style

Notes

Quantity

ZE-Z008BA

25 mm

0.8 μm

3-Piece With 2" Conductive Cowl

Asbestos PCM, Banded

50/Box

EMS-900103

25 mm

0.8 μm

3-Piece With 2" Conductive Cowl

Asbestos PCM, Banded

50/Box

*Limited shelf life

Zefon® Air-O-Cell® Bioaerosol Cassettes The Zefon® Air-O-Cell® is a unique sampling cassette designed for the rapid collection of a wide range of both viable and non-viable aero-allergens including mold spores, pollen, insect parts, skin cells, fibers and inorganic particulate. These cassettes can be used with any standard off-the-shelf sampling pump capable of drawing 15 LPM open flow, including the Zefon® Bio-Pump® Plus, a convenient battery powered hand-held pump for ease of sampling. Air flow into cassette

Features • Industry proven & accepted • Independently validated • Laboratory preferred, easy to analyze • Proven results • No sample loss during shipping & handling • Pre-loaded, no slides to prepare

Alternaria

Pine pollen

Stachybotrys Skin cells

Dustmite

Exit orifice

Part Number

Description

Quantity

ZE-AOC050

Air-O-Cell® Air Sampling Cassettes

50/Box

ZE-AOCCAL

Air-O-Cell In-Line Calibration Adapter

Each

ZE-AOC-WS10

Air-O-Cell® Inner Wall Samplers

10/Pack

ZE-AOCWS10-KIT

Air-O-Cell® Inner Wall Sampler Kit

10/Pack & A Plunger Rod

®

*Limited shelf life

Inf Z 24

Inner Wall Sampling Attachments

ne

Zefon® Inner Wall Attachments are used in conjunction with Air-O-Cell®, MoldSNAP™, or Via-Cell® cassettes to non-destructively access microbial contamination in a wall cavity, equipment for proper operation and pump flow. To use, simply drill a 3/8" hole (preferably by hand), connect the tubing attachment to the cassette and insert the tube into the wall.

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Allergenco-D IAQ Air Sampling Cassettes The Allergenco-D disposable IAQ air sampling cassette was developed for the sampling and collection of aeroallergens and bioaerosols for quantitative analysis of mold spores, pollen, skin fragments, insects, combustion particles, toners, environmental dusts, construction dusts, and other airborne particulates. These cassettes employ a patented laminar flow venturi which provides higher readable collection efficiency than other IAQ cassettes as well as a more well defined impaction trace, helping to reduce analysis time. Features • Assembled under HEPA hoods • Laminar flow venturi allows for the most uniform slit deposit in the industry • Patented design • Higher collection efficiency than other IAQ slit impactor cassettes • Barcoded for easy tracking • Inner wall sampling attachments available • No luer adapters necessary - tubing fits directly onto cassette • Compatible with all portable IAQ pumps designed to fit competitors cassettes

Part Number

Description

Quantity

EMS-120515

Allergenco-D Air Sampling Cassettes

50/Box

EMS-120518

Allergenco-D Inner Wall Samplers

10/Pack

*Limited shelf life *Don’t forget to request your FREE Allergenco-D inner wall samplers with the purchase of a box of cassettes part # EMS-120518

The most uniform slit sample trace in the industry! Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes The Allergenco-D Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK). Features • Superior collection efficiency - aerodynamic diameter cutoff = D50 = ~1.7 μm • Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace • Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing • Generous area on the cassette label for field notes such as sample location, dates and time • Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive • Designed to stack cassettes for easy storage and use Part Number

Description

Quantity

EMS-120520

Allergenco-D Posi-Track Full Slide Indoor Air Quality Impactor Cassettes

24/Box

*Limited shelf life

Cyclex-D Air Sampling Cassettes Utilizing a 360o impaction chamber, the Cyclex-D was pioneered to evenly and quantitatively collect aeroallergens. With a flow rate of 20 LPM the capture and actual collection efficiency of the Cyclex-D exceeded 50% at d50 = 1 μm compared to the industry norm of 2.5 μm. Part Number

Description

Quantity

EMS-120135

Cyclex-D Air Sampling Cassettes

50/Box

EMS-120138

Cyclex-D Inner Wall Samplers

10/Pack

*Limited shelf life *Don’t forget to request your FREE Cyclex-D inner wall samplers with the purchase of a box of cassettes part # EMS-120138-FREE

Need help choosing between the Zefon® High Volume Diaphragm Area Sampling Pump and the Zefon® High Volume Rotary Vane Sampling Pump? Don’t worry ERE Inc.TM is here for you

1-888-287-3732 Please refer to page 11 for more information.

AIR SAMPLING

25


AIR SAMPLING

Micro5 MicroCell IAQ Air Sampling Cassettes Utilizing a 360o impaction chamber, the Micro5 was pioneered to evenly & quantitatively collect aeroallergens such as pollens, mold & fungal spores, fibers, danders, insect components and other air-borne contaminants. Features • Exceptionally uniform collection trace • Virtually 100% accurate for the entire fungal spore range • Designed to operate at a flow rate of 5 LPM to ensure optimal collection efficiency Part Number

Description

Quantity

EMS-120170

Micro5 Air Sampling Cassettes

50/Box

EMS-120138-M5

Micro5 Inner Wall Samplers

10/Pack

*Limited shelf life *Don’t forget to request your FREE Micro5 inner wall samplers with the purchase of a box of cassettes part # EMS-120138-M5

The most uniform slit sample trace in the industry! Micro5 Posi-Track Full Slide Indoor Air Quality Impactor Cassettes The Micro5 Posi-Track full slide cassette collects mold spores, pollen, skin cells, dust, combustion particles, etc. on a standard 1" x 3" microscope slide printed with a unique barcoded serial number (POSI-TRACK).

Part Number

Description

EMS-120171

Micro5 Posi-Track Full Slide Indoor Air Quality 24/Box Impactor Cassettes

Quantity

*Limited shelf life

Features • Superior collection efficiency - aerodynamic diameter cutoff = D50 = ~1.7 μm • Patented laminar flow venturi design provides higher readable collection efficiency as well as a more well defined impaction trace • Universal fittings allow the connection to a vacuum source with either a 1/2" to 1/4" converter or directly to a 1/4" I.D. tubing • Generous area on the cassette label for field notes such as sample location, dates and time • Minimizes handling and mounting of sample traces for microscopic particle counting • Barcoded serial number (POSI-TRACK) on the slide follows the sample from field sampling, through laboratory analysis and sample archive • Barcoded serial number (POSI-TRACK) allow for automated input of sample numbers into laboratory software (LIMS) and chain-of custody forms • Deposition of particles/spores onto the adhesive is very uniform due to the design of the laminar flow venturi within the spore trap • Designed to stack cassettes for easy storage and use

Zefon® Via-Cell® Bioaerosol Sampling Cassettes The Zefon® Via-Cell® bioaerosol sampling cassette is designed to collect both viable and non-viable bioaerosols, maintain viability of the viable mold spores and prevent growth during transport to the laboratory. Simply connect it to any pump calibrated to 15 LPM and run your sample. The key to the Via-Cell® is that the media used for collection maintains viability of spores and allows several analysis options.

One Sample, Multiple Analysis Options Culturable Sampling The Zefon® Via-Cell® sampler is the perfect tool for collecting viable organisms and culturing them on agar plates. Simply dilute the media in sterile water and transfer to a culture plate. PCR Analysis The Zefon® Via-Cell® utilizes a water soluble collection media which is ideal for PCR and other chemical types of analysis. Once the sample is diluted in water, it can be transferred most anywhere. Direct Microscopy Samples collected using the Zefon® Via-Cell® sampler may be "pre-screened" using direct microscopy methods, which allows the analyst to decide if additional analysis techniques are needed, which may include culturing or standard direct microscopy analysis. Part Number

Description

Quantity

ZE-VIA010

Via-Cell Air Sampling Cassettes

10/Box

®

*Limited shelf life

26

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR SAMPLING

Zefon® Gemini® Twin Port Sorbent Tube Sampler The Zefon® Gemini® Twin-Port Sorbent Tube Sampler can be used with the Zefon® Escort ELF®, or just about any other sampling pump able to pull a flow rate of 1.5 LPM at 25" of water backpressure. It offers increased flexibility and control in gathering samples through sorbent tubes. If air is being sampled for two or more contaminants, the Gemini can draw samples at independent flow rates through tubes containing different sorbents. In situations where a single contaminant is being sampled, sampling on two tubes of the same type can be done simultaneously at different flow rates. This type of sampling protects against breakthrough which occurs when a tube’s sampling capacity is exceeded because the concentration of a contaminant is higher than anticipated. Duplicate sampling at the same flow rate can also be done to achieve better results. Features • Valved mechanism allows flow control down to 0.001 LPM • Control the flow rate of each port independently • Includes tube covers to fit both large and small tube sizes Part Number

Description

ZE-497697

Zefon® Gemini® Twin Port Sampling Kit

Includes • Zefon® Gemini Twin-Port Sorbent Tube sampler • Tube protectors • Y-connectors • Clips • Carrying case

Zefon® Sorbent Tubes Zefon® Sorbent Tubes are high quality glass tubes that are packed with accurately weighed, high-purity sorbents. They are designed to adsorb vapors and gases passed over them when used with low flow sampling pumps and fit a variety of tube holders, including the Zefon® Gemini® Twin Port Sorbent Tube Sampler. Many Zefon® sorbent tubes are divided into sections, with two absorbent sections being most common. The first section is twice the size of the back section and collects the compounds of interest. The second section is a backup section to determine if airborne contaminants breakthrough occurred on the front section. Features • Highest sorbent material purity for contamination-free samples • Accurate sorbent weight for uniform testing results • Uniform pressure drop to assure repeatable sampling results • Designed to comply with all NIOSH specifications for tube dimensions, sorbent quality, particle size, divider composition and pore size Part Number

Sorbent

Size (O.D. x L)

Sections

Sorbent

Tube Ends

Separator*

SKC Equivalent

Quantity

ZE-ZST-001

Coconut Charcoal

6 mm x 70 mm

2

100 mg / 50 mg

GS

F/F/W

226-01

50/Box

ZE-ZST-001B

Coconut Charcoal

6 mm x 70 mm

2

100 mg / 50 mg

GS

F/F/W

226-01B

1000/Box

ZE-ZST-002

Coconut Charcoal

8 mm x 110 mm

2

400 mg / 200 mg

GS

F/F/W

226-09

50/Box

ZE-ZST-002B

Coconut Charcoal

8 mm x 110 mm

2

400 mg / 200 mg

GS

F/F/W

226-09B

1000/Box

ZE-ZST-003

Coconut Charcoal

10 mm x 110 mm

2

800 mg / 200 mg

GS

F/W/W

226-16

50/Box

ZE-ZST-020

Chromosorb

8 mm x 110 mm

2

100 mg / 50 mg

GS

W/W/W

226-107

50/Box

ZE-ZST-040

Microlite*

6 mm X 70 mm

1

200 mg

GS

W/W

226-17-1A

50/Box

ZE-ZST-050

Silica Gel

6 mm X 70 mm

2

150 mg / 75 mg

GS

F/W/W

226-10

50/Box

ZE-ZST-051

Silica Gel

6 mm X 70 mm

2

100 mg / 50 mg

GS

F/W/W

226-51

50/Box

ZE-ZST-054

Silica Gel

8 mm x 110 mm

2

520 mg / 360 mg

GS

W/W/W

226-10-04

50/Box

ZE-ZST-058

Silica Gel

10 mm X 110 mm

2

1040 mg / 260 mg

GS

F/W/W

226-22

50/Box

ZE-ZST-060

Silica Gel (specially cleaned)

7 mm X 110 mm

2

400 mg / 200 mg

GS

W/W/G/W

226-10-03

50/Box

ZE-ZST-080

XAD-2

8 mm x 110 mm

2

100 mg / 50 mg

GS

W/W/W

226-30-04

50/Box

ZE-ZST-090

XAD-7

6 mm X 110 mm

2

100 mg / 50 mg

GS

W/W/W

226-95

50/Box

* Microlite sorbent is equivalent to Hydrar, Carulite, and the SKC Anasorb C300.

Tube Ends Separator Codes GS: Glass sealed W: Glass Wool GO: Glass open G: Glass Fiber Filter F: Polyurethane Foam

AIR SAMPLING

27


AIR SAMPLING

Personal Pump Accessories

ZE-456226

CY-8860-4335

ZE-ZA0005

ZE-ZA0061

ZE-ZA0046

ZE-ZA0010

ZE-459743 10 mm O.D. x 220mm L

10 mm O.D. x 150 mm L 8 mm O.D. x 110 mm L 6 mm O.D. x 70 mm L

GIL-7015377P

Sample Tubing

APB-109030

Part Number

Description

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

ZE-456226

3/8'' O.D. x 1/4'' I.D. x 36" Long PVC Tubing With Tube Clip

Tube Covers

Cassette Accessories Part Number

Description

ZE-ZA0046

Cassette Opener For 25 mm, 37 mm & Air-O-Cell® Cassettes

ZE-ZA0049

Cassette Opener For 47 mm & Air-O-Cell® Cassettes

ZE-ZA0061

Universal Cassette/Cyclone Holder, Each

ZE-ZA0005

Plastic Luer Adapters, 10/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-459743

Metal Luer Adapters, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-ZA0010

25 mm Conductive Filter Transport Case

Buck Low Flow Sorbent Tube Holders Available both with and without flow adjustment. Use non-adjustable when using a sampling pump designed specifically for low flow sampling without adapters. Use adjustable flow to use with standard sampling pumps in constant pressure mode. Tube holder comes setup for 6 mm x 70 mm tubes. Additional size tube covers maybe purchased separately. Sorbent Tube Accessories

28

Part Number

Description

GIL-7015377P

Tube Tip Breaker, 5/Pack

APB-109032

Single Tube Holder With Non-Adjustable Flow

APB-109030

Single Tube Holder With Adjustable Flow (5 - 800 cc/min)

APB-109033

Single Tube Holder With Adjustable Flow (5 - 100 cc/min)

APB-109022

6 mm O.D. x 70 mm L Tube Cover

APB-109024

8 mm O.D. x 110 mm L Tube Cover

APB-109026

10 mm O.D. x 150 mm L Tube Cover

APB-109028

10 mm O.D. x 220 mm L Tube Cover

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


ZE-03113

AIR SAMPLING

Area Pump Replacement Parts

ZE-03180

ZE-03200

ZE-03184

ZE-03179

For Zefon® High Volume Diaphragm Area Sampling Pump Part Number

Description

ZE-03113

1/8" Air Flow Regulator Valve

ZE-03180

1/8" To 1/4" Conversion Fitting

ZE-03200

1/4" Hose Barb

ZE-03184

Rubber Foot For Diaphragm Pumps

ZE-03179

Muffler For Diaphragm Pump

ZE-03113

ZE-03200

ZE-03201

ZE-9800-52

ZE-ZGHV01

ZE-AA928

For Zefon® High Volume Rotary Vane Sampling Pump Part Number

Description

ZE-03113

1/8" Air Flow Regulator Valve

ZE-03200

1/4" Hose Barb

ZE-03201

Rubber Foot For ZE-ZHV00 Pump

ZE-AL-9800-52

Exhaust Filter For ZE-ZHV00 Pump

ZE-ZGHV01

Glass Muffler Jar For ZE-ZHV00 Pump

ZE-AA928

Felt Filters For ZE-ZHV00 Pump

Area Pump Accessories

EMS-200550

CY-8860-4335

Part Number

Description

EMS-200550

Premium Telescopic Sampling Tripod Stand

CY-8860-4335

3/8'' O.D. x 1/4'' I.D. Clearflex 60 Non-Phtalate PVC Tubing, 100 ft

ZE-ZA0005

Plastic Luer Adapter, 10/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-459743

Metal Luer Adapter, 3/Pack (Attaches Cassette to 1/4" I.D. Tubing)

ZE-ZA0005

ZE-459743

AIR SAMPLING

29


AIR SAMPLING

Air Sampling Bag Selection Guide

Choosing The Best Film For Your Gas Sampling Bag Needs Properties

30

Advantages

Limitations

Tedlar®

• Low gas permeation • High tensile strength • Max. operating temp: 400°F • Unaffected by the chemical components of gases commonly sampled

• Less permeable than FEP, PFA and TFM • Bags resist puncture in the field • Less expensive than FEP, PFA, TFM film

• Exhibits background levels of DMAC and phenol • High permeation rate for CO2 • Relatively high permeation rate for O2

ALTEF

• Developed specifically for gas sampling applications • Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols • Max. operating temp: 260°F • Made of 0.003" thick film

• Suitable for sampling most VOC's and many sulfur compounds • Low VOC background • Longer sample storage times than most other bag materials • Does not exhibit background levels of DMAC or phenol • Lower permeability than Tedlar® to CO2, N2, and CH4 • Superior resistance to solvents

• More permeable to most compounds than Tedlar® • Not suitable for sampling ketones and esters in high concentrations (>30%) • Less resistance to UV light than Tedlar® • Many sulfur compounds must be analyzed within 24 hours. • More expensive than Tedlar®

Multi-layer Foil

• Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2 • Foil layers provide very low permeability and complete moisture barrier • Max. operating temp: 190°F • Opaqueness protects samples from ultraviolet light

• The only bag material that adequately holds H2S for long periods • Ideal for collecting low molecular weight compounds • Sample stability up to 5 days for most compounds • Very low permeability to O2 and CO2 • Good VOC stability • Less expensive than Tedlar® and ALTEF

• Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials • Recommend analyzing within 48 hours after collection for CH4, H2S, CO, and CO2

FEP

• One of the most chemically inert materials available for making gas sampling bags • Max operating temperature: 400°F • Virtually transparent

• Works well in extreme temperatures from -400°F to 400°F • Heavier gauge film is resistant to most severe corrosives as well as tolerates applications involving rough handling or difficult service conditions • Less expensive than PFA

• Poor long term storage stability for most VOC's and sulfur compounds • Much more permeable and more expensive than Tedlar®, ALTEF, and MultiLayer Foil bags • Lower tensile strength than Tedlar®

