Issuu on Google+

www.oraclelighting.com

The Elite Source of Controllable Architectural Lighting


3 3 3

Green Lighting. Green Design. Energy Conservation. That is our commitment to you!

www.oraclelighting.com


We have achieved green lighting design by committing to all energy conservation & government economy programs ...

Oracle Lighting is committed to designing building and producing the most diverse line of linear fluorescent products that will fulfill all the needs of specifiers, architects and engineers. We are dedicated to developing energy efficient products that help meet strict energy codes and help preserve the planet. All of Oracle Lighting products from recessed Direct/ Indirect fixtures to Fluorescent High Bays are engineered with the utmost craftsmanship and attention to detail. They not only provide aesthetically pleasing designs, but also enhance the visual environment. Through continuous research and development, Oracle Lighting has become a leader in lighting solutions for every sector of the industry and strive to become the most respected lighting company in the industry. As part of our commitment to meeting all the requirements presented to us by our growing list of customers, Elite Lighting has achieved full compliance with the Buy American Act (1933) and the American Recovery and Reinvestment Act (2009). These Acts contain “Buy American Provisions” that have certain restrictions regarding where goods or supplies for public use are purchased with public funding.

AARA Solutions

Our compliance ensures that we can fulfill any and all lighting requests and projects.

4

WWW.ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


Saving Energy & the Environment Preserving and improving our environment is our common goal. Using energy efficient, low mercury fluorescent lamps, are another answer to being

green.

THE FLUORESCENT ADVANTAGE For general illumination applications fluorescent lamps and fixtures, compared to incandescent and HID lamps, have proven to offer several advantages. These advantages include lower energy consumption, longer lamp life, superior maintained lamp lumens per watt and reduced maintenance cost. Although fluorescent lighting has been available since the mid 1940’s, continued product improvements in the lamp and the current use of electronic ballast technology has insured that fluorescent lighting is still an effective and efficient lighting tool. The current linear T8 and T5 lamps and corresponding electronic ballasts are vastly more efficient than any type of incandescent lamp in general commercial lighting applications. The recent use of T5HO fluorescent lamps is rapidly replacing HID lighting products in warehouse, manufacturing, retail and other high ceiling spaces. Linear fluorescent lighting provides a uniform level of light in the workspace for various types of tasks. These fixtures can be dimmed or equipped with motion sensors or timers to meet the prevailing energy conservation codes and requirements. Most local electrical utilities now offer rebate programs to encourage existing property owners to covert incandescent and HID fixtures and lamps to linear T8, T5 and T5HO lighting. Compact fluorescent has also made tremendous progress in replacing incandescent lamps as small point sources in recessed downlights, wall mounted and/or surface mounted fixtures. Additionally, the latest “induction fluorescent” lamp is another lighting tool that is being used to challenge HID lighting products. This product ignites in nearly full mode and can subsequently be used with motion sensors. Led supporters are attempting to challenge the fluorescent dominance in the commercial lighting industry. However, given the current LED technology that is available today there is no comparison to the fluorescent lamp as to lumen output per watt and cost of the system. Led products have made tremendous headway in many applications and appears to offer some future opportunities in the lighting sector. Elite Lighting has fully embraced the concept and advantages of fluorescent lighting. We offer an extensive line of fluorescent light fixtures that cover a large cross-section of lighting applications. We provide numerous lamp options as to wattage, color temperature and lamp size (length) coupled with the latest electronic controls that the industry has to offer.

6

WWW.ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


EFFICIENT ... QUALITY ... HIGH PERFORMANCE ... All Oracle products are designed and engineered to be highly efficient and effective in delivering high quality lighting to the intended task. Saving or reducing energy is critical to our fragile environment today and for our future generations. Energy conservation also saves money and operational costs to encourage a productive and enjoyable workplace environment. Lighting is at the core of one of the primary human senses…SIGHT. Whether it is at work, school, play or just relaxing, people perform better and are more comfortable when the interior space is properly illuminated. Optional dimming controls also offer an additional means to alter lighting levels as required. The optical engine of these products utilizes highly reflective interior paint and acrylic lenses that are high transmission (95%) which delivers the maximum amount of light possible. Retail, hospitality and entertainment industries utilize lighting to attract attention and to create excitement... with the intention of drawing customers to their facilities for increased business and profits.

S H I P P I N G AVA I L A B L E

All Oracle products are available with a factory installed and tested lamp option to speed installation and job completion. Oracle is pleased to offer a complete line of energy efficient lighting products that meet or exceed the current energy conservation codes and subsequent utility rebate programs. A large selection of Oracle products are available with our same day shipping service. Contact our factory for more information on these products. As part of our commitment to meeting all the requirements presented to us by our growing list of customers, Elite Lighting has achieved full compliance with the Buy American Act (1933) and the American Recovery and Reinvestment Act (2009). These acts contain “Buy American Provisions” that have certain restrictions regarding where goods or supplies for public use or purchased with public funding can be made. Our compliance ensures that we can fulfill any and all lighting assignments. 7


Ta b l e o f C o n t e n t s Oracle LED Volumetric Downlight

Oracle Fluorescent Recessed Troffer OT, OFT, OSMT

Oracle Fluorescent Linear ASI1, ASI2, ASI3, ASW1, ASW2, OB1DI, OB2DI, OB3DI, OB4DI, OB5DI

Dawn

10

page Oracle Fluorescent Recessed Volumetric ODVH, OD1V, OD2V, OD3V, OD4V,

58

Dawn

page Oracle Fluorescent High Bay CB, ORCB, GHB, SB, SDB, DHB

12

page

Oracle Fluorescent Recessed Direct/Indirect OD, ODS, OBLD, OSDI, OCDI, ONDI, OEDI

68

page Oracle Fluorescent Wet Location High Bay HD1B, HD2B, OWVS, OW1IP, PW2IP, OW3IP

152

page

Twilite Oracle Fluorescent Surface Mount OEW, OIW, OSC, ONW

94

page

26

page

Oracle Fluorescent Cove Lighting System OSRT5, OST5, OSTG, OCN, OC, OCS, OIC, OCNR, OCT, OICT,

Oracle Fluorescent Recessed Parabolic OHP, OP, OSMP, OPDVT

172

page

Oracle Fluorescent Wall Bracket/ STAIRWELL OW1B, OW2B, OW3B, OSL

38

page

8

116

page

178

page


Ta b l e o f C o n t e n t s Oracle Fluorescent Vanity OVLM, OVL

Oracle Retrofit/ Strip Kit ORTK, ORPK, OIRK, ORSK

182

210

page

Oracle Fluorescent Vandal OV1R, OV2R, OVLM, OVL, OV3R, OV4R, OV5R

Full Cut-Off Wall Pack OWP-FC-201, OWP-FC-301, OWP-FC-401

page Oracle Flange Kit 14FK, 22FK, 24FK

Semi Cut-Off Wall Pack OWP-SC-201, OWP-SC-301, OWP-SC-401

214

page

184

page

236

page

Dimming Ballast, Emergency Chart LUTRON, PHILIPS

Oracle Fluorescent Surface Mount OMS, ORS, OSS

240

page

No Cut-Off Wall Pack OWP-NC-101, OWP-NC-102, OWP-NC-201, OWPNC-301, OWP-NC-401OWP-SQ-301, OWP-SL-101, OWP-SL-102

216

page

244

page

189

page

Leviton Motion Sensor WIRELESS CONTROLS, WALL SWITCHES

Oracle Fluorescent Under Cabinet EUM, EUT, EZU, EUS, EU

Flood Light/ Area Light OFL-101, OFL-SP-101, OFL-301,OFL-AR-301, OFLAR-401

220

page

193

254

page

page

Oracle Vandal Resistant ORG201, ORG202, ORG302, OVR201, OVR301

Wall Sconce OWS-FC-202, OWS-FC-203, OWS-FC-303

199

230

page

page

Bollard Lighting OBO-101, OBO-102, OBO-103, OBO-104

263

page

Oracle High/ Low Bay OLB, OIH, OZB, OHB, OCF, OHB Cylinder Wall Sconce OWS-CYL-UD-101, OWS-CYL-101

204

page

Step Light ST301, ST302, ST106, ST107, ST108, ST109, ST104, ST105, ST401, ST402, ST403, ST701, ST702, ST703, ST801, ST802

232

page

269

page

9


2x2 led VOLUMETRIC downlight NE

W

OV-LED SERIES

dimension 3-1/8"

23-3/4"

OV

LED Direct/ Indirect Recessed

Fluorescent Recessed Volumetric

2X2

Spacing Criteria: 1.4 • Lumens: 3082 • Life Span: 50,000 hours

The new Elite LED Architectural OV-LED fixture adopts the latest technology in optic technology for use in many commercial applications. As a result of extensive research and development, it provides a very pleasant soft light that is comfortable to the eye and provides great illumination. With a CRI in the mid 80’s and a great thermal management design, the OV-LED lay in will be the perfect fit for any application. OPTICS - By using two frosted extruded acrylic lens, the OV-LED gathers the light scattered by the LED chips and shapes it into functional beams that will provide even illumination throughout any given environment. Our frosted acrylic lens will not only redirect high angle rays to reduce glare but will also direct low angle rays into usable light. The lens can be easily removed in case maintenance is required. DURABILITY - Heavy duty 20 gauge aluminum housing is engineered for maximum strength. Corners interlock to prevent aesthetically damage to fixture. All sides and corners are tuned in and hemmed to remove sharp edges for safe handling and installation. LED light engines are attached directly to the aluminum housing and keeps LED engines cool. Our advanced thermal management system allows the light output of the LED engines to be maintained at 70% of initial lumens at 50,000 hrs of operation.

PERFORMANCE - The OV-LED architectural lay in fixture consumes 46 watts of power and puts out more than 3000 lumens. It meets higher efficacy codes and compliances with more than 60LPW. The light engines found in the OV-LED are rated at 85CRI at a 3500K color temperature as rated and tested to LM-79 and LM-80 standards. LED driver is rated for 50 to 60Hz at 120-277V input, produces less than 10% THD, and has a power factor of .90 to 1.00. It also comes with NEC required ballast disconnect as a standard. DIMMING - The 22-OV -LED comes standard with 0-10V Dimming on either 120 or 277V. Consult factory for specific dimmers. MAINTENANCE - LED engines can be accessed through the bottom by removing the lamp shields. Ballast can be accessed though top via hinged doors.

PENDING

Ordering information: Example: 22-OV-LED-46-35k-120

10

22

oV

led

fixture size 2X2

series OV - Oracle Direct/Indirect

type LED

46

35K

120

wattage 46

CCT 35K-3500k 41K-4100K 50K - 5000k

voltage MVOLT 120V 277V

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

emergency option EMG

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


Dawn Series The new Elite LED Architectural OV-LED fixture adopts the latest technology in optic technology for use in many commercial applications

2X2 OV

LED Direct/ Indirect Recessed

photometrics TRIM: 22-OV-LED-46-35k-120

lumens: 3082

278

555

833

1111

Zonal Lumens Summary Zone 0-30 0-40 0-60 0-90

Lumens 861.89 1414.7 2500.17 3082.29

%Lamp N.A. N.A. N.A. N.A.

WWW. ORACLELIGHTING . COM

%Fixt 28 45.9 81.1 100

spacing criteria: 1.4

Candela Tabulation 0.0 0 . . . . . 1110.57 5 . . . . . 1096.43 10 . . . . 1083.66 15 . . . . 1060.18 20 . . . . 1023.34 25 . . . . 974.14 30 . . . . 912.33 35 . . . . 840.57 40 . . . . 758.93 45 . . . . 667.00 50 . . . . 567.07 55 . . . . 464.28 60 . . . . 363.45 65 . . . . 270.82 70 . . . . 186.36 75 . . . . 117.54 80 . . . . 65.44 85 . . . . 28.40 90 . . . . 6.38

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22.5 1110.57 1101.02 1086.69 1062.71 1026.63 980.52 924.53 857.11 778.48 694.21 605.38 509.97 415.10 324.61 240.32 164.65 93.59 34.27 5.87

45.0 1110.57 1096.61 1082.43 1064.77 1033.97 994.20 946.90 887.63 822.23 750.10 671.12 589.28 501.47 411.96 308.98 187.13 90.05 33.11 4.80

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

67.5 1110.57 1102.23 1083.99 1066.35 1037.41 1003.14 961.62 912.68 855.13 792.06 719.54 639.23 553.28 438.05 270.89 142.14 72.53 28.98 4.29

90.0 1110.57 1097.83 1084.99 1066.72 1041.44 1003.21 962.23 918.94 862.77 799.21 730.07 654.16 565.09 418.55 238.18 124.41 69.87 26.68 3.54

11


Dawn

UP TO

86%

EFFICIENCY

More Green, Greater illumination, Higher efficiency, Less Energy

12


D

Dawn of a new era of highly efficient recessed architectural volumetric lighting. Dawn is a new series of highly efficient volumetric recessed lighting to be utilized in a variety of environments to create a comfortable open space while meeting the requirements of the most aggressive energy codes.

Volumetric lighting A term commonly used in the lighting industry to identify luminaires that are less directional and provide more uniformity throughout the entire volume of a space. Volumetric lighting not only enhances the work plane, but also illuminates both horizontal and vertical surfaces to eliminate the “cave� effect that most directional luminaires create. Illumination is balanced throughout the visual environment and creates a feeling of larger, brighter work spaces. Volumetric lighting is the ultimate solution to render architectural spaces in its true form.

13


DAWN

T8/T5, 2’ X 4’ FLUORESCENT RECESSED VOLUMETRIC (HIGH EFFICIENCY LUMINAIRE)

ODVH

S H I P P I N G AVA I L A B L E

APPLICATION: Intended for spaces requiring volumetric lighting to enhance brightness and size appearance. Highly efficient general illumination for school classrooms/ multipurpose rooms, office spaces, office complexes and retail stores. PRODUCT FEATURES: • Up to 80% efficiency. • Proprietary “wide beam high transmission” frosted lens design, delivers uniform illumination that creates a balance in the entire volume of a space, compared to perforated metal baskets with white overlays. • Enclosed linear prismatic lens fully encapsulates lamp and ballast compartment and protects against any foreign objects entering electrical compartment, thus eliminating the need for dust cover. • Highly efficient and translucent Acrylic frosted lens. • Reflected light from engineered white sloping interior fixture reflectors provide a secondary wide beam distribution angle to deliver exceptionally high total fixture efficiency performance. • Performance maximized for highest efficiency while preventing lamp image. • Soft white paint maximizes distribution and provides visual comfort. • Supplied standard with Philips Advance or Universal ballast. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Includes built-in earthquake tabs. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

5-11/16" 23-11/16"

47-13/16"

2X4 ODVH

Ordering Information Example: 24-ODVH-3-32-T8 24

ODVH

Fixture Size

trim type

Fluorescent Recessed Volumetric

24 - 2’ X 4’

voltage2

(Consult factory for Slot T mounting option)

# lamps/lamp type

series ODVH-Oracle Volumetric High Efficiency Series

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8) 3-32-t8 (3 lamps/32W/T8)

1-28-t5 2-28-t5 3-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (3 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank)1 -

(Blank) ADV-71 ADV-101

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

ADV-ROVR

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-2W1

-

-

Lutron Tu-Wire2

LUT-EC5 LUT-EC51

-

Lutron Ecosystem2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3 LUT-EC31

LUT-EC31

LUT-TVE1

1

-

LUT-H3D LUT-H3D -

-

1

1

2

OTHER options

Lutron Eco-102 Lutron Tve2

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD1

Lutron Ecosystem (347V Only)2

2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

14

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-ODVH-2-32-T8-MAS2 and 24-ODVH-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

SBF - Internal Slow-Blow Fuse

C4 - 6’ 4-wire Flex Cable (Double Circuit) USA - Made in America Compliance

FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

RIS - Radio Interference Suppressor

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


15


16


T8/T5, 2’ X 2’ FLUORESCENT RECESSED VOLUMETRIC (HIGH EFFICIENCY LUMINAIRE)

D A WN

ODVH

S H I P P I N G AVA I L A B L E

APPLICATION: Intended for spaces requiring volumetric lighting to enhance brightness and size appearance. Highly efficient general illumination for school classrooms/ multipurpose rooms, office spaces, office complexes and retail stores. PRODUCT FEATURES: • Up to 80% efficiency. • Proprietary “wide beam high transmission” frosted lens design, delivers uniform illumination that creates a balance in the entire volume of a space, compared to perforated metal baskets with white overlays. • Enclosed linear prismatic lens fully encapsulates lamp and ballast compartment and protects against any foreign objects entering electrical compartment, thus eliminating the need for dust cover. • Highly efficient and translucent Acrylic frosted lens. • Reflected light from engineered white sloping interior fixture reflectors provide a secondary wide beam distribution angle to deliver exceptionally high total fixture efficiency performance. • Performance maximized for highest efficiency while preventing lamp image. • Soft white paint maximizes distribution and provides visual comfort. • Supplied standard with Philips Advance or Universal ballast. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Includes built-in earthquake tabs. • NEC required ballast disconnect is standard.

5-11/16" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-3/4"

2X2

Ordering Information Example: 22-ODVH-3-17-t8 22

ODVH

oDVH

Fixture Size

trim type

voltage2

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series ODVH-Oracle Volumetric High Efficiency Series

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8) 3-17-t8 (3 lamps/17W/T8)

1-14-t5 2-14-t5 3-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (3 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-ODVH-2-17-T8-MAS2 and 22-ODVH-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR1

-

-

-

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire2

LUT-EC51 LUT-EC51

LUT-EC5

LUT-EC5

LUT-EC3 LUT-EC31

LUT-EC3

LUT-EC3

-

-

LUT-H3D

LUT-H3D

-

-

-

-

LUT-H3D LUT-H3D

1

-

-

2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem2

OTHER options

Lutron Eco-102 Lutron Tve2 Lutron Hi-Lume 3D

2

Lutron Ecosystem (347V Only)2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Fluorescent Recessed Volumetric

22 - 2’ X 2’

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

SBF - Internal Slow-Blow Fuse

C4 - 6’ 4-wire Flex Cable (Double Circuit) USA - Made in America Compliance

FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

RIS - Radio Interference Suppressor

17


DAWN

T8/T5, 2’ X 4’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT FLAT “HT” LENS)

OD1V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary flat High Transmission (HT) acrylic diffusing panel with low brightness glow. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

16" 22" 4" 23-11/16"

47-13/16"

2X4 OD1V

Ordering Information Example: 24-OD1V-2-32-T8 24

OD1V

Fixture Size

trim type

Fluorescent Recessed Volumetric

24 - 2’ X 4’

voltage1

(Consult factory for Slot T mounting option)

# lamps/lamp type

series OD1V-Oracle Dawn Direct/ Indirect

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8)

1-28-t5 2-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-2W

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

LUT-H3D LUT-H3D -

-

1

OTHER options

Lutron Eco-101 Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

18

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OD1V-2-32-T8-MAS2 and 24-OD1V-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT FLAT “HT” LENS)

D A WN

OD1V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary flat High Transmission (HT) acrylic diffusing panel with low brightness glow. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

16" 22" 4" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-11/16"

2X2

Ordering Information Example: 22-OD1V-2-17-T8 22

OD1V

OD1V

Fixture Size

trim type

voltage1

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series OD1V-Oracle Dawn Direct/ Indirect

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8)

1-14-t5 2-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OD1V-2-17-T8-MAS2 and 22-OD1V-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

-

-

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC3

LUT-EC3

LUT-EC3

LUT-EC3

-

-

-

-

LUT-H3D

LUT-H3D

-

-

LUT-H3D LUT-H3D -

-

1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem1

OTHER options

Lutron Eco-101 Lutron Tve1 Lutron Hi-Lume 3D

1

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Fluorescent Recessed Volumetric

22 - 2’ X 2’

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

19


DAWN

T8/T5, 2’ X 4’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT RADIAL “HT” LENS)

OD2V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary radial High Transmission (HT) acrylic diffusing panel with low brightness glow. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

16" 22" 4" 23-11/16"

47-13/16"

2X4 OD2V

Ordering Information Example: 24-OD2V-2-32-T8 24

OD2V trim type

Fixture Size

Fluorescent Recessed Volumetric

24 - 2’ X 4’

voltage1

(Consult factory for Slot T mounting option)

# lamps/lamp type

series OD2V-Oracle Dawn Direct/ Indirect

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8)

1-28-t5 2-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-2W

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

LUT-H3D LUT-H3D -

-

1

OTHER options

Lutron Eco-101

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

20

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OD2V-2-32-T8-MAS2 and 24-OD2V-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT RADIAL “HT” LENS)

D A WN

OD2V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary radial High Transmission (HT) acrylic diffusing panel with low brightness glow. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

16" 22" 4" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-11/16"

2X2

Ordering Information Example: 22-OD2V-2-17-T8 22

OD2V

OD2V trim type

Fixture Size

voltage1

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series OD2V-Oracle Dawn Direct/ Indirect

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8)

1-14-t5 2-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 1

14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OD2V-2-17-T8-MAS2 and 22-OD2V-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

-

-

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC3

LUT-EC3

LUT-EC3

LUT-EC3

-

-

-

-

LUT-H3D

LUT-H3D

-

-

LUT-H3D LUT-H3D -

-

1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem1

OTHER options

Lutron Eco-101 Lutron Tve1 Lutron Hi-Lume 3D

1

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Fluorescent Recessed Volumetric

22 - 2’ X 2’

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

21


DAWN

T8/T5, 2’ X 4’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT PERFORATED SHIELD WITH OVERLAY)

OD3V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary High Transmission (HT) acrylic diffusing side panel with low brightness glow. The perforated center basket with white overlay shield offers a soft downlight distribution. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

16" 22" 4" 23-11/16"

47-13/16"

2X4 OD3V

Ordering Information Example: 24-OD3V-2-32-T8 24

OD3V

Fixture Size

trim type

Fluorescent Recessed Volumetric

24 - 2’ X 4’

voltage1

(Consult factory for Slot T mounting option)

# lamps/lamp type

series OD3V-Oracle Dawn Direct/ Indirect

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8)

1-28-t5 2-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-2W

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

LUT-H3D LUT-H3D -

-

1

OTHER options

Lutron Eco-101

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

22

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OD3V-2-32-T8-MAS2 and 24-OD3V-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT PERFORATED SHIELD WITH OVERLAY)

D A WN

OD3V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary High Transmission (HT) acrylic diffusing side panel with low brightness glow. The perforated center basket with white overlay shield offers a soft downlight distribution. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

16" 22" 4" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-11/16"

2X2

Ordering Information Example: 22-OD3V-2-17-T8 22

OD3V

OD3V

Fixture Size

trim type

voltage1

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series OD3V-Oracle Dawn Direct/ Indirect

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8)

1-14-t5 2-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OD3V-2-17-T8-MAS2 and 22-OD3V-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

-

-

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC3

LUT-EC3

LUT-EC3

LUT-EC3

-

-

-

-

LUT-H3D

LUT-H3D

-

-

LUT-H3D LUT-H3D -

-

1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem1

OTHER options

Lutron Eco-101 Lutron Tve1 Lutron Hi-Lume 3D

1

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Fluorescent Recessed Volumetric

22 - 2’ X 2’

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

23


D AWN

T8/T5, 2’ X 4’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT WITH LOUVER)

OD4V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary flat High Transmission (HT) acrylic side diffusing panel with low brightness glow. Center blade louvers control light and distribute light to task. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp bshields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

16" 22" 4" 23-11/16"

47-13/16"

2X4 OD4V

Ordering Information Example: 24-OD4V-2-32-T8 24

OD4V

Fixture Size

trim type

Fluorescent Recessed Volumetric

24 - 2’ X 4’

voltage1

(Consult factory for Slot T mounting option)

# lamps/lamp type

series OD4V-Oracle Dawn Direct/ Indirect

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8)

1-28-t5 2-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-2W

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

LUT-H3D LUT-H3D -

-

1

OTHER options

Lutron Eco-101

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

24

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OD4V-2-32-T8-MAS2 and 24-OD4V-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED VOLUMETRIC (CENTER MOUNT WITH LOUVER)

D A WN

OD4V

S H I P P I N G AVA I L A B L E

APPLICATION: Ideal for any application which requires high efficient lighting with minimum energy consumption such as educational institutions, office spaces, health care facilities, office complexes and retail stores. EFFICIENT SOLUTION: • High reflectance optical engine delivers main beam focus through the revolutionary flat High Transmission (HT) acrylic side diffusing panel with low brightness glow. Center blade louvers control light and distribute light to task. With 95% transmission and 89% haze, The result is extraordinary control and efficiency. OPTICAL SYSTEM: • A+ Rated high gloss white powder coat paint provides maximum distribution and visual comfort. PRODUCT FEATURES: • Up to 86% efficiency. • Dawn Series proprietary light lock system prevents light leakage at both ends of lamp shields. • Door Frame hinges for easy installation of lamps and hassle free maintenance. Ballast can be accessed from below the ceiling. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. Built in earthquake clips. • Construction of lamp shields conceals lamps and ballast access cover. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

16" 22" 4" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-11/16"

2X2

Ordering Information Example: 22-OD4V-2-17-T8 22

OD4V

OD4V

Fixture Size

trim type

voltage1

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series OD4V-Oracle Dawn Direct/ Indirect

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8)

1-14-t5 2-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OD4V-2-17-T8-MAS2 and 22-OD4V-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

-

-

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC3

LUT-EC3

LUT-EC3

LUT-EC3

-

-

-

-

LUT-H3D

LUT-H3D

-

-

LUT-H3D LUT-H3D -

-

1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem1

OTHER options

Lutron Eco-101 Lutron Tve1 Lutron Hi-Lume 3D

1

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Fluorescent Recessed Volumetric

22 - 2’ X 2’

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

25


Twilite INTRODUCING TWILITE A unique new lighting tool that provides uniform luminous distribution onto both the horizontal and vertical surfaces of the interior space. Twilite meets the current thinking in interior architectural lighting design utilizing a recessed direct/indirect lighting fixture design concept. Twilite is designed with perforated metal basket(s) and overlay that provides a “soft glow” low-brightness lighting effect that is ideal for general illumination purposes. Coupled with the need for high efficiency and effective lighting demand, Twilite is available with T-8 or T-5 fluorescent lamp and “state of the art” electronic ballast technology. Twilite captures the combined elegance of “art and science” with its sweeping curvilinear lines to create a perfect and desired interior lighting atmosphere. APPLICATION: Our Twilite product series provides a highly efficient light source that delivers a low brightness, glare free working environment. Ideal for use in offices, hospitals, retail stores, educational classrooms, banks, airports, corridors and other commercial interior spaces.

26

OCDI

NOVA

ONDI

Signature series

Celest

Signature series

Signature series

Signature series

SILHOUETTE

OSDI

ECLIPSE

OEDI


27


T8/T5, 2’ X 4’ FLUORESCENT RECESSED DIRECT/INDIRECT CENTER MOUNT STYLE

OD

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Twilite Series proprietary light lock system prevents light leakage at both ends of lamp shield. Steel side reflectors intersect with housing to ensure seamless appearance. • Lamp shield pivots down for easy installation of lamps. Ballast can be accessed from below the ceiling. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Lamp shield is 60% perforated white steel mesh, backed with high transmission white acrylic diffuser for optimum light efficiency, maximum glare control and lamp image prevention. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • Consult Factory for continuous row mounting. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

5-11/16" 23-11/16"

OD

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

47-13/16"

2X4

Ordering Information Example: 24-OD-3-32-T8 24

od

Fixture Size

trim type

Fluorescent Recessed Direct/Indirect Center Mount Style

24 - 2’ X 4’

voltage2

(Consult factory for Slot T mounting option)

# lamps/lamp type

series od-Oracle Direct/Indirect

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8) 3-32-t8 (3 lamps/32W/T8)

1-28-t5 2-28-t5 3-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (3 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank)1 -

(Blank) ADV-71 ADV-101

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

ADV-ROVR

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-2W1

-

-

Lutron Tu-Wire2

LUT-EC5 LUT-EC51

-

Lutron Ecosystem2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3 LUT-EC31

LUT-EC31

LUT-TVE1

1

-

LUT-H3D LUT-H3D -

-

1

1

2

OTHER options

Lutron Eco-102

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve2

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD1

Lutron Ecosystem (347V Only)2

2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

28

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OD-2-32-T8-MAS2 and 24-OD-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED DIRECT/INDIRECT CENTER MOUNT STYLE

OD

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Twilite Series proprietary light lock system prevents light leakage at both ends of lamp shield. Steel side reflectors intersect with housing to ensure seamless appearance. • Lamp shield pivots down for easy installation of lamps. Ballast can be accessed from below the ceiling. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Lamp shield is 60% perforated white steel mesh, backed with high transmission white acrylic diffuser for optimum light efficiency, maximum glare control and lamp image prevention. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard. • Consult Factory for continuous row mounting.

