Page 1

Design Specifications DS-1200 March, 2003

Series 1200 Liquid Turbine Meter High Performance Turbine Technology with Dual Output Capabilities in a Single Housing DESCRIPTION: The Daniel Series 1200 Turbine Flowmeter is a volumetric flow metering and transmitting device used extensively in the petroleum industry for the accurate measurement of liquid hydrocarbons. The meter's simple configuration assures higher flow rates, extended flow range and sustained performance capability. This meter is specifically designed for loading rack service where a vital characteristic is repeatability. The primary reason for this superior performance with light hydrocarbons is the Series 1200's lightweight rotor with free spinning, self-cleaning design having flow through ball bearings. For more harsh applications where rough or other matter may be present, upgrade to the stainless steel ball bearing option. For the most severe applications, upgrade to the tungsten carbide bearing option. Flow range does not have to be reduced for fluids with specific gravities as low as 0.5, and the meter maintains linearity on fluids with viscosities up to 4 centistokes. This versatile meter operates in both the horizontal and vertical upflow installations. It features patented expanding hangers to center internals in the body. The standard design includes a flow conditioning plate, which allows a customer to operate without the conventional upstream tube bundled flow straightener. When such a configuration is elected, spool length and flexible hose lengths may be shortened accordingly, especially valuable with vertical loading racks. Daniel Measurement & Control recommends that API recommendations be followed. This meter is designed for use within the guidelines of API Standards, Chapter 5.3, formerly Standard 2534 (The Measurement of Liquid Hydrocarbons by Turbine Meter Systems) and the test procedures of API Standards, Chapter 4 (Prover Systems). DESIGN FEATURES • Output linear with flowrate • Rangeability of 10 to 1 • Horizontal or vertical installation • Superior accuracy and repeatability • High frequency pulse resolution • Uniform pulse signal output • Improved serviceability allows easy access to pickoffs and reduces installation costs • Simple, easy to maintain, field mountable pickoffs require no interruption of conduit lines • Explosion proof/weather proof housing • Integral & remote electronic register (optional)

!

WARNING

Do not operate this instrument in excess of the specifications listed. Failure to heed this warning could result in serious injury and/or damage to the equipment.

Design K-Factor K-Factor Pulses Size 3” 4”

GAL

2184

M3 13,738

966

6,077

23

BBL

52

Note: See Model Code for meter options configurations and accessories

MATERIALS OF CONSTRUCTION Meter Body: Carbon Steel (Standard), 304 SS optional Internal Components: Aluminum, (Standard) Thermoplastic Flow Conditioning Plate is part of the internal assembly Bearings: Turcite, (Standard) Stainless Steel, or Tungsten Carbide UMB Housing: Aluminum RATINGS Pressure: ANSI pressure/temperature rating corresponding to flanges used. Temperature: -20 to 180°F (-29 to 82°C) PICK-OFF SPECIFICATIONS Type: Reluctance Resistance: 1000 ohms ±15% Inductance: 250 mH max. Output: 40mV p-p min. @ min. flow with pre-amp load PERFORMANCE - METER Linearity: ± 0.15% Repeatability: ± 0.02%

Page 1 of 2


Shipping Weight and Volume 150 lb. ANSI

Design Specifications DS-1200 March, 2003

300 lb. ANSI

SIZE 3”

Lbs.

Kg.

Cu. Ft.

Cu. Mtr.

Lbs.

Kg.

Cu. Ft.

Cu. Mtr.

60

27.2

1.13

0.032

65

29.5

1.25

0.035

4”

75

34.0

1.53

0.043

80

36.3

1.78

0.05

Flow Range Products having a specific gravity of 0.5 to 1.0 and a viscosity of 0.3 to 4.0 cst.

SIZE

Standard Flow Range BBL/Hr

Extended Flow Range BBl/Hr

Standard Flow Range M3/Hr

Extended Flow Range M3/Hr

Standard Flow Range GPM

Extended Flow Range GPM

3”

93-930

1071

14.8-148

170

65-650

4”

143-1430

1785

23-230

284

100-1000

CONNECTIONS Mechanical: Standard - 150, 300 lb. ANSI R.F. flanges Electrical: Class I, Division 1, Groups C & D, CUL, and NEMA 4X, UL, CENELEC EEx d IIB T6 Transmission Distance: Without Pre-amp: 20 ft. (6.1 meters) With Pre-amp: 3,000 ft. (914 meters) Belden 88442 or equivalent up to 20 ft. Pressure Drop: 3 psi (20.7 kPa) at maximum flow rate (based on gasoline - meter only).

A SIZE 3” 4”

Inch 10 12

B mm 254 305

Inch 3 7/8 4 1/2

Inch 7 3/4 8 1/4

kPa

750

3

21

1250

3

21

Model

ANSI Connection

Maximum Working Pressure @ 100°°F (Carbon Steel)

T03

3”, 150 lb. ANSI

285 psi

275 psi

T03

3”, 300 lb. ANSI

740 psi

720 psi

T04

4”, 150 lb. ANSI

285 psi

275 psi

T04

4”, 300 lb. ANSI

740 psi

720 psi

D mm 197 209

psi

PERFORMANCE - Pre-amplifier Inputs: Supply voltage: 20 Vdc ± 50% Signal Type: Sine Wave Signal Amplitude: 40 mV p-p minimum Outputs: Powered Pulse Output Type: Square Wave Frequency Range: 0 to 5 kHz@ Amplitude: 0 to 5V Loading: 1 kOhm internal pull-up Variable Voltage Output Type: Square Wave Frequency Range: 0 to 5 kHz @ Amplitude: 0 to Supply Voltage Loading: 1 kOhm internal pull-up Open Collector Output Type: Square Wave Frequency Range: 0 to 5 kHz Max. Voltage: 30 Vdc Max. Current: 125 mA Max. Power: 0.5 Watts Flange Connections

C mm 98 114

Pressure Loss

Inch 15 20

E mm 381 508

Inch 15 20

Maximum Working Pressure @ 100°°F (304 SS))

F mm 381 508

Inch 40 52

G mm 1015 1320

Inch 6 1/2 7

mm 165 178

Daniel Division Headquarters Houston, Texas, USA, T: (713) 467-6000, F: (713) 827-3880 Calgary, Alberta, Canada, T: (403) 279-1879, F: (403) 236-1337 Stirling, Scotland - Europe, Mid-East & Africa,T: +44 1786 433400, F: +44 1786 433401 Singapore - Asia Pacific, T: +65-6777-8211, F: +65-6770-8001 USA Toll Free 1-8 888-FFLOW-0 001 www.daniel.com Daniel is a wholly owned subsidiary of Emerson Electric Co., and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industries, Inc. The Emerson logo is a registered trademark and service mark of Emerson Electric Co.

2003 Daniel Measurement and Control, Inc., all rights reserved.

Printed in USA ,

DAN-DS1200-3M-03/03

PDS_1200_DS_1200_2003-03_EN  

Design Specifications DS-1200 March, 2003 Page1of2 DesignK-Factor Do not operate this instrument in excess of the specifications listed. Fai...