PFA

• Highest purity, most chemically inert film available for making gas sampling bags • Wide temp range -420°F to 500°F

• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids • Temps from –400°F to 500°F

• Poor long term storage stability for most VOC's and sulfur compounds • The most expensive film option for gas sampling bags • Much more permeable than Tedlar®

TFM

• High purity, flexible, low permeation versus FEP and PFA • Translucent • Wide temperature range; from –328°F to 500°F

• Not affected by the most corrosive chemicals, such as HF, Nitric, HCL and Sulfuric Acids • Sample stability for 4 to 5 days for most compounds • Withstands temperatures from –400°F to 500°F

• Expensive • Tears easily • Low tensile strength • More permeable than Tedlar®, ALTEF, and Multi-Layer foil bags

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Polypropylene Screw Cap Combo Valve with Replaceable Septum

Polypropylene Locking Combo Vakve with Septum

Nickel Plated HR Barbed On/Off Valve

Stainless Steel TCLP Fitting with Replaceable Septum

Stainless Steel Push/Pull Valve

Plastic Jaco Plating for Tubing or Septum

PFA Fitting Tubing or Septum

AIR SAMPLING

Valves And Fittings For Gas Sampling Bags

Swagelok Type Stainless Steel Fitting for Tubing or Septum

PTFE On/Off Valve with Stopcock

Valves and Fittings

Features

Polypropylene Screw Cap Combo Valve With Replaceable Septum

• On/Off valve function with replaceable septum in a single unit • Made of Inert polypropylene • Quick turning screw cap to open and close valve • Visual confirmation that valve is open or closed

Polypropylene Locking® Combo Valve With Septum

• On/Off valve function with septum in a single unit • Made of Inert polypropylene • Push/Pull (On/Off) valve stem • Quick Locking function, in closed position Fluoropolymer faced septum, with Ultra-low bleed silicone

Stainless Steel TCLP Fitting With Replaceable Septum

• Stainless steel body construction with aluminum cap • Designed for use with Zero Headspace Extractors • Replaceable fluoropolymer faced septum

Swagelok® Type Stainless Steel Fitting For Tubing Or Septum

• Stainless steel construction • Option of cap for tubing or septum • Replaceable fluoropolymer faced septum with large area

Nickel Plated Halkey® Roberts Barbed On/Off Valve

• Barbed stem for attaching tubing • Leak resistant seal in closed position

Plastic Jaco® Fitting For Tubing Or Septum

• Compression ferrule secures tubing onto fitting • Polypropylene molded construction • Option of cap for tubing, or cap with septum • Replaceable fluoropolymer faced septum with large area

PFA Fitting For Tubing Or Septum

• PFA fluoropolymer construction • Option of cap for tubing, or cap with septum • Compression ferrule secures tubing onto fitting • Replaceable fluoropolymer faced septum with large area

Tedlar® Gas Sampling Bag With Screw Cap Combo Valve With Replaceable Septum Part Number

Capacity

Size

Stem O.D.

Quantity

Part Number

Capacity

Size

Stem O.D.

Quantity

JIP-GSTP00-0606NSG1B

0.6 Liter

6" x 6"

3/16"

10/Pack

JIP-GSTP12-1221NSG1B

12 Liter

12" x 21"

3/16"

10/Pack

JIP-GSTP010707NSG1B

1 Liter

7" x 7"

3/16"

10/Pack

JIP-GSTP16-1818NSG1B

16 Liter

18" x 18"

3/16"

10/Pack

JIP-GSTP00-0610NSG1B

1.2 Liter

6" x 6"

3/16"

10/Pack

JIP-GSTP25-1824NSG1B

25 Liter

18" x 24"

3/16"

10/Pack

JIP-GSTP02-0909NSG1B

2 Liter

9" x 9"

3/16"

10/Pack

JIP-GSTP40-2424NSG1B

40 Liter

24" x 24"

3/16"

10/Pack

JIP-GSTP03-1010NSG1B

3 Liter

10" x 10"

3/16"

10/Pack

JIP-GSTP56-2430NSG1B

56 Liter

24" x 30"

3/16"

10/Pack

JIP-GSTP05-1212NSG1B

5 Liter

12" x 12"

3/16"

10/Pack

JIP-GSTP73-2436NSG1B

73 Liter

24" x 36"

3/16"

10/Pack

JIP-GSTP07-1215NSG1B

7 Liter

12" x 15"

3/16"

10/Pack

JIP-GSTP80-3030NSG1B

80 Liter

30" x 30"

3/16"

10/Pack

JIP-GSTP08-1217NSG1B

8 Liter

12" x 17"

3/16"

10/Pack

JIP-GSTP1003036NSG1B

100 Liter

30" x 36"

3/16"

10/Pack

JIP-GSTP09-1218NSG1B

9.5 Liter

12" x 18"

3/16"

10/Pack

JIP-SEP5007-NSCV-10

Replacement Septa

JIP-GSTP10-1219NSG1B

10 Liter

12" x 19"

3/16"

10/Pack

10/Pack

AIR SAMPLING

31


AIR MONITORING

Direct Read Passive Monitoring System ChromAir® System Chemical Detection Badges In some settings, monitoring the amount of exposure is the key to safe working conditions. ChromAir® is designed to detect exposure dose levels to specific toxic chemicals. The ChromAir® chemical exposure monitoring badge offers six exposure levels, with most indicating from one-tenth to two times the Permissible Exposure Limit (PEL) Time Weighted Average (TWA) for an eight-hour work period. To determine the average concentration, users can locate the highest cell with a color change and divide the corresponding dose level (parts per million times hour) by the sampling time in hours. For higher resolution and accuracy, the ChromAir® badges can-be-used with the ChromAir® color comparators. The color scales on the color comparator identically match the colors formed on the ChromAir® badge.

Features • Easy to read color change • Highly sensitive and selective • Exposure data read directly from badge • Measure TWA exposure • Immediate response for short-term exposure measurements • Patented design minimizes effects of humidity and velocity • Light-weight and cost effective for personnel and area monitoring

ChromAir® Badges Part Number

Chemical

Range

Interferences

Quantity

MT-380003-10

Ammonia

4 - 300 ppm/hr

RNH2

10/Pack

MT-380008-10

Carbon Monoxide

10 - 525 ppm/hr

Alkenes, H2, H2S

10/Pack

MT-380004-10

Chlorine

0.4 - >13 ppm/hr

Br2, HCl, I2

10/Pack

MT-380007-10

Formaldehyde

0.3 - 12 ppm/hr

Acrolein

10/Pack

MT-380017-10

Glutaraldehyde

0.04 - 0.95 ppm/hr

None Known

10/Pack

MT-380018-10

Mercury

0.125 - 1.6 mg/m3/hr

Strong Oxidizers

10/Pack

MT-380010-10

Ozone

0.08 - 1.6 ppm/hr

H2O2, NO2

10/Pack

3

*1ChromAir® glutaraldehyde STEL badges are for 15 minutes of monitoring only. The scale on the badge is in ppm *2ChromAir® mercury badge and color comparator scale is in mg/m3 hr *3Coefficient must be applied to scale printed on badge *4ChromAir® ozone badges are ten times more sensitive to ozone than nitrogen dioxide Accessories Part Number

Description

MT-401966-10

Strap Clips, 10/Pack

MT-401966-100

Strap Clips, 100/Pack

MT-401966-500

Strap Clips, 500/Pack

How Colorimetric Detection Chemistry Works

Inf Z 32

ne

Color originates from the complex and fascinating interaction of visible light with chromophores, or groups of atoms in molecules which are capable of absorbing certain wavelengths of visible light. Due to this absorption phenomenon, these substances are perceived as having color. The hue and depth of the perceived color are related to the specific wavelengths absorbed and the intrinsic absorption efficiency of the molecule, respectively. The distribution of electron density in a molecule is responsible for the absorption characteristics of that molecule. The alteration of electron density distribution in a molecule through reaction with another chemical species forms the basis for colorimetric chemical detection.

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

SafeAir® System Chemical Detection Badges When there is a threat of chemical hazard, immediate detection is paramount. The SafeAir® System offers immediate visual confirmation of a specific chemical hazard. SafeAir® chemical detection badges are available for many different toxic industrial chemicals. The highly sensitive and selective sensor in the SafeAir® badge is designed to show a homogeneous and stable color change, which appears as an exclamation point when a particular chemical is present. For higher resolution and wider range, the SafeAir® badges can-be-used with the SafeAir® color comparator. Slide the SafeAir® badge with the exclamation point facing up into the color comparator and turn the wheel until the colors match. Read the exposure dose in the exposure dose window. Features • Easy to use • Highly sensitive and selective • Ideal for daily employee screening or leak detection • Measure TWA exposure • Immediate, on-site results • No calibration or laboratory analysis needed SafeAir® System Badges Part Number

Chemical

Threshold Level

Interferences

Comparator Part Number

Quantity

MT-382010-50

Ammonia

4 ppm/hr

Primary Aliphatic Amines

-

50/Pack

MT-382001-50

Aromatic Isocyanates (TDI & MDI)

TDI: 5 ppb/hr MDI: 3.5 ppb/hr

Other Aromatic Isocyanates

TDI: MT-383005

50/Pack

MT-382012-50

Carbon Monoxide

7 ppm/hr

Alkenes, H2, H2S

-

50/Pack

MT-382009-50

Chlorine

0.18 ppm/hr

Br2, HCl, I2

MT-383010

50/Pack

MT-382003-50

Chlorine/Chlorine Dioxide

Cl2: 0.18 ppm/hr ClO2 : 0.2 ppm/hr

Cl2: Br2, HCl, I2 ClO2: NO2, High Concentration O3

-

50/Pack

MT-382011-50

Formaldehyde

0.2 ppm/hr

Acrolein

-

50/Pack

MT-382002-50

Hydrazine

8 ppb/hr

MMH, Aromatic Amines

MT-383001

50/Pack

MT-382020-50

Hydrazine Dual-Level

Front: 8 ppb/hr Back: 4 ppb/hr

MMH, Aromatic Amines

-

50/Pack

MT-382015-50

Hydrogen Sulfide

2 ppm/hr

None Known

-

50/Pack

MT-382005-50

Mercury

Front: 0.25 mg/m3/hr Back: 0.08 mg/m3/hr

Strong Oxidizers

-

50/Pack

MT-382004-50

Ozone

0.05 ppm/hr

H2O2, Above 1 ppm NO2

-

50/Pack

MT-382036-50

Phosgene

8.3 ppb/hr

COBr2, CNCl, ClCO2

MT-383016

50/Pack

MT-382065-100

Phosgene Dura

20 ppb/hr

COBr2, CNCl, ClCO2

MT-383022

100/Pack

MT-382060-100

Phosgene Medi

166.7 ppb/hr

COBr2, CNCl, ClCO2

MT-383020

100/Pack

MT-382014-50

Sulfur Dioxide

0.2 ppm/hr

None Known

-

50/Pack

Color Comparators Part Number

Description

Range

Quantity

MT-383005

Color Comparator For TDI SafeAir System Badges

5 - 140 ppb/hr

Each

MT-383010

Color Comparator For Chlorine SafeAir® System Badges

0.03 - 3 ppm/hr

Each

MT-383001

Color Comparator For Hydrazine SafeAir® System Badges

4.5 - 300 ppb/hr

Each

®

MT-383016

Color Comparator For Phosgene SafeAir System Badges

0.5 - 450 ppm/min

Each

MT-383022

Color Comparator For Phosgene Dura SafeAir® System Badges

1.2 - 450 ppm/min

Each

MT-383020

Color Comparator For Phosgene Medi SafeAir® System Badges

10 - 450 ppm/min

Each

®

Accessories Part Number

Description

MT-401966-10

Strap Clips, 10/Pack

MT-401966-100

Strap Clips, 100/Pack

MT-401966-500

Strap Clips, 500/Pack

MT-401967-500

Adhesive Discs, 500/Pack AIR MONITORING

33


AIR MONITORING

The easiest to use colorimetric gas detector tube pump! AP-20S Gas Detection Pump The Sensidyne AP-20S gas detection pump kit when used in conjunction with Sensidyne detector tubes is a portable gas detection system that is lightweight, rugged, and capable of on-the-spot detection of numerous gases and vapors . Features • First detector tube pump with an antibacterial blue grip • Sample flow indicator • Detector tube tip cutter and storage • Two-stage locking pump mechanism on the pump handle that allows sampling of either 50 ml or 100 ml sample volumes • Pump has a positive start and stop for each stroke • Withstands harsh environments and comes with a lifetime warrant Includes • AP-20S gas detection pump • Two rubber tube-connectors • Lubricant • Tube handbook • Manual • Transport cage

Part Number

Description

GIL-830-0001-01

AP-20S Gas Detection Pump Kit

GIL-830-1001-01

5 m Extension Hose For AP-20S Pump

GIL-830-1002-01

10 m Extension Hose For AP-20S Pump

GIL-830-1003-01

2 m Telescoping Extension Probe

Tip Cutter

Sampling Flow Indication

*Sensidyne pump and Sensidyne colorimetric gas detector tubes are not interchangeable with other manufacturers’ pumps and detector tubes

Sensidyne Colorimetric Gas Detector Tubes The Sensidyne colorimetric gas detector tubes safely allow users to perform field screening and tests for the presence of hazardous and toxic gases, and chemical vapors at a very low cost-per-sample. Gas detector tubes from Sensidyne are precision tubes offering a higher level of accuracy and repeatability for applications where results matter.

Applications • Metal fabrication • Degreasing • Welding • Sewage & waste water treatment plants • Aerospace manufacturing • Hazardous water handling • Railroad & tank cars • Parking garages • Laboratory • Pharmaceutical & medical manufacturing • Food manufacturing

34

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Features • Detector tubes for hundreds of gases • Easy to use & provides a low-cost method of routine or spot sampling for gases & vapors • Most tubes use a single pump stroke • Plastic coating on the glass makes them shatterproof • Uses smaller particles, which make the color change brighter and easier to see • Perfect when sampling for a known target gas • When the target gas or substance is unknown, the specialty HazMat kits provide an excellent answer for quick identification & measurement

Extensive List Of Gases & Ranges CALL US TODAY! 1-888-287-3732 Acetaldehyde

Chlorobenzene

Ethyl Alcohol

Isopropyl & Ethyl Acetate

Nitric Acid Vapor

Silane

Acetic Acid

Chloroform

Ethyl Benzene

Isopropyl Alcohol

Nitric Oxide & NO2

Styrene

Acetone

Chloropicrin

Ethyl Mercaptan Ethylene

MEK & Dioxane

Nitrogen Dioxide

Sulfide Ion In Water

Acetylene

Chloroprene

Ethylene Dibromide

Mercaptans

O-Dichlorobenzene

Sulfur Dioxide

Acrolein

Copper Ion In Water

Ethylene Glycol

Mercury Vapor

Oil Mist Compressed Breathing Air Tube

Sulfuric Acid

Acrylonitrile

Cyclohexane

Ethylene Oxide

Methyl Alcohol

Organic compounds

Tetrachloroethylene

Ammonia

Cyclohexanol

Formaldehyde

Methyl Bromide

Organic gases Oxygen & Carbon Dioxide

Tetraethoxysilane

Aniline

Cyclohexanone

Furfuryl Alcohol

Methyl Chloroform

Oxygen

Tetrahydrofuran

Arsine

Diborane

Gasoline

Methyl Cyclohexane

Oxygen Compressed Breathing Air Tube

Toluene

Benzene

Dichloroethane

General Hydrocarbons

Methyl Cyclohexanol

Ozone

Trichloroethylene

Bromine

1,2-Dichloroethylene

Hydrazine

Methyl Ethyl Ketone

P-Dichlorobenzene

Triethylamine

Butadiene

2,2-Dichloroethyl Ether

Hydrocarbons

Methyl Iodide

Pentyl Acetate

Vinyl Acetate

2-Butanol

Dichloromethane

Hydrogen

Methyl Isobutyl Ketone

Ozone

Vinyl Chloride

Butyl Acetate

1,3-Dichloropropane

Hydrogen Chloride

Methyl Mercaptan

Phenol & Cresol

Water Vapor

Carbon Dioxide

Diethyl & Trimethyl Amine

Hydrogen Cyanide

Methyl Methacrylate & Allyl Alcoho

Phosgene

Water Vapor Compressed Breathing Air Tube

Carbon Disulfide

Diethyl Ether

Hydrogen Fluoride

Methyl Styrene

Phosphine & Arsine

Water Vapor

Carbon Monoxide

Dimethyl & Ethyl & Methyl Amine

Hydrogen Peroxide

Monoethanol Amine

Phosphine

Xylene

Carbon Tetrachloride

Dimethyl Ether

Hydrogen Selenide

N,N-Dimethyl Formamide Propane

Carbonyl Sulfide

Epichlorohydrin

Hydrogen Sulfide

N,N-Dimethylacetamide

Propyl Acetate

Chloride Ion In Water

Ethyl & Butyl & Isobutyl Acrylate

Hydrogen Sulfide & Mercaptans

N-Butane

Propylene

Chlorine

Ethyl & Methyl Cellosolve

Isobutyl Acetate

N-Hexane

Propylene Oxide

Chlorine Dioxide

Ethyl Acetate

Isobutyl Alcohol

Nickel Carbonyl

Salinity In Water

*Sensidyne pump and Sensidyne colorimetric gas detector tubes are not interchangeable with other manufacturers’ pumps and detector tubes

Inf Z

ADVANTAGES

ne

• Most of our tubes use a single pump stroke • Pump has a positive start and stop for each stroke • Uses smaller particles, which make the color change brighter and easier to see • Plastic coating on the glass, makes them shatterproof • Pump has an anti-bacterial grip, making it safer to use in medical settings • Competitive pricing • Extensive list of gases AIR MONITORING