5-11/16" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects. 23-3/4"

2X2

Ordering Information Example: 22-od-3-17-t8 22

OD

od

Fixture Size

trim type

voltage2

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series od-Oracle Direct/Indirect

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8) 3-17-t8 (3 lamps/17W/T8)

1-14-t5 2-14-t5 3-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (3 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OD-2-17-T8-MAS2 and 22-OD-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR1

-

-

-

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire2

LUT-EC51 LUT-EC51

LUT-EC5

LUT-EC5

LUT-EC3 LUT-EC31

LUT-EC3

LUT-EC3

-

-

LUT-H3D

LUT-H3D

-

-

-

-

LUT-H3D LUT-H3D

1

-

-

2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem2

OTHER options

Lutron Eco-102 Lutron Tve2 Lutron Hi-Lume 3D

2

Lutron Ecosystem (347V Only)2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

29

Fluorescent Recessed Direct/Indirect Center Mount Style

22 - 2’ X 2’


T8/T5, 2’ X 4’ FLUORESCENT RECESSED DIRECT/INDIRECT SIDE MOUNT STYLE

ODS

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Twilite Series proprietary light lock system prevents light leakage at both ends of lamp shields. Steel side reflectors intersect with housing to ensure seamless appearance. • Dual lamp shields pivot down for easy installation of lamps. Ballast can be accessed from below the ceiling. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Lamp shield is 60% perforated white steel mesh, backed with high transmission white acrylic diffuser for optimum light efficiency, maximum glare control and lamp image prevention. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • Consult Factory for continuous row mounting. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

5-1/2" 23-11/16"

ODS

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

47-13/16"

2X4

Ordering Information Example: 24-ODS-2-32-T8 24

odS

Fixture Size

trim type

Fluorescent Recessed Direct/Indirect Side Mount Style

24 - 2’ X 4’

voltage2

(Consult factory for Slot T mounting option)

# lamps/lamp type

series ods-Oracle Side Basket Direct/ Indirect

2-32-t8 (2 lamps/32W/T8) 4-32-t8 (4 lamps/32W/T8)

# of ballast

2-28-t5 (2 lamps/28W/T5) 4-28-t5 (4 lamps/28W/T5) 2-54-t5ho (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-101

(Blank)1 -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

ADV-ESS1

-

-

-

ADV-ROVR

1

LUT-EHD

LUT-EHD

LUT-EHD

1

LUT-2W

-

1

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

ADV-ROVR

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC31 LUT-EC31

LUT-EC3

-

-

OTHER options

Lutron Eco-102

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve2

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)2

2

1- Requires 2 Ballasts for 4 lamps 2- Voltage must be specified for dimming ballast.

30

Up to 520 L. for T5

Advance Essential2

Lutron Tu-Wire

LUT-H3D LUT-H3D

Up to 1400 L. for T8 or BX

EMG-T5-520

Advance Rover2 2

1

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 700 L. for T5 or T5HO

Lutron Ecosystem2

1

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 1300 L. for T5 or T5HO

-

1

EMG-T8-BX-600

EMG-T5-T5HO-1300

2

-

DESCRIPTION Up to 450 L. for T8 or BX

Advance Optanium2

-

-

EMG-T8-BX-450

EMG-T5-T5HO-700

LUT-EC51 LUT-EC51 LUT-TVE1

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-ODS-2-32-T8-MAS2 and 24-ODS-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED DIRECT/INDIRECT SIDE MOUNT STYLE

ODS

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Twilite Series proprietary light lock system prevents light leakage at both ends of lamp shields. Steel side reflectors intersect with housing to ensure seamless appearance. • Dual lamp shields pivot down for easy installation of lamps. Ballast can be accessed from below the ceiling. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Lamp shield is 60% perforated white steel mesh, backed with high transmission white acrylic diffuser for optimum light efficiency, maximum glare control and lamp image prevention. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard. • Consult Factory for continuous row mounting.

5-1/2" 23-3/4"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects. 23-3/4"

2X2

Ordering Information Example: 22-ODS-2-17-t8 22

ODS

odS

Fixture Size

trim type

voltage2

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series ods-Oracle Side Basket Direct/Indirect

2-17-t8 (2 lamps/17W/T8) 4-17-t8 (4 lamps/17W/T8)

2-14-t5 4-14-t5 2-24-t5ho 2-40-BX

(2 lamps/14W/T5) (4 lamps/14W/T5) (2 lamps/24W/T5HO) (2 lamp/40W/BX TT)

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-ODS-2-17-T8-MAS2 and 22-ODS-2-17-T8-SAT

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens) order code

(For other lamp type, please consult factory)

BALLAST CONFIGURATION & CODE 17w/T8

14w/T5

24w/T5HO

40w/BX

Description

(Blank) EPS ADV-71 ADV-101

(Blank)1 -

(Blank) ADV-10

(Blank) EPS ADV-10

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

-

-

-

-

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS1

-

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR1

-

-

-

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire2

LUT-EC51 LUT-EC51

LUT-EC5

LUT-EC5

LUT-EC31 LUT-EC31

LUT-EC3

LUT-EC3

-

-

LUT-H3D

LUT-H3D

-

-

-

-

LUT-H3D LUT-H3D 1

-

1

-

2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem2

OTHER options

Lutron Eco-102 Lutron Tve2 Lutron Hi-Lume 3D

2

Lutron Ecosystem (347V Only)2

1- Requires 2 Ballasts for 4 lamps 2- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

31

Fluorescent Recessed Direct/Indirect Side Mount Style

22 - 2’ X 2’


T8/T5, 2’ X 4’ FLUORESCENT RECESSED DIRECT/INDIRECT CENTER MOUNT STYLE WITH LOUVER

OBLD

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Shiloh Series Louvers are designed to increase visual enhancement directly to the task while producing a glare free environment. • Proprietary light lock system prevents light leakage at both ends of lamp shield. Steel side reflectors intersect with housing to ensure seamless appearance. • Lamp shield pivots down for easy installation of lamps. Ballast can be accessed from below the ceiling. • Lamp shield is 2/3 60% perforated white mesh metal and 1/3 white louvers. • Louvers are baked white enamel and backed by diffusing shield to eliminate lamp image. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • Consult Factory for continuous row mounting. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

5-11/16" 23-11/16"

47-13/16"

2X4 OBLD

Ordering Information Example: 24-OBLD-3-32-T8 24

OBLD

Fixture Size

trim type

Fluorescent Recessed Direct/Indirect Center Mount Style

24 - 2’ X 4’

voltage2

(Consult factory for Slot T mounting option)

# lamps/lamp type

series obld-Oracle Straight Blade Louvers Direct/Indirect

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8) 3-32-t8 (3 lamps/32W/T8)

1-28-t5 2-28-t5 3-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (3 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank)1 -

(Blank) ADV-71 ADV-101

-

ADV-OPT

-

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

ADV-ROVR

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-2W1

-

-

Lutron Tu-Wire2

LUT-EC5 LUT-EC51

-

Lutron Ecosystem2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3 LUT-EC31

LUT-EC31

LUT-TVE1

1

-

LUT-H3D LUT-H3D -

-

1

1

2

OTHER options

Lutron Eco-102

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve2

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD1

Lutron Ecosystem (347V Only)2

2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

32

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OBLD-2-32-T8-MAS2 and 24-OBLD-2-32-T8-SAT

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED DIRECT/INDIRECT CENTER MOUNT STYLE WITH LOUVER

OBLD

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Shiloh Series Louvers are designed to increase visual enhancement directly to the task while producing a glare free environment. • Proprietary light lock system prevents light leakage at both ends of lamp shield. Steel side reflectors intersect with housing to ensure seamless appearance. • Lamp shield pivots down for easy installation of lamps. Ballast can be accessed from below the ceiling. • Lamp shield is 2/3 60% perforated white mesh metal and 1/3 white louvers. • Louvers are baked white enamel and backed by diffusing shield to eliminate lamp image. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard. • Consult Factory for continuous row mounting.

5-11/16" 23-11/16"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-3/4"

2X2

Ordering Information Example: 22-OBLD-3-17-t8 22

OBLD

oBLd

Fixture Size

trim type

voltage2

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type

series obld-Oracle Straight Blade Louvers Direct/Indirect

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8) 3-17-t8 (3 lamps/17W/T8)

1-14-t5 2-14-t5 3-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

(1 lamp/14W/T5) (2 lamps/14W/T5) (3 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ballast factor

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OBLD-2-17-T8-MAS2 and 22-OBLD-2-17-T8-SAT

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

Advance Optanium2

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR1

-

-

-

Advance Rover2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire2

LUT-EC51 LUT-EC51

LUT-EC5

LUT-EC5

LUT-EC3 LUT-EC31

LUT-EC3

LUT-EC3

-

-

LUT-H3D

LUT-H3D

-

-

-

-

LUT-H3D LUT-H3D

1

-

-

2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Ecosystem2

OTHER options

Lutron Eco-102 Lutron Tve2 Lutron Hi-Lume 3D

2

Lutron Ecosystem (347V Only)2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

33

Fluorescent Recessed Direct/Indirect Center Mount Style

22 - 2’ X 2’


34

OSDI

NOVA

ONDI

Signature series

Signature series

Signature series

SILHOUETTE

Signature series

Twilite Signature Series

Celest

OCDI

ECLIPSE

OEDI


WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

35


Signature Series ... Provides visual enhancement to compliment any contemporary or modern interior design 2’ X 4’ & 2’ X 2’ FLUORESCENT RECESSED DIRECT/INDIRECT APPLICATION: General illumination for health care facilities, educational institutions, airports, commercial offices, retail and many other applications. PRODUCT FEATURES: • Twilite Signature Series proprietary light lock system prevents light leakage at both ends of lamp shields. Steel side reflectors intersect with housing to ensure seamless appearance. • Lamp shield pivots down for easy installation of lamps. Ballast can be accessed from below the ceiling. •  Post Painted soft white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Lamp shield is offered with four decorative perforated metal patterns backed with white acrylic diffuser for optimum light efficiency and maximum glare control. • Up to 76% efficiency. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard. • Consult Factory for continuous row mounting. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

T8/T5 OD

5-11/16"

OEDI

CELEST

OCDI 5-11/16"

Signature series

Signature series

OSDI

ECLIPSE

Signature series

Fluorescent Recessed Direct/Indirect Signature Series

SILHOUETTE

Signature series

S H I P P I N G AVA I L A B L E

NOVA

ONDI

23-11/16"

23-11/16"

5-11/16" 23-11/16"

47-13/16"

23-3/4"

23-3/4"

36

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


Ordering Information Example: 22-oSdi-3-17-t8 22 Fixture Size 22 - 2’ X 2’

trim type

voltage2

(Consult factory for Slot T mounting option)

# lamps/lamp type

series OSdi Silhouette Oedi Eclipse

1-17-t8 (1 lamp/17W/T8) 2-17-t8 (2 lamps/17W/T8) 3-17-t8 (3 lamps/17W/T8)

1-14-t5 2-14-t5 3-14-t5 1-24-t5ho 2-24-t5ho 1-40-BX 2-40-BX

OCDi Celest ondi Nova

(1 lamp/14W/T5) (2 lamps/14W/T5) (3 lamps/14W/T5) (1 lamp/24W/T5HO) (2 lamps/24W/T5HO) (1 lamp/40W/BX TT) (2 lamps/40W/BX TT)

order code

BALLAST CONFIGURATION & CODE 14w/T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

ADV-ESS

-

-

-

ADV-ROVR

-

-

-

-

-

-

-

1

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

-

Advance Rover

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

Lutron Ecosystem H-Series2

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Lutron Tu-Wire

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

2

LUT-EC3 LUT-EC31

LUT-EC3

LUT-EC3

-

-

LUT-H3D

LUT-H3D

-

-

-

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Advance Optanium

-

-

EMG-T8-BX-600

Up to 700 L. for T5 or T5HO

LUT-EC5

LUT-H3D LUT-H3D

DESCRIPTION Up to 450 L. for T8 or BX

Up to 1300 L. for T5 or T5HO

-

1

EMG-T8-BX-450

EMG-T5-T5HO-1300

2

LUT-EC5

-

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

EMG-T5-T5HO-700

LUT-EC51 LUT-EC51 -

lampS installed

ballast factor

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OSDI-3-17-T8-MAS2 and 22-OSDI-3-17-T8-SAT

(Blank)-Grid

2

Lutron Ecosystem2

OTHER options

Lutron Eco-102

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve2 Lutron Hi-Lume 3D

2

Lutron Ecosystem (347V Only)

2

1- Requires 2 Ballasts for 3 or more lamps 2- Voltage must be specified for dimming ballast.

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

T8/T5 OD

Ordering Information Example: 24-OsDi-3-32-T8 24 Fixture Size

trim type

voltage2

(Consult factory for Slot T mounting option)

# lamps/lamp type

series OSdi Silhouette Oedi Eclipse

1-32-t8 (1 lamp/32W/T8) 2-32-t8 (2 lamps/32W/T8) 3-32-t8 (3 lamps/32W/T8)

OcDi Celest ondi Nova

1-28-t5 2-28-t5 3-28-t5 1-54-t5ho 2-54-t5ho

# of ballast

(1 lamp/28W/T5) (2 lamps/28W/T5) (3 lamps/28W/T5) (1 lamp/54W/T5HO) (2 lamps/54W/T5HO)

order code

BALLAST CONFIGURATION & CODE 28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank)1 -

(Blank) ADV-71 ADV-101

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

32w/T8

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OSDI-2-32-T8-MAS2 and 24-OSDI-2-32-T8-SAT

(Blank)-Grid

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO Up to 1300 L. for T5 or T5HO

-

ADV-OPT

-

Advance Optanium

EMG-T5-T5HO-1300

ADV-ESS

-

-

Advance Essential2

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

ADV-ROVR

Advance Rover

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EHD

LUT-EHD1

LUT-EHD1

Lutron Ecosystem H-Series2

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-2W1

-

-

Lutron Tu-Wire2

LUT-EC5 LUT-EC51

-

Lutron Ecosystem2

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3 LUT-EC31

LUT-EC31

LUT-TVE

1

-

LUT-H3D LUT-H3D1 -

-

2

-

2

OTHER options

Lutron Eco-102

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve

2

LUT-H3D

Lutron Hi-Lume 3D2

LUT-ECD

Lutron Ecosystem (347V Only)

1

2

1- Requires 2 Ballasts for 3 lamps 2- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor DCR - Dust Cover USA - Made in America Compliance

37

Fluorescent Recessed Direct/Indirect Signature Series

24 - 2’ X 4’


OHP

T8/T5, 2’ X 4’ FLUORESCENT RECESSED WHITE HIGH PERFORMANCE PARABOLIC S H I P P I N G AVA I L A B L E

UP TO

85%

EFFICIENCY 3-3/4" 23-3/4"

47-3/4"

2X4 OHP

APPLICATION: Due to its high efficiency and glare control, Oracle high performance parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 85% efficiency. • Due to its high efficiency and glare control, Oracle High Performance fixtures are the perfect choice for retail stores and any other retail applications. • 12 cell aluminum flat blade louvers (2 x 6 cell). • Cross blades are notched to allow lamps to nest into cells of louver for improved efficiency and are fitted with cam latches and T-hinge. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Louvers are manufactured from rigid high performance anodized Aluminium. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

Ordering Information Example: 24-OHP-2-32-T8-12-WH 24

OHP

Fixture Size

Fluorescent Recessed White High Performance Parabolic

24 - 2’ X 4’

trim type

voltage1

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type series MAS2-Master fixture w/ 2 oHp2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) ballast & 11 ft. flex Oracle High 2-54-t5ho (2 lamps/54W/T5HO) sAT-Satellite fixture w/o ballast Performance *must be ordered separately Flat Blade EX: 24-OHP-2-32-T8-MAS2 Louver Troffer and 24-OHP-2-32-T8-SAT

order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

# cells 12 - (2x6)

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

Description

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

-

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-2W

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

LUT-H3D LUT-H3D -

-

1

OTHER options

Lutron Eco-101

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D1

LUT-ECD

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

38

finish WH-White

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


39


40


T8/T5, 2’ X 2’ FLUORESCENT RECESSED WHITE HIGH PERFORMANCE PARABOLIC

OhP

S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle high performance parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 85% efficiency. • Due to its high efficiency and glare control, Oracle High Performance fixtures are the perfect choice for retail stores and any other retail applications. • 6 cell aluminum flat blade louvers (2 x 3 cell). • Cross blades are notched to allow lamps to nest into cells of louver for improved efficiency and are fitted with cam latches and T-hinge. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Louvers are manufactured from rigid high performance anodized Aluminium. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

UP TO

85%

EFFICIENCY 3-3/4" 23-3/4"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-3/4"

2X2

Ordering Information Example: 22-OHP-2-17-T8-6-WH 22

OHP

OHP

Fixture Size

trim type

voltage1

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF (Consult factory for 120 LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type series MAS2-Master fixture w/ 2 oHp2-17-t8 (2 lamps/17W/T8) 2-14-t5 (2 lamps/14W/T5) ballast & 11 ft. flex Oracle High 2-24-t5ho (2 lamps/24W/T5HO) sAT-Satellite fixture w/o ballast Performance 2-40-BX (2 lamps/40W/BX TT) *must be ordered separately Flat Blade EX: 22-OHP-2-17-T8-MAS2 Louver Troffer and 22-OHP-2-17-T8-SAT

finish WH-White

(Blank)-Grid

order code

BALLAST CONFIGURATION & CODE 14w/T5

6 - (2x3)

lampS installed (blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

17w/T8

# cells

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

24w/T5HO

40w/BX

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

(Blank) EPS ADV-10

-

-

-

-

Advance Optanium1

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

ADV-ESS

-

-

-

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

-

-

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Ecosystem H-Series

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC3

LUT-EC3

LUT-EC3

LUT-EC3

-

-

-

-

LUT-H3D

LUT-H3D

-

-

LUT-H3D LUT-H3D -

-

1

Lutron Ecosystem1 Lutron Eco-101 Lutron Tve1 Lutron Hi-Lume 3D1 Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

OTHER options 22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

41

Fluorescent Recessed White High Performance Parabolic

22 - 2’ X 2’


PRODUCT INFORMATION ALUMINUM PARABOLIC LOUVERS “DEEP CELL” 2-1/2” DEEP

CELL CONFIGURATIONS 1’x4’ Configurations

1 or 2 Lamp

14-op

2 Lamp

(1X6) 6 Cell

2’x2’ Configurations

(2X8) 16 Cell

2 or 3 Lamp

4 Lamp

T8/T5 OP

(3X3) 9 Cell

(4X4) 16 Cell

Parabolic Cell Configuration

22-op 2’x4’ Configurations

24-op

2 Lamp

2, 3 or 4 Lamp

(2X6) 12 Cell

(3X6) 18 Cell

4 Lamp

(4X8) 32 Cell

Aluminum Finishes: LD

Semi-Specular Silver/Low Iridescent

WH

Baked White Enamel

42

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

43


T8/T5, 2’ X 4’ FLUORESCENT RECESSED PARABOLIC WITH 2-1/2” DEEP LOUVERS (SPECIFICATION GRADE)

OP

S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle Parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 75% efficiency. • Black inside reveal provides floating louvers appearance. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Louvers are manufactured from rigid high performance anodized Aluminium & are fitted with cam latches and T-hinge to housing. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

4-5/8" 23-5/8" 48"

47-5/8"

2X4 OP

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

Ordering Information Example: 24-OP-3-32-T8-18-LD 24

OP

Fixture Size

trim type

Fluorescent Recessed Parabolic

24 - 2’ X 4’

voltage3

series op-Oracle Parabolic Troffer

(For other lamp type, please consult factory)

ballast factor

order code

finish

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

Description

EMG-T8-BX-600

Up to 600 L. for T8 or BX

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

(Blank) EPS ADV-7 ADV-102

(Blank)1 -

(Blank) ADV-71 ADV-101

-

ADV-OPT

-

Advance Optanium3

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

54w/T5HO

-

Advance Essential3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS2

-

ADV-ROVR

-

LUT-EHD2

LUT-EHD1

LUT-EHD1

LUT-2W1

-

-

Lutron Tu-Wire3

LUT-EC52 LUT-EC51

-

Lutron Ecosystem3

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC32 LUT-EC31

LUT-EC31

Lutron Eco-103

OTHER options

LUT-TVE1

-

LUT-H3D2 LUT-H3D1 -

-

ADV-ROVR2 Advance Rover3

-

Lutron Ecosystem H-Series3

Lutron Tve3

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

LUT-H3D1

Lutron Hi-Lume 3D3

LUT-ECD1

Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

44

# of ballast

LD -Diffuse Silver (Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast HBF- High BF 2 -2 Ballasts 120 (Consult factory for lampS installed Slot T mounting option) LBF- Low BF 277 347 *master/satellite (blank) - No lamps # lamps/lamp type MAS1-Master fixture w/ 1 L30K - 3000K 12 OR 18 cell 12 OR 18 cell ballast & 11 ft. flex L35K - 3500K 2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) MAS2-Master fixture w/ 2 L41K - 4100K 2-54-t5ho (2 lamps/54W/T5HO) 18 cell ballast & 11 ft. flex L50K - 5000K 3-32-t8 (3 lamps/32W/T8) # cells 18 cell sAT-Satellite fixture w/o ballast 3-28-t5 (3 lamps/28W/T5) 18 OR 32 CELL 12 - (2x6) 2 Lamp *must be ordered separately 4-32-t8 (4 lamps/32W/T8) 3-54-t5ho (3 lamps/54W/T5HO) 18 - (3x6) 2, 3, 4 Lamp EX: 24-OP-2-32-T8-MAS2 18 OR 32 CELL 32 - (4x8) 4 Lamp and 24-OP-2-32-T8-SAT 4-28-t5 (4 lamps/28W/T5) 4-54-t5ho (4 lamps/54W/T5HO) emergency battery pack options (L. = Lumens) (Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED PARABOLIC WITH 2-1/2” DEEP LOUVERS (SPECIFICATION GRADE)

OP

S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle Parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 75% efficiency. • Black inside reveal provides floating louvers appearance. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Louvers are manufactured from rigid high performance anodized Aluminium & are fitted with cam latches and T-hinge to housing. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

4-3/4" 23-1/2"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

24"

23-1/2"

2X2

Ordering Information Example: 22-OP-3-17-T8-9-LD 22

OP

OP

Fixture Size

trim type

voltage3

(Blank)-Grid (Consult factory for Slot T mounting option)

# lamps/lamp type 9 cell 9 cell series 2-17-t8 (2 lamps/17W/T8) 2-14-t5 (2 lamps/14W/T5) 3-17-t8 (3 lamps/17W/T8) 3-14-t5 (3 lamps/14W/T5) op-Oracle Parabolic 2-32-U6-t8 (2 lamps/32W/U6) 2-24-t5ho (2 lamps/24W/T5HO) 3-24-t5ho (3 lamps/24W/T5HO) Troffer 16 cell 4-17-t8 (4 lamps/17W/T8) 2-40-BX (2 lamps/40W/BX TT) 3-40-BX (3 lamps/40W/BX TT 16 cell 4-14-t5 (4 lamps/14W/T5) (For other lamp type, please consult factory) 4-24-t5ho (4 lamps/24W/T5HO)

BALLAST CONFIGURATION & CODE 17w/T8 (Blank) EPS ADV-72 ADV-102

32w/T8 (Blank) EPS ADV-7 ADV-10

14w/T5 (Blank)2 -

24w/T5HO (Blank)1 ADV-102

40w/BX (Blank)2 EPS1 ADV-101

-

-

-

-

-

ADV-ESS2

ADV-ESS

ADV-ROVR1 ADV-ROVR

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Essential3

-

Advance Rover3

-

Lutron Ecosystem H-Series3

-

LUT-2W

-

-

-

Lutron Tu-Wire3

LUT-EC51 LUT-EC5 LUT-EC51

LUT-EC51

LUT-EC52

LUT-EC32 LUT-EC3 LUT-EC31

LUT-EC31

LUT-EC32

-

-

LUT-H3D1

LUT-H3D2

-

-

Lutron Ecosystem3

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Eco-103

OTHER options

Lutron Tve3 Lutron Hi-Lume 3D3 Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

order code

EMG-T8-BX-T5-T5HO-3200

-

-

emergency battery pack options (L. = Lumens)

Up to 700 L. for T5 or T5HO

-

-

9 - (3x3) 2, 3 Lamp 16 - (3x4) 4 Lamp

Up to 1300 L. for T5 or T5HO

-

-

# cells

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

EMG-T5-T5HO-1300

-

LUT-H3D2 LUT-H3D2 LUT-H3D1

lampS installed

Advance Optanium3

-

-

finish LD -Diffuse Silver

EMG-T5-T5HO-700

LUT-EHD

LUT-TVE

ballast factor

Description Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

-

-

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OP-2-17-T8-MAS2 and 22-OP-2-17-T8-SAT

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance Special options are available

45

Fluorescent Recessed Parabolic

22 - 2’ X 2’


T8/T5, 1’ X 4’ FLUORESCENT RECESSED PARABOLIC WITH 2-1/2” DEEP LOUVERS (SPECIFICATION GRADE)

OP

S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle Parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 75% efficiency. • Black inside reveal provides floating louvers appearance. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Louvers are manufactured from rigid high performance anodized Aluminium & are fitted with cam latches and T-hinge to housing. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

5-1/2" 11-3/4"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects. 48"

1X4 OP

Ordering Information Example: 14-OP-2-32-T8-6-LD 14

OP

Fixture Size

trim type

Fluorescent Recessed Parabolic

14 - 1’ X 4’

voltage1

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for Slot T mounting option) LBF- Low BF 277 347 *master/satellite # lamps/lamp type MAS1-Master fixture w/ 1 6 cell 6 cell ballast & 11 ft. flex 1-32-t8 (1 lamp/32W/T8) 1-28-t5 (1 lamp/28W/T5) MAS2-Master fixture w/ 2 1-54-t5ho (1lamp/54W/T5HO) 6, 16 cell ballast & 11 ft. flex 2-32-t8 (2 lamps/32W/T8) 6, 16 cell sAT-Satellite fixture w/o ballast 2-28-t5 (2 lamps/28W/T5) *must be ordered separately 2-54-t5ho (2lamps/54W/T5HO) EX: 14-OP-2-32-T8-MAS2 and 14-OP-2-32-T8-SAT

finish LD -Diffuse Silver

(Blank)-Grid

series op-Oracle Parabolic Troffer

lampS installed

# cells

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

6 - (1x6) 1,2 Lamp 16 - (2x8) 2 Lamp

emergency battery pack options (L. = Lumens) (For other lamp type, please consult factory)

order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

(Blank)

-

-

EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5 Up to 700 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Ecosystem H-Series1

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

-

-

Lutron Tu-Wire

-

Lutron Ecosystem1

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

1

OTHER options

Lutron Eco-101

14FK - Flange Kit for 1’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

46

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 1300 L. for T5 or T5HO

LUT-EC5

-

EMG-T8-BX-600

EMG-T5-T5HO-1300

Advance Optanium1

LUT-2W

-

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T5-T5HO-700

LUT-EC5

LUT-H3D LUT-H3D

EMG-T8-BX-450

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 1’ X 4’ FLUORESCENT SURFACE MOUNT PARABOLIC WITH 2-1/2” DEEP LOUVERS

OSMP

S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle Parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 75% efficiency. • Black inside reveal provides floating louvers appearance. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. •  Louvers are manufactured from rigid high performance anodized Aluminium & are fitted with cam latches and T-hinge to housing. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Designed for seamless and hassle free surface mounted installations. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

5" 12-1/2"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects. 48-1/2"

1X4

Ordering Information Example: 14-OSMP-2-32-T8-6-LD 14

OSMP

OSMP

Fixture Size

voltage1

series osmp-Oracle Surface Mount Parabolic

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 LBF- Low BF 277 347 *master/satellite # lamps/lamp type MAS1-Master fixture w/ 1 6 cell 6 cell ballast & 11 ft. flex 1-32-t8 (1 lamp/32W/T8) 1-28-t5 (1 lamp/28W/T5) MAS2-Master fixture w/ 2 1-54-t5ho (1lamp/54W/T5HO) 6, 16 cell ballast & 11 ft. flex 2-32-t8 (2 lamps/32W/T8) 6, 16 cell sAT-Satellite fixture w/o ballast 2-28-t5 (2 lamps/28W/T5) *must be ordered separately 2-54-t5ho (2lamps/54W/T5HO) EX: 14-OSMP-2-32-T8-MAS2 and 14-OSMP-2-32-T8-SAT

finish LD -Diffuse Silver

lampS installed

# cells

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

6 - (1x6) 1,2 Lamp 16 - (2x8) 2 Lamp

emergency battery pack options (L. = Lumens) (For other lamp type, please consult factory)

order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

Description

(Blank)

-

-

EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Advance Optanium1

ADV-ESS

-

-

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5 Up to 700 L. for T5 or T5HO

Advance Essential1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Rover

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Ecosystem H-Series1

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

1

-

-

Lutron Tu-Wire

-

Lutron Ecosystem1

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

1

OTHER options

Lutron Eco-101 Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 1300 L. for T5 or T5HO

LUT-EC5

-

EMG-T8-BX-600

EMG-T5-T5HO-1300

LUT-2W

-

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T5-T5HO-700

LUT-EC5

LUT-H3D LUT-H3D

EMG-T8-BX-450

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

FBF - Internal Fast Blow Fuse C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit)

