GENERAC 7.5L Diesel Service Manual Reference Mitsubishi 6D16-T 6D162PT 6D162PT041

Page 342

R <24V-35A>

A

• Removal sequence

<Type A>

1 2 3 4 5

Adjust bolt Adjust shaft <Type B> V beit Alternator assembly CD P.54-48 Adjust plate

* : Alternator bracket WARNING&-------

Before removing the alternator 4, be sure to disconnect the negative 0 terminal of the battery and insulate it with a tape or something else. If the negative termi­ nal is not disconnected, the battery volt­ age is always available at terminal B and is dangerous.

e

®16745

<Type B>

A 1 ......... ;11"11,11 ........ :-- ---· ·----­ - 11 h;;HQIIQUVI I ,:n;;\.tUCI l\,C

Reverse the order of removal. • Adjustment after installation Adjust the tension of the V-belt 3. CD Gr 14

1

3

®46895

Service standards Location 4

Maintenance item Alternator output current (* When hot, when 27V is generated)

Alternator speed

Regulator regulated voltage (5000 rpm, loads SA or less)

Standard value 1500 rpm

20A or more

2500 rpm

29A or more

5000 rpm

33A or more 28.5 ± 0.5V

Limit

-

-

Remedy Check

Replace

*: "When hot" refers to the state of the engine after 30 minutes of maximum output operation at 5000 rpm at a normal ambient temperature.