35


AIR MONITORING

Dräger accuro® Gas Detection Pump The Dräger accuro® pump is a manually operated bellows pump that draws a calibrated 100 ml sample through the Short-Term Dräger-Tubes® for the sampling of toxic gases and vapors. It is independent of external energy sources therefore, there are no usage restrictions in areas of explosion hazard. An internal scissor mechanism built into the Dräger accuro® pump bellows provides parallel compression of the pump and an automatic stroke counter, which is integrated in the pump head, records the number of strokes. Features • For short-term measurements with a small numbers of strokes • Hand-operated bellows pump with one-handed operation • Built-in automatic stroke counter • End-of-stroke indicator • Number of Strokes: 1 - 50 strokes and higher • Stroke volume: 100 ml (±5%)

Part Number

Description

Includes

DR-6400000

accuro® Pump

• accuro® Pump • Tube Opener • Allen Wrench

DR-8317186

Soft-Side accuro® Pump Kit

• accuro® Pump • Tube Opener • Allen Wrench

• Spare Parts Kit • NylonTransport Case

DR-4056443

Hard-Side accuro® Pump Kit

• accuro® Pump • Tube Opener • Allen Wrench

• Spare Parts Kit • (10) Rubber Caps • Pelican® Plastic Transport Case

DR-6400561

1 m Extension Hose For Dräger accuro® & Dräger X-act® 5000 Pumps

• 1 m Extension Hose • Adapter For Simultaneous Test Sets

*3 m & 10 m extension hose also available *Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes

X-act® 5000 Automatic Tube Pump The Dräger X-act® 5000 all-in-one, automatic tube pump is used in conjunction with Short-Term Dräger-Tubes®, simultest sets, and sorbent tubes for the sampling of toxic gases and vapors in the workplace. The bar code reader transfers all relevant measurement parameters using the bar code on the box of Dräger-Tubes. Features • For short-term measurements with higher numbers of strokes and sample taking with sampling tubes and systems • Menu-driven automatic pump • Built-in barcode reader with Class 3R • Number of strokes: adjustable 1 - 199 strokes • Stroke volume: 100 ml (±5%) • (6) AA alkaline batteries or rechargeable NiMH battery pack • Protection class: Ex-approved, IP 64

Part Number

Description

Includes

DR-4523500

Dräger X-act 5000 Pump

• X-act® 5000 Pump • Shoulder Strap

DR-4523617

Dräger X-act® 5000 Pump Kit

• X-act® 5000 Pump • Shoulder Strap

DR-6400561

1 m Extension Hose For Dräger accuro® & Dräger X-act® 5000 Pumps

• 1 m Extension Hose • Adapter For Simultaneous Test Sets

®

*3 m, 10 m, 15 m & 30 m extension hose also available *Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes

36

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

• Rechargeable NiMH Battery • 100-240 VAC Charger


AIR MONITORING

Short-Term Dräger-Tubes® Short-Term Dräger-Tubes® are an easy to use and cost effective way to measure toxic gases and vapors in the workplace. More than 200 different Short-Term Dräger-Tubes® are available to accurately make spot measurements for over 500 gases and vapors. The Short-Term Dräger-Tubes® are used in conjunction with either a manual or an automatic sampling pump using individual Short-Term Dräger-Tubes® or special 5 tube sets for simultaneous measurement. Applications

Features

• Determining and measuring concentration peaks • Measuring personal exposure in the inhalation area • Detecting leaks in pipelines, gas installations, etc. • Air analysis in sewers, shafts and confined spaces • Evaluation of concentration fluctuations in the workplace • Measurement of contaminants in the worker’s breathing zone • The investigation of confined spaces (ex: grain silos, chemical tanks, sewers) prior to entry • Check for gas leaks in process pipelines

• More than 200 Short-Term Dräger-Tubes® are available to measure spot concentrations of specific gases • Designed for on-the-spot measurements at a particular location over a relatively short time period • Perfect when sampling for a known target gas • Measurements in the range of the occupational exposure limits • Measurements in the area of emission concentrations • Measurements may last from 10 seconds to 15 minutes or so depending on the particular Short-Term Dräger-Tubes® and sampling pump

Environm ental

Remediation Equipment Inc.

Extensive List Of Gases & Ranges CALL US TODAY! 1-888-287-3732 Acetaldehyde

Chloroformates

Formaldehyde

Methyl Bromide

Phosphoric Acid Esters

Acetic Acid

Chloropicrin

Formaldehyde

Methylene Chloride

Polytest

Acetone

Chloroprene

Formaldehyde Activation Tube

Monostyrene

i-Propanol

Acid Test Qualitative

Chromic Acid

Formic Acid

Natural Gas Test

Pyridine

Acrylonitrile

Cyanide

Halogenated Hydrocarbons

Nickel Tetracarbonyl

Smoke Tubes

Air Current (Smoke Tubes)

Cyanogen Chloride

Hexane

Nitric Acid

Sulfur Dioxide

Amine Test Qualitative

Cyclohexan

Hydrazine

Nitrogen Dioxide

Sulfuric Acid

Ammonia

Diesel Fuel

Halogenated Hydrocarbons

Nitrous Gases

Sulfuryl Fluoride

Aniline

Diethyl Ether

Hydrocarbons

Oil

Tetrahydrothiophene

Arsine

Dimethyl Formamide

Hydrochloric Acid

Oil Mist

Thioether

Benzene

Dimethyl Sulfate

Hydrochloric Acid/Nitric Acid

Olefins (Propylene, Butylene)

Toluene

n-Butanol

Dimethyl Sulfide

Hydrogen

Organic Arsenic Compounds & Arsine

Toluene Diisocyanate

Carbon Dioxide

Epichlorohydrin

Hydrogen Fluoride

Organic Basic Nitrogen Compounds

Trichloroethane

Carbon Disulfide

Ethanol

Hydrogen Peroxide

Oxygen

Trichloroethylene

Carbon Monoxide

Ethyl Acetate

Hydrogen Sulfide + Sulfur Dioxide

Ozone

Triethylamine

Carbon Pretube

Ethyl Benzene

Hydrogen Sulfide

Pentane

Halogenated Hydrocarbons

Carbon Tetrachloride

Ethyl Glycol Acetate

Iodine

Perchloroethylene

Vinyl Chloride

Chlorine

Ethylene

Mercaptan

Petroleum Hydrocarbons

Water Vapor

Chlorine Dioxide

Ethylene Glycol

Mercury

Phenol

Xylene

Chlorobenzene

Ethylene Oxide

Methanol

Phosgene

Chloroform

Fluorine

Methyl Acrylate

Phosphine

*Dräger pumps and Short-Term Dräger-Tubes® are not interchangeable with other manufacturers’ pumps and detector tubes.

AIR MONITORING

37


AIR MONITORING

Still stuck?

Need Help Choosing A Gas Detector?

Contact us and we will help you pick the right gas detector for your project

1-888-287-3732

Answer the following questions to help narrow it down. 1. Do you require a portable or fixed gas detector? 2. Do you require a single gas or multi-gas detector? 3. What gas or gases do you need to measure?

4. Do you require an instrument without an internal pump (passive monitoring) or with an internal pump (active monitoring)? 5. Do you require an instrument with or without datalogging?

5 Versions Available CO, H2S, O2, CO/O2 & H2 Compensated CO

GasWatch 3 Single Gas Personal Monitor

The GasWatch 3 is the world’s smallest and lightest single gas and dual gas monitor designed to detect CO, H2S, O2, CO/O2 & H2 Compensated CO. Its compact form provides great comfort and flexibility in how you choose to wear it. It can be worn on your wrist as a watch, or clipped into your breathing zone on your lapel, hard hat or other safety equipment with the 360º rotation alligator clip.

38

Applications

Features

Kit Includes

• Refineries • Petrochemical facilities • Sewage treatment plants • Fire departments • Chemical plants • Tunnels • Mines • Hazardous waste sites

• Light and compact "watch type" design • Easily worn clipped in your "breathing zone" • Available with watch band or alligator clip • Automatic backlight during alarm • Sturdy IP-66/68 rated design • Water, dust and radio frequency (RF) resistant • Non-compliance indicator

• GasWatch 3 monitor • Watch band or alligator clip • Spring pins (used to mount accessories on to the rear face) • CR2450 coin-type lithium-ion battery

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


CO

Model Name

GW-3 (HS) Hydrogen Sulfide

Gas Detected

CO (-H2)

CO/O2

GW-3 (CO)

GW-3 (C-)

Carbon Monoxide

H2 Compensated CO

GW-3 (CX) Carbon Monoxide

Electrochemical

Detection Principal

Oxygen

Oxygen

Dual Electrochemical

Galvanic Cell 0 ~ 25.0% Vol. (0.1% Vol.)

Gas Sampling

Diffusion

Power Source

CR2450 coin-type lithium ion battery

Operating Temp. & Humidity

GX-3 (O2)

0 ~ 300 ppm (1 ppm)

0 ~ 30 ppm (0.1 ppm) 30 ~ 100 ppm (1 ppm)

Detection Range (Increments)

O2

AIR MONITORING

H 2S

-20°C to +50°C (no sudden changes) (Approx. 15-minute temporary use environment: -20°C to +60°C) [no sudden changes]

-20°C to +50°C (no sudden changes)

10 to 90% RH (no condensation) (Approx. 15-minute temporary use environment: 0 to 95% RH) [no condensation]

10 to 90% RH (no condensation)

ATEX, IECEx, CSA

Safety Rating

Part Number

Description

Model

Detection Range

Calibration Equipment

RK-73-0022-01

GasWatch 3 For H2S With Wrist Band

GX-3 (HS)

0 ~ 30 ppm 30 ~ 100 ppm

• NLB-F105325PN • NLB-517 • RK-81-1194

• RK-06-1248RK-03 • NLB-500D

RK-73-0023-01

GasWatch 3 For CO With Wrist Band

GX-3 (CO)

0 ~ 300 ppm

• NLB-H101650PN • NLB-417 • RK-81-1194

• RK-06-1248RK-03 • NLB-500D

RK-73-0025-01

GasWatch 3 For CO With H2 Compensated Sensor & Wrist Band

GX-3 (C-)

0 ~ 300 ppm

• NLB-H101650PN • NLBH1049200PA • NLB-417

• RK-81-1194 • RK-06-1248RK-03 • NLB-500D

RK-73-0026-01

GasWatch 3 For CO/O2 Combination With Wrist Band

GX-3 (CX) (Dual Sensor)

CO: 0 ~ 300 ppm O2: 0 ~ 25.0% Vol.

• NLB-H101650PN • NLB-H1066 • NLB-417

• RK-81-1194 • RK-06-1248RK-03 • NLB-500D

RK-72-0012-01

GasWatch 3 For O2 With Wrist Band

GX-3 (O2)

0 ~ 25.0% Vol.

• NLB-H1066 • NLB-417 • RK-81-1194

• RK-06-1248RK-03 • NLB-500D

*GasWatch 3 with alligator clip models also available

AUTHORIZED RKI SERVICE CENTER Accessories & Calibration Equipment Part Number

Description

NLB-F105325PN

Calibration Gas 25 PPM H2S In N2, 34 Liter Steel Cylinder With CGA 600

NLB-H101650PN

Calibration Gas 50 PPM CO In N2, 34 Liter Steel Cylinder With CGA 600

NLB-H1049200PA

Calibration Gas 200 PPM H2 in Air, 34 Liter Steel Cylinder With CGA 600

NLB-H1066

Calibration Gas 100% N2, 34 Liter Steel Cylinder With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-517

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

RK-81-1194

Calibration Adapter For GasWatch 3

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-500D

Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders AIR MONITORING

39


AIR MONITORING

4 Versions Available LEL, O2, H2S & CO 03 Series Single Gas Clip-On Personal Monitor The 03 Series single gas monitors are designed for LEL, O2, H2S or CO detection. Individuals need personal protection in hazardous areas at all times without adding extra bulky equipment and the 03 Series can provide that kind of protection at an affordable price.

Applications

GEM

Kit Includes

• Hazardous material • Mining • Tunnels • Refineries / petrochemical • Water / waste water treatment • Pharmaceutical manufacturing • Utilities • Chemical plants • Fire services

5000

• GP-03, OX-03, HS-03 or CO-03 monitor • Alligator clip • Screwdriver • (2) AAA alkaline batteries • Rubber boot • Quick reference card • Small padded case

Features • Data log 5 to 30 hours with adjustable intervals • Peak hold, STEL and TWA • Audible, vibration and visual alarms • Automatic backlight • Low battery alarm • Impact, dust and water resistant (IP-67) • Replaceable rubber boot

Model

Gas Detected

CO-03

Carbon Monoxide (CO)

Hydrogen Sulfide (H2S)

0 - 500 ppm (1 ppm)

0 - 100 ppm (0.5 ppm)

± 5% of reading or ± 5 ppm (CO)

± 5% of reading or ± 2 ppm (H2S)

Data Logging

GP-03

Oxygen (O2)

Combustible Gas

Galvanic Cell

Catalytic Combustion

0 - 40% Vol. (0.1% Vol.)

0 - 100% LEL (1% LEL)

Diffusion

Gas Sampling Accuracy (Whichever Is Greater)

OX-03

Electrochemical

Detection Principal Detection Range (Increments)

HS-03

± 0.5% Vol. (O2)

± 5% of reading or ± 2% (LEL)

10 second intervals = 5 hours, 5 minute intervals = 150 hours, 10 minute intervals = 300 hours Instrument records alarms, alarm trends, gas readings, calibration & bump test history, instrument information and settings

Alkaline dry cell (2-AAA size)

Power Source

20°C ~ 50°C (-4°F ~ 122°F); Humidity below 90% RH (non-condensing)

Operating Temp. & Humidity Safety Rating

40

Alkaline dry cell (2-AAA size) Ni-MH battery

ATEX/IECEx approved, CSA classified, "C/US", as intrinsically safe, Class I, Division 1, Groups A, B, C, D

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING SDM-03 Single Point Calibration Station

Part Number

Description

Model

Detection Range

Calibration Equipment

RK-73-0060-50

03 Series For CO

CO-03

0 - 500 ppm

• NLB-H101650PA • NLB-417 • RK-81-1146

• RK-06-1248RK-03 • NLB-500D

RK-73-0062-50

03 Series For H2S

HS-03

0 - 100 ppm

• NLB-F105325PN • NLB-517 • RK-81-1146

• RK-06-1248RK-03 • NLB-500D

RK-72-0010-50

03 Series For O2

OX-03

0 - 40% Vol.

• NLB-H1066 • NLB-417 • RK-81-1146

• RK-06-1248RK-03 • NLB-500D

RK-72-0037-50

03 Series For LEL

GP-03

0 - 100% LEL

• NLB-H197150LA • NLB-417

• RK-81-1146 • RK-06-1248RK-03 • NLB-500D

Accessories & Calibration Equipment Part Number

Description

RK-81-SDM03-01

SDM-03 Single Point Calibration Station For 03 Series With AC Adaptor, Flash Drive, USB Cable & Tubing

NLB-H101650PA

Calibration Gas 50 PPM CO In Air, 34 Liter Steel Cylinder With CGA 600

NLB-F105325PN

Calibration Gas 25 PPM H2S In N2, 34 Liter Steel Cylinder With CGA 600

NLB-H1066

Calibration Gas 100% N2, 34 Liter Steel Cylinder With CGA 600

NLB-H120815LA

Calibration Gas 15% LEL Hexane In Air, 34 Liter Steel Cylinder With CGA 600

NLB-H197150LA

Calibration Gas 2.5% CH4 (50% LEL) In Air, 34 Liter Steel Cylinder With CGA 600

NLB-H104950LA

Calibration Gas 2.00% H2 (50% LEL) In Air, 34 Liter Steel Cylinder With CGA 600

NLB-H196950LA

Calibration Gas 50% LEL Isobutane In Air, 34 Liter Steel Cylinder With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-517

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

RK-81-1146

Calibration Adapter For 03 Series

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-500D

Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders

AIR MONITORING

41


AIR MONITORING

Dräger Pac® Series - Fast & Robust Single Gas Detection Devices The Dräger Pac® series is available with a wide variety of sensors. They provide fast and reliable gas detection to ensure life safety in your facility. Features • Easy to use and are manufactured using the latest technology • Devices are very robust with a 360° alarm signal, clear color coding as well as a large, language-free display • The green illuminating D-Light indicates whether the functionality of the device has been tested • Each sensor variant of the Dräger Pac® series features a clear, well visible color coding, thereby minimizing the chance of mistakes

Dräger Pac® 6000 The Dräger Pac® 6000 disposable personal gas detector measures CO, H2S, SO2 or O2 reliably and precisely, even in the toughest conditions. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years of 24/7 operation (1 year for O2) with virtually no maintenance required. Part Number

Description

Measuring Range

Resolution

Calibration Equipment

DR-8327611

Dräger Pac 6000 For Carbon Monoxide (CO)

0 - 2000 ppm

1 ppm

• NLB-H1016100PN • NLB-417 • DR-4594501

DR-8326368

Dräger Pac® 6000 For Hydrogen Sulfide (H2S)

0 - 100 ppm

0.1 ppm

• NLB-F105325PN • NLB-517 • DR-4594501

DR-8327612

Dräger Pac® 6000 For Oxygen (O2)

0 - 25% Vol.

0.1% Vol.

• NLB-H107217VN • NLB-417 • DR-4594501

DR-8328273

Dräger Pac® 6000 For Sulphur Dioxide (SO2)

0 - 100 ppm

0.1 ppm

• NLB-F107910PN • NLB-517 • DR-4594501

®

*Fully configurable Dräger Pac® 6000 single gas monitor also available

Dräger Pac® 6500 The robust Dräger Pac® 6500 is your reliable companion under tough conditions. The personal single-gas detection device measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a replaceable battery also ensure safety. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery for 2 years of 24/7 operation (1 year for O2). Part Number

Description

Measuring Range

Resolution

Calibration Equipment

DR-8327615

Dräger Pac 6500 For Carbon Monoxide (CO)

0 - 2000 ppm

1 ppm

• NLB-H1016100PN • NLB-417 • DR-4594501

DR-8327613

Dräger Pac® 6500 For Hydrogen Sulfide (H2S)

0 - 100 ppm

0.1 ppm

• NLB-F105325PN • NLB-517 • DR-4594501

DR-8327616

Dräger Pac® 6500 For Oxygen (O2)

0 - 25% Vol.