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

Special options are available

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

47

Fluorescent Surface Mount Parabolic

14 - 1’ X 4’


OSMP

T8/T5, 2’ X 4’ FLUORESCENT SURFACE MOUNT PARABOLIC WITH 2-1/2” DEEP LOUVERS S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle Parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 75% efficiency. • Black inside reveal provides floating louvers appearance. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. •  Louvers are manufactured from rigid high performance anodized Aluminium & are fitted with cam latches and T-hinge to housing. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Designed for seamless and hassle free surface mounted installations. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

5" 24-1/2"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects. 48-1/2"

2X4 OSMP

Ordering Information Example: 24-OSMP-3-32-T8-18-LD 24

OsmP

Fixture Size

voltage3

Fluorescent Surface Mount Parabolic

24 - 2’ X 4’

series osmp-Oracle Surface Mount Parabolic

(For other lamp type, please consult factory)

ballast factor

order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

(Blank) EPS ADV-7 ADV-102

(Blank)1 -

(Blank) ADV-71 ADV-101

-

ADV-OPT

ADV-ESS2

-

ADV-ROVR

-

LUT-EHD2 LUT-EHD1 LUT-2W1

-

LUT-EC52 LUT-EC51 LUT-EC32 LUT-EC31 LUT-TVE1

-

54w/T5HO Description

finish

-

-

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

-

Advance Optanium3

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

-

Advance Essential3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ROVR2 Advance Rover3 LUT-EHD1

Lutron Ecosystem H-Series3

-

Lutron Tu-Wire3

-

Lutron Ecosystem3

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

OTHER options

LUT-EC31 Lutron Eco-103 -

Lutron Tve3

FBF - Internal Fast Blow Fuse C3 - 6’ 3-wire Flex Cable (Single Circuit)

LUT-H3D2 LUT-H3D1 LUT-H3D1 Lutron Hi-Lume 3D3 LUT-ECD1 Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

48

# of ballast

LD -Diffuse Silver (Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 lampS installed LBF- Low BF 277 347 *master/satellite (blank) - No lamps # lamps/lamp type MAS1-Master fixture w/ 1 L30K - 3000K 12 OR 18 cell 12 OR 18 cell ballast & 11 ft. flex L35K - 3500K 2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) MAS2-Master fixture w/ 2 L41K - 4100K 2-54-t5ho (2 lamps/54W/T5HO) 18 cell ballast & 11 ft. flex L50K - 5000K 3-32-t8 (3 lamps/32W/T8) # cells 18 cell sAT-Satellite fixture w/o ballast 3-28-t5 (3 lamps/28W/T5) 18 OR 32 CELL 12 - (2x6) 2 Lamp *must be ordered separately 4-32-t8 (4 lamps/32W/T8) 3-54-t5ho (3 lamps/54W/T5HO) 18 - (3x6) 2, 3, 4 Lamp EX: 24-OSMP-3-32-T8-MAS2 18 OR 32 CELL 32 - (4x8) 4 Lamp and 24-OSMP-3-32-T8-SAT 4-28-t5 (4 lamps/28W/T5) 4-54-t5ho (4 lamps/54W/T5HO) emergency battery pack options (L. = Lumens)

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit)

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

Special options are available

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT SURFACE MOUNT PARABOLIC WITH 2-1/2” DEEP LOUVERS

OSMP

S H I P P I N G AVA I L A B L E

APPLICATION: Due to its high efficiency and glare control, Oracle Parabolic fixtures are the perfect choice for educational institutions, health care facilities, department stores and any other retail application. PRODUCT FEATURES: • Up to 75% efficiency. • Black inside reveal provides floating louvers appearance. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. •  Louvers are manufactured from rigid high performance anodized Aluminium & are fitted with cam latches and T-hinge to housing. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Designed for seamless and hassle free surface mounted installations. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

5" 24-1/2"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

24-1/2"

2X2

Ordering Information Example: 22-OSMP-3-17-T8-9-LD 22

OSMP

OsmP

Fixture Size

voltage3

# lamps/lamp type 9 cell 9 cell series 2-17-t8 (2 lamps/17W/T8) 2-14-t5 (2 lamps/14W/T5) 3-17-t8 (3 lamps/17W/T8) 3-14-t5 (3 lamps/14W/T5) osmpOracle 2-32-U6-t8 (2 lamps/32W/U6) 2-24-t5ho (2 lamps/24W/T5HO) 3-24-t5ho (3 lamps/24W/T5HO) Surface 16 cell 4-17-t8 (4 lamps/17W/T8) 2-40-BX (2 lamps/40W/BX TT) Mount 3-40-BX (3 lamps/40W/BX TT Parabolic 16 cell 4-14-t5 (4 lamps/14W/T5) (For other lamp type, please consult factory) 4-24-t5ho (4 lamps/24W/T5HO)

BALLAST CONFIGURATION & CODE 17w/T8 (Blank) EPS ADV-72 ADV-102

32w/T8 (Blank) EPS ADV-7 ADV-10

14w/T5 (Blank)2 -

24w/T5HO (Blank)1 ADV-101

40w/BX (Blank)2 EPS1 ADV-101

-

-

-

-

-

ADV-ESS2

ADV-ESS

-

-

-

-

ADV-ROVR1 ADV-ROVR

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

Advance Essential3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

-

Advance Rover3

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-2W

-

-

-

Lutron Tu-Wire3

LUT-EC51 LUT-EC5 LUT-EC51

LUT-EC51

LUT-EC52

LUT-EC32 LUT-EC3 LUT-EC31

LUT-EC31

LUT-EC32

-

-

LUT-H3D1

LUT-H3D2

-

-

Lutron Ecosystem3

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Eco-103

OTHER options

Lutron Tve3 Lutron Hi-Lume 3D3 Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

order code

-

-

-

emergency battery pack options (L. = Lumens)

Up to 700 L. for T5 or T5HO

Lutron Ecosystem H-Series3

-

9 - (3x3) 2, 3 Lamp 16 - (3x4) 4 Lamp

Up to 1300 L. for T5 or T5HO

-

-

# cells

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

EMG-T5-T5HO-1300

-

LUT-H3D2 LUT-H3D2 LUT-H3D1

lampS installed

Advance Optanium3

-

-

finish LD -Diffuse Silver

EMG-T5-T5HO-700

LUT-EHD

LUT-TVE

ballast factor

Description Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

-

-

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 LBF- Low BF 277 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OSMP-3-17-T8-MAS2 and 22-OSMP-3-17-T8-SAT

FBF - Internal Fast Blow Fuse C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit)

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance

Special options are available

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

49

Fluorescent Surface Mount Parabolic

22 - 2’ X 2’


ALUMINUM PARABOLIC LOUVERS -OPVDT SERIES-

VD LIGHTING BASICS T8/T5 OPvdt

Lighting Solution:

• Select luminaires that minimize intensity in the 55° or 65° to 90° zone. • In “vdt normal” spaces with a mix of paper and non-critical vdt tasks, the ies recommends that the luminous intensity in the lengthwise, crosswise and 45° vertical planes should not exceed*: 300 candelas at 65° from vertical 185 candelas at 75° from vertical 60 candelas at 85° or more from vertical • In “vdt intensive” spaces where the majority of the time is spent viewing the vdt, the ies recommends that the luminous intensity in the lengthwise, crosswise, and 45° vertical planes should not exceed*: 300 candelas at 55° from vertical 220 candelas at 65° from vertical 135 candelas at 75° from vertical 45 candelas at 85° from vertical • Select luminaires with shielding angles of at least 30° in all directions. • Design to a maximum of 50** maintained footcandles on the horizontal work plane. • Locate vdt terminals between rows of luminaires when possible.

Other Considerations:

VDT Basics

• Iridescence Phenomena, present on lighting sheet reflectors, is caused by the refraction of light by the thin anodic coating that produces either cancellation or reinforcement of certain wavelengths of light. This “rainbow effect” appears primarily as various shades of green and pink that can change color at different viewing angles. • Iridescence has always been present on lighting sheet reflectors, but to a very subtle, often un-noticeable degree with the traditional fluorescent light sources that emitted a broad spectrum of light. With the introduction of fluorescent light sources that utilize rare-earth phosphors and emit distinct wavelengths of light, the phenomena of iridescence has been intensified and has become an aesthetic problem to the user. It should be recognized that the presence of iridescence does not detract from the optical performance of the lighting sheet reflector. • Unfortunately, there is currently no quantitative way to measure iridescence, so we are left with a purely subjective evaluation of what is objectionable and this can vary from individual to individual. • Low iridescence aluminum is recommended for use with T8, compact fluorescent TT5, and other tri-phosphor lamps.

50

WWW.ORACLELIGHTING .COM

S IE

The blades of a parabolic louver provide a physical cut-off in the same way as in an “egg-crate” louver, however, a parabolic louver with a specular silver finish reflects all light from its curved blades at an angle equal to or less than the louver cut-off angle

RP1

IES RECOMMENDED PRACTICE FOR LIGHTING OFFICES CONTAINING COMPUTER VISUAL DISPLAY TERMINALS

P1 R

• Windows should be treated with blinds or curtains to eliminateexcessive brightness. • Most vdt terminals may be tilted (up or down) or turned (side to side) to minimize reflected glare. • White clothing worn by operator may cause some loss of contrast on screen. • Negative contrast monitors (dark detail on a light background) frequently make reflected glare less noticeable. • Monitor design (screen curvature or flat screen, screen reflectance properties, etc.) can make significant differences in visual performance. • Use of screen filters supplied by manufacturers of visual display terminals helps to reduce screen glare. • Partitions may be located as needed to reduce reflections from windows or luminaires. Source: iesna rp-1 (2004) recommended practice for lighting offices containing computer visual display terminals. *These values are candlepower rather then luminance values as in previous recommendations. **Illuminating engineering society of north America (iesna) recommended level.

Louver Iridescence:

ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA

CEILING MOUNT

SHIELDED ZONE

OPTICAL CUT-OFF ANGLE LAMP CUT-OFF ANGLE

LOUVER CUT-OFF ANGLE

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


PRODUCT INFORMATION ALUMINUM PARABOLIC LOUVERS VDT (MEDIUM CELL) 1-1/2” DEEP CELL CONFIGURATION 24-OPVDT

2’x4’ Configurations

PRODUCT FEATURES: :: Designed to fit shallower fixtures for reduced plenum depths :: VDT compatible 0

:: IES RP1 standard requires 36 shielding 105

2X4 cell

49

2X2 cell

45

1X4 cell

:: Louver cell depth is 1 ½

1-1/2” (7X15) 105 Cell 360 Shielding 2-1/2”x2-1/2”x1-1/2”

(6X13) 78 Cell 300 Shielding 3”x3”x1-1/2”

:: Door frame assembly

22-OPVDT

2’x2’ Configurations T8/T5 OPvdt

(6X6) 36 Cell 3”x1-1/2”

1’x4’ Configurations

(2X13) 26 Cell

(3X13) 39 Cell

VDT Cell Configuration

14-OPVDT

(7X7) 49 Cell 2-1/2”x2-1/2”

(3X15) 45 Cell

Aluminum Finishes:

Reflectivity %

LD(Diffuse Silver) Semi-Specular Silver/Low Irradescent

88%

SI(Specular Silver) Specular Silver/Low Irradescent

92%

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

51


OPVDT

T8/T5, 2’ X 4’ FLUORESCENT RECESSED PARABOLIC WITH 1-1/2” DEEP LOUVERS

APPLICATION: Due to its high glare control, Oracle Parabolic VDT fixtures are the perfect choice for conventional and open landscape interior office applications. PRODUCT FEATURES: • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  VDT louvers are designed to dramatically reduce glare and brightness on the computer screen. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

4-5/8" 23-5/8"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

48"

47-5/8"

2X4 OPVDT

Ordering Information Example: 24-OPvdt-3-32-T8-78-LD 24

OPVDT

Fixture Size

Fluorescent Recessed Parabolic

24 - 2’ X 4’

trim type

voltage3

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type series MAS2-Master fixture w/ 2 opVDT2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) ballast & 11 ft. flex Oracle 3-32-t8 (3 lamps/32W/T8) 3-28-t5 (3 lamps/28W/T5) sAT-Satellite fixture w/o ballast Parabolic VDT 4-32-t8 (4 lamps/32W/T8) 4-28-t5 (4 lamps/28W/T5) *must be ordered separately 2-54-t5ho (2 lamps/54W/T5HO) EX: 24-OPVDT-3-32-T8-MAS2 3-54-t5ho (3 lamps/54W/T5HO) and 24-OPVDT-3-32-T8-SAT 4-54-t5ho (4 lamps/54W/T5HO)

finish LD -Diffuse Silver

(Blank)-Grid

lampS installed

# cells

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

78 - (6x13) 105 - (7x15)

emergency battery pack options (L. = Lumens) order code

(For other lamp type, please consult factory)

BALLAST CONFIGURATION & CODE

DESCRIPTION Up to 450 L. for T8 or BX

Description

EMG-T8-BX-600

Up to 600 L. for T8 or BX

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

-

Advance Optanium3

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

-

Advance Essential3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

32w/T8

28w/T5

(Blank) EPS ADV-7 ADV-102

(Blank)1 -

(Blank) ADV-71 ADV-101

-

ADV-OPT

54w/T5HO

ADV-ESS2

-

ADV-ROVR

-

LUT-EHD2

LUT-EHD1

LUT-EHD1

LUT-2W1

-

-

Lutron Tu-Wire3

LUT-EC52 LUT-EC51

-

Lutron Ecosystem3

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

LUT-EC32 LUT-EC31

LUT-EC31

Lutron Eco-103

OTHER options

LUT-TVE1

-

LUT-H3D2 LUT-H3D1 -

-

ADV-ROVR2 Advance Rover3

-

Lutron Ecosystem H-Series3

Lutron Tve3

LUT-H3D1

Lutron Hi-Lume 3D3

LUT-ECD1

Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

52

EMG-T8-BX-450

WWW.ORACLELIGHTING .COM

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED PARABOLIC WITH 1-1/2” DEEP LOUVERS

OPVDT

APPLICATION: Due to its high glare control, Oracle Parabolic VDT fixtures are the perfect choice for conventional and open landscape interior office applications. PRODUCT FEATURES: • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  VDT louvers are designed to dramatically reduce glare and brightness on the computer screen. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard. 4-3/4" LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-1/2" 24"

23-1/2"

2X2

Ordering Information Example: 22-OPvdt-3-17-T8-36-LD 22

OPVDT

Fixture Size

trim type

voltage3

# of ballast

ballast factor

finish

LD -Diffuse Silver (Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF (Consult factory for 120 lampS installed LBF- Low BF 277 Slot T mounting option) 347 *master/satellite (blank) - No lamps MAS1-Master fixture w/ 1 L30K - 3000K ballast & 11 ft. flex L35K - 3500K # lamps/lamp type series MAS2-Master fixture w/ 2 L41K - 4100K 2-17-t8 (2 lamps/17W/T8) 2-14-t5 (2 lamps/14W/T5) opVDTballast & 11 ft. flex # cells L50K - 5000K 3-17-t8 (3 lamps/17W/T8) 3-14-t5 (3 lamps/14W/T5) Oracle sAT-Satellite fixture w/o ballast 4-17-t8 (4 lamps/17W/T8) 4-14-t5 (4 lamps/14W/T5) Parabolic 36 - (6x6) *must be ordered separately 2-32-U6-T8 (2 lamps/32W/T8) 2-24-t5ho (2 lamps/24W/T5HO) VDT 49 - (7x7) EX: 22-OPVDT-3-17-T8-MAS2 3-24-t5ho (3 lamps/24W/T5HO) and 22-OPVDT-3-17-T8-SAT 4-24-t5ho (4 lamps/24W/T5HO) 2-40-BX (2 lamps/40W/BX TT) emergency battery pack options (L. = Lumens) 3-40-BX (3 lamps/40W/BX TT) (For other lamp type, please consult factory) order code DESCRIPTION Up to 450 L. for T8 or BX EMG-T8-BX-450 BALLAST CONFIGURATION & CODE Up to 600 L. for T8 or BX EMG-T8-BX-600 17w/T8 32w/T8 14w/T5 24w/T5HO 40w/BX Description Up to 700 L. for T8 or BX EMG-T8-BX-700 (Blank) (Blank) (Blank) Electronic Instant Start (Blank)-Grid

EPS ADV-72 ADV-102

EPS ADV-7 ADV-10

(Blank)2 -

(Blank)1 ADV-101,2

EPS2 ADV-101

-

-

-

-

-

ADV-ESS2

ADV-ESS

ADV-ROVR1 ADV-ROVR

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

-

-

Advance Essential3

-

-

-

Advance Rover3

-

-

-

Lutron Ecosystem H-Series3

-

LUT-2W

-

-

-

Lutron Tu-Wire3

LUT-EC51 LUT-EC5 LUT-EC51

LUT-EC51

LUT-EC52

LUT-EC32 LUT-EC3 LUT-EC31

LUT-EC31

LUT-EC32

-

-

LUT-H3D1

LUT-H3D2

-

-

-

LUT-H3D2 LUT-H3D2 LUT-H3D1 -

-

-

Lutron Ecosystem3

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

Lutron Eco-103

OTHER options

Lutron Tve3 Lutron Hi-Lume 3D3 Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

Up to 520 L. for T5

Advance Optanium3

LUT-EHD

LUT-TVE

Up to 1400 L. for T8 or BX

EMG-T5-520 EMG-T5-T5HO-700

-

-

EMG-T8-BX-1400

Electronic Program Start Advance Mark-73 Advance Mark-103

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance Special options are available

53

Fluorescent Recessed Parabolic

22 - 2’ X 2’

OPVDT


OPVDT

T8/T5, 1’ X 4’ FLUORESCENT RECESSED PARABOLIC WITH 1-1/2” DEEP LOUVERS

APPLICATION: Due to its high glare control, Oracle Parabolic VDT fixtures are the perfect choice for conventional and open landscape interior office applications. PRODUCT FEATURES: • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  VDT louvers are designed to dramatically reduce glare and brightness on the computer screen. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

5-1/2" 11-3/4"

48"

1X4 OPVDT

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

Ordering Information Example: 14-OPvdt-1-32-T8-26-LD 14

OPvdt

Fixture Size

Fluorescent Recessed Parabolic

14 - 1’ X 4’

trim type

voltage1

# of ballast

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type series MAS2-Master fixture w/ 2 ballast opVDT1-32-t8 (1 lamp/32W/T8) 1-28-t5 (1 lamp/28W/T5) & 11 ft. flex Oracle 2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) sAT-Satellite fixture w/o ballast Parabolic VDT 1-54-t5ho (1lamp/54W/T5HO) EX: 14-OPVDT-2-32-T8-MAS2 and 2-54-t5ho (2lamps/54W/T5HO) 14-OPVDT-2-32-T8-SAT

order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

(Blank)

-

-

EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5 Up to 700 L. for T5 or T5HO Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Ecosystem H-Series1

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

many other bodine and iota emergency packs are available, please consult factory. visit www.bodine.com or www.iotaengineering.com for more details.

ADV-OPT

-

Advance Optanium

-

-

Advance Essential1

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

1

Advance Rover

1

LUT-2W

-

-

Lutron Tu-Wire

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

-

-

26 - (2x13) 39 - (3x13) 45 - (3x15)

EMG-T5-T5HO-1300

-

-

# cells

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

EMG-T5-T5HO-700

ADV-ESS

LUT-H3D LUT-H3D

lampS installed

emergency battery pack options (L. = Lumens)

(For other lamp type, please consult factory)

1

OTHER options

Lutron Eco-101

14FK - Flange Kit for 1’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD

Lutron Ecosystem (347V Only)1

1

1- Voltage must be specified for dimming ballast.

54

finish LD -Diffuse Silver

(Blank)-Grid

WWW.ORACLELIGHTING .COM

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


55


FF US ER LE NS

&

DI

LENS AND DIFFUSER OPTIONS A-12/ FEMALE CONICAL PRISMATIC LENS

This quality extruded acrylic lens provides very good low brightness control with excellent light output. The lens utilizes a diagonally oriented prism pattern with square inversed prisms that are optically designed to provide excellent light control. The A12 pattern has become a standard in the industry offering economy with quality. Thickness .100 (Part# A12) .125 (Part# A125)

ASW-SMOOTH WHITE- STIPPLE FINISH Smooth White Flat Sheet provides improved glare control and reduced lamp image. These extruded smooth and crepe diffusing panels are available in acrylic providing evenly illuminated lighting enclosures while reducing shadows and reflected glare. Thickness .080 (Part# ASW)

A-15-FEMALE CONICAL PRISMATIC LENS The 15 is an extruded acrylic lens with a large 3/8 square pattern design that renders a bold, well ordered look that hides the lamps from direct view. The recessed female conical pattern provides maximum strength to weight ratios for oversized areas up to 48” square. The lens is an ideal prismatic lens where the bolder prism pattern is desired. Thickness .200 (Part# A15)

A-19- MALE CONICAL PRISMATIC LENS This is the finest in extruded acrylic lenses offering superior lamp obscuration and excellence source brightness control. The small square base male prisms are organized in a parallel pattern providing a discrete and tailored appearance. The 19 lens offers the crisp appearance and the optical preciseness often associated with injection molded lenses with the economies of the extruded lens. Thickness

56

.156 (Part# A19)

W W W. O R ACLE LI G HTIN G . CO M

• T EL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 -375-3333


AS PL C TI

PLASTIC LOUVER OPTIONS SILVER SPECULAR

ER UV LO

PCL1 is the internationally recognized industry standard small cell injection molded plastic parabolic louver. The fixture style parts include an integral flange that may be used full size or trimmed to achieve lesser overall dimensions. The style 4X is molded to a generic size that fits many fixtures without trimming.

48°

42°

52% of fixture lumens

VCP-Ceiling .400”

HEIGHT

MEAN

MODE

8.5’

.99

.99

10’

.98

.98

5/8”X5/8”X3/8”plastic louvers

.625”

PCL2 is the industry standard 1-1/2” x 1-1/2” x 1” (38 x 38 x 25,4mm) injection molded plastic parabolic louver. This internationally accepted product satisfies the demands of both efficiency and luminance control. Molded in a number of configurations PCL2 is adaptable to a wide range applications. Style 5 louvers have smaller body dimensions and are designed to accommodate smaller overall sizes and some difficult to fit fixtures.

52° 64% of fixture lumens

38°

VCP-Ceiling 1.00“

HEIGHT

MEAN

MODE

8.5’

.98

.99

10’

.99

.99

1-1/2”X1-1/2”X1” plastic louver

1.50“

PCL3 with mid-sized 3/4” x 3/4” x 1/2” (19 x 19 x 12,2mm) cells provide 35 degree shielding and maintains energy saving efficiencies. PCL3 reflects our commitment to high efficiency louvers by offering not only an unsurpassed optically engineered wedge back design but also the molded louver configurations that will maximize energy budgeted applications. For the world market PCL3 is molded in a versatile unflanged metric panel size. 55° 78% of Fixture Lumens

35°

VCP-Ceiling .48”

HEIGHT

MEAN

MODE

8.5’

.95

.97

10’

.91

.93

3/4”X3/4”X1/2” plastic louver

.75”

PCL4 combines superior beauty, light control and the highest light transmission in a plastic louver. This larger cell louver offers the highest efficiency and coefficient of utilization of any member of the PCL4 family. The PCL4 is ideal in high ceiling applications, offices with greater spacing between light fixtures, corridors, public and general offices, and retail merchandising applications where “light for selling” is critical. Outstanding for use where broader Light distribution is desired

1.1/2“

Luminaire Efficiency to 67.8% Coefficient of Utilization to .74 Visual Comfort Probability to 88

WWW.ORAC L ELIG HT ING . CO M

3“

• T EL : 1 - 8 7 7 - 3 7 5 - 5 5 5 5

3”X3”X1-1/2” plastic louver

• FA X : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

57


T8/T5, 2’ X 4’ FLUORESCENT RECESSED SPECIFICATION GRADE TROFFER

OT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial applications including schools, offices & retail spaces. PRODUCT FEATURES: • Up to 80% efficiency. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Constructed of one-piece ribbed unitized housing and corners that inter-lock, preventing aesthetic damage to luminaire. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Clear 0.100” thick #12 pattern acrylic lens, standard. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

3-3/4" 23-3/4"

48"

2X4 OT

Ordering Information Example: 24-OT-3-32-T8-A12 24

ot trim type

Fixture Size

Fluorescent Recessed Specification Grade Troffer

24 - 2’ X 4’

voltage3

# of ballast

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type MAS2-Master fixture w/ 2 2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) ballast & 11 ft. flex 3-32-t8 (3 lamps/32W/T8) 3-28-t5 (3 lamps/28W/T5) sAT-Satellite fixture w/o ballast 4-32-t8 (4 lamps/32W/T8) 4-28-t5 (4 lamps/28W/T5) *must be ordered separately 2-54-t5ho (2 lamps/54W/T5HO) EX: 24-OT-3-32-T8-MAS2 3-54-t5ho (3 lamps/54W/T5HO) and 24-OT-3-32-T8-SAT 4-54-t5ho (4 lamps/54W/T5HO)

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank)-Grid

series ot-Oracle Troffer

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

(For other lamp type, please consult factory)

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

32w/T8

28w/T5

Description

order code

(Blank) EPS ADV-7 ADV-102

(Blank)1 -

(Blank) ADV-71 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

-

ADV-OPT

-

Advance Optanium3

EMG-T5-520

Up to 520 L. for T5

ADV-ESS2

-

-

Advance Essential3

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

ADV-ROVR

-

Up to 1300 L. for T5 or T5HO

LUT-EHD2

LUT-EHD1

LUT-EHD1

EMG-T5-T5HO-1300

-

-

Lutron Tu-Wire3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

LUT-2W1

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EC52 LUT-EC51

-

Lutron Ecosystem3

EMG-SD-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-EC32 LUT-EC31

LUT-EC31

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-TVE1

54w/T5HO

ADV-ROVR2 Advance Rover3

-

-

LUT-H3D LUT-H3D 2

-

1

-

Lutron Ecosystem H-Series3

Lutron Eco-103

OTHER options

Lutron Tve3

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD1

Lutron Ecosystem (347V Only)3

1

3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

58

WWW.ORACLELIGHTING .COM

24FK - Flange Kit for 2’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse 24ALDF - Aluminum Door frame

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance GDF - Gasketed Door Frame Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED SPECIFICATION GRADE TROFFER

OT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial applications including schools, offices & retail spaces. PRODUCT FEATURES: • Up to 80% efficiency. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Constructed of one-piece ribbed unitized housing and corners that inter-lock, preventing aesthetic damage to luminaire. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Clear 0.100” thick #12 pattern acrylic lens, standard. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

3-3/4" 23-3/4"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

23-3/4"

2X2

Ordering Information Example: 22-OT-3-17-t8-A12 22

OT trim type

Fixture Size

voltage3

# of ballast

32W/31w/T8 14w/T5 (Blank) EPS (Blank)2 ADV-7 ADV-10 -

(blank) - No lamps L30K - 30K L41K- 41K L35K - 35K L50K- 50K

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE 17w/T8 (Blank) EPS ADV-72 ADV-102

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF (Consult factory for 120 LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type series MAS2-Master fixture w/ 2 2-14-t5 (2 lamps/14W/T5) ot-Oracle 2-17-t8 (2 lamps/17W/T8) ballast & 11 ft. flex 3-14-t5 (3 lamps/14W/T5) Troffer 3-17-t8 (3 lamps/17W/T8) sAT-Satellite fixture w/o ballast 4-14-t5 (4 lamps/14W/T5) 4-17-t8 (4 lamps/17W/T8) *must be ordered separately 2-32-U6-T8 (2 lamps/32W/T8) 2-24-t5ho (2 lamps/24W/T5HO) EX: 22-OT-3-17-T8-MAS2 and 2-31-U1.5-T8 (2 lamps/31W/T8) 3-24-t5ho (3 lamps/24W/T5HO) 22-OT-3-17-T8-SAT 3-31-U1.5-T8 (3 lamps/31W/T8) 4-24-t5ho (4 lamps/24W/T5HO) 2-40-BX (2 lamps/40W/BX TT) (For other lamp type, please consult factory) 3-40-BX (3 lamps/40W/BX TT) (Blank)-Grid

24w/T5HO (Blank)1 ADV-102

40w/BX (Blank)2 EPS1 ADV-101

Description Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

order code EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX Up to 520 L. for T5

-

-

-

-

-

Advance Optanium3

EMG-T5-520

ADV-ESS2

ADV-ESS

-

-

-

Advance Essential3

Up to 700 L. for T5 or T5HO

ADV-ROVR1

ADV-ROVR

-

-

-

EMG-T5-T5HO-700

Advance Rover3

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

LUT-EHD

-

-

-

Lutron Ecosystem H-Series3

-

LUT-2W1

-

-

-

Lutron Tu-Wire3

LUT-EC51

LUT-EC5

LUT-EC51

LUT-EC51

LUT-EC52

Lutron Ecosystem3

LUT-EC32

LUT-EC3

LUT-EC31

LUT-EC31

LUT-EC32

Lutron Eco-103

-

LUT-TVE1

-

-

-

LUT-H3D2

LUT-H3D2

LUT-H3D1

LUT-H3D1

LUT-H3D2

-

-

-

-

-

Lutron Tve3 Lutron Hi-Lume 3D3 Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