0.1% Vol.

• NLB-H107217VN • NLB-417 • DR-4594501

DR-8328274

Dräger Pac® 6500 For Sulphur Dioxide (SO2)

0 - 100 ppm

0.1 ppm

• NLB-F107910PN • NLB-517 • DR-4594501

®

*Fully configurable Dräger Pac® 6500 single gas monitor also available

42

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


With the robust Dräger Pac® 8000, you’ll be well equipped for tough conditions: this non-disposable, personal single-gas detection device is a reliable and precise instrument, which detects hazardous concentrations of twenty nine different gases, including special gases like NO2, O3 or COCl2. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery for 2 years of 24/7 operation.

Part Number

Description

Measuring Range

Resolution

Calibration Equipment

DR-8326350

Dräger Pac® 8000 For Nitric Oxide (NO)

0 - 200 ppm

1 ppm

• NLB-F166025PN • NLB-517 • DR-4594501

DR-8328275

Dräger Pac® 8000 For Nitrogen Dioxide (NO2 LC)

0 - 50 ppm

0.02 ppm

• NLB-F106710PN • NLB-517 • DR-4594501

DR-8326351

Dräger Pac® 8000 For Carbon Dioxide (CO2)

0 - 5% Vol.

0.1% Vol.

• NLB-H10132.5VN • NLB-417 • DR-4594501

DR-8326352

Dräger Pac® 8000 For Chlorine (CL2)

0 - 20 ppm

0.1 ppm

• NLB-ZB10175PN • NLB-517SS • DR-4594118

DR-8328276

Dräger Pac® 8000 For Hydrogen Cyanide (HCN)

0 - 50 ppm

0.1 ppm

• NLB-F105110PN • NLB-517 • DR-4594501

DR-8328277

Dräger Pac® 8000 For Ammonia (NH3)

0 - 300 ppm

1 ppm

• NLB-F100550PN • NLB-517SS • DR-4594118

DR-8326355

Description Dräger Pac® 8000 For Phosphine (PH3)

0 - 20 ppm

0.1 ppm

• NLB-F2199.5PN • NLB-517 • DR-4594501

DR-8326356

Dräger Pac® 8000 For Organic Vapours (OV)

0 - 200 ppm

0.5 ppm

• NLB-F104010PN • NLB-517 • DR-4594501

DR-8326357

Dräger Pac® 8000 For Organic Vapours (OV-A)

0 - 200 ppm

1 ppm

• NLB-F104010PN • NLB-517 • DR-4594501

DR-8326359

Dräger Pac® 8000 For Ozone (O3)

0 - 10 ppm

0.01 ppm

Contact us for more information

DR-8326360

Dräger Pac® 8000 For Phosgene (COCl2)

0 - 10 ppm

0.01 ppm

Contact us for more information

AIR MONITORING

Dräger Pac® 8000

*Fully configurable Dräger Pac® 8000 single gas monitor also available

Dräger Pac® 8500 The Dräger Pac® 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or a Dräger dual sensor. The dual sensors provide the option of measuring two gases at once: either H2S with CO or O2 with CO. It features a full data logger, exposure alarms (STEL/TWA) and a powerful battery. Part Number

Description

Measuring Range

Resolution

Calibration Equipment

DR-8326365

Dräger Pac® 8500 For Hydrogen Sulfide / Carbon Monoxide (H2S LC/CO LC)*

0 - 2000 ppm CO / 0 - 100 ppm H2S

1 ppm CO / 0.1 ppm H2S

• NLB-F105325PM73 • NLB-517 • DR-4594501

DR-8326366

Dräger Pac® 8500 For Oxygen / Carbon Monoxide (O2/CO LC)*

0 - 25% Vol. O2 / 0 - 2000 ppm CO

0.1% Vol. O2 / 1 ppm CO

• NLB-F105325PM73 • NLB-517 • DR-4594501

DR-8328262

Dräger Pac® 8500 For Carbon Monoxide Hydrogen Compensated (CO H2-CP)

0 - 2000 ppm

2 ppm

• NLB-H1049500PA • NLB-417 • DR-4594501

*CO alarms for these devices are set to: A1 35 ppm and A2 50 ppm *Fully configurable Dräger Pac® 8500 single gas monitor also available

AIR MONITORING

43


AIR MONITORING

Accessories & Calibration Equipment Part Number

Description

DR-8325646

GasVision 7 Software License

DR-5600704

USB Communication Cradle For Dräger Pac® Monitors

DR-8318587

Communication Cradle & USB Cable

DR-8317410

Dräger Pac® Bump Test/Calibration Station (Gas Cylinder Sold Separately)

DR-8318588

Bump Test/Calibration Adaptor (Hose, Regulator & Gas Cylinder Sold Separately)

DR- 8321881

Dräger X-dock® 5300 Pac Station, Set Consisting Of One Master (Up To 3 Gases) With Power Supply & One Instrument Module For the Dräger Pac® Series 6000/6500/8000/8500 (Regulator Sold Separately)

NLB-H1016100PN

Calibration Gas 100 PPM CO In N2, 34 Liter Steel Cylinder With CGA 600

NLB-F105325PN

Calibration Gas 25 PPM H2S In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-H107217VN

Calibration Gas 17% O2 In N2, 34 Liter Steel Cylinder With CGA 600

NLB-F107910PN

Calibration Gas 10 PPM SO2 In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-F166025PN

Calibration Gas 25 ppm NO In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-F106710PN

Calibration Gas 10 ppm NO2 In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-H10132.5VN

Calibration Gas 2.5% Vol. CO2 In N2, 34 Liter Steel Cylinder With CGA 600

NLB-ZB10175PN

Calibration Gas 5 ppm CL2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-F105110PN

Calibration Gas 10 ppm HCN In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-F100550PN

Calibration Gas 50 ppm NH3 In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-F2199.5PN

Calibration Gas 0.5 ppm PH3 In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-F104010PN

Calibration Gas 10 ppm Ethylene Oxide (For OV Sensors) in N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-F105325PM73

Calibration Gas 25 PPM H2S / 100 PPM CO / 2.5% CH4 (50% LEL) / 17% O2 In N2, 34 Liter Aluminum Cylinder With CGA C-10

NLB-H1049500PA

Calibration Gas 500 ppm H2 In Air, 34 Liter Steel Cylinder With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-517

0.5 LMP Regulator With Gauge & Knob For Cylinders With CGA C-10

DR-4594501

10 ft Tygon® Sampling Hose

DR-4594118

5 ft PTFE Lined Reactive Gas Sampling Hose

NLB-500D

Case For 17 / 29 / 34 Liter Steel Cylinders, Holds 2 Cylinders

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

SERVICE & CALIBRATE your instruments with our Authorized Service Center!

ASK FOR YOUR

FREE RENTAL CATALOG

TODAY Call our toll free:

1-888-287-3732

Inf Z 44

ne

Trust our Knowledgeable Customer Service Representatives to help you determine what equipment is best for your applications!

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Fully configurable Dräger X-am® 5100 single gas monitor Dräger X-am® 5100 The Dräger X-am® 5100 is a small lightweight single gas monitor which is specifically designed for the requirements of personal monitoring. It can be equipped with an electrochemical sensor for hydrazine, hydrogen fluoride / hydrogen chloride or hydrogen peroxide. For manufacturing petrochemical products, aseptic packing, or handling of rocket fuel: the Dräger X-am® 5100 portable single-gas detector ensures safe handling of HF, HCl, H2O2 or hydrazine - thanks to proven Dräger sensor technology and a device design which is perfectly customized to reactive gases.

It’s as simple as 1, 2, 3... Step 1 — Configurable X-am® 5100 Part Number

Description

DR-8322750

X-am® 5100 Without Sensors Or Battery

Step 2 — Choose 0-1 XS DrägerSensor® Part Number

Description

Measuring Range

Resolution

DR-6809190 DR-6809140

XS DrägerSensor For Hydrazine (N2H4) XS

0 - 3.00 ppm

0.01 ppm

XS DrägerSensor® For Hydrogen Fluoride / Hydrogen Chloride (HF/HCl) XS

0 - 30.0 ppm

0.1 ppm

DR-6809170

XS DrägerSensor For Hydrogen Peroxide (H2O2) XS

0 - 20.0 ppm

0.1 ppm

®

®

Step 3 — Choose Battery Type Part Number

Description

DR-8322237

Alkaline Battery Holder (Requires 2 "AA" Alkalines)

DR-8318704

NiMH Battery Pack

DR-8318785

NiMH Battery & Charger Kit

DR-8322244

High Capacity NiMh Battery Pack

DR-8322785

High Capacity NiMh Battery & Charger Kit

Accessories Part Number

Description

DR-8317409

USB-IR Communication Cable

DR-8325646

GasVision 7 Software License

DR-6806291

Calibration Adapter With 3 ft Of Tubing

DR-4543755

Deluxe Instrument Transport Case For X-am® 1/2/5000

DR-4543936

High Visibility Yellow Heavy-Duty Transport Case

DR-4594631

Nylon Transport Case

AIR MONITORING

45


AIR MONITORING

GX-2009 Personal Multi-Gas Monitor The GX-2009 simultaneously monitors and displays LEL, O2, CO, and H2S. The GX-2009 is also functional with the SDM-2009 single calibration station and the Data Cal 2000 instrument maintenance system. It is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies. Applications

Features

• Personal monitoring • Confined spaces • Refineries / petrochemical • Oil & gas • Utilities • Hazardous material • Water/waste water treatment • Fire services • Construction

• Simultaneous detection of 4 gases, LEL, O2, H2S & CO • STEL and TWA readouts • Dual audible alarm ports (95 db @ 30 cm) • 3 visual alarm LED’s • Vibration alarm • Calibration and bump test lock out or reminder controls • Large capacity data logging standard • 8 alarm trends • Log time range of 10 to 300 hours • 100 calibration records stored • Automatic backlighting at alarm • Impact resistant rubber over-mold body, RFI shielded body • IP-67 water-resistant/dustproof design

Kit Includes • GX-2009 monitor • Wrist strap • Alligator clip • 115/220 VAC adapter for charger • (2) NiMH battery set with hardware • BC-2009 charging station base only

Model

GX-2009 Combustible Gases (Methane (CH4) as standard)

Gas Detected

Oxygen (O2)

Hydrogen Sulfide (H2S)

Carbon Monoxide (CO)

Detection Principal

Catalytic Combustion

Galvanic Cell

Detection Range (Increments)

0 - 100% LEL (1% LEL)

0 - 40% Vol. (0.1% Vol. )

0 - 100 ppm (0.5 ppm)

Electrochemical Cell 0 - 500 ppm (1 ppm)

Accuracy (Whichever Is Greater)

± 5% of reading or ±2% LEL

± 0.5% O2

± 5% of reading or ± 2 ppm H2S

± 5% of reading or ± 5 ppm CO

Diffusion sampling standard / hand aspirator or motorized pump optional

Sampling Method

(2) direct charging NiMH batteries

Power Source

-20°C ~ +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing (splash resistant)

Operating Temp. & Humidity

IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; (optional MSHA version also available)c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D

Safety Rating

Part Number

Description

Calibration Equipment

RK-72-0314RKC

GX-2009 4-Gas Personal Monitor For LEL/O2/H2S/CO With Alligator Clip & 115/220 VAC Charger

• NLB-Z105325PM51 • NLB-517 • RK-81-1107RK • RK-06-1248RK-03 • RK-03NLB-505

*Other configurations are also available *GX-2009 personal multi-gas monitor mining version also available

Accessories & Calibration Equipment

46

Part Number

Description

RK-81-SDM2009-01

SDM 2009 Single Point Calibration Station For GX-2009 With AC Adaptor, Flash Drive, USB Cable & Tubing

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-517

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

RK-81-1107RK

Rubber Calibration Sample Cap For GX-2009

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

PC-915-1001

Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

World’s Smallest & Lightest 4 Gas Monitor GX-3R Personal 4-Gas Confined Space Monitor The GX-3R simultaneously monitors and displays LEL combustibles, O2, CO (H2 compensated CO also available) and H2S. The LEL sensor has a unique design with two active filaments in one sensor to increase its resistance to silicone poisoning. If one filament gets poisoned the second filament takes over.

Features

Applications

• Simultaneous detection of 4 gases: LEL, O2, H2S & CO (H2 Compensated CO sensor available) • Simple 2-button operation • 3 user adjustable alarm levels • Audible, visual & vibration alarms • Non-compliance indicator • Large LCD Auto-backlit display • Field replaceable sensors & filters • Impact resistant body with removable rubber boot • Water and dust resistant design, IP66/68

• Personal monitoring • Confined spaces • Refineries / petrochemical • Oil & gas • Utilities • Hazardous material • Water/waste water treatment • Fire services • Construction

Model

Kit Includes • GX-3R monitor • Wrist strap • Alligator clip • Rubber boot

• Calibration adapter • Li-Ion battery pack • 100-240 VAC charger

GX-3R

Gas Detected

Carbon Monoxide (CO) H2 Compensated

Sensor Slot

1

Detection Principal

Electrochemical Cell

Carbon Monoxide (CO)

Hydrogen Sulfide Hydrogen Sulfide (H2S) (H2S) Only

Dual Sensor

Detection Range 0 ~ 2,000 ppm (1 ppm) (Increments) ± 5% of reading or ± 2 ppm CO

Accuracy (Whichever Is Greater)

Combustible Gases (Methane (CH4) as standard

Oxygen (O2)

2

3

Dual Electrochemical Cell

Electrochemical Cell

Catalytic Combustion

Electrochemical Cell

• 0 ~ 2,000 ppm CO (1 ppm) • 0 ~ 200.0 ppm H2S (0.1 ppm)

0 ~ 200.0 ppm H2S (0.1 ppm)

0 ~ 100% LEL (1% LEL)

0 ~ 40.0% Vol. (0.1% Vol.)

• ± 5% of reading or ± 5 ppm CO • ± 5% of reading or ± 2 ppm H2S

± 5% of reading or ± 2 ppm H2S

± 5% of reading or ± 2% LEL

± 5% CO2

Li-Ion battery pack

Power Source

Diffusion sampling standard / hand aspirator or motorized pump optional

Sampling Method

-20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)

Operating Temp. & Humidity

ATEX, CSA (Pending)

Safety Rating

Part Number

Description

Calibration Equipment

RK-72-RA-C

GX-3R 4-Gas Personal Monitor For LEL/O2/Combo H2S & CO With Li-Ion Battery Pack & 100-240 VAC Charger

• NLB-Z105325PM51 • NLB-513 • RK-06-1248RK-03 • NLB-505

*Other configurations are also available

Accessories & Calibration Equipment Part Number

Description

RK-81-SDM3R101

SDM-3R Calibration Station With 1 Solenoid, AC Adapter, Flash Drive, USB Cable & Tubing

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-513

0.25 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

PC-915-1001

Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)

*Optional RP-3R clip-on sample drawing pump also available.

AIR MONITORING

47


AIR MONITORING

World’s Smallest & Lightest 5 Gas Monitor GX-3R Pro Personal 4-Gas + Toxic Gas Monitor With Bluetooth The GX-3R Pro simultaneously monitors and displays 5 different gases. In addition to monitoring standard confined space gases LEL, O2, CO, & H2S, the GX-3R Pro has a 5th channel where you can add infrared or toxic sensors. Two of the four sensor slots have interchangeable sensors providing flexible configurations, which can easily be changed in the field. The GX-3R Pro utilizes Bluetooth communication to display direct gas readings from the instrument to a phone app, which is available free on either iOS or Android phones. Automatic notifications can be programmed to send text or email messages, if there is an alarm event from the GX-3R Pro.

Model Gas Detected Sensor Slot

GX-3R Pro Hydrogen Sulfide / Carbon Monoxide (H2S / CO)

Hydrogen Sulfide (H2S) Only

Carbon Monoxide (CO) H2 Compensated

1: Carbon Monoxide (CO) & Hydrogen Sulfide (H2S) *Interchangeable

2: Combustible Gases (Methane (CH4) as standard)

Detection Principal

Dual Electrochemical Cell

Detection Range (Increments)

0 ~ 2000 ppm (1 ppm)

0 ~ 200.0 ppm (0.1 ppm

0 ~ 200.0 ppm (0.1 ppm)

0 ~ 2,000 ppm

0 ~ LEL (1% LEL)

Accuracy (Whichever Is Greater)

± 5% of reading or ± 5 ppm CO

± 5% of reading or ± 2 ppm H2S

± 5% of reading or ± 2 ppm H2S

± 5% of reading or ± 2 ppm CO

± 5% of reading or ± 2 % LEL

Sampling Method

Electrochemical Cell

Combustible Gases (Methane) / Hydrocarbons (CH4 / HC)

Diffusion sampling standard (hand aspirator or clip-on motorized pump optional) Li-ion or Alkaline

Power Source (Configurable) Operating Temp. & Humidity

Catalytic Combustion

-20°C ~ +50°C [ -4°F ~ +122°F ] 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ] 0 to 95% RH, non-condensing (temporary environment)

Bluetooth Communication Safety Rating

BLE: with iOS and Android phone app: RK Link ATEX, CSA

Understanding the features of the GX-3R Pro ™

48

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


Features

• Personal monitoring • Confined spaces • Refineries / petrochemical • Utilities • Oil & gas • Water/waste water treatment • Fire Services • Law Enforcement • Construction

• Simultaneous detection of 5 gases • LEL, O2, H2S, CO, and other optional sensors • H2 Compensated CO sensor available • Simple 2-button operation • Bluetooth communication with iOS & Android App • 3 user adjustable alarm levels • Panic alarm (tap instrument twice) • Man down alarm • Non-compliance indicator • Large full dot, auto-backlit display with auto-rotation • Stealth mode for law enforcement • Field replaceable sensors & filters • Impact resistant body with removable rubber boot • Water and dust resistant design, IP66/68

AUTHORIZED RKI SERVICE CENTER

Kit Includes • GX-3R monitor • Wrist strap • Alligator clip • Rubber boot • Calibration adapter • Li-Ion battery pack • 100-240 VAC charger

AIR MONITORING

Applications

GX-3R Pro Oxygen (O2)

Hydrogen Cyanide (HCN)

Nitrogen Dioxide (NO2)

Sulfur Dioxide (SO2)

3: Oxygen (O2)

Carbon Dioxide ppm (CO2)

4: Toxics & CO2 Electrochemical Cell

0 ~ 40.0% Vol. (0.10%)

Carbon Dioxide % (CO2)

0 ~ 30.0 ppm (0.1 ppm)

± 0.5% O2

0 ~ 20.00 ppm (0.05 ppm)

Infrared 0 ~ 100.0 ppm (0.05 ppm)

0 ~ 10.0% Vol. (0.01%)

± 10% of reading or ± 5 % of full scale

0 ~ 10,000 ppm (20 ppm) ± 5% of reading or ± 2 ppm

Diffusion sampling standard (hand aspirator or clip-on motorized pump optional) Li-ion or Alkaline -20°C ~ +50°C [ -4°F ~ +122°F ] 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ] 0 to 95% RH, non-condensing (temporary environment) BLE: with iOS and Android phone app: RK Link ATEX, CSAw

Part Number

Description

Calibration Equipment

RK-72-PAA-C

GX-3R Pro 5-Gas Personal Monitor For LEL/O2/Combo H2S & CO/ppm CO2 With Li-Ion Battery Pack & 100-240 VAC Charger

• NLB-Z105325PM51 • NLB-Z10135000PN • NLB-513 • RK-06-1248RK-03 • NLB-505

*Other configurations are also available

Accessories & Calibration Equipment Part Number

Description

RK-81-SDM3R201

SDM-3R Calibration Station With 2 Solenoids (For 2 Cylinders), AC Adapter, Flash Drive, USB Cable & Tubing

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-Z10135000PN

Calibration Gas 5000 PPM CO2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-513

0.25 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

PC-915-1001

Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)

*Optional RP-3R clip-on sample drawing pump also available

AIR MONITORING

49


AIR MONITORING

Remote Sample Drawing Pump For GX-3R & GX-3R Pro RP-3R Clip-On Sample Drawing Pump The RP-3R are compact, battery operated, motorized sample drawing pumps which attach to either the GX-3R or the GX-3R Pro to change them from diffusion operation to sample drawing operation. The model RP-3R pumps and the GX-3R or GX-3R Pro gas monitor make a complete solution for confined space entry. Features • Attaches to the GX-3R in seconds (RP-3R Pro for the GX-3R Pro) • Compact and lightweight • 10 hours of operation in normal mode (higher flow mode) • 16 hours of operation in lower-flow mode (ECO mode) • Audible and visual alarms for low flow and low battery conditions • Pilot light to confirm operation • Quick disconnect fitting for hose connection • Hoses available up to 100’ length • Rugged and proven RKI reliability Kit Incudes • 4" tapered red rubber nozzle • "AA" Alkaline battery • Hydrophobic filters

Model

RP-3R

Flow Rate

Higher flow mode: 0.5 l/m Lower flow mode (ECO mode): 0.35 l/m

Alarm Display

Low flow alarm: Flow blinks YELLOW Low battery alarm: Power LED blinks GREEN

Power Supply

1 AA alkaline battery

Continuous Operation

Higher flow mode: 10 hours Lower flow mode (ECO mode): 16 hours

Operating Temperature

-4°F to + 122°F (no sudden change)

Operating Humidity Range

95% RH or less (without condensation)

External Dimensions

3.23" (W) x 3.78" (H) x 1.14" (D) (body only)

Weight

4.58 oz

Explosion Proof

Intrinsically safe construction, ATEX/IECEx

Standard Accessories

4" tapered red rubber nozzle, AA alkaline battery, & hydrophobic filters

Optional Accessories

10 ft – 100 ft hose, 10" probe with dust filter

Part Nunber

Description

RK-81-1197

RP-3R Pump For GX-3R

RK-81-1198

RP-3R Pump For GX-3R With 10 ft Hose & 10" Probe

RK-81-1198-20

RP-3R Pump For GX-3R With 20 ft Hose & 10" Probe

RK-81-1198-30

RP-3R Pump For GX-3R With 30 ft Hose & 10" Probe

RK-81-1199

RP-3R Pro Pump For GX-3R Pro

RK-81-1200

RP-3R Pro Pump For GX-3R Pro With 10 ft Hose & 10" Probe

RK-81-1200-20

RP-3R Pro Pump For GX-3R Pro With 20 ft Hose & 10" Probe

Inf Z 50

ne

Differences Between The 3 Operating Modes Of The GX-2012 • "Normal Operating" mode is used for confined space, safety monitoring applications • "Leak Check" mode is used for leak investigation applications • "Bar Hole" mode is used for underground leak checking applications

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Excellent For Gas Line Purge Testing GX-2012 5-Sensor Sample Draw Confined Space Multi-Gas Monitor With CSA Approval Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump. Features

Applications

• Monitors ppm LEL, % Vol. CH4, O2, CO and H2S • 0 - 100% Vol. CH4 option • Auto-ranging display of % LEL and % Vol. • (3) operating modes: normal, leak check, & bar hole • PPM leak detector • Adjustable display ranges • Visual / audible pulses change with gas concentration • CO display in leak check mode • Barhole test mode for underground leak checks • Status indicators: pump active, microprocess or status and battery level • Internal sample drawing pump with up to 50 ft range • Vibration, visual and audible alarms • Automatic backlight during alarms • Bump test and calibration reminder with lock out option • Li-Ion or alkaline battery packs (interchangeable) • Alarm latching or non-latching • High impact, dust and water resistant design • Up to 600 hours of data logging with alarm trends • Snap-logging on demand data recording • TWA and STEL readings with lunch-break mode

• Personal monitoring • Confined space entry • Refineries / petrochemical • Chemical plants • Hazardous material • Water/waste water treatment • Fire services • Mining Kit Includes • GX-2012 monitor • 10" probe • 3.5" rubber nozzle • 10 ft hose • Belt clip • 115/220 VAC adapter for charger • Li-Ion battery pack & 100-240 VAC charger • Quick reference card

Model

GX-2012

Gas Detected

Combustible Gases (Methane (CH4) as standard)

% Vol. Methane (CH4)

Oxygen (O2)

Hydrogen Sulfide (H2S)

Carbon Monoxide (CO)

Detection Principal

Catalytic Combustion

Thermal Conductivity

Galvanic Cell

Detection Range

• 0 ~ 100% LEL • 0 ~ 500/1,000/2,000/ 5,000 ppm

0 ~ 100% Vol.

0 ~ 40% Vol.

0 ~ 100 ppm (optional 0 - 500 ppm)

0 ~ 500 ppm

Accuracy (Whichever Is Greater)

± 5% of reading or ± 2% LEL (LEL mode only)

± 5% of reading or ± 2% of full scale CH4

± 5% O2

± 5% of reading or ± 2 ppm H2S

± 5% of reading or ± 5 ppm CO

Electrochemical Cell

Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter

Sampling Method

Li-Ion battery pack or (3) "AA" Alkaline battery pack (interchangeable)

Power Source

-20°C to +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing

Operating Temp. & Humidity

ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)

Safety Rating

Part Number

Description

Calibration Equipment

RK-72-0292-22-C

GX-2012 4-Gas Detector For LEL/O2/H2S/CO With Li-Ion Battery Pack & 100-240 VAC Charger

• NLB-Z105325PM51 • NLB-8C10 • RK-06-1248RK-03 • NLB-505

*Other configurations are also available

Accessories & Calibration Equipment Part Number

Description

RK-81-SDM2012-01

Single Point Calibration Station For GX-2012 & Gas Tracer With AC Adaptor, Flash Drive, USB Cable & Tubing

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-8C10

Demand Flow Regulator For Cylinders With CGA C-10

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

PC-915-1001

Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)

*Optional RP-3R clip-on sample drawing pump also available

AIR MONITORING

51


AIR MONITORING

Excellent For Gas Line Purge Testing & Detection Of Small Gas Leaks Gas Tracer Confined Space Multi-Gas / Leak Detector Built around high-quality micro-sensor technology, the Gas Tracer is RKI’s smallest personal 5-sensor monitor with a built in sample pump. Features

Applications

• Monitors ppm LEL, % Vol. CH4, O2 and CO • PPM leak detector, detects down to 10 ppm CH4 • "Leak tracker" audible/visual alarm mode for CH4 and CO • 0 - 100% Vol. CH4 option • Auto-ranging display of % LEL and % volume • Barhole test mode • Bump test reminder option • Snap-logging - on demand data recording • Pump pause on demand extends battery life • Status indicators: pump active, microprocessor status and battery level • Internal sample drawing pump with up to 50 ft range • Vibration, visual and audible alarms • Automatic backlight during alarms • Calibration reminder with lock out option • Li-Ion or alkaline battery packs (interchangeable) • Alarm latching or non-latching • High impact protective rubber over molding • Up to 600 hours of data logging with alarm trends • Auto-calibration or single calibration • High dust and water resistance design • TWA and STEL readings with lunch-break mode

• Personal monitoring • Confined space entry • Refineries / petrochemical • Chemical plants • Hazardous material • Water/waste water treatment • Fire services • Mining

Model

Kit Includes • Gas Tracer monitor • 10" probe • 2.5" rubber nozzle • 10 ft hose • Belt clip • 115/220 VAC adapter for charger • Li-Ion battery pack & 100-240 VAC charger • Quick reference card

Gas Tracer

Gas Detected

Combustible Gases (Methane (CH4) as standard)

% Vol. Methane (CH4)

PPM Methane (CH4)

Oxygen (O2)

Carbon Monoxide (CO)

Detection Principal

Catalytic Combustion

Thermal Conductivity

MOS/Catalytic

Galvanic Cell

Electrochemical Cell

Detection Range

0 ~ 100% LEL

0 ~ 100% Vol.

0 ~ 5000 ppm optional 10,000 ppm range version available

0 ~ 40% Vol.

0 ~ 500 ppm

Accuracy (Whichever Is Greater)

± 5% of reading or ± 2% LEL

± 5% of reading or ± 2% of full scale CH4

± 10% of reading or ± 50 ppm CH4

± 5% O2

± 5% of reading or ± 5 ppm CO

Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter

Sampling Method

Li-Ion battery pack or (3) "AA" Alkaline battery pack (interchangeable)

Power Source

-20°C to +50°C (-4°F to 122°F), 0 to 95% RH, non-condensing

Operating Temp. & Humidity

ATEX, TIIS, IECEx, CE, or optionally: c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D Note: Either ATEX (USA and worldwide) or CSA (Canada) version must be specified when ordering.

Safety Rating

Part Number

Description

Calibration Equipment

RK-72-0291-69-C

Gas Tracer 5-Gas Detector For PPM CH4/LEL/% Vol. CH4/O2/CO Base With Li-Ion Battery Pack & 100-240 VAC Charger

• NLB-J1971500PA • NLB-Z1971 • NLB-J197150LM4 • NLB-8C10

• RK-33-2001RK-01 • RK-06-1248RK-03 • NLB-500C

*Other configurations are also available

Accessories & Calibration Equipment

52

Part Number

Description

RK-81-SDM2012-01

Single Point Calibration Station For GX-2012 & Gas Tracer With AC Adaptor, Flash Drive, USB Cable & Tubing

NLB-J1971500PA

Calibration Gas 500 PPM CH4 In Air, 103 Liter Steel Cylinder With CGA C-10

NLB-Z1971

Calibration Gas 100% Vol. CH4, 58 Liter Aluminum Cylinder With CGA C-10

NLB-J197150LM4

Calibration Gas 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 103 Liter Steel Cylinder With CGA C-10

NLB-8C10

Demand Flow Regulator For Cylinders With CGA C-10

RK-33-2001RK-01

6" Humidifier Tube Assembly For Cal Kits With 3/16" Tubing On Ends

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-500C

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 3 Cylinders

PC-915-1001

Black NANUK™ Case 915 With Cubed Foam (Other Colors Available Upon Request)

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Also Available... GX-6000 Benzene Specific Gas Detector Features • 0.01 - 50 ppm with 10.0 eV PID lamp and pre-filter tube • Benzene Select Mode takes timed samples using pre-filter tube • Benzene Filter Tube Holder • Long break through times for Benzene filter tubes • 4 PID options: 10.6 eV (2 ranges), 10.0 eV, and 11.7 eV lamp • Easily switch VOC target gas • Available with both 10.0 & 10.6 PID sensors • Monitor up to 6 gases • 2 smart sensor slots auto recognize PID, IR, and super toxic sensors • Internal sample pump

Inf Z

ne

Contact us at 1-888-287-3732 for more information

Calibration & Accessories

AUTHORIZED RKI SERVICE CENTER

AIR MONITORING

53


AIR MONITORING

Best Seller! GX-6000 Up To 6-Gas, Sample Draw Portable Monitor With Choice Of PID, IR & Super Toxic Sensors The GX-6000 simultaneously monitors up to 6-gases. In addition to the standard 4 confined space gases which include LEL, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. It can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. A benzene-specific version is also available using a pre-filter tube for detecting low levels of benzene.

Model Name Gas Detected

GX-6000 600 VOC’s

Benzene Specific

High Voltage Lamp

PID Sensors

Detection Principal Detection Range

300 VOC’s

0 - 50,000 ppb

0.1 - 50 ppm

Oxygen (O2)

Carbon Monoxide (CO)

Galvanic Cell

0 - 100 ppm

0 - 1000 ppm

Hydrogen Sulfide (H2S)

Electrochemical Cell

0 - 40.0% Vol.

0 - 500 ppm

0 - 100.0 ppm

± 0.5% O2

± 5% of reading or ± 5 ppm CO

± 5% of reading or ± 2 ppm H2S

0 - 6,000 ppm ± 10% of reading, ± 1 digit

Accuracy

Sampling Method Power Source (Configurable) Operating Temp. & Humidity Safety Rating

Applications • Confined space entry • Hazmat response teams • Arson investigation • Remediation site • Perimeter monitoring • Leak detection • Landfill monitoring • Winery tank entry

Kit Includes • GX-6000 monitor • Probe attached with 3 ft teflon lined hose • Tapper nozzle • Belt clip • Hand strap • Rubber boot • Hydrophobic & dust filter • 115/220 VAC adapter for charger • Li-Ion battery pack & 100-240 VAC charger • Quick reference card

AUTHORIZED RKI SERVICE CENTER 54

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Sample draw pump, flow rate 0.45 LPM, 50 foot sample range Li-ion or Alkaline -20°C ~ +50°C (-4°F to 122°F ), 0- 95% RH non condensing Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class: Ex ia IIC T4 Ga Others: CE Marking


Features • Monitors up to 6 gases • Two smart sensor slots auto recognize PID, IR and super toxic sensors • Six operating modes: normal, leak check, benzene select mode, inert, snap log and bar hole • Four PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps • PID library of over 600 VOCs • Benzene specific version • PPM leak check mode

• LEL sensor protection mode • Man-down alarm • Panic alarm, auto display rotation • Peak-bar display • LED Light source • Internal sample pump • Light weight, small, rugged IP-67 design • Li-Ion or alkaline battery packs (interchangeable) • Field replaceable sensors, batteries, filters and pump

AIR MONITORING

Sample Draw with PID, IR, O2, CO, H2S, VOC & Super Toxic Sensor Options

GX-6000 Ammonia (NH3)

Chlorine (Cl2)

Hydrogen Cyanide Nitrogen Dioxide (HCN) (NO2)

Sulfur Dioxide (SO2)

Carbon Dioxide (CO2)

Toxics (Electrochemical Sensors) 0 - 400.0 ppm

0 - 10.00 ppm

0 - 15.0 ppm

0 - 20.00 ppm

Methane (CH4)

Hydrocarbons

Infrared (IR Sensors) 0 - 99.90 ppm

0 - 10,000 ppm 0 - 10.00% Vol.

± 10% of reading or ± 5% of full scale

0 - 100% LEL 0 - 100% Vol.

0 - 100% LEL 0 - 30% Vol.