OTHER options 22FK - Flange Kit for 2’ X 2’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse 22ALDF - Aluminum Door frame

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance GDF - Gasketed Door Frame Special options are available

59

Fluorescent Recessed Specification Grade Troffer

22 - 2’ X 2’

OT


T8/T5, 1’ X 4’ FLUORESCENT RECESSED SPECIFICATION GRADE TROFFER

OT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial applications including schools, offices & retail spaces. PRODUCT FEATURES: • Up to 80% efficiency. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Constructed of one-piece ribbed unitized housing and corners that inter-lock, preventing aesthetic damage to luminaire. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Clear 0.100” thick #12 pattern acrylic lens, standard. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

3-3/4" 11-3/4"

48"

1X4 OT

Ordering Information Example: 14-OT-1-32-T8-A12 14

ot

Fixture Size

trim type

Fluorescent Recessed Specification Grade Troffer

14 - 1’ X 4’

voltage1

# of ballast

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type MAS2-Master fixture w/ 2 1-32-t8 (1 lamp/32W/T8) 1-28-t5 (1 lamp/28W/T5) ballast & 11 ft. flex 2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) sAT-Satellite fixture w/o ballast 1-54-t5ho (1 lamp/54W/T5HO) *must be ordered separately 2-54-t5hO (2 lamps/54W/T5HO) EX: 14-OT-2-32-T8-MAS2 and 14-OT-2-32-T8-SAT

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank)-Grid

series ot-Oracle Troffer

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

(For other lamp type, please consult factory)

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

order code

Description

(Blank)

-

-

EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Advance Optanium

ADV-ESS

-

-

Advance Essential1

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101 1

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Lutron Ecosystem H-Series1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Rover

1

LUT-2W

-

-

Lutron Tu-Wire

EMG-SD-T8-BX-T5-T5HO-1400

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-EC3

LUT-EC3

LUT-EC3

Lutron Eco-10

OTHER options

LUT-TVE

-

-

LUT-H3D LUT-H3D -

-

1

1

14FK - Flange Kit for 1’ X 4’ Fixture C3 - 6’ 3-wire Flex Cable (Single Circuit)

Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D1

LUT-ECD

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse 14ALDF - Aluminum Door frame

60

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance GDF - Gasketed Door Frame Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 1’ X 4’ FLUORESCENT RECESSED FLANGED SPECIFICATION GRADE TROFFER

OFT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial applications. PRODUCT FEATURES: • Up to 80% efficiency. • Fixture is designed to install into drywall and plaster frame style ceilings. The flange is designed to fit into ceiling up to 1” thick. • Adjustable wing hangers securely engage onto wood or metal joists in the ceiling plenum. • Adjustable wing hanger for safely securing fixture housing to wood or metal joists. Available with optional yoke hangers. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Supplied with Advance or Universal ballast standard. • Clear 0.100” thick #12 pattern acrylic lens, standard. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. • Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

4-3/4" 12-3/4"

24"

1X4

Ordering Information Example: 14-OFT-1-32-t8-A12 14

OFT

oFT

Fixture Size

trim type

voltage1

# of ballast

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF (Consult factory for 120 LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type MAS2-Master fixture w/ 2 ballast 1-32-t8 (1 lamp/32W/T8) 1-28-t5 (1 lamp/28W/T5) & 11 ft. flex 2-32-t8 (2 lamp/32W/T8) 2-28-t5 (2 lamp/28W/T5) sAT-Satellite fixture w/o ballast 1-54-t5ho (1 lamp/54W/T5HO) *must be ordered separately 2-54-t5hO (2 lamps/54W/T5HO) EX: 14-OfT-2-17-T8-MAS2 and 14-OfT-2-17-T8-SAT

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank)-Grid

series OFTOracle Flanged Troffer

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

(For other lamp type, please consult factory)

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

order code

Description

(Blank)

-

-

EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Advance Optanium

ADV-ESS

-

-

Advance Essential1

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101 1

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

Lutron Ecosystem H-Series1

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Rover

1

LUT-2W

-

-

Lutron Tu-Wire

EMG-SD-T8-BX-T5-T5HO-1400

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-EC3

LUT-EC3

LUT-EC3

Lutron Eco-10

OTHER options

LUT-TVE

-

-

Lutron Tve1

14ALDF - Aluminum Door frame C3 - 6’ 3-wire Flex Cable (Single Circuit)

LUT-H3D LUT-H3D -

-

1

1

LUT-H3D

Lutron Hi-Lume 3D1

LUT-ECD

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance GDF - Gasketed Door Frame

Special options are available

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

61

Fluorescent Recessed Flanged Specification Grade Troffer

14 - 1’ X 4’


T8/T5, 2’ X 4’ FLUORESCENT RECESSED FLANGED SPECIFICATION GRADE TROFFER

OfT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial applications. PRODUCT FEATURES: • Up to 80% efficiency. • Fixture is designed to install into drywall and plaster frame style ceilings. The flange is designed to fit into ceiling up to 1” thick. • Adjustable wing hangers securely engage onto wood or metal joists in the ceiling plenum. • Adjustable wing hanger for safely securing fixture housing to wood or metal joists. Available with optional yoke hangers. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Supplied with Advance or Universal ballast standard. • Clear 0.100” thick #12 pattern acrylic lens, standard. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

4-3/4" 24-3/4"

48"

2X4 OFT

Ordering Information Example: 24-Oft-3-32-t8-A12 24

OfT trim type

Fixture Size

Fluorescent Recessed Flanged Specification Grade Troffer

24 - 2’ X 4’

voltage3

# of ballast

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF 120 (Consult factory for LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type MAS2-Master fixture w/ 2 2-32-t8 (2 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) ballast & 11 ft. flex 3-32-t8 (3 lamps/32W/T8) 3-28-t5 (3 lamps/28W/T5) sAT-Satellite fixture w/o ballast 4-32-t8 (4 lamps/32W/T8) 4-28-t5 (4 lamps/28W/T5) *must be ordered separately 2-54-t5ho (2 lamps/54W/T5HO) EX: 24-OFT-3-32-T8-MAS2 3-54-t5ho (3 lamps/54W/T5HO) and 24-OFT-3-32-T8-SAT 4-54-t5ho (4 lamps/54W/T5HO)

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank)-Grid

series OFTOracle Flanged Troffer

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

(For other lamp type, please consult factory)

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

32w/T8

28w/T5

Description

order code

(Blank) EPS ADV-7 ADV-102

(Blank)1 -

(Blank) ADV-71 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

-

ADV-OPT

-

Advance Optanium3

EMG-T5-520

Up to 520 L. for T5

ADV-ESS2

-

-

Advance Essential3

Up to 700 L. for T5 or T5HO

ADV-ROVR

-

EMG-T5-T5HO-700

Up to 1300 L. for T5 or T5HO

LUT-EHD2

LUT-EHD1

LUT-EHD1

EMG-T5-T5HO-1300

-

-

Lutron Tu-Wire3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

LUT-2W1

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EC52 LUT-EC51

-

Lutron Ecosystem3

EMG-SD-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-EC32 LUT-EC31

LUT-EC31

EMG-ICE-T8-BX-T5-T5HO-1400

LUT-TVE1

54w/T5HO

ADV-ROVR2 Advance Rover3

-

-

LUT-H3D LUT-H3D 2

-

1

-

Lutron Ecosystem H-Series3

Lutron Eco-103

OTHER options

Lutron Tve3

LUT-H3D

Lutron Hi-Lume 3D

LUT-ECD1

Lutron Ecosystem (347V Only)3

1

3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

62

WWW.ORACLELIGHTING .COM

24ALDF - Aluminum Door frame C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance GDF - Gasketed Door Frame

Special options are available

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT RECESSED FLANGED SPECIFICATION GRADE TROFFER

OfT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial applications. PRODUCT FEATURES: • Up to 80% efficiency. • Fixture is designed to install into drywall and plaster frame style ceilings. The flange is designed to fit into ceiling up to 1” thick. • Adjustable wing hangers securely engage onto wood or metal joists in the ceiling plenum. • Adjustable wing hanger for safely securing fixture housing to wood or metal joists. Available with optional yoke hangers. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Supplied with Advance or Universal ballast standard. • Clear 0.100” thick #12 pattern acrylic lens, standard. • Housing and door frame interface provides a superior mechanical light seal and hinges down for easy lamp replacement. Ballast can be accessed from below the ceiling. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

4-3/4" 24-3/4"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

24"

2X2

Ordering Information Example: 22-Oft-3-17-t8-A12 22

OfT trim type

Fixture Size

voltage3

# of ballast

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts HBF- High BF (Consult factory for 120 LBF- Low BF 277 Slot T mounting option) 347 *master/satellite MAS1-Master fixture w/ 1 ballast & 11 ft. flex # lamps/lamp type series MAS2-Master fixture w/ 2 ballast 2-17-t8 (2 lamps/17W/T8) OFT-Oracle 2-14-t5 (2 lamps/14W/T5) & 11 ft. flex 3-17-t8 (3 lamps/17W/T8) Flanged 3-14-t5 (3 lamps/14W/T5) sAT-Satellite fixture w/o ballast 4-17-t8 (4 lamps/17W/T8) Troffer 4-14-t5 (4 lamps/14W/T5) *must be ordered separately 2-32-U6-T8 (2 lamps/32W/T8) 2-24-t5ho (2 lamps/24W/T5HO) EX: 22-OFT-3-17-T8-MAS2 and 2-31-U1.5-T8 (2 lamps/31W/T8) 3-24-t5ho (3 lamps/24W/T5HO) 22-OFT-3-17-T8-SAT 3-31-U1.5-T8 (3 lamps/31W/T8) 4-24-t5ho (4 lamps/24W/T5HO) 2-40-BX (2 lamps/40W/BX TT) 3-40-BX (3 lamps/40W/BX TT) (For other lamp type, please consult factory) 4-40-BX (4 lamps/40W/BX TT)

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank)-Grid

32W/31w/T8 14w/T5 (Blank) -

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE 17w/T8 (Blank)

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

24w/T5HO -

40w/BX (Blank)2

Description Electronic Instant Start

order code EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX Up to 520 L. for T5

EPS ADV-72 ADV-102

EPS ADV-7 ADV-10

(Blank)2 -

(Blank)1 ADV-102

EPS1 ADV-101

-

-

-

-

-

Advance Optanium3

EMG-T5-520

ADV-ESS2

ADV-ESS

-

-

-

Advance Essential3

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

ADV-ROVR1

ADV-ROVR

-

-

-

Advance Rover3

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

-

LUT-EHD

-

-

-

Lutron Ecosystem H-Series3

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

-

LUT-2W1

-

-

-

Lutron Tu-Wire3

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

LUT-EC51

LUT-EC5

LUT-EC51

LUT-EC51

LUT-EC52

Lutron Ecosystem3

EMG-SD-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

LUT-EC32

LUT-EC3

LUT-EC31

LUT-EC31

LUT-EC32

Lutron Eco-103

EMG-ICE-T8-BX-T5-T5HO-1400

-

LUT-TVE1

-

-

-

LUT-H3D

LUT-H3D

LUT-H3D

LUT-H3D

LUT-H3D

-

-

-

-

-

2

2

1

1

OTHER options

Lutron Tve3 2

Lutron Hi-Lume 3D

3

Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

22ALDF - Aluminum Door frame C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

SBF - Internal Slow-Blow Fuse RIS - Radio Interference Suppressor USA - Made in America Compliance GDF - Gasketed Door Frame

Special options are available

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

63

Fluorescent Recessed Flanged Specification Grade Troffer

22 - 2’ X 2’

OFT


64


T8/T5, 1’ X 4’ FLUORESCENT SURFACE MOUNT SPECIFICATION GRADE TROFFER

OSMT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial lighting applications. Fixture is designed to flush mount onto drywall/hardpan ceilings. PRODUCT FEATURES: • Up to 80% efficiency. • Fixture is cold welded to provide extra strength and durability during installation and downstream maintenance. Four keyway slots/ mounting holes on the back of the housing provides several mounting options. Doorframe is hinged for easy access to lamps and ballasts. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Clear 0.100” thick #12 pattern acrylic lens, standard. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Designed for seamless and hassle free surface mounted installations. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

4-1/4" 12"

48"

1X4

Ordering Information Example: 14-OSMT-1-32-t8-A12 14

OSMT

Fixture Size

# lamps/lamp type

series

voltage1

# of ballast

lampS installed

ballast factor

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast (1 lamp/28W/T5) 2 -2 Ballasts HBF- High BF 120 (2 lamps/28W/T5) LBF- Low BF 277 (1 lamp/54W/T5HO) 347 *master/satellite (2 lamps/54W/T5HO) MAS1-Master fixture w/ 1 ballast & 11 ft. flex (For other lamp type, please consult factory) MAS2-Master fixture w/ 2 ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 14-OSMT-2-32-T8-MAS2 and 14-OSMT-2-32-T8-SAT

oSMt-Oracle 1-32-t8 (1 lamp/32W/T8) Surface 2-32-t8 (2 lamps/32W/T8) Mount Troffer

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

1-28-t5 2-28-t5 1-54-t5ho 2-54-t5hO

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

32w/T8

Description

order code

Electronic Instant Start

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5

28w/T5

54w/T5HO

(Blank)

-

-

EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Advance Optanium1

ADV-ESS

-

-

Advance Essential1

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

LUT-2W

-

-

Lutron Tu-Wire1

LUT-EC5

LUT-EC5

-

Lutron Ecosystem

LUT-EC3

LUT-EC3

LUT-EC3

LUT-TVE

-

LUT-H3D LUT-H3D -

-

-

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Eco-101

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Lutron Tve1

OTHER options

Advance Rover1 Lutron Ecosystem H-Series

1

1

LUT-H3D

Lutron Hi-Lume 3D1

LUT-ECD

Lutron Ecosystem (347V Only)1

1- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

GDF - Gasketed Door Frame C3 - 6’ 3-wire Flex Cable (Single Circuit)

SBF - Internal Slow-Blow Fuse

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

USA - Made in America Compliance

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

RIS - Radio Interference Suppressor Special options are available

65

Fluorescent Surface Mount Specification Grade Troffer

14 - 1’ X 4’

OSMT


OSMT

T8/T5, 2’ X 4’ FLUORESCENT SURFACE MOUNT SPECIFICATION GRADE TROFFER S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial lighting applications. Fixture is designed to flush mount onto drywall/hardpan ceilings. PRODUCT FEATURES: • Up to 80% efficiency. • Fixture is cold welded to provide extra strength and durability during installation and downstream maintenance. Four keyway slots/ mounting holes on the back of the housing provides several mounting options. Doorframe is hinged for easy access to lamps and ballasts. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Clear 0.100” thick #12 pattern acrylic lens, standard. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Designed for seamless and hassle free surface mounted installations. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

4-1/4" 24"

48"

2X4 OSMT

Ordering Information Example: 24-OSMT-3-32-t8-A12 24 Fixture Size

Fluorescent Surface Mount Specification Grade Troffer

24 - 2’ X 4’

OSMT series

# lamps/lamp type

oSMt-Oracle 2-32-t8 (2 lamps/32W/T8) Surface 3-32-t8 (3 lamps/32W/T8) Mount 4-32-t8 (4 lamps/32W/T8) Troffer

voltage3

lampS installed

ballast factor

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

32w/T8

28w/T5

Description

order code

(Blank) EPS ADV-7 ADV-102

(Blank)1 -

(Blank) ADV-71 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

-

ADV-OPT

-

Advance Optanium3

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

ADV-ESS2

-

-

Advance Essential3

EMG-T5-520

Up to 520 L. for T5

ADV-ROVR

-

LUT-EHD

LUT-EHD

LUT-EHD

LUT-2W1

-

-

Lutron Tu-Wire3

LUT-EC5

LUT-EC5

-

Lutron Ecosystem

2

2

54w/T5HO

LUT-TVE

1

1

-

LUT-H3D2 LUT-H3D1 -

-

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Eco-103

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Lutron Tve

OTHER options

ADV-ROVR2 Advance Rover3 1

LUT-EC32 LUT-EC31

1

LUT-EC31 -

Lutron Ecosystem H-Series

3

3

3

LUT-H3D1

Lutron Hi-Lume 3D3

LUT-ECD1

Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

66

# of ballast

(Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast (2 lamps/28W/T5) 2 -2 Ballasts HBF- High BF 120 (3 lamps/28W/T5) LBF- Low BF 277 (4 lamps/28W/T5) 347 *master/satellite (2 lamps/54W/T5HO) (3 lamps/54W/T5HO) MAS1-Master fixture w/ 1 (4 lamps/54W/T5HO) ballast & 11 ft. flex MAS2-Master fixture w/ 2 (For other lamp type, please consult factory) ballast & 11 ft. flex sAT-Satellite fixture w/o ballast *must be ordered separately EX: 24-OSMT-3-32-T8-MAS2 and 24-OSMT-3-32-T8-SAT 2-28-t5 3-28-t5 4-28-t5 2-54-t5ho 3-54-t5ho 4-54-t5ho

WWW.ORACLELIGHTING .COM

GDF - Gasketed Door Frame C3 - 6’ 3-wire Flex Cable (Single Circuit)

SBF - Internal Slow-Blow Fuse

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

USA - Made in America Compliance

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

RIS - Radio Interference Suppressor Special options are available

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2’ X 2’ FLUORESCENT SURFACE MOUNT SPECIFICATION GRADE TROFFER

OSMT

S H I P P I N G AVA I L A B L E

APPLICATION: General illumination for most commercial lighting applications. Fixture is designed to flush mount onto drywall/hardpan ceilings. PRODUCT FEATURES: • Up to 80% efficiency. • Fixture is cold welded to provide extra strength and durability during installation and downstream maintenance. Four keyway slots/ mounting holes on the back of the housing provides several mounting options. Doorframe is hinged for easy access to lamps and ballasts. • Mitered door frame prevents light leaks, and minimizes dust from entering fixture. • Door frame is designed with cam latches and T hinges to secure frame to housing and allows for easy lamp maintenance. • Gasketed door frame prevents light leakage. • Clear 0.100” thick #12 pattern acrylic lens, standard. •  Post Painted high gloss white powder coat finish maximizes distribution and efficiency while providing visual comfort. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Designed for seamless and hassle free surface mounted installations. • Same day shipping on most options. Consult Factory. • Supplied standard with Philips Advance, GE or Universal ballast. • Wide Variety of dimming and daylight harvesting options available. • NEC required ballast disconnect is standard.

4-1/4" 24"

LISTING - UL/ C-UL listed to US and Canadian Standards. WARRANTY - Guaranteed for one year against mechanical defects.

24"

2X2

Ordering Information Example: 22-OSMT-3-17-t8-A12 22

OSMT

OSMT series

22 - 2’ X 2’

oSMt2-17-t8 Oracle 3-17-t8 Surface 4-17-t8 Mount 2-32-U6-T8 Troffer 2-31-U1.5-T8 3-31-U1.5-T8

# lamps/lamp type

voltage3

# of ballast

BALLAST CONFIGURATION & CODE 17w/T8 (Blank) EPS ADV-72 ADV-102

32W/31w/T8 14w/T5 (Blank) EPS (Blank)2 ADV-7 ADV-10 -

40w/BX (Blank)2 EPS1 ADV-101

Description Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

order code

-

-

-

-

Advance Optanium

ADV-ESS2

ADV-ESS

-

-

-

Advance Essential3

ADV-ROVR1

ADV-ROVR

-

-

-

Advance Rover3

-

LUT-EHD

-

-

-

Lutron Ecosystem H-Series

-

LUT-2W1

-

-

-

Lutron Tu-Wire3

1

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC5

LUT-EC32

LUT-EC3

LUT-EC31

LUT-EC31

LUT-EC32

1

3

diffuser type A12 A125 A19 A15 ASW PCL1 PCL2 PCL3 PCL4

#12 pattern acrylic .10” thick #12 pattern acrylic .125” thick #19 pattern acrylic .156” thick’ #15 pattern acrylic .20” thick Acrylic smooth .080” thick 5/8”X5/8”X3/8”plastic louvers 1-1/2”X1-1/2”X1” plastic louver 3/4”X3/4”X1/2” plastic louver 3”X3”X1-1/2” plastic louver

2

-

LUT-TVE

-

-

-

LUT-H3D2

LUT-H3D1

LUT-H3D1

LUT-H3D2

-

-

-

-

-

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-520

Up to 520 L. for T5 Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Lutron Ecosystem

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Lutron Eco-103

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Lutron Tve

OTHER options

3

3

Lutron Hi-Lume 3D3 Lutron Ecosystem (347V Only)3

1- Requires 2 Ballasts for 3 or 4 lamps. 2- Requires 2 Ballasts for 4 lamps. 3- Voltage must be specified for dimming ballast.

WWW. ORACLELIGHTING . COM

EMG-T8-BX-450

EMG-T5-T5HO-700 3

LUT-H3D2

1

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

emergency battery pack options (L. = Lumens)

24w/T5HO (Blank)1 ADV-102

-

1

lampS installed

ballast factor

2-14-t5 (2 lamps/14W/T5) (2 lamps/17W/T8) (Blank)- Normal BF (Blank) - MVOLT (120/277) (Blank) -1 Ballast 3-14-t5 (3 lamps/14W/T5) (3 lamps/17W/T8) 2 -2 Ballasts HBF- High BF 120 4-14-t5 (4 lamps/14W/T5) (4 lamps/17W/T8) LBF- Low BF 277 (2 lamps/32W/T8) 2-24-t5ho (2 lamps/24W/T5HO) 347 *master/satellite (2 lamps/31W/T8) 3-24-t5ho (3 lamps/24W/T5HO) MAS1-Master fixture w/ 1 (3 lamps/31W/T8) 4-24-t5ho (4 lamps/24W/T5HO) ballast & 11 ft. flex 2-40-BX (2 lamps/40W/BX TT) MAS2-Master fixture w/ 2 3-40-BX (3 lamps/40W/BX TT) ballast & 11 ft. flex (For other lamp type, please consult factory) 4-40-BX (4 lamps/40W/BX TT) sAT-Satellite fixture w/o ballast *must be ordered separately EX: 22-OSMT-3-17-T8-MAS2 and 22-OSMT-3-17-T8-SAT

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

GDF - Gasketed Door Frame C3 - 6’ 3-wire Flex Cable (Single Circuit)

SBF - Internal Slow-Blow Fuse

C4 - 6’ 4-wire Flex Cable (Double Circuit) FBF - Internal Fast Blow Fuse

USA - Made in America Compliance

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

RIS - Radio Interference Suppressor Special options are available

67

Fluorescent Surface Mount Specification Grade Troffer

Fixture Size


High Bay Series

UP TO

93%

EFFICIENCY

LET THERE BE LIGHT Oracle Lighting is proud to introduce the Cool Beam Series: a new breed of specification grade Fluorescent High Bays complete with mounting, dimming and shielding options, for every application. Compared to traditional 400W MH fixtures, our Cool Beam High Bays deliver more usable lumens, require no warm up time, have excellent efficiency in the mid 90’s, and provide greater energy savings. On the next job, make sure you ask about our new Cool Beam

!

Fluorescent High Bay and LET THERE BE LIGHT

Energy Saving ELITE Lighting Fluorescent high bay has designed to offer significant energy saving opportunities over HID light systems.

400 300 200 100

Energy Consumption in WATT

500

455

WATT

346

WATT

221

WATT

HID 400 WATT 6 Lamp 54 T5HO Fluorescent

68

6 Lamp 32 T8 Fluorescent

229

WATT

4 Lamp 54 T5HO Fluorescent


COOL BEAM HIGH BAY [capabilities] ability [ abil·i·ty ]

the quality of being able to perform; a quality that permits or facilitates achievement or accomplishment. 4. CREDITABILITY Cool Beam fixtures use only well known components in the industry such as High Temperature Advance ballast , Leviton sockets, IOTA and 3. DURABILITY Bodine Emergency battery Post painted high gloss enamel packs. finish ensures maximum adhesion and rust resistance. 2. ACCESSIBILITY Full size access plate is located on the top of the full body for quick wiring and maintenance.

1. RELIABILITY Slot louvers on each side ensure that the ballast will remain cool and operate for its rated lifetime.

5. CONNECTABILITY NEC required ballast disconnects along with quick disconnects are standard.

5 4 10

3

* CONTROLLABILITY Leviton’s fixture mounted sensor provide fast, easy installation and instant energy saving. (Optional Item)

9

2 1

8

7 6

6. MANAGEABILITY All sides and corner are turned in removing sharp edges for safe handling and installation.

7. FLEXIBILITY Rotary sockets provide great lamp retention and conceal contacts.

8. REFLECTIVITY Highly tooled 95% reflective premium reflector material is engineered to optimize the thermal and luminous environment.

9. SERVICEABILITY Reflector, wireguard clear lens with door frame hinges down by removing two screws and allows for quick maintenance and access to ballast without removing lamps.

10. SUPPORTABILITY Four corner tie points are standard for safety wire support when required.

69


FLUORESCENT HIGH BAY SUPPORTABILITY GSS

GSS - Gripple Suspension System is fully adjustable for different mounting heights. “Y” style comes standard with 10’ length. Other lengths are available upon request.

GSSP

VH

GSSP - Paddles and tool-less, adjustable looping cable grippers. “Y” style comes standard 10’ length. Other lengths are available upon request.

VHCH

VH - Easy to install V Hooks snap into predrill holes at the top of high bay body and ensure strong support.

VHCH - Easy to install V-Hook and Chain Kit includes all necessary mounting accessories. Kit includes 2 V-Hooks, 2 chains (32”), 2 S-Hooks for adjustment, and 2 “S” hooks for connecting chain to V-Hooks.

FLUORESCENT HIGH BAY OTHER OPTIONS PLDF

CLDF

PLDF - Acrylic #12 pattern lens attached is fitted into door frame. Other prismatic lens options available upon request.

WG

CLDF - Clear Lens comes with door frame and easily swings open for easy lamp replacement.

WGDF

WG - Post pointed wireguard protects lamps from objects that may impact fixture. Ideal for gymnasiums and sports facilities. Wireguard is held by 4 clips that attach to fixture.

70

WGCL/ WGPL

MH

WGDF - Post pointed flat Wireguard with door frame. Protects lamps from being impacted by objects.

WWW.ORACLELIGHTING .COM

WGCL - Post pointed wireguard with clear lens and door frame. WGPL - Post pointed wireguard with prismatic Acrylic #12 pattern lens and door frame

MH - Mounting Hub is made from Cast-iron and allows for pendant mounting and acts as junction box. Top Plate slides for balancing and access to wiring. Multiple Knockouts on sides are standard.

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


PART# : MS- Motion Sensor MS - Motion Sensor works in 8’ to 40’ mounting heights. It offers an adjustable time setting of 30 sec. to 30 minutes and comes with three optic lenses ( 360º High Bay, 360º Low Bay, and Aisle ). Motion sensor comes prewired and ready for simple snap-n-go installation.

9.1m (30 ft)

High Bay 360˚ Top View

6.1m (20 ft) 3m (10 ft) 0 3m (10 ft) 6.1m (20 ft) 9.1m (30 ft) 0

Side View

6.1m (20 ft) 9.1m (30 ft) 12.2m (40 ft) 3m 9.1m 6.1m (30 ft) (20 ft) (10 ft)

0

3m 6.1m 9.1m (10 ft) (20 ft) (30 ft)

9.1m (30 ft)

Aisle Top View

6.1m (20 ft) 3m (10 ft) 0

Motion Sensor FEATURES

3m (10 ft) 6.1m (20 ft) 9.1m (30 ft)

Quicksnap: built into the 1/2” nipple, this locking mechanism allows for the fastest and easiest mounting not requiring a threaded lock-nut

0

Side View

6.1m (20 ft) 9.1m (30 ft)

S H E L V E S

S H E L V E S

12.2m (40 ft)

Fast, easy time delay setting: can be set at any time without requiring power to the sensor; time delay is variable from 30s-20m High Inrush Stability (H.I.S. Technology): :: Zero crossing circuitry optimizes relay operation for reliable, long-life operation :: Robust mechanical latching relay is durable for all load types Auto temperature calibration: automatically adjusts the PIR sensitivity as ambient temperature rises to increase detection of heat movement through the field-of-view Return to last state: for safety and energy savings, the MS contains a latching relay so that in the event power is lost to the device, the device will return to the last known state of the relay False detection intelligence: for increased energy savings and to mitigate nuisance tripping, the super bright LED indicates advanced detection has been activated and the lights will only turn

3m 9.1m 6.1m (30 ft) (20 ft) (10 ft)

0

3m 6.1m 9.1m (10 ft) (20 ft) (30 ft)

9.1m 6.1m 3.0m (30 ft) (20 ft) (10 ft)

0

3.0m 6.1m 9.1m (10 ft) (20 ft) (30 ft)

9.1m (30 ft)

Low Bay 360˚ Top View

6.1m (20 ft) 3.0m (10 ft) 0 3.0m (10 ft) 6.1m (20 ft) 9.1m (30 ft) 0

Side View

2.4m (8 ft) 6.1m (20 ft) 7.6m (25 ft)

FLUORESCENT HIGH BAY CONNECTABILITY

PCSB Straight blade plug is available in: • 120V NEMA 5-15R • 277V NEMA 7-15R

PCTL Twist lock plug is available in: • 120V NEMA L5-15R • 277V NEMA L7-15R

C3/C4 C3 wire flex cable is single circuit and C4 wire flex cable is double circuit.