± 5% of reading or ± 2% of full scale

Hydrocarbons (CH4, std)

Catalytic Combustion 0 - 100% LEL ± 5% of reading or ± 2% LEL

Sample draw pump, flow rate 0.45 LPM, 50 foot sample range Li-ion or Alkaline -20°C ~ +50°C (-4°F to 122°F ), 0- 95% RH non condensing Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class: Ex ia IIC T4 Ga Others: CE Marking

Part Number

Description

Calibration Equipment

RK-72-6ABX-C

GX-6000 For LEL/ O2/H2S/CO/VOCs (0-6,000 ppm PID) With Li-Ion Battery Pack & 100-240 VAC Charger

• NLB-J1055100PA • NLB-Z105325PM51 • NLB-8C10 • RK-06-1248RK-03 • NLB-505

*Other configurations are also available

Accessories & Calibration Equipment Part Number

Description

RK-81-SDM6000-01

SDM-6000 Calibration Station For GX-6000 With Particle Filter, Connection Brackets, SD Card, USB SD Card Reader, Ethernet Cable, USB Cable For PC, 10’ Exhaust Tubing & Single Unit AC Adapter

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-J105100PA

Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10

NLB-8C10

Demand Flow Regulator For Cylinders With CGA C-10

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

PC-920-1001

Black NANUK™ Case 920 With Cubed Foam (Other Colors Available Upon Request)

AIR MONITORING

55


AIR MONITORING

Over 400 Gas Monitoring Configurations EAGLETM Up To 6-Gas Portable Monitor The EAGLETM is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, continuous operation adapters, remote alarms and strobes, and dilution fittings, etc. Applications • Personal monitoring • Confined space entry • Refineries / petrochemical • Chemical plants • Hazardous material • Water/waste water treatment • Fire services • Mining • Line purge testing • Transformer testing • Leak investigation

AUTHORIZED RKI SERVICE CENTER

Kit Includes • EAGLETM monitor • 10" hydrophobic probe (standard gas versions and some super toxic versions only) • 5 ft polyurethane hose (standard gas versions and some super toxic versions only) • Shoulder strap with RKI logo • Internal hydrophobic filter • (4) "D" alkaline batteries

Features • Simultaneous detection of up to 6 different gases • IR Sensors available for CO2, % LEL CH4 or HC, % Vol. CH4 or HC • Wide range of toxic gases • PPM / LEL hydrocarbon detection • CH4 elimination switch for environmental applications • Two alarm levels per channel plus TWA and STEL alarms for toxic channels • Powerful long-life pump up to 125' range with filters • Dual hydrophobic filters (most versions) • Transformer testing version available

Part Number

Description

Calibration Equipment

RK-72-5401RK

EAGLETM For LEL & PPM/O2/CO/H2S

• NLB-Z105325PM51 • NLB-J120815LA** • NLB-8C10 • RK-06-1248RK-03 • NLB-505

*Other configurations are also available **Optional & ONLY used if the customer’s intent is to use the Methane elimination mode

Accessories & Calibration Equipment

56

Part Number

Description

RK-81-SDME2-01

SDM-E2 Calibration For EAGLETM & EAGLETM 2, With AC Adaptor, Flash Drive, USB Cable & Tubing

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-J120815LA

Calibration Gas 15% LEL Hexane In Air, 103 Liter Steel Cyl. With CGA C-10

NLB-8C10

Demand Flow Regulator For Cylinders With CGA C-10

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

RK-49-2150RK-01

Ni-Cad Batteries & 115 VAC Charger For EAGLETM

RK-57-0012RK-01

Factory Installed Data Logging Board For EAGLETM (Part # RK-82-5007RK Also Required)

RK-75-0001RK

Factory Installed External Methane Elimination Switch For EAGLETM

RK-33-0156RK-01

Replacement Hydrophobic Filter Element For EAGLETM & EAGLETM 2 Probe, 5/Pack

PC-925-1001

Black NANUK™ Case 925 With Cubed Foam (Other Colors Available Upon Request)

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Model

EAGLETM

Gas Detected

Detection Range

Hydrocarbons (CH4, std)

0 - 100% LEL

± 5% of reading or ± 2% LEL

0 - 50,000 ppm

± 50 ppm or ± 5% of reading

Accuracy (Whichever Is Greater) Standard Confined Space Gases

Oxygen (O2)

0 - 40% Vol.

± 0.5% O2

Carbon Monoxide (CO)

0 - 500 ppm

± 5% of reading or ± 5 ppm CO

Hydrogen Sulfide (H2S)

0 - 100 ppm

± 5% of reading or ± 2 ppm H2S Super Toxics & Other Gases

Ammonia (NH3)

0 - 75 ppm

Arsine (AsH3)

0 - 1 ppm 0 - 200 ppb

Chlorine (Cl2)

0 - 3 ppm

Chlorine Dioxide (ClO2)

0 - 1 ppm

Fluorine (F2)

0 - 5 ppm

Hydrogen Fluoride (HF)

0 - 9 ppm

Hydrogen Chloride (HCl)

0 - 15 ppm

Hydrogen Cyanide (HCN)

0 - 30 ppm

Hydrogen Peroxide (H2O2)

0 - 3 ppm

Hydrogen Selenide (H2Se)

0 - 0.2 ppm

Hydrogen Sulfide (H2S)

0 - 1 ppm 0 - 30 ppm

Nitrogen Dioxide (NO2)

0 - 15 ppm

Ozone (O3)

0 - 1 ppm

Nitric Oxide (NO)

0 - 100 ppm

Phosphine (PH3)

0 - 1 ppm

Silane (SiH4)

0 - 15 ppm

Sulfur Dioxide (SO2)

0 - 6 ppm

Carbon Dioxide (CO2)

0 - 5,000 ppm 0 - 10,000 ppm 0 - 5% Vol. 0 - 20% Vol. 0 - 60% Vol.

± 10% of reading or ± 5% of full scale

Infrared (IR Sensors)

± 5% of reading or ± 2% of full scale

Methane (CH4)

0 - 100% LEL 0 - 100% Vol.

Isobutane (iC4H10)

0 - 100% LEL 0 - 30% Vol.

Detection Principal

Catalytic Combustion, Electrochemical Cell, Galvanic Cell & Infrared

Sampling Method

Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.

Power Source

(4) Alkaline or Ni-Cad, size "D" batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines.)

Operating Temp. & Humidity

-10°C to 40°C (14°F to 104°F), 0 to 95% RH, non-condensing

Safety Rating

Intrinsically Safe, Class I, Division 1, Groups A, B, C, D. CSA (C / US) and UL classified (most versions)

AIR MONITORING

57


AIR MONITORING

Soaring To New Heights! The Legacy Continues With The EAGLETM 2 EagleTM 2 Up To 6-Gas Portable Monitor With Choice Of PID The EAGLETM 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO. The EAGLETM 2 available features include a PID sensor for detecting high or low ppm levels (0 - 50 ppm & 0 - 2,000 ppm) of VOC gases; % Vol. capability for CH4 and H2 using a TC (thermal conductivity) sensor; PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % Vol.), CH4 or hydrocarbons in LEL and % Vol. ranges; CH4 elimination feature for environmental applications; and a variety of super toxic gases. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, etc.

Applications

Kit Includes

• Personal monitoring • VOC monitoring • Confined space entry • Refineries / petrochemical • Chemical plants • Hazardous material • Water/waste water treatment • Fire services • Mining • Line purge testing • Transformer testing • Leak investigation

• EAGLETM 2 monitor • 10" hydrophobic probe without particle filter, with metal fittings (used for EAGLETM 2 with PID versions only) • 5 ft teflon lined hose with fittings (used for EAGLETM 2 with PID versions only) • Shoulder strap with RKI logo • Internal hydrophobic filter • (4) "C" alkaline battery

Features • Simultaneous detection of up to 6 different gases • PPM, % LEL, or % Vol. auto-ranging combustible detection • Specialty Sensors • PID (Photoionization Detector): low or high range for VOC detection, fence electrode technology for • humidity and contamination resistance • Infrared (IR): CO2, % LEL CH4, % Vol. CH4, % LEL HC, % Vol. HC • Thermal Conductivity (TC): % Vol. H2, % Vol. CH4 • Smart toxic, plug and play sensors: NH3, AsH3, Cl2, HCN, PH3, & SO2 • Hydrogen specific LEL / ppm sensor

Part Number

Description

RK-725-101-P2

EAGLE

TM

• Data logging standard • CH4 elimination for environmental use • Low flow pump shut off and alarm • Two alarm levels per channel plus TWA and STEL alarms for toxic channels • Powerful long-life pump up to 125’ range • Internal hydrophobic dust filter • External probe with hydrophobic filter • Password protection • Multilingual (5 languages) • Ergonomic RFI / EMI / chemical / weather resistant enclosure

2 For LEL & PPM/ O2/CO/H2S/VOCs (0 - 2,000 ppm PID)

*Other configurations are also available

AUTHORIZED RKI SERVICE CENTER Calibration Equipment • NLB-Z105325PM51 • NLB-J1055100PA • NLB-8C10 • RK-06-1248RK-03 • NLB-505

Accessories & Calibration Equipment

58

Part Number

Description

RK-81-SDME2-01

SDM-E2 Calibration For EAGLETM & EAGLETM 2, With AC Adaptor, Flash Drive, USB Cable & Tubing

NLB-Z105325PM51

Calibration Gas 25 PPM H2S / 50 PPM CO / 2.5% CH4 (50% LEL) / 12% O2 In N2, 58 Liter Aluminum Cylinder With CGA C-10

NLB-J105100PA

Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10

NLB-8C10

Demand Flow Regulator For Cylinders With CGA C-10

RK-06-1248RK-03

3/16" O.D. x 5/16" I.D. Polyurethane Calibration Tubing, 3 ft

NLB-505

Case For 58 / 103 / 116 Liter Aluminum Cylinders, Holds 2 Cylinders

RK-49-2175RK-01

Factory Installed 100-240 VAC Battery Charger With (4) "C" NiMH Batteries For EAGLETM 2

RK-33-0156RK-01

Replacement Hydrophobic Filter Element For EAGLETM & EAGLETM 2 Probe, 5/Pack

PC-925-1001

Black NANUK™ Case 925 With Cubed Foam (Other Colors Available Upon Request)

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Model

EAGLETM 2

Gas Detected

Detection Range

Hydrocarbons (CH4, std)

0 - 100% LEL

Accuracy (Whichever Is Greater) Standard Confined Space Gases

0 - 5% Vol. (CH4)

± 5% of reading or ± 2% LEL

0 - 50,000 ppm

± 50 ppm or ± 5% of reading

Oxygen (O2)

0 - 40% Vol.

± 0.5% O2

Carbon Monoxide (CO)

0 - 500 ppm

± 5% of reading or ± 5 ppm CO

Hydrogen Sulfide (H2S)

0 - 100 ppm

± 5% of reading or ± 2 ppm H2S Toxics

Ammonia (NH3)

0 - 75 ppm

Arsine (AsH3)

0 - 1.5 ppm

Chlorine (Cl2)

0 - 3 ppm

Hydrogen Cyanide (HCN)

0 - 15 ppm

Phosphine (PH3)

0 - 1 ppm

Sulfur Dioxide (SO2)

0 - 6 ppm

± 10% of reading or ± 5% of full scale

Infrared (IR Sensors) Carbon Dioxide (CO2)

0 - 10,000 ppm 0 - 5% Vol. 0 - 60% Vol.

Methane (CH4)

0 - 100% LEL/0 - 100% Vol.

Hydrocarbons

0 - 100% LEL/0 - 30% Vol.

± 5% of reading or ± 2% of full scale

PID Sensors VOC

0 - 2,000 ppm 0 - 50 ppm

— TC Sensors

Methane (CH4)

0 - 100% Vol.

Hydrogen (H2)

0 - 10% Vol. 0 - 100% Vol.

Hydrogen (H2)

0 - 100% LEL 0 - 40,000 ppm

Detection Principal

Catalytic Combustion, Electrochemical Eell, Galvanic Cell, Infrared, Photoionization Detector & Thermal Conductivity

Sampling Method

Powerful, long-life internal pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.

Power Source

(4) alkaline or NiMH, size "C" batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines.)

Operating Temp. & Humidity

-20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing

Safety Rating

Intrinsically Safe, Class I, Groups A, B, C, D. Approvals: CSA / CE

± 5% of reading or ± 2% of full scale Hydrogen Specific

* The EAGLE

TM

Inf Z

± 5% of reading or ± 2% of full scale

2 can be configured with up to 6 gas sensors from the above list

ne

The Major differences

EAGLETM 1 • Ability to detect for more different gases with regard to toxic inorganic compounds, using the large toxic, electrochemical sensors • Limited as to what sensor configurations it can do, especially when 5 or 6 sensors are considered • Datalogging is no longer supported • Longer run time using "D" size batteries (to access the NiCad rechargeable batteries, you must lift off the top case) • Available for approx. 2 more years

Between The EAGLETM 1 & The EAGLETM 2

VS

EAGLETM 2 • PID capability • Thermal Conductivity sensor capability, % Vol. as an option to the IR sensors • Hydrogen specific capability for the % LEL sensor • Datalogging capabilities is supported • Shorter run time using "C" size batteries (exterior Alkaline or NiMH battery pack)

AIR MONITORING

59


AIR MONITORING

The World’s Smallest & Lightest Personal VOC Detector Cub Personal VOC Detector The Cub personal PID monitor accurately detects volatile organic (VOC) and total aromatic compounds (TAC). With market leading parts-per-billion (ppb) sensitivity, Cub gives an early warning of hazardous gases, including benzene, before they reach levels which are harmful. Also available is the CubTAC ppm variant with 10.0 eV lamp for the detection of total aromatic compounds (TACs), including benzene.

Applications • Industrial hygiene • Chemical and petrochemical plants • Oil & gas • Pharmaceuticals • Health & safety • Hazardous materials • First response • Environmental

Features • Available in three distinct variants: ppm, ppb and TAC mode • ppm or ppb Cub detects a wide range of over 480 VOCs • CubTAC detects total aromatic compounds (TACs) down to ppb levels • Detection range: • Cub ppm model: 0.1 - 5,000 ppm • Cub ppb model: 1 ppb - 5,000 ppm • CubTAC model: 10 ppb - 5,000 ppm • Optional software upgrade from ppm to ppb • Lamp: • Cub ppm & ppb model: 10.6 eV • CubTAC model: 10.0 eV • Humidity resistance technology • Data logging 30,000 readings • Multi-logging including full list of gases selectable from PC software • LED audio & vibrate alarm • Pre-programmed TWA & STEL alarm* (only available for ppb model) • Work exposure alarm levels • Three CUBDoc docking stations available: • Charge dock only • Charge and USB communication dock • Charge, USB communication and calibration dock • Certifications: ATEX, IECEx, CSA - Intrinsically Safe

60

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Kit Includes • Cub instrument • Docking station • Accessory kit • Stack removal tool • Mains cable • USB cable • Remote calibration adaptor • Li-Ion rechargeable battery • Quick start guide • Calibration certificate


Part Number

Description

Detection Range

PID Lamp

Fence Electrode

Calibration Equipment

IS-CKPSXCAX-CH

Cub PPM With Charge Docking Station Only

0.1 - 5,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-CKPSXCAX-WD

Cub PPM With Charge & USB Communication Docking Station

0.1 - 5,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-CKPSXCAX-WC

Cub PPM With Charge, USB Communication & Calibration Docking Station

0.1 - 5,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-CKBSXCAX-CH

Cub PPB With Charge Docking Station Only

1 ppb - 5,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H105510PA* • NLB-H1055100PA** • NLB-414 or NLB-417

IS-CKBSXCAX-WD

Cub PPB With Charge & USB Communication Docking Station

1 ppb - 5,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H105510PA* • NLB-H1055100PA** • NLB-414 or NLB-417

IS-CKBSXCAX-WC

Cub PPB With Charge, USB Communication & Calibration Docking Station

1 ppb - 5,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H105510PA* • NLB-H1055100PA** • NLB-414 or NLB-417

IS-CKTSXCAX-CH

CubTAC With Charge Docking Station Only

10 ppb - 5,000 ppm

10.0 eV

White With Gold Spot Fence Electrode Stack

• NLB-Z11145PA • NLB-514 or NLB-517

IS-CKTSXCAX-WD

CubTAC With Charge & USB Communication Docking Station

10 ppb - 5,000 ppm

10.6 eV

White With Gold Spot Fence Electrode Stack

• NLB-Z11145PA • NLB-514 or NLB-517

IS-CKTSXCAX-WC

CubTAC With Charge, USB Communication & Calibration Docking Station

10 ppb - 5,000 ppm

10.6 eV

White With Gold Spot Fence Electrode Stack

• NLB-Z11145PA • NLB-514 or NLB-517

AIR MONITORING

AUTHORIZED ION SERVICE CENTER

* Used to calibrate for ppb measurements ** Used to calibrate for ppm measurements

Accessories & Calibration Equipment Part Number

Description

IS-CUBUPG-M2B

Cub Software Upgrade From PPM To PPB

IS-LA4TM600

10.6 eV PID Lamp

IS-LA4TS600

10.0 eV PID Lamp

IS-A-846267

White Fence Electrode Stack

IS-A-846417

White With Gold Spot Fence Electrode Stack

IS-871026

PTFE Filter Membrane, Each

IS-A-31063

PID Lamp Cleaning Kit

IS-871200

Calibration Cup

NLB-H1055100PA

Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600

NLB-H105510PA

Calibration Gas 10 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600

NLB-Z11145PA

Calibration Gas 5 PPM Benzene In Air, 58 Liter Aluminum Cyl. With CGA C-10

NLB-414

0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-514

0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

NLB-517

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

*Other accessories also available

AIR MONITORING

61


AIR MONITORING

TIGER

COMPARISON CHART HANDHELD VOC DETECTOR

Inf Z

62

ne

Model

Tiger LT

Tiger

Tiger Select

General VOC Detection Range

0-5000 ppm

0-20,000 ppm

0-20,000 ppm

VOC Sensitivity

PPM

PPM or PPB

PPM or PPB

Lamp Style

10.6eV

10.0eV, 10.6eV, 11.7eV

10.0eV

Intermal Gas Table

RF Only

Data Logging

Push to Log

Continuous

Continuous

Data Points

80,000 points

120,000 points

120,000 points

Zones

128

128

128

Health and Satety

X

Benzene Mode

X

X

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

AUTHORIZED ION SERVICE CENTER


AIR MONITORING

Low Cost VOC Detection With Market Leading Accuracy TigerLT Handheld VOC Detector The TigerLT accurately detects volatile organic compounds (VOCs) from 0 - 5,000 ppm with a 0.1 ppm minimum sensitivity, has the fastest response time on the market of just two seconds, and is as quick to clear down. Its revolutionary, patented PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time. Applications

Standard Kit Includes

• Environmental monitoring • Soil contamination detection • VOCs in landfill • IAQ measuring industrial volatiles • Health & safety • Confined space entry • First response (screening) • Wing tank entry • VOC leak detection • Fumigation gases • Fugitive emissions • Medical gases in hospitals • Fire and Arson Investigation

• TigerLT instrument with rubber boot • PTFE filter disc (dust filter) • Removal tool for MiniPID Stack • Sample cleaning compound assembly • Cleaning buds • USB cable • Li-Ion rechargeable battery • Battery charger and mains adaptor • Lightweight transport case

Features • Detection range: 0.1 - 5,000 ppm • Lamp: • 10.6 eV (standard) • 10.0 eV and 11.7 eV (optional also available) • Patented humidity resistance technology to 99% RH – no compensation needed • Push-to-log data logging stores up to 80,000 data points in up to 128 user selectable zones • User selectable response factors for direct concentration readout • Flashing LED & audible alarm • Selectable vibrating alarm • Factory calibration mode available • Certifications: ATEX, IECEx, CSA - Intrinsically Safe

Premium Kit Includes • TigerLT instrument with rubber boot • Lanyard (wrist strap) • PTFE filter disc (dust filter) • Carbon zero filter assembly • Sensor seal (coated) • Removal tool for MiniPID Stack • Sample cleaning compound assembly • Cleaning buds • Calibration adaptor • USB cable • Li-Ion rechargeable battery • Battery charger and mains adaptor • Explorer transport case

Part Number

Description

Detection Range

PID Lamp

Fence Electrode

Calibration Equipment

IS-PTLSLBMR-0000

Tiger With Standard Kit

0.1 - 5,000 ppm

10.6 eV

Orange Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-PTLSLBMPP-0000

TigerLT With Premium Kit

0.1 - 5,000 ppm

10.6 eV

Orange Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

LT

Accessories & Calibration Equipment Part Number

Description

IS-LA4TM600

10.6 eV PID Lamp

IS-A-846496

Orange Fence Electrode Stack

IS-A-861632

Premium PTFE Filters, 10/Pack

NLB-H1055100PA

Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600

NLB-414

0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

*Other accessories also available

AIR MONITORING

63


AIR MONITORING

Handheld Humidity-Resistant VOC Detector Tiger Handheld VOC Detector The Tiger provides a dynamic detection range of 0 - 20,000 parts per million (ppm) with a minimum sensitivity of 0.001 ppm (1 ppb), offering the widest measurement range of any other volatile organic compound (VOC) detector on the market. Its revolutionary, PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time. Applications

Features

• Environmental monitoring • Soil contamination detection • VOCs in landfill • IAQ measuring industrial volatiles • Leakage in fuel & chemical storage • Health & safety • STEL & TWA monitoring • Confined space entry • First response (screening) • Wing tank entry • VOC leak detection • Fumigation gases • Fugitive emissions • Medical gases in hospitals • Fire and Arson Investigation

• Available in two distinct variants: ppm and ppb • Detection range: • Tiger ppm model: 0.1 - 20,000 ppm • Tiger ppb model: 1 ppb - 20,000 ppm • Optional software upgrade from ppm to ppb • Lamp: • Tiger ppm and Tiger ppb models: 10.6 eV (standard) • 10.0 eV and 11.7 eV (optional also available) • Patented humidity resistance technology to 99% RH – no compensation needed • Push-to-log and multi-logging stores up to 120,000 data points including date/time • Internal gas table with over 700 VOCs and toxic compounds • Flashing LED & audible alarm • Selectable vibrating alarm • Pre-programmed TWA & STEL alarm* (only available for ppb model) • Factory calibration mode available • Certifications: ATEX, IECEx, CSA - Intrinsically Safe

Kit Includes • Tiger instrument with rubber boot • Lanyard (wrist strap) • PID lamp cleaning kit • Removal tool MiniPID stack • Main adapter • USB cable • PTFE filter disc (dust filter)

• Carbon zero filter assembly • Li-Ion rechargeable battery • Battery charger • Calibration adaptor • Quick start guide • Explorer transport case

Part Number

Description

Model

Detection Range

PID Lamp

Fence Electrode

Calibration Equipment

IS-PTXSLBMPP-0005

Tiger PPM/H&S/ Data Logging

PPM

0.1 - 20,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-PTXSLBMPP-0007

Tiger PPM/H&S/ Data Logging

PPB

1 ppb - 20,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H105510PA* • NLB-H1055100PA** • NLB-414 or NLB-417

* Used to calibrate for ppb measurements ** Used to calibrate for ppm measurements

Accessories & Calibration Equipment Part Number

Description

IS-LA4TM600

10.6 eV PID Lamp

IS-LA4TS600

10.0 eV PID Lamp

IS-A-846267

White Fence Electrode Stack

IS-A-846417

White With Gold Spot Fence Electrode Stack

IS-A-861632

Premium PTFE Filters, 10/Pack

NLB-H105510PA

Calibration Gas 10 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600

NLB-H1055100PA

Calibration Gas 100 PPM Isobutylene In Air, 34 Liter Steel Cylinder With CGA 600

NLB-414

0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

*Other accessories also available

64

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Instant VOC Detection For Fire & Arson Investigation TigerLT & Tiger Handheld VOC Detector With Fire Investigation Kit The ION Science fire investigation kit with Tiger or TigerLT PID has been specifically designed to provide you with all the tools for a convenient, easy-to-use solution for the detection of volatile organic compounds (VOCs) within fire and arson investigation applications. Both models incorporate Ion Science’s marketleading PID technology with patented fence electrode system. The advanced three-electrode format ensures increased resistance to humidity and contamination for ultimate reliability and accuracy in the field, as well as reduced drift issues and extended run time.

Kit Includes • TigerLT or Tiger instrument with rubber boot • 1 m flexi probe • Bump test pen • (10) Spare PTFE filters • Exhaust barb which can be connected to a collection bag • "AA" Tiger battery pack for emergency power source • Charging cradle & travel charge adaptor • Quick start guide • Rugged carry case

Part Number

Description

Detection Range

PID Lamp

Fence Electrode

Calibration Equipment

IS-PTLSRBMP-0000

Tiger With Fire Investigation Kit

0.1 - 5,000 ppm

10.6 eV

Orange Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-PTXSRBMP-0004

Tiger PPM/Data Logging With Fire Investigation Kit

0.1 - 20,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H1055100PA • NLB-414 or NLB-417

IS-PTXSRBMP-0006

Tiger PPB/Data Logging With Fire Investigation Kit

1 ppb - 20,000 ppm

10.6 eV

White Fence Electrode Stack

• NLB-H105510PA* • NLB-H1055100PA** • NLB-414 or NLB-417

LT

* Used to calibrate for ppb measurements ** Used to calibrate for ppm measurements

Accessories & Calibration Equipment Part Number

Description

IS-LA4TM600

10.0 eV PID Lamp

IS-A-846267

White Fence Electrode Stack

IS-A-846417

White With Gold Spot Fence Electrode Stack

IS-A-861632

Premium PTFE Filters, 10/Pack

NLB-H105510PA

Calibration Gas 10 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10

NLB-H1055100PA

Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10

NLB-414

0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

NLB-417

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA 600

*Other accessories also available

AIR MONITORING

65


AIR MONITORING

Benzene & Total Aromatic Compound (TAC) Detection In One Instrument Tiger Select Handheld VOC & Benzene Detector The Tiger Select is a revolutionary hand-held gas detector for the rapid, accurate detection of benzene and Total Aromatic Compounds (TACs). Utilizing the high output Ion Science 10.0 eV detection system, a reading for TACs is seen immediately on start-up. Should aromatics be detected, an ION Science benzene pre-filter tube can be easily attached to ensure fast detection and selective measurement of benzene. Its revolutionary, PID sensor technology with humidity resistance and anti-contamination design provide market leading accuracy and run-time.

Applications • Confined space entry • Pre-screening during refinery and plant maintenance • Marine spill response • Refinery down-stream monitoring • Hazardous material response • Total aromatic compounds (TACs) • Detection at loading docks and barge operations

AUTHORIZED ION SERVICE CENTER

Features • Available in two distinct variants: ppm and ppb • Selectively detects benzene with benzene pre-filter tubes • Detection range: • Tiger Select ppm model: 0.1 ppm - 20,000 ppm (standard mode: 0.1 - 20,000 ppm, TAC mode: 0.01 - 20,000 ppm and tube mode: 0.001 - 200 ppm) • Tiger ppb model: 0.001 ppm - 20,000 ppm (standard mode: 0.001 - 20,000 ppm TAC mode: 0.001 - 20,000 ppm and tube mode: 0.001 - 200 ppm) • Three available modes to choose from: basic mode, advanced mode and ask mode • Optional software upgrade from ppm to ppb • Lamp: 10.0 eV • A 10.6 eV lamp can easily be installed for the detection of a wide range of VOCs • Patented humidity resistance technology to 99% RH – no compensation needed • Push-to-log and multi-logging stores > 120,000 data points including date/time • Internal gas table with over 700 VOCs and toxic compounds • Flashing LEDs “amber” (low alarm) and “red” (high alarm) • Audible sounder vibration on alarm • Pre-programmed TWA & STEL alarm* (only available for ppb model) • Factory calibration mode available • Certifications: ATEX, IECEx, CSA - Intrinsically Safe

RAPIDLY DETECTS BENZENE & TOTAL AROMATIC COMPOUNDS (TACs) PROVIDING THE MOST ACCURATE, RELIABLE DATA AVAILABLE. 66

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM


AIR MONITORING

Kit Includes • Tiger Select instrument with rubber boot • Benzene pre-filter tube probe • Probe tube (60 mm) • (10) Benzene pre-filter tubes • Benzene pre-filter tube opener • Lanyard (wrist strap) • PID lamp cleaning kit • Removal tool MiniPID stack • Mains adapter • USB Cable • PTFE filter disc (dust filter) • Carbon zero filter assembly • Sensor seal (coated) • Sample cleaning compound assembly • Li-Ion rechargeable battery • Battery charger • Calibration adaptor • Quick start guide • Explorer transport case

Part Number

Description

Model

Detection Range

PID Lamp

Fence Electrode

Calibration Equipment

IS-PTXSLBMPP-0517

Tiger Select Benzene/PPM/ H&S/Data Logging

PPM

0.1 - 20,000 ppm

10.0 eV

White Fence Electrode Stack With Dot & Glass Like Window

• NLB-J1055100PA • NLB-Z11145PA • NLB-514 or NLB-517

IS-PTXSLBMPP-0519

Tiger Select Benzene/PPB/ H&S/Data Logging

PPB

1 ppb - 20,000 ppm

10.0 eV

White Fence Electrode Stack With Dot & Glass Like Window

• NLB-J105510PA* • NLB-J1055100PA** • NLB-Z11145PA • NLB-514 or NLB-517

* Used to calibrate for ppb measurements **Used to calibrate for ppm measurements

Accessories & Calibration Equipment Part Number

Description

IS-LA4TS600

10.0 eV PID Lamp

IS-LA4TM600

10.0 eV PID Lamp

IS-A-846267

White Fence Electrode Stack

IS-A-846417

White With Gold Spot Fence Electrode Stack

IS-A-861632

Premium PTFE Filters, 10/Pack

NLB-H105510PA

Calibration Gas 10 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10

NLB-H1055100PA

Calibration Gas 100 PPM Isobutylene In Air, 103 Liter Aluminum Cylinder With CGA C-10

NLB-Z11145PA

Calibration Gas 5 PPM Benzene In Air, 58 Liter Aluminum Cyl. With CGA C-10

NLB-514

0.3 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

NLB-517

0.5 LPM Regulator With Gauge & Knob For Cylinders With CGA C-10

*Other accessories also available

AIR MONITORING

67


AIR MONITORING

Also Available... Fixed Systems Controllers

Beacon 110

Beacon 410A

Beacon 200

Beacon 800

Detector Heads

Direct Conect

S2

M2A

GD-70D

EC-600

OX-600

Specialty Portable Monitors

04 Series

68

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

EC-600

Beacon 800

Beacon 800


AIR MONITORING

Fixed Systems VOC Detectors

Falco Diffused

Falco Pumped

TVOC2

Leak Detectors

Titan

Mercury Vapor Detector

SF6 Leakmate

YOUR ONE

Buy

MVI

GasCheck G & GasCheck Tesla

Rent

SHOP

Calibrate

Repair AIR MONITORING

69


AIR ODOUR CONTROL

Odour Destroyer & Neutralizer Aquakem™ Odour Skunk™ Odour SkunkTM is a plant-based product that eliminates nasty odours at the source. While many products only mask offensive odours with strong fragrances, Odour SkunkTM will neutralize them. Features

Applications • Residential • Commercial • Industrial • Wastewater

• Chemical odor control • Food processing • Sports • And many more…

• Non irritating • Captures and neutralizes odours • Available without fragrance (minimum • Non-toxic quantities required) • Biodegradable

Part Number

Description

Format

Size

10610-500ML

Aquakem™ Odour Skunk™

Bottle

500 ml

10610-1L

Aquakem™ Odour Skunk™

Bottle

1L

10610-3.6L

Aquakem™ Odour Skunk™

Bottle

3.6 L

10610-20L

Aquakem™ Odour Skunk™

Pail

20 L

10610-204L

Aquakem™ Odour Skunk™

Drum

204 L

10610-1000L

Aquakem™ Odour Skunk™

Tote

1000 L

Removal of odours, gaseous or VOC particulates Sampson™ Odour Removal Pleated Air Filters Sampson™ odour removal carbon pleated filters are designed for the control of intermittent odour problems. This filter can also be a low cost method to verify the potential effectiveness of carbon for controlling an odor problem. Features • Wide range of configurations and sizes available • Available in 1", 2" and 4" depths • MERV 5, 6 • Carbon enhanced pleated filter for odor removal • Can be easily adapted to existing HVAC systems

Applications • Office buildings • Hospitals • Airports • Food courts • Manufacturing facilities Part Number

Description

Nominal Size

Actual Size

Qty/Box

DF-15840

Sampson Odour Removal Pleated Air Filter

20" H x 20" W x 1" D

19 ½" H x 19 ½" W x ¾" D

12

DF-15848

SampsonTM Odour Removal Pleated Air Filter

20" H x 20" W x 2" D

19 ½" H x 19 ½" W x 1 ¾" D

12

DF-17081

Sampson Odour Removal Pleated Air Filter

20" H x 20" W x 4" D

19 ½" H x 19 ½" W x 3 ¾" D

12

TM

TM

*Other sizes also available

Cannabis Odour Control Media CannaSorber™ ERE’s special blend air phase media specifically designed to treat odours from cannabis. Applications • Curing/drying rooms • Cutting/deflowering rooms • Extraction and packaging rooms

70

Features • Proprietary blend of selective media for odour and VOC • Adsorbs terpenoids • Adsorbs terpenes • Adsorbs VOCs • Has a capacity of up to 60% of its own weight • Particle size: 4 x 8 US mesh • CCl4 activity min. (ASTM D-3467): 60 • Proprietary blend active ingredient, % wt. min.: 6.0 • Bulk Density lb/ft3: 39 • Bacteria mold controlled media

Part Number

Description

Quantity

BCS-408-CANNA

CannaSorber

TM

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

40 lbs Bag/Container


Features • High Capacity (MERV 10) • Available in 1”, 2” & 4” depths • 100% synthetic pleated media achieves exceptionally high levels of efficiency • Does not rely on electrostatic charge • Low resistance to air flow means minimal energy costs • Moisture resistant and will not promote microbial growth • Excellent pre-filter for higher efficiency air filters • Effectively removes airborne irritants • Protects cooling coils & ductwork of HVAC system Applications • Prefilter for high efficiency filters • Office and retail • Manufacturing and distribution • Government and education facilities • Doctor offices, assisted living facilities and hospitals • Hotels and airports • Single and multi-family housing

Part Number DF-10438 DF-10447 DF-10489 DF-10448 DF-10456 DF-10460 DF-10462 DF-10463 DF-10466 DF-10467 DF-10469 DF-10471

Description SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter SampsonTM HVAC Pleated Air Filter

Nominal Size 12" H x 20" W x 1" D 20" H x 20" W x 1" D 20" H x 24" W x 1" D 20" H x 25" W x 1" D 16" H x 20" W x 2" D 20" H x 20" W x 2" D 20" H x 25" W x 2" D 24" H x 24" W x 2" D 16" H x 20" W x 4" D 16" H x 25" W x 4" D 20" H x 20" W x 4" D 20" H x 25" W x 4" D

Actual Size 11 ½" H x 19 ½" W x ¾" D 19 ½" H x 19 ½" W x ¾" D 19 ½" H x 23 ½" W x ¾" D 19 ½" H x 24 ½" W x ¾" D 15 ½" H x 19 ½" W x 1 ¾" D 19 ½" H x 19 ½" W x 1 ¾" D 19 ½" H x 24 ½" W x 1 ¾" D 23 ⅜" H x 23 ⅜" W x 1 ¾" D 5 ½" H x 19 ½" W x 3 ¾" D 15 ½" H x 24 ½" W x 3 ¾" D 19 ½" H x 19 ½" W x 3 ¾" D 19 ½" H x 24 ½" W x 3 ¾" D

AIR FILTRATION/TREATMENT

SampsonTM HVAC Pleated Filters

Qty/Box 12 12 12 12 12 12 12 12 6 6 6 6

* Contact customer service for additional sizes and information

Inf Z

Available Air Filters For Many Applications

ne

• Commercial / Industrial • Health Care / Government Facilities • Schools / Universities • Aerospace • Hospitals • Cleanrooms

• Food manufacturing • Chemical • Pharmaceutical • Laboratories • Hotels • Desert / Marine Installations

AIR FILTR ATION/ TRE ATMENT

71


AIR FILTRATION/TREATMENT

UltraSorber-BCTM The UltraSorber-BCTM activated carbon manufactured from selected grades of bituminous coal ideally suited for VOC gas adsorption. possesses both a high surface area and a large internal pore volume. These properties give the carbon not only high VOC adsorption capacities, but also highly retentive for retaining and preventing the desorption of previously adsorbed organic compounds. Being manufactured from high rank coals results in an inherently low ash content, making these carbons ideally suited for critical gas phase adsorption applications. Features • Specifically manufactured from select grades of bituminous coal • Excellent for applications from general odour abatement to solvent adsorption and recovery • High surface area and broad pore structure • Less frequent changeouts = cost effective • Lower pressure drops • Packaged in bags, totes, and super sacs Applications • Solvent recovery operations • Chemical process applications • VOC control from air strippers, soil vapor extraction and air sparge systems • Control of tank vent emissions • HVAC • Odor control • As a substrate for odor control carbon manufacture and as a catalyst support Part Number BC-410 BC-406 BC-608 BC-710

Mesh 4 x 10 4x6 6x8 7 x 10

CCl4 60% 60 - 65% 62 - 67% 62 - 72%

Density 0.40 - 0.46 g/cc 0.44 - 0.49 g/cc 0.48-0.52 g/cc 0.44 - 0.52 g/cc

Hardness 90 - 94% 95% 95 - 97% 95 - 97%

Ash 6 - 10% 8 - 10% 8 - 10% 8 - 10%

Iodine 1000 mg/g 1000 mg/g 1000 mg/g 1000 - 1050 mg/g

Surface Area 1000 - 1100 m2/g 1150 m2/g 1100 - 1200 m2/g 1100 - 1250 m2/g

UltraSorber-CNSTM The UltraSorber-CNSTM is a high activity, granular activated carbon manufactured from selected grades of coconut shell. The granular shape of this carbon maximizes its geometric surface area, significantly increasing surface and pore diffusion rates and thereby increasing its effectiveness for the adsorption of VOCs with a short contact time. The high surface area and predominately microporous pore size distribution further enhance the effectiveness of this coconut shell based carbon. Features • Specifically manufactured from coconut shells • Long life expectancy and removal efficiency • Excellent hardness • High surface area and micropore structure • Less carbon changeouts, less dust and fines • High adsorption capacity, lower pre-soak times, readily wettable • Packaged in bags, totes, and super sacs Applications • Chemical process applications • VOC control from air strippers, soil vapor extraction and air sparge systems • Control of tank vent emissions • HVAC • Odor control • Solvent recovery of low boiling point solvents • Use as a catalyst/catalyst support Part Number CNS-612 CNS-185

72

Mesh 6 x 12 4x8

CCl4 60 - 65% 55%

Density 0.48 - 0.55 g/cc 0.48 - 0.54 g/cc

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Hardness 96 - 98% 90 - 95%

Ash 5% 2.5%

Iodine 1100 - 1200 mg/g 1050 mg/g

Surface Area 1150 - 1250 m2/g 1100 - 1250 m2/g


UltraSorberTM AMMO-CarbTM is coal based activated carbon in pelletized or extruded form. The amount of phosphoric impregnation shall be no less than 7% by weight on the media. UltraSorberTM AMMO-CarbTM is designed for vapor phase applications.