SO Cord - available in: • 120V/277V • 480V

* 10’ STANDARD LENGTH - AVAILABLE IN CUSTOM LENGTHS WWW. ORACLELIGHTING .COM

• TEL : 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

71 71


BLENDING MOTION SENSOR WITH PHOTOCELL TECHNOLOGY PART# : MSPH Photocell option- For daylight Harvesting. :: Integrated rotating adjustable light sensor for light hold-off. :: 24 hour auto-calibration. :: Quick snap feature for easy installation. :: T5 fixture with Leviton’s new MSPH sensor with built-in photocell uses 85% less energy than a 400W HID fixture. :: Meets DOE & TITLE 24 requirements. :: Photocell has variable sensitivity control.

85%

:: Adjustable time delay (No Power Required).

less energy than an HID fixture 500

PHOTOCELL FEATURES

450

•Standard T-5 Highbay fixture uses 48% less 400

energy than a standard 400W HID fixture

350

•T-5 fixture with standard Leviton MSPH

300

HID

Sensor uses 60% less energy than an

T-5 W/O Sensor

250

HID fixture

T-5 W/ OSFHU T-5 W/ OSFHP

200

less energy

than an HID fixture •T-5 fixture with Leviton’s new MSPH sensor

WATTAGE

85%

150 100 50 0

with built in Photocell uses 85% less energy than an HID fixture

TYPICAL WORK HOUR

120-347V and 480V Models

Low Voltage 24V Models (-ILW)

120-230-277-347VAC; 240/480VAC (-I4W models)

24VAC/VDC

ELECTRICAL Input Voltage Minimum Load Output Channels Time Delay Wire Designation ENVIRONMENTAL Operating Temperature Range Cold Storage Temperature Range Relative Humidity OTHER Agency Listings Warranty 72

No Requirement Latching Relay

HVAC Form C N/O, N/C Load 1: 30s - 30m

Line-Black, Load-Red, Neutral-White

Line-Black, Load-Red, Neutral-White; OCC=Blue, PH=Gray, HVAC=Brown

14° F to 160° F (-10° C to 71° C) -40° F to 160° F (-40° C to 71° C) 0% to 90% non-condensing UL 916, CSA 22.2 No. 205 M1983, FCC Certified, Title 24 Compliant Limited 5-Year


BLENDING MOTION SENSOR WITH PHOTOCELL TECHNOLOGY

MSPH

Motion Sensor with Photocell

1-1/2”

4-1/2”

4-1/2”

120-347V and 480V Models

Low Voltage 24V Models (-ILW)

120-230-277-347VAC; 240/480VAC (-I4W models)

24VAC/VDC

ELECTRICAL Input Voltage Operational Frequencies

Load Rating

Minimum Load Output Channels Time Delay Wire DesignationL ENVIRONMENTAL Operating Temperature Range Cold Storage Temperature Range Relative Humidity OTHER Agency Listings Warranty

50/60Hz Fluorescent Ballasts: 800VA @ 120VAC Ballast 1000VA @ 230VAC Ballast 1200VA @ 277VAC Ballast 1500VA @ 347VAC Ballast 2000VA @ 480VAC Ballast Motor: 1/4 HP Load @ 120V Compatible with electronic and magnetic ballasts, electronic and magnetic low-voltage transformers. No Requirement Latching Relay Load 1: 30s - 30m ine-Black, Load-Red, Neutral-White

Input: 20mA Output: 120mA HVAC: 1A, 30VDC

HVAC Form C N/O, N/C

Line-Black, Load-Red, Neutral-White; OCC=Blue, PH=Gray, HVAC=Brown

14° F to 160° F (-10° C to 71° C) -40° F to 160° F (-40° C to 71° C) 0% to 90% non-condensing UL 916, CSA 22.2 No. 205 M1983, FCC Certified, Title 24 Compliant Limited 5-Year 73


4 lamp, t5 fluorescent high bay photometrics CB-4-54-t5ho lamp: PHILIPS F54T5/841/HO/ALTO 180

150

120

90

1863 60 5588

Lamp lumens: 4450

Zonal lumens summary zone lumens 0-30 5909.6 4,781.50 0-40 9307.6 7,527.80 0-60 17842.31 13,010.40 60-90 20439.92 3,533.00 o-90 20439.92 16,543.40

total luminaire efficiency: 92.8% spacing criteria: 1.10 candela tabulation

%lamp 24.3 26.90% 38.3 42.30% 65.2 73.10% 84.1 19.80% 84.1 92.90%

%fixt 28.9 28.90% 45.5 45.50% 77.5 78.60% 100 21.40% 100 100%

total luminiare efficiency = 92.8%

t5 fluorescent high bay

7450

0

efficiency = 92.8%

30

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0 8687.6 7441.95 8652.8 7429.67 8388 7136.77 7793.2 6510.57 6796.9 5577.7 4549.65 5511.9 3404.83 4159.7 2109.03 2663.8 905.43 1201.2 101.61 143.2 0 0

22.5

45

67.5

8687.6 7441.95 8669.6 7402.69 8372.6 6952.61 7461.9 5953.38 5722.7 4356.65 3099.66 4003.1 2436.6 3098.7 1851.73 2214.8 903.25 1122.6 336.18 476.9 0

8687.6 7441.95 8685.2 7360.66 7876.4 6338.93 5791.3 4544.72 4888.1 3801.86 3660.18 4302.6 3117.57 3588.9 1750.01 2176.8 1231.39 1613.7 368.9 617.3 0

8687.6 7441.95 8669 7302.45 7121.7 5591.37 5408.2 4264.45 5114 4367.9 4123.57 4658.1 2917.22 3338.1 1731.87 2258.3 1585.59 2093.2 300.13 584.4 0

0

0

0

90 8687.6 7441.95 8619.5 7253.89 6815.9 5308.35 5435.4 4291.55 5138.1 4487.54 4162.15 4621.1 2718.01 3183 1862.64 2419.7 1638.18 2207.6 258.45 533.1 0 0

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 112 111 100 100 98 111 111 100 111 108 98 108 98 108 101 96 92 8089 98 85 94 8291 1 91 87 83 89 92 84 70 78 6572 89 74 82 6976 2 83 76 80 84 74 60 66 5460 81 65 72 5965 3 76 67 73 77 66 52 58 4651 75 58 64 5157 4 69 59 67 71 59 45 51 4044 69 52 58 4550 5 64 53 62 65 53 40 45 3539 64 47 52 4044 6 59 48 57 61 48 36 40 3135 59 43 48 3640 7 55 44 53 57 44 33 36 2831 55 39 44 3236 8 51 40 50 53 41 30 33 2528 52 36 40 3033 9 48 37 47 50 38 27 30 2326 49 33 37 2730 10 45 34 44 RC - Ceiling Cavity Reflectance RW - Wall Reflectance

50% 50% 30% 10% 93 103 93 103 93 103 90 79 87 76 84 81 79 66 74 63 70 71 70 57 64 53 59 63 62 50 55 45 50 56 56 44 49 39 44 50 51 39 44 34 38 46 46 35 39 31 34 42 42 32 36 28 31 38 39 29 32 25 28 35 36 27 30 23 25 33

10% 98 108 7887 6471 5460 4651 4044 3539 3134 2831 2528 2325

30% 50% 30% 10% 89 89 99 89 99 99 87 76 84 74 82 78 76 64 72 61 68 68 67 56 62 52 58 60 60 49 54 44 50 54 54 43 48 39 43 49 49 38 43 34 38 44 45 35 39 30 34 40 41 31 35 27 30 37 38 29 32 25 28 34 35 26 29 23 25 32

50% 86 95 83 75 73 66 65 58 58 52 52 47 48 43 44 39 40 36 37 33 35 31

10% 30% 10% 86 86 95 95 81 71 79 73 70 60 67 63 60 51 57 54 53 44 49 48 47 38 43 42 42 34 38 38 38 30 34 34 34 27 30 31 32 25 27 28 29 23 25 26

0% 0% 84 93 77 70 65 58 55 49 47 42 41 36 36 32 32 29 29 26 26 23 24 21

6lamp, t5 fluorescent high bay photometrics CB-6-54-t5ho lamp: PHILIPS F54T5/841/HO/ALTO 180

150

120

90

2668 60 8005

Zonal lumens summary zone lumens 0-30 5909.6 7,240.20 0-40 9307.6 11,405.00 0-60 17842.31 19,414.50 60-90 20439.92 5,635.80 o-90 20439.92 25,050.30

total luminaire efficiency: 93.8% spacing criteria: 1.16 candela tabulation

%lamp 24.3 27.10% 38.3 42.70% 65.2 72.70% 84.1 21.10% 84.1 93.80%

%fixt 28.9 28.90% 45.5 45.50% 77.5 77.50% 100 22.50% 100 100%

total luminiare efficiency = 93.8%

t5 fluorescent high bay

10673

0

Lamp lumens: 4450

30

efficiency = 93.8%

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0

22.5

45

67.5

8687.6 10651 8652.8 10608 8388 10284 7793.2 9554 6796.9 8333 6758 5511.9 5100 4159.7 3266 2663.8 1473 1201.2 176143.2 0

8687.6 10651 8669.6 10629 8372.6 10265 7461.9 9148 5722.7 7016 4908 4003.1 3799 3098.7 2715 2214.8 1376 1122.6 585476.9 0

8687.6 10651 8685.2 10648 7876.4 9656 5791.3 7100 4888.1 5993 5275 4302.6 4400 3588.9 2669 2176.8 1978 1613.7 757 617.3 0

8687.6 10651 8669 10628 7121.7 8731 5408.2 6630 5114 6270 5711 4658.1 4093 3338.1 2769 2258.3 2566 2093.2 716584.4 0

0

0

0

0

90 8687.6 10651 8619.5 10568 6815.9 8356 5435.4 6664 5138.1 6299 5665 4621.1 3902 3183 2967 2419.7 2707 2207.6 654 533.1 0 0

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 112 112 100 100 98 112 112 100 112 109 98 109 98 109 102 97 93 8089 99 85 95 8291 1 91 87 83 89 92 84 70 78 6572 90 74 83 6977 2 83 76 80 84 74 60 66 5460 82 65 73 5966 3 76 67 73 77 66 52 58 4651 75 58 65 5157 4 69 59 67 71 59 45 51 4044 69 52 58 4550 5 64 53 62 66 53 40 45 3539 64 47 52 4045 6 59 48 57 61 49 36 40 3135 60 43 48 3640 7 55 44 53 57 44 33 36 2831 56 39 44 3236 8 51 40 50 53 41 33 28 52 9 48 37 30 25 47 3640 3033 50 38 27 30 2326 49 33 37 2730 10 45 34 44 RC - Ceiling Cavity Reflectance RW - Wall Reflectance 74

10% 98 94 7878 6466 5456 4649 4042 3538 3134 2830 2527 2325

50% 50% 30% 10% 93 104 93 104 93 104 91 79 88 76 85 81 79 66 74 63 70 71 70 57 64 53 59 63 62 50 56 45 50 56 56 44 49 39 44 50 51 39 44 34 38 46 46 35 39 31 34 42 43 32 36 28 31 38 39 33 28 35 29 25 36 27 30 23 25 33

WWW.ORACLELIGHTING .COM

30% 50% 30% 10% 89 100 89 100 89 100 87 76 84 74 82 78 76 64 72 61 68 68 67 56 62 52 58 60 60 49 54 44 50 54 54 43 48 39 43 49 49 38 43 34 38 44 45 35 39 30 34 40 41 31 35 27 31 37 38 32 28 34 29 25 36 26 30 23 25 32

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

50% 86 96 84 75 73 66 65 58 58 52 52 47 48 43 44 39 40 36 37 33 35 31

10% 30% 10% 86 86 96 96 82 71 80 73 70 60 67 63 60 51 57 54 53 44 49 48 47 38 43 42 42 34 38 38 38 30 34 34 35 27 30 31 32 28 28 25 29 23 25 26

• FA X : 1 - 8 7 7 - 3 7 5 - 3333

0% 0% 84 94 78 70 65 58 55 49 47 42 41 36 36 32 32 29 29 26 26 23 24 21


4 lamp, t8 fluorescent high bay photometrics CB-4-32-t8 lamp: PHILIPS F32t8/tl24/plus/ALTO 180

150

120

90

1215 60 3646

Lamp lumens: 2950

Zonal lumens summary zone lumens 0-30 5909.6 3122.26 0-40 9307.6 4914.42 0-60 17842.31 8492.39 60-90 20439.92 2305.00 o-90 20439.92 10797.87

total luminaire efficiency: 91.5% spacing criteria: 1.10 candela tabulation

%lamp 24.3 26.5 38.3 41.6 65.2 72 84.1 19.5 84.1 91.5

%fixt 28.9 28.9 45.5 45.5 77.5 78.6 100 21.4 100 100

total luminiare efficiency = 91.5%

t8 fluorescent high bay

4861

0

efficiency = 91.5%

30

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0

22.5

6328.05 4855.44 6302.7 4847.43 6109.82 4656.32 5676.57 4247.77 4950.86 3639.13 2968.39 4014.87 2221.46 3029.93 1376.02 1940.31 590.74 874.95 66.3 104.31 0

6328.05 4855.44 6314.94 4829.82 6098.6 4536.17 5435.25 3884.23 4168.41 2842.46 2022.35 2915.86 1589.74 2257.09 1208.15 1613.26 589.32 817.7 219.33 347.37 0

0

0

45

67.5

6328.05 4855.44 6326.3 4802.4 5737.17 4135.78 4218.38 2965.17 3560.49 2480.5 2388.05 3134.01 2034.03 2614.15 1141.77 1585.58 803.41 1175.42 240.69 449.64 0 0

6328.05 4855.44 6314.5 4764.42 5187.45 3648.04 3939.33 2782.31 3725.04 2849.8 2690.39 3392.96 1903.32 2431.47 1129.94 1644.95 1034.5 1524.69 195.82 425.68 0 0

90 6328.05 4855.44 6278.44 4732.73 4964.7 3463.38 3959.15 2799.98 3742.59 2927.85 2715.56 3366.01 1773.34 2318.5 1215.27 1762.51 1068.81 1608.02 168.62 388.31 0 0

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 100 109 100 109 100 100 98 109 109 106 98 106 98 106 1 91 87 83 89 99 95 91 80 87 97 85 93 8289 90 83 70 76 65 71 88 74 81 6975 2 83 76 80 82 73 60 65 54 59 80 65 71 5964 3 76 67 73 76 65 52 57 46 50 74 58 63 5156 4 69 59 67 70 58 45 50 40 44 68 52 57 4549 5 64 53 62 64 52 40 44 35 38 63 47 51 4044 6 59 48 57 60 48 36 40 31 34 58 43 47 3639 7 55 44 53 56 44 33 36 28 30 54 39 43 3236 8 51 40 50 52 40 30 33 25 28 51 36 40 3032 9 48 37 47 49 37 27 30 23 25 48 33 37 2730 10 45 34 44 RC - Ceiling Cavity Reflectance RW - Wall Reflectance

50% 50% 30% 10% 93 93 102 93 102 102 81 89 79 86 76 83 78 66 73 63 69 71 69 57 63 53 58 63 61 50 55 45 49 56 55 44 48 39 43 50 50 39 43 34 38 46 45 35 39 31 34 42 42 32 35 28 30 38 38 29 32 25 27 35 36 27 29 23 25 33

10% 98 106 7886 6470 5459 4650 4043 3538 3134 2830 2527 2325

30% 50% 30% 10% 89 89 89 97 97 97 78 85 76 83 74 81 75 64 71 61 67 68 66 56 61 52 57 60 59 49 53 44 49 54 53 43 47 39 42 49 48 38 42 34 37 44 44 35 38 30 33 40 41 31 34 27 30 37 37 29 32 25 27 34 35 26 29 23 25 32

50% 86 93 75 82 72 66 64 58 57 52 51 47 47 43 43 39 39 36 37 33 34 31

10% 30% 10% 86 86 93 93 73 80 71 78 69 60 66 63 59 51 56 54 52 44 48 48 46 38 42 42 41 34 37 38 37 30 33 34 34 27 30 31 31 25 27 28 29 23 25 26

0% 0% 84 92 70 76 64 58 54 49 46 42 40 36 35 32 31 29 28 26 25 23 23 21

6 lamp, t8 fluorescent high bay photometrics CB-6-32-t8 lamp: PHILIPS F32t8/tl24/plus/ALTO 180

150

120

90

1585 60 4756

Zonal lumens summary zone lumens 0-30 5909.6 4,731.80 0-40 9307.6 7,453.60 0-60 17842.31 12,688.20 60-90 20439.92 3,683.20 o-90 20439.92 16,371.40

total luminaire efficiency: 92.5% spacing criteria: 1.16 candela tabulation

%lamp 24.3 26.70% 38.3 42.10% 65.2 71.70% 84.1 20.80% 84.1 92.50%

%fixt 28.9 28.90% 45.5 45.50% 77.5 77.50% 100 22.50% 100 100%

total luminiare efficiency = 92.5%

t8 fluorescent high bay

6341

0

Lamp lumens: 2950

30

efficiency = 92.5%

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0 6328.05 6961 6302.7 6933 6109.82 6721 5676.57 6244 4950.86 5446 4416 4014.87 3333 3029.93 2134 1940.31 962874.95 115104.31 0 0

22.5 6328.05 6961 6314.94 6946 6098.6 6708 5435.25 5979 4168.41 4585 3207 2915.86 2483 2257.09 1775 1613.26 899817.7 382347.37 0 0

45

67.5

6328.05 6961 6326.3 6959 5737.17 6311 4218.38 4640 3560.49 3917 3447 3134.01 2876 2614.15 1744 1585.58 1293 1175.42 495 449.64 0 0

6328.05 6961 6314.5 6946 5187.45 5706 3939.33 4333 3725.04 4098 3732 3392.96 2675 2431.47 1809 1644.95 1677 1524.69 468425.68 0 0

90 6328.05 6961 6278.44 6906 4964.7 5461 3959.15 4355 3742.59 4117 3703 3366.01 2550 2318.5 1939 1762.51 1769 1608.02 427 388.31 0 0

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 100 110 100 110 100 100 98 110 110 108 98 108 98 108 1 91 87 83 89 100 96 91 80 88 98 85 93 8290 91 83 70 77 65 71 89 74 81 6976 2 83 76 80 83 73 60 66 54 59 81 65 72 5965 3 76 67 73 76 65 52 57 46 51 74 58 64 5156 4 69 59 67 70 58 45 50 40 44 68 52 57 4549 5 64 53 62 65 53 40 44 35 38 63 47 52 4044 6 59 48 57 60 48 36 40 31 34 59 43 47 3639 7 55 44 53 56 44 33 36 28 31 55 39 43 3236 8 51 40 50 53 40 33 28 51 40 3033 9 48 37 30 25 47 36 49 37 27 30 23 25 48 33 37 2730 10 45 34 44 RC - Ceiling Cavity Reflectance RW - Wall Reflectance WWW. ORACLELIGHTING . COM

10% 98 92 7877 6465 5455 4648 4042 3537 3133 2830 2527 2325

50% 50% 30% 10% 93 93 103 93 103 103 81 89 79 86 76 84 78 66 73 63 69 71 69 57 63 53 58 63 61 50 55 45 49 56 55 44 48 39 43 50 50 39 43 34 38 46 46 35 39 31 34 42 42 32 35 28 30 38 39 32 27 35 29 25 36 27 29 23 25 33

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

30% 50% 30% 10% 89 89 89 98 98 98 78 86 76 83 74 81 75 64 71 61 67 68 66 56 61 52 57 60 59 49 53 44 49 54 53 43 47 39 43 49 48 38 42 34 38 44 44 35 38 30 33 40 41 31 35 27 30 37 38 32 27 34 29 25 35 26 29 23 25 32

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

50% 86 94 75 82 72 66 64 58 57 52 52 47 47 43 43 39 40 36 37 33 34 31

10% 30% 10% 86 86 94 94 73 80 71 79 69 60 66 63 60 51 56 54 52 44 48 48 46 38 42 42 42 34 37 38 37 30 33 34 34 27 30 31 31 27 28 25 29 23 25 26

0% 0% 84 92 70 77 64 58 54 49 46 42 40 36 35 32 31 29 28 26 25 23 23 21

75


CB4

T5 COOL BEAM FLUORESCENT HIGH BAY (4 LAMP FULL BODY SPECIFICATION GRADE)

CB

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. 5YR WARRANTY 5YR WARRANTY • Using the latest optical technology our 4 lamp CB luminaire out A M B I E Nperforms T MH fixtures while maintaining minimal A M B I conventional E N T COOL BEAM COOL BEAM energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • Comes standard with Program start PHILIPS/ADVANCE BALLASTS CENTIUM ICN4S5490C-2LSG 1.00 Ballast factor. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • NEC required ballast disconnect is standard.

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

AMBIENT

HIGH FIVE WARRANTY

55ºC

HIGH FIVE WARRANTY 5YR-WARRANTY

HIGH FIVE @ 55

5-YEAR

55ºC

4"

AMBIENT

55ºC

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

55ºC A M B I E N T

HIGH FIVE @ 55

13-3/4"

48-1/2"

LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects.

T5 CB4

55ºC

Ordering Information Example: CB-4-54-T5HO

Cool Beam Fluorescent 4 Lamp T5HO High Bay

CB

4

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

4

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

voltage3

49w/T5HO2

54w/T5HO

(Blank) -

(Blank) ADV-71 ADV-101

-

-

-

-

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

-

ADV-ROVR

-

LUT-EHD

-

-

Lutron Tu-Wire3

-

-

-

LUT-EC31

-

-

-

LUT-H3D1

Lutron Hi-Lume 3D3

-

LUT-ECD

Lutron Ecosystem (347V Only)

order code

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Essential3

WIRING options

Advance Rover

3

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

Lutron Ecosystem3

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

Lutron Eco-103

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

Lutron Ecosystem H-Series

3

Lutron Tve3 1

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

Description

Advance Optanium3

1

ballast factor

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE

1

# of ballast

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

3

1- Requires 2 Ballasts 2- Consult factory for dimming options. 3- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

OTHER options 4WG - Wireguard 4WGCL - Wireguard with Clear Lens 4WGPL - Wireguard with Prismatic Lens 4WGDF - Wireguard with Door frame 4CLDF - Clear Lens with Door Frame 4PLDF - Prismatic Lens with Door Frame 4GDF - Gasketed Door Frame MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit

Standard Ballast info LAMP

# of lamps F54T5H0 4

CH - Chain with S hooks

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

Min. Starting Temp (°F/°C)

VH - V Hook MS - Motion Sensor

-20/ -29

MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 4WHR - White Reflector USA - Made in America Compliance

76

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T5 COOL BEAM FLUORESCENT HIGH BAY (6 LAMP FULL BODY SPECIFICATION GRADE)

CB6

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 6 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • Comes standard with Program start PHILIPS/ADVANCE BALLASTS CENTIUM ICN4S5490C-2LSG(4 lamps), and ICN2S5490C-WL (2 lamps) ballasts 1.15 Ballast factor. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • NEC required ballast disconnect is standard.

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

HIGH FIVE @ 55

5-YEAR

55ºC AMBIENT

4"

HIGH FIVE @ 55

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

5YR-WARRANTY

55ºC A M B I E N T

20"

48-1/2"

T5

Ordering Information Example: CB-6-54-T5HO

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

6

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

CB6

voltage3

49w/T5HO2

54w/T5HO

(Blank) -

(Blank) ADV-71 ADV-101

-

-

Advance Optanium3

-

-

Advance Essential3

-

ADV-ROVR

Advance Rover

-

LUT-EHD

Lutron Ecosystem H-Series

-

-

Lutron Tu-Wire3

-

-

-

LUT-EC31

-

-

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

-

LUT-H3D1

Lutron Hi-Lume 3D3

-

LUT-ECD

Lutron Ecosystem (347V Only)

Description

order code

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options

3

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

Lutron Ecosystem3

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

Lutron Eco-103

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

3

Lutron Tve3 1

ballast factor

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE

1

# of ballast

(Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts 120 277 347 480

3

1- Requires 3 Ballasts 2- Consult factory for dimming options. 3- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

OTHER options 6WG - Wireguard 6WGCL - Wireguard with Clear Lens 6WGPL - Wireguard with Prismatic Lens 6WGDF - Wireguard with Door frame 6CLDF - Clear Lens with Door Frame 6PLDF - Prismatic Lens with Door Frame 6GDF - Gasketed Door Frame MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit

Standard Ballast info LAMP

# of lamps F54T5H0 6

CH - Chain with S hooks

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

Min. Starting Temp (°F/°C)

VH - V Hook MS - Motion Sensor

-20/ -29

MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 6WHR - White Reflector USA - Made in America Compliance

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

77

Cool Beam Fluorescent 6 lamp T5HO High Bay

6

A M B I E N T

HIGH FIVE @ 55

LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects.

CB

5YR WARRANTY

55ºC


T8 COOL BEAM FLUORESCENT HIGH BAY (4 LAMP FULL BODY SPECIFICATION GRADE)

CB4

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

55ºC

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

PRODUCT FEATURES: 55ºC 55ºC • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 4 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • Comes standard with Instant start GE, pro line multi-volt ballast model number GE432-MV-H. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects. HIGH FIVE @ 55

5-YEAR

AMBIENT

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

4" 13-3/4"

48-1/2"

T8 CB4

Ordering Information Example: CB-4-32-T8

Cool Beam Fluorescent 4 Lamp T8 High Bay

CB

4

32-t8

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

4

32-t8 - 32W/T8

voltage2

BALLAST CONFIGURATION & CODE 32w/T8

Description

(Blank) EPS ADV-7 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

# of ballast

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Optanium

EMG-SD-T8-BX-T5-T5HO-1400

ADV-ESS1

Advance Essential2

EMG-ICE-T8-BX-T5-T5HO-1400

ADV-ROVR

Advance Rover2

WIRING options

LUT-EHD1

Lutron Ecosystem H-Series2

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

LUT-2W1

Lutron Tu-Wire2

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

LUT-EC51

Lutron Ecosystem2

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

LUT-EC31

Lutron Eco-102 Lutron Tve2

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

LUT-TVE1 LUT-H3D1

Lutron Hi-Lume 3D2

-

2

Lutron Ecosystem (347V Only)2

1- Requires 2 Ballasts 2- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

Standard Ballast info LAMP F32T8

# of lamps 4

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

lampS installed

ballast factor

(Blank)- High BF (blank) - No lamps (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts NBF- Normal BF L30K - 30K L41K - 41K 120 LBF- Low BF L35K - 35K L50K - 50K 277 347 emergency battery pack options (L. = Lumens) 480 order code DESCRIPTION Up to 450 L. for T8 or BX EMG-T8-BX-450

OTHER options 4WG - Wireguard 4WGCL - Wireguard with Clear Lens 4WGPL - Wireguard with Prismatic Lens 4WGDF - Wireguard with Door frame 4CLDF - Clear Lens with Door Frame 4PLDF - Prismatic Lens with Door Frame 4GDF - Gasketed Door Frame MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit

Min. Starting Temp (°F/°C)

CH - Chain with S hooks VH - V Hook

-22/ -30

MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 4WHR - White Reflector USA - Made in America Compliance

78

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8 COOL BEAM FLUORESCENT HIGH BAY (6 LAMP FULL BODY SPECIFICATION GRADE) 5-YEAR

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

HIGH FIVE WARRANTY

5-YEAR

55ºC AMBIENT

5YR WARRANTY

HIGH FIVE WARRANTY

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

5YR-WARRANTY

55ºC

A M B I E N T

PRODUCT FEATURES: 55ºC 55ºC • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 6 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • Comes standard with 2 Instant start GE, pro line multi-volt ballasts model number GE332-MV-H. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects. HIGH FIVE @ 55

5-YEAR

AMBIENT

CB6

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

4" 20"

48-1/2"

T8

Ordering Information Example: CB-6-32-T8 6

32-t8

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

6

32-t8 -32W T8

voltage2

BALLAST CONFIGURATION & CODE 32w/T8

Description

(Blank) EPS ADV-7 ADV-10

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

# of ballast

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Optanium

EMG-SD-T8-BX-T5-T5HO-1400

ADV-ESS

Advance Essential2

EMG-ICE-T8-BX-T5-T5HO-1400

Advance Rover2

WIRING options

LUT-EHD

Lutron Ecosystem H-Series2

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

LUT-2W1

Lutron Tu-Wire2

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

LUT-EC5

Lutron Ecosystem2 Lutron Eco-102

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

LUT-EC3 LUT-TVE1

Lutron Tve2

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

ADV-ROVR

2

-

Lutron Hi-Lume 3D2

-

Lutron Ecosystem (347V Only)2

1- Requires 3 Ballasts 2- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

Standard Ballast info LAMP F32T8

# of lamps 6

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

lampS installed

ballast factor

(Blank)- High BF (blank) - No lamps (Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts NBF- Normal BF L30K - 30K L41K - 41K 120 LBF Low BF L35K - 35K L50K - 50K 277 347 emergency battery pack options (L. = Lumens) 480 order code DESCRIPTION Up to 450 L. for T8 or BX EMG-T8-BX-450

Min. Starting Temp (°F/°C) -22/ -30

OTHER options 6WG 6WGCL 6WGPL 6WGDF 6CLDF 6PLDF 6GDF

- Wireguard - Wireguard with Clear Lens - Wireguard with Prismatic Lens - Wireguard with Door frame - Clear Lens with Door Frame - Prismatic Lens with Door Frame - Gasketed Door Frame

MH - Mounting Hub GSS GSSP VHCH CH VH MS MSPH GL 6WHR

- Gripple Suspension System - Gripple System with Paddles - V-Hook with chain kit - Chain with S hooks - V Hook - Motion Sensor - Motion Sensor with Photocell - Generic Lamps Installed - White Reflector

USA - Made in America Compliance

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

79

Cool Beam Fluorescent 6 Lamp T8 High Bay

CB

CB6


T8 COOL BEAM FLUORESCENT HIGH BAY (8 LAMP FULL BODY SPECIFICATION GRADE)

CB8

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

55ºC

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

PRODUCT FEATURES: 55ºC 55ºC • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 8 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • Comes standard with 2 Instant start GE, pro line multi-volt ballast model number GE432-MV-H. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects. HIGH FIVE @ 55

5-YEAR

AMBIENT

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

4" 25"

48-1/2"

T8 CB8

Ordering Information Example: CB-8-32-T8

Cool Beam Fluorescent 8 Lamp T8 High Bay

CB

8

32-t8

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

8

32-t8 - 32W/T8

voltage

BALLAST CONFIGURATION & CODE 32w/T8

Description

(Blank) EPS

Electronic Instant Start Electronic Program Start

Consult Factory for other ballast options.

Standard Ballast info LAMP F32T8

# of lamps 8

# of ballast

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

lampS installed

ballast factor

(Blank)- High BF (blank) - No lamps (Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts NBF- Normal BF L30K - 30K L41K - 41K 120 LBF- Low BF L35K - 35K L50K - 50K 277 347 emergency battery pack options (L. = Lumens) 480 order code DESCRIPTION Up to 450 L. for T8 or BX EMG-T8-BX-450

Min. Starting Temp (°F/°C) -22/ -30

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

8WGPL - Wireguard with Prismatic Lens

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

8WGDF - Wireguard with Door frame

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

8WGCL - Wireguard with Clear Lens

8CLDF - Clear Lens with Door Frame 8PLDF - Prismatic Lens with Door Frame 8GDF - Gasketed Door Frame MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 8WHR - White Reflector USA - Made in America Compliance

80

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T5 COOL BEAM FLUORESCENT HIGH BAY (8 LAMP FULL BODY SPECIFICATION GRADE)

CB8

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 8 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • Comes standard with 2 Program start PHILIPS/ADVANCE BALLASTS CENTIUM ICN4S5490C-2LSG. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects.

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

4"

HIGH FIVE @ 55

5-YEAR

55ºC AMBIENT

HIGH FIVE @ 55

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

55ºC A M B I E N T

HIGH FIVE @ 55

25"

48-1/2"

T5

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

8

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

voltage

ballast factor

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

49w/T5HO

order code

54w/T5HO Description (Blank)

Electronic Instant Start Electronic Program Start

Consult Factory for other ballast options.

Standard Ballast info # of lamps F54T5H0 8

# of ballast

(Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts 120 277 347 480

BALLAST CONFIGURATION & CODE (Blank)

LAMP

CB8

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options Min. Starting Temp (°F/°C) -20/ -29

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

8WGPL - Wireguard with Prismatic Lens

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

8WGDF - Wireguard with Door frame

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

8WGCL - Wireguard with Clear Lens

8CLDF - Clear Lens with Door Frame 8PLDF - Prismatic Lens with Door Frame 8GDF - Gasketed Door Frame MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 8WHR - White Reflector USA - Made in America Compliance

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

81

Cool Beam Fluorescent 8 Lamp T5HO High Bay

8

A M B I E N T

5YR-WARRANTY

Ordering Information Example: CB-8-54-T5HO CB

5YR WARRANTY

55ºC


T8 COOL BEAM FLUORESCENT HIGH BAY (10 LAMP FULL BODY SPECIFICATION GRADE)

CB10

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY

55ºC

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

5YR-WARRANTY

A M B I E N T

PRODUCT FEATURES: 55ºC 55ºC • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 2 push buttons located on ends of fixture which allows lamps and reflector to hinge down for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 10 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Comes standard with 2 Instant start GE, pro line multi-volt ballast model number GE432-MV-H and 1 GE232-MV-H. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects. HIGH FIVE @ 55

5-YEAR

AMBIENT

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

3-3/4" 23-1/2"

49"

T8 CB10

Ordering Information Example: CB-10-32-T8

Cool Beam Fluorescent 10 Lamp T8 High Bay

CB

10

32-t8

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

10

32-t8 - 32W/T8

voltage

BALLAST CONFIGURATION & CODE

F32T8

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

Description

order code

(Blank) EPS

Electronic Instant Start Electronic Program Start

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Standard Ballast info # of lamps 10

ballast factor

32w/T8

Consult Factory for other ballast options.

LAMP

# of ballast

(Blank) - MVOLT (120/277) (Blank) -3 Ballast 4 -4 Ballasts 120 277 347 480

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

Min. Starting Temp (°F/°C) -22/ -30

WIRING options

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

10CLDF - Clear Lens with Door Frame

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

10PLDF - Prismatic Lens with Door Frame

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

10WG - Wireguard

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 10WHR - White Reflector USA - Made in America Compliance

82

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T5 COOL BEAM FLUORESCENT HIGH BAY (10 LAMP FULL BODY SPECIFICATION GRADE)

CB10

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 2 push buttons located on ends of fixture which allows lamps and reflector to hinge down for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 10 lamp CB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Comes standard with 2 Program start PHILIPS/ADVANCE BALLASTS CENTIUM ICN4S5490C-2LSG and 1 ICN2S5490C-2LSG. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects.

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

4"

HIGH FIVE @ 55

5-YEAR

55ºC AMBIENT

HIGH FIVE @ 55

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

55ºC A M B I E N T

HIGH FIVE @ 55

26-1/8"

47"

T5

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

10

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

54-t5ho voltage

ballast factor

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

49w/T5HO

order code

54w/T5HO Description (Blank)

Electronic Instant Start Electronic Program Start

Consult Factory for other ballast options.

Standard Ballast info # of lamps F54T5H0 10

# of ballast

(Blank) - MVOLT (120/277) (Blank) -3 Ballast 4 -4 Ballasts 120 277 347 480

BALLAST CONFIGURATION & CODE (Blank)

LAMP

CB10

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options Min. Starting Temp (°F/°C) -20/ -29

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

10CLDF - Clear Lens with Door Frame

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

10PLDF - Prismatic Lens with Door Frame

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

10WG - Wireguard

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 10WHR - White Reflector USA - Made in America Compliance

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

83

Cool Beam Fluorescent 10 Lamp T5HO High Bay

10

A M B I E N T

5YR-WARRANTY

Ordering Information Example: CB-10-54-T5HO CB

5YR WARRANTY

55ºC


CB12

T5 COOL BEAM FLUORESCENT HIGH BAY (12 LAMP FULL BODY SPECIFICATION GRADE) S H I P P I N G AVA I L A B L E

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

AMBIENT

HIGH FIVE WARRANTY

HIGH FIVE WARRANTY

PRODUCT FEATURES: • Our Cool Beam Technology allows ballast to stay cool through ventilation slots on sides, and to maintain 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 2 push buttons located on ends of fixture which allows lamps and reflector to hinge down for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion 5YR WARRANTY 5YR WARRANTY and rust resistance. • Using A the optical technology our 12 lamp CB luminaire out M B I E Nlatest T A M B I E N T COOL BEAM COOL BEAM conventional MH fixtures while maintaining minimal 55ºC performs energy consumption. • Comes standard with 3 Program start PHILIPS/ADVANCE BALLASTS CENTIUM ICN4S5490C-2LSG. • Assembled in the USA. • Qualifies for most national and regional utility rebates. • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects.

55ºC

5YR-WARRANTY

5"

HIGH FIVE @ 55

5-YEAR

55ºC AMBIENT

HIGH FIVE @ 55 5YR-WARRANTY

55ºC A M B I E N T

HIGH FIVE @ 55

32"

48-1/2"

T5 CB12

55ºC

A M B I E N T

Ordering Information Example: CB-12-54-T5HO

Cool Beam Fluorescent 12 Lamp T5HO High Bay

CB

12

series

LAMPS

lamp type

CB - Oracle Cool Beam Industrial Series

12

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

voltage

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens)

49w/T5HO

order code

54w/T5HO Description (Blank)

Electronic Instant Start Electronic Program Start

Consult Factory for other ballast options.

Standard Ballast info # of lamps F54T5H0 12

ballast factor

BALLAST CONFIGURATION & CODE (Blank)

LAMP

# of ballast

(Blank) - MVOLT (120/277) (Blank) -3 Ballast 4 -4 Ballasts 120 277 347 480

EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

Min. Starting Temp (°F/°C) -20/ -29

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

12CLDF - Clear Lens with Door Frame

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

12PLDF - Prismatic Lens with Door Frame

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

12WG - Wireguard

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed 12WHR - White Reflector USA - Made in America Compliance

84

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 2X4 RECESSED COOL BEAM FLUORESCENT (4, 6 LAMP) 5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

ORCB

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

55ºC

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

PRODUCT FEATURES: 55ºC 55ºC • Our Cool Beam Technology allows ballast to stay cool and maintain a 5 year warranty at 55ºC. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. • Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard is standard white finish and may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as emergency ballasts, lamps and wiring all come prewired from factory. • 95% reflective premium reflector material is engineered to optimize performance for 93% total fixture efficiency • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 6 lamp ORCB luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for safety wire support when required. Built in earthquake clips standard. • T5 comes standard with Program start PHILIPS/ADVANCE BALLASTS CENTIUM ICN4S5490C-2LSG(4 lamps), and ICN2S5490C-WL (2 lamps) ballasts 1.15 Ballast factor. • T8 comes standard with 2 Instant start GE, pro line multi-volt ballasts model number GE332-MV-H • Assembled in the USA. • Qualifies for most national and regional utility rebates. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for five years against mechanical defects. HIGH FIVE @ 55

5-YEAR

AMBIENT

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

4-1/2"

23-3/4"

48"

T8/T5

Ordering Information Example: 24-ORCB-6-32-T8

ORCB

ORCB series

LAMPS

lamp type

24 - 2’ X 4’

ORCB - Oracle Recessed Cool Beam

4 6

32-t8 -32W T8 49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

voltage3

BALLAST CONFIGURATION & CODE 49w/T5HO2

54w/T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-71 ADV-101

-

-

-

Advance Optanium3

ADV-ESS

-

-

Advance Essential3

ADV-ROVR

-

ADV-ROVR

Advance Rover3

LUT-EHD

-

LUT-EHD1

Lutron Ecosystem H-Series3

LUT-2W1

-

-

Lutron Tu-Wire3

LUT-EC5

-

-

Lutron Ecosystem

LUT-EC3

-

LUT-EC31

-

-

LUT-H3D1

-

-

-

order code

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

3

Lutron Eco-103 Lutron Tve3

WIRING options

LUT-H3D1

Lutron Hi-Lume 3D3

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

LUT-ECD1

Lutron Ecosystem (347V Only)3

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

Standard Ballast info # of lamps F32T8 4, 6 F54T5H0 4, 6

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

Description

1- Requires 3 Ballasts 2- Consult factory for dimming options. 3- Voltage must be specified for dimming ballast.

LAMP

lampS installed

ballast factor

emergency battery pack options (L. = Lumens)

32w/T8

LUT-TVE1

# of ballast

(Blank)- High BF (Blank) - MVOLT (120/277) 4 lamps NBF- Normal BF (Blank) -1 Ballast 120 LBF- Low BF 2 -2 Ballasts 277 347 6 lamps (Blank) -2 Ballast 480 3 -3 Ballasts

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10 120/ 277 1 98 10

WWW. ORACLELIGHTING . COM

Min. Starting Temp (°F/°C) -22/ -30 -20/ -29

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

OTHER options RWGCL RWGPL RWGDF RCLDF RPLDF RGDF GL RWHR

- Wireguard with Clear Lens - Wireguard & A12 Prismatic Lens - Wireguard with Door frame - Clear Lens with Door Frame - A12 Prismatic Lens with Door Frame - Gasketed Door Frame - Generic Lamps Installed - White Reflector

USA - Made in America Compliance

(Consult Factory for 208V, 248V, 347V and 480V wiring)

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

85

Fluorescent 6 Lamp Recessed Cool Beam

FIXTURE SIZE


GHB

T5 GENERAL PURPOSE FLUORESCENT HIGH BAY (4 LAMP SURFACE & SUSPENDED MOUNT FULL BODY)

CB

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Ventilation slots on sides help to maintain 1 year warranty. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 85% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 4 lamp luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • NEC required ballast disconnect is standard.

4"

LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for one year against mechanical defects.

13-3/4"

48-1/2"

T5 GHB

Ordering Information Example: ghb-4-54-T5HO

General Purpose Fluorescent 4 Lamp High Bay

GHB

4

series

LAMPS

lamp type

GHB - Oracle General Purpose High Bay

4

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

voltage3

# of ballast

ballast factor

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

49w/T5HO2

54w/T5HO

(Blank) -

(Blank) ADV-71 ADV-101

-

-

-

-

-

ADV-ROVR

-

LUT-EHD1

-

LUT-EC31

-

-

-

LUT-H3D

Lutron Hi-Lume 3D

-

LUT-ECD1

Lutron Ecosystem (347V Only)3

Description Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103 Advance Optanium3 Advance Essential3

order code EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Rover

WIRING options

Lutron Ecosystem H-Series3

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

4GHBWG - Wireguard

-

Lutron Tu-Wire3

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

4GHBCL - Clear Lens

-

Lutron Ecosystem3

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

1

3

Lutron Eco-103 Lutron Tve3

1

3

1- Requires 2 Ballasts 2- Consult factory for dimming options. 3- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

OTHER options

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GMS - Generic Motion Sensor 4WHR - White Reflector

86

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T5 GENERAL PURPOSE FLUORESCENT HIGH BAY (6 LAMP SURFACE & SUSPENDED MOUNT FULL BODY)

GHB

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Ventilation slots on sides help to maintain 1 year warranty. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 85% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 6 lamp luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for one year against mechanical defects.

4" 20"

48-1/2"

T5

Ordering Information Example: GHB-6-54-T5HO 6

series

LAMPS

lamp type

GHB - Oracle General Purpose High Bay

6

49-t5h0 - 49W T5HO 54-t5h0 - 54W T5HO

voltage3

# of ballast

ballast factor

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

(Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts 120 277 347 480

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

49w/T5HO2

54w/T5HO

(Blank) -

(Blank) ADV-71 ADV-101

-

-

Advance Optanium3

-

-

Advance Essential3

-

ADV-ROVR

Advance Rover

WIRING options

-

LUT-EHD1

Lutron Ecosystem H-Series3

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

6GHBWG - Wireguard

-

-

Lutron Tu-Wire3

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

6GHBCL - Clear Lens

-

-

Lutron Ecosystem3

- 10’ Nema L5-15R 120V Twist Lock Plug

-

LUT-EC31

PCTL120

-

-

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

-

LUT-H3D

Lutron Hi-Lume 3D

-

LUT-ECD1

Lutron Ecosystem (347V Only)3

Description Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

3

Lutron Eco-103 Lutron Tve3

1

General Purpose Fluorescent 6 Lamp High Bay

GHB

GHB

order code EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

3

1- Requires 3 Ballasts 2- Consult factory for dimming options. 3- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

OTHER options

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GMS - Generic Motion Sensor 6WHR - White Reflector

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

87


GHB

T8 GENERAL PURPOSE FLUORESCENT HIGH BAY (4 LAMP SURFACE & SUSPENDED MOUNT FULL BODY) S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Ventilation slots on sides help to maintain 1 year warranty. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 85% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 4 lamp luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

4" 13-3/4"

LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for one year against mechanical defects. 48-1/2"

T8 GHB

Ordering Information Example: GHB-4-32-T8

General Purpose Fluorescent 4 Lamp High Bay

GHB

4

32-t8

series

LAMPS

lamp type

GHB - Oracle General Purpose High Bay

4

32-t8 - 32W/T8

voltage2

# of ballast

ballast factor

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

32w/T8

Description

order code

(Blank) EPS ADV-7 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Optanium2

ADV-ESS1

Advance Essential2

ADV-ROVR

Advance Rover

LUT-EHD1

Lutron Ecosystem H-Series2

2

LUT-2W1

Lutron Tu-Wire2

LUT-EC51

Lutron Ecosystem2

LUT-EC31

Lutron Eco-102

LUT-TVE1

Lutron Tve2

LUT-H3D1 -

OTHER options

WIRING options PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

4GHBWG - Wireguard

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

4GHBCL - Clear Lens

Lutron Hi-Lume 3D2

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

Lutron Ecosystem (347V Only)2

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

1- Requires 2 Ballasts 2- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GMS - Generic Motion Sensor 4WHR - White Reflector

88

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8 GENERAL PURPOSE FLUORESCENT HIGH BAY(6 LAMP SURFACE & SUSPENDED MOUNT FULL BODY)

GHB

S H I P P I N G AVA I L A B L E

PRODUCT FEATURES: • Ventilation slots on sides help to maintain 1 year warranty. • Full Body construction is formed from 22 Gauge steel to ensure rigidity and endurance. Body includes knockouts on top and sides for easy wiring. • Reflector is attached to body with 4 screws, and hinges down along with lamps for easy access to ballast. Rotary Lamp sockets hold lamps in place and allow for easy relamping. • Wireguard may be combined with lens option. Wireguard and lens option come preinstalled with hinged doorframe for easy access to lamps. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • 85% reflective premium reflector material is engineered to optimize performance. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Using the latest optical technology our 6 lamp luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Four corner tie points are standard for chain or aircraft cable mount. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard.

4" 20"

LISTING - UL/ C-UL listed for damp location. WARRANTY - Guaranteed for one year against mechanical defects.

48-1/2"

T8

Ordering Information Example: GHB-6-32-T8 6

32-t8

series

LAMPS

lamp type

GHB - Oracle General Purpose High Bay

6

32-t8 -32W T8

voltage2

# of ballast

ballast factor

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

(blank) - No lamps L30K - 30K L41K - 41K L35K - 35K L50K - 50K

(Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts 120 277 347 480

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens)

32w/T8

Description

order code

(Blank) EPS ADV-7 ADV-10

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Optanium2

ADV-ESS

Advance Essential2

ADV-ROVR LUT-EHD

Advance Rover

2

Lutron Ecosystem H-Series2

LUT-2W1

Lutron Tu-Wire2

LUT-EC5

Lutron Ecosystem2

LUT-EC3

Lutron Eco-102

LUT-TVE1

Lutron Tve2

LUT-H3D1

Lutron Hi-Lume 3D2

-

Lutron Ecosystem (347V Only)2

General Purpose Fluorescent 6 Lamp High Bay

GHB

GHB

WIRING options

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

6GHBWG - Wireguard

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

6GHBCL - Clear Lens

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

1- Requires 3 Ballasts 2- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

MH - Mounting Hub GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GMS - Generic Motion Sensor 6WHR - White Reflector

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

89


T8/T5, SONIC BEAM FLUORESCENT HIGH BAY (4, 6 AND 8 LAMP T5HO & T8)

SB

5-YEAR

5-YEAR

55ºC

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

AMBIENT

HIGH FIVE WARRANTY

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

55ºC

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

PRODUCT FEATURES: 55ºC 55ºC • Code gauge steel is utilized throughout housing to resist the most demanding environments. • Highly tooled 95% reflective premium reflector material is engineered to optimize the thermal and luminous environment. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Rotary lamp sockets retain lamp from falling and ensure proper contact. • Ballast can be accessed from below the ceiling by removing quarter turn fasteners located in center channel. • Additional options such as motion sensors, emergency ballasts, lamps and wiring all come prewired from factory. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • Low profile design provides a crisp, clean look and allows air to flow smoothly to the ballast. • Captive-bolt ballast mounting allows front access to ballast. • Four corner tie points are standard for safety wire support when required. • Suitable for suspension by Chain, cable, pendant, or can also be surface mounted. • Shield Beam fixtures are warranted for ambient environments up to 55ºC for 5 years. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects. HIGH FIVE @ 55

5-YEAR

AMBIENT

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

4 Lamps

14-3/4" 6 & 8 Lamps

19-1/2" 2-3/4" 48"

T8/T5 SB

Ordering Information Example: SB-4-32-T8 sB

Sonic Beam Fluorescent 4, 6, 8 Lamp High Bay

series

LAMPS

SB - Oracle Sonic Beam Industrial Series

4 6 8

lamp type

voltage

32-t8 - 32W T8 54-T5HO - 54W T5HO

# of ballast

(Blank) - MVOLT (120/277) 4 lamps (Blank) -1 Ballast 120 2 -2 Ballasts 277 347 6,8 lamps (Blank) -2 Ballast 480 3 -3 Ballasts

ballast factor

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens) order code

BALLAST CONFIGURATION & CODE 32w/T8

54w/T5HO

(Blank) EPS

(Blank)

Description Electronic Instant Start Electronic Program Start

Consult Factory for other ballast options.

Standard Ballast info LAMP F32T8 F54T5H0

# of lamps 4, 6, 8

Line volts 120/ 277

4, 6, 8

120/ 277

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options Ballast Factor

Power Factor% (>=)

THD% (<=)

Min. Starting Temp (°F/°C)

1.15

99

10

-22/ -30

1

98

10

-20/ -29

PCSB120 - 10’ Nema 5-15R 120V Straight Blade Plug PCSB277 - 10’ Nema 7-15R 277V Straight Blade Plug PCTL120 - 10’ Nema L5-15R 120V Twist Lock Plug PCTL277 - 10’ Nema L7-15R 277V Twist Lock Plug SO1 - 10’ 120V/277V SO Cord SO2 - 10’ 480V SO Cord C3 - 6’ 3-wire Flex Cable (Single Circuit) C4 - 6’ 4-wire Flex Cable (Double Circuit) (Consult Factory for 208V, 248V, 347V and 480V wiring)

OTHER options WG - Wireguard GSS - Gripple Suspension System GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell SRUL - Specular Reflector Uplight GL - Generic Lamps Installed USA - Made in America Compliance

90

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8/T5, 4’ & 8’ SHIELD BEAM FLUORESCENT HIGH BAY (2, 3, 4, 6 AND 8 LAMP) WITH CROSS BAFFLE 5-YEAR

55ºC AMBIENT

S H I P P I N G AVA I L A B L E

HIGH FIVE WARRANTY

SHIELD

5-YEAR

55ºC AMBIENT

5YR WARRANTY

HIGH FIVE WARRANTY 5YR-WARRANTY

55ºC

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

A M B I E N T

APPLICATION: 55ºC 55ºC Oracle Shield Beam High Bays are ideal for any retail application that requires great performance with the capabilities to reduce glare in typical high bays. Other applications includes schools, warehouses and offices. PRODUCT FEATURES: • Fixture is designed with a flat blade cross baffle to provide high viewing lamp shielding to reduce brightness and glare. • Oracle shield Beam Fluorescent High Bay offers a great alternative to traditional Metal Halide fixtures. • Channel is formed of code gauge steel to resist the most demanding environments. • Constructed of one-piece ribbed unitized housing and corners that interlock to prevent aesthetically damage to fixture.. • Post painted high-gloss enamel finish ensures maximum adhesion and rust resistance. • Hinged doorframe allows for easy relamping and maintenance. • All sides and corners are turned in and hemmed removing sharp edges for safe handling and installation. • High efficiency premium grade reflector is slotted to provide 20% uplight. • Comes standard with GE pro line multi-volt ballast (120/277V) for T8 models or Advance High Temperature Centium electronic 120-277V ballast for T5HO. • Suitable for suspension by Chain, cable, pendant, or can also be surface mounted. • Using the latest optical technology our shield Beam luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects. 5-YEAR

AMBIENT

HIGH FIVE @ 55

SDB

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

HIGH FIVE @ 55

4-1/2" 10-1/8"

2, 3 or 4 Lamps

48-1/8"

4, 6 or 8 Lamps (Tandem)

96-1/4"

T8/T5

Ordering Information Example: 8-SDB-6-32-T8

SDB

SDB FIXTURE SIZE

series

LAMPS

lamp type

voltage

SDB - Oracle 4’ fixture 32-t8 - 32W T8 2 Shield Beam 28-T5 - 28W T5 3 Industrial 54-T5HO - 54W T5HO 4 Series 8’ TANDEM fixture 4 6 8

# of ballast

ballast factor

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

(Blank) - MVOLT (120/277) 2, 3, 4 lamps (Blank) -1 Ballast 120 2 -2 Ballasts 277 347 6,8 lamps (Blank) -2 Ballast 480 3 -3 Ballasts

emergency battery pack options (L. = Lumens) order code

BALLAST CONFIGURATION & CODE 32w/T8

54w/T5HO

(Blank) EPS

(Blank)

Description Electronic Instant Start Electronic Program Start

Consult Factory for Advance & Lutron dimming options.

Standard Ballast info LAMP F32T8 F54T5H0

# of Line lamps volts 2, 3, 4, 6, 8 120/ 277 2, 3, 4, 6, 8

120/ 277

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options Ballast Factor

Power Factor% (>=)

THD% (<=)

Min. Starting Temp (°F/°C)

1.15

99

10

-22/ -30

1

98

10

-20/ -29

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

MH - Mounting Hub

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

GSS - Gripple Suspension System

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

(Consult Factory for 208V, 248V, 347V and 480V wiring)

GSSP - Gripple System with Paddles VHCH - V-Hook with chain kit CH - Chain with S hooks VH - V Hook MS - Motion Sensor MSPH - Motion Sensor with Photocell GL - Generic Lamps Installed NCB - No Cross Baffle USA - Made in America Compliance

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

91

Shield Beam Fluorescent 2, 3, 4, 6, 8 Lamp High Bay

4 - 4’ 8 - 8’


DHB

T8/T5 DECORATIVE COOL BEAM (4, 6 LAMP WITH UP-LIGHT FEATURE) 5-YEAR

55ºC AMBIENT

HIGH FIVE WARRANTY

5-YEAR

55ºC AMBIENT

5YR WARRANTY

HIGH FIVE WARRANTY

5-YEAR

55ºC AMBIENT

HIGH FIVE @ 55

5YR WARRANTY

55ºC

55ºC

COOL BEAM

COOL BEAM

A M B I E N T

5YR-WARRANTY

55ºC

A M B I E N T

APPLICATION: For 55ºC use as a high bay and/or low bay applications. Warehouses, retail stores, multi-tenant office/warehouse complexes, big box wholesale centers, distribution facilities. HIGH FIVE @ 55

HIGH FIVE @ 55

A M B I E N T

5YR-WARRANTY

A M B I E N T

PRODUCT FEATURES: • 12% uplight contribution will illuminate ceilings and working areas above the fixture. • DHB utilizes both acrylic and metal reflector design concepts to meet the needs for both low bay and high bay applications • ENDCAPS – high impact injection molded ABS end cap provides a sleek finish for any application • Suitable for suspension by Chain, cable, pendant, or can also be surface mounted • Light weight design enables easier installation. • CEE qualified ballast found standard on most fixture options (Consult factory for details). • NEC required ballast disconnect is standard. 4 Lamps

4"

REFLECTOR CHOICES • High reflectance white • 95% specular silver reflector (Standard)

13-3/4"

SHOULDERS • Linear acrylic reflector design combines efficient reflection and refraction to manage brightness while delivering even indirect illuminations

6 Lamps 4" 16-1/4"

T8/T5 DHB

LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects.

48"

Ordering Information Example: DHB-4-32-T8 DHB

Decorative 4 & 6 Lamp Cool Beam High Bay

series

LAMPS

DHB - Oracle Decorative Cool Beam

4 6

voltage

lamp type

# of ballast

ballast factor

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

(Blank) - MVOLT (120/277) 4 lamps (Blank) -1 Ballast 120 2 -2 Ballasts 277 347 6 lamps -2 Ballast (Blank) 480 3 -3 Ballasts

32-t8 - 32W T8 54-T5HO - 54W T5HO

emergency battery pack options (L. = Lumens) order code

BALLAST CONFIGURATION & CODE 32w/T8

54w/T5HO

(Blank) EPS

(Blank)

Description Electronic Instant Start Electronic Program Start

Consult Factory for other ballast options.

Standard Ballast info LAMP F32T8 F54T5H0

# of lamps 4, 6

Line volts 120/ 277

4, 6

120/ 277

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options Ballast Factor

Power Factor% (>=)

THD% (<=)

Min. Starting Temp (°F/°C)

1.15

99

10

-22/ -30

1

98

10

-20/ -29

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

CH

- Heavy Duty Chain

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

MS

- Motion Sensor

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

MH

- Mounting Hub

SO1

- 10’ 120V/277V SO Cord

GSS

- Gripple Suspension System

SO2

- 10’ 480V SO Cord

VH

C3

- 6’ 3-wire Flex Cable (Single Circuit)

C4

- 6’ 4-wire Flex Cable (Double Circuit)

WR -White Reflector USA - Made in America Compliance

MSPH

- Motion Sensor with Photocell

- V Hook

(Consult Factory for 208V, 248V, 347V and 480V wiring)

92

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


DHB 4-LAMP T5 AND T8 PHOTOMETRIC DATA COOL BEAM SERIES FIXTURE

TOTAL EFFICACY

% UPLIGHT

4 Lamp T8 W/Specular Reflector

89.9

12%

DHB

4 Lamp T8 W/White Reflector

88.3

12%

DHB

4 Lamp T5 W/Specular Reflector

88.2

12%

DHB

4 Lamp T5 W/White Reflector

87.0

12%

DHB

DHB-4-32-T8-WR

Lamps: (4) 32W T8 FO32/835 Linear Fluorescents ZONAL LUMEN SUMMARY ZONE LUMENS %BARELAMP %LUMINAIRE 0-30 2242 19.0 20.2 3734 0-40 31.6 33.7 6939 0-60 58.8 62.6 9779 0-90 82.9 88.3 90-120 361 3.1 3.3 90-130 513 4.3 4.6 90-150 920 7.8 8.3 90-180 1300 11.0 11.7 0-180 11079 93.9 100.0 COEFFICIENTS OF UTILIZATION

105º

90º

75º 1350 60º

2700 0º

15º

45º

30º

10 98 77 62 51 43 37 32 28 25 22 20

90º

75º 1200 60º

2400 45º

3000 0º

COEFFICIENTS OF UTILIZATION

DHB-4-54-T5HO

Candlepower Curve 165º

150º

Lamps: (4) 54W T5 FP54/835/HO Linear Fluorescents

135º

0 45 90 120º

2450 105º

90º

75º 2450 60º

4900 0º

ZONAL LUMEN SUMMARY ZONE LUMENS %BARELAMP %LUMINAIRE 0-30 2753 23.3 24.0 4462 0-40 37.8 38.9 0-60 7754 65.7 67.7 0-90 10300 87.3 89.9 90-120 314 2.7 2.7 90-130 441 3.7 3.8 90-150 803 6.8 7.0 90-180 1159 9.8 10.1 0-180 11459 97.1 100.0

0 45 90

15º

30º

CEILING CAVITY REFLECTANCE Room 80 70 50 Cavity Ratio 70 50 30 10 70 50 30 10 50 30 10 0 113 113 113 113 109 109 109 109 102 102 102 1 103 98 93 89 99 94 90 87 88 85 82 2 93 85 78 72 89 82 76 70 77 72 67 3 85 74 66 60 81 72 64 58 68 61 56 4 77 66 57 50 74 64 56 49 60 53 48 5 71 59 50 43 68 57 49 43 54 47 41 6 66 53 44 38 63 51 43 37 48 41 36 7 61 48 39 33 59 46 38 33 44 37 32 8 57 44 35 30 55 42 35 29 40 33 28 9 53 40 32 27 51 39 31 26 37 30 26 10 50 37 29 24 48 36 29 24 34 28 23

50 30 98 80 67 56 48 42 37 33 30 27 25

Candlepower Curve

Lamps: (4) 32W T8 FO32/835 Linear Fluorescents

1350

CEILING CAVITY REFLECTANCE Room 80 70 50 Cavity Ratio 70 50 30 10 70 50 30 10 50 30 10 0 115 115 115 115 111 111 111 111 103 103 103 1 105 100 96 92 101 96 92 89 90 87 84 2 95 86 79 74 91 83 77 72 78 73 68 3 86 75 67 60 82 73 65 59 68 62 56 4 78 66 57 51 75 64 56 50 60 53 48 5 72 59 50 43 69 57 49 42 53 46 41 6 66 53 44 37 63 51 43 37 48 41 35 7 61 48 39 33 59 46 38 32 44 36 31 8 57 43 35 29 55 42 34 28 40 33 28 9 53 40 31 26 51 39 31 25 36 30 25 10 50 36 29 23 48 35 28 23 34 27 22

WWW. ORACLELIGHTING . COM

135º

120º

Lamps: (4) 54W T5 FP54/835/HO Linear Fluorescents4900 180º

COEFFICIENTS OF UTILIZATION

150º

0 45 90

DHB-4-54-T5HO-WR

ZONAL LUMEN SUMMARY ZONE LUMENS %BARELAMP %LUMINAIRE 0-30 4241 21.2 21.3 7045 0-40 35.2 35.4 13012 0-60 65.1 65.4 17309 0-90 86.5 87.0 90-120 678 3.4 3.4 90-130 986 4.9 5.0 90-150 1845 9.3 9.2 90-180 2594 13.0 13.0 0-180 19903 99.5 100.0

165º

15º

30º

45º

ZONAL LUMEN SUMMARY ZONE LUMENS %BARELAMP %LUMINAIRE 5719 0-30 28.6 28.3 8961 0-40 44.8 44.4 0-60 14536 72.7 72.0 0-90 17800 89.0 88.2 90-120 605 3.0 3.0 90-130 882 4.4 4.4 90-150 1673 8.3 8.4 90-180 2379 11.9 11.8 0-180 20179 100.9 100.0 COEFFICIENTS OF UTILIZATION

T8/T5 DHB

Candlepower Curve 0 45 90

90º

75º 3000 60º

6000 45º

9000 0º

15º

30º

CEILING CAVITY REFLECTANCE Room 80 70 50 Cavity Ratio 70 50 30 10 70 50 30 10 50 30 10 0 117 117 117 117 113 113 113 113 106 106 106 1 108 103 99 96 104 100 96 93 93 90 88 2 98 91 84 79 95 88 82 77 82 77 73 3 90 80 72 66 87 78 70 65 73 67 62 4 83 71 63 57 80 69 61 55 65 59 53 5 76 64 55 49 73 62 54 48 59 52 47 6 71 58 49 43 68 56 48 42 53 46 41 7 66 53 44 38 63 51 43 38 49 42 37 8 61 48 40 34 59 47 39 34 45 38 33 9 57 44 36 31 55 43 36 31 41 34 30 10 54 41 33 28 52 40 33 28 38 32 27

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

93

Decorative 4 & 6 Lamp Cool Beam High Bay

CEILING CAVITY REFLECTANCE Room 80 70 Cavity Ratio 70 50 30 10 70 50 30 10 50 0 109 109 109 109 105 105 105 105 98 1 98 93 89 84 94 90 86 82 84 2 88 80 73 67 85 77 71 65 72 3 80 69 61 55 77 67 60 54 63 4 73 61 52 46 70 59 51 45 55 5 67 54 45 39 64 53 44 38 49 6 62 49 40 34 59 47 39 33 44 7 57 44 35 29 55 43 35 29 40 8 53 40 32 26 51 39 31 26 37 9 49 36 29 23 47 35 28 23 34 10 46 34 26 21 44 33 25 21 31

DHB-4-32-T8

Candlepower Curve 180º 2700


Wet Location Enclosed Gasketed 65,66,67

WET LOCATION Wet rated certification (IP 65 /67) is often required in outdoor and indoor lighting applications, Elites vapor tight and hydro beam series of lighting fixtures meet the high demands of this requirement and more, we also meet ratings for NSF splash zone 2, hose down â&#x20AC;&#x201C; 1300 PSI and Nema â&#x20AC;&#x201C; 4X.

FOOD PROCESSING FACILITIES

SAFETY Fully enclosed and gasketed linear fluorescent luminaries are an excellent product choice for all food processing/food handling environments. Elite offers several fixture styles that meet the need of this industry. Our fixtures and IP6S and/ or IP67 rated for wet location and are approved/ listed by UL (Underwriters Laboratory) NSF (National Sanitation Foundation) International and the Canadian Standards Association Dept. of Agriculture. Food Processing Meat Packing Bottling Centers Cheese Factories Produce Centers Fish Packing Bakeries 94

UP TO

88%

EFFICIENCY

Protection from broken lamps is always a necessity in and around workplace environments where accidental contact with fixtures is a risk. Also, recreational areas such as, gymnasiums, sports facilities, etc. are vulnerable to the possibility of impact and possible breakage. High-impact polycarbonate plastics are used on all of the Elite (our) enclosed housing fixtures to ensure that safety is a must.


95


A- The first IP Character represents the protection against hazardous parts and solid foreign objects. B- The second IP Character represents the protection against water ingress. IP First Character

1

3

3R

3S

4

4X

5

6

6P 12

IP Second Character

12K 13

IP0_

IP_0

IP1_ IP2_ IP3_ IP4_ IP5_ IP6_

IP_1 IP_2 IP_3 IP_4 IP_5 IP_6 IP_7 IP_8 A

96

2

B

A

B

A

B

A

B

A

B

A

B

A

WWW.ORACLELIGHTING .COM

B

A

B

A

B

A

B

A

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

B

A

B

A

B

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


A Brief Comparison of NEMA 250 and IEC 60529 WHAT IS AN “IP CODE?” The IP Code is designation that indicates the level, or amount, of the protection. The IP Code designation consists of the letters IP (International Protection) followed by two numerals. WHAT DOES THE FIRST NUMERAL OF AN IP CODE INDICATE? The first characteristic numeral indicates the degree of protection provided by the enclosure with respect to persons having access to hazardous parts and with respect to solid foreign objects entering the enclosure. The first number specifies the following as described in Table 1.

TABLE 1 First Characteristic Numeral

With Respect to Persons

With Respect to Solid Foreign Objects

0

Non-protected.

Non-protected.

1

Protected against access to hazardous with the back of the hand.

Protected against solid foreign objects > _ 50 mm diameter.

2

Protected against access to hazardous parts with a finger.

_ Protected against solid foreign objects > 12.5 mm diameter.

3

Protected against access to hazardous parts with a tool.

Protected against solid foreign objects > _ 2.5 mm diameter.

4

Protected against access to hazardous parts with a wire.

_ Protected against solid foreign objects > 1.0 mm diameter.

5

Protected against access to hazardous parts with a wire.

Dust-protected (Dust shall not penetrate in quantity to interfere with satisfactory operation of the apparatus or to impair safety).

6

Protected against access to hazardous parts with a wire.

Dust-tight (No ingress of dust).

WHAT DOES THE SECOND NUMERAL OF AN IP CODE INDICATE? The second characteristic numeral indicates the degree of protection provided by the enclosure with respect to the harmful ingress of water. The second number specifies the following as described in Table 2.

TABLE 2 Second Characteristic Numeral

With respect to the Harmful Ingress of Water

0

Non-protected.

1

Protected against vertically falling water drops.

2

Protected against vertically falling water drops when enclosure titled Up to 150.

3

Protected against spraying water.

4

Protected against splashing water.

5

Protected against water jets.

6

Protected against powerful water jets.

7

Protected against the effects of temporary immersion in water.

8

Protected against the effects of continuous immersion in water.

WWW. ORACLELIGHTING . COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

97


HD1B

T5 HYDRO BEAM FLUORESCENT IP & NEMA RATED HIGH BAY WIDE BODY (4 LAMP T5) S H I P P I N G AVA I L A B L E

65,67

6-3/4" 17-1/4"

HD1B

LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects.

51”

T5

APPLICATION: Food processing facilities, sports complexes, warehouses, outdoor canopies, cold storage facilities and manufacturing facilities. PRODUCT FEATURES: • Contoured component surfaces reduce the buildup of debris and permits easy cleaning • Hinged universal gear tray for trouble-free maintenance • Available with specular reflector as option. • Stainless steel cam-action latches come standard. Optional tamper proof screws available. • Universal mounting bracket included for surface and suspended mounting • The back of the housing has a 10 degree slope to satisfy the requirements in the food industry which are more stringent than NSF standards • Clear UV stabilized polycarbonate lens with linear pattern on perimeter • Comes standard with Advance high temperature Centium electronic MVOLT ballast (120/277) and a choice of 1 or 2 ballast configurations. (ICN-4S54-90C-2LS-G) HOUSING • Reinforced polyester compound • UL 5VA flammability • weatherability rated GASKETING Continuous Poured in place gasket seals off contaminants APPROVALS AND/OR LISTING • NSF Splash Zone 2 • IP67 • IP65 • Hose Down – 1300 PSI • NEMA-4X

Ordering Information Example: HD1B-4-54-T5ho

Hydro Beam Fluorescent 4 Lamp Hose Down High Bay

HD1B

4

54-t5ho

series

LAMPS

lamp type

HD1B Oracle Hydro Beam Wide Body

4

54-t5h0 - 54W T5HO

voltage2

(Blank) ADV-71 ADV-101

order code EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Essential2 Advance Rover2 Lutron Ecosystem H-Series2

WIRING options

-

Lutron Tu-Wire2

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

-

Lutron Ecosystem

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

MS - Motion Sensor

Lutron Eco-102

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

Lutron Tve2

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

LUT-EC31 -

2

LUT-H3D1

Lutron Hi-Lume 3D2

LUT-ECD1

Lutron Ecosystem (347V Only)2

1- Requires 2 Ballasts 2- Voltage must be specified for dimming ballast.

Standard Ballast info # of lamps F54T5H0 4

98

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102 Advance Optanium2

LUT-EHD1

LAMP

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

Description

ADV-ROVR1

ballast factor

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE 54w/T5HO

# of ballast

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

(Consult Factory for 208V, 248V, 347V and 480V wiring)

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

OTHER options

MSPH - Motion Sensor with Photocell WLMS - Wet Location Motion Sensor GSS - Gripple Suspension System VH - V Hook TPS - Tamper Proof Screws 4HD1BSR - Specular Reflector USA - Made in America Compliance

Min. Starting Temp (°F/°C) -20/ -29

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T5 HYDRO BEAM FLUORESCENT IP & NEMA RATED HIGH BAY WIDE BODY (6 LAMP T5)

HD1B

S H I P P I N G AVA I L A B L E

APPLICATION: Food processing facilities, sports complexes, warehouses, outdoor canopies, cold storage facilities and manufacturing facilities. PRODUCT FEATURES: • Contoured component surfaces reduce the buildup of debris and permits easy cleaning • Hinged universal gear tray for trouble-free maintenance • Available with specular reflector as option. • Stainless steel cam-action latches come standard. Optional tamper proof screws available. • Universal mounting bracket included for surface and suspended mounting • The back of the housing has a 10 degree slope to satisfy the requirements in the food industry which are more stringent than NSF standards • Clear UV stabilized polycarbonate lens with linear pattern on perimeter • Comes standard with Advance high temperature Centium electronic MVOLT ballast (120/277). (ICN-4S54-90C-2LS-G) and (ICN-2S54-90C) HOUSING • Reinforced polyester compound • UL 5VA flammability • weatherability rated GASKETING Continuous Poured in place gasket seals off contaminants APPROVALS AND/OR LISTING • NSF Splash Zone 2 • IP67 • IP65 • Hose Down – 1300 PSI • NEMA-4X

65,67

6-3/4" 17-1/4"

LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects.

51”

T5

Ordering Information Example: HD1B-6-54-T5ho 6

54-t5ho

series

LAMPS

lamp type

HD1B Oracle Hydro Beam Wide Body

6

54-t5h0 - 54W T5HO

voltage2

(Blank) ADV-71 ADV-101

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

order code

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Optanium2

-

Advance Essential2

ADV-ROVR

Advance Rover2

LUT-EHD1

Lutron Ecosystem H-Series2

WIRING options

-

Lutron Tu-Wire2

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

-

Lutron Ecosystem2

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

MS - Motion Sensor

Lutron Eco-102

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

-

Lutron Tve2

LUT-H3D1

Lutron Hi-Lume 3D2

LUT-ECD1

Lutron Ecosystem (347V Only)2

1- Requires 3 Ballasts 2- Voltage must be specified for dimming ballast.

Standard Ballast info # of lamps F54T5H0 6

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

Description

-

LUT-EC31

LAMP

ballast factor

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE 54w/T5HO

# of ballast

(Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts 120 277 347 480

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

(Consult Factory for 208V, 248V, 347V and 480V wiring)

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

WWW. ORACLELIGHTING . COM

SO1

OTHER options

MSPH - Motion Sensor with Photocell WLMS - Wet Location Motion Sensor GSS - Gripple Suspension System VH - V Hook TPS - Tamper Proof Screws 6HD1BSR - Specular Reflector USA - Made in America Compliance

Min. Starting Temp (°F/°C) -20/ -29

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

99

Hydro Beam Fluorescent 6 Lamp Hose Down High Bay

HD1B

HD1B


HD1B

T8 HYDRO BEAM FLUORESCENT IP & NEMA RATED HIGH BAY WIDE BODY (4 LAMP T8) S H I P P I N G AVA I L A B L E

65,67

6-3/4" 17-1/4"

51” T8H D1B

Ordering Information Example: HD1B-4-32-T8

Hydro Beam Fluorescent 4 Lamp Hose Down High Bay

HD1B

4

series

LAMPS

lamp type

HD1B Oracle Hydro Beam Wide Body

4

32-t8 - 32W/T8

APPLICATION: Food processing facilities, sports complexes, warehouses, outdoor canopies, cold storage facilities and manufacturing facilities. PRODUCT FEATURES: • Contoured component surfaces reduce the buildup of debris and permits easy cleaning • Hinged universal gear tray for trouble-free maintenance • Available with specular reflector as option. • Stainless steel cam-action latches come standard. Optional tamper proof screws available. • Universal mounting bracket included for surface and suspended mounting • The back of the housing has a 10 degree slope to satisfy the requirements in the food industry which are more stringent than NSF standards • Clear UV stabilized polycarbonate lens with linear pattern on perimeter • Comes standard with GE pro line multi-volt ballast (120/277) model number (GE432-MV-H). Also available with 2 GE432-MV-H ballast • CEE qualified ballast found standard on most fixture options (Consult factory for details). HOUSING • Reinforced polyester compound • UL 5VA flammability • weatherability rated GASKETING Continuous Poured in place gasket seals off contaminants APPROVALS AND/OR LISTING • NSF Splash Zone 2 • IP67 • IP65 • Hose Down – 1300 PSI • NEMA-4X LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects.

32-t8 voltage2

# of ballast

Description

order code

(Blank) EPS ADV-7 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Optanium2

ADV-ESS1

Advance Essential2

ADV-ROVR

Advance Rover

LUT-EHD1

Lutron Ecosystem H-Series2

2

LUT-2W1

Lutron Tu-Wire2

LUT-EC51

Lutron Ecosystem2

LUT-EC31

Lutron Eco-102

LUT-TVE

Lutron Tve

LUT-H3D1

Lutron Hi-Lume 3D2

-

WIRING options

2

Lutron Ecosystem (347V Only)

2

1- Requires 2 Ballasts 2- Voltage must be specified for dimming ballast.

100

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

Min. Starting Temp (°F/°C)

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

MS - Motion Sensor

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

Standard Ballast info

F32T8

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

32w/T8

1

# of lamps 4

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

emergency battery pack options (L. = Lumens)

BALLAST CONFIGURATION & CODE

LAMP

ballast factor

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

(Consult Factory for 208V, 248V, 347V and 480V wiring)

MSPH - Motion Sensor with Photocell WLMS - Wet Location Motion Sensor GSS - Gripple Suspension System VH - V Hook TPS - Tamper Proof Screws 4HD1BSR - Specular Reflector USA - Made in America Compliance

-22/ -30

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8 HYDRO BEAM FLUORESCENT IP & NEMA RATED HIGH BAY WIDE BODY (6 LAMP T8)

HD1B

S H I P P I N G AVA I L A B L E

APPLICATION: Food processing facilities, sports complexes, warehouses, outdoor canopies, cold storage facilities and manufacturing facilities. PRODUCT FEATURES: • Contoured component surfaces reduce the buildup of debris and permits easy cleaning • Hinged universal gear tray for trouble-free maintenance • Available with specular reflector as option. • Stainless steel cam-action latches come standard. Optional tamper proof screws available. • Universal mounting bracket included for surface and suspended mounting • The back of the housing has a 10 degree slope to satisfy the requirements in the food industry which are more stringent than NSF standards • Clear UV stabilized polycarbonate lens with linear pattern on perimeter • Comes standard with 2 GE Pro-Line MVOLT model number GE332-MV-H • CEE qualified ballast found standard on most fixture options (Consult factory for details). HOUSING • Reinforced polyester compound • UL 5VA flammability • weatherability rated GASKETING Continuous Poured in place gasket seals off contaminants APPROVALS AND/OR LISTING • NSF Splash Zone 2 • IP67 • IP65 • Hose Down – 1300 PSI • NEMA-4X LISTING - UL/ C-UL listed to US and Canadian standards. WARRANTY - Guaranteed for five years against mechanical defects.

65,67

6-3/4" 17-1/4"

51”

T8

Ordering Information Example: HD1B-6-32-T8 6

32-t8

series

LAMPS

lamp type

HD1B Oracle Hydro Beam Wide Body

6

32-t8 -32W T8

voltage2

BALLAST CONFIGURATION & CODE

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens) order code

(Blank) EPS ADV-7 ADV-101

Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

-

Advance Optanium2

ADV-ESS1

Advance Essential2

ADV-ROVR

Advance Rover

LUT-EHD1

Lutron Ecosystem H-Series2

LUT-2W

Lutron Tu-Wire

LUT-EC5

Lutron Ecosystem2

LUT-EC3

Lutron Eco-10

LUT-TVE1

Lutron Tve2

2

2

WIRING options

2

-

Lutron Hi-Lume 3D2

-

Lutron Ecosystem (347V Only)

2

Standard Ballast info

F32T8

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

Description

1- Requires 3 Ballasts 2- Voltage must be specified for dimming ballast.

# of lamps 6

ballast factor

32w/T8

1

LAMP

# of ballast

(Blank) - MVOLT (120/277) (Blank) -2 Ballast 3 -3 Ballasts 120 277 347 480

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

WWW. ORACLELIGHTING . COM

Min. Starting Temp (°F/°C)

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

MS - Motion Sensor

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

(Consult Factory for 208V, 248V, 347V and 480V wiring)

MSPH - Motion Sensor with Photocell WLMS - Wet Location Motion Sensor GSS - Gripple Suspension System VH - V Hook TPS - Tamper Proof Screws 6HD1BSR - Specular Reflector USA - Made in America Compliance

-22/ -30

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

101

Hydro Beam Fluorescent 6 Lamp Hose Down High Bay

HD1B

HD1B


4 lamp, t5 fluorescent IP & NEMA RATED high bay photometrics HD1B-4-54-t5ho lamp: PHILIPS F54T5/841/HO/ALTO 180

150

120

90

1183 60 2366

Lamp lumens: 4450

Zonal lumens summary zone lumens 0-30 5909.6 3,774.80 0-40 9307.6 6,303.20 0-60 17842.31 11,816.60 60-90 20439.92 5,522.10 o-90 20439.92 17,338.70

total luminaire efficiency: 88.5% spacing criteria: 1.10 candela tabulation

%lamp 24.3 19.30% 38.3 32.20% 65.2 60.30% 84.1 28.20% 84.1 88.50%

%fixt 28.9 20.80 45.5 34.70 6577.5 100 30.40 100 95.40

total luminiare efficiency = 88.5%

t5 fluorescent high bay

4731

0

efficiency = 88.5%

30

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0

4445 8687.6 4476 8652.8 4524 8388 4221 7793.2 3634 6796.9 2950 5511.9 2205 4159.7 1369 2663.8 594 1201.2 127 143.2 72 0

22.5

45

67.5

8687.6 4445 8669.6 4509 8372.6 4561 7461.9 4313 5722.7 3816 4003.1 3289 3098.7 2635 2214.8 1828 1122.6 1139 545476.9 4240

8687.6 4445 8685.2 4514 7876.4 4640 5791.3 4507 4888.1 4124 4302.6 3665 3588.9 3077 2176.8 2653 1613.7 1884 617.3 1211 0 1035

8687.6 4445 8669 4526 7121.7 4712 5408.2 4664 5114 4355 4658.1 3889 3338.1 3652 2258.3 3228 2093.2 2350 584.4 1677 0 1308

90 8687.6 4445 8619.5 4536 6815.9 4731 5435.4 4712 5138.1 4428 4621.1 3877 3183 3852 2419.7 3361 2207.6 2465 533.1 1805 0 1380

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 109 109 109 109 106 109 109 109 109 106 106 106 106 106 97 92 87 83 83 94 89 89 85 85 1 97 92 87 94 88 79 71 65 65 85 76 76 70 70 2 88 79 71 85 79 68 60 53 53 76 66 66 58 58 3 79 68 60 76 72 60 51 44 44 69 58 58 50 50 4 72 60 51 69 66 53 44 37 37 64 52 52 43 43 5 66 53 44 64 61 48 39 32 32 59 46 46 38 38 6 61 48 39 59 56 43 34 28 28 54 42 42 34 34 7 56 43 34 54 52 39 31 25 25 50 38 38 30 30 8 52 39 31 50 49 36 28 22 22 47 35 35 27 27 9 49 36 28 47 46 33 25 20 44 32 10 46 33 25 20 44 32 25 25 RC - Ceiling Cavity Reflectance RW - Wall Reflectance

50% 50% 30% 10% 101 101 101 101 101 101 84 81 81 77 84 77 72 67 67 62 72 62 63 56 56 51 63 51 55 48 48 42 42 55 49 42 42 36 36 49 44 37 37 31 31 44 40 33 33 27 27 40 37 29 29 24 24 37 34 27 27 22 22 34 31 24 20 31 24 20

10% 106 106 81 81 64 64 52 52 43 43 37 37 32 32 28 28 25 25 22 22 20 20

30% 50% 30% 10% 96 96 96 96 96 96 80 77 77 74 80 74 69 64 64 60 69 60 60 54 54 49 60 49 53 46 46 41 53 41 47 40 40 35 47 35 42 36 36 31 42 31 38 32 32 27 38 27 35 29 29 24 35 24 32 26 26 21 32 21 30 24 19 30 24 19

50% 91 91 76 76 65 65 57 57 50 50 45 45 40 40 37 37 34 34 31 31 29 29

10% 30% 10% 91 91 91 91 73 71 73 71 61 58 61 58 52 48 52 48 45 40 45 40 39 35 39 35 35 30 35 30 31 26 31 26 28 24 28 24 25 21 25 21 23 19 23 19

0% 0% 89 69 55 45 38 32 32 28 28 24 24 22 22 19 19 17 17

6lamp, t5 fluorescent IP & NEMA RATED high bay photometrics HD1B-6-54-t5ho lamp: PHILIPS F54T5/841/HO/ALTO 180

150

120

90

1543 60 3086

Zonal lumens summary zone lumens 0-30 5909.6 4,952.30 0-40 9307.6 8,257.30 0-60 17842.31 15,464.30 60-90 20439.92 6,398.50 o-90 20439.92 21,862.80

total luminaire efficiency: 74.4% spacing criteria: 1.16 candela tabulation

%lamp 24.3 16.80% 38.3 28.10% 65.2 52.60% 84.1 21.80% 84.1 74.40%

%fixt 28.9 21.60% 45.5 36% 77.5 67.40% 100 27.90% 100 95.30%

total luminiare efficiency = 74.4%

t5 fluorescent high bay

4629

6172

Lamp lumens: 4450

30

efficiency = 74.4%

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0 8687.6 5947 8652.8 6122 8388 5894 7793.2 5520 6796.9 4790 5511.9 3810 4159.7 2902 2663.8 1827 8411201.2 217143.2 1160

22.5 8687.6 5947 8669.6 6133 8372.6 5955 7461.9 5654 5722.7 5035 4003.1 4183 3098.7 3386 2214.8 2439 1122.6 1470 651476.9 5180

45 8687.6 5947 8685.2 6150 7876.4 6055 5791.3 5888 4888.1 5370 4302.6 4657 3588.9 4205 2176.8 3236 1613.7 2228 617.3 1242 0 969

67.5 8687.6 5947 8669 6166 7121.7 6139 5408.2 6049 5114 5609 4658.1 5158 3338.1 4751 2258.3 3676 2093.2 2634 584.4 1626 0 1141

90 8687.6 5947 8619.5 6172 6815.9 6161 5435.4 6094 5138.1 5676 4621.1 5297 3183 4868 2419.7 3782 2207.6 2735 533.1 1710 0 1169

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 112 100 100 98 92 92 92 100 92 89 98 89 9889 82 78 74 8070 80 85 76 8272 1 91 87 83 89 74 67 70 61 6556 72 74 65 6960 2 83 76 80 67 58 60 51 5446 65 65 57 5950 3 76 67 73 61 51 52 44 4638 59 58 50 5143 4 69 59 67 56 45 45 38 4032 54 52 44 4537 5 64 53 62 52 41 40 33 3528 50 47 40 4033 6 59 48 57 48 37 36 30 3125 46 43 36 3629 7 55 44 53 44 33 33 27 2822 43 39 33 3226 8 51 40 50 41 31 30 24 2519 40 36 30 3024 9 48 37 47 39 28 27 22 2318 38 33 28 2722 10 45 34 44 RC - Ceiling Cavity Reflectance RW - Wall Reflectance 102

10% 98 89 7869 6455 5445 4638 4032 3528 3124 2822 2519 2317

50% 50% 30% 10% 93 85 93 85 93 85 72 79 69 76 66 81 62 66 57 63 53 71 54 57 48 53 44 63 47 50 41 45 37 56 42 44 36 39 31 50 38 39 32 34 27 46 34 35 28 31 24 42 31 32 25 28 21 38 29 29 23 25 19 35 27 27 21 23 17 33

WWW.ORACLELIGHTING . COM

30% 50% 30% 10% 89 89 80 89 80 80 68 76 66 74 63 78 59 64 55 61 51 68 51 56 46 52 42 60 45 49 40 44 36 54 40 43 35 39 31 49 36 38 31 34 27 44 33 35 27 30 23 40 30 31 25 27 21 37 28 29 22 25 19 34 26 26 20 23 17 32

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

50% 86 76 65 75 56 66 49 58 43 52 38 47 35 43 32 39 29 36 27 33 25 31

10% 30% 10% 86 86 76 76 63 71 61 73 52 60 50 63 45 51 41 54 39 44 35 48 34 38 30 42 30 34 26 38 27 30 23 34 24 27 21 31 22 25 18 28 20 23 17 26

• FA X : 1 - 8 7 7 - 3 7 5 - 3333

0% 0% 84 74 59 70 48 58 39 49 33 42 28 36 24 32 21 29 19 26 17 23 15 21


4 lamp, t8 fluorescent IP & NEMA RATED high bay photometrics HD1B-4-32-t8 lamp: PHILIPS F32t8/tl24/plus/ALTO 180

150

120

90

640 60 1280

Lamp lumens: 2950

Zonal lumens summary zone lumens 0-30 5909.6 2,039.60 0-40 9307.6 3,402.40 0-60 17842.31 6,372.50 60-90 20439.92 2,593.80 o-90 20439.92 8,966.20

total luminaire efficiency: 76% spacing criteria: 1.10 candela tabulation

%lamp 24.3 17.30% 38.3 28.80% 65.2 54% 84.1 22% 84.1 76%

%fixt 28.9 21.30% 45.5 35.60% 77.5 66.60% 100 27.10% 100 93.70%

total luminiare efficiency = 76%

t8 fluorescent high bay

1920

2560

efficiency = 76%

30

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0

22.5

24536328.05 24756302.7 24496109.82 22405676.57 19554950.86 16094014.87 12243029.93 769 1940.31 323 874.95 66 104.31 37 0

6328.05 2453 6314.94 2478 6098.6 2469 5435.25 2289 4168.41 2048 2915.86 1752 2257.09 1433 1613.26 1015 547817.7 234347.37 1790

45

67.5

6328.05 2453 6326.3 2492 5737.17 2506 4218.38 2377 3560.49 2194 3134.01 1983 2614.15 1707 1585.58 1292 1175.42 897 449.64 481 0 400

6328.05 2453 6314.5 2498 5187.45 2542 3939.33 2452 3725.04 2328 3392.96 2117 2431.47 1899 1644.95 1538 1524.69 1073 639425.68 5240

90 6328.05 2453 6278.44 2499 4964.7 2555 3959.15 2477 3742.59 2376 3366.01 2201 2318.5 1962 1762.51 1612 1608.02 1122 388.31 691 0 559

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 100 100 100 98 95 95 95 100 95 93 98 93 9893 1 91 87 83 89 85 81 77 80 73 83 85 79 8275 77 70 70 63 65 58 74 74 68 6962 2 83 76 80 70 60 60 53 54 48 67 65 59 5952 3 76 67 73 64 53 52 46 46 40 61 58 52 5145 4 69 59 67 58 47 45 40 40 34 56 52 46 4539 5 64 53 62 54 42 40 35 35 29 52 47 41 4034 6 59 48 57 50 38 36 31 31 26 48 43 37 3630 7 55 44 53 46 35 33 28 28 23 45 39 34 3227 8 51 40 50 43 32 30 25 25 20 42 36 31 3025 9 48 37 47 40 29 23 18 39 29 2722 10 45 34 27 23 44 33 RC - Ceiling Cavity Reflectance RW - Wall Reflectance

50% 50% 30% 10% 93 87 93 87 93 87 81 74 79 71 76 68 64 66 59 63 55 71 56 57 50 53 45 63 49 50 43 45 38 56 44 44 37 39 33 50 39 39 33 34 28 46 36 35 29 31 25 42 32 32 26 28 22 38 30 29 24 25 20 35 27 22 18 33 27 23

10% 98 93 7872 6457 5447 4639 4033 3529 3125 2822 2520 2318

30% 50% 30% 10% 89 89 89 83 83 83 78 70 76 68 74 65 60 64 56 61 53 68 53 56 48 52 44 60 46 49 41 44 37 54 41 43 36 39 32 49 37 38 32 34 28 44 34 35 28 30 24 40 31 31 26 27 22 37 29 29 23 25 19 34 26 21 17 32 26 23

50% 86 78 75 66 57 66 50 58 44 52 39 47 36 43 32 39 30 36 27 33 25 31

10% 30% 10% 86 86 78 78 73 64 71 62 54 60 51 63 46 51 42 54 40 44 36 48 35 38 31 42 31 34 27 38 27 30 24 34 25 27 21 31 22 25 19 28 21 17 26 23

0% 0% 84 76 70 60 49 58 40 49 34 42 29 36 25 32 22 29 19 26 17 23 16 21

6 lamp, t8 fluorescent IP & NEMA RATED high bay photometrics HD1B-6-32-t8 lamp: PHILIPS F32t8/tl24/plus/ALTO 180

150

120

90

4027 60 3020

Lamp lumens: 2950

Zonal lumens summary zone lumens 0-30 5909.6 3,168.90 0-40 9307.6 5,262.60 0-60 17842.31 9,603.90 60-90 20439.92 3,399.20 o-90 20439.92 13,003.10

total luminaire efficiency: 73.5% spacing criteria: 1.16 candela tabulation

%lamp 24.3 17.90% 38.3 29.70% 65.2 54.30% 84.1 19.20% 84.1 73.50%

%fixt 28.9 23.20% 45.5 38.50% 77.5 70.20% 100 24.90% 100 95.10%

total luminiare efficiency = 73.5%

t8 fluorescent high bay

2014

1007

30

efficiency = 73.5%

ACROSS 45 ALONG

0 5 15 25 35 45 55 65 75 85 90

0 6328.05 3748 6302.7 3799 6109.82 3852 5676.57 3553 4950.86 3081 4014.87 2496 3029.93 1860 1940.31 1149 503874.95 87 104.31 39 0

22.5 6328.05 3748 6314.94 3809 6098.6 3892 5435.25 3632 4168.41 3217 2915.86 2695 2257.09 2131 1613.26 1429 806817.7 287347.37 1990

45 6328.05 3748 6326.3 3824 5737.17 3948 4218.38 3760 3560.49 3425 3134.01 2863 2614.15 2435 1585.58 1836 1175.42 1125 449.64 534 0 431

67.5 6328.05 3748 6314.5 3830 5187.45 4003 3939.33 3880 3725.04 3584 3392.96 2959 2431.47 2730 1644.95 2075 1524.69 1317 710425.68 5900

90 6328.05 3748 6278.44 3832 4964.7 4027 3959.15 3912 3742.59 3624 3366.01 3047 2318.5 2818 1762.51 2115 1608.02 1373 388.31 758 0 630

Room Cavity Ratio

Coefficients of Utilization - Zonal Cavity Method (Effective Floor Cavity Reflectance 0.20) RC 80% 70% RW 70% 50% 30% 10% 70% 50% 30% 0 100 100 100 98 91 91 91 100 91 89 98 89 9889 1 91 87 83 89 82 78 74 80 71 80 85 76 8273 74 67 70 62 65 57 72 74 66 6960 2 83 76 80 67 59 60 52 54 47 65 65 57 5951 3 76 67 73 62 52 52 45 46 39 59 58 51 5144 4 69 59 67 56 46 45 39 40 34 55 52 45 4538 5 64 53 62 52 41 40 34 35 29 50 47 40 4034 6 59 48 57 48 37 36 30 31 26 47 43 37 3630 7 55 44 53 45 34 33 27 28 23 43 39 33 3227 8 51 40 50 42 31 30 25 25 20 40 36 31 3024 9 48 37 47 39 29 27 22 23 18 38 33 28 2722 10 45 34 44 RC - Ceiling Cavity Reflectance RW - Wall Reflectance WWW. ORACLELIGHTING . COM

10% 98 89 7870 6456 5446 4639 4033 3529 3125 2822 2520 2318

50% 50% 30% 10% 93 84 93 84 93 84 81 72 79 69 76 67 62 66 58 63 54 71 54 57 49 53 45 63 48 50 42 45 38 56 43 44 37 39 32 50 39 39 33 34 28 46 35 35 29 31 25 42 32 32 26 28 22 38 29 29 24 25 20 35 27 27 22 23 18 33

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

30% 50% 30% 10% 89 89 89 79 79 79 78 68 76 66 74 64 59 64 55 61 52 68 52 56 47 52 44 60 46 49 41 44 37 54 41 43 36 39 32 49 37 38 32 34 28 44 34 35 28 30 24 40 31 31 26 27 22 37 28 29 23 25 20 34 26 26 21 23 18 32

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

50% 86 75 75 65 56 66 49 58 44 52 39 47 35 43 32 39 30 36 27 33 25 31

10% 30% 10% 86 86 75 75 73 63 71 61 53 60 51 63 46 51 42 54 39 44 36 48 35 38 31 42 31 34 27 38 28 30 24 34 25 27 21 31 23 25 19 28 21 23 17 26

103

0% 0% 84 74 70 59 49 58 40 49 34 42 29 36 25 32 22 29 20 26 18 23 16 21


HD2B

T5 HYDRO BEAM FLUORESCENT IP & NEMA RATED HIGH BAY (3 OR 4 LAMP T5HO) S H I P P I N G AVA I L A B L E

APPLICATION: The Hydro Beam Wet location high bay is ideal for food processing facilities, commercial kitchens, breweries, industrial facilities, parking garages, under awnings, laundries, utility tunnels, and car washes. PRODUCT FEATURES: • Exclusively designed around T5 lamps for superior light output. • Poured in place gasket and stainless steel latches seal the enclosures from most hostile environments. • Heavy duty diffuser resist breakage and ensure lamps are well protected to reduce maintenance. • Utilizes standard 1/2” fitting. • UV stabilized polycarbonate clear center lens with frosted ends. • Captive geartray operates from either side. • Optional highly tooled 95% reflective premium reflector material is engineered to optimize the thermal and luminous environment. • Using the latest optical technology our 4 lamp HD2B luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Comes standard with Advance high temperature Centium electronic MVOLT ballast (120/277) and a choice of 1 or 2 ballast configurations. (ICN-4S54-90C-2LS-G) • Suitable for suspension by Chain or cable.

65,66,67

5-15/16" 14-5/8"

51-15/16"

T5 HD2B

LISTING - UL Wet Location • NEMA 4X • IP65 • IP66 • IP67 • ROHS WARRANTY - Hydro Beam fixtures are warranted for ambient environments up to 55ºC for 5 years.

Ordering Information Example: HD2B-4-54-T5HO HD2B

54-t5ho voltage3

Hydro Beam Fluorescent 3 or 4 Lamp Hose Down High Bay

series

LAMPS

lamp type

HD2B Oracle Hydro Beam High Bay

3 4

54-t5h0 - 54W T5HO

BALLAST CONFIGURATION & CODE 54w/T5HO (Blank) ADV-71 ADV-101 ADV-ROVR LUT-EHD1

order code EMG-T5-T5HO-700

DESCRIPTION Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Rover

3

Lutron Ecosystem H-Series3 Lutron Tu-Wire3

-

Lutron Ecosystem3

-

WIRING options

Lutron Eco-103 Lutron Tve3

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

MS - Motion Sensor

LUT-H3D1

Lutron Hi-Lume 3D3

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

LUT-ECD1

Lutron Ecosystem (347V Only)3

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

Standard Ballast info # of lamps F54T5H0 3, 4

104

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1 98 10

Min. Starting Temp (°F/°C)

OTHER options

PCSB120

1- Requires 2 Ballasts for 3 or 4 Lamps. 2- Requires 2 Ballasts for 4 Lamps. 3- Voltage must be specified for dimming ballast.

LAMP

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

LUT-EC31

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

emergency battery pack options (L. = Lumens)

Advance Essential3 2

ballast factor

Description

Advance Optanium3

-

# of ballast

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

(Consult Factory for 208V, 248V, 347V and 480V wiring)

MSPH - Motion Sensor with Photocell WLMS - Wet Location Motion Sensor GSS - Gripple Suspension System VH - V Hook TPS - Tamper Proof Screws 4HD2BSR - Specular Reflector USA - Made in America Compliance

-20/ -29

WWW.ORACLELIGHTING .COM

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8 HYDRO BEAM FLUORESCENT IP & NEMA RATED HIGH BAY (3 OR 4 LAMP T8)

HD2B

S H I P P I N G AVA I L A B L E

APPLICATION: The Hydro Beam Wet location high bay is ideal for food processing facilities, commercial kitchens, breweries, industrial facilities, parking garages, under awnings, laundries, utility tunnels, and car washes. PRODUCT FEATURES: • Exclusively designed around T8 lamps for superior light output. • Poured in place gasket and stainless steel latches seal the enclosures from most hostile environments. • Heavy duty diffuser resist breakage and ensure lamps are well protected to reduce maintenance. • Utilizes standard 1/2” fitting. • UV stabilized polycarbonate clear center lens with frosted ends • Captive geartray operates from either side. • Optional highly tooled 95% reflective premium reflector material is engineered to optimize the thermal and luminous environment. • Using the latest optical technology our 4 lamp HD2B luminaire out performs conventional MH fixtures while maintaining minimal energy consumption. • Comes standard with GE pro line multi-volt ballast (120/277) model number (GE432-MV-H). Also available with 2 GE432-MV-H ballast. • Suitable for suspension by Chain or cable. • CEE qualified ballast found standard on most fixture options (Consult factory for details).

65,66,67

5-15/16" 14-5/8"

LISTING - UL Wet Location • NEMA 4X • IP65 • IP66 • IP67 • ROHS WARRANTY - Hydro Beam fixtures are warranted for ambient environments up to 55ºC for 5 years. 51-15/16"

T8

Ordering Information Example: HD2B-4-32-T8 HD2B

HD2B

32-t8 LAMPS

lamp type

HD2B Oracle Hydro Beam High Bay

3 4

32-t8 - 32W/T8

voltage3

# of ballast

BALLAST CONFIGURATION & CODE

emergency battery pack options (L. = Lumens) order code

(Blank) EPS ADV-7 ADV-102

Electronic Instant Start Electronic Program Start Advance Mark-73 Advance Mark-103

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

Advance Optanium3 Advance Essential3

ADV-ROVR

1

Advance Rover

3

LUT-EHD2

Lutron Ecosystem H-Series3

LUT-2W2

Lutron Tu-Wire3

LUT-EC52

Lutron Ecosystem3

LUT-EC32

Lutron Eco-103

LUT-TVE1

Lutron Tve3

LUT-H3D2 -

WIRING options

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

PCSB277

- 10’ Nema 7-15R 277V Straight Blade Plug

MS - Motion Sensor

Lutron Hi-Lume 3D3

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

Lutron Ecosystem (347V Only)3

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

1- Requires 2 Ballasts for 3 or 4 Lamps. 2- Requires 2 Ballasts for 4 Lamps. 3- Voltage must be specified for dimming ballast.

Standard Ballast info

F32T8

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

Description

ADV-ESS2

# of lamps 3, 4

lampS installed

(Blank)- High BF NBF- Normal BF LBF- Low BF

32w/T8

-

LAMP

ballast factor

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

Line Ballast Power THD% Factor Factor% (>=) (<=) volts 120/ 277 1.15 99 10

WWW. ORACLELIGHTING . COM

Min. Starting Temp (°F/°C)

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

(Consult Factory for 208V, 248V, 347V and 480V wiring)

MSPH - Motion Sensor with Photocell WLMS - Wet Location Motion Sensor GSS - Gripple Suspension System VH - V Hook TPS - Tamper Proof Screws 4HD2BSR - Specular Reflector USA - Made in America Compliance

-22/ -30

• TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5

• FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

105

Hydro Beam Fluorescent 3 or 4 Lamp Hose Down High Bay

series


T8 /T5 4’ VAPOR TIGHT, IP65 WET LOCATION LUMINAIRE (1 OR 2 LAMP)

OWVS

S H I P P I N G AVA I L A B L E

APPLICATION: The OWVS series is a wet location luminaire that is suitable for exposure to areas where water might be a hazard. Common applications include parking garages, schools, industrial facilities, and stairways.

65 2 Lamp

1 Lamp 4-1/3”

5”

PRODUCT FEATURES: • One piece fiber-glass housing with polycarbonate lens. • Easy install polycarbonate clips secure lens to housing and insure vapor tight operation. • Continuous one piece gasket assures airtight-seal keeping out condensation, humidity and dust, suitable for wet environments. • Shallow design is ideal for commercial and industrial spaces requiring general illumination. • Suitable for suspension by Chain or cable. Can also be surface mounted, all required hardware (less Chain, cable) is included. • Light weight design enables easier installation. • T8, T5 lampholders • Gear tray replaces full metal enclosure • CEE qualified ballast found standard on most fixture options (Consult factory for details). LISTING • UL/ C-UL listed to US and Canadian standards.

5-1/3”

• IP65 Rating. 6-5/8”

6-5/8”

50”

T8/T5 OWVS

WARRANTY - Guaranteed for one year against mechanical defects.

Ordering Information Example: 4-owvs-2-32-t8 4 FIXTURE SIZE

Wet Location 4’ Vapor Tight Fluorescent

4 - 4’

Owvs series

#LAMPS/LAMP TYPE

voltage1

1-32-T8 (1 lamp/32W/T8) 6 5/8in 2-32-T8 (2 lamps/32W/T8) 1-28-T5 (1 lamp/28W/T5) 2-28-T5 (2 lamps/28W/T5) 1-54-t5h0 (1 lamp/54W/T5HO) 2-54-t5h0 (2 lamps/54W/T5HO)

owvs-Oracle 6 5/8in Wet Location Vapor Tight

# of ballast

ballast factor

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

emergency battery pack options (L. = Lumens) order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

54w/T5HO

Description

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) ADV-7 ADV-10

-

ADV-OPT

-

Advance Optanium1

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

ADV-ESS

-

-

Advance Essential1

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ROVR

-

ADV-ROVR

LUT-EHD

LUT-EHD

LUT-EHD

Lutron Ecosystem H-Series1

WIRING options

LUT-2W

-

-

Lutron Tu-Wire1

- 10’ Nema 5-15R 120V Straight Blade Plug

LUT-EC5

LUT-EC5

-

Lutron Ecosystem1

PCSB120

- 10’ Nema 7-15R 277V Straight Blade Plug

LUT-EC3

LUT-EC3

LUT-EC3

PCSB277

LUT-TVE

-

-

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug - 10’ Nema L7-15R 277V Twist Lock Plug

LUT-H3D LUT-H3D -

-

Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

Advance Rover1

Lutron Eco-101 Lutron Tve1

LUT-H3D

Lutron Hi-Lume 3D

PCTL277

LUT-ECD

Lutron Ecosystem (347V Only)1

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

1

1- Voltage must be specified for dimming ballast.

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

OTHER options CH

- Heavy Duty Chain

MS

- Motion Sensor

MSPH GSS

- Motion Sensor with Photocell - Gripple Suspension System - Wet Location Motion Sensor

WLMS USA - Made in America Compliance

(Consult Factory for 208V, 248V, 347V and 480V wiring)

106

W W W. O R AC L E L I G H T I N G . C O M

• TEL: 1-877-375-5555

• FA X : 1 - 8 7 7 - 3 7 5 - 3333


T8 /T5 8’ VAPOR TIGHT, IP65 WET LOCATION LUMINAIRE (1 OR 2 LAMP 8’) OR (2 OR 4 LAMP 8’ TANDEM)

OWVS

S H I P P I N G AVA I L A B L E

APPLICATION: The OWVS series is a wet location luminaire that is suitable for exposure to areas where water might be a hazard. Common applications include parking garages, schools, industrial facilities, and stairways. PRODUCT FEATURES: • One piece fiber-glass housing with polycarbonate lens. • Easy install polycarbonate clips secure lens to housing and insure vapor tight operation. • Continuous one piece gasket assures airtight-seal keeping out condensation, humidity and dust, suitable for wet environments. • Shallow design is ideal for commercial and industrial spaces requiring general illumination. • Suitable for suspension by Chain or cable. Can also be surface mounted, all required hardware (less Chain, cable) is included. • Light weight design enables easier installation. • T8, T5 lampholders • Gear tray replaces full metal enclosure • CEE qualified ballast found standard on most fixture options (Consult factory for details).

65 2 Lamp

1 Lamp

LISTING • UL/ C-UL listed to US and Canadian standards.

4-1/3”

5”

5-1/3”

• IP65 Rating. 6-5/8”

6-5/8”

WARRANTY - Guaranteed for one year against mechanical defects.

98”

T8/T5

Ordering Information Example: 8-owvs-2-32-t8-mvolt 8

OWVS

Owvs series

#LAMPS/LAMP TYPE

8 - 8’

owvs-Oracle Wet Location Vapor Tight

1-59-T8 (1 lamp/59W/T8) 2-59-T8 (2 lamps/59W/T8) 8’ TANDEM fixtures 2-32-T8 (2 lamps/32W/T8) 4-32-T8 (4 lamps/32W/T8) 2-28-t5 (2 lamps/28W/T5) 4-28-T5 (4 lamps/28W/T5) 2-54-T5HO (2 lamps/54W/T5HO) 4-54-t5hO (4 lamps/54W/T5HO)

voltage2

BALLAST CONFIGURATION & CODE 32w/T8

59w/T8

28w/T5

(Blank) EPS ADV-7 ADV-101

(Blank) EPS -

(Blank)1 -

54w/T5HO (Blank) ADV-71 ADV-101

-

-

ADV-OPT

-

# of ballast

Description Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102

lampS installed

ballast factor

(Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480

(Blank)- Normal BF HBF- High BF LBF- Low BF

6 5/8in(blank) - No lamps L30K - 3000K 6 5/8in L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens) order code EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

Advance Optanium2

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

Advance Essential2

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

ADV-ESS1

-

-

ADV-ROVR

-

-

LUT-EHD1

-

LUT-EHD1

LUT-EHD1

Lutron Ecosystem H-Series2

WIRING options

LUT-2W1

-

-

-

Lutron Tu-Wire2

- 10’ Nema 5-15R 120V Straight Blade Plug

-

LUT-EC51

-

Lutron Ecosystem2

CH

- Heavy Duty Chain

LUT-EC51

PCSB120

- 10’ Nema 7-15R 277V Straight Blade Plug

-

LUT-EC31

LUT-EC31

MS

- Motion Sensor

LUT-EC31

PCSB277

LUT-TVE1

-

-

-

PCTL120

- 10’ Nema L5-15R 120V Twist Lock Plug

MSPH

LUT-H3D1

-

LUT-H3D1

LUT-H3D1

Lutron Hi-Lume 3D2

PCTL277

- 10’ Nema L7-15R 277V Twist Lock Plug

GSS

-

-

-

LUT-ECD1

Lutron Ecosystem (347V Only)2

IPTL120

- 10’ 120V IP Rated Twist lock Plug

IPTL277

- 10’ 277V IP Rated Twist lock Plug

ADV-ROVR1 Advance Rover2

1- Requires 2 Ballasts for 4 lamps. 2- Voltage must be specified for dimming ballast.

Lutron Eco-102 Lutron Tve2

SO1

- 10’ 120V/277V SO Cord

SO2

- 10’ 480V SO Cord

OTHER options

WLMS

- Motion Sensor with Photocell - Gripple Suspension System - Wet Location Motion Sensor

USA - Made in America Compliance

(Consult Factory for 208V, 248V, 347V and 480V wiring)

WWW.ORAC L E L I G H T I N G . C O M

• TEL: 1-877-375-5555

• FA X : 1 - 8 7 7 - 3 7 5 - 3 3 3 3

107

Wet Location 8’ Vapor Tight Fluorescent

FIXTURE SIZE


T8 /T5 2’ & 4’ VAPOR TIGHT, IP65 WET LOCATION LUMINAIRE (1 OR 2 LAMP)

OW1IP

S H I P P I N G AVA I L A B L E

APPLICATION: The OWIP series is suitable for wet location areas. Common applications include parking garages, schools, industrial facilities, and stairways. PRODUCT FEATURES: • Suitable for suspension by Chain, cable or pendant. Can also be surface mounted. All required hardware and mounting brackets are included. Suspension systems are not included. Chain or stainless steel cable are available as options . • Integral Molded Latch retention pockets securely locks in polycarbonate latches. Stainless steel latches available upon request. STRUCTURALLY RIGID FIBERGLASS BODY • Fiberglass is reinforced polyester and self-extinguishing (ASTM D63574). This type of construction does not allow the body to flex during handling and installation. GASKETED DIFFUSER RETENTION SLOT • The gasketed inverted U-slot provides a positive continuous seal between body and diffuser. • Continuous poured gasket completely fills channel for maximum seal integrity HIGH IMPACT ACRYLIC/DR DIFFUSER • Internal crepe pattern allows a smooth exterior surface for ease of cleaning. • The diffuser flange fits snugly into the gasketed retention slot forming a continuous seal. • Optional 95% reflective silver reflector. (See Gear tray on page 112) • CEE qualified ballast found standard on most fixture options. LISTING • UL/ C-UL listed to US and Canadian standards.

65 4-7/8” 6-5/8”

26”

OW1IP

• IP65 Rating. (See accessories on page 112)

50”

T8/T5

WARRANTY - Guaranteed for one year against mechanical defects.

Ordering Information Example: 4-ow1ip-2-32-t8 Ow1IP

Wet Location 4’ Vapor Tight Fluorescent

FIXTURE SIZE

series

#LAMPS/LAMP TYPE

2 - 2’ 4 - 4’

ow1IPOracle Wet Location Vapor Tight

2’ fixture 1-17-T8 (1 lamp/17W/T8) 2-17-T8 (2 lamps/17W/T8) 1-14-T5 (1 lamp/14W/T5) 1-24-T5HO (1 lamp/24W/T5HO) 2-14-T5 (2 lamps/14W/T5) 2-24-T5HO (2 lamps/24W/T5HO) 4’ Fixture 1-32-T8 (1 lamp/32W/T8) 2-32-T8 (2 lamps/32W/T8) 1-28-T5 (1 lamp/28W/T5) 2-28-T5 (2 lamps/28W/T5) 1-54-t5h0 (1 lamp/54W/T5HO) 2-54-t5h0 (2 lamps/54W/T5HO)

voltage1

ballast factor

lampS installed

(Blank)- Normal BF HBF- High BF LBF- Low BF

(blank) - No lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K

emergency battery pack options (L. = Lumens) order code

BALLAST CONFIGURATION & CODE 32w/T8

28w/T5

17w/T8

54w/T5HO

14w/T5

(Blank) EPS ADV-7 ADV-10

(Blank) -

(Blank) EPS ADV-7 ADV-10

(Blank) ADV-7 ADV-10

(Blank) -

(Blank) ADV-10

-

ADV-OPT

-

-

-

-

Advance Optanium1

ADV-ESS

-

ADV-ESS

-

-

-

Advance Essential1

ADV-ROVR

-

24w/T5HO Description Electronic Instant Start Electronic Program Start Advance Mark-71 Advance Mark-101

EMG-T8-BX-450

DESCRIPTION Up to 450 L. for T8 or BX

EMG-T8-BX-600

Up to 600 L. for T8 or BX

EMG-T8-BX-700

Up to 700 L. for T8 or BX

EMG-T8-BX-1400

Up to 1400 L. for T8 or BX

EMG-T5-T5HO-700

Up to 700 L. for T5 or T5HO

EMG-T5-T5HO-1300

Up to 1300 L. for T5 or T5HO

EMG-T8-BX-T5-T5HO-3200

Up to 3200 L. for T8, bx, T5 or T5HO

EMG-SD-T8-BX-T5-T5HO-1400

Self-Diagnostic 1400 L. for T8, bx, T5 or T5HO

EMG-ICE-T8-BX-T5-T5HO-1400

ICE Pack 1400 L. for T8, bx, T5 or T5HO

WIRING options

OTHER options

PCSB120

- 10’ Nema 5-15R 120V Straight Blade Plug

CH - Heavy Duty Chain

PCSB277