Features • High quality carbon • Extraordinary surface area • Fine pore structure • High density • Superior hardness • Sold in bags, drums, and super sacs Applications

Part Number Mesh AMMO-Carb 4 mm

Density Hardness Iodine Moisture 1100 – 1200 mg/gm 3 % 36-38 lb/ft3 98 %

• Paper industry • Food industry • Biogas industry • Process and wastewater treatment industry

Contaminants Removed • Ammonia • Urea

UltraSorberTM KOH-CarbTM

AIR FILTRATION/TREATMENT

UltraSorberTM AMMO-CarbTM

The UltrasorberTM KOH-CarbTM is highly active coal based pelletized carbon impregnated with potassium hydroxide. The coal based activated carbon is manufactured for vapor phase applications. Features • Hydrogen sulfide removal capacity of 0.10 g/cc • Impregnated with potassium hydroxide to target acidic gases • Carbon tetrachloride activity of no less than 60% • Sold in bags, drums, and super sacs Applications

Contaminants Removed

• Chemical processing • Air stripper off-gas VOC removal • Tank or sump air vents • General HVAC units • API separator vents

• Hydrogen Sulfide • Sulfur Dioxide • Nitrogen Oxide

Part Number KOH-Carb

Mesh 4 mm

CCI4 60 %

Density 0.56-0.58 g/cc

Hardness 95%

Pressure Drop 1.5 @ velocity 60 ft/min-ins wg/ft

UltraSorberTM VPP-CarbTM The UltraSorberTM VPP-CarbTM uses reactive chemistry to oxidize various pollutants. The UltrasorberTM VPP-Carb is zeolite impregnated with 6% potassium permanganate (KMnO4). Its’ high impregnated level of KMnO4 and insignificant dusting attributes make it an ideal media for gas phase filtration. The media is loaded in tanks, exhaust systems, soil vapor extraction (SVE) systems, air filtration trays and modules.

Features • Sold in bags, drums, and super sacs Applications

Part Number VPP-Carb

Mesh 4x6

Density 60-62 lb/ft3

Hardness 95%

• Fresh fruit and vegetable transportation • Refineries • Pulp and paper mills • Ground water remediation • Wastewater treatment

Contaminants Removed • Dichloroethylene (DCE) • Trichloroethylene (TCE) • Hydrogen Sulfide • Mercaptans • Acid gases • Vinyl Chloride • Common odors • Aldehydes • Ethylene • Amines • Chlorinated solvents

AIR FILTR ATION/ TRE ATMENT

73


AIR FILTRATION/TREATMENT

UltraSorberTM MER-CarbTM The UltraSorberTM MER-CarbTM is highly active sulfurized granular activated carbon (GAC) manufactured via high temperature steam activation from selected grades of coconut shell. The MerCarbTM is used in vapor phase applications. Features • Impregnated with 10% sulfur content by weight • Can be loaded in tanks, exhaust systems, general HVAC systems, deep bed scrubbers, etc. • Sold in bags, drums, and super sacs

Applications • Manufacturing facilities • Semiconductor facilities • Refineries

Part Number MER-Carb

Mesh 4 x 10

Density 36-38 lb/ft3

Hardness Iodine 95% 1000 – 1050 mg/g

Contaminants Removed • Mercury

Ash 8-10%

UltraSorberTM Voc-CarbTM The UltraSorberTM Voc-CarbTM is a blend of UltraSorber-BCTM & VPP-CarbTM and is commonly used to remove volatile organic compounds (VOC) from vapor/gas phase. The two products blended together casts a wide net to remove a handful of inorganic and organic compounds. Features • (GAC) manufactured via high temperature steam activation from selected grades of coconut shell • VPP-CarbTM its high impregnated level of potassium permanganate and insignificant dusting attributes make it an ideal media • Potassium permanganate impregnated, 6 % wt. min. • Sold in bags, drums, and super sacs Applications • Air dryers • Scrubber tanks • Exhaust systems • Airports computer rooms • Trays, modules, air filtration housings • HVAC

Contaminants Removed • BTEX • Acid gases • Chlorinated solvent • Diesel fume • Asphalt fume • Butadiene • Smoke

Part Number VOC-Carb

Mesh 4x8

CCI4 60

Density 44.46 lb/ft3

Hardness 95%

UltraSorberTM CannaSorbTM The UltraSorberTM CannaSorbTM is a proprietary blend of selective media for odor and volatile organic compounds (VOC) removal. This media is successful at removing terpenoids and terpenes from vapor phase. Terpenoids and terpenes are large organic compounds produced by cannabis plants. The UltraSorberTM CannaSorbTM is commonly found in the final product handling rooms such as the curing/drying, cutting/deflowering, extraction, and packaging rooms. At the final product handling rooms the odors described as floral, fruity, pungent, or even skunky are strongest. Features • Does not promote bacterial or mold growth • Designed specifically for cannabis grow houses, but can be used in indoor cultivation facilities. • Sold one cubic foot boxes (33 lbs/box), drums, or supersacks

Part Number CannaSorb

74

Mesh 4x8

CCI4 60

Density 32-34 lb/ft3

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Hardness 95%

Applications

Contaminants Removed

• Curing/drying rooms • Cutting/deflowering rooms • Extraction and packaging rooms

• Terpenoids • Terpenes • Limonene • Pinene • Fertilizer VOC


Reversible Activated Carbon Filter Differential static pressure across filters will cause differential contaminent accumulation in the media. UltraventTM reversible carbon filter is the only filter to offer a solution with the twist lock flange and end cap allowing to reverse the filter and equalize contaminent distribution in the media. Most cylindrical-type air filters utilize 65% of the carbon available by only filtering through the top section of the carbon filter, leaving the bottom section unused. UltraventTM’s innovative patented design allows reversal of the filter, benefitting of 100% of the carbon available and extending the units' life span. Manufactured with only the finest high porosity activated carbon, UltraventTM effectively removes 99.5% of odors. Rated for a continuous worry-free operation and available in many different sizes and CFM ratings, UltraventTM filter can be used for industrial, commercial or residential applications.

Features • Rubber gasket to ensure air tight fitting • Twist lock Flange. No tools required • Parts made of high impact resistant polycarbonate • High quality galvanized steel • High capacity prefilter: - 20mm thickness - Low air resistance - Antibacterial - High capacity: 670g /m2 - Flame retardant • High porosity virgin extruded activated carbon 4mm. Specially designed to remove VOC. 66mm bed thickness • Convenient elastic band easing installation of the prefilter • Twist lock end cap. No tools required

Part Number

Recommended

Flange

Outside Height Diameter

Weight

Carbon Bed Width

Recommended Fan

Pressure Drop at Max CFM

UltraventTM 450 UltraventTM 650 UltraventTM 900 UltraventTM 1150 UltraventTM 1300

ER-450@0.1 sec ER-650@0.1 sec ER-900@0.1 sec ER-1150@0.1 sec ER-1300@0.1 sec

6" 6" 6" or 8" 8" or 10" 10" or 12"

15.4" 15.4" 15.4" 15.4" 15.4"

52.4 lbs 730 lbs 100.0 lbs 124.6 lbs 152.2 lb

2.6" (66 mm) 2.6" (66 mm) 2.6" (66 mm) 2.6" (66 mm) 2.6" (66 mm)

V600 & S600 V600 -V800 & S600 & S800 V600 - V1000 & S600 - S1000 V600 & S600 V1000 - V1200 & S1000

180 pa/.75wg 180 pa/.75wg 180 pa/.75wg 180 pa/.75wg 180 pa/.75wg

20" (50 cm) 30" (75 cm) 40" (100 cm) 50" (125 cm) 60" (150 cm)

AIR FILTRATION/TREATMENT

UltraVentTM Air Filter

UltraSorber-Air™-500 Features

Contaminants Removed

• Maximum Flow: 500 cfm • Carbon Weight: 2000 lbs • System Pressure Drop: 19" wc • Dimensions: 88" H x 46" W • Capacity: 500 Gallons • Weight: 650 lbs (Tank) + Media

• VOC • Hydrogen sulfide • Sulfur dioxide • Formaldehyde • Ethylene • Mercaptans

• Various aldehydes • Alcohols • Carbon dioxide • Nitrogen • Mercury • Solvents

Applications

Available To Rent

Part Number UltraSorber-Air™-500

Max Flow 500 cfm

• Emissions from industrial plants • Refinery and chemical plant wastewater • Soil vapor extraction • BioVenting • Emissions from waste processing operations • Air stripper off-gas VOC removal • API separator vents • Waste water and product storage tank vents • Emergency air quality control • ACI systems for mercury reduction • Lift stations • Industrial odor • Air treatment

Carbon Weight 2000 lbs

System Pressure Drop 19" wc

Dimensions 88" H x 46" W

Capacity 500 Gallons

Weight 650 lbs (Tank) + Media

AIR FILTR ATION/ TRE ATMENT

75


AIR FILTRATION/TREATMENT

UltraVentTM-OD Available To Rent

VOC & Odour Control Ventilator System

UltraVent™ is an effective and easily transportable air purification system for quick response specifically designed to treat toxic vapors, irritant and corrosive gases and other noxious odors in emergency, temporary or fixed situations which uses granular activated carbon to remove organic contaminants from an air stream. UltraVent™ system is easily portable and can be delivered and installed in hours at your facility or site. Includes • Metal drum with carbon • Top mounted blower • Start Switch with Internal thermal overload protection • 15 Feet of SOW cable and standard plug • Dolly with casters for ease of transportation Part Number

Max Flow

Motor

Dimensions

CARB-1071001-45G170 200 cfm @ 5" SP 1/2 hp, 34" W x 23" H 115V/1/60 CARB-1071001-85G310 375 cfm 1 hp, 40" W x 28" H 115V/1/60

Approx. Weight

Bottom Inlet Top Outlet

275 lbs

2" FNPT

4" O.D. Slip

400 lbs

4" FNPT

5" O.D. Slip

*Tubing not included

UltraSorberTM-Air Treatment Units

What is your contaminant? ERE manufactures the UltraSorberTM Air treatment units for many different types of applications. From industrial to commercial applications. Also available in different sizes. Each unit is specifically designed for each application. Drum Size 5 gal. (Plastic) 10 gal. (Plastic) 25 gal. (Plastic) 55 gal. (Metal or Plastic) 85 gal. (Metal) 250 gal. (Plastic)

76

Liquid Loading Rate 36.7 cfm @ 20 cfm 36.59 cfm @ 45 cfm 42.08 cfm @ 85 cfm 54.35 cfm @ 150 cfm 82.87 cfm @ 300 cfm 60 cfm @ 600 cfm

1- 8 8 8 -287- 3732 | EREINC.C OM | SALES@EREINC.C OM

Time Residence 1.9 Sec @ 20 cfm 1.64 Sec @ 45 cfm 3.09 Sec @ 85 cfm 3.21 Sec. @ 150 cfm 2.08 Sec. @ 300 cfm 2.67 sec @ 600 cfm

Inlet & Outlet 1" FNPT 1 1/4" FNPT 2" FNPT 2" FNPT 4" FNPT 4" Slip / 6" Slip


Drum Material

Bulk Density

Mesh Size

Approx. Media Weight

Flow Rate

Max Pressure

35 lbs/cf

6x8

210 lbs 315 lbs

150 cfm 375 cfm

8 psi 3 psi

Metal

36 lbs/cf

4x6

216 lbs

150 cfm

8 psi

324 lbs

375 cfm

3 psi

Metal

45 lbs/cf

4 x 16

270 lbs

150 cfm

8 psi

405 lbs

375 cfm

3 psi

180 lbs

50 cfm

8 psi

270 lbs

375 cfm

3 psi

180 lbs

150 cfm

8 psi

270 lbs

375 cfm

3 psi

11.2 lbs

25 cfm

1 psi

28 lbs

40 cfm

1 psi

UltraSorber-AmmoTM, Ammonia Removal Media: Anthracite Coal impreg. Phosphoric Acid 90-015-55M 55 gal Metal 90-015-85M 85 gal TM UltraSorber-CHLORO , Chlorine & Acidic Gas Removal Media: Anthracite Coal impreg. Potassium Hydroxide 90-016-55M

55 gal

90-016-85M

85 gal

UltraSorber-MistTM, Oil Mist Removal Media: Bituminous Coal Based Carbon 90-017-55M

55 gal

90-017-85M

85 gal

UltraSorber-BC , General Contaminants of low and High Mol Weight Removal TM

Media: Bituminous Coal Based Carbo 90-018-55M

55 gal

90-018-85M

85 gal

Metal

30 lbs/cf

4 x 10

UltraSorber-CSTM, Trace Contaminants Lower than 80 Mol Weight Removal Media: Carbon Coconut Shell 90-019-55M

55 gal

90-019-85M

85 gal

Metal

30 lbs/cf

4x8

AIR FILTRATION/TREATMENT

Drum Size

Part Number

UltraSorber-ODORTM, Sewage Odour Control - H2S or Sulphur Compounds Removal Media: Catalytic Activated Bituminous Coal Based Carbon 90-020-5P

5 gal

90-020-10P

10 gal

90-020-25P

25 gal

84 lbs

85 cfm

1 psi

90-020-55P

55 gal

168 lbs

150 cfm

2 psi

90-020-250P

250 gal

880 lbs

600 cfm

1 psi

216 lbs

150 cfm

8 psi

324 lbs

375 cfm

3 psi

204 lbs

150 cfm

8 psi

306 lbs

375 cfm

3 psi

Plastic

28 lbs/cf

4x6

UltraSorber-FUMETM, Used with Fume Hoods Media: Anthracite Coal Impreg. Potassium Hydroxide and Potassium Iodine 90-021-55M

55 gal

90-021-85M

85 gal

Metal

36 lbs/cf

4x6

34 lbs/cf

4 x 10

UltraSorber-MERCTM, Mercury Removal Media: Bituminous Coal Based Carbon Impreg. Sulphur 90-022-55M

55 gal

90-022-85M

85 gal

Metal

UltraSorber-FORMATM, Removes Alcohols, Aldehydes, Amines, Ethylene, Formaldehyde, Mercaptans, Organicacids, Oxides, Sulfur compounds (H2S, SO2, etc.), vinyl chloride, etc Media: Zeolite Impreg. with Potassium Permanganate 90-023-55M

55 gal

90-023-85M

85 gal

Metal

55 lbs/cf

4x8

330 lbs

150 cfm

8 psi

495

375 cfm

3 psi

UltraSorber-ALCOTM, Removes Alcohols, Aldehydes, Amines, Ethylene, Formaldehyde, Mercaptans, Organic acids, Oxides, Sulfur compounds (H2S, SO2, SOx etc.), vinyl chloride, etc. Media: Zeolite Impreg. with Potassium Permanganate Mixed with Coconut Shell 90-024-55M

55 gal

90-024-85M

85 gal

Inf Z

ne

Metal

45 lbs/cf

4x8

270 lbs

150 cfm

8 psi

405 lbs

375 cfm

3 psi

When considering activated carbon for air filtration, several factors needs to be taken into account: • Adsorbate type and concentration • Oxidation/reaction potential for adsorbed compounds (most commonly associated with ketones) • Air temperature • Relative humidity of the air stream (RH levels in excess of 50% can lead to excessive moisture adsorption onto the carbon, impacting contaminant removal)

AIR FILTR ATION/ TRE ATMENT

77


REPAIR AND CALIBRATION SERVICES

ERE is the Ultimate source in Environmental Equipment. This reputation also demands ultimate service for the equipment. You can rely on ERE’s service department for timely repair and/or calibration of instruments and equipment. Whether it’s a routine calibration, maintenance or repair, come and join us! The coffee is on us!


You can order by phone, fax, email, and internet. Our customer service staff will be happy to assist you.

Tel: 514-326-8852 1-888-287-EREC (3732) Email: sales@ereinc.com Web: www.ereinc.com

Register online today and receive our monthly promotions and product updates. Discounts available for bulk orders or yearly contracts.

Our products are subject to change

ier

OUR STORE

am arc he Ru eL

Ru eB

om ba r

Parc Lucie-Bruneau

Ru eC

ham

pd

’Ea u

8605 Champ d’Eau Montréal, Quebec, Canada H1P 3B8 Tel: 514-326-8852 • Fax: 514-326-8961 Monday–Friday 8:00 AM to 4:30 PM


AIR

V O L . 5

SAMPLING MONITORING F I LT R AT I O N T R E AT M